        INSTALLATION MANUAL WGA
         Contents
1.  shielded cable   Pin 1  RxD  of the display is connected to Pin 3  TxD  of the Fronius Display Card Box   Pin 2  GND  of the display is connected to Pin 5  GND  of the Fronius Display Card Box   Pin 3  TxD  of the display is connected to Pin 2  RxD  of the Fronius Display Card Box     The shield of the cable must be connected to 0 V  connector 1 pin 1  of the large display only   At the side of the Display Card Box the shield must be unconnected     The maximum possible cable length is 15 meters     Connection scheme    Display connector       1  2  Display Card Box 3 Connector 1  Display i   RS 232  2 Connector 2  4  w p  max  15 meters o 1      2 Connector 3      3  o  4    WGA 330 V1 04_e    2 5 Connecting the display to a Sputnik MaxComm Basic via RS 485    At connector 3 the display is connected to the RS 485 network with MaxComm Basic and  inverter s  via a shielded cable     Pin 1  Datat  of the display must be connected to Bus A of the RS 485 network   Pin 2  Data   of the display must be connected to Bus B of the RS 485 network     The shield of the cable must be connected to 0 V  connector 1 pin 1  of the display only   At the side of the network the shield must be unconnected     Hint  MaxComm Basic must have MaxDisplay 1 0 option     Connection scheme          MaxComm Basic    Display connector    Connector 3    10    WGA 330 V1 04_e    2 6 Connecting the display to Power One Aurora inverter s  via RS 485    At connector 3 the display is connected to the RS 485 n
2.  wish you good success with your new display     Please contact us if you have any questions or you don   t know exactly how to use the display     WGA 330 V1 04_e    Content    2 1  2 2  2 3  2 4  2 5  2 6    Page  Mounting the large display 4  General connection description 5  Connecting the display to an energy meter with impulse output 6  Connecting the display to a Sunny Boy Control via RS 232 7  Connecting the display to a Sunny Boy Control via RS 485 8  Connecting the display to a Fronius Display Card Box 9  Connecting the display to a MaxComm Basic 10    Connecting the display to Power One Aurora inverters via RS 485 11  Configure the display with the key 12  Technical data 14    WGA 330 V1 04_e    1 Mounting the large display    Warning  Improper use and mounting of the large display can cause serious injuries to  personnel and damage to the display     The large display is designed to mounting on a wall or similar  The connection of the display is  described at chapter 2 of this manual   The large display is only for indoor use     Important  The large display must be mounted with screws and dowels that fit to the underground  of the wall     Screws for upper housing profile        Upper housing     amp   profile    Hole for  wires    Hole for    Hole for mounting    mounting    Connectors    Key for  configuration    To open the housing of the large display unscrews the upper two screws in the upper housing  profile  Remove the upper housing profile and carefully r
3. INSTALLATION MANUAL WGA 330    Large display            son nenstrom  ba m Yi iy     i Mn    Aktuelle Leistung  W      Tagesenergie           Gesamtenergie       EXAMPLE    Date of issue 11 2010      specifications subject to change without notice      Weigel Me  ger  te GmbH    Postfach 720154 D 90241 N  rnberg Telefon  0911   42347 0    Erlenstra  e 14 D 90441 N  rnberg Telefax  0911   42347 39 IETT ETTEI     Vertrieb  0911   42347 94 RALL  Internet  http   www weigel messgeraete de    ml    vertrieb weigel messgeraete de    WGA 330 V1 04_e    Please read before use    This unit exists out of sensitive electronic parts and is therefore to protect from shock influence and  sudden climate variations    Be careful with the large display and don t push at the housing     We have tried to make this manual complete and correct  If you find any mistakes please inform  us     We don t take any responsibility  guarantee or warranty if you don   t use the large display in the  recommended way     All trademarks  into this document cover is taken  is property of the corresponding owner     Use only original parts  especially for the power supply unit  Separate the power supply unit from  the net if you have finished work with the large display  Power supply only for indoor use     Protect from high humidity  condensation  and high temperature  Only for indoor use     Introduction  Congratulation for your decision in purchased this large display   Please read this manual before use  We
4. e display   Necessary settings    Protocol  HvG    Baud rate  2400      further details see user manual Sunny Boy Control part  connections    headword  large display    and  headword  communication        Connection scheme    Display connector        1   Sunny Boy 2 _ Connector 1  Control      3  1   COMS 2 Connector 2     lo 3   RS 232  s    O max  15 meters    Connector 3    000  RON    WGA 330 V1 04_e    2 3 Connecting the display to a Sunny Boy Control via RS 485    At connector 2 the Sunny Boy Control is connected via a shielded data cable     Pin 1  Data   of the display is connected to Pin 3  Data   of COM 2 3 of the Sunny Boy Control   Pin 2  Data   of the display is connected to Pin 8  Data     of COM 2 3 of the Sunny Boy Control     The shield of the cable must be connected to 0 V  socket 1 pin 1  of the display only     Important note    The Sunny Boy Control must have a RS 485 interface  Piggy Back  at COM2 3   The Sunny Boy Control must be configured for using with the large display   Necessary settings     Protocol  HvG   Baud rate  2400      further details see user manual Sunny Boy Control part  connections    headword  large display    and    headword  communication        Connection scheme    Display connector    Connector 1    C tor 2  Sinny Bay onnector    Control 0    COM2 3    Connector 3   RS 485     1       WGA 330 V1 04_e    2 4 Connecting the display to a Fronius Display Card Box    At connector 2 the Fronius Display Card Box is connected by using a
5. emove the front cover by pulling out to the  upper side    Now the mounting holes and the electrical connectors are accessible     After mounting the large display on the wall the electrical connection is done like described below     WGA 330 V1 04_e    2 General connection description    Warning  Incorrect connection of the large display can cause serious injuries to  personnel and damage to the display   Especially never connect the display directly to the 230 VAC grid     After mounting the display must be connected to the power supply unit and the device who gives  the data to the display  data source      The large display provides different inputs     Impulse input for potential free close contacts of energy meters     RS 232 interface    RS 485 interface    Below the connections are described but please only use the description for the data source  you want to use     Connectors and pin definition    Connector Function Definition    1 Power supply Pin 1  0 V      Pin 2  not used  Pin 3    7 5 VDC  0 3 A       2 RS 232 interface Pin 1  RxD  Pin 2  GND  Pin 3  TxD  Pin 4 DTR  3 RS 485 interface Pin 1  Data   Pin 2  Data   Impulse input Pin 3  Impulse     potential free close contact  Pin 4  Impulse      Connecting the power supply unit       At connector 1 the DC output  free wires  of the delivered power supply unit is connected  If you  have to lengthen the cable please use cable with about 0 75 mm  cross section   Please take care of the polarity     After connecting 
6. etwork of the Power One Aurora  inverter s  via a shielded cable     Pin 1  Data   of the display must be connected to  T R  RS485 clamp 2  of the inverter s    Pin 2  Data   of the display must be connected to  T R  RS485 clamp 3  of the inverter s      The shield of the cable must be connected to 0 V  connector 1 pin 1  of the display only   At the side of the network the shield must be unconnected     Important hint  In difference to the manual of the Power One Aurora inverters  ALL Termin switches S1 must be in position  OFF      Please also note the manual of the Power One Aurora inverters     Connection scheme Display connector    Connector 1    WN       Aurora WR  1 o  1  B Shield N   5 Connector 2    5 Niwa   o  4           Connector 3    A E 2    Co Sf    o        I           4    11    WGA 330 V1 04_e    3 Configure the display with the key    After mounting and connecting  the display had to be configured   The display is preconfigured but it may be necessary to do some adjustments to fit to the local  situation     The following settings can be done     data source  from where the display get the data to show     If the data source is an energy meter with impulse output there are two additional settings     Starting value of the total energy  kWh     Impulse rate of the energy meter  Impulse per kWh     The configuration is done with the key on the connection circuit board shown at the picture on  page 4     The duration of pressing the key decide the reaction of 
7. play lines     13    WGA 330 V1 04_e    4 Technical data    number of values    display units 7 segment LED display with 20 mm digits  red hyper bright  resolution Depends on your order  Standard   Watt 4 digits  kWh 6 digits  kg 6digits    dimension ca  397 x 295 x 42 mm    business temp  5     40  C  storage and transport  temp    20      60  C    data source Impulse meters  potential free contact   SMA Control  Control Light and Control Plus  Sputnik MaxComm Basic  Fronius Display Card Box  CV485  Power One Aurora inverter  Solutronic inverter  others on request    power supply external power supply unit  Input  230 VAC  Output to large display 7 5 VDC    Never connect more than 12 VDC direct to the large display     CE  EN 61326 1    Changes in every kind possible  printed mistakes possible        14    
8. s DisplayCard Box RS 232 9  Solutronic inverter RS 232    If energy meter with impulse output is selected as data source the starting value of the total  energy  kWh  can be configured     At all other data sources the configuration is now finished     At energy meter with impulse output as data source now     Strt    appears in the upper  display line  Now the starting value of the total energy can be adjusted       Short key press  gt  the value of the changeable position increases by 1   starting in the right position     Important  The value of the number changes after releasing the key    Hint  The value jumps after 9 back to 0      Long key press  gt  the decimal point jumps to the next left position and the  next position can be adjusted   Exception  At the first right position no decimal point  appears    Important  Press key until decimal point jumps to the next left position    There must all 6 positions be adjusted otherwise the value will not be saved    After adjusting all positions of the starting value press the key long again until     PULS      appears in the upper display line  Now the adjustment of the impulses per kWh can be   done    The adjustment of the impulses per kWh is similar to the starting value of the total energy     There must all 5 positions be adjusted otherwise the value will not be saved     After another long key press the adjustments will be saved and the display starts the  normal measuring mode recognizable by a segment test in all dis
9. the display                             Duration Reaction Remark  Short  lt  1 second Value of the changeable The increment appears after  key press position is incremented by 1   releasing the key  Long  gt  1 5 second   The changeable position Press key until the decimal point  key press jumps to the next left jumps to the next left position  position or or  save settings display jumps to the next value       Configuration    a  While powering up the display press the configuration key    CFG    appears in the upper display line   b  After releasing the key    SrC    appears in the upper display line   c  Inthe second display line appears the number of the current configured data source   Now the needed data source can be configured    Assignment of number to data source see table below     Short key press  gt  the displayed number increases by 1  Important  The value of the number changes after releasing the key   Hint  The value jumps after 9 back to 0     Long key press   gt  the selected data source will be saved    Important  press key until the display makes a display test in all display lines or    Strt    appears in the upper display line     12    f     g     WGA 330 V1 04_e    The numbers in the second display line correspond to the following data sources     0  Energy meter with impulse output 5  RiCo RS 232   1  Sunny Boy Control RS 232 6  RiCo RS 485   2  Sunny Boy Control RS 485 7  CV 485   3  MaxComm Basic RS 485 8  Power One Aurora inverter RS 485  4  Froniu
10. the power supply unit and the data source  see below  to the large display the  power supply unit must plugged into a 230 VAC plug     Please note that the power supply unit is only for indoor use     WGA 330 V1 04_e    2 1 Connecting the display to an energy meter with impulse output    At connector 3 the impulse output  potential free close contact  of the energy meter is connected  by using a shielded cable     Pin 3  Impulse    of the display is connected to Impulse   of the energy meter   Pin 4  Impulse    of the display is connected to Impulse     of the energy meter     The shield of the cable must be connected to 0 V  connector 1 pin 1  of the large display only   On the side of the energy meter the shield must be unconnected     The maximum possible cable length is about 100 meters     Connection scheme    Display connector  Energy meter   Example        Connector 1    Connector 2       Connector 3       WGA 330 V1 04_e    2 2 Connecting the display to a Sunny Boy Control via RS 232    At connector 2 the Sunny Boy Control is connected via a shielded data cable     Pin 1  RxD  of the display is connected to Pin 3  TxD  of COM 2 3 of the Sunny Boy Control   Pin 2  GND  of the display is connected to Pin 5  GND  of COM 2 3 of the Sunny Boy Control     The shield of the cable must be connected to 0 V  socket 1 pin 1  of the display only     The maximum possible cable length is 15 meters     Important note   The Sunny Boy Control must be configured for using with the larg
    
Download Pdf Manuals
 
 
    
Related Search
    
Related Contents
Semaine de Pâques Cette année sur l`antenne de RCF la semaine  GPX SP300B docking speaker  Radio CD MP3 WMA Milano MP28 Monte Carlo  P2A Bedienungsanleitung  INV10120700 / INV20120700 / INV30120700 INV10121000  取扱説明書  informez, il en restera toujours quelque chose  Aprilaire Dehumidifier Troubleshooting Manual Models  the technical specification sheet  Elettropompa sommergibile ISTRUZIONI PER L`USO E    Copyright © All rights reserved. 