Home
PTAG_26-02000_PT-LT_v2.1E
Contents
1. Options Pharma Test offers a broad range of accessories and options including Desiccators with the following dimensions Inner Diameter Useable Inner Height Volume Part No 380mm 283mm 18 51 26 02040 250mm 225mm 9 201 26 02030 200mm 175mm 4 45 26 02020 150mm 135mm 2 15 26 02010 Full range of certified validation tools available THE GERMAN GRUNDLICHKE T PTAG_26 02000_PT LT_V2 1E Page 3 of 4 onarnd TEST PT LT Leak Test Apparatus Technical Data Parameter Specification Vacuum Level Better than 600mmHg Vacuum Setting Vacuum can stabilize for a set value from Less than 400mmHg 10mmHg within 30 seconds Above 400mmHg 5mmHg within 30 seconds Display Large 16 x 2cm LCD Data Entry Function key Timer Can be set up to 99 minutes Desiccator Sizes 250mm 200mm or 150mm diameter optional Printer Parallel port for dot matrix printers Power Nominal 220 240V Dimensions Approx 400mm x 240mm x 220mm D x W x H Packaging Dimensions Approx 780mm x 580mm x 600mm D x W x H Net Weight Approx 14 5kg Gross Weight Approx 20 5kg Certification All components certified to USP EP requirements CE EMC Certification All CE EMC Certification provided Validation All IQ amp OQ documents included We deserve the right to make technical changes without prior notice THE GERMAN GRUNDLICHKE T PTAG_26 02000_PT LT_V2 1E Page 4 of 4
2. REPORT 08 04 2008 11 42 944888 DATE TIME USER ID PTAG_26 02000_PT LT_V2 1E SAMPLE ID NO OF SAMPLES BATCH NO SET VACUUM SET TIME TRIP VAUUM REMARKS SIGNATURE TEST 01 20711120 500mmHg 05 MINS 498mmHg ACCEPTED REJECTED THE GERMAN GRUNDLICHKE T Page 2 of 4 o onarmd TEST PT LT Leak Test Apparatus Advantages Some of the highlights the PT LT offers are Ensure the quality of your packaging process Easy operation by programmed sequence Fully automated microprocessor controlled equipment Stainless steel housing to fit well into a production area Q OQ documents included free of charge Features The main features of the PT LT are Test the integrity of strips blisters and bottles Large 16 x 2cm LCD shows vacuum and electronic countdown timer Enter all test parameters such as date time user ID and sample ID No of samples and batch number can be set via the keypad Set vacuum and trip vacuum can be set via the keypad Built in rugged oil free vacuum pump Automatic slow vacuum release from the desiccators Printer port for parallel dot matrix printers Automated print out of test report Standard Scope of Supply The PT LT comes ready to use with the following standard scope of supply PT LT instrument with built in vacuum pump Comprehensive documentation folder including User manual Q and OQ documentation Instrument logbook
3. ll bottles can also be tested A sheet of paper will absorb any leaking fluid Pharma Test Apparatebau AG P 49 6182 9532 600 Siemensstr 5 F 49 6182 9532 650 63512 Hainburg Germany info pharma test de www pharma test com PTAG_26 02000_PT LT_V2 1E Page 1 of 4 onarmd TEST PT LT Leak Test Apparatus Operation of the PT LT Leak Tester The operation of the PT LT leak tester could not be any easier Once on and the sample placed in position use the lt SET gt key and select your User ID Once this has been entered press the lt SET gt key once again and you can enter the Sample ID This is an alphanumeric entry which can be up to 8 characters long Using the lt SET gt key once again allows you to enter the Number of Samples Now enter the Batch Number again with up to 8 characters and then the Vac Set level which goes up to a maximum of 699mmHg Finally use the lt SET gt key to enter the Hold Time up to a maximum of 99 minutes Now press the lt ENTER gt key to accept the entered data Pressing the lt RUN gt key will now start the programmed sequence The vacuum pump then generates a vacuum in the desiccator holds it and then releases it using the time periods entered previously in the program Example Print Out A typical print out is illustrated below All results are presented in a convenient data block LEAK TEST APPARATUS SERIAL NO 0711120 MODEL NO PT LT TEST
4. onarma TeST PT LT Leak Test Apparatus PT LT Leak Test Apparatus The PT LT is used to test for the integrity of packed strips blisters and small sachets containing tablets granulates liquids and so on The instrument is used to test the quality of the packaging process and to check that the seals enclosing the product are perfectly intact The PT LT leak tester is designed to find the smallest holes and imperfections in blister packs and other semi rigid product packaging The leak test apparatus is widely applied in the pharmaceutical industry for checking strips blisters and bottles containing tablets capsules syrups and so on It also find application in the food industry where it can be effectively used to check the air tightness of sweet packets ready to eat pre packed foods confectionery packaging packs of noodles sauces to name but a few Samples are placed into the desiccator s housing and the lid is placed in position The pump starts to produce a vacuum inside the desiccators and the vacuum is held for a pre set time The first issue is that he tested package should keep its shape during this test otherwise the sealing is not correct Secondly as the package is immersed in a colored dye solution normally Methylene Blue the venting of the desiccators will allow any holes to be penetrated by the dye and the contents of the flexible packaging will also be stained with the same coloring material Similarly sma
Download Pdf Manuals
Related Search
Related Contents
Pioneer DEH-P580MP Speaker User Manual IFS-Anleitung _d-gb-f-it_ Vers 3_0 0900224 4 アピアガード - 株式会社LIXIL鈴木シャッター SmartPets 4 in 1 Training Collar User Manual Copyright © All rights reserved.
Failed to retrieve file