Vario nursing table, 40-306XX-6
Contents
1. Es y g Da Tl n LU y a Du hi ps4 bW Ru TT ure oe ali yf N Better ways to better days Y Vario nursing table 40 306XX 6 User Manual Mounting Instructions PDF 6026 01 01 2011 General information Contents General information Part Numbers 3 Technical data 3 User Manual Daily use 4 User guide 4 After use 4 Recommendations in use D Mounting instructions Before mounting 6 Mounting to the wall T Electrical components Wire diagram 8 Connections 9 Hand control bracket 9 Labelling Label 10 symbol view 10 Fault finding 11 Maintenance Maintenance 12 Cleaning 12 Cleaning the mattress 12 Options Bed guard foldable 13 CE Marking 14 Complaints 15 A Product Information Product Vario nursing table height adjustable Producer Ropox DK 4700 Naestved Phone 45 55 75 05 00 Usability The height adjustable nursing table can be used to nurse children and adults up to 135Kg The nursing table can be used at home in day care centre or institutions to obtain good and correct working conditions for the caretakers at the same time it can also be used as a transfer help to other helping aids When not in use the plate can be folded up against the wall to save space By using the up A down VY button on the handheld control switch the height adjustment of the nursing table can be performed General information Part Numbers Length Width 70 Width 80 90 40 30619 6
2. max 130 Foam Cannot be washed 12 Options Bed guard foldable Foldable Bed guard in length 60 and 110 cm is available as an option We recommend mounting it in the centre of the worktop as shown on the drawing below The brackets will be mounted underneath the worktop with the screws Supplied We can also supply a fixed bed guard L 60 cm to be mounted at the end of the worktop To be mounted at the edge of the worktop Folding down Foldable Folding down Foldable RS ee ee 40 25706 40 25969 40 25706 40 25969 ee 40 25706 40 25969 40 25706 40 25969 40 25708 Foldable bed quard Folding down bed quard 13 Length Mattress W 70 40 25793 100 40 30602 40 25766 110 40 25768 120 40 25760 130 40 30605 40 25761 140 40 25795 150 40 25762 160 40 30607 40 25796 170 40 25763 180 40 25764 190 40 25765 Length Mattress W 80 40 25769 100 40 30620 40 25770 110 40 25771 120 40 25772 130 40 30623 40 25773 140 40 25774 150 40 25775 160 40 25776 170 40 25777 180 40 30628 40 257 78 190 40 30629 40 257 79 CE Marking EU Declaration of Conformity CE hereby declare under sole responsibility that the following products 40 30601 Nursing table Vario 90 x 7 0 cm 40 30619 Nursing table Vario 90 x 80cm 40 30602 Nursing table Vario 100 x 7 0 cm 40 30620 Nursing table Vario 100 x 80cm 40 30603 Nursing table Vario 110 x 7 0 cm 40 30621 Nursing table Vario 110 x 80cm 40 3060
3. other abrasives as they may scratch the paint and cover plates Also avoid the use of cleaning utensils with sharp edges Never use strong mineral acids or alkali Laminate worktop Clean the Etronit M surface with a soft cloth firmly wrung in hot water with a little liquid detergent The detergent should be without sulphonic soap as this may result in a greasy surface Stains that cannot be removed with water can often be removed with a mixture of equal parts chlorine bleaching and water or with acetone When using these products see that the room is sufficiently ventilated and note that these products should not be used on wooden edges Stains from felt tip pencils can be removed using methylated spirit and pencil strokes can be removed with a piece of eraser In case of doubt we recommend you experiment on a spot that cannot be seen as certain products may damage the laminate e g sulphuric acid etc some chemicals ink and strongly colouring fruit juices may cause discoloration if they remain on the table for a longer period of time as the pigmentation sticks to the surface Do not use steel wool scouring powder and other abrasive products or detergents leaving a film on the surface e g yellow soap After cleaning rinse with clear water and dry with a cloth or the like Mattress Canvas Recommended cleaning detergent Normal soap or alcohol the alcohol can be used undiluted Machine washable at max 95 and can be dry tumbled at
4. up or down by using the hand control Hand control defect Waist handling Check if Main power connected 230V Motor is connected to control box Hand control is connected to control box Motor are over loaded Check if Nursing table works with another hand control ST Used equipment shall de disposed according to the National law We recommend to dismount the product to the greatest extent possible in a way that most parts can be reused Be aware that this product contains electronically components Example for groups this product can be sorted in metal plastic cables electronics and parts for destruction Factors affecting the operation Temperature relative humidity 5 C to 45 C 5 to 85 non condensing Factors affecting storage and transport Oe eit 11 Maintenance and cleaning Maintenance The nursing table is maintenance free All mowing parts have been lubricated For safety reasons it is recommendable to check all mounting screws and moving parts to be sure all is tightened ok Also check the cables are not damaged and can move freely The Laminate worktop is maintenance free Cleaning the nursing table To clean the nursing table do not use a high pressure washer The bathtub is not machine washable Simply use a soft cloth or sponge with soapy water of max 60 C Always clean the nursing table after use to prevent dirt from sticking to the surface Important Do not use scouring powder or
5. 100 40 30620 6 110 40 30621 6 120 40 30622 6 130 40 30623 6 140 40 30624 6 150 40 30625 6 160 40 30626 6 170 40 30627 6 180 40 30628 6 190 40 30611 6 40 30629 6 Technical data Vario nursing table Electrical connection 230V 50Hz max 2 0A Used parts are type B Duty cycle Height Material Frame Plate Surface treatment Maximum load Max 10 2 min 18 min Work surface 33 103 cm incl mattress Unit B 71 cm H 114cm D 15cm Welded steel tubes St 37 Stainless and aluminium White laminated chipboard Powder coating white RAL 9010 matt Chromate 135 kg Technical data Mattress Product Height Length x width Material Maximum load CE Mattress with slip resistant base layer 3 cm Like work plate see Part Number scheme Canvas Dahlia 9317 type HR3836 light gray Foam PUR type 9527 HR 40 135 kg This product has CE marking according to Medical equipment Low Voltage and EMC directives Has been tested according to the European standards DS EN ISO 12182 and DS EN ISO 60601 1 This product is in risk group 1 User Manual Daily use Before start using this product be sure that Mains power has been connected as described in electrical connections Make sure that the mattress is lying stabile on the plate having the slip resistant surface between the mattress and the plate User guide Adjust the height of the nursing table between 33 103cm to obtain good and correct work
6. 4 Nursing table Vario 120 x 7 0 cm 40 30622 Nursing table Vario 120 x 80cm 40 30605 Nursing table Vario 130 x 7 0 cm 40 30623 Nursing table Vario 130 x 80cm 40 30606 Nursing table Vario 140 x 70 cm 40 30624 Nursing table Vario 140 x 80cm 40 30607 Nursing table Vario 150 x 7 0 cm 40 30625 Nursing table Vario 150 x 80cm 40 30608 Nursing table Vario 160 x 70cm 40 30626 Nursing table Vario 160 x 80cm 40 30609 Nursing table Vario 170 x 70cm 40 3062 7 Nursing table Vario 170 x 80cm 40 30610 Nursing table Vario 180 x 7 0 cm 40 30628 Nursing table Vario 180 x 80cm 40 30611 Nursing table Vario 190 x 7 0 cm 40 30629 Nursing table Vario 190 x 80cm are all under Classification Class and in conformity with the following directives and standards DIRECTIVES e The Council Directive No 93 42EEC concerning Medical Devices amended through Directive No 98 79 EC e 73 23EEC Directive for Low voltage amended through Directive No 93 68 EEC e 89 336 EEC EMC Directive amended through Directives No 92 31 EEC and 93 68 EEC STANDARDS DS EN 1041 2009 DS EN ISO 10993 1 2009 DS EN 14971 2008 DS EN 60601 1 CORR 2006 DS EN 12182 2002 DS EN 60601 1 2 2007 DS EN ISO 9999 2009 Dato 17 07 2009 m direktor 15 Complaints See General Terms of Sale and Delivery on www ropox com
7. e removed Ti a 2 screws in upper coverplate Un O LO O 4 screws in lower coverplate Mounting Instructions Mounting to the wall Attach the frame securely to the wall by using adequate bolts and raw plugs suitable for the type of wall construction material on site Nursing table is tested according to a load of up to 135 kg applied to the worktop The attachment holes can be marked up on the wall several possibilities in the top and two in the bottom of the frame Place the frame against the wall and make sure it is horizontal The frame is standing on two adjustable feet The holes in the frame are 8 5 mm and 6 mm in the top and 12 below Remove the frame and drill the holes After mounting make sure that the chain is in correct position on the sprocket also check that O8 5 cable plugs is connected correctly to the control Dox Sprocket Mount the cover plates Connect the main power Control and the nursing table is box ready to be used Adjustable feet Electrical components Wire diagram The nursing table is delivered with the control box already mounted on the frame The diagram shows how the cables are connected to the control box O1 amp NN Control box Z fan EE Mains cable 230V Motor connects to plug 4 End plug connects to plug 1 2 amp 3 Control switch All the plugs are water tigh
8. ing conditions for the caretakers By using the up A down V bottom on the handheld control switch the height adjustment of the nursing table can be performed The control switch has a spiral cord which can be pulled out to a length of 200cm Incl mattress After use When not using the nursing table the plate can be folded up against the wall This way it will only take up the space of approx 20cm from the wall At the pivot point a gas damper is mounted to reduce the power needed movement when folding up or down Recommendations in use Recommendations in the use of the height adjustable Nursing table The height adjustable nursing table helps the caretaker to obtain the most optimal working height Height adjustment allows you to customize the working height to the individual employee and can also save unnecessary lifting By using the up A down bottom on the handheld control switch the height adjustment of the Nursing table can be performed The control switch has a spiral cord which can be pulled out to a length of 200cm To ensure optimum utilization of the changing table features and avoid accidents it is important to observe some basic safety procedures e NEVER leave a person on the nursing table unattended not even for a very short period e The Nursing table must be operated by adults The Nursing table is a working tool and not a toy e Pay particular attention to o
9. its own label as shown The label contains much information which i s very important to specify when contacting your supplier It also shows main power supply Item No NN ROPOX A S SERIAL NO N40 1671 40 30628 7 Name model 2 min continous use at max Load herafter 18 min rest Sym oO gt gt fo M 10 DK 4700 Naestved Phone 55750500 Fax 55750550 Seriel No nummer __ Puslebord VARIO 180x80 cm Main power 230Vac 50Hz Rating 230Vac 50Hz 2 0 A IP66 Intermittens 10 2 min ON 18 min OFF Max consumption 2 0A Ingress Protection class for MAX LOAD 135KG ODN L dust amp water intrusion See explanation below Production year amp Max Load at nursing table month 135kg bol view User Manual must be read before use Waste must be sorted Most parts for re use NEMKO approval DEMKO approval SEMKO approval Type B equipment As for EN 60601 1 Class 2 equipment Without earth connection CE marking This product complies to the demands for general safety and functionality in the relevant EU directives and standards EMC information The nursing table comply to the demands for electromagnetic compatibility EMC if installation and daily use is according to instructions in this Manual In seldom situations the nursing table might be affected by electronic signals from ex Portable computers cell phones etc Fault finding Fault finding Nursing table do not move
10. t and therefore they can be a little tricky to connect disconnect Make sure that the plugs are positioned correct before they are pushed into the sockets at the control box The plugs must be pushed into the sockets until the O ring is no longer visible Motor control box and control switch apply to IP66 This means that they are dust tight and protectied against heavy seas or powerful jets of water The electronic system are designed for periodical use only this means a max duty cycle of 10 2min on 18min off Electric components Connections Motor cable connects to plug 4 Plug 1 2 amp 3 are not in use and blocked Control switch connects to HB When all cables has been connected use the safe locking bracket Pushed in until you hear a click Mains cable connects to the plug at the Safe locking side of the box bracket Disconnections Mains cable can be pulled out no safe locking bracket Before the other cables can be disconnected the safe locking bracket needs to be released removed Locking clips at each end of the safe locking bracket has to be released before the bracket can be removed and the cables can be disconnected Placement of the hand er control Su Bracket for hand control can be l placed at the wall as shown To be a mounted with the two screws that are a delivered with the bracket Labelling Label Each bathtub has
11. ther people in the room when using the nursing table Make sure that no children are playing under or with the table The nursing table is not a playground e Keep the hand control out of the reach of children Make sure that they cannot operate the table unattended A bracket for wall mounting is included with delivery e Make sure that there is free space above and below the nursing table to allow height adjustment The worktop is up foldable but please be aware of obsticles above below and around the worktop to prevent trapping risk e lf the control switch has been damaged or stopped working it has to be replaced immediately The up and down buttons are push and hold The motor stops when the button is being released This is a very important safety element e If two nursing tables are mounted next to each other we recommend to mount a side cover between to avoid the trapping risk e Although safety stop has been mounted constantly be aware of objects under the nursing table Mounting Instructions The nursing table is delivered fully assembled Before mounting the nursing table to the wall The mains cable for 230V has a length of 2 5m see left hand side of drawing The nursing table is delivered in the lowest position push the up A button and move the nursing table 30 35 op Disconnect the mains power Demount the two screws in the upper cover plate and the 4 screws in the lower cower plate The cover plates can b