Home

AC Bank 说明书(USA)

image

Contents

1. Battery Connect with the battery 13 Battery Connect with the battery Note Allowing for additional battery storage in parallel with battery inside cabinet Note The SAP W 600 and SAP W 1000 units feature both solar charging and AC grid charging capabilities When the solar and AC inputs are connected they will both charge the battery when the battery voltage is below 11 5V This combined charge will continue till the batteries are fully charged at 13 7V Ifthe battery voltage is above 11 5V only the solar panels will be charging the system except in initial use 07 3 2 Connecting an External Battery to the AC bank Additional battery storage capacity can be added to the Powerbank utilizing the parallel connections provided Built in Battery External Battery BATTERY Please note the charging performance of the system will be affected when adding additional battery capacity It will take the system longer to fully charge the batteries The type and nominal voltage of the external battery has to be same as the battery inside the powerbank but battery capacity can be different When adding a battery please follow the steps below Turn off the BREAKER Securely connect the positive and negative battery terminals to the corresponding terminals on the Powerbank Incorrect connection can cause system damage Make sure all connections are secure and tight Loose connect
2. 12 Solar panel Connect with PV 13 Battery Connect with the battery 14 Battery Connect with the battery Note Allowing for additional battery storage in parallel with battery inside cabinet 06 B SAP W 600 No Name Function 1 LCD display Display the status of system 2 DC 12V output Li L2 L3 L4 Connect with 12V DC load 3 USB 5V output Connect with 5V DC load 4 120V AC output Connect with 120V AC load 5 Grid input Connect with grid Power 6 Switch Inverter switch 7 Green LED Inverter work indicator 8 Red LED Inverter failure indicator 9 Breaker General power switch 10 Solar panel Connect with PV 11 Solar panel Connect with PV 12 Battery Connect with the battery 13 Battery Connect with the battery Note Allowing for additional battery storage in parallel with battery inside cabinet C SAP W 1000 Name z 2 Function LCD display Display the status of system DC 12V Output L1 L2 L3 L4 Connect with 12V DC load USB 5V output Connect with 5V DC load 120V AC output Grid input Connect with 120V AC load Connect with grid Power Switch Inverter switch Green LED Inverter work indicator Red LED Inverter failure indicator OLOINIDIOIR WIN eR Breaker General power switch Connect with PV Solar panel Connect with PV Solar panel 11
3. Indicates a system failure has occured Indicates battery state of charge Indicates the unit is connected to the grid AC power and is charging the batteries A DANGER Never connect grid input Part No 5 on Page 07 to AC output Part No 4 on Page 07 it will cause irreparable damage to the inverter gt i XO amp 11 B Adjusting System Parameters Interface Button use this to switch between the various charging parameters Figure 1 Use this button the adjust the parameter up W Use this button the adjust the parameter down To reset to factory default press and hold the button for more than 5 seconds wr FF WA 127 Main interface HVD LOAD ON LOAD OFF LOAD ON 24 aiel T oal 126 o Load mode LVD LVR Low Voltage Reconnection Figure 1 C LCD Screen Explanations View amp set system parameters he Display on left shows solar panels are connected load is i28 4 connected battery status battery voltage and AC output voltage 9 eu Y This function switches the load On Off e View and set the High Voltage Disconnect p gt ty The value for the HVD High Voltage Disconnect is shown When 13 l this is achieved the controller will disconnect the charge to prevent over charging battery This parameter can be adjusted up or down Press Y and the number will flash Use the amp to adjust the parameter up or down then press the
4. can offer stable and reliable electricity to those regions that are short of power or even without power 1 1 Features e Compact portable and convenient Quick and easy installation e Simple design adapt the system to meet your requirements e LCD display clearly shows system status at all times e Reliable maintenance free performance e Power generation and storage for uninterrupted use in places without electricity e Various applications ranging from everyday to emergency power supply 1 2 Technical data Component Parameters SAP W 300 SAP W 600 SAP W 1000 Type NO Qty SLP100 12 1pc SLP100 12 1 2pcs SLP100 12 2 4pcs Peak Power Pm 100W 100W 100W Open Circuit Voltage Voc 21 6V 21 6V 21 6V Solar Panel Max Power Voltage Vmp 17 2V 17 2V 17 2V Short Circuit Current Isc 6 46A 6 46A 6 46A Max Power Current Imp 5 81A 5 81A 5 81A Cable 2x1 5 mm x 5m 2x1 5mm2 x 5m 2x1 5mm2 x 5m Nominal Capacity 55Ah 100Ah 200Ah Battery Nominal Voltage 12V 12V 12V Max Outer Dimensions LxWxH 275x175x235mm 440x235x280mm 530x285x285mm Model Type NO SPB AW 55 300 SPB AW 100 600 SPB AW 200 1000 Rate Voltage 12V Max PV Charging Current 10A 30A 30A Powerbank DE Max PV Input Voltage lt 25V Controller High Voltage 144 0 2V 13 7 0 2V Disconnection Low Voltage Disconnection 10 5 0 2V 10 740 2V Low Voltage Reconnection 11 54 0 2V 12 640 2V 01 Componen
5. the inverter functioning within 10 seconds The protection indicator light will indicate the system overload state Power down the system by turning the power breaker switch to the OFF position and disconnect the loads After 10 15 seconds switch the Powerbank back ON and start connecting the loads being careful not to overload the unit Short Circuit Protection When a short circuit occurs the inverter stops functioning immediately The protection indicator light will indicate the short circuit has occured You must identify the source of the short circuit and resolve the issue Power down the system by turning the power breaker switch to the OFF position After 10 15 seconds switch the Powerbank back ON e High Temperature Protection When the inverter temperature reaches 75C it stops functioning immediately The protection indicator light and alarm will indicate the temperature is a problem Power down the system by turning the power breaker switch to the OFF position Allow the system to cool down and we recommend you look for a better ventilated location to place the unit to avoid future overheating After sufficient cooling switch the Powerbank back ON 09 3 4 Setting Up the Powerbank Please carefully read the following safety precautions and related operation instructions before commencing installation and set up e Ensure the intended location meets the requirements set out in section 2 3 of this document e Ensure the power brea
6. E for 5 seconds till the number stops flashing Press W again to go to the next parameter 12 View and set the Low Voltage Reconnect LOAD ON cb The value for the LVR Low Voltage Reconnect is shown This parameter can be adjusted up or down Press Y and the number will flash Use the to adjust the parameter up or down then press the E for 5 seconds till the number stops flashing Press ff again to go to the next parameter e View and set the Low Voltage Disconnect LOAD OFF The value for the LVD Low Voltage Disconnect is shown When this is achieved the controller will disconnect the load to prevent over discharging battery This parameter can be adjusted up or down Press and the number will flash Use the to adjust the parameter up or down then press the amp for 5 seconds till the number stops flashing Press again to go to the next parameter e View and set the Load Working Mode LOAD ON en g F 24h Indicates Normal Mode The bank has continual DC power output 1h 23h means Light Control and Time Control Mode the bank has DC power output after dark and then cut off the DC power output according to the timer setting Oh Means Light Control Mode the bank has DC power output after dark and then cut off the DC power output after dawn In this interface you can use the button W A to adjust the parameter
7. Solar Powerbank W Series USER MANUAL amp PRODUCT SPECIFICATIONS Models SPB AW 55 300 SPB AW 100 600 SPB AW 200 1000 S LARLAND Solar Technology and Solutions Thank you for choosing the Solarland Solar Powerbank Please read this manual carefully before setting up and using the product Pay close attention to all instructions and keep this user manual for future reference Content 1 Product Introduction 01 1 1 Features 01 1 2 Technical Data 01 1 3 Storage and Working Environment 02 1 4 Application 02 2 Installation Instructions 03 2 1 Kit Components All sold Separately 03 2 2 Solar Panel Installation 03 2 3 Powerbank Installation 05 2 4 Connecting the System 05 3 Powerbank Control Panel amp Connections 06 3 1 Schematic Drawings amp Powerbank Layout Explanation 06 3 2 Connecting an External Battery to the AC bank 08 3 3 Performance 09 3 4 Setting Up the Powerbank 10 3 5 LCD Display Explanation 11 3 6 Common Faults amp Fixes 12 4 FAQ amp Trouble Shooting Guide 15 5 Warranty 17 1 Product Introduction Since 2003 Solarland has been developing designing and manufacturing off grid solar systems bringing power to structures and villages all over the world where no electrical power grid exists The Solar Powerbank is the latest innovation in this series of power products Simplified structure reliable performance easy operation It
8. The number will be flash After long press the key E gt 5seconds the number will be saved and stop flash Short press E to give up save the number and exit to next interface 13 3 6 Common Faults amp Fixes Error Code E04 Low Voltage Protection BATTERY N D5 EGY x Oo The LVD protection has been activated and the load circuit has been disconnected by the controller The batteries require to be charged and the system will resume normal operation when the LVR voltage has been attained Error Code E02 Overload Protection 128 E0 x The screen will display as shown The system load has exceeded the controller has entered the system parameter Turn the unit off remove loads Add loads carefully to not overload the system again and press the button to restore power to the load Error Code E01 Short Circuit Protection ps m ut x The screen will display as shown This indicates a short circuit on the load loop circuit Check the load s for damage after trouble shooting and clearing the problem press the button to restart the system 14 4 FAQ amp Trouble Shooting Guide Problem Possible Reason Corrective Action LCD Display Not Working LCD Displays but no DC Output No fault displayed on LCD Circuit Breaker Switch in OFF position Set Circuit Breaker to the ON position Battery is connecte
9. d in reverse Turn Powerbank OFF disconnect and reconnect the battery correctly Note the reverse connection of the battery may have damaged the inverter Battery is deteriorated and voltage is below 9V Check battery condition and try recharge If they do not hold the charge they should be replaced with new batteries The LCD wire conncetions are loose or have come away from the meter during transportation The solar controller wire conncetions are loose or have come away from the meter during transportation DC Output is not turned ON Poor connections on the solar controller particularly check the load output connection Turn the Powerbank off and reconnect the wires to the LCD meter Turn the Powerbank off and reconnect the wires to the solar controller Press the button below the LCD screen to turn the DC Output ON Turn Powerbank OFF and reconnect all solar controller connections No AC Output Inverter switch is not in the ON position Press Switch to the ON position Inverter Switch is damaged Turn Powerbank OFF and replace Switch Inverter is damaged Turn Powerbank OFF and replace Inverter Poor connections on the solar controller particularly check the load output connection Turn Powerbank OFF and reconnect all solar controller connections Solar Panels connected but no Charging Status showing on the LCD Solar panels are not correctly posit
10. e The AC inverter has a high voltage output avoid contact at all times e This kit has been specifically designed to work with just the provided components The use of non standard components such as different panels can cause damage and void the warranty THE METAL HOUSING OF THE POWERBANK SHOULD BE PROPERLY GROUNDED AT ALL TIMES PLEASE CONSULT WITH A QUALIFIED ELECTRICIAN FOR GROUNDING ADVICE WARNING FAILURE TO GROUND OR IMPROPER GROUNDING MAY RESULT IN SERIOUS INJURY AND OR POSSIBLE DEATH 05 A sonce e Ensure all master power switch and breaker switch are in the off position before commencing with the connections Connection Order 1 Powerbank to Battery 2 Powerbank to Solar Panel s e Please DO NOT do withstanding voltage test to the Powerbank Irrepairable damages to the Powerbank and components will occur 3 Powerbank Control Panel amp Connections 3 1 Schematic Drawings amp Powerbank Layout Explanation A SAP W 300 No Name Function 1 Analog Voltmeter Display the voltage of the battery 2 DC 12V output Li L2 L3 L4 Connect with 12V DC load 3 USB 5V output Connect with 5V DC load 4 120V AC output Connect with 120V AC load 5 Switch Inverter switch 6 Green LED Inverter work indicator 7 Red LED Inverter failure indicator 8 Red LED Charging indicator 9 Green LED DC load indicator 10 Breaker General power switch 11 Solar panel Connect with PV
11. ioned Insufficient sunlight Ensure the panels are placed in full sunlight with no shadows or other obstructions In cloudy and rainy condistions the solar panels will generate a small charging current The Powerbank will not detect the current if it is below 0 1A Solar Panel connections are loose Check all connections and tighten where required Solar Panels connected in reverse Turn Powerbank OFF and reconnect the Solar Panels correctly 5VDC amp 12VDC Outputs only work at night Load mode of the controller has been reset to 0 23 Reset the load mode to 24 15 Problem LCD Displays E01 Fault Possible Reason Short circuit has occurred Corrective Action Turn Powerbank OFF amp check all components and cabling to clear any short circuit LCD Displays E02 Fault LCD Displays E04 Fault RED LED is ON no AC output DC Output overload has occurred Battery Voltage is LOW AC Output Overload has occurred AC Appliances peak power exceeds system limitations Battery input voltage is too high Turn Powerbank OFF amp remove all loads Turn the Powerbank ON and reconnect the loads careful not to overload again Turn Powerbank OFF amp remove all loads Turn the Powerbank ON and allow the battery to recharge before connecting any loads Turn Powerbank OFF amp remove all loads Turn the Powerbank ON and reconnect the loads careful not to over
12. ions will cause system performance issues and possible system damage The wires cables to the external battery should not exceed 1m 40 It is important to select the correct wire size to ensure the best possible system performance see chart below CABLE SAP W 300 6mm2 SAP W 600 12mm2 SAP W 1000 20mmz2 Turn on the BREAKER and the system should function properly with the additional battery capacity 08 3 3 Performance Battery Charging Function The Solarland Powerbanks utilize a state of the art Smart controller to ensure the most efficient battery charging The battery will not overcharge and the system has reverse polarity protection Low Voltage Disconnection Function LVD The Solarland Powerbanks utilize a long life inverter that automatically recognizes a battery with low voltage and will disconnect the DC loads to avoid permanent battery damage This disconnect occurs at 10 7 0 2V on models SPB AW 100 600 and SPB AW 200 1000 The disconnect occurs at 10 540 2V on model SPB AW 55 300 All models will disconnect the AC loads when 10 0 0 5V High Voltage Disconnection Function HVD The rated input voltage of the inverter is 12V If the input voltage of inverter is more than 16V the High Voltage Disconnection will occur automatically to protect the battery e Electronic Overload Protection When the total power draw exceeds the rated power of the inverter the overload protection will stop
13. ker switch is set to the OFF position Ensure the battery to be used meets the minimum battery voltage requirements Connect the red cable to the positive battery terminal and the black cable to the negative battery terminal Make sure all connections are tight and secure Note that connecting the battery incorrectly can cause a short circuit and system damage e Switch the power breaker switch to the ON position The LCD display will indicate the battery charge condition e Switch the inverter on and the indicator light should come on Connect the solar panels to the assigned positive and negative connections on the Powerbank If the panels are in sunlight the LCD will indicate the state of the solar charging A DANGER It is VERY IMPORTANT to follow the set up instructions exactly The breaker switch will automatically disconnect the system in the event of a major failure Do NOT disconnect the breaker switch when the system is working normally If you have to disconnect using the breaker switch be sure to disconnect the solar panels first When re setting the breaker switch make sure you reconnect the solar panels after the breaker switch has been reconnected 10 3 5 LCD Display Explanation LOAD PV ON OFF BATTERY AM PM B88 ro A LCD Displaying LCD Displaying have left side of parameters and right side of parameters Indicates Solar Panels are connected Indicates the load appliance is connected
14. load again Check the power draw of the appliances does not exceed the system limit Check each appliance power specification and ensure they do not exceed the inverter output Check battery voltage and ensure it does not exceed the maximum safety voltage of the inverter AC Load Power is low AC Starting Load is too big This is a normal situation and occurs when too many loads are attached at start up Disconnect the loads and add them in order from largest to smallest Alarm is sounding Battery discharges quickly Low Voltage Battery is discharged and has low voltage Turn Powerbank OFF and recharge the batteries till a full charge is achieved High Temperature the Powerbank has overheated AC load is too big resulting in rapid discharge Lifetime of battery is over Turn Powerbank OFF Remove loads and allow to cool Check location of the Powerbank is well ventilated Reduce the AC Load Add external battery to handle the extra power requirements To change a new battery 16 5 Warranty The Solarland AC Powerbank has a warranty of 1 year from date of invoice Please read these instructions very carefully The manufacturer shall not be liable for damages to the system including the battery caused by misuse and or the user failing to follow the instructions as set out in this manual The manufacturer shall not be liable for damages caused by service or repair by an
15. st not be immersed in water either fresh or salt or constantly be exposed to water either fresh or salt i e from fountains sea spray Do not mark the back of modules with sharp materials Do not destroy modules tear down modules B Optional Solar Panel Mounts Wall mount Roof mount Note Panel mounts are not included in the kit and are optional add ons The kit shown above is the Solarland SLB 0103 Tilt Mount Kit 04 2 3 Powerbank Installation It is most important you follow these instructions properly otherwise damage and or injury can occur nonce e Place and operate the unit on a stable and level floor Do not spray or splash water directly onto the unit e Keep the unit away from direct sunlight Keep away from open flame and high temperatures Keep well ventilated Avoid placing near corrosive gases and or liquids e Place in a well ventilated cooler location e Do not insert objects and or liquids into the unit e It is advised that only a qualified professional open the box and perform maintenance 2 4 Connecting the System A DANGER In order to avoid electrocution and fire hazards pay attention to the following Before commencing installation make sure the switch on the Powerbank is OFF e It is advised that only a qualified professional install the system e Avoid contact with terminals and circuit boards e Be careful not to short circuit the terminals
16. t Parameters SAP W 300 SAP W 600 SAP W 1000 Max AC Charging Current N A 8A AC 5 z Charger Charging Starting Voltage N A 11 5 0 2V Charging Stopping Voltage N A 13 7 0 2V USB Max Output DC Voltage Current 5V 600mMA Output DC Outlet Max Output Current Voltage 1A One Route 12V Powerbank Max AC Output Power lt 300W lt 600W lt 1000W Output Wave Mode Modified Wave Pure Sine Wave Output Voltage Frequency AC 120V 10 60Hz 2Hz Inverter Self comsunption lt 1 5 Low Voltage Disconnection 10 0 0 5V 10 040 5V High Voltage Disconnection 15 5 0 5V Low Voltage Alarm 10 5 0 3V 10 5 0 3V Other Dimension LxWxH 300x180x550mm 460x240x550mm 560x290x480mm 1 3 Storage and Working environment A Storage e Place in a well ventilated area free from dust and debris Ideal Temperature Range for Safe Storage Inverter amp Battery 10 C 40 C Solar panel 40 C 90 C Avoid humid conditions and moisture such as condensation e Keep away from erosive gases and or liquids When storing for long periods it is important to completely charge and discharge the system at least once every 6 months B Working environment e Ideal Working Temperature Range Inverter amp Battery 10 C 40 C Solar panel 40 C 90 C e Moisture 0 90 Elevation lt 5000m Avoid humid conditions and moisture such as condensation 1 4 Application The Solarland Powerbank kits are scaled to meet many different power demands and can be
17. unauthorized person incorrect set up amp Installation or bad system design The warranty is immediately void if batch numbers serial numbers or identification marks are manipulated or are unidentifiable The warranty covers parts and components only The warranty does neither cover the cost of transportation for the return of the system or components nor for the additional shipment of replacement components The warranty does not cover the cost for installation or reinstallation of the system 17 Head Office 12Fl C Bldg 16 Changjiang Rd Wuxi 214028 Jiangsu P R China Tel 86 510 81191956 Fax 86 510 85203812 www solarland com info solarland com Version M1305U General Disclaimer In no event shall the manufacturer liable for may damage or personal injury caused by non compliance to the operating instructions and safety suggestions in this brochure The manufacturer will not bear any responsibility for misuse damage injury incorrect installation and or system design as such
18. used in many applications including households schools communications marine military rural electricity agriculture street lamps street stalls special events etc 02 2 Installation Instructions 2 1 Kit Components All sold Separately SAP W 300 SAP W 600 Component Type Qty Type Qty Powerbank Cabinet SPB AW 55 300 SPB AW 100 600 SPB AW 200 1000 Battery Recommend 55Ah 100Ah 200Ah Solar Panel SLP100 12 SLP100 12 SLP100 12 iset SLB 0103 1 2sets SLB 0103 SAP W 1000 2 4sets Solar Bracket Optional SLB 0103 Other User s Manual 2 2 Solar Panel Installation A Orientation amp Tilt The solar panels perform best when set up at 90 to the direct sunlight A sonce e Panels should be installed in a well ventilated location High temperatures will reduce the performance of module lowering power output The solar panels are water resistant but not waterproof DO NOT submerge in water or expose the panel to a continual flow of water 03 Do not install the panel in a location where the sunlight may be blocked from getting to the panel Do not install panels flush to the roof there must be a gap for ventilation Do not install the module or mounting system in high corrosion areas Do not drop or allow objects to fall onto module Do not drill holes in frame Do not install module Keep away from fire near flammable gases The module mu