Product Manual M344 - Electric Time Company, Inc

image

Contents

1. No reset motor 12 04 2009 Electric Time Company inc Medfield MA 02052 USA Ph 508 359 4396 Fax 508 359 4482 www electrictime com electric time Lasan company inc CONNECTING SC 115 CLOCKS Stepper Corrective 115VAC COCK NOTE 24Vac Stepper corrective systems do not require te 120 an adapter box Connect L1 to movement L line L2 1 1 Ifthe adapter box is not already prewired to the 99BMI clock controller connect L1 L2 C and HR hour connects to movement S synch and C connects to N TO RELAY Scull strike from the 99BMI to the relay board 18ga neutral POAR recommended POWER IN 115VAC 60HZ 1A 2 Connect the power output wiring from the adapter box to the 99BMI 115 VAC POWER OUT 1X NORMAL 10X RESET 3 Connect L line S synch and N neutral movement 115VAC 60Hz 5A 115VAC 60HZ5A Wiring to L 1X and L 10X and N respectively on the relay board For multiple clocks Home Run wiring is required between each clock and one of the MI CLOCK outputs on 99B MI 00900 SC CLOCK 1 Owe TISVACIGOHZISA 4 Connect Hour Strike output if equipped Refer to 99BMI user manual M274 for hour strike configuration details 115 VAC BELL STRIKE 5 Connect 115Vac input power to the Power In location on the relay board 12 04 2009 Electric Time Company inc Medfield MA 02052 USA Ph 508 359 4396 Fax 508 359
2. to 99BMI user manual M274 for hour strike configuration 115VAC 60Hz 5A details 5 Connect 115Vac input power to the Power In 115 VAC BELL location on the relay board STRIKE 12 04 2009 Electric Time Company inc Medfield MA 02052 USA Ph 508 359 4396 Fax 508 359 4482 www electrictime com M344 electric time pg 12 of 13 company Inc NAT CLOCK OPERATION Dual Motor National Time 115VAC Using the relay adapter box with 99BMI controller 115Vac Dual Motor National Time clock movements will function per 99BMI user manual M274 Refer to M274 for all functions including setting time date and correcting the clock hands SPECIAL SETUP FUNCTIONS tech mode L1 L2 Drive Opt e Minute Impulse For MI style clocks L1 L2 Drive Opt e None Turns L1 and L2 function off Dual Motor NAT e SC Pulsed Stepper Corrective movements minutes corrected every hour hour corrected twice a day e Dual Motor L1 normal motor L2 reset motor L1 amp L2 operate on reset e Dual Motor NAT L1 normal motor L2 reset motor L2 only on reset e Dual Motor Stop L1 normal motor No reset motor 12 04 2009 Electric Time Company inc Medfield MA 02052 USA Ph 508 359 4396 Fax 508 359 4482 www electrictime com electric time ue company Inc SERVICE For assistance in troubleshooting problems or to request service contact the Electric Time Company Service Department at the address sho
3. 2 04 2009 Electric Time Company inc Medfield MA 02052 USA Ph 508 359 4396 Fax 508 359 4482 www electrictime com electric time re company inc CONNECTING Single Motor STOP Clocks Single Motor 115VAC 1 If the adapter box is not already prewired to the 99BMI clock controller connect L1 L2 C and HR hour strike from the 99BMI to the relay board 18ga recommended TO RELAY CIRCUIT BOARD POWER IN T 2 Connect the power output wiring from the adapter box mn to the 99BMI 115 VAC POWER OUT ne 3 Connect the normal motor to the adapter box i ne For multiple clocks Home Run wiring is required between each clock and the adapter box NORMAL MOTOR 4 Connect Hour Strike output if equipped Refer to 99BMI user manual M274 for hour strike configuration HOUR STRIKE details 115VAC 60Hz 5A 5 Connect 115Vac input power to the Power In location on the relay board 115 VAC BELL STRIKE 12 04 2009 Electric Time Company inc Medfield MA 02052 USA Ph 508 359 4396 Fax 508 359 4482 www electrictime com M344 electric time pg 10 of 1 company inc STOP CLOCK OPERATION Single Motor 115VAC Using the relay adapter box with 99BMI controller 115Vac Single Motor clock movements will function per 99BMI user manual M274 Refer to M274 for all functions including setting time date and correcting the clock hands Note The hands will not move
4. 4482 www electrictime com M344 electric time Pg 6 of 13 company inc SC 115 CLOCK OPERATION Stepper Corrective 115VAC Using the relay adapter box with 99BMI controller 115Vac SC clock movements will function normally through the 99BMI Some function are not possible with stepper corrective movements Refer to M274 to set the time and date SPECIAL SETUP FUNCTIONS tech mode L1 L2 Drive Opt e Minute Impulse For MI style clocks L1 L2 Drive Opt e None Turns L1 and L2 function off SC Pulsed e SC Pulsed Stepper Corrective movements minutes corrected every hour hour corrected twice a day e Dual Motor L1 normal motor L2 reset motor L1 amp L2 operate on reset e Dual Motor NAT L1 normal motor L2 reset motor L2 only on reset e Dual Motor Stop L1 normal motor No reset motor Advance Hands e Send 12 Hour Sends 12 hour pulse Hour hand advances to 6 00 Advance Hands e Send Hour Sends hour pulse Minute hand Send12Hour advances to 12 00 position 12 04 2009 Electric Time Company inc Medfield MA 02052 USA Ph 508 359 4396 Fax 508 359 4482 www electrictime com electric time Seas company inc CONNECTING DM Clocks Dual Motor 115VAC 1 If the adapter box is not already prewired to the 99BMI clock controller connect L1 L2 C and HR hour strike from the 99BMI to the relay board 18ga recommended TO RELAY CIRCUIT BOARD POW
5. ER IN T 2 Connect the power output wiring from the adapter box mn to the 99BMI 115 VAC POWER OUT oe ee 3 Connect the normal and reset motors to the adapter 115VAC 60HZ 5A 115VAC 60HzZ 5A For multiple clocks Home Run wiring is required between each clock and the adapter box NORMAL RESET MOTOR MOTOR 4 Connect Hour Strike output if equipped Refer to 99BMI user manual M274 for hour strike configuration 115VAC 60Hz 5A details 5 Connect 115Vac input power to the Power In 115 VAC BELL location on the relay board STRIKE 12 04 2009 Electric Time Company inc Medfield MA 02052 USA Ph 508 359 4396 Fax 508 359 4482 www electrictime com electric time nee company inc DM CLOCK OPERATION Dual Motor 115VAC Using the relay adapter box with 99BMI controller 115Vac Dual Motor clock movements will function per 99BMI user manual M274 Refer to M274 for all functions including setting time date and correcting the clock hands SPECIAL SETUP FUNCTIONS tech mode L1 L2 Drive Opt 7 e Minute Impulse For MI style clocks L1 L2 Drive Opt e None Turns L1 and L2 function off Dual Motor e SC Pulsed Stepper Corrective movements minutes corrected every hour hour corrected twice a day e Dual Motor L1 normal motor L2 reset motor L1 amp L2 operate on reset e Dual Motor NAT L1 normal motor L2 reset motor L2 only on reset e Dual Motor Stop L1 normal motor No reset motor 1
6. electric time di company inc 1X MOTOR NORMAL 12 04 2009 Electric Time Company inc Medfield MA 02052 USA Ph 508 359 4396 Fax 508 359 4482 www electrictime com M344 electric time Pg 2of 13 company inc INTRODUCTION The 99B MI Clock Controller with relay adapter box is a microprocessor based master clock that provides completely automatic control of minute impulse MI stepper corrective SC dual synchronous motor DM single synchronous motor STOP and National Time dual synchronous motor NAT clocks This manual provides installation instructions for connecting the various clock types and configuring the 99BMI Refer to M274 for complete 99BMI operation instructions TABLE OF CONTENTS CTRL 99BMI MI 115 2 2 3 CTRL 99BMI SC 2e nie net 5 CTRL 99BMI DM 2 2 2 ne aap eentee 7 CTRL 99BMI STOP nn site 9 CTRL S9BMINAT ee ee Speer eee ene ee ane nr nee opr re 11 SERVICE ees teeetercteweasaceseduaceiaedeterenecetedeeens 13 12 04 2009 Electric Time Company inc Medfield MA 02052 USA Ph 508 359 4396 Fax 508 359 4482 www electrictime com electric time mee company inc CONNECTING MI 115 CLOCKS Minute Impulse 115VAC 1 If the adapter box is not already prewired to the 99BMI clock controller connect L1 L2 C and HR hour strike from the 99BMI to the relay board 18ga recommended TO RELAY CIRCUIT BOARD POWER IN E 2 Connect the power output
7. when the hand position does not match the current time The Stop function waits up to 12 hours for the hands and current time to match before resuming normal operation SPECIAL SETUP FUNCTIONS tech mode L1 L2 Drive Opt 7 e Minute Impulse For MI style clocks L1 L2 Drive Opt e None Turns L1 and L2 function off Dual Motor Stop e SC Pulsed Stepper Corrective movements minutes corrected every hour hour corrected twice a day e Dual Motor L1 normal motor L2 reset motor L1 amp L2 operate on reset e Dual Motor NAT L1 normal motor L2 reset motor L2 only on reset e Dual Motor Stop L1 normal motor No reset motor 12 04 2009 Electric Time Company inc Medfield MA 02052 USA Ph 508 359 4396 Fax 508 359 4482 www electrictime com electric time Ror company inc CONNECTING NATIONAL TIME NAT Clocks Dual Motor National Time 115VAC 1 If the adapter box is not already prewired to the 99BMI clock controller connect L1 L2 C and HR hour strike from the 99BMI to the relay board 18ga recommended TO RELAY CIRCUIT BOARD POWER IN T 2 Connect the power output wiring from the adapter box mn to the 99BMI 115 VAC POWER OUT oe ee 3 Connect the normal and reset motors to the adapter 115VAC 60HZ 5A 115VAC 60HzZ 5A For multiple clocks Home Run wiring is required between each clock and the adapter box NORMAL RESET MOTOR MOTOR 4 Connect Hour Strike output if equipped Refer
8. wiring from the adapter box 115VAC 60Hz A to the 99BMI It 115 VAC POWER OUT oe 3 Connect L1 L2 and C movement wiring to L 1X and Owe L 10X and N on the relay board 115VAC 60HZ 5A 115VAC 60HzZ 5A For multiple clocks Home Run wiring is required between each clock and one of the MI CLOCK outputs on 99B MI T 4 Connect Hour Strike output if equipped Refer to SAC 99BMI user manual M274 for hour strike configuration details 115 VAC BELL 5 Connect 115Vac input power to the Power In STRIKE location on the relay board 12 04 2009 Electric Time Company inc Medfield MA 02052 USA Ph 508 359 4396 Fax 508 359 4482 www electrictime com M344 electric time Pg 4 of 13 company Inc MI 115 CLOCK OPERATION Minute Impulse 115VAC Using the relay adapter box with 99BMI controller 115Vac MI clock movements will function per 99BMI user manual M274 Refer to M274 for all functions including correcting time date and clock hand position SPECIAL SETUP FUNCTIONS tech mode L1 L2 Drive Opt 7 e Minute Impulse For MI style clocks L1 L2 Drive Opt e None Turns L1 and L2 function off Minute Impulse e SC Pulsed Stepper Corrective movements minutes corrected every hour hour corrected twice a day e Dual Motor L1 normal motor L2 reset motor L1 amp L2 operate on reset e Dual Motor NAT L1 normal motor L2 reset motor L2 only on reset e Dual Motor Stop L1 normal motor
9. wn below Electric Time Company inc Service Department 97 West Street Medfield MA 02052 USA Ph 508 359 4396 Fax 508 359 4482 Email service electrictime com 12 04 2009 Electric Time Company inc Medfield MA 02052 USA Ph 508 359 4396 Fax 508 359 4482 www electrictime com

Download Pdf Manuals

image

Related Search

Related Contents

Modules pour * Nakamura - Tome WT100    User Manual of the MASC Platform  Installation Operation Thermo Scientific ULT-80 & ULT-95  ABW Air Circuit Breaker ABW Interruptor Abierto ABW  English 3 Deutsch 6 Français 10 Italiano 14 Nederlands 18  HP-UX Internet Services Administrator`s Guide  Gi.Bi.Di. Continental Srl  