Home

Sopro Intraoral Camera Manual PDF

image

Contents

1. Connect the USB cable between the connection box and one of the computer USB ports 7 3 SOPRO IMAGING SOFTWARE INSTALLATION Insert the SOPRO Imaging CD ROM into the driver It automatically executes Sopro 617 gt User manual 13 ENGLISH WARNING If the CD ROM does not automatically run or if the operating system is lower than Windows XP SP1 follow the below instructions Go to the Start menu Execute Type D setup exe replace D by the letter of the CD ROM driver And then click on OK The file instantly runs then follow the steps from the below point NOTE Clicking on the key Browse this CD ROM allows access to a Windows browse window from which it is possible to consult the whole content of the CD ROM At the CD ROM root there are the files allowing the automatic launch and or the manual setup in the directory Document and its subdirectories there are all the documents about the Imaging SOPRO software and the Sopix system these documents are in PDF format Make sure to correctly install Acrobat Reader in case of reading difficulties the Drivers directories contain the drivers necessary to use the hardware accepted by SOPRO Imaging Sopix system SOPRO cameras in USB 1 and USB 2 Hasp protection key the directory SOPRO Imaging contains the SOPRO Imaging installation program the directory Tools contains the Microsoft Direct X 9 0 c and ADOBE Acrobat Reader i
2. 1 PAL or NTSC Video output 1 PAL or NTSC S Video output Controller dimensions L 145 W 130 35 mm Controller weight 245 Sopro 617 ENGLISH DOCK MU USB2 Memory 1 and 4 images Power supply 24 V 50 Hz 60 Hz Consumption 10 VA 1 PAL or NTSC video output 1 PAL or NTSC S video output 1 digital USB output 2 0 Controller dimensions L 100 W 72 36 mm e Dock weight 190 g DOCK MU VIDEO Memory 1 and 4 images Power supply 24 V 50 Hz 60 Hz Consumption 10 VA 1 PAL or NTSC video output 1 PAL or NTSC S video output Controller dimensions 1 100 72 36 mm e Dock weight 190 g DOCK USB2 e Cable length 3 5 m 1 USB output 2 0 Dock dimension L 100 W 46 20 mm Dock weight 165 g Operating temperature 10 to 40 Storage temperature 20 C to 45 Relative humidity 10 to 90 Atmospheric pressure 900 hPa to 1 060 hPa Continuous service Not protected against water chutes Not adapted to the use in presence of an anaesthetic mixture flammable with air oxygen or dinitrogen monoxide Complies with the European directive 93 42 EEC Complies with EC60601 1 standard 24 Sopro 617 User manual Non contractual document Ref 011218 B Copyright 2007 SOPRO All rights reserved No information or part of this document may be re
3. SOPRO 7 USER MANUAL SoproTouch R O ACTEON Imaging S H ENGL Contents FOREWORD 2 DENTAL CAMERA INTRODUCTION 3 SAFETY INSTRUCTIONS URS CER OPE RC RE 5 REGULATORY REQUIREMENTS 6 INSTALLATION scm mehrere 11 CONNECTING TO A VIDEO 12 CONNECTING TO A COMPUTER n n n n 13 DESCRIPTION OF THE CONNECTION BOXES 16 MAINTENANCE RES eR ern 18 AFTER SALES SERVICE entree ey Rm 20 TECHNICAL FEATURES 23 Sopro 617 gt User manual eceoooocoocooco ENGLISH 0 FOREWORD Thanks for trusting us by purchasing this device In order to optimize the use of the device while taking all the necessary precautions it is recommended to carefully read and follow the user manual Always carefully consider the messages CAUTION WARNING and NOTE when using the system CAUTION the term CAUTION describes potential incidents likely to jeopardize safety WARNING the term WARNING refers to the incidents likely to disturb the smooth running of the imaging system NOTE the term NOTE highlights particular points in order to facilitate the system maintenance or to clarify important information 2 Sopro 617 User manual ENGLISH DENTAL CAMERA INTRO
4. terms are read click on Next By default the Imaging SOPRO software will automatically install in the directory C Program Files SOPRO Imaging To start installing the software click on Next Once the installation is completed a dialog box displays Click on Finish 7 4 SOPRO IMAGING SOFTWARE CONFIGURATION Refer to the installation and configuration manual of the USB connections for Sopro camera that is on the Sopro Imaging CD ROM in the document directory Sopro 617 gt User manual 15 ENGLISH DESCRIPTION OF THE CONNECTION BOXES 8 1 DOCK M_USB2 OR DOCK M_VIDEO POWER SUPPLY The dental camera power supply is connected to the power outlet The other end of the cord is connected to the dock where the symbol 6V is located PHIHONG PSA 10R 060 or FRIWO Model MPP15 FW 7555M 06 model The power supply automatically adapts to the electric networks 110 V 230 V 50 Hz 60 Hz 0 5 A The camera voltage is powered by 6V of a continuous low voltage type 1 67 8 2 DOCK MU_USB2 OR MU_VIDEO POWER SUPPLY The electrical connection of this connection box should be performed by the installer The dental camera electrical supply is realized through the connection box that should be connected 24 V 50 Hz 60 Hz 10 VA 8 3 DOCK USB2 POWER SUPPLY The dental camera electrical supply is directly performed through the computer USB port The voltage powering the camera is of continuous 5 V low voltag
5. the green indicator light should be on e Only use the power supply provided with the connection box 6 2 DOCK MU USB2 OR DOCK MU VIDEO CONNECTION Please refer to the integration manual of DOCK MU USB2 DOCK MU VIDEO for its connections Connect the connecting cable to the handpiece Connect the video cable preferably Y C S video between the connection box and the monitor video input 6 3 SOPROTOUCH IMAGE FREEZING OPERATION When powering on the camera automatically selects the one image mode To switch to four image mode press for more than three seconds until a black flash appears on the screen SoproTouch or if you have chosen to use a footswitch press it for more than three seconds Perform the same handling to switch back to one image mode e In one image mode you just have to slightly touch SoproTouch or to briefly press the footswitch once as soon as the desired image appears on the monitor The image is automatically stored in the camera and displayed on the screen If you want to return to direct mode you just have to slightly touch the SoproTouch or press the footswitch once more Another little gentle touch of the SoproTouch or press of the footswitch will freeze another image by deleting the previous one n four image mode the image is stored in one of the quarters of the screen when you slightly touch SoproTouch or press the footswitch and remains displaye
6. holder during this period CAUTION This holder is equipped with magnets that can damage devices sensitive to magnetic fields Make sure you do not install this holder near these devices cathode ray tube video screen magnetic videotapes etc 5 2 FURTHER CONNECTION BOXES optional You can install a connection box near each dental chair no limitation You will just have to transport the handpiece from one chair to the other The handpiece holder is intended to maintain the connecting cable connector when the cable is not linked to the handpiece When you disconnect the handpiece connecting cable to take it to another chair or when you put the handpiece on its holder the last stored image displays on the screen or the last four if you were in four image mode or the color bar pattern if no image was stored Except on Dock USB2 Sopro 617 gt User manual 11 ENGLISH CONNECTING TO A VIDEO SCREEN 6 1 DOCK M_VIDEO OR DOCK M_USB2 CONNECTION Connect the video cable preferably Y C S video between the connection box and the monitor video input Connect the connecting cable between the connection box and the handpiece e If you prefer using a footswitch rather than SoproTouch to freeze the image you just have to connect the footswitch optional to the connection box With this configuration SoproTouch is inhibited Connect the power supply to the outlet and to the connection box
7. mobile RF communication devices transmitters and the recommended SOPRO device such as recommended below depending on the maximal output power of the communication device Rated maximal output Separation distance depending on the transmitter frequency power of the m transmitter 150 kHz to 80 MHz 80 MHz to 800 MHz 800 MHz to 2 5 GHz 1 16VP 1 16VP d 2 33VP For the transmitters whose maximal output is not listed above the recommended separation distance d metres m can be determined by using the equation applicable to the transmitter frequency where P is the maximal output of the transmitter in watts W rated by the transmitter manufacturer Note 1 At 80 MHz and at 800 MHz the separation distance given in the higher frequency band applies Note 2 These recommendations may not apply in every situation The electromagnetic wave propagation is modified by absorption and reflection due to the structures objects and persons 10 Sopro 617 User manual ENGLISH 0 INSTALLATION 5 1 COMMISSIONING Fastening the handpiece holder 1 Choose a plain area that can be easily accessible for use 2 Use the wipe provided to clean the surface on which you are going to fasten the holder 3 Remove the double sided tape adhesive protection that is on the holder place it and press it several times to correctly fix The maximum sticking performance is obtained after two hours so avoid any stress on the
8. 2 5 metre cable to link the handpiece to the connection box 5 and 7 metres optional An user s manual An installation manual Imaging software in demo version DOCK MU USB2 connection box with integrated image memory and digital USB output2 2 5 metre cable to link the handpiece to the connection box 5 metres and 7 metres optional An user s manual An installation manual Imaging software in demo version DOCK USB2 connection box with a 3 5 metre cable to link the handpiece to the computer USB port Imaging software in demo version An user s manual This equipment was packaged in a custom carton This carton should be kept for possible transportation As a complement of the dental camera some dental barriers necessary to the intra oral use of the camera are included For more details about these products please refer to our catalog or contact our commercial service 4 Sopro 617 User manual ENGLISH SAFETY INSTRUCTIONS Do not expose the dental camera to water spray and do not store it in a humid environment electrocution risk Install the dental camera in a clean dry and well ventilated place Disconnect the camera from the power supply if you are not going to use it for several days Do not pull on the cable Never compress or nip the handpiece cable Never expose the product to high vibrations Do not drop the camera This camer
9. 61000 4 2 Far transient bursts EN 61000 4 4 Voltage shocks EN 61000 4 5 Dips brief outages and power voltage variation EN 61000 4 11 Magnetic field with the network frequency 50 60 Hz Note U is the power voltage nominal value applied during the trial User manual 8 Sopro 617 ENGLISH Guide and declaration of the manufacturer electromagnetic immunity SOPRO device is intended to be used in the electromagnetic environment specified below The user should make sure it is used in this environment CEI 60601 Compliance Electromagnetic environment Immunity trial Severity level level Guide Portable and mobile RF communication devices should not be used at a distance from SOPRO device including the cables lower than the recommended separation distance calculated with the applicable formulas depending on the emitter frequency Recommended separation distance Conducted RF 3 Vrms 1 16VP 6 150 kHz to 80 MHz Radiated RF 3 V m d 1 16 80 MHz to 800 MHz EN 61000 4 3 80 MHz to 2 5 2 33VP 800 MHz to 2 5 GHz GHz where P is the maximum rated output of the transmitter in watts W by the transmitter manufacturer and d the recommended separation distance in metres m The field levels emitted by the fixed RF transmitters determined by an electromagnetic measurement of the site should be lower than the compliance level in each frequency band Interference may occur in the
10. DUCTION It is an intra oral camera designed for dental applications It allows visualization of anatomical and pathological details that cannot be seen with the naked eye as well as the pathology control before and after treatment Its extra light handpiece sensitivity and resolution performance as well as fidelity with respect to shades make it an ideal medical tool This dental camera is composed of a camera handpiece SOPRO 617 and a connection box DOCK M USB2 or DOCK M VIDEO MU USB2 or DOCK MU VIDEO as well as various accessories necessary for it to work SOPRO 617 10 dental barriers 1 handpiece integrating the camera electronics and lighting 1 handpiece holder DOCK M VIDEO connection box with integrated image memory Power supply 2 5 metre cable to link the handpiece to the connection box 5 metres and 7 metres optional A Y C S Video video cable An RCA video cable An user s manual Imaging software in demo version DOCK M USB2 connection box with integrated image memory and USB2 digital output Power supply 2 5 metre cable to link the handpiece to the connection box 5 metres and 7 metres optional A Y C S Video video cable An RCA video cable A USB cable An user s manual Imaging software in demo version Sopro 617 gt User manual 3 ENGLISH DOCK MU VIDEO A connection box with integrated image memory
11. FAILURE CAUSES Defective power supply Connection problem e Defective monitor power supply Connection problem Monitor configuration Hygienic protector Defective power supply Connection problem Configuration Driver Connection problem Camera driver configuration Hygienic protector PROBLEMS With a video monitor No image displays on the screen and the camera LEDs are not on The camera switches on but no image displays on the screen An image displays on the screen but the quality is not satisfactory An image displays but it is not really clear blurry With a computer No image displays on the screen and the camera LEDs are not on The camera switches on but no image displays on the screen An image displays on the screen but the quality is not satisfactory An image displays but it is not very clear blurry ENGLISH If the defect persists and you will return the dental camera to us be sure to send it in its original packaging In the same way the dental camera should be sent to us in its totality Connection box handpiece cables Then please enclose with your packing list a brief explanatory note relative to the noticed defect If some parts constituting the camera happened to break it is imperative to include everything so that the defective parts can be replaced When your material is returned to you you
12. a should in no way be immersed in any liquid nor should it be autoclaved The surface temperature in the light emission area can be just above 41 C after several minutes using it So avoid maintaining this emission area in contact with the patient s mouth The SOPRO 617 camera is a product using class LEDS according to IEC 60825 Do not stare at them in order to avoid any ocular risk For each new patient it is essential to use the dental barriers provided with the camera or provided as a complement Before using the camera make sure it does not have any sharp edges NOTE If the hygienic protection is torn while examining a patient or if the handpiece was infected while withdrawing the hygienic protector it is essential to totally disinfect the handpiece In order to do this please refer to the maintenance chapter Sopro 617 gt User manual 5 ENGLISH 0 REGULATORY REQUIREMENTS 4 1 COMPLIANCE WITH STANDARDS AND REGULATIONS This product was designed and manufactured by a company having an authorized quality system It meets the requirements of the European directive 93 42 EEC relative to medical devices Therefore it particularly meets electrical safety and electromagnetic compatibility standards IEC CEM 4 2 ELECTROMAGNETIC INTERFERENCE AND ELECTROSTATIC DISCHARGES Electromagnetic compatibility CEM is the ability of electronic device elements to correctly interact in a
13. d on the screen Another little light touch on SoproTouch or press of the footswitch will return the image to direct mode A third little light touch or press will store a second image in another quarter of the screen and so on until obtaining the four images 12 Sopro 617 User manual ENGLISH Q CONNECTING TO A COMPUTER You should start by checking that your computer meets the following minimum use requirements PC type computer PC complying with IEC 60950 e Pentium III 500 Mhz processor 20 Gb hard disk 512 Mb RAM internal storage Windows 2000 Pro SP4 XP Pro SP1 Two 2 0 Hi Speed USB ports 32 Mb RAM graphic board not shared compatible DirectX 9 e USB chipset Intel or NEC Screen resolution 1024 x 768 7 1 DOCK M USB2 OR DOCK 0582 CONNECTION Connect the USB cable between the connection box and one of the computer USB ports Connect the connecting cable between the connection box and the handpiece e If you prefer using a footswitch only DOCK M USB2 rather than SoproTouch to freeze the image you just have to connect the footswitch optionally provided to the connection box With this configuration SoproTouch is inhibited Connect the power supply to the outlet and to the connection box the green indicator light should be on only DOCK M USB2 7 2 DOCK MU USB2 CONNECTION Refer to the DOCK MU USB 2 integration manual Connect the connecting cable to the handpiece
14. e manufacturer electromagnetic immunity SOPRO device is intended to be used in the electromagnetic environment specified below The user should make sure it is used in this environment Electromagnetic environment Guide The floor should be wooden concrete or tile If the floor is covered with a synthetic material the relative humidity should be at least 30 The main power supply quality should be one of a traditional commercial or hospital environment The main power supply quality should be one of a traditional commercial or hospital environment The main power supply quality should be one of a traditional commercial or hospital environment If the user of SOPRO device requires it to continue to operate during main power supply outages it is recommended SOPRO device is fed by an inverter or a battery The magnetic field with the network frequency should be at a characteristic level of a location in a traditional commercial or hospital environment Compliance level lt 5 10 ms lt 40 U7 100 ms lt 70 U7 500 ms lt 5 Ur 5s 3 A m CEI 60601 Severity level 6 kV when in contact 8 kV in the air 2 kV for the feed cables 1 kV for the input output cables Differential mode 1 kV Common mode 2 kV lt 5 U for 10 ms 40 U 100 ms 70 U 500 ms lt 5 55 for for for 3 A m Immunity trial Electrostatic discharges EN
15. e type 0 5 8 4 VIDEO AND USB OUTPUTS This camera has two independent video outputs a composite one and a Y C S Video One of these two outputs must be connected to the monitor video input preferably Y C S Video This camera has a digital USB 2 0 output that can be connected to the USB port2 of a computer 8 5 FOOTSWITCH The footswitch should be connected here 4 you have selected it to freeze the image only available on DOCK M_USB2 and DOCK M_VIDEO For DOCK MU_USB2 DOCK MU_VIDEO please refer to the product integration instructions 16 Sopro 617 User manual ENGLISH 8 6 IDENTIFICATION The indications born on the boxes identify the dental camera according to the international standards CEI 601 1 and CEI 417 gt Video output Handpiece connection Footswitch connection Continuous voltage USB s USB2 output BF type camera Caution please consult the ACCOMPANYING DOCUMENTS Disposal of electric and electronic equipment marketed after 01 August 2005 For active medical devices this symbol is associated to the manufacturing year expressed with four digits EE pos For active medical devices this symbol is associated to the manufacturer name and address C Product compliance according to the European directive 93 42 EEC relative to medical devices 0459 Grounding The devices that connect to video or USB outputs should comply with IEC 60950
16. ect damage does not apply under the regulatory or legal rules in force in some countries and the present exclusion may not apply to a purchaser in those countries 20 Sopro 617 gt User manual ENGLISH SOLUTIONS Check the power supply is correctly connected to the network and to the connection box Check the connecting cable is correctly connected to the handpiece and to the connection box Check the video cable is correctly connected to the monitor and to the connection box 2 Check the monitor is switched on Check the video monitor configuration is correctly set up brightness contrast saturation etc Check the hygienic protector is correctly positioned on the camera head 1 Check the power supply is correctly connected to the network and to the connection box 2 Check the connecting cable is correctly connected to the handpiece and to the connection box 1 Check the camera is correctly set up in Sopro Imaging please refer to Sopro Imaging owner s manual 2 Check the camera is correctly detected in the device driver correct installation of its driver 3 Check the USB cable coming from the DOCK is correctly connected to the HUB Check the camera configuration in the Sopro Imaging software brightness contrast saturation etc Please refer to Sopro Imaging owner s manual Check the hygienic protector is correctly positioned on the camera head 21 Sopro 617 gt User manual 10 2 IN CASE OF
17. ll clean the handpiece with disinfecting wipes then roll up several disinfecting wipes around the handpiece and leave on for 15 minutes Sopro 617 gt User manual 19 ENGLISH AFTER SALES SERVICE 10 1 WARRANTIES SOPRO ensures its products to be free from material and manufacturing defects for a period of one 1 year coming into force at the purchase date This warranty does not apply to misused modified untended or accidentally damaged products or products subject to abnormal use and handling conditions The distributors other than ACTEON Group s subsidiaries are not authorized to apply a warranty more extended on behalf of SOPRO The entire liability of SOPRO is limited to its convenience when replacing or repairing free of charge the defective product if it has been sent to SOPRO After Sales Service This applies to the warranty period Out of France the access to the warranty is only possible if the product was bought in one of the points of sale authorized by SOPRO in the country where it will be used THIS WARRANTY CONSTITUTES THE ONLY AND UNIQUE REMEDY IT REPLACES ANY OTHER WARRANTY FOR EXAMPLE OF ADEQUACY TO A PARTICULAR AIM SHOULD IT BE EXPLICIT OR IMPLICIT SOPRO SHALL NOT BE LIABLE FOR ANY PARTICULAR DAMAGE INDIRECT ACCIDENTAL OR CONSEQUENT OR FOR ANY DETERIORATION OR DATA LOSS ON A CONTRACTUAL NON CONTRACTUAL OR OTHER BASIS The liability exclusion or limitation for direct or indir
18. n electronic environment Although this dental camera system was designed according to this compatibility and complies with the electromagnetic interference thresholds established by the regulatory agency there is no guarantee about the interference likely to occur on a particular installation If the device generates interference with radio communication services which can be determined by switching it off and on the user is recommended to try to correct this phenomenon by taking whole or part of the following measures Change the receiving antenna orientation Reposition the product according to the receiver Take away the computer from the receiver SOPRO 617 dental camera system is designed and tested to be used in a home environment class B Group 1 according to CISPR11 standard 4 3 MEDICAL DEVICE VIGILANCE As any medical device this device is subjected to the medical device vigilance dispositions any serious dysfunction should then be the subject of a description to the competent authorities and to the manufacturer as soon as possible and as precisely as possible 4 4 END OF LIFE This device bears the recycling symbol according to the European directive 2002 96 EC about electric and electronic equipment waste DEEE or WEEE Properly disposing of this device will contribute to avoiding any damage done to the environment or human health 6 Sopro 617 User manual ENGLISH The symbol present on the de
19. nstallation programs NOTE To obtain better performance if possible when using the Imaging SOPRO software it is recommended to install DirectX 9 0c In order to do this click on the key Install DirectX 9 0c and then follow the displayed instructions DirectX 9 0c is a Microsoft product In case of difficulties when installing this product consult the information provided by this editor In order to ensure maximal compatibility with all the installed systems computers Windows and word processing version it was decided to provide the documents available on the CD ROM in PDF format This format developed by ADOBE Company can be read with the Acrobat Reader service program If Acrobat Reader is not installed on the computer or the version is not recent enough click on the key Install Acrobat Reader and then follow the instructions Acrobat Reader is an ADOBE product In case of difficulties when installing this product consult the information provided by this editor 14 Sopro 617 User manual ENGLISH A dialog box opens it is the main menu window allowing the installation of a certain number of programs related to SOPRO Imaging application Click on Install SOPRO Imaging A window displays select the desired language during the installation process A dialog box opens It displays the software license to be entirely read to continue the installation Once the
20. produced or transmitted in any form without the prior permission of SOPRO SIRA 04 94 74 00 09 Ps e Ro ACTEON Imaging ZAC Ath lia Avenue des Gen vriers 13705 LA CIOTAT cedex FRANCE T l 33 0 442 98 01 01 gt Fax 33 0 442 71 76 90 E mail info sopro acteongroup com www sopro acteongroup com
21. should check its condition and note any reservation on the delivery slip if necessary You then have 48 hours to confirm by registered letter sent to the carrier After this period the carrier will be able to deny these reservations If any material returned to you is damaged during transportation the repair charges will be billed to either the carrier if the reservations were made within the period or the recipient So confirm as soon as possible that all materials are working properly 22 Sopro 617 User manual 23 User manual ENGLISH TECHNICAL FEATURES SOPRO 617 high sensitivity CCD 1 4 Resolution 752 x 582 PAL 768 x 494 NTSC Definition 470 lines Sensitivity 2 lux Lighting 8 LED Adjustments automatic Non inverted image e Freeze image using SoproTouch or foot control optional angle of view 80 e handpiece dimensions L 205 W 28 24 mm Distal part dimensions W 16 5 H 10 8 mm Handpiece weight 55g applied part of BF type DOCK M_USB2 Memory 1 and 4 images Power supply 110 V 230 V 60 Hz 50 Hz Consumption 9 VA 1 PAL or NTSC video output 1 PAL or NTSC S video output 1 digital USB output 2 0 Controller dimensions L 145 W 130 35 mm Controller weight 245 DOCK M VIDEO Memory 1 and 4 images Power supply 110 V 230 V 60 Hz 50 Hz Consumption 9 VA
22. standard Sopro 617 gt User manual 17 ENGLISH MAINTENANCE For each new patient it is essential to use the dental barriers provided with the camera or provided as a complement Before first using it it is imperative to follow the complete disinfecting procedure Any intra oral camera returning from service or maintenance should follow the complete disinfecting procedure before being used WARNING Do not use products containing Ammoniac trichloroethylene Dichloroethylene Ammonium hydrochlorid Chlorinated and aromatic hydrocarbon Ethylene dichloride Methylene chloride Ketones Deterioration risks of the plastic parts WARNING Do not directly spray disinfecting products on SOPRO products 18 Sopro 617 gt User manual ENGLISH 9 1 HANDPIECE AND CONNECTION BOX MAINTENANCE DESCRIPTION RECOMMENDATIONS USE INSTRUCTIONS AND PRECAUTIONS X Disinfecting Surface cleaning and Take the wipe wring it disinfecting wipes of X Do not scrub and then scrub the X Do not rinse Wipes Septol type equipment until obtaining X Do not immerse in visible cleanliness a disinfecting v Allow to dry in the open liquid air Carefully close the packaging box Pierre Rolland NOTE In case of contact with blood or important soiling it is strongly recommended to follow a disinfecting process First of a
23. vice or on the accompanying documentation indicates this product cannot be any case treated as household waste Therefore it should be given to a waste collection centre in charge of electric and electronic equipment recycling For scrapping respect the standards relative to waste disposal in force in the installation country For more details about the device treatment recuperation and recycling please contact your dental device distributor or failing that the group ACTEON site so that you can be provided the proper procedure 4 5 ELECTROMAGNETIC COMPATIBILITY Guide and declaration of the manufacturer electromagnetic emissions SOPRO device is intended to be used in the electromagnetic environment specified below The user should make sure it is used in this environment Emission trial Compliance Electromagnetic environment Guide RF emissions SOPRO device only uses radio energy for its CISPR 11 internal functions Therefore its RF emissions are very low and are not likely to cause interference with near electronic devices RF emissions Class B SOPRO device may be used in every domestic CISPR 11 premises including the ones directly connected to the public low voltage power distribution network used to supply household buildings Harmonic emissions No applicable EN 61000 3 2 Voltage fluctuations No applicable Flicker EN 61000 3 3 Sopro 617 gt User manual 7 ENGLISH Guide and declaration of th
24. vicinity of the devices bearing the following symbol 2 Note 1 At 80 MHz and 800 MHz the higher frequency band applies Note 2 These recommendations may not apply in every situation Electromagnetic wave propagation is modified by the absorption and reflection due to the structures objects and persons Sopro 617 gt User manual 9 ENGLISH The fixed transmitter field levels such as the base stations of the radio telephones cellular wireless and the terrestrial mobile radios amateur radio AM FM and TV radio communication cannot be theoretically assessed precisely To obtain the electromagnetic environment due to the fixed RF transmitters a site measurement should be performed If a field level measured in the use environment of SOPRO device exceeds the compliance levels above applicable the good operation of SOPRO device should be checked If abnormal operations are proved some further measures should be taken such as reorientation or relocation of the standard device b Above the 150 kHz to 80 MHz frequency band the field level should be lower than 3 V m Recommended separation distances between the portable and mobile RF communication devices and SOPRO device SOPRO device is intended to be used in an electromagnetic environment in which the irradiated RF disturbances are checked The user of SOPRO device can help to avoid electromagnetic interference by maintaining a minimal distance between the portable and

Download Pdf Manuals