1. Step 6 Connect an AC DC power adapter to the DC input terminal either of Transmitter and Receiver boxes as your availability of AC outlets Figure 5 Connection of AC DC power adaptor Step 7 Plug the AC DC power adapter into AC outlet Turn ON the PC Tip 1 After initial installation as guided in the above we recommend you to power On and Off while all connections are set and the Tx Rx boxes are powered in 1 4 Installation continued Installation Virtual DDC Use this menu without DDC through CAT5e Important Please use the installation procedure below Improper or no operation may result if the start up sequence is not correctly followed Step 1 Check that the transmitter and receiver are turned off Set DDC connection switch to Virtual DDC position on the front panel of the transmitter Step 2 For Self EDID programming a Plug the 24V power adapter to the power jack of the transmitter and connect the adapter into AC outlet Ensure Power and Virtual DDC LEDs are turned ON b Push the Self EDID button on the front side of Tx box The Virtual DDC LED is turned ON after blinking twice The Status LED is turned ON Note Please DO NOT connect the Tx to the display without pushing the Self EDID button The display may be damaged by unnecessary power supply through pin16 of DVI connector c Connect the powered transmitter to the powered display through DV
2. 24 V and outer cylinder is GND Length is 18 5 cm AC Cord length 1 8m Certification PSE UL cUL FCC CE TUV GS UL 1 8 Product Specifications Warranty Information 1 One Year Warranty Opticis warrants this optical dual link DVI module to be free from defects in workmanship and materials under normal use and service for a period of one 1 year from the date of purchase from Opticis or its authorized resellers If a product does not work as warranted during the applicable warranty period Opticis shall at its option and expense repair the defective product or part deliver to customer an equivalent product or part to replace the defective item or refund to customer the purchase price paid for the defective product All products that are replaced will become the property of Opticis Replacement products may be new or reconditioned Any replaced or repaired product or part has a ninety 90 day warranty or the reminder of the initial warranty period whichever is longer Opticis shall not be responsible for any software firmware information or memory data of customer contained in stored on or integrated with any products returned to Opticis for repair under warranty or not Warranty Limitation and Exclusion Opticis shall have no further obligation under the foregoing limited warranty if the product has been damaged due to abuse misuse neglect accident unusual physical or electrical stress unauthorized modific
3. America cUL or CSA for Canada TUV CE amp GS for EU and PSE for Japan Certification of Eye Safety This laser product is inside implemented by using 1310 1550nm LD Transceivers manufactured by Opticis Co Ltd which are all certified by CDRH FDA referred as classified in Laser Class 1 1 10 Regulatory Statements 2008 Opticis Co Ltd All Rights Reserved Revision 1 0 MAY 2008 Opticis Locations Opticis Co Ltd 501 Byucksan Technopia 434 6 Sangdaewon Dong Chungwon ku Sungnam City Kyungki Do 462 120 South Korea Tel 82 31 737 8033 Fax 82 31 737 8079 For order support please contact your Distributor or Reseller For technical support check with the with the Opticis web site www opticis com or contact techsupport opticis com
4. system It should support the maximum graphic resolution feature of the display to be connected m In case of using a computer no special memory size CPU speed and chipsets are required Proper initial trial of the entire platform with its application using a short length copper cable is recommended prior to install with the optical link O Software requirements m No special needs if the Dual link graphic controller and display peripheral are operational with the platform s OS and application O AC DC Power Adapter Technical Advisory Direct DDC One power adaptor is required to supply power to both modules of Tx and Rx over the CAT5e cable by plugging the power jack to either of their power plugs Virtual DDC Two power adapters are required to supply power to Tx and Rx module due to no use of the CAT5e cable for DDC es Se e DVI DUAL LINK i INPUT PC OUTPUT Display DVI DUAL LINK Up to 100m with DDC2B 2km with virtual DDC Figure 1 Overall Optical dual link DVI Module 1 2 System Requirements for Setup Installation Direct DDC Use this menu when DDC through CAT5 Important Please use the installation procedure below Improper or no operation may result if the start up sequence is not correctly followed Step 1 Check that the transmitter and receiver are turned off Set DDC connection switch to Direct DDC position on the front of the transmitter Step 2 Connect t
5. I dual link cable not to the PC The LED blinking for 8 10 seconds indicates reading the EDID data Virtual DDC LED is turned OFF after blinking and programming is done a Pn E 2a An ji L OA Wes ot Pee 4 kB Sy oe weed DVI DUAL LINK OUTPUT Display Figure 6 Connection for Self EDID programming d Disconnect the transmitter from the display and the power adapter Note If you want to change the display please do again the step 2 The EDID factory default is programmed with the VESA standard of WQXGA 2560x1600 60Hz 1 5 Installation continued Step 3 Check that the transmitter and receiver are turned off and connect the upstream Transmitter box to the DVI receptacle of PC by one dual link DVI copper cable in the shipping group Step 4 In the same way as above connect the Receiver box into the DVI receptacle of the display by the other dual link DVI copper cable Step 5 Remove the module dust covers and connect each duplex LC fiber cable one by one to each of 2 LC duplex receptacles of the Transmitter and Receiver boxes as shown in Fig 7 Plug channel 1 to 1 and channel 2 to 2 Carefully recheck polarities and ensure the duplex connectors are fully engaged DVI DUAL LINK DVI DUAL LINK INPUT PC OUTPUT Display Figure 7 Connection of 4 LC fiber cables Note Connection for single link DVI For single link DVI use one duplex fiber or two simplex fibers is required to be plugged to one
6. Manual Contents Manual Contents Welcome Product Description System Requirements for Setup Installation Direct DDC Ti C l S Installation Virtual DDC D l Troubleshooting Maintenance Technical Support Product Specifications Warranty Information Regulatory Statements Pictorials Op tical D Vi Dual Link Figure 1 Overall Optical DVI Module _ Extension Module Figure 2 Connection of DVI cable between Transmitter box and PC Figure 3 Connection of DVI cable between Receiver box and the display Figure 4 Connection of 4 LC fiber cables and a DDC cable Figure 5 Connection of AC DC power adaptor User s Man ual Figure 6 Connection for Self EDID programming Figure 7 Connection of 4 LC fiber cables for the M 1 3R2 Vi DU Figure 8 Connection of AC DC power adaptor pA TOn CE f aA o Che Swit 1 0 Manual Contents 1 0 1 1 1 2 1 3 1 5 1 7 1 8 1 9 1 10 1 2 1 3 1 3 1 4 1 5 1 6 1 6 Welcome Congratulations on your purchase of the M1 3R2VI DU Optical Dual Link DVI Module This manual contains information that will assist you in installing and operating the product Product Description The M1 3R2VI DU module offers 100meters extension of dual link high resolution digital graphic data over fiber directly connected between PC and displays supporting dual link DVI Two boxes located one by the PC and the other by the display are connected to each of t
7. ations tampering alterations or service other than by Opticis or its authorized agents causes other than from ordinary use or failure to properly use the product in the application for which said product is intended Dispose of Old Electrical amp Electronic Equipment Applicable in the European Union and other European countries with separate systems This symbol on the product or on its packaging indicates that this product shall not be treated as household waste Instead it shall be handed over to the applicable collection point for the recycling of electrical and electronic equipment By ensuring this product is disposed of correctly you will help prevent potential negative Ea consequences for the environment and human health which could otherwise be caused by inappropriate waste handling of this product The recycling of materials will help to conserve natural resources For more detailed information about recycling of this product please contact your local city office your household waste disposal service or the shop where you purchased the product 1 9 Warranty Information FCC CE Statement for regulation of Electro magnetic emission This device complies with part 15 of FCC Rules Operation is subject to the following two conditions 1 this device may not cause harmful interference and 2 this device must accept any interference received including interference that may cause undesired operation This equipment has been t
8. ested and found to comply with the limits for a Class B digital device pursuant to part 15 and 2 of FCC Rules EN 55022 55024 61000 3 for CE certification These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a residential installation This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instruction guide may cause harmful interference to radio communications However there is no guarantee that interference will not occur in a particular installation If this equipment does cause harmful interference to radio or television reception which can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one or more of the following measures e Re orient or relocate the receiving antenna e Increase the separation between the equipment and the receiver e Connect the equipment into an outlet on a circuit different from that to which the receiver is connected e Consult a service representative for help Properly shielded and grounded cables and connectors must be used in order to comply with FCC CE emission limits Changes or modifications not expressly approved by the party responsible for compliance could void the user s authority to operate the equipment Certification for Safety The AC DC power adapter is certified by UL1310 1950 60950 for North
9. he upstream Transmitter box to the DVI receptacle of PC through one dual link DVI copper cable included DVI DUAL LINK INPUT PC Figure 2 Connection of DVI cable between Transmitter box and PC Step 3 In the same way as above connect the Receiver box into the DVI receptacle of the display through the other dual link DVI copper cable AA D een ES a i 7 a F NTI F DVI DUAL LINK OUTPUT Display Figure 3 Connection of DVI cable between Receiver box and the display Warning Please DO NOT look directly into the LC receptacles of the Transmitter box while it is turned on although this product is strictly regulated enough to operate under the Laser Class I classified by CDRH FDA for eye safety 1 3 Installation Step 4 Remove the module dust covers and connect each duplex LC fiber cable one by one to each of 4 LC receptacles of the Transmitter and Receiver boxes as shown in Fig 4 Plug channel 1 to 1 and channel 2 to 2 Carefully recheck polarities and ensure the duplex connectors are fully engaged Step 5 Connect each RJ 45C of the CAT5e cable to each RJ 45C receptacle of the Transmitter and Receiver boxes DVI DUAL LINK DVI DUAL LINK INPUT PC OUTPUT Display Figure 4 Connection of 4 LC fiber cables and a DDC cable Note Connection for single link DVI For single link DVI use one duplex fiber or two simplex fibers are required to be plugged to one port marked Channel 1
10. hem with a 1 0 m dual link DVI copper cable Between two boxes 7 channels R G B Clk R2 G2 B2 of graphic data enables to be transmitted over the 4 LC single or multi mode fiber bundled cable and the Digital Display Channel DDC2B interface is performed over a CAT5e cable so called as DDC cable which has RJ 45C connectors The M1 3R2VI DU also provides 2km extension over 4 single mode fibers using virtual DDC mode without CAT5e connection The EDID Extended Display Identification Data in a display can be read and restored by just plugging once transmitter to the display This Self EDID programming feature makes the installation of M1 3R2VI DU easier and more flexible at any variable resolution display systems For your convenience Factory EDID default is set to WQXGA 2560x1600 Shipping Group of M1 3R2VI DU Optical Dual Link DVI Module 1 Tx and Rx boxes One 1 Transmitter Tx Box and One 1 Receiver Rx Box Two 2 dual link DVI copper cables 1 0m AC DC power adapter One 1 24V unit User s Manual Option DDC cable UTP for LAN with RJ 45C Option 4 LC Patch Cord fiber bundled cable Single or Multi mode glass fiber Option Two 24V AC DC power adapters are required for virtual DDC Oo oo g O 1 1 Welcome Product Description System Requirements for Setup O Hardware requirements m You have a Media Receiver or a graphic controller card with a Dual link port in your Windows Mac Mac is option or SUN
11. ion There are no user serviceable parts Refer all service and repair issues to Opticis or its authorized distributor Technical Support and Service For commercial or general product support contact your reseller For technical service contact Opticis by email techsupp opticis com or visit its website at www opticis com 1 7 Troubleshooting Maintenance Technical Support Product Specifications M1 3R2VI DU Optical Dual Link DVI Module O Fully backward compatible with DVI standard supports DVI 1 0 using fiber optic communication links and DDC2B O Extension limit 100m 330feet for 2 560x1 600 1 65Gbps with Direct DDC 2km 6 560feet for 2 560x1 600 1 65Gbps with Virtual DDC O Graphic Transmission Bandwidth supports up to 1 65Gbps bandwidth per graphic channel O Fiber optic Connection The transmitter and receiver boxes of M1 3R2VI DU have 2 duplex LC receptacles connected to four 4 9 8 125um Single Mode or 62 5 50 125um Multi Mode glass fibers cables O Mechanical specifications of Tx and Rx boxes m Dimensions 216mm 31mm 112mm W H D Weight 380 20 gr for each of Tx and Rx O Environmental Specifications m Operating temperature 0 C to 50 C m Storage temperature 10 C to 85 C Mm Humidity 5 to 85 AC DC Power Adapter O Power Input Universal AC 85 264V 50 60Hz AC power cord with power jack O Power Output 24 V 2 5 A SMPS DC power Adapter O Cord DC Jack amp length Core is
12. port marked Channel 1 Note that self EDID programming is also applicable in connection for single link DVI Step 6 Connect two AC DC power adapters to each of the DC input terminals of the Transmitter and Receiver boxes Figure 8 Connection of AC DC power adaptor Step 7 Plug the AC DC power adapter into AC outlet Turn ON the PC Tip 1 After initial installation as guided in the above we recommend you to turn On and Off PC while all connections are set and the Tx Rx boxes are powered in 1 6 Installation continued Troubleshooting The display displays only black screen e Check that all AC and DC plugs and jacks used by external power supplies both Opticis and others are firmly connected e Ensure that power is turned on e Ensure that the Tx and Rx boxes plug correctly to the PC and display respectively e Check if the PC and display are powered on and properly booted e Re boot up the system after reconnecting the optical system cable Screen is distorted or displays noises e Reset the system e Turn off disconnect the LC LC fiber cable and try to blow inside of each LC receptacle by air blower e Reconnect the fiber cable and turn on e f noise continues please contact the following Maintenance No special maintenance is required for the optical system cables and power supplies Ensure that the cables and power modules are stored or used in a benign environment free from liquid or dirt contaminat