        Steampure 4 Manual.indd
         Contents
1.      4444444444444H HH 9  ACCESSORIES AND FILTER                                                 11  MAINTENANCE  amp  CLEANING                               nenn 12  WARRANTY e                        13  PARTS LIST AND DIAGRAM                             eem 14    Please read through all instructions in this manual prior to instal   lation  If you do not understand instructions  please seek assist   ance from an authorized SteamPure    Dealer or Distributor     IMPORTANT SAFETY INFORMATION    Operate indoors only    The area MUST be well ventilated    Always unplug the power cord before assembling  disassembling   repairing or adjusting the system   NEVER immerse the distiller in water or any other liquid    NEVER operate the distiller with a damaged cord or allow the cord  to become exposed to hot surfaces    Don t let children play with the distillation system    IF YOU ARE NOT SURE THAT YOUR OUTLET IS PROPERLY  GROUNDED OR THAT THE CIRCUIT PROTECTION IS COR   RECT  HAVE IT CHECKED BY A QUALIFIED ELECTRICIAN        FOR THE RECORD    The model and serial number are found on the back panel  You should  record both model and serial number for future reference     Model STEAMPURE PD    Date of Purchase          Serial Number       HOW DISTILLATION WORKS    Your system operates using the combined technology of evaporation conden   sation and carbon filtration  This combined technology consistently produces  high quality water  The principle of operation is quite simple  Raw wat
2.  from the service location        MAINTENANCE  amp  CLEANING  A  OVERALL MAINTENANCE REQUIREMENTS    The following guide should be used for maintenance of your  distiller  The timing will vary according to your local water con   ditions  It is your responsibility to maintain your equipment   Without proper maintenance  your SteamPure PD    may not  produce optimum results  The following times may need to   be adjusted for your particular area  so the first several times   please keep track of the average time and adjust the schedule  below     Weekly or every 12 gallons      Drain the boiling tank   Monthly or every 30 gallons   Clean the boiling tank   See  Section B of Maintenance    1  Change the post filter  2  Clean the exterior   3  Steam Sterilize     See page 6      Every 3 months       More frequent if feed water is hard     Cleaning the exterior   Use stainless steel cleaner and polish  stock  6606     Replacing the post filter   The post filter cartridge should be replaced at least every three    months  New filters can be purchased in packs of four through  your distributor or on our web site www steampure com   stock     19016   Replacement instructions are included with the filters     ELECTRICAL REQUIREMENTS    The unit must be plugged directly into a fully grounded wall outlet   You will need to use an isolated 10 amp circuit breaker for this unit     We offer this unit in two voltage configurations   120V  60 Hz models  5 8 amps   OR  240V  50 Hz models  2 9 
3. ERILIZING    We recommend that you thoroughly rinse and steam sterilize your STEAM   PURE PD before putting it into use  Distilled water from the first cycle should  be discarded     RINSING       1  Remove the boiling tank lid    2  Remove the wire restraining the float    3  Remove the cap from the extension tube on the drain valve    4  Pour tap water into the boiling tank until approximately   full  Open the  boiling tank residue drain valve   Close the residue drain valve after the water has drained     STEAM STERILIZATION      NOTE  Make sure the post filter is not installed at this point    Fill the boiling tank half full of hot tap water  Install the boiling tank lid   Plug the power cord into the power source    Turn the power switch ON    Turn the fan switch to STERILIZE      Allow the unit to steam sterilize for one hour  NOTE  Place a container  under the condensing coil outlet to catch any water or steam that drips  from the coil      After one hour  turn the power switch OFF      Allow the unit to cool for a minimum of 15 minutes  When cool  install  the post filter as instructed on page 7     START UP        13  Fill the unit with water  no higher than the maximum water level indicator  and place the glass jar under the post filter to catch the distilled water   Turn the power switch ON and fan switch to DISTILL  Allow the unit to  run through a complete cycle  DISCARD THE FIRST BATCH     With the power switch ON and the fan switch to DISTILL  the unit is now  
4. OAT BALL   BUSHING   O RING   USHING AND O RING KIT   18 19    ET SCREW   LOAT ACTUATING ARM   CTUATING ARM SET SCREW KIT   20 21   LOAT KIT   15 21    PACER   WITCH PLATE   EX NUT  1 4 20   MICROSWITCH   HEX NUT  4 40   SCREW  4 40 X 5 8   MICROSWITCH KIT   25 27    RESET RETAINER          RESET RETAINER BOARD  RESET   RESET KIT   24  24  28 30   BOILING TANK GASKET  BOILING TANK STUDDED  HEAT TAB   LOCK WASHER   HEX NUT  10 24   U CLAMP   U CLAMP KIT   5   35 36   HEATING ELEMENT GASKET  HEATING ELEMENT  650 WATTS  HEATING ELEMENT KIT   5   35 38   DEFLECTOR PLATE   PUSH NUT   FAN BLADE   FAN BLADE KIT   43 44    FAN MOTOR   FAN MOTOR KIT   48   40 42   WIRE CABLE HOLDER  ON OFF SWITCH   HEX NUT  8 32   TERMINAL BLOCK   SCREW  8 32 X 1 2   LOCK NUT  8 32   APPLIANCE FEET   SS FRONT PLATE   SS BASE   SCREW  10 24 X 1 2   LOCK WASHER   10   IEC CORD CONNECTOR   SS BACK PLATE   DRAIN VALVE  INCLUDES  57 58   COMP  FERRULE   COMP  NUT   DRAIN EXT TUBE          TABLE OF CONTENTS    IMPORTANT SAFETY INFORMATION                                  3  FOR THE RECORD nassen 4  HOW DISTILLATION WORKS                             nennen nennen 4  UNPACKING YOUR STEAMPURE PD  ooo eee 4  ELECTRICAL REQUIREMENTS                                  eese 5  SPECIAL NOTICE cocinada iii 5  GETTING AQUAINTED WITH YOUR STEAMPURE PDT     6  COMPONENT IDENTIFICATION                    244   444444 7  FIRST TIME START UP  RINSING  amp  STERILIZING                8  POST FILTER INSTALLATION              
5. STEAM PURE    PD     Personal Distiller  OWNERS MANUAL                                                                                           STEAMPURE PD    PARTS LISTING    224 0003 224 0003    409  636  638    9530  9510  9545  657  513  9018  9519  9080  6021  604  9024  9082  609  644  8070  516  9045  7200  9041  9001  646  424A  510  601  663  6010    2590A 02 2590A 02    2102  9032  9061    400A 02 400A 02    661  6005  7022   632  2103  9092  7010   639  7092   653  7230   642  9043   418  9095  9003  8011    9056  9046  7275    9508  87  84   518    240V  8009  6022  519  6049  9009  9085  402B    409  636  638    9530  9510  9545  657  513  9018  9519  9080  6021  604  9024  9082  609  644  8070  516  9045  7200  9041  9001  646  424A  510  601  663  6010    2102  9032  9061    661  6005  70102  632V  2103  9092  7010  639  70103  653V  7230  642  9043  418  9095  9003  8011    9056  9046  7275    9508  87  84   518    De otion  LID KNOB WITH STUD 120V__240V__Description  O RING   611 611   LID DISC   GASKET 19016     19016    FLAT WASHER  1 4  9233 9233    DRAIN EXT TUBE KIT  457 59   CONNECTION FITTING   POST FILTER  4 PACK   BOTTLE LID WITH HANDLE  GLASS BOTTLE    SPRING TS gO  IEC POWER CORD    CROSSBAR WITH NUT 7276 7276  LOCKNUT  1 4 20   LID ASSY    1 8    ACORN NUT  4 PACK    SHEET METAL SCREWS  12 PACK   S S  TOP COVER  CALL FOR COLORS   COMPRESSION FERRULE  COMPRESSION NUT   CONDENSING COIL   CONDENSING COIL KIT   12 14   FLOAT ROD   HEX NUT  6 32   FL
6. amps    SPECIAL NOTICE    A short power supply is provided to reduce the risks resulting  from becoming entangled in or tripping over a longer cord     Extension cords may be used if care is exercised in their use     If an extension cord is used   a  the marked electrical rating of  the extension cord should be at least as great as the electri   cal rating of the product   b  as the product is of the grounded  type  the extension cord should be a grounding type 3 wire  cord  and  c  the longer cord should be arranged so that it   will not drape over the countertop or tabletop where it can be  pulled on by children or tripped over unintentionally     The physiological effects of the operation of this appliance   beneficial or otherwise have not been investigated by Under   writers Laboratories        GETTING ACQUAINTED WITH  YOUR STEAMPURE PD       Condenser  with Volatile  Maximum Water Level Gas Vents    Indicator    Boiling  Chamber Heating  Element    Condenser  Outlet          do    SP    O  sg  Ss     gt   N                      O      f          Residue  Drain Valve    ACCESSORIES AND FILTER    ADDITIONAL GLASS JUGS   Many people like to have an additional glass jug  so that they  can have one jug in the refrigerator  and another jug at the water  distiller     Additional jugs can be purchased from your dealer  or from  www steampure com     FILTERS   The SteamPure PD    will boil water  collect the steam and then  cool it so that distilled water condensates into the g
7. er is  poured into the machine where it is heated and boiled  As the water boils  it  kills bacteria and other biological contaminants  The steam then rises  leav   ing behind virtually all the contaminants in the raw water  The steam enters  the condenser where cool air reduces the temperature of the steam  convert   ing it to distilled water as a final step  this water passes through an activated  carbon post filter to improve the taste of the water  The water is collected    and stored in a glass container     UNPACKING YOUR STEAM PURE PD       Your STEAMPURE PD  is shipped to you in a durable carton  Carefully  remove the contents from the carton     The STEAMPURE PD    carton contains   STEAMPURE PD distillation system  Glass container and lid  Parts kit  2560  Owners manual and warranty card  Power cord    Note  Save the carton and packaging material for future use in the unlikely  event your machine should require maintenance or repair     B  CLEANING THE BOILING TANK    We recommend that the boiling tank be cleaned at least once per month   Use Lumen    cleaner  stock  6603  and follow the directions below  Failure  to clean the interior can result in     1  Contaminant build up  scale  causing premature failure of the heating  element    2  Reduced purity of the distilled water due to    splash over    of contaminants  from the boiling tank     CAUTION  Under no circumstances should the cleaning solution be  heated and ran through a steam sterilization or distillatio
8. g onto the con   denser outlet  Gently pull on the elbow to make sure it is locked in place                 Shoulder       Figure 1    
9. lass jar   There are some chemicals that have a lower boiling point than  water  that can carry over with the steam  The carbon filter will  remove these contaminants     Filter Replacements can be purchased from your dealer  or from  www steampure com     CLEANING COMPOUND   When the SteamPure PD    boils water  the calcium and mag   nesium in the water  along with some other contaminants can  form scale  The scale will reduce the efficiency of the unit over  time  Once the scale starts to accumulate  it should be cleaned  off  We supply a powder that is allowed to sit overnight in a  cold boiling tank  This will soften the scale so that it is easier to  remove     Lumen  can be purchased from your dealer  or from www   steampure com        POST FILTER INSTALLATION  CONT   D      4  Position the post filter loosely into the mouth of the glass  jar as shown in Figure 2  The unit is now ready for normal  operation     5  To remove the filter  the adjustable collet  A  must be loos   ened and the grey collet  B  must be depressed before pull   ing the fitting off of the condenser outlet     If installation of the filter onto the condenser outlet is difficult   you may apply a thin film of vegetable oil to the OUTSIDE  surface of the condenser outlet to aid installation                          Figure 2    10    COMPONENT IDENTIFICATION    Boiling chamber   The manually filled stainless steel boiling chamber  holds a maximum of 1 4 gallons  5 3 liters  of water     Condenser   A
10. n cycle     Use the following procedures for cleaning the boiling tank in the  STEAM PURE PD     Turn the power switch OFF  Turn the fan switch to STERILIZE  Let the  unit cool down for 15 minutes before continuing    Remove the boiling tank lid  Open the drain valve and allow the boiling  tank to drain  Close the drain valve    Pour water into the boiling tank so the water level is just above the scale  line    Add the Lumen TM Cleaner following the directions on the package   Mix well and let stand overnight    Next morning  open the drain valve and drain and rinse the boiling tank  thoroughly  Close the drain valve    Steam sterilize the unit by following the instructions for Steam Steriliza   tion and Start Up on page 6     WARRANTY    Your SteamPure PD    water distiller is covered by a comprehensive war   ranty  Please refer to the warranty card for full details  If your warranty card  is missing  or if this is a replacement manual please contact your dealer or  distributor for full details  In order for the warranty to be registered  you must  return the warranty card within 10 days of purchase  Please be sure all the  information on the warranty card is filled in completely for valid registration     If your SteamPure PD    requires repair under warranty  contact your dealer  or distributor for instructions  Provided you have met your conditions under  the warranty  the system will be repaired free and returned to you  You are   responsible for the freight both to and
11. ready for normal operation  We recommend steam sterilization cycle  steps  5 12  every 3 months or if the unit has not been used for one week     POST FILTER INSTALLATION    NOTE  The post filter must be removed during steam sterilization     This distillation system is equipped with an activated carbon post filtering  system designed to polish the taste after distillation  The filter helps ensure  the distilled water produced is as fresh and great tasting as possible  This  combination of distillation and filtration produces  the Full Spectrum Solution  To Water Pollution   TM     To maintain the freshness of the water  the post filter should be changed on a  periodic basis  See page 9 for the schedule     NOTE  Steam sterilize the unit prior to installing the post filter     1  Remove the plastic plug covering the filter outlet  Remove the post filter  lid     Rinse the carbon by slowly pouring DISTILLED  water into the lid area  and allowing the black carbon fines to rinse away  Continue until the  water coming out the bottom of the filter is clear  Install the post filter lid  and snap it closed      Use distilled water only to rinse the post filter    While making sure the adjustable collet is loose  install the elbow and the  new filter onto the condenser outlet  This is done by pushing the elbow  straight into the condenser outlet tube until it bottoms on the shoulder   approximately 1    See figure 1     Finger tighten the adjustable collet securely to seal the fittin
12. s the steam rises from the surface of the water in the  boiling tank  it enters the condenser where it is cooled by forced air  from the fan which converts it to distilled water  The condenser also  has volatile gas vents to allow gasses to escape    Residue drain valve     The drain valve  located on the rear panel of  the unit  provides a means of draining the residue from the boiling  chamber that remains after distillation     Fan     The fan provides a constant flow of room temperature air  across the condenser during the distillation cycle to effectively con   dense the steam from the boiling water     Fan Switch  not shown      The fan switch must be in the PURIFY  position during the distillation cycle to provide efficient air flow across  the condenser  It is only in the STERILIZE position during steam  sterilization     Float     The float is used to monitor the water level in the boiling  chamber  When the level reaches approximately 1    above the heating  element  the float trips a switch to shut the unit down     Heating Element     The 650 watt heating element provides the heat  necessary to boil the water in the boiling chamber     Maximum Water Level Indicator     A small diameter rod which  extends downward 1 1 2    from the top of the boiling chamber  When  operation the unit  fill the water no higher than the bottom of the indi   cator     Power Switch  not shown      Allows the user to turn power ON and  OFF       FIRST TIME START UP  RINSING AND STEAM ST
    
Download Pdf Manuals
 
 
    
Related Search
    
Related Contents
CS/CJ Series Programmable Controllers  Manual de Instrucciones Manual de instruções  Conceptronic Desktop 600W  Business Telephone User Guide  Condicionadores de ar  FD-2200マニュアル1  Untitled - Flugschule Hochries  PCD CDM8635 User's Manual  Sencor SVC 730RD ALTO vacuum cleaner  置時計取扱説明書    Copyright © All rights reserved. 