1. Names cannot contain any special characters such as umlauts parentheses underscores forward or backward slashes empty spaces etc The dash is the only special character allowed Names must not begin or end with the or characters Names must not have the format n n n n where n 0 999 The device name must not start with numbers Names must not begin with the character sequence port xyz where x y z 0 9 If you want to change the IP address in non volatile memory please refer to Chapter3 Editing Ethernet Nodes Copyright C CREVIS Co Ltd Support 82 31 273 6453 URL www crevis co kr CREVIS 19 FnIO PROFINET Adapter NA 9187 FnlO S Series Device names are assigned to PROFINET IO device when the device is being set up and placed in operation for the first time Commissioned The default name is NA9187 SW see Short Designation If several devices of the same type are arranged on the same PROFINET IO system then STEP7 automatically adds sequential number to the name from the GSD file In this case the second device has the extension 1 the third one has the extension 2 etc Communication Speed Setting See Master Module Setting about communication speed setting ATTENTION MAC ID addresses have to be unique throughout the entire interconnected networks Copyright C CREVIS Co Ltd Support 82 31 273 6453 URL www crevis co kr CREVIS 20 FnIO PROFINET Adapt
2. GSDML V2 0 CREVIS NA918 20081 231 xml 27317 00 English GSDML V2 0 Crevis N49187 20090101 xml 2017 DO i English gsdml v2 O wago series 750_753 200701 15xml 01 15 2007 12 00 00 AM i English German GSDML V2 2 Siemens DevKit 20080719 xml 07 19 2008 12 00 00 AM E English German st Show Log Select All Deselect All Close eo Browse button Click the Browse button to navigate to the GSDML file The field below the button displays the GSDML files in this folder with file name release number version as well as the languages available the GSDML file O Install button Click the Install button to start to install the NA9187 GSDML file Copyright C CREVIS Co Ltd Support 82 31 273 6453 URL www crevis co kr CREVIS 22 FnIO PROFINET Adapter NA 9187 FnlO S Series e Show Log button Click the View Log button to display a log of the previous installation procedure During the installation STEP 7 creates a log file in which all the files selected for installation are listed along with their statuses If one or more GSDML files were already available or errors occurred during the installation this information is listed in the log file O After installation of GSDML file You can then find the NA9187 device in the standard catalog as below picture Find fo Profile Standard PROFIBUS DP 82 PROFIBUS PA SE PROFINET IO 3 Additional Field Devices 3 1 0 9 BK Device 5 CREV
3. Pa Close Copyright C CREVIS Co Ltd Support 82 31 273 6453 URL www crevis co kr CREVIS 26 FnIO PROFINET Adapter NA 9187 FnlO S Series e IP configuration STEP 1 Find out the MAC addresses of the available devices using the Browse button or enter the MAC address assuming you know it Browse Network 2 Nodes Start IP address MAC address Device name 32 168 0 248 00 00 00 REVIS Fn nadir 192 168 0 254 00 01 05 02 24 11 BK Device bk9103 2 IV Fast search MAC address SSS Cancel Help STEP 2 If this is the case select the module with the known MAC address from the list displayed in the dialog after browsing the network STEP 3 Set the IP configuration select from the following alternatives Use IP parameters If you opened the dialog based on a selected module the IP address already has the values configured for the module Otherwise you must enter the IP address subnet mask and if applicable the gateway Obtain IP address from a DHCP server If you select this option the IP address is obtained from a DHCP server Depending on the selected option the DHCP server is informed of the MAC address of the CP the device name or the client ID that you can enter here The client ID is a string with a maximum of 63 characters Only the following characters can be used a z A Z 0 9 and dash If you specify here that the DHCP server should obtain the IP address using a device name you m
4. s fault action parameters Stop the FnBus communication Reaction on FnBus error Clear input image The input image is clear to 0 Hold last image The input image remain the last valid value Auto reset NA9187 performs reset Disconnect PROFINET Stop the communication with Controller Default settings Copyright C CREVIS Co Ltd Support 82 31 273 6453 URL www crevis co kr CREVIS FnIO PROFINET Adapter NA 9187 6 2 6 2 1 Device identity FnlO S Series NA 9187 PROFINET IO Characteristics Item Value Vendor CREVIS Vendor ID 0x0140 Product family CREVIS FnlO System Device ID 0x9187 Details NA9187 PROFINET IO Device 6 2 2 Device Access Point Copyright C Item Value Module Ident Number 0x00009187 Details NA9187 PROFINET IO Device Vendor Name CREVIS Order Number NA9187 Category FnIO Network Adapter Software Version V20 000 Hardware Version V20 000 Maximal Input Length 252 Bytes Maximal Output Length 252 Bytes Physical Slots 0 32 Minimal Device Interval 4 ms Based on NS9360 DNS Compliant Name NA9187 xx Supports Extended Assignment of IP Address No Fixed in Slots 0 Instance Field of the Object UUID 1 Supports Multiple Write No Requires IOPS IOCS Yes Requires Engineering tool which supports at least V2 0 GSDML Version CREVIS Co Ltd Support 82 31 273 6453 CREVIS URL www crev
5. 2 3 5 Port1 Port2 Link and Activity State LED is To indicate Link Down Off Link is down Active Flashing Green Active is present Link UP Green Link is up Physical connection is established Copyright C CREVIS Co Ltd Support 82 31 273 6453 URL www crevis co kr CREVIS 12 FnIO PROFINET Adapter NA 9187 3 Dimension 3 1 NA 9187 70 Copyright C CREVIS Co Ltd Suppor 82 31 273 6453 URL www crevis co kr FnlO S Series CREVIS 13 FnIO PROFINET Adapter NA 9187 FnlO S Series 4 Mechanical Set Up 4 1 Total Expansion The number of the module assembly that can be connected is 32 So the maximum length is 426mm Exception ST 2748 is excepted to calculate maximum length because that is double width module 4 2 Plugging and Removal of the Components DANGER Before work is done on the components the voltage supply must be turned off Unlock As above figure in order to safeguard the FnIO module from jamming it should be fixed onto the DIN rail with locking level To do so fold on the upper of the locking lever To pull out the FnIO module unfold the locking lever as below figure Copyright C CREVIS Co Ltd Support 82 31 273 6453 URL www crevis co kr CREVIS FnlO S Series FnIO PROFINET Adapter NA 9187 14 Internal FnBus Field Power Contacts Communication between the NA series and the expansion module as
6. 3 1 A E A EN 4 Mechanical Set Up aaa 4 1 Total Expansion N EE EE EE 4 2 Plugging and Removal of the Components Copyright C CREVIS Co Ltd Support 82 31 273 6453 URL www crevis co kr FnlO S Series EE ante 13 CREVIS 4 FnIO PROFINET Adapter NA 9187 FnlO S Series 4 3 Internal FnBus Field Power Contacts ee ee ee ee ee ee ee ee canon ee ee ee ronca ee 14 5 PROFINET Electrical Interface ee Se N ee ie eg ee eg 15 5 1 a A s N EE Ee er ete ee 15 5 2 PROFINET Electrical Interface minar 17 52l A e EE EE EE OE ENE EG 17 5 2 2 PROFINET Parameterization by Rotary Switch i e sesse seek esse gesek see eek eek ee eke 18 s3 T O Process Image Map ii A AA N ee de 20 5 3 Example Configuration with SEIMENS PLC STEP7 ssssscsssscssssscssseccssecssseccssseesssecssseeesseecs 21 5 3 1 Example GSDML SENG ia 21 5 3 2 Example Assign the device name sesse sek ese gesek Ge GER Geek ee GER ee Rek ee eke 23 5 3 3 Example Editing Ethernet Nodes in non volatile Memory sesse seek eek ee ee ee 25 5 3 4 Parameters IO cycle time and port option with STEP7 uu sesse seek sees seek eek eek ee 28 6 NA 9187 PROFINE cornada 32 6 1 NA 9187 Parametros 32 6 2 NA 9187 PROFINET IO Character sanador ia 33 6 21 Device identity sn ES AA ARA 33 6 2 2 Device Access PO naaa 33 6232 gt SU Sl of NA 9187 eN Ge NG ee oman ee 34 7 Trouble Shooting aaa ia 35 7 1 How to diagnose by LED dit iaa 35 APPENDIX AAA AAA AAA AA AAA 37 A 1 Prod
7. 41 47 82 Active ST 3134 4 Channels Current 0 20mA 14bit 41 43 1E Active ST 3214 4 Channels Current 4 20mA 12bit 41 43 1D Active ST 3218 8 Channels Current 4 20mA 12bit 41 47 83 Active ST 3234 4 Channels Current 4 20mA 14bit 41 43 IF Active ST 3274 4 Channels Current 4 20mA 12bit Sensor Connector 41 43 A3 Active ST 3424 4 Channels Voltage 0 10Vdc 12bit 41 43 20 Active ST 3428 8 Channels Voltage 0 10Vdc 12bit 41 47 22 Active ST 3444 4 Channels Voltage 0 10Vdc 14bit 41 43 22 Active ST 3474 4 Channels Voltage 0 10Vdc 12bit Sensor Connector 41 43 AO Active ST 3524 4 Channels Voltage 10Vdc 10Vdc 12bit 41 43 21 Active ST 3544 4 Channels Voltage 10Vdc 10Vdc 14bit 41 43 23 Active ST 3624 4 Channels Voltage 0 5Vdc 12bit 41 43 24 Active ST 3644 4 Channels Voltage 0 5Vdc 14bit 41 43 25 Active ST 3702 2 Channels RTD Status 41 41 28 Active ST 3704 4 Channels RTD Status 41 43 64 Active ST 3708 8 Channels RTD Status 41 47 65 Active ST 3802 2 Channels TC 41 41 2A Active ST 3804 4 Channels TC 41 43 66 Active ST 3808 8 Channels TC 41 47 67 Active Analog Output Module ST 4112 2 Channels Current 0 20mA 12bit 8l 41 2C Active ST 4114 4 Channels Current 0 20mA 12bit 81 43 6D Active ST 4212 2 Channels Current 4 20mA 12bit 8l 41 2D Active ST 4214 4 Channels Current 4 20mA 12bit 81 43 6E Active ST 4274 4 Channels Current 4 20mA 12bit Sensor Connector 81 43 B3 Active ST 4422 2 Channels Voltage 0 10Vdc 12
8. FnlO S Series APPENDIX A A 1 Product List No ST Number Description ID hex Production Status Digital Input Module ST 1114 4 Points Sink Positive 5Vdc 41 00 01 Active ST 111F 16 Points Sink Positive 5Vdc 41 01 19 Active ST 1124 4 Points Source Negative 5Vdc 41 00 02 Active ST 112F 16 Points Source Negative 5 Vdc 41 01 1A Active ST 1214 4 Points Sink Positive 12V 24Vdc 41 00 03 Active ST 1218 8 Points Sink Positive 12V 24Vdc 41 00 07 Active ST 121F 16 Points Sink Positive 12V 24Vdc 41 01 13 Active ST 1224 4 Points Source Negative 12V 24Vdc 41 00 04 Active ST 1228 8 Points Source Negative 12V 24Vdc 41 00 08 Active ST 122F 16 Points Source Negative 12V 24Vdc 41 01 14 Active ST 1314 4 Points Sink Positive 48 Vdc 41 00 05 Active ST 131F 16 Points Sink Positive 48Vdc 41 01 17 Active ST 1324 4 Points Source Negative 48Vdc 41 00 06 Active ST 132F 16 Points Source Negative 48Vdc 41 01 18 Active ST 1804 4 Points 110Vac 41 00 09 Active ST 1904 4 Points 220Vac 41 00 OA Active Digital Output Module ST 2114 4 Points TTL Inverting 5Vdc 20mA 81 00 OD Active ST 2124 4 Points TTL Non Inverting 5Vdc 20mA 81 00 OF Active ST 221F 16 Points Sink Negative Logic 24Vdc 0 5A 81 01 15 Active ST 222F 16 Points Source Positive Logic 24Vdc 0 5A sl 01 16 Active ST 2314 4 Points Sink Negative Logic 24Vdc 0 5A 81 00 OE Active ST 2318 8 Points Sink Negative Logic 24Vdc 0 5A 81 00 11 Active ST 2
9. Size 252 Bytes inputs 252 Bytes outputs Indicators 1 green red MOD Status Indicator 1 green red NET Status Indicator 1 green red I O Status Indicator 1 green Portl Link Active Status Indicator 1 green Port2 Link Active Status Indicator 1 green Field Power Status indicator Baud rate 100Mbps Full Duplex Module Location Starter module Left side of FnIO System Copyright C CREVIS Co Ltd Support 82 31 273 6453 URL www crevis co kr CREVIS 10 FnIO PROFINET Adapter NA 9187 FnlO S Series 2 3 LED Indicator 2 3 1 Module Status LED MOD State LED is To indicate No Power Off No power is supplied to the unit OS Handle Error ia Green OS handle unexpected exceptions Wrong IP address Flashing Green 1s IP address is 0 0 0 0 Device Operational Green The unit is operating in normal condition OS Fatal Error Flashing Red 0 2s OS Fatal error is occurred Invalid RAM Image Flashing Red Is Invalid RAM Image User fatal error Red Invalid boot image header Flash ROM Boot loader 2 3 2 Network Status LED NET State LED is To indicate Not Powered bis Not On line Off Device is not on line or may not be powered On line Flashing Green PROFINET IO connection has been established Not connected 0 2s Wait parameters Data Exchange Stop Flashing Green 1s PROFINET IO data exchange stop On line Green Device is on line and allocated to a master Connected Invalid
10. or warnings can occur fixed factor You can sets the reduction ratio with which the NA 9187 is updated for example factor 4 for update every fourth send clock pulse Properties NA9187 X1 General Addresses 10 Cycle Update Time Mode fixed factor y Factor Send clock ms Update time ms 4 000 vi 14 x x 1 000 Watchdog Time Number of accepted update cycles with missing IO data Watchdog time ms Update time ms The update time can only be changed when there are no synchronized PROFINET IO devices in the IO system Factor Reduction ratio Send clock ms Send clock set in the sync domain Number of accepted update cycles with missing IO data To make adaptations in problem situations you can change the default number of accepted update cycles with missing IO data for example during commissioning This action will also indirectly change the watchdog time In much the same way as in a PROFIBUS system exceeding the watchdog time will result in an error reaction the IO device switches its outputs to a safe state Watchdog Time The watchdog time is computed as follows Product of Update Time x Number of accepted update cycles with missing IO data Copyright C CREVIS Co Ltd Support 82 31 273 6453 URL www crevis co kr CREVIS 30 FnIO PROFINET Adapter NA 9187 FnlO S Series e Port 1 or Port 2 Topology Tab If you double click Slot 0 X1 P1 or Slot 0 X1 P2 you can see the p
11. well as system field power supply of the bus 4 3 ternal bus It is comprised of 6 data pin and 2 field power pin modules is carried out via the in N a hd Field Power Pins Data Pins DANGER Do not touch data and field power pins in order to avoid soiling and damage by ESD noise CREVIS CREVIS Co Ltd Support 82 31 273 6453 URL www crevis co kr Copyright C 15 FnIO PROFINET Adapter NA 9187 FnlO S Series 5 PROFINET Electrical Interface 5 1 FnBus System User Interface Fn Bus Interface Processor Expansion Module Module E 1 Network Serial Service Messaging Communication Protocol Configuration Tool Soft PLC Master Di Net Vec SV eviceNel END Token Output Serial Output Serial Input CANopen Network Reserved Adapter Module Slot 1 EA Network Expansion Adapter Module Module Field GND OVdc Field Vcc 24Vdc ModBus LILT e Network Adapter Module The Network Adapter Module forms the link between the field bus and the field devices with the Expansion Modules The connection to different field bus systems can be established by each of the corresponding Network Adapter Module e g for SyncNet PROFIBUS CANopen DeviceNet Ethernet IP CC Link MODBUS Serial MODBUS TCP etc Copyright C CREVIS Co Ltd Support 82 31 273 6453 URL www crevis co kr CREVIS 16 FnIO PROFINET Adapter NA 9187 FnlO S Series e Expansion Module The Expansion Modules a
12. 1 FnIO PROFINET Adapter NA 9187 FnlO S Series PROFINET Adapter NA 9187 User Manual e 2 ad WE dd Ad ar e de 2 Version 1 02 2012 CREVIS Co Ltd Copyright C CREVIS Co Ltd Support 82 31 273 6453 URL www crevis co kr CREVIS 2 FnIO PROFINET Adapter NA 9187 FnlO S Series DOCUMENT CHANGE SUMMARY REV PAGE REMARKS DATE EDITOR New 1 0 2011 10 21 JE Kang Document 5 Add your experience 2012 1 13 JE Kang 1 01 6 Changed Certification 17 Add to Cable Add Example GSDML setting 1 02 2012 2 13 JE Kang Changed 6 2 and Trouble shooting LED Changed Cover 2012 2 28 JE Kang Copyright C CREVIS Co Ltd Support 82 31 273 6453 URL www crevis co kr CREVIS 3 FnIO PROFINET Adapter NA 9187 CONTENTS I DOME NOtES be ER ke RI ek ee ek ees Roe ee 1 1 Safety Instructi ON EO ee N LLL SYMBOIS oe es ee Oe rrerree 1 1 2 ie AE N N 1 1 3 Certification EE EE cystnebstendicvadsinetd deasubiaaviies 2 Specification EE EE OE N 21 The Interface RO nidad lin 2 1 1 AE ER EN 2 2 Specification AAA ee annen 2 2 1 General Specifications 2 2 2 Interface Specification uses sek ese eek eek ER eek GER Ge ee eke 2 3 LED Indicato resne ea AAEE 2 3 1 Module Status LED MOD urraca 23 2 Network Status LED NET aia sine ee ee 2 3 3 Expansion Module Status LED I O siii 2 3 4 Field Power Status LED aaa 2 3 5 Portl Port2 Link and Activity eie ie ie N ee 3 DIMENSIO para ii tia
13. 273 6453 URL www crevis co kr CREVIS 35 FnIO PROFINET Adapter NA 9187 FnlO S Series 7 Trouble Shooting 7 1 How to diagnose by LED indicator LED Status Cause Action No power Check main power Cable All LED turns off Contact Sales team and send module System power is not supplied for repair MOD LED flashes green Failure of initialization EEPROM Con Sales team and send module parameter for repair Excess of IO size Use expansion slot up to 32 Wrong IO composition Compose that IO total size is not MOD LED flashes red e re Occurrence of EEPROM checksum excess error Check composition I O Module MOD LED is red Wrong eii ed o HALES Sales team and send module Occurrence critical error in firmware for repair VO LED turns off Failure of Tealization expansion Module Check Connector status both NA None expansion Module series and expansion module Check communication cable with Failure of configuration baud rate Master Check power for master Use expansion slot up to 32 I O LED flashes red Compose that IO total size is not Excess of expansion slot excess Failure of initialization VO NA series notice unidentified expansion module ID Check status of expansion module heck status of ion I VO LED is red Failure of exchanging I O data mae aus of pansion connection heck mai f t d NET LED turns off Failure of communicatio
14. 324 4 Points Source Positive Logic 24Vdc 0 5A 81 00 10 Active ST 2328 8 Points Source Positive Logic 24Vdc 0 5A 81 00 12 Active ST 2414 4 Points Sink Negative Logic 24Vdc 0 5A Diagnostics 81 00 08 Active ST 2424 4 Points Source Positive Logic 24Vdc 0 5A Diagnostics C1 00 00 38 Active ST 2514 4 Points Sink Negative Logic 24 Vdc 2A Diagnostics C1 00 00 35 Active ST 2524 4 Points Source Positive Logic 24Vdc 2A Diagnostics C1 00 00 36 Active ST 2614 4 Points Sink Negative Logic 24Vdc 2A 81 00 3B Active ST 2624 4 Points Source Positive Logic 24Vdc 2A 81 00 3C Active ST 2742 2 Points 230Vac 2A 24Vdc 2A Relay sl 00 OB Active ST 2744 4 Points 230Vac 2A 24Vdc 2A Relay 81 00 51 Active ST 2748 8 Points 230Vac 2A 24Vdc 2A Relay 81 00 50 Active Copyright C CREVIS Co Ltd Support 82 31 273 6453 URL www crevis co kr CREVIS 38 FnIO PROFINET Adapter NA 9187 FnlO S Series ST 2792 2 Points 230Vac 2A 24Vdc 2A Relay Manual Auto Cl 00 01 BE Active ST 2852 2 Points 12 125Vac 0 5A Triac 81 00 OC Active ST 2924 4 Points 24Vac 2A 24Vdc 2A 4 Points 4COM 81 00 CO NEW ST 2944 4 Points 24Vac 2A 24 Vdc 2A 1 Points 1COM 81 00 Cl NEW ST 2734 4 Points 24 220Vac dc 0 5A 1 Points 1COM sl 00 C2 NEW Analog Input Module ST 3114 4 Channels Current 0 20mA 12bit 41 43 1C Active ST 3118 8 Channels Current 0 20mA 12bit
15. Co Ltd Support 82 31 273 6453 URL www crevis co kr CREVIS 24 FnIO PROFINET Adapter NA 9187 FnlO S Series O Device Name When the rotary switch is not set to non zero 1 99 If the decimal value of the rotary switch is not zero 0 the name of device will be fixed as NA9187 xx xx 1 99 You must put the fixed device name Refer to page 18 e GSD File The name of the GSDML file that is being used by STEP 7 to represent IO device and show its properties If several NA 9187 GSDML files with different versions or releases are available in the STEP 7 data management then the file with the latest GSDML schema version release number is used to represent this device in the Hardware Catalog Click the Change release number button to display a dialog box in which you can access other versions and releases of GSDML files This allows you to conveniently configure earlier NA 9187 devices or new NA 9187 devices Nodes on a PROFINET IO system Device number the number of the NA 9187 device You can use SFCs to evaluate the device number in the user program In addition to the device number the associated IO system also shown IP address The IP address for the NA 9187 is normally automatically assigned by STEP 7 This address is based on the IP address of the IO controller This automatically configured IP address is downloaded along with the hardware configuration to the IO controller The IO controller assigns the IP address to
16. Configuration Flashing Red 0 2s Invalid Configuration Minor Fault Flashing Red 1s PROFINET IO Connection is aborted after Data exchange Fault RED PROFINET IO connection is aborted before a data exchange Copyright C CREVIS Co Ltd Support 82 31 273 6453 URL www crevis co kr CREVIS 11 FnIO PROFINET Adapter NA 9187 FnlO S Series 2 3 3 Expansion Module Status LED I O State LED is To indicate Not P d ca Module Off Device has no expansion module or may not be powered Fn Bus On line Fn Bus is on line but does not exchanging I O data Flashing Green i Do not Exchanging I O Passed the expansion module configuration Fn B ti ot oe Green Expansion Slot is connected and run exchanging I O data Run Exchanging IO One or more expansion module occurred in fault state FnBus connection fault Changed expansion module configuration l Red FnBus communication failure during exchanging IO Word data type error Parameter setting error Failed to initialize expansion module Detected invalid expansion module ID Expansion Flashing Red Overflowed Input Output Size Configuration Failed 2 3 4 Field Power Status LED Too many expansion module Initial protocol failure Mismatch vendor code between adapter and expansion module State LED is To indicate Not Supplied Field eis eae Off Not supplied 24V de field power Power Supplied Field Power Green Supplied 24V dc field power
17. Copyright C CREVIS Co Ltd Support 82 31 273 6453 URL www crevis co kr CREVIS 28 FnIO PROFINET Adapter NA 9187 FnlO S Series 5 3 4 Parameters IO cycle time and port option with STEP7 In HW configuration there are several slots for a node 1 NAS187 1 Slot 3 Module Order Number NA9IB7 5 NA9IB7 449787 TAE IF IES mm j Port 2 LEIA EA lg ST 2518 ST 2318 IEE ST 2318 HE ESS If you double click the specific sub slot you can set the parameters of each NA 9187 sub slot Slot 0 gt You can set the parameters of NA 9187 Slot 0 X1 gt You can set IO Cycle time Slot 0 X1 P1 gt You can set the settings for port 001 Slot 0 X1 P2 gt You can set the settings for port 002 Parameters for NA 9187 itself If you double click Slot 0 you can set the parameters of NA 9187 Properties NA9187 1 General Addresses Parameters akon my NA9167 Parameters 2 Word data format LE Stop action epends on 10 s fault action parameters LE Reaction on FnBus Error Auto Reset Copyright C CREVIS Co Ltd Support 82 31 273 6453 URL www crevis co kr CREVIS 29 FnIO PROFINET Adapter NA 9187 FnlO S Series e IO Cycle If you double click Slot 0 X1 you can see the IO Cycle Tab The following can be set automatic STEP 7 finds the best solution for the user The update time is kept as short as possible and as high as necessary so that no errors
18. FINET Parameterization by Rotary Switch Value Description Factory settings Name of station will be read from flash memory 0 For example NA9187 1 Name of station NA9187 00 IP address will be read from flash memory IP address 192 168 0 254 Name of station will be NA9187 xx Subnet mask 255 255 255 0 1 99 xx is the value of Rotary Switch Gateway 192 168 0 1 IP address will be read from flash memory When the rotary switch is not set to non zero 1 99 If the decimal value of the rotary switch is not zero 0 the name of device will be fixed as NA9187 xx xx 1 99 You must put the fixed device name AS gt OP 2 1 o X 10 MSD EL Gy F a Qe X 1 LSD SETS 9 When the rotary switch is set to zero 0 If the decimal value of the rotary switch set to zero 0 the device name will be read from nonvolatile memory You should put the same name as the name from non volatile memory If you want to read the name in non volatile memory please refer to Chapter 3 Editing Ethernet nodes NA 1987 Devices on a PROFINET subnet must have unique names The device names must satisfy DNS naming conventions This means that the following rules must be observed Names are limited to a total of 127 characters letters numbers dashes or dots Any component part that is a character string between two dots of the device name may only be up to 63 characters long
19. IS FnlO System CJ FnlO Network Adapter DES Analog Input Analog Output Communication I F 10 D D H igital Input igital Output igh speed counter 10 ad a a a a Cc id eo ba itt t Copyright C CREVIS Co Ltd Support 82 31 273 6453 URL www crevis co kr CREVIS 23 FnIO PROFINET Adapter NA 9187 FnlO S Series 5 3 2 Example Assign the device name Insert a NA9187 node in your HW configuration and add the expansion IO modules according to your real configuration If you double click the node in HW configuration a Properties dialog is appeared You can set the name of the NA9187 and IP address Properties NA9187 General Short description NA9187 SW NA9187 PROFINET IO Device Order No Firmware NAS187 1 000 Family CREWIS FnlO System Device name NA9187 GSD file GSDML Y2 0 CREVIS N49187 20081223 xml Change Release Number Node PN IO system Device number 1 y PROFINET 10 System 100 IP address 192 168 0 248 Ethernet r Comment mm O Short description The DNS compatible name NA9187 SW from GSDML file will be displayed Here you will find a short description about the NA 9187 device to the extent that this is available in the GSDML file NA9187 PROFINET IO Device O Order no Firmware The order no and Firmware version from GSDML file will be displayed This firmware version could be differ from the version of real NA 9187 device Copyright C CREVIS
20. If necessary you can enter fixed port settings here By default Automatic setting is already selected Usually this setting will provide smooth problem free communication Caution Ensure that the setting for the local port and the partner port are identical Y Automatic settings Recommended default setting for the port The transmission settings are automatically negotiated with the partner port Auto negotiation is also automatically enabled with this setting v TP ITP 100Mbps full duplex The effect depends on the setting Disable auto negotiation Disable auto negotiation check box This check box can only be controlled when you have selected a concrete medium TP ITP with 100 Mbps full duplex The check box has no effect with the automatic setting When the check box is selected the defined setting of the port is forced such as required for a quick start of the NA 9187 You need to ensure that the partner port has the same settings Copyright C CREVIS Co Ltd Support 82 31 273 6453 URL www crevis co kr CREVIS 32 FnIO PROFINET Adapter NA 9187 FnlO S Series 6 NA 9187 PROFINET 6 1 NA 9187 Parameter Parameter Setting Description Word data type MOTOLORA Big Endian format MSB LSB INTEL Little Endian format LSB MSB Stop action Clear output image to 0 All outputs are set to 0 Hold last valid output image All outputs are remain the last value Depends on IO
21. L www crevis co kr CREVIS 2 2 Specification FnIO PROFINET Adapter NA 9187 2 2 1 General Specification General Specification FnlO S Series System Power Supply voltage 24Vdc nominal Supply voltage range 11 28 8Vdc Protection Output current limit Min 1 5A Reverse polarity protection Power Dissipation 115mA typical 24Vdc Current for I O Module 1 5A SVdc System power to internal logic Non isolation Isolation i System power to I O driver Isolation Field Power Supply voltage 24Vdc nominal Supply voltage range 11 28 8Vdc Current in Jumper Contacts DC 10A Max Weight 150g Module Size 45mm x 99mm x 70mm Environment Condition Environmental Specifications Refer to Environment Specification Surrounding Temperature 0 to 50 C Operating Temperature 0 to 50 C Storage Temperature 25 to 85 C Relative Humidity 90 non condensing Protection Class IP 20 Mounting Copyright C CREVIS Co Ltd Support 82 31 273 6453 URL www crevis co kr DIN rail CREVIS FnIO PROFINET Adapter NA 9187 2 2 2 Interface Specification Interface Specification NA 9187 FnlO S Series Protocol PROFINET I O RT DCP SNMP LLDP Station Type PROFINET IO Device Topology Line or Star topology Number of Nodes Limited by the IP address Number of Expansion I O slots Max 32 slots I O Data
22. ST 5641 1 CH Pulse output 0 5A 24Vdc source Cl 05 03 92 Active ST 5642 2 CH Pulse output 0 5A 24Vdc source Cl 09 07 90 Active ST 5651 1 CH Pulse output RS422 Cl 05 03 98 Active Power Module ST 7408 8 Channels Shield ID Type 02 00 E4 Active ST 7508 8 Channels Common OVdc ID Type 02 00 ES Active ST 7511 1 Channel Expansion Power Input 24Vdc Output 1 0A 5Vde ID Type 02 00 EO Active ST 7518 8 Channels Common 24Vdc ID Type 02 00 E6 Active ST 7588 8 Channels Common OVdc and 24Vdc ID Type 02 00 E7 Active ST 7641 1 Channel Field Distributor 5Vdc 48 Vdc 02 00 E2 TE 110Vac 220Vac ID Type A 2 Glossary System Power The power for starting up CPU Field Power The power for input and output line Terminator Resistor Resistor for prevention reflected wave EDS Electronic Data Sheet sinking The method of input and output what device does not have power source sourcing The method of input and output what device have power source Copyright C CREVIS Co Ltd Support 82 31 273 6453 URL www crevis co kr CREVIS
23. bit sl 41 2E Active ST 4424 4 Channels Voltage 0 10Vdc 12bit 81 43 6A Active ST 4474 4 Channels Voltage 0 10Vdc 12bit Sensor Connector 81 43 BO Active ST 4491 1 Channel Voltage 0 10Vdc 12bit Manual Type Cl 40 41 BF Active ST 4522 2 Channels Voltage 10 10Vdc 12bit 81 41 2F Active ST 4622 2 Channels Voltage 0 SVdc 12bit 81 41 30 Active ST 4911 1 Channel Current 0 1A 12bit 81 40 31 Active Copyright C CREVIS Co Ltd Support 82 31 273 6453 URL www crevis co kr CREVIS 39 FnIO PROFINET Adapter NA 9187 FnlO S Series Special Module ST 5101 1 Channel High Speed Counter 5V Input Cl 01 05 34 Active ST 5111 1 Channel High Speed Counter 24V Input Cl 01 05 39 Active ST 5112 2 Channel High Speed Counter 24V Sink Input Cl 01 07 4D Active ST 5114 4 Channel High Speed Counter 24V Sink Input Cl 03 OF 4C Active ST 5211 RS232 Communication 1Channel RTS CTS Flow Control C1 05 05 42 Active ST 5212 RS232 Communication 2Channel Cl OB OB 43 Active ST 5221 RS422 Communication Channel Cl 05 05 44 Active ST 5231 RS485 Communication Channel Cl 05 05 45 Active ST 5232 RS485 Communication 2Channel Cl OB OB 46 Active ST 5351 SSI Interface 1CH Cl 01 09 9E Active ST 5422 2 CH PWM output 1 5A 24Vdc source Cl 05 01 57 Active ST 5442 2 CH PWM output 0 5A 24Vdc source Cl 05 01 56 Active ST 5444 4 CH PWM output 0 5A 24Vdc source Cl OB 03 54 Active
24. ct ai 37 A PP E A 39 Copyright C CREVIS Co Ltd Support 82 31 273 6453 URL www crevis co kr CREVIS 5 FnIO PROFINET Adapter NA 9187 FnlO S Series 1 Important Notes Solid state equipment has operational characteristics differing from those of electromechanical equipment Safety Guidelines for the Application Installation and Maintenance of Solid State Controls describes some important differences between solid state equipment and hard wired electromechanical devices Because of this difference and also because of the wide variety of uses for solid state equipment all persons responsible for applying this equipment must satisfy themselves that each intended application of this equipment is acceptable In no event will CREVIS be responsible or liable for indirect or consequential damages resulting from the use or application of this equipment The examples and diagrams in this manual are included solely for illustrative purposes Because of the many variables and requirements associated with any particular installation CREVIS cannot assume responsibility or liability for actual use based on the examples and diagrams v If you don t follow the directions it could cause a personal injury damage to the equipment or explosion e Do not assemble the products and wire with power applied to the system Else it may cause an electric arc which can result into unexpected and potentially dangerous action by field devices Arching is explosion
25. er NA 9187 FnlO S Series 5 2 3 I O Process Image Map An expansion module may have 3 types of data as I O data configuration parameter and memory register The data exchange between network adapter and expansion modules is done via an I O process image data by FnBus protocol The following figure shows the data flow of process image between network adapter and expansion modules Network Adapter Expansion Modules Read Data Slot 1 Input Data Slot 2 Input Data Read A Slot 1 Slot 2 Slot 32 Network READ Write Data Write Network WRITE Slot 1 Output Data Slot 2 Output Data Slot 32 Output Data Copyright C CREVIS Co Ltd Support 82 31 273 6453 URL www crevis co kr CREVIS 21 FnIO PROFINET Adapter NA 9187 FnlO S Series 5 3 Example Configuration with SEIMENS PLC STEP7 5 3 1 Example GSDML Setting Copy GSDML files GSDML V2 0 Crevis NA9187 yyyymmdd xml and bitmap file and GSDML_002A_NA_NA9187 bmp to your hard drive in the same directory yyyymmdd year month day Start STEP 7 HW Configuration and install the GSDML file Options gt Install GSD File Select option for install GSD files as from the directory Caution The bit map file must be in the same folder as the GSDML file Install GSD Files Install GSD Files from the directory y DWFNIOWNASTSTANASTET GSDML FileWRew1_00 nglis English English English English English DO English
26. is co kr 34 6 2 3 Sub slot of NA 9187 FnIO PROFINET Adapter NA 9187 FnlO S Series Item Value Sub slot Number Sub slot Label 32768 0x8000 X1 32769 0x8001 X1 P1 32770 0x8002 X1 P2 Sub module Sub module Ident Number 0x00000007 NA 9187 Parameters Index 1 Length 2 Bytes Transfer sequence 0 Byte Offset Data 0 0x00 0x00 Name of Data Byte Bit Bit Value oo Parameter Type Offset Offset Length Details Range Changeable Visible woes Pu 0 0 1 MOTOROLA 0 1 Yes Yes format Area Stop action Pi 1 0 2 Clear ide 0 2 Yes Yes Area images to 0 ee a 1 2 2 Auto Reset 0 3 Yes Yes Interface NA 9187 Sub module Ident Number 0x0001 Sub slot Number 32768 0x8000 Supports Real time Class Class 1 Supports Isochronous Mode No AR Block Version 1 IOCR Block Version 1 Alarm CR Block Version 1 Sub module Data Block Version 1 Number of Additional Input CRs 0 Number of Additional Output CRs 0 Number of Additional Multicast Provider CRs 0 Number of Multicast Consumer CRs 0 Supported Send clock Factors Base 31 25us S ee 128 Supported Reduction Ratios 1 2 4 8 16 32 64 128 256 512 Port 1 Port 1 Sub module Ident Number 0x0003 Sub slot Number 32769 0x8001 MAU Type 100BASETXFD Port 2 Port 2 Sub module Ident Number 0x0004 Sub slot Number 32769 0x8002 MAU Type 100BASETXFD Copyright C CREVIS Co Ltd Support 82 31
27. n a hazardous environment which may lead to personal injury or death property damage or economic loss Identifies information that is critical for successful application and understanding of the IMPORTAN Product ATTENTION Identifies information about practices or circumstances that can lead to personal injury property damage or economic loss Attentions help you to identity a hazard avoid a hazard and recognize the consequences 1 1 2 Safety Notes DANGER The modules are equipped with electronic components that may be destroyed by electrostatic A 1 1 3 Certification c UL us UL Listed Industrial Control Equipment certified for U S and Canada See UL File E235505 discharge When handling the modules ensure that the environment persons workplace and packing is well grounded Avoid touching conductive components e g FnBUS Pin CE Certificate EN 61000 6 2 Industrial Immunity EN 61000 6 4 Industrial Emissions FCC Copyright C CREVIS Co Ltd Support 82 31 273 6453 URL www crevis co kr CREVIS FnIO PROFINET Adapter NA 9187 FnlO S Series 2 Specification 2 1 The Interface 2 1 1 NA 9187 ARA System Power 5Vdc PSSS System Power GND a FnBus Signal Portt y Field port2 CREVIS Device Name NA9187 xx Field Power 0Vdc gt Field Power 24Vdc OV 24V Field Power 24V OV System Power Copyright C CREVIS Co Ltd Support 82 31 273 6453 UR
28. n with Master oe NE es p pe erate a communication cable Check status in soft for Mast NET LED flashed green Failure of exchanging data with master ik u Ae configuration Check BUS line cable for connection ae with master NET LED is red Communication connecting lost Check duplication address Copyright C CREVIS Co Ltd Support 82 31 273 6453 URL www crevis co kr CREVIS 36 FnIO PROFINET Adapter NA 9187 FnlO S Series 7 2 How to diagnose when device couldn t communicate network Inspection of wrong or omission cable connection Check status of cable connection for each node Check that all color matches between connector and cable Check wire omission Terminator resistor If terminator resistor is not installed install terminator resistor Check location of terminator resistor Configuration of Node address Check duplication node address Configuration of Master Check configuration of master Check whether to do download or don t Check composition is right Configuration of communication baud rate VO size Configuration of each node Ground and environment Check ground is contacted Check environment factor temperature humidity etc is in less than regular limit Copyright C CREVIS Co Ltd Support 82 31 273 6453 URL www crevis co kr CREVIS 37 FnIO PROFINET Adapter NA 9187
29. re supported a variety of input and output field devices There are digital and analog input output modules and special function modules e Two types of FnBus Message Service Messaging I O Messaging FnBus Pin Description No Name Description 1 Vec System supply voltage 5V dc 2 GND System Ground 3 Token Output Token output port of Processor module 4 Serial Output Transmitter output port of Processor module 5 Serial Input Receiver input port of Processor module 6 Reserved Reserved for bypass Token 7 Field GND Field Ground 8 Field Vcc Field supply voltage 24Vdc Copyright C CREVIS Co Ltd Support 82 31 273 6453 URL www crevis co kr CREVIS 17 FnIO PROFINET Adapter NA 9187 FnlO S Series 5 2 PROFINET Electrical Interface 5 2 1 NA 9187 Signal PEPE RJ 45 Name Description Fl 1 TD Transmit 2 TD Transmit 3 RD Receive 4 5 6 RD Receive 7 Shielded RJ 45 Socket 8 Case Shield Y Cable EtherNet Cable Up to 100m from Ethernet Hub Upto 100m Upto 100m e FnIO FnIO Hub X Caution Industrial HUB for EIP recommended Cable the noise cable recommended ATTENTION The use of an incorrect supply voltage or frequency can cause severe damage to the component Copyright C CREVIS Co Ltd Support 82 31 273 6453 URL www crevis co kr CREVIS 18 FnIO PROFINET Adapter NA 9187 FnlO S Series 5 2 2 PRO
30. risk in hazardous locations Be sure that the area is non hazardous or remove system power appropriately before assembling or wiring the modules e Do not touch any terminal blocks or IO modules when system is running Else it may cause the unit to an electric shock or malfunction Keep away from the strange metallic materials not related to the unit and wiring works should be controlled by the electric expert engineer Else it may cause the unit to a fire electric shock or malfunction Y If you disobey the instructions there may be possibility of personal injury damage to equipment or explosion Please follow below Instructions O Check the rated voltage and terminal array before wiring Avoid the circumstances over 50 C of temperature Avoid placing it directly in the sunlight Avoid the place under circumstances over 85 of humidity Do not place Modules near by the inflammable material Else it may cause a fire Do not permit any vibration approaching it directly Go through module specification carefully ensure inputs output connections are made with the specifications Use standard cables for wiring e Use Product under pollution degree 2 environment Copyright C CREVIS Co Ltd Support 82 31 273 6453 URL www crevis co kr CREVIS 6 FnIO PROFINET Adapter NA 9187 FnlO S Series 1 1 Safety Instruction 1 1 1 Symbols DANGER Identifies information about practices or circumstances that can cause an explosion i
31. roperties for port 1 or port 2 Properties NA9187 Port 1 X1 P1 General Addresses Topology Options Port Interconnection Local port SIMATIC 300 Station NA SIE POr TPD S Medium Local port Copper Partnerport Cable name Copper A Partners Partner port Any partner y Alternating partner ports Cable Data Cancel Help Port Interconnection read only You can see the name of the local port Copper cable will be displayed as a medium for the local and partner port Partners The NA 9187 devices can support topology configuration You can interconnect NA 9187 devices under Partner port when one of below conditions are meet The port is connected to the PROFINET subnet Other PROFINET devices are connected to a port on the subnet The devices support topology configuration NA 9187 supports this functionality Select the required partner port from the Partner port drop down list The default setting is Any partner We recommended the default setting in normal case Copyright C CREVIS Co Ltd Support 82 31 273 6453 URL www crevis co kr CREVIS 31 FnIO PROFINET Adapter NA 9187 FnlO S Series e Port 1 or Port 2 Options Tab Properties NA9187 Port 1 X1 P1 General Addresses Topology Options Connection Transmission medium duplex Automatic settings Automatic settings LTP ITP 100 Mbp r Boundaries Cancel Help Transmission medium duplex
32. the NA 9187 at startup Ifthe Assign IP address via IO Controller check box is selected then the NA 9187 device receives its IP address at startup of the IO controller as described above To change this IP address click the Ethernet button If the Assign IP address via IO Controller check box is not selected then NA 9187 device has to get its IP address from its nov volatile memory than the IO controller If you want to change the IP address in non volatile memory please refer to Chapter3 Editing Ethernet Nodes Copyright C CREVIS Co Ltd Support 82 31 273 6453 URL www crevis co kr CREVIS 25 FnIO PROFINET Adapter NA 9187 FnlO S Series 5 3 3 Example Editing Ethernet Nodes in non volatile memory You can change the device name and IP address in non volatile memory To do this select the PLC Ethernet Edit Ethernet node menu command which starts the dialog below Please check below condition You must set PG PC interface to Ethernet card on your PC The NA 9187 devices must be in the same Ethernet subnet as the PG Edit Ethernet Node Ethernet node MAC address Nodes accessible online Set IP configuration Use IP parameters Gateway IP address Donotusarouter Subnet mask C Use router C Obtain IP address from a DHCP server Identified by Cc pE a Client ID D F easly IP Coniigarados Assign device name Device name Reset to factory settings
33. ust first assign the device a device name STEP 4 Click the Assign IP Configuration button Copyright C CREVIS Co Ltd Support 82 31 273 6453 URL www crevis co kr CREVIS 27 FnIO PROFINET Adapter NA 9187 FnlO S Series O Assigning Device Names If you configure a NA 1987 as a PROFINET IO device you can assign the PROFINET IO device name here The device name must be specified according to DNS conventions in other words Restricted to a total of 240 characters letters digits dash or period Restrictions regarding parts of the name within the device name in other words a string between two periods must not exceed a maximum of 63 characters No special characters such as umlauts etc brackets underscore slash blank etc The dash is the only permitted special character wow The device name must not begin or end with the character The device name must not have the structure n n n n n 0 999 The device name must not begin with the string port xyz x y z 0 9 The device name must be unique in the Ethernet subnet PROFINET IO system Click the Assign Name button to transfer the device name to the device O Reset to Factory settings With the Reset button you can reset the NA 9187 to the factory settings The IP address is then deleted IP address in non volatile memory will be 0 0 0 0 Device name in non volatile memory will be NULL