Home

Sira Certification Service

image

Contents

1. reproduced in its entirety and without change Sira Certification Service Form 9400 I ssue3 Rake Lane Eccleston Chester CH4 9JN England Tel 44 0 1244 670900 Page 3 of 3 Fax 444 0 1244 681330 Email info siracertification com Web www siracertification com Certificate Annexe d Certificate Number Sira 13ATEX2390X S f ra Equipment PGM 25xx and PGM 25xxD multi sensor gas detector CERTIFICATION Applicant Rae Systems I nc Issue O Title PGM 25xx Hardware Equivalent Circuit PGM 25xx Function Block Diagram PGM 25xx 2500D General Description 900 MHz wireless modem RAE Main Board layout M02 1010 SCH 1to7 8 tifFeb 4 Main PCB Schematic o Z M02 1011 SCH 1to4 8 11Feb14 Analog Board Schematic M02 4001 CTL 1to13 B 11Feb14 User Manual Controlled prt Issue 1 Date Sira Stamp M02 1011 SCH 01 April 15 Schematic PGM 2500x Analogue Board M02 1110 BOM 01 April 15 BOM PGM 2560x Analogue Board M02 1100 000 1to13 B 01 April 15 PCB Layout PGM 2560x Analogue Board M02 1110 SCH 01 April 15 Schematic PGM 2560x Analogue Board This certificate and its schedules may only be reproduced in its entirety and without change Sira Certification Service Rake Lane Eccleston Chester CH4 9JN England Tel 44 0 1244 670900 Page 1 of 1 Fax 44 0 1244 681330 Email info siracertification com Web www siracertification com
2. Form 9400 I ssue3
3. 0 If the sign X is placed after the certificate number it indicates that the equipment is subject to special conditions for safe use specified in the schedule to this certificate 11 This EC type examination certificate relates only to the design and construction of the specified equipment If applicable further requirements of this Directive apply to the manufacture and supply of this equipment 12 The marking of the equipment shall include the following 11 16 Ex ia IIC T4 Ga Ta 20 C Tamb 50 C Project Number 70009414 A C Smith Certification Manager This certificate and its schedules may only be reproduced in its entirety and without change Sira Certification Service Rake Lane Eccleston Chester CH4 9JN England Page 1 of 3 Form 9400 Issue 3 Tel 44 0 1244 670900 Fax 44 0 1244 681330 Email info siracertification com Web www siracertification com 13 14 14 1 14 2 15 15 1 15 2 15 3 sira CERTIFICATION SCHEDULE EC TYPE EXAMI NATI ON CERTIFICATE Sira 13ATEX2390X Issue 1 DESCRI PTI ON OF EQUI PMENT The Model PGM 25xxx is a multi sensor gas detector designed to provide continuous exposure monitoring of gases such as CO H2S O2 LEL gases for workers in hazardous environments The first and second x can be any number from 0 to 9 reflecting the combination of sensors used The third x is either blank for pump model or a D for diffusion model The gas detec
4. ate Annexe Associated Sira Reports and Certificate History Issue Date Report no Comment 0 12 February 2014 R32498A 00 The release of the prime certificate 1 12 May 2015 R70009414A The introduction of Variation 1 SPECI AL CONDITIONS FOR SAFE USE denoted by X after the certificate number The PGM 2500 PGM 2500D PGM 2560 PGM 2560D shall only be fitted with RAE Systems Battery Pack type G02 3004 000 The PGM 25xxx shall only be charged outside the hazardous area The PGM 25xxx shall only be charged with a RAE Barrier p n M02 3011 000 that limits Uo to 20 V This certificate and its schedules may only be reproduced in its entirety and without change Sira Certification Service Form 9400 I ssue3 Rake Lane Eccleston Chester CH4 9JN England Tel 44 0 1244 670900 Page 2 of 3 Fax 444 0 1244 681330 Email info siracertification com Web www siracertification com 16 17 17 1 17 2 sira CERTIFICATION SCHEDULE EC TYPE EXAMI NATI ON CERTIFICATE Sira 13ATEX2390X Issue 1 No precautions against electrostatic discharge are necessary for portable equipment that has an enclosure made of plastic metal or a combination of the two except where a significant static generating mechanism has been identified Activities such as placing the item in a pocket or on a belt operating a keypad or cleaning with a damp cloth do not present a significant electrostatic risk However where a st
5. atic generating mechanism is identified such as repeated brushing against clothing then suitable precautions shall be taken e g the use of anti static footwear This equipment has not been assessed in accordance with the requirements in respect of safety related devices that are defined in EHSR 1 5 of directive 94 9 EC in consequence it shall not be used for an application where it is intended to contribute to or is required for the safe functioning of equipment or protective systems with respect to the risk of explosions ESSENTI AL HEALTH AND SAFETY REQUI REMENTS OF ANNEX II EHSRs The relevant EHSRs that are not addressed by the standards listed in this certificate have been identified and individually assessed in the reports listed in Section 14 2 CONDITI ONS OF CERTI FI CATI ON The use of this certificate is subject to the Regulations Applicable to Holders of Sira Certificates Holders of EC type examination certificates are required to comply with the production control requirements defined in Article 8 of directive 94 9 EC The products covered by this certificate incorporate previously certified devices it is therefore the responsibility of the manufacturer to continually monitor the status of the certification associated with these devices and the manufacturer shall inform Sira of any modifications of the devices that may impinge upon the explosion safety design of their products This certificate and its schedules may only be
6. sira CERTIFICATION 1 EC TYPE EXAMI NATI ON CERTI FI CATE 2 Equipment intended for use in Potentially Explosive Atmospheres Directive 94 9 EC 3 Certificate Number Sira 13ATEX2390X Issue 1 4 Equipment PGM 2500 PGM 2560 PGM 2500D and PGM 2560D multi sensor gas detector 5 Applicant Rae Systems I nc 6 Address 3775 North First Street San Jose California 95134 United States of America 7 This equipment and any acceptable variation thereto is specified in the schedule to this certificate and the documents therein referred to 8 Sira Certification Service notified body number 0518 in accordance with Article 9 of Directive 94 9 EC of 23 March 1994 certifies that this equipment has been found to comply with the Essential Health and Safety Requirements relating to the design and construction of equipment intended for use in potentially explosive atmospheres given in Annex II to the Directive The examination and test results are recorded in the confidential reports listed in Section 14 2 9 Compliance with the Essential Health and Safety Requirements with the exception of those listed in the schedule to this certificate has been assured by compliance with the following documents EN 60079 0 2012 EN 60079 11 2012 EN 60079 26 2007 The above list of documents may detail standards that do not appear on the UKAS Scope of Accreditation but have been added through Sira s flexible scope of accreditation which is available on request 1
7. tor gives real time gas measurements and provides an audible and visual alarm when gas levels exceed the preset limits The visual alarm comprises a Red LED bar visual from the top Additionally an imbalanced motor produces a vibration alert when in alarm mode Two push buttons facilitates the access to measured levels or alarms and the mode button allows changing preset limits A wireless modem is provided as an option The physical dimensions are 152 mm x 83 mm x 43 5 mm PGM 25xx and 141 mm x 83 mm x 38 5 mm PGM 25xxD The weight is about 414 g PGM 25xx and 365 g PGM 25xxD There are no external connectors except for the charging and PC communication contacts The unit is powered by a 3 7 V Li lon Battery Pack The Battery Pack is replaced by removing a cover that is retained by fasteners Variation 1 This variation introduced the following changes i The nomenclature for model PGM 25xx has been replaced with PGM 2500 or PGM 2560 and PGM 25xxD with PGM 2500D or PGM 2560D the conditions were amended to reflect this change ii The inclusion of an alternative analogue board QRAE3 PGM 2560 Rev B 1444 M02 1100 000 was endorsed This board is used in models PGM 2560 and PGM 2560D ii The power supply to two potentiometers U2 U3 has been amended iv Schematic designators for socket 2 sensor channel 2 and socket 3 sensor channel 3 were corrected on schematic M02 1011 SCH DESCRI PTI VE DOCUMENTS Drawings Refer to Certific

Download Pdf Manuals

image

Related Search

Related Contents

Allied Telesis 1000LX SFP 40 Km (1550nm)  PDS-70mr D.E.P rev02(改).ai  電子計算機<X-ViZ - Flower Robotics  取扱説明書  CAIRE April 2013 Med Tips  コンパクトボディに パワー&スタミナを凝縮!  PRO3 User manual  iiyama ProLite C1911S-B1  ARPrv Control v1.0 User Manual doc-v1.0  "1' SERVICE MANUAL  

Copyright © All rights reserved.
Failed to retrieve file