image

Contents

1. SeeEyes ELEVATOR FLOOR INDICATOR SC EFIO2 User s Manual a SE UA us ee tania di SC EFIO2 Severe Te Das PRTV DS 3 WAR Oe ge 4 gi m TEE ALINDING NSTA LULS 7 ed Sa fa as en a a ga a aes i me a a Sy a ee ay aa a a a a a eee el ee ee G VA SeeEyes Co Ltd Precaution and Safety Guidelines Please read this user s manual thoroughly prior to use the unit for Its easy and convenient use Do not install the product in the following places temperature conditions under 0 C or over 50 C places exposed to rain snow or high humidity places containing or exposed to oil and gas places exposed to vibration and Shock places under direct sunlight or exposed to outdoor weather conditions places exposed to radio waves RF or near to power lines It may cause low performance or malfunction of the unit Reproduction of this instruction or any part thereof without permission is strictly prohibited Do not use and or connect any devices inappropriate to the unit It may cause malfunction of the unit or fire Should you have any part of them not understandable or if you have any problem during your installation or in using it please contact us Please understand that the contents of this operating instruction may differ Slightly due to functional improvement of a product and based on the specification chosen by the user You can use this product easier and more conveniently if you use the function of
2. unit It may be subject to fire or electric shock If any smoke or smell is produced please turn off the unit and remove the power cable immediately and contact your distributor to check the device properly If the device does not work properly please contact your distributor 1 Introduction 1 1 1 2 Overview Using the SC EFIO2 Elevator Level Indicator you can display the real time lift location together with the video from CCTV camera As it is possible to record the video together with floor level to a DVR you can trace getting on off movement of suspects at the elevator As the sensor at main unit communicates with the reflectors at each floor individually it does not intercept the data at the lift and so there will be no argument with the lift maintenance company Features e Indication of the elevator floor level Possible to display the elevator location as OSD On Screen Display number on the monitor for CCTV camera installed at the elevator e Tracing the getting on off movement of suspects at the recorded video in a DVR e Real time monitoring of the lift movement e Possible to set the angle of the camera to display the face of the persons in the elevator e Easy installation on the top of the elevator and sharing the power with the camera no need extra power for the SC EFIO2 As it is possible to use the camera power it does not need to install extra power cable for the sensor and the main unit And it can easily inst
3. all at the back side of the camera with the harness cable provided e Six positioning of OSD off selectable You can select the position of the floor indicator as below upper middle lower middle e Provided with reflectors and silicon glue to easily adhere on the wall e Possible to indicate from the 99 levels above ground to the 9 underground levels B9 99 e Example 2 Components 2 1 Components E Bracket for Main Silicon Glue User s Main Units Reflectors Unit _ Manual 14 pes 1 pe e Binding bolt ar sensor bracket iron screw and ne washer x Installation accessories such as spring washers screw and others are included in the package as well If you need more reflectors for more than 15 stories buildings please contact us or your distributor for the availability 2 2 Bracket for the Main Unit To put the main unit on the top of an elevator you should use the mounting bracket There are two types of mounting brackets the standard bracket with 3 cm height included in the package and the tall bracket with 15 cm height sold separately upon request Depending on the installation condition you can choose the bracket you need Standard x The tall bracket is needed if the surface of the wall on which you want to adhere the reflector is not even If the surface of the wall is not even it is difficult to install the main unit on the top of the elevator and put the reflector at the right position on th
4. care such as Breakage or trouble made by natural disaster Breakage or trouble made by breaking the product guide or manual Breakage or trouble made by wrong power voltage or frequency When you want to reassemble for full system or replace parts within warranty service period When unauthorized person modified or made damage on the product trying to repair it Please note that we don t support the breakage after warranty service period is expired If the customer wants to get it repaired we charge them with the fee The specification is subject to change without prior notice for quality improvement AGN SeeEyes Co Ltd is the New Corporate Name of Samsung CCTV Service Co Ltd AGN SeeEyes Co Ltd 502 506 Sunil Technopia 440 Sangdaewon Dong Jungwon Gu Sungnam Si Gyeonggi Do Korea TEL 82 0 31 777 3508 FAX 82 0 31 777 3512 EMAIL overseas sscctv com http www sscctv com eng
5. de of the c bracket The I bracket can be mounted or not depending on the actual field e Put the main unit mounted at the bracket at the place selected using the steel screw To prevent the screw not to come loose due to the vibration produced for the operation of the elevator while you install the elevator floor indicator please use the spring washer provided with the unit Main Unit Installation Installation of Bracket The staff working inside of the elevator should stop the elevator at every floor and the elevator should be in automatic mode When stopping at each floor the elevator should be stop till the reflector is adhered on the wall 6 Move the elevator to the top or bottom floor to prepare fixing the reflectors 7 One person on the top of the elevator should fix the reflector and the other Should assist him her When you start from the bottom floor the lowest floor level press the button of the main unit at the lowest floor level and the laser pointer will light the position you should fix the reflector at the wall Then please fix the reflector at the laser pointer indicated position as below picture The assistant Should spread the glue on the back side of the reflector between the double sided tape to help the installer to adhere the reflector properly on the wall 10 e Standard Reflector Standard Reflector 6 W X 9 5 H e The hole of the reflector and the laser point s
6. e wall If you put the main unit 15 cm up you will be able to adjust the position of the reflector more easily 3 Product Parts and Installation 3 1 Name of the Parts and Function Elevator Floor Indicator SC EFIO2 q LASER ON OFF SWITCH OSD POSITIONING SWITCH d DED H208 40 o P A URE TEM BH BOI FASES Essie Alo LD AND HAPE XE 45 70cm A 2 ENE So seo dz a HUZE HBS HR DE NIE AC MBBS DCE Been 4 LASER AST SA Qua ao 5 EH DEPE yous aoe UE 6 12 26304 LASER HE Ate SE BH 240 ENE MEC eit TERRE 7 FESS EEN ESS BAe at IESE JEEYAN 180 Baa Bou Pao Pat aS NaBH B 2 PA DO Se ROS Sue SAS BUSA EE VESPA Mo THAI S08 SUS Sess OVA MOI q BSS iso ef Beco ABES 031 777 3507 q DC F amp BNC Harness 3M DC 12V Power Output cameras amp Input from the video camera q Video output for monitor or DVA q Dc 12v IN Front LASER OUT It indicates the right position to place the reflectors on the wall Please read the safety guidelines at page 1 prior to install the units 2 Sensors Laser sensors 4 LASER ON OFF BUTTON Press this button to turn on off the laser Please read the precaution notes prior to use the button OSD Position Setting Button You can change the position of the characters indicating the floor displayed on the screen 6 RS 232C Port for the OSD Setting 6 1 How to set the OSD menu Use this menu only when you should change the OSD e First connect the SC EFIO2 t
7. hould be located as below Good Good Warning If the laser point is located lower than reflector s hole the elevator floor indicator may not operate correctly e The reflector for the base floor 11 Base floor reflector 6 W X 19 H e How to adhere the reflector Spread the glue in the middle of the back of the reflector as indicated the figure Put the glue sufficiently and let the glue be spread when you attach the reflector Remove the protective film of to the wall the double sided tape Back side of the Reflector Stop at each floor and fix the reflector at the wall at the same way as indicated above For the base floor please make sure to use the 19 cm height reflector for the base ground floor only After the installation of all the reflectors is completed at each floor set the elevator in manual mode and immobilize the elevator a Then connect the main unit with the camera installed at inside of elevator as illustrated at the connection diagram menu 4 1 2 To supply the power to the unit please connect 12VDC adaptor for the camera to the main unit and then connect DC jack at the main unit to the camera In case the camera is for AC power please use additional 12VDC adaptor for the main unit 12 13 Place and connect the cable of the main unit properly at the top of elevator Please refer to the installation diagram menu 4 2 After the installation is completed select the OSD positio
8. n using the OSD positioning switch at the main unit And then please check whether the number or character indicating the floor level is displayed correctly in the picture from the place where your DVR is installed or you can use our portable test monitor SC LFC56L to check as well 5 Specification MODEL SC EFIO2 CVBS 1 0Vp p 75Q Term DC Jack DC 12V over 500mA Max Output lt 5mW LASER RADIATION WAVELENGTH 650nm 10 CLASS Ill A Laser Video Input DC F amp BNC M Harness Cable 300Cm Connect Video Output BNC F Pon DC JACK Tact Switch MODEL Reflector 6 W X 19 H one 1 piece provided Other Floors 6 W X 9 5 H 14 pieces provided 13 6 Warranty Certificate This product has passed thorough quality control and test and if this gets broken during normal use we provide 12 months warranty service Model No Serial No Distributor Date you purchased Place you purchased Warranty Period One 1 year from the date of purchase eee e Please check this warranty indication first e Please contact your distributor after checking out any defect in the products e The standard for repairing replacement or reimbursement follows Customer e Warranty content any defect under normal use within the warranty service period we give you free repair service according to the warranty certificate We charge you with the fee of parts and service despite of free warranty service period Any breakage made without
9. o a PC or laptop using the RS 232C port eThen install a serial communication program to the PC using the hiperterminal of the Windows Select the serial port you want to connect the communication program COM1 COM2 COM3 Baud Rate Parity Flow control 115200 bps Baud rate Data Parity Stop Flow control Transmit delay 0 msec char 0 msecjline e If you turn on the SC EFIO2 after connecting the unit to the PC using the RS 232 serial cable it is displayed the following menu at the window eS COM3 115200bDaud Tera Term VT File Edit Setup Control Window Help ss SC EFIO2 Floor Display OSD Setup Reset Cursor 22 22 32 32 Floor Characters or numbers indicating the floor level e Select and change the characters or numbers by moving the curser using the direction keys on the computer s keyboard e You can use O 9 AnwZ e RST It indicates the base floor level Select from 9 to 99 floor level x What is a base floor The SC EFIO2 has a separate sensing structure in order not to interrupt the operation of the elevator by its sensor So you should install the reflector for the base floor the reflector with 19cm to reset any possible error be produced during its operation Selection of the base floor It is recommended to select as a base floor level the floor where most of the people get on off such as the ground level or level 1 Installation
10. of the reflector for the base floor Put the 19cm reflector for the base floor The 14 pieces of normal reflector should be use for other floors VIDEO IN amp DC 12V OUT Connect with video output connector BNC M and power input DC jack of the camera VIDEO OUT Connect with coaxial cable for DVR or Monitor DC 12V IN Connect with the power adaptor for camera 4 Installation 4 1 Connection Diagram SC EFIO2 CAMERA ADAPTER e Connect a power adapter 12VDC over 0 5A to the SC EFIO2 and supply the power of the camera through the harness cable of the SC EFIO2 4 2 Installation Diagram Should be separated min 50Cm 7 H jo T H SRS aaa ada prensada MORRER atetetetsts gtetetetets 7 E 4 te Reflector Elevator SC EFIOZ DOME CAMERA Not Wall e The reflectors on the wall should be separated from the SC EFIO2 max 1m and min 50cm away 5 How to install Please read this user s manual thoroughly prior to install the unit 5 1 Installation Order To attach the bracket for SC EFIO2 main unit onto the top of the elevator please stop the elevator at the proper position where you can easily approach to the top of the elevator 2 It needs three personnels to install the unit at the elevator properly Two persons should be on the top of the outside of the elevator and one person Should be place at the inside of elevator 3 Select the most proper position for
11. the installation of the main unit Please be careful when selecting the place you want to install the main unit of SC EFIO2 The SC EFIO2 and any facilities or equipments installed on the wall should not mutually interrupt each other s operation while the elevator is running Please refer to the illustration below For example select a least three 3 places where can be proper for the installation of the main unit and then move the elevator from the lowest level to the highest level so as to check whether there is any obstruction or not and then choose the most easy and proper place to install the unit It is very important to find the most appropriate place for the main unit First of all there should not be any mutual interruption between the SC EFIO2 and other equipments installed Second the operation of the sensor should be not interrupted while the elevator is moving Third the distance between the elevator and the wall should be over 50cm And it is also important to find the most proper place where the main unit can be mounted with the steel mountable rack on the elevator 4 Mount the main unit using the bracket e Mount the main unit s bracket designed like c at the lower right and lower left side using the screws provided in the package The location of the right and left of the bracket can be varied depending on the installation conditions e Mount the I bracket at the lower side of the main unit at the opposite si
12. the product only after reading this operating instruction carefully When you need to change the character of the Elevator Floor Indicator or to change the standard floor or to skip some floor not used please refer to this user s manual or contact us Please note that this product is working independently using its own sensor not to interrupt the elevator s functions or make interference or damage to any facilities installed in the elevator Please make sure that the laser beam should be off position after finish the installation of reflectors Please do not attach any other devices to SC EFIO2 For emergency please announce the installation status to the control room watching center prior to the installation job Installers should be aware of the safety equipage such as helmet prior to the installation for their own safety At least two or more installers are required to install SC EFIO2 and please contact the elevator maintenance company prior to the installation for their any assistance Please avoid laser radiation direct exposure to eyes It may damage your eyes Please use protector cable such as herical band to the sensor and the harness cable of the main unit in order to cut the cable or produce short circuit Should use only 12VDC power adaptor Or it may damage the unit Do not subject the product to physical shock or exert excessive force to operate the product Do not use the device when any smoke or smell is produced from the

Download Pdf Manuals

image

Related Search

Related Contents

USER`S MANUAL  scolaires - Académie de Versailles  AD-4402 OP-22 取扱説明書  1.7MB - 三陽機器  Samsung WA1150S User Manual  dichiarazione ce di conformitá per macchine avvertenze per l  ICD200 シリーズ 【取扱説明書】  ポポラ ローマンシェード シングルシェード コード式 取扱説明書  2台パソコンを接続、データ転送  ANSI/AAMI EC13:2002, Cardiac monitors, heart rate meters, and  

Copyright © All rights reserved.
Failed to retrieve file