Home
User Manual - Savebase.com
Contents
1. Press key Functions Note Press corresponding key put the card close to 2 1 UU add card inductive zone to add card a new card replace the old card and the old 2 2 n modify replacement card card is cancelled at the same time 2 3 UU delete a single card UU is the user code 2 4 n delete all cards of group n 2 5 delete all cards This function is only for Master User 2 6 read card to cancel Press to cancel continuously 6 Access Control Master User verification keypad light turns on press the function key to set parameters before the keypad light turns off Two short beeps means failure and one long beep means success Press key Functions Note Enable the function of AHIHX i x 0 Disable 1 Enable forbidden access control Set the user groups which are 4 2 n n 1 5 group forbidden to open the door set User types which are 4H3HnHH n 1 password 2 card forbidden to open the door 7 Function of Empty Key o Hold the empty key for 3 seconds there is one long beep empty begins and you will hear the warming tone when finished o Loose the empty key before the long beep there is no operation then exit o After the long beep Master User password was recovered to 00123456 all the passwords and cards were emptied and recovered to default parameters
2. Page 1 User Manual Password RF Card Mechanical Key ELVES Page 2 Contents Part 1 Technical Parameters nnn nnn nnn nnn nnn nn nnn nnnnnnmnnn nnn 2 Part 2 Product Structure Map mm nennen 2 Part 3 Installing Instructions mmol nnn nnn nnn nnn enna 3 Part 4 Operating Instructions mn nn 5 Part 1 Technical Parameters Dimensions 160L 68W 36H mm Material Zinc Alloy Weight 2KG Operating Voltage DC6V 1 5V 4 AA Alkaline Batteries Static Current lt 20uA Dynamic Current lt 200mA Ways to open Password RF Card Mechanical Key User Management Capacity 56 Passwords 56 Cards Center Distance 60mm or 70mm Door Thickness 30mm 60mm Part 2 Product Structure Map LG 6 15 1443 42 1 1 lock cover 2 front lock plate 3 latch 4 fixing screws of latch 5 strike plate 6 plastic strike plate case 7 back lock plate 8 fixing screws of lock plate 9 battery 10 battery cover 11 fixing screws of battery cover Part 3 Installing Instructions Page 3 3 1 Drilling Hole 1 Mark on the door according to the drawing 2 Drill holes correspondingly with electro drill 3 Drill holes on the door frame with corresponding tools to install strike plate 3 2 Installing latch and strike plate 1 Fix
3. code as well e g 00123456 00 means user code 123456 is the password Enter normally open the green light turns on when opening the door hold key for 3 seconds the sound of normally open rings and enter normally open Exit normally open hold key for 3 seconds in normally open situation there is a long sound and exits normally open Remote control to open hold the open key on the remote control for 1 to 2 seconds there is a Page 6 long sound of the lock the door opened o Remote control to lock hold the lock key on the remote control for 1 to 2 seconds there is a short sound of the lock the door locked It can exit normally open through this operation o After enter setting or managing hold key twice to exit midway 4 Function Setting Input Master User password to verify door open keypad light turns on press corresponding function key to set parameters the black ones are factory default settings Press key Functions Note the boldface are default setting 9H0HxH password anti eavesdropping x O Disable 1 Enable 9H1HxH Key tones x 0 Disable 1 Enable O 2 x automatic normally open x 0 Disable 1 Enable it is in normally open after open the door O 3 x light flashing when normally open x 0 Disable 1 Enable 9H4HxH compositional verification x 0 Disable 1 Enable O 5 n password length n 4 8 The factory default is 6 O 6 n
4. ey 1 Take down the lock cover on front handle aa with plastic sucker Rf 2 Insert the right mechanical key turning 90 degrees 3 Push the handle door opened Page 5 Part 4 Operating Instructions 1 Summary User Management belongs to three level management model Master User first level Group Master User second level and User third level Password capacity one Master User password user code 00 five Group Master passwords user code 01 05 fifty User passwords user code 10 59 divided into five groups ten for every group fifty six passwords in total Card capacity one Master User card user code 00 five Group Master cards user code 01 05 fifty User cards user code 10 59 divided into five groups ten for every group fifty six cards in total Passwords and cards belong to the same User Group and have the same user code 2 User Specifications Master User the user code is 00 and has the full administration permissions The initial Master User password is 00123456 Group Master User the user code is On n means the group NO administrator of group n can add or delete Users in the group User the user code is n0 n9 n means the group NO user of group n have no administration authority Master User MUOO Password amp Card User GMUO1 GMUO2 GMUO3 GMUO4 GMUOS 3 Operation Hints When input the password to open the door you need to input the user
5. the lock on the door broadside with two screws 2 Fix the plastic bottom case and strike plate on the door frame with two screws 3 3 Installing square shaft of front lock plate 1 Put the square shaft into square hole on the front lock plate 2 Fix the square shaft with pin bolt in components bag and then open it 3 4 Installing front lock plate 1 Install front panel the two screw pillars should be aligned with the holes of the latch pull the connecting line of front panel to the back of the door in order to connect them Page 4 3 5 Installation of connecting line and back lock plate 1 Open the battery cover 2 Connect connecting lines of the front and the back lock plates 3 Fix the front and the back lock plates by 3 fixing screws 4 Positioning the lock plate properly tighten the 3 screws to fix lock plates 3 6 Equipping batteries 1 Put 4 AA batteries into the battery case u off and pay attention to the directions 2 Close the battery case and fix it with screws 3 Installation finished 3 7 Test after installation 1 The door can be opened normally when pushing the handle 2 After power on the motor reverse the handle will be idling when push it Input the initial password to check door opening 3 Make sure the door can be opened normally by the mechanical key 3 8 Usage of emergency mechanical k
6. times of continues wrong 0 disable the function The factory passwords to lock the keypad default is 3 times O 7 n minutes to lock the keypad after The factory default is 1 minute continuous wrong passwords 9 99 999 system empty and system reset The system will be recovered to factory default 5 User Management Add modify and delete password management Master User or Group Master User verification door open keypad light turns on press the function key before the keypad light turns off Two short beeps means failure and one long beep means success Press key Functions Note 1 1 UUPP add passwords UU is the user code password is PP 1 2HUUPP modify passwords UU is the user code 1 3 UU delete single user password UU is the user code 1 4 n delete all passwords of group n This function is only for Master User and the 1 5 delete all passwords Master User password cannot be deleted Modify the user password directly unnecessary to enter Master User model to modify self password Press key Functions Note T UU user code CP current password 5 UU CP NP User modify his own password NP new password Page 7 Add modify and delete RF card Master User or Group Master User verification door open keypad light turns on press the function key before the keypad light turns off Two short beeps means failure and one long beep means success
Download Pdf Manuals
Related Search
Related Contents
VIAFIX POWDER (M1203149 - 2006-06 Courseware «World Model 2 - Terrestrial Systems Ecology 日本語 User Guide - UBC ECE User`s Manual for American Telecom 6001S Service by SunRocket Quatro Sony SLV-D950B User's Manual Lexmark MS31X/41X/510/610 & MX310/410/51X/61X Product Study User Manual for the IP-710 DG35 Keypad User Manual Specifications Copyright © All rights reserved.
Failed to retrieve file