ALTERNATING PRESSURE PUMP AND MATTRESS USER MANUAL

image

Contents

1. 2 Proactive medical products 270 Washington Street Mount Vernon New York 10553 Tel 845 205 6004 Fax 845 205 6005 Www proactivemedical com 855 BE PROACTIVE 855 237 7622 ALTERNATING PRESSURE PUMP AND MATTRESS USER MANUAL INTENDED USE The Protekt Aire 4000 pump and mattress are intended to reduce the incidence of pressure ulcers while optimizing patient comfort It also provides the following 4 Individual home care setting and long term care Pain management as prescribed by a physician PRODUCT FUNCTIONS Pump The functions of the Protekt Aire 4000 pump are described below Please refer to the figures of the Protekt Aire 4000 pump 4 1 Power switch 2 Pressure adjust knob 3 Normal Pressure Indicator 4 Low Pressure Indicator 5 Alarm Reset 6 Static Control Power Switch 1 m The switch is at the right side of the pump E Turn ON OFF the power the pump will start stop operation Pressure adjust knob 2 E Turn the soft firm knob to set a comfortable pressure level Normal Pressure Indicator 3 m A visible indicator green tells the pressure has reached a preset or user defined level Low Pressure Indicator 4 m A visible indicator yellow or red warns the pressure is below a preset or user defined level Alarm Reset 5 E The audible visible alarm turns on when the pressure is low To mute the audible alarm press the reset button The visible alarm indicator will flash E Re p
2. WARRANTY 1 year for pump
3. ress the reset button to reactivate the alarm Static Control 6 Mm Press to set the air mattress either in static mode 2Proactiv medical products 270 Washington Street Mount Vernon New York 10553 Tel 845 205 6004 Fax 845 205 6005 Wwww proactivemedical com 855 BE PROACTIVE 855 237 7622 Mattress The Protekt Aire 4000 pump comes with cell type mattress of different materials Nylon PVC Nylon TPU or PU provided optionally with the pump Please refer to the specifications section for details OPERATING INSTRUCTIONS Place pump on horizontal surface or hang it by means of the hook Open mattress on the bed Secure it with end flaps or straps Air tubes must be at foot end of bed Connect air feed tubes to air outlet on the mattress and pump ensuring that the tubes are not kinked or twisted Allow space for bed rails to drop freely Turn on the pump power The indicator of the power switch will come on The pump starts to pump air into the mattress The Low Pressure indicator yellow or red will come on as inflation undergoes The Low Pressure indicator is activated to alert that pressure is low Audible alarm will be activated when the pressure is still low after about 60 minutes For first inflation we recommend that you press both the Alarm Reset and Static button to enter a quick and silent operation When the pressure reaches the preset level within approximately 30 minutes the Normal Pressure indicator
4. will come on and the Low Pressure indicator will turn off Turn the Pressure Adjust Knob to set a comfortable pressure level from soft to firm Press the Static button to set it in static mode and the Static indicator will come on The static mode will be started within approximately 6 minutes Press the Static button again to switch back to alternating mode Note In static mode the mattress provides a firm surface that makes it easier for the patient to transfer or reposition The static mode prevents the patient from bottoming out when in a sitting position ENVIRONMENT REQUIREMENTS ff fF F Operation Temperature 50 F 95 F 10 C 35 C Storage Temperature 5 F 122 F 15 C 50 C Operation Humidity 20 80 non condensing Storage Humidity 10 90 non condensing 2 Proactive medical products 270 Washington Street Mount Vernon New York 10553 Tel 845 205 6004 Fax 845 205 6005 Www proactivemedical com 855 BE PROACTIVE 855 237 7622 CLEANING GUIDELINES Can be cleaned by disinfectant solution Do not immerse the pump in water Do not heat or steam in autoclave ps The mattress and cover are aerated until they are fully dry TECHNICAL SPECIFICATIONS Item Protekt Aire 4000 Power supply 110V 60Hz LA Air output gt 7 liter min Pressure range 30mmHg 80mmHg Cycle time 10 min With normal low pressure light Size 28cm L x 20cm W x 10cm H Weight 2 2 kg Quick connectors

Download Pdf Manuals

image

Related Search

Related Contents

MSS 290 E - Utilul.ro  Step2 531700 Use and Care Manual      Jet Tools JML-1014 User's Manual  Methods for analyzing USB data traffic using a single USB host  LES RUPTURES DU CONTRAT DE TRAVAIL  150-AT002_-EN-P - Rockwell Automation  取扱説明書 取付・設置説明書  Fractal Design Tesla 450W  

Copyright © All rights reserved.
Failed to retrieve file