Home

E18SGGSMGW Manual - Reliable Security Products Ltd.

image

Contents

1. GSM modem frequency 850 900 1800 1900 MHz Supported protocols Contact ID 4 2 Maximum number of users to whom SMS messages 3 are delivered Number of low level negative digital inputs 3 Allowable input values Voltage 0 1 45V current 0 8 0 6mA Input type NO normally open Number of outputs 3 Output circuit Open collector output Output is pulled to COM when turned on Maximum allowed output values Voltage 30V current 50 mA Dimensions 130 x 73 mm Operating temperature range 20 55 C Generated phone line voltage 18 V Generated phone line current 25 mA Generated phone line impedance 600 Q Dial tone frequency of generated phone line 350 Hz only Ei8SGGSMGW 4 42 protocol operates in communication mode 1 5 and 9 ONLY via GSM audio channel 5 Components Connections Pin amp LED Functionality 000 az So SIM CARD For configuration INFO STATUS GM O JP9 1 00 r 14 RING CI OC COM Q 22 ZI G 23 COM Figure 1 5 1 Component Functionality GSM MODEM GSM network 850 900 1800 1900 MHz modem SIM CARD SIM card slot holder ANT GSM antenna SMA type connector F1 Fuse model miniSMDC 500mA USB Mini USB port 5 2 Connector Functionality L1 L4 Landline or PBX contacts according to backup mode RING RING contac
2. as as IX SmartGuard E18SGGSMGW GSM Gateway Quick Guide 1 Safety Instructions Please read the following safety guidelines prior to installation e The SmartAccess GSM Gateway contains an integrated radio transceiver operating in GSM 850 900 1800 1900 MHz bands Do not install the system where it can interfere with other devices or cause any potential danger Do not mount the system next to medical equipment or medical devices Do not use the system in hazardous environments Do not expose the system to high humidity or in chemical environments The system must only be installed by a qualified engineer Any system repairs must be done only by qualified engineer The system must be powered by 10 24V DC The WEEE Waste Electrical and Electronic Equipment marking on this product or its documentation indicates that in the EU the product must not be disposed of together with household waste 2 Function The Ei8SGGSMGW is a device for transmitting data from alarm system to a monitoring station via e GSM audio channel e Telehone landline PSTN e GPRS network It can also send an SMS message to the user 3 Operation Description The Ei1i8SGGSMGW communicator acts as a gateway between the alarm system and monitoring station providing a dial tone and fully replacing the landline PSTN The communicator notifies the monitoring station EL8SGGSMGW ONLY and or the user by SMS message in case PSTN is unavailable ha
3. 8 Appendix 8 1 Restoring Default Parameters To restore the default parameters Disconnect the power supply Short circuit connect DEF pins Power up E18SGGSMGW for 7 seconds Disconnect the power supply Remove short circuit from DEF pins Parameters restored to default 8 2 SmartGuard Configuration Tool Software To configure the system please install the configuration software the SmartGuard Configuration Tool which can be downloaded from www rspl ie Before connecting USB cable to the computer please read the SmartGuard Configuration Tool user guide available in the HELP section of the software 8 3 Troubleshooting Problem Possible Reason GSM LED is off or not flashing e No external power supply e Circuit not properly connected e Blown fuse No GSM network signal STATUS LED flashing several times e SIM card not inserted improperly inserted second e PIN code enabled e SIM card inactive System does not send any SMS e SIM card credit limit exceeded messages e Incorrect SMS centre phone number No GSM network signal e User phone number is not preset Received SMS message Incorrect e Incorrect syntax Format Extra lt space gt character is left in SMS message or Command is not correct SmartGuard
4. Figure 4 for correct jumper position ld 6 2 Data Transmission from Alarm System to Preset User s by SMS In this mode the communicator retransmits Contact ID data sent from alarm system and decodes it to user understandable text format which is sent to preset user s by SMS message There is NO backup connection for this mode NOTE User phone number s must be set for the communicator using the SmartGuard Configuration Tool Please refer to software s HELP section for more details ATTENTION You must set a monitoring station phone number in the alarm system s digital communicator one digit is enough Figure 5 HO 1 B L4 RING TIP C1 DC COM C2 Z2 7 3 Z3 COM OOo OO RING TIP AUX AUX Figure 6 ALARM SYSTEM ies ie OO 1 Connect the circuit as indicated in Figure 5 connect telephone contacts of the alarm system RING TIP to RING TIP contacts of the communicator 2 W 2 Power the unit from the alarm panel 12V and 0 ug 3 Set the jumper on MODE pins See Figure 6 for correct jumper position O 6 6 3 Data Transmission from Alarm System to Monitoring Station via GSM Audio Channel and SMS Messages to Preset User s In this mode the communicator retransmits Contact ID data sent from alarm system to the monitoring station via GSM audio channel In addition the d
5. sets at name for a specified output Maximum allowed length is 23 characters S SMS Text XXXX_TCx NewOutputName Value TCx output number range TC1 TC3 Example 1111_TC2 Pump I Joutputon 9 This function switches a specified output ON SMS Text g XXXX_Cx ON or XXXX_OutputName ON Value Cx output number range C1 10 Output oFF This function switches a specified output OFF S SMS Text g XXXX_Cx OFF or XXXX_OutputName OFF Value Cx output number range C1 Output Pulse This function switches a specified output ON for a set period of time and switches ON the output back to OFF after the set period of time is over SMS Text z XXXX_Cx ON T or XXXX_OutputName ON T Value T period of time in seconds range 1 9999 Output Pulse This function switches a specified output OFF for a set period of time and OFF switches the output back to ON after the set period of time is over gt SMS Text z XXXX_Cx OFF T or XXXX_OutputName OFF T Value T period of time in seconds range 1 9999 A Telephone Line The delay period of time between telephone line failure and restore events If Failure Restore telephone line failure and restore events occur before the set delay period of time Delay is over the system will not send the SMS report SMS Text z XXXX_TELDLY_T Value T period of time in seconds range 1 250 11
6. the system from transmitting information 5 6 Communication Modes ATTENTION DTMF phone number dialling mode must be enabled on alarm system activated Contact ID or 4 2 data transmission protocol and monitoring station phone number set with international code i e 00353 Do not use the character ATTENTION Before connecting EL8SGGSMGW power supply to alarm system s auxiliary output AUX please ensure that the output is able to maintain peak current consumption of up to 700mA max Otherwise please use an external power supply for EL8SGGSMGW 6 1 Data Transmission from Alarm System to Monitoring Station via GSM Audio Channel No PSTN Connection In this mode the communicator retransmits Contact ID or 4 2 data sent from alarm system to the monitoring station via the GSM audio channel There is NO backup connection for this mode NOTE No additional communicator configuration is required for this mode Figure 3 Ey 3 L4 RING TIP C1 DC COM C2 Z2 ZI C3 Z3 COM RING TIP AUX AUX ALARM SYSTEM Figure 4 8 JP9 OO OO 1 Connect the circuit as indicated in Figure 3 above connect telephone contacts of the alarm system RING TIP to RING TIP contacts of the communicator z a 2 Power the unit from the alarm panel 12V and 0 3 jumpers have to be set any pins See
7. ata is duplicated and decoded data to user understandable text format and sent to preset user s by SMS message There is NO backup connection for this mode NOTE User phone number s must be set for the communicator using the SmartGuard Configuration Tool Please refer to software s HELP section for more details Figure 7 L1 12 13 14 RING TIP C1 DC COM C3 73 COM OO RING TIP AUX AUX ALARM SYSTEM a ae Figure 8 0 e 1 Connect the circuit as indicated in Figure 7 connect telephone contacts of the alarm system RING TIP to RING TIP contacts of the communicator a 2 Power the unit from the alarm panel 12V and 0 3 Set the jumper SET pins See Figure 8 for correct jumper position 1o 6 4 Data Transmission from Alarm System to Monitoring Station via PSTN using GSM Audio Channel as Backup Connection In this mode the communicator retransmits Contact ID and 4 2 data via landline PSTN sent from the alarm system to the monitoring station The communicator also monitors the voltage dial tone monitoring optional on the PSTN and in case the PSTN is unavailable disconnected or cut off voltage drops below 4V the system e switches to backup connection GSM audio channel e notifies the monitoring station about PSTN failure e continues transmitt
8. ing data to the monitoring station via GSM audio channel until the PSTN is restored NOTE Notification about PSTN loss restore if required has to be enabled for the communicator using the SmartGuard Configuration Tool Please refer to software s HELP section for more details Figure 9 O L1 12 13 L4 RING C1 DC COM C2 Z2 Zi c3 73 COM To o PSTN RING TIP AUX AUX ALARM SYSTEM 1 Connect the circuit as indicated in Figure 9 connect telephone contacts of the Jp8 Jpg _ alarm system RING TIP to RING TIP contacts of communicator ow Figure 10 2 Connect L3 L4 contacts to landline PSTN 3 Power the unit from the alarm panel 12V and 0 m 4 Set the jumpers on JP8 and JP9 pins See Figure 10 for correct jumper position i Q 6 5 Data Transmission from Alarm System to Monitoring Station via PSTN using GSM Audio Channel as Backup Connection and SMS Messages to Preset User s In this mode the communicator retransmits Contact ID data via landline PSTN sent from alarm system to monitoring station The communicator also monitors the voltage dial tone monitoring optional on the PSTN and in case the PSTN is unavailable disconnected or cut off voltage drops below 4V the system e switches to backup connection GSM audio channel notifies monitoring station about PSTN failu
9. m Text in case the input is violated Manufacturer default input alarm texts Z1 Input 1 TRIGGERED Z2 Input 2 TRIGGERED Z3 Input 3 TRIGGERED This command sets an alarm text for a specified input Maximum allowed length is 23 characters including space characters S SMS Text XXXX_TZxX ON NewAlarmText Value TZx input number range TZ1 TZ3 Example 1111_TZ3 ON Sensor violated J Each input has a restore text which is sent by SMS message to a preset user s in case the input is restored Manufacturer default input alarm texts Z1 Input 1 RESTORED Z2 Input 2 RESTORED Z3 Input 3 RESTORED This command sets a restore text for a specified input Maximum allowed length is 23 characters including space characters Set Input Restore Text SMS Text XXXX_TZx OFF NewAlarmText Value TZx input number range TZ1 TZ3 Example 1111_TZ3 OFF Sensor restored 9 Disable Input This command disables a specified input By default all inputs are enabled SMS Text XXXX_Zx OFF Value Zx input number range Z1 Z3 Example 1111_Z3 OFF Enable Input This command enables a specified input SMS Text XXXX_Zx ON Value Zx input number range Z1 Z3 Example 1111_Z1 ON Set Output Each output has a name which is sent by SMS to a preset user s Manufacturer Name default output names C1 Outputi C2 Output2 C3 Output3 This command
10. m alarm system to the monitoring station this indication is possible when device is operating in communication mode 1 On Device is decoding Contact ID data to user understandable text format 5 8 Wiring Diagram E18SGGSMGW The COM connectors of E1L8SGGSMGW and Alarm System unit must be connected E1L8SGGSMGW Inputs Z1 Z3 are connected to outputs of alarm system unit if PGM output is implemented as open collector X DEE COM circuit or any other circuit and if it commutes with COM The 8 98 E18SGGSMGW C1 C3 outputs can be connected to the inputs of other electronic devices This connection allows you to control heating lighting gates blinds water pump etc z Figure 2 1 Make sure that SIM card PIN code is disabled PIN code can be disabled by putting SIM card into a mobile phone 2 Insert the SIM card into the holder 3 Terminate the Input and Output connections first before adding o gt power 12V 4 The system will start in less than a minute Al arm system 5 LED2 indicator should flash or will be ON indicating connection to h the GSM Network or other appliance ATTENTION The system is not compatible with pure 3G SIM cards Only 2G SIM cards and 3G SIM cards with 2G profile enabled are supported For more details contact your GSM operator NOTE Pay as you go SIM cards are not recommended for use with the system as an insufficient credit balance will disable
11. rd In order to configure and control EL8SGGSMGW system using SMS message send the text command to E18SGGSMGW SIM card phone number from one of the authorized phone numbers The structure of SMS message consists of 4 digit SMS password the default SMS password is 0000 four zeros the command and the parameters For some commands the parameters are not applied i e STATUS E18SGGSMGW notifies the user if a mistake was made in SMS command Command is not correct Password The 4 digit SMS password intended for system configuration and control via SMS messages Manufacturer default SMS password is 0000 four zeros which is NECESSARY to change SMS Text z 0000_PSW_XXXX Value XXXX new 4 digit password 8 Status The SMS report indicating information on system input and output status z SMS Text XXXX_STATUS Set User Phone The system supports up to 3 user phone numbers which can receive input alarm Number and restore texts by SMS User 1 phone number is mandatory while other phone number entries are optional All numbers must be entered starting with international country code e g country code area code local number Do not use the plus symbol S SMS Text B XXXX_NRx country code area code local number Value NRx user phone number entry range NR1 NR3 I Set Input Each input has an alarm text which is sent by SMS message to a preset user s Alar
12. re sends an SMS report to the preset user s PSTN failure continues transmitting data to monitoring station via GSM audio channel until the PSTN is restored duplicates and decodes data to user understandable text format and sends it to preset user s by SMS message until the PSTN line is restored NOTE User phone number s must be set and notification about PSTN loss restore if required has to be enabled for the communicator using the SmartGuard Configuration Tool Please refer to software s HELP section for more details for more details Figure 11 Li 12 13 14 RING TIP C1 DC COM Gl 2 c3 273 COM To landline PSTN RING TIP AUX AUX ALARM SYSTEM JP8 JP9 Figure 12 1 Connect the circuit as indicated Figure 11 connect telephone contacts of the m alarm system RING TIP to RING TIP contacts of communicator Connect L3 L4 contacts to landline PSTN Power the unit from the alarm panel 12V and 0 Set the jumpers on JP8 JP9 and SET pins See Figure 12 for correct jumper position AWN Qa SET O O MODE 7 SMS Commands ATTENTION In this user manual the underscore _ character represents one lt space gt character There must be no spaces or other characters at the beginning and at the end of the message XXXX 4 digit SMS passwo
13. s been cut off or disconnected by PSTN provider EL8SGGSMGW supports only outgoing calls DTMF number dialling mode in the alarm system must be enabled The E1i8SGGSMGW features several communication paths between an alarm system and monitoring station GSM audio channel PSTN using GSM audio channel as backup connection SMS messages to preset users PSTN using GSM audio channel as backup connection with data duplication to preset users via SMS GPRS network PSTN using GPRS network as backup connection Please refer to section 6 Communication Modes for more details The Ei18SGGSMGW has 3 digital inputs normally open for sensor connection The 3 open collector outputs allow you to connect and control up to 3 electronic appliances on receipt of SMS text message s from one of the pre programmed phone numbers This feature provides control of heating lighting gates blinds etc The SmartGuard Configuration Tool software is used to configure the system to operate in one of its communication modes providing data transmission either via SMS text message or via GPRS The device has to be connected to the computer using a USB cable Please refer to software s HELP section for more details This software can be downloaded from the Reliable Security Products Website www rspl ie CE 4 Electrical amp Mechanical Specifications Power supply 10 24V 300 mA max Current used in standby mode 120mA
14. t TIP TIP contact 1 Outputs DC Positive power supply contact COM Negative power supply contact Common contact Zi 73 Inputs N A Not available 5 3 Pin Functionality Labelling Description DEF For restoring factory default settings SET For enabling communication modes MODE For enabling communication modes JP8 JP9 For communication backup connection UART Not Used 5 4 LED Functionality Labelling Description INFO Mode indicator STATUS Device activity indicator GSM GSM network quality indicator 5 5 GSM Signal Strength Indication GSM signal strength is indicated by the GSM LED To ensure best network signal adjust the position of GSM antenna and find the strongest possible signal by observing the GSM LED indications GSM LED Indication GSM Signal Strength Off No connection Flashing every 3 seconds The connection is not reliable Flashing every 1 second Satisfactory Flashing several times per second Good On Excellent 5 6 Device Activity Indication STATUS LED Indication Meaning Off No power supply or some fault is present Flashing several times per second SIM card is not inserted inserted improperly On Device is operating and ready for use 5 7 Working Mode Indication INFO LED Indication Meaning Off Device is in standby mode Flashing several times per second Device retransmits the data sent fro