Home
User manual
Contents
1. 11 27 Tel 91 95 03487924 E mail _dev kanha8 amp 6 ail com OSMO Cr Turn it then the water cycles inside and the interface shows like this OSMO 91 95 03 487924 Turn off the machine PS this is to make sure water cycles normally only when it cycles normally can the machine work in stable state You will hear the sound of water flow 3 5 minutes later the probe runs cold If the water doesn t cycle or the probe does not cold there might be air in the pump Grip the white hose vertically and slack then turn on the device again this will exhaust the air to the water tank then the air will exhaust from the hole for spilt water and water inlet Tel 91 95 03487924 uev kanha86 gmail com OSMO as ECHe g How to insert the filter Please make sure the filter is clean Use even force to insert it into the slot There is a counter which many shots has shows how handle side a been used N J JER You can press either of this button to let the shot out Or use the pedal The above is the Newest Handle design very elegant Tel 91 95 03487924 E mail dev kanha86 ail com CT Chapter 4 How to use E angel 301 I Clinic operation Before the treatment a Classification of skin it s safe and effective to the white brown or yellow skin b Sign the agreement c Clean the skin to make sure there is no perfume and cosmet
2. That will make skin gets different energies which will sure hurt the customer f If you want to slide to another far away parts of skin pls release the button or the foot pedal first This can avoid customers hurt by sudden shock I a Before and after the treatment please Avoid sunlight and burn and you need to use some UV power protector cream SPF gt 30 to avoid direct sunshine b One week before and after the treatment Please do Avoid chemical or mechanical stimulation c 2 weeks before and after the treatment Do not take filled things or injection treatment d 3 days after treatment Avoid direct or indirect heat stimulation to the treatment area especially to those of high pigment deposit e If the customer had laser skin care treatment before this treatment please wait for more than 3 weeks then the customer can accept the treatment f After the treatment patients are not allowed to eat the foods of dark color or very spicy food within two weeks such as the sauce coke sea foods capsicum etc g It s not allowed that insolation in the sun before and after the treatment h Its not allowed to use any cosmetics after the treatment it is advised to use natural moisturize products i Please cool the bad reaction area like tumescence and causalgiase after the treatment with small pieces of ice 15 27 Tel 91 95 03487924 E mail dev kanha86 ail com OSMO Cr t ECHe Il Parameters of each treatment
3. inflamed feelings on skin Lightly tweezer the hair root naturally shed and no pain which means the best effect eParameters Discharge interval 4 pulse 6 7 6 8 2 5 0 LI LU 12 12 Discharge interval 4 pulse 6 7 8 8 4 5 0 12 12 17 27 Tel 91 95 03487924 E mail dev kanha86 ail com OSMO Cr Discharge interval 4 pulse 6 8 0 8 6 5 0 12 12 maer Arms gt i i i 7 Yer i T eZ FAG gt y l belori A A A er E E m eer AT o CN A After T z Bettors Theesen After 2 Teiresias b skin rejuvenation treatment 530nm 1200nm filter FiMILaD with hair removal treatment Ps you don t need to cut hair before the treatment as that is for hair removal treatment only e1 3 or 3 6 treatments as one cycle eEvery 3 4 weeks for one treatment U Because the human metabolism cycle is 3 4 weeks the stimulated collagen fiber tissues and flexibility fiber tissues will be steady along with the metabolism ecooling gel customer will feel less painful and the cooling gel can better lead light to skin eParameters Discharge interval 3 pulse ff 4 7 2 7 5 5 0 LI LU 10 10 Discharge interval 3 pulse 4 7 4 7 7 5 0 LI LU 10 10 18 27 Tel 91 95 03487924 OSMO CT Discharge interval 3 pulse ff 4 7 6 7 9 5 0 7milad with hair removal treatment Ps you don t need to cut hair before the treatment as that is for hair removal treatment
4. treatment of the skin in a process known as photorejuvenation The focused broad spectrum light is applied to the surface of the skin by way of either a hand held wand or an articulated arm This light travels through the skin until it strikes the hair shafts or the bulb root of the hair The bulb is usually where the highest concentration of melanin is located as opposed to the rest of the hair shaft As the light is converted to heat energy the bulb and most of the hair shaft are instantly vaporized The intense heat radiated by the hair also destroys the hair producing papilla or the entire hair follicle It is also claimed that direct light heat conversion occurs directly in the darker colored capillaries that bring nourishing blood to the follicle IPL technology is also employed in the treatment of medical disorders of the skin including e Sun damage induced dyspigmentation and vascular changes e Poikiloderma of Civatte e Acne Rosacea e Broken capillaries telangiectases e Vascular and pigmented birth marks In terms of rosacea IPL offers one of the few effective treatments to relieve the facial redness associated with the disorder Such treatment is best administered by a specialist dermatologist This new technology incorporates dual mode filtering and other important advances which result in safer and more effective treatment than older systems designed for hair removal 3 27 Tel 91 95 03487924 E mail _dev kanha86 ail
5. OSMO 91 95 03 487924 DEN we have set these parameters for you already so that really saves time for you you don t need to set those parameters each time you have customers You just adjust the IPL and RF energy and the cooling mode and you can start the treatment Clean the customer s skin with water shave the unwanted hair on the treatment area or shear the unwanted hair till 1mm to the hair root 16 27 Tel 91 95 03487924 E mail _dev kanha amp 6 ail com Gz Oon gel is used to let customers skin feel cold and better lead light into deep layer of skin Spread the cooling gel on the treatment area about 3mm thickness During the process of parameter adjustment or parameter settings don t touch Ready you can press it when you finished setting the parameters Please screw on the 2 caps of water inlet and spilt water wait for 20 minutes then scrape the cooling gel a hair removal treatment 640nm 1200nm filter AMILO with hair removal treatment Ps you don t need to cut hair before the treatment as that is for hair removal treatment only e 3 5 treatments as one cycle e Every 3 4 weeks for one treatment a 7 Because human metabolism cycle is 3 4 weeks some decomposed pigment cells of hair follicle are phagocytosed by the lymphocyte and expel from the body along with metabolism eFeelings in the treatment some pain feelings like needle pricking 3 8 hours after the treatment a little
6. Safe power line designed with 3 cores 1 a The temperature of objects will rise after absorbing light energy so please take actions to reduce the flammable risk on treatment areas and surrounding areas b Do not use alcohol acetone or other flammable things on skin before treatment You can just wash the skin with water or sometimes a little soap c If you use alcohol to disinfect the treatment head or any other parts please wait till dry and then start the machine otherwise it is dangerous 2 SYSTEM SAFETY SETTINGS a Everybody in the operation room must know where the safety sets are and how to use them b Anybody who doesn t have our key is not able to start the machine c There is a red indicator light which will be on if you start the machine d Emergency button the red switch is used to switch off power when you come to any emergency Just press it and the machine will stop working next time you use the machine you need to turn this emergency button on 6 27 Tel 91 95 03487924 E mail _dev kanha8 amp 6 ail com 3 KAUTOMATICAL INSPECTION It will start inspecting itself automatically when you start the machine You need to turn on and turn off the machine repeatedly for 3 times and then start using it 4 LEVEL OF EQUIPMENT a Level of motor protection 1 CLASS BF CLASS Anti corrosive liquid general O o Not allowed to use this machine in room that exists flammable anesthetic and nitrous oxid
7. User manual IPL Model No E angel 301 Catalog Chapter 1 Introduction of E angel 301 I Treatment theory II Functions of E angel 301 II Taboos Chapter 2 Safety notices of E angel 301 I IPL safety notices Il Warning M Main warning Chapter 3 Installation of E angel 301 I Components of the device II How to install this machine Chapter 4 How to use E angel 301 I Clinic operation II Parameters of each treatment Chapter 5 Simple Maintenance of E angel301 I Precautions II Analysis on Simple Malfunction Chapter6 Contact us 2 27 Tel 91 95 03487924 E mail dev kanha86 ail com Chapter 1 Introduction of E angel 301 I Treatment theory Intense Pulsed Light IPL most commonly employed by medical practitioners and estheticians working under the guidance of a physician is a method of hair removal from the body It involves the use of a specially constructed xenon flash lamp and focusing optics The Intense Pulsed Light hair removal process has become very popular due to its cheaper and faster procedure compared to laser hair removal The comparison of effectiveness between Intense Pulsed Light and Laser Epilation is debated by scientists equipment manufacturers and practitioners but results are generally accepted to be roughly equivalent IPL is generally advertised as permanent hair reduction as opposed to permanent hair removal these phrases are misnomers when applied to laser or IPL hair removal It is also used for the
8. ame with yours 110V or 220V c It will hurt both you and the machine if you repair it when it is still working we strongly warn you that you must turn off the machine and pull out the electricity line and then start repairing it d Keep the filter and probe clean MAKE SURE there is no cooling gel inside the filter or probe e Stop using the machine when the headpiece is leaking water if it is already on pls close it immediately 5 27 Tel 91 95 03487924 E mail dev kanha86 ail com 2 KWARNING ON INTENSIVE LIGHT a The intensive light is possible to hurt your eyes or cause fire and burnt so we suggest you wear the glasses b It will hurt the customer if you use too high energy or make too many shots in one certain treatment area c Do not directly see the intensive light or laser light even if you wear the protective glasses and eye patch d Do not point the treatment head to the air Point it to the treatment area when using and hang it on the bracket when you don t use it Ul Safety of the electricity and equipment a Keep all the panels and cover board closed b There is high voltage inside the machine even when it is off So it is better not open the equipment if there is no need c Please make sure the electricity is off if you want to repair the machine d EANGEL301 is about20kg in net weight it might hurt people if you move it in not proper ways So pls make sure you move it slowly and carefully e
9. com I Functions of the E angel301 1 Hair removal both thick black hair and thin light hair 640nm 1200nm filter 2 Pigmentation removal 530nm 1200nm filter 3 Vascular therapy 480nm 1200nm filter 4 Skin rejuvenation 590nm 1200nm filter 5 Breast enhancing 690nm 1200nm filter I Taboos who are not suitable to use this machine a Pregnant b Isolation in the sun c Sensitive to light or medicine or are taking medicine that sensitive to light d Using vitamin within 6 months e Not representative naevi or malignant pathological changes in the treatment area f Pacemaker or quiver dispelling device user g Herpes or trauma h Pimple record i People who accept Hirudin etc treatment should stop using it before 2 weeks j Severe diabetes patient high blood pressure sufferer and epileptic 4 27 Tel 91 95 03487924 E mail dev kanha86 ail com Chapter 2 Safety notices of E angel 301 I IPL safety notices Tar eo eee ee en ag aT SS O EE me RR ES a Pa gt im 4 ar t E S FEFA i S3 zae eee Any people who are eligible in using and maintaining EANGEL301 can safely use this machine Any operators and his her assistants must know well the following safe notices and make sure both the operator and the customers are safe during the treatments Q The machine will start inspection automatically after it is on Adopt the close filter crys
10. e Operation manner continuous operation Q 7 27 Tel 91 95 03487924 E mail dev kanha86 ail com Chapter 3 Installation of E angel301 I Components of the device Main machine Power supply system Cooling system Joint part system Handle Probe Filters Assembly parts Key Cleaner Power line Water pipe Water funnel Professional protective glasses Professional protective eye patch 8 27 Tel 91 95 03487924 E mail _dev kanha8 amp 6 ail com Gr II Chow to install this machine E angel301 Radiation Tel 91 95 03487924 E mail _dev kanha8 amp 6 ail com OSMO CT a Open the package carefully place the machine on level ground Make sure the treatment room is clean and it is about 22 28 C and humidity not more than 20 c Atthe same time please carefully place the probe on the bracket show as below 10 27 Tel 91 95 03487924 E mail dev kanha86 ail com CT ects o o An R 3 o W z _ d Input distilled water or pure water i Screw off the caps of water inlet and spilt water Connect the water tube and water funnel well Insert the inlet to input water Stop inputting water when there s water spilt from the spilt water hole usually you might need 2 liters of pure water or distilled water After that you don t need to screw those 2 caps on because it needs air to cycle normally You jE f Please insert the key on the machine
11. how as follows If there is no output means that the direct current electrical source part is broken d Check up whether the water circulation is good to open the panel of one end of the handle as follow 6 Screw off these 6 screws and then disconnect the panel Tel 91 95 03487924 E mail dev kanha86 ail com OSMO Cr Disconnect the water plug with the connected water pipe then plug these two plugs into the joint on the back panel blow air inside the water plug with mouth see whether it is ventilated Or directly turn on the device see whether there is spilt water from these two plugs Remarks for the last test method we suggest that take a basin or other vessel load the spilt water 3 ty The xenon lamp is not on a The lamp is exhausted the lamp broken down b Poor contact anode and cathode line c Simmer board broken down 5 gt u Only LCD screen displays but can t enter into the treatment menu Touch LCD screen broken down 6 7 Water Leak from the probe a The xenon lamp broken down Poor connection inside Please disconnect the panel of the treatment head and tighten the screws show as follows 7 Replace the xenon lamp a Disconnect the panel of handle b Cut down the wire connection of lamp the insulating tape protecting electricity leakage 25 27 Tel 91 95 03487924 E mail dev kanha86 ail com CT c Weld down uw Cathode Two wire ends of the lamp Exactl
12. ics left d Use digital camera to keep an original picture Take photo from different angles e If necessary use external anesthetic one hour before the treatment f Before the treatment please make sure enough water and water circulation inside the device and wait till the probe gets cool then start to do the treatments us for help Otherwise it will hurt people and damage the machine During the treatment a Patients wear protective eye patch operator wear the professional glasses respirator and medical gloves b Spread approximate 3mm cooling gel in front the ears and below the chin Try to test it with 2 3 spots at the parameters that are set already After 3 5 minutes observe the skin to make sure that the customer is fit to these parameters If the probe is not cold or it even becomes hot please stop using this machine and turn to 14 27 Tel 91 95 03487924 E mail _dev kanha8 amp 6 ail com c s to protruding parts in the bone structure such as forehead mandible and cheekbone pls adjust different RF energy for different customers d During treatment vertically slide the bipolar probe on skin with level force and observe whether it s touched well or not Overlapped shoot offers good effects e Continuously press either of the 2 buttons on the headpiece or step the foot pedal make symmetrical output energy ANo do not press the button on handle one press by one press nor step the foot pedal step by step
13. ll be darker Pigment scab will shed 3 7 days later ecooling gel customer will feel less painful and the cooling gel can better lead light to skin eParameters Discharge interval 4 pulse number 5 7 8 8 0 5 0 LI LU 10 10 Discharge interval 4 pulse number 5 Tel 91 95 03487924 OSMO CT 8 0 8 2 5 0 LI LU 10 10 Discharge interval 4 pulse number 5 8 2 8 4 5 0 LI LU 10 10 milao with hair removal treatment Ps you don t need to cut hair before the treatment as that is for hair removal treatment only e1 3 or 3 6 treatments as one cycle eEvery 1 2 weeks for one treatment e The treatment theory is that stimulating the renewal of the mammary gland cells and enhancing the ligament tissue to plump the breast naturally Because the human metabolism cycle is 3 4 weeks the stimulated capillary vessel tissues will be shrinking and steady along with the metabolism eFeelings in the treatment Swollen feelings inside breast e Parameters Discharge interval 3 pulse number 3 4 2 4 6 4 0 Discharge interval 3 pulse number 3 Tel 91 95 03487924 OSMO CTi 4 4 4 8 4 0 U 5 5 Discharge interval 3 pulse number 3 4 6 5 0 4 0 9 Chapter5 Simple Maintenance of E angel 301 I precautions 1 No stress on the touch LCD prevent it from breaking up 2 Keep the filters clean Its not allowed to clean the filters with ethanol 3 The handle is fragile please do be caref
14. only e1 3 or 3 6 treatments as one cycle eEvery 3 4 weeks for one treatment ty Because the human metabolism cycle is 3 4 weeks the stimulated capillary vessel tissues will be shrinking and steady along with the metabolism eFeelings in the treatment Some pain feelings like needle pricking A little inflamed feelings on skin after the treatment ecooling gel customer will feel less painful and the cooling gel can better lead light to skin e Parameters Discharge interval 3 pulse number 4 7 6 7 8 5 0 LI LU 10 10 Discharge interval 3 pulse number 4 7 8 8 0 5 0 LI LU 10 10 Tel 91 95 03487924 OSMO CJ ECHe Discharge interval 3 pulse number 4 8 0 8 2 5 0 LI LU 10 10 Vascular Lesions Left leg before treatment 5 weeks post second treatment Pigmented Lesions Left hand before treatment 2 months post second treatment d pigment amp wrinkle removal treatment S90am 1200nmn inter cimilap with hair removal treatment Ps you don t need to cut hair before the treatment as that is for hair removal treatment only e1 3 or 3 6 treatments as one cycle eEvery 3 4 weeks for one treatment ty Because the human metabolism cycle is 3 4 weeks some decomposed pigment cells are phagocytosed by the lymphocyte and expel from the body along with the metabolism eFeelings in the treatment some pain feelings like needle pricking 3 30 minutes after the treatment pigment wi
15. tal of transferring light the IPL can only emit from the front face Independent electrical circuit it will automatically stop working if the energy is too high The emergency switch is convenient when you are in emergency e The key switch can protect it from stolen because they can t start the machine without certain key Qa oo o II Any intensive light without correct using will hurt people It can work out high voltage when working we suggest anybody who operates this machine should read this safety notices before using it For Operator it s possible to touch the intensive light So make sure you wear the 3 grade glasses For customer it is better if the operator is trained eligible and arrange a proper treatment room for the customer It is even better if the customer knows the treatment theory and cooperates with the operator during the treatment He she must make sure wear the professional protective eye patch which protects his her eyes from burning About the treatment room there must be clear mark which shows using intensive light NOW 1 MAIN WARNING Please make sure you will carefully read the following warning tips a Weneed to warn you that it has dangerous high voltage Anybody except technicians that authorized by our company can repair this machine Especially the inside of device e g electrical source cooling system optic organs and treatment head Etc b Make sure the voltage of this machine is s
16. ul when you pick up the headpiece 4 Change water each 3 6 months make sure water circulate normally before you start the treatment I Analysis On Simple Malfunction AW 1 es No power supplied 22 27 E mail dev kanha86 ail com Tel 91 95 03487924 OSMO CJ ECHe 2 don t worry You can DO AS following the sequence below to find out what the problem is Check up whether there is power supplied from electrical source Check up whether the power line is connected well Check up if the emergency switch is on Check up if the air switch is on Check up if the key switch is on Check up the fuse which could be pulled out at the bottom of hole for power plug Check up if the inside electricity line is connected well QA Q aeoHO AW 2 w The probe is not cold 1 Check up whether there s water in water tank and make sure water circulates normally 2 Check up the direct power supply switch whether there s 12V direct current output Reason of Non Refrigeration a Check up whether the Peltier is well or not 23 27 Tel 91 95 03487924 E mail dev kanha86 ail com OSMO C ECHe b After turning on the machine you should test the above Anode and Cathode with multimeter 12V DC output means the electrical source is well Please check up whether this two electrode is well or not which relate to the Peltier C 2 If above two electrodes don t have DC12V output please disconnect the panel s
17. y speaking red wire of lamp connects to red wire of handle white wire of lamp connects to white wire of handle All wire connections d Screw off these two screw caps show as follows side Screw off these two caps carefully e Insert the new lamp Tel 91 95 03487924 Caution i Wrap the wires of lamp by the insulating tape or tube before replacement And do as the above steps carefully or easy to break the lamp down Wire connection of lamp red wire of lamp connects to red wire inside handle white wire of lamp connects to white wire inside handle All wire connections cannot be mixed 26 27 E mail dev kanha86 Draw out the lamp from this ail com Gr f Take out the xenon lamp show as follows d Connect the new xenon lamp Weld the lamp wire with the wire inside the handle in accordance with the connection method of red wire on lamp to red wire inside the handle Chapter Contact us Beijing Eastbeauty Development Co Ltd Customers are always our friends Tel 0086 10 60216183 Fax 0086 10 61274251 O Homepage www eastbeauty org E mail linsa eastbeauty org 27 27 Tel 91 95 03487924 E mail dev kanha86 ail com
Download Pdf Manuals
Related Search
Related Contents
INSTALLATION MANUAL MANUEL D`INSTALLATION pdf AutoComp User Manual Origin Storage Thecus N4510U-R 8TB, 4-Bay RD-M771 PDFを開く - 株式会社オオトモ - OTOMO corporation TOP FEED FUEL RAIL KIT for 2002-14 WRX MTP40 User Manual Leseprobe - beck Manual Ver 1.1 C820-0019 Puentes, interruptores y conectores Copyright © All rights reserved.