Home

User`s Guide

image

Contents

1. mieu EE CO Go To Table Of Contents Important Information Safety Symbols a N DANGER Indicates an imminently hazardous situation which will result in serious or fatal injury if not avoided This symbol is used only in the most extreme conditions Jj N WARNING Indicates a hazardous situation which could result in serious injury if not avoided FK N CAUTION Indicates a potentially hazardous situation which could result in minor or moderate uL id 4 if not avoided It may also be used to alert against unsafe practices J E Equipment Alert Note Indicates a potentially hazardous Amplifies a procedure practice or condition situation which could result in equipment damage if not avoided Dangerous voltage shock hazard N Consult User Guide for important information Transportation Storage Conditions Ambient Temperature Range ssssse 5 C to 38 C 41 F to 100 F Relative Humidity see 10 to 90 non condensing Atmospheric Pressure sees 500hPa to 1060hPa 0 49atm to 1 05atm Intended Use This product is intended to be used as a table to provide positioning support and cleaning of animals during examination or minor surgery procedures conducted by qualified professionals Electrical Precautions Use nonconductive material to insulate patient from metal portions of table Con
2. 5 12 7 cm Max w o Pad 44 111 8 cm Max w Pad or 43 5 110 5 cm Max w o Pad xL 22 9cm 88 9 cm VA1700i 10 Go To Table Of Contents Warranty Information Limited Warranty SCOPE OF WARRANTY Midmark Corporation Midmark warrants to the original purchaser its new Animal Care products and components except for components not warranted under Exclusions manufactured by Midmark to be free from defects in material and workmanship under normal use and service Midmark s obligation under this warranty is limited to the repair or replacement at Midmark s option of the parts or the products the defects of which are reported to Midmark within the applicable warranty period and which upon examination by Midmark prove to be defective APPLICABLE WARRANTY PERIOD The applicable warranty period measured from the date of delivery to the original user shall be one 1 year for all warranted products and components EXCLUSIONS This warranty does not cover and Midmark shall not be liable for the following 1 repairs and replacements because of misuse abuse negligence alteration accident freight damage or tampering 2 products which are not installed used and properly cleaned as required in the Midmark Installation and or User s Manual for this applicable product 3 products considered to be of a consumable nature 4 accessories or parts not man
3. Go To Table Of Contents Canis Major Exam Lift Table For models CMWO without scale CMWS with scale User s Guide NNI 1 Style C Go To Table Of Contents Product Information The information below is required when calling for service Dealer name phone Model Serial Number P Model Serial Number Location 4 lt Date of Purchase Midmark Authorized Service Company name phone VA101700i Table of Contents Important Information Safety Symbols sigen i E iatis cte iD LA ES Transportation Storage Conditions sesssssssseeseeeeeeeene nnne Intended 8 Electrical Precautions uas cocaine eui E done Pod s Operation Table Up Down Hand Switches ssssssssseeeseseeeeeneneen nennen Table Up Down Foot Control esssssessseseseeeeen enne enne nennen scale Optional mU aE Maintenance M lernte Mr P n Preventative Maintenance eesesssssisseeseeeseeeenne enne nennen nennen nnne nnns nnns TOUDICSNOONN Os sssi EE Calling FOSC E er aaa et aL ee ces Specifications Weights Dimensions Electrical Specifications cceecceccceeeeeneeeeeeeeessteeeeeeeeeseaes Rango ol MONON oec E ettet n tote eint spit OM se ITE Warranty Information Limited Warranty E
4. surfaces may cause pitting corrosion or metal discoloration Preventive Maintenance Periodically inspect the following areas Power cord should be free of cuts or other visible damage All fasteners should be present and tightened securely All mechanical functions should operate properly Have an authorized service technician inspect your table on a regular basis o e HE Go To Table Of Contents Maintenance Troubleshooting If the table will not go up check the following Unit is plugged into a wall outlet Power to the outlet No visible damage to wiring The table is at its maximum height hand toggle switches If the table will not go down check the following Unit is plugged into a wall outlet Power to the outlet No visible damage to wiring The table is at its minimum height The safety pan switch is out of adjustment hand toggle switches e The safety pan bound or switch is out of adjustment If the scale does not operate check the following e Refer to scale section elsewhere in this manual Calling For Service Foot control is fully inserted and making proper connections try either Toggle switch is bad try using switch on other side or foot control The safety pan switch is activated by an obstacle beneath the table Foot control is fully inserted and making proper connections try either Toggle switch is bad try using switch on other side or foot control If the tab
5. ance Cleaning Tabletop Mat The tabletop mat should be cleaned between patients with a virucidal agent or mild disinfectant spray and towel or cloth dried The mat can be moved to a tub or sink for a more thorough cleaning Equipment Alert Silver nitrate and betadine can stain the mat Certain pharmaceutical products such as ADVANTAGE will react and cause bubbles on the mat surface Caution must be used when selecting a cleaning agent Painted Surfaces Clean the table weekly wiping the painted metal and plastic surfaces with a clean soft cloth and mild cleaners Periodic applications of common furniture wax will ease cleaning and maintain the finished luster of the table s painted surfaces Stainless Steel Surfaces For best results stainless steel should be cleaned weekly or whenever films or deposits become apparent Use a mild cleaning agent and whenever possible rinse thoroughly and towel dry More stubborn deposits or tightly adhering debris may require vigorous rubbing or brushing If a commercial cleaner needs to be used make sure it is approved for use on stainless steel surfaces Equipment Alert Always use nylon or plastic bristle scrubbers The use of steel wool or steel brushes may cause steel particles to become embedded in the surfaces and will cause rust Avoid prolonged surface exposure to chlorides bromides iodides and thiocyanates Salty solutions allowed to evaporate on stainless steel
6. le won t stop when encountering an obstacle beneath the table check Note Model Serial Number information is required when calling for service If service is required contact your Midmark dealer To contact Midmark directly 1 800 Midmark 1 800 643 6275 or 937 526 3662 8 00 am until 5 00 pm Monday through Friday EST excluding standard U S holidays Go To Table Of Contents Specifications Weights Dimensions Electrical Specifications Maximum Patient Weight seeeeeees 300 Ibs 136 kg Weight of Table 45 tabletop W o scale unpackaged 315 Ibs 142 kg 45 tabletop w scale unpackaged 320 Ibs 145 kg 45 tabletop w o scale with packaging amp skid 372 Ibs 169 kg 45 tabletop w scale with packaging amp skid 377 lbs 171 kg Range of Motion amp Dimensions ess see illustration below Electrical Requirements seseeeeees Dedicated Circuit 115 VAC 60Hz 10A Power COPS euenit ette Meier bien 4 ft 121 cm long Duty Cycle actuator run time sss Intermittent Operation 1 minute ON 9 minutes OFF Range of Motion amp Dimensions 555 y 141 cm 46 5 _ 118 1 cm ah 60 25 5 152 4 cm 64 8 cm 5 5 14 cm ie Max w Pad 6 cm
7. nt flammables and liquids from entering the scale head Allow adequate clearance on all sides of scale platform to ensure accuracy Do not drop large loads onto the scale platform Never exceed the rated capacity of the scale Do not operate in close proximity to RF transmitters There are two 2 controls located on the display UNITS Toggles the displayed weight between pounds Ibs and kilograms kg ZERO Resets the display to indicate zero 0 0 Note The scale will not respond to the ZERO control under these conditions Motion on Scale An under load condition less than 0 1lbs or 50g An over load condition more than 300lbs or 1kg Go To Table Of Contents Operation Scale continued Weighing an animal without a cage e Zero scale 0 0 place animal on center of platform and read the weight displayed Note A blank scale while weighing means excess motion is detected and weight averaging is in process Once completed the scale will display and HOLD the recorded weight Adding additional weight while in the HOLD condition will NOT change the display Weighing an animal with a cage e Place empty cage on center of platform then zero scale 0 0 Remove cage from platform scale will read negative weight _ _ e Place cage with animal on center of platform and read record weight To continue to weigh animals in same sized cage lace next cage with animal on center of platform and
8. read record weigh do not zero scale Troubleshooting Symptom or Error Possible Problem and or Remedy No Display Power is OFF Table is unplugged from the power source Incorrect weight Interference with scale platform Ensure there is nothing in contact with the sides of the scale platform Ensure the correct UNIT of measure is selected Display segment s Low or intermittent voltage Unplug for one 1 minute to missing illegible reset system then reconnect to original power source Disconnect power cord and use different power source ZERO key does Motion or activity on the scale Remove source of motion not reset to 0 0 Ensure platform is level and supported evenly at corners Weight on scale may exceed the zero limit Unplug for one 1 minute to reset system Display locked amp System Error Unplug the unit for one 1 minute to reset system will not change then reconnect to original power source Displays HiLoAd Weight on scale exceeds capacity Remove excess load Displays HiLdX The load placed on the scale is too heavy on a corner shown as X Move load to center of the scale platform Displays LoLdX The scale is under loaded Ensure that tabletop cover pins are properly seated on load cells If the problem cannot be resolved using the above corrective actions please contact Midmark at 1 800 Midmark 1 800 643 6275 or 937 526 3662 Go To Table Of Contents Mainten
9. sult operating instructions for the device before use WARNING When using high frequency surgical devices or endocardial catheters Failure to comply may result in electric shock or burns to patient Go To Table Of Contents Operation M Table Up Down Hand Switches To move the table top UP or DOWN Press and hold either switch Press the upper portion to raise table or lower portion to lower UP Note Movement automatically stops Ec at the max min height This table is also equipped with a safety feature that disables the DOWN down function when something is encountered under the table Pi VA101900i Table Up Down Foot Control To move the table top UP or DOWN Press and hold the appropriate switch Note Movement automatically stops at the max min height This table is also equipped with a safety feature that disables the down function when something is encountered under the tpi VA102000i 5 Go To Table Of Contents Operation Scale optional The 300 pound capacity platform scale utilizes four 4 built in load sensors These electronic sensors are accurate within 5 grams and are protected against impacts moisture and liquid spills The scale has been calibrated and all parameters are preset so it should never need calibration CENTER OF ZERO O Equipment Alerts Preve
10. ufactured by Midmark 5 damage to mat caused by chewing 6 charges by anyone for adjustments repairs replacement parts installation or other work performed upon or in connection with such products which is not expressly authorized in writing in advance by Midmark EXCLUSIVE REMEDY Midmark s only obligation under this warranty is the repair or replacement of defective parts Midmark shall not be liable for any direct special indirect incidental exemplary or consequential damages or delay including but not limited to damages for loss of profits or loss of use NO AUTHORIZATION No person or firm is authorized to create for Midmark any other obligation or liability in connection with the products THIS WARRANTY IS MIDMARK S ONLY WARRANTY AND IS IN LIEU OF ALL OTHER WARRANTIES EXPRESS OR IMPLIED MIDMARK MAKES NO IMPLIED WARRANTIES OF ANY KIND INCLUDING ANY WARRANTIES OF MERCHANTABILITY OR FITNESS FOR ANY PARTICULAR PURPOSE THIS WARRANTY IS LIMITED TO THE REPAIR OR REPLACEMENT OF DEFECTIVE PARTS SF 1910 REV A Registration To register your product warranty go to www Midmark com Midmark Corporation 60 Vista Drive Versailles OH 45380 0286 1 800 643 6275 1 937 526 3662 www midmark com 12 MITMARI lt Because we care