Home

89352 TH10 Manual - Forestry Suppliers, Inc.

image

Contents

1. Alarm Yellow single flash every 10 sec Logging low alarm for TEMP Yellow double flash every 10 sec Logging high alarm for TEMP Yellow single flash every 60 sec TH10 memory full Download data kk To save power the TH10 s LED flashing cycle can be changed to 20s or 30s via the supplied software To save power alarm LEDs for temperature can be disabled via the supplied software When the battery is low all operations will be disabled automatically NOTE Logging automatically stops when the battery weakens logged data will be retained The supplied software is required to restart logging and to download logged data TH10 V1 0 9 07 Specifications Temperature Overall Range 40 to 158 F 40 to 70 C Accuracy 40 to 10 and 40 to 70 C 2 C Accuracy 10 to 40 C 1 C Accuracy 40 to 14 and 104 to 158 F 3 6 F Accuracy 14 to 104 F 1 8 F Logging rate Selectable sampling interval From 2 seconds up to 24 hours Operating temperature 31 to 176 F 35 to 80 C Battery type 3 6V Lithium 1 2 AA SAFT LS14250 Tadiran TL 5101 or equivalent Battery life 1 year typ depending on logging rate ambient temperature amp use of Alarm LEDs Dimensions Weight 4x1x 9 101x25x23mm 60z 172g 10 TH10 V1 0 9 07 Battery Replacement It is highly recommended that the battery be replaced every 12 months or prior
2. the supplied program disk in the PC s CD ROM drive If the installation program does not automatically open and provide on screen prompts open and browse the CD ROM drive then find and double click on the SETUP EXE file included on the program disk Follow the on screen prompts to complete the installation Before running the graphing software please connect the TH10 to the PC and install the USB Driver software as described in the next section INSTALLING THE USB DRIVER Plug the TH10 into an available USB port on the PC If this is the firsttime that the TH10 has been connected to the particular port on the PC the following screen will appear FoundiNew Hardware Wizard Welcome to the Found New Hardware Wizard This wizard helps you install software for Silabs C8051F320 USB Board If your hardware came with an installation CD lt 4 or floppy disk insert it now What do you want the wizard to do Install the software automatically Recommended Install from a list or specific location Advanced Click Next to continue Make sure the program disk is still in the PC CD ROM drive Select the recommended installation and follow the on screen prompts to complete the driver installation If this is a repeat connection of the TH10 to the USB port the driver installation process will be automatically skipped RUNNING THE GRAPHING SOFTWARE With the TH10 inserted into the PC s USB port double click
3. TANT was selected in the SETUP window the TH10 begins logging at the instant the SETUP button is pressed If MANUAL was selected the TH10 must be manually started by pressing and holding the device s yellow button for approx 3 seconds or until the two LEDs on the TH10 flash at the same time Logging will continue at the programmed sample rate until the number of readings sample points specified in the Setup window is reached The green LED flashes once per sample point and the red or yellow LED flashes when user programmed alarm limits are exceeded For details see LED status guide DATA DOWNLOAD To transfer the readings stored in the TH10 to the PC A Connect the TH10 to the same USB port used when the TH10 was initialized B Open the graphing software program if it is not still running C Click the Download icon 1 on the left or select Data Download from the LINK pull down menu D The Window shown below will appear Press DOWNLOAD to begin transferring readings Connected Download Press Download to stop logging and load data from logger or Cancel to exit If the readings are successfully transferred the VIEW screen and the SAVE screen both shown below will appear In the SAVE screen name the file and save it to a convenient location The data is saved as an rec file for use in this program only At a later time the user can select SAVE AS and save the data as an Excel Text or Bitmap file explained in next sect
4. User s Guide EXTECH INSTRUMENTS Temperature Datalogger Model TH10 EXTECH mmo Temperature Datalogger 1 TH10 V1 0 9 07 Introduction Congratulations on your purchase of the Relative Humidity and Temperature Datalogger This datalogger measures and stores up to 32 000 temperature The user can easily set up the logging rate high low alarm and start mode and download the stored data by plugging the module into a PC s USB port and running the supplied PC software Temperature data can then be graphed printed and exported to other applications The data logger is supplied with a long life lithium battery which can typically allow logging for one year This meter is shipped fully tested and calibrated and with proper use will provide years of reliable service Features Memory for 32 000 readings Selectable data sampling rate 2s 5s 10s 30s 1m 5m 10m 30m thr 2hr 3hr 6hr 12hr 24hr Status Indication via Red Yellow LED and Green LED USB Interface for Set up and Data Download _User Programmable Alarm Thresholds for Temperature Analysis software used to view graph Long battery life Description 1 Protective cover USB connector to PC port Start button Temperature sensor Alarm LED red yellow Record LED green N Oo oO e pP DN Mounting clip 2 TH10 V1 0 9 07 Operation INSTALLING THE GRAPHING SOFTWARE Install the supplied Windows PC Datalogger Software by placing
5. e FILE pull down menu When prompted select a rec file saved earlier FILE PRINT To print a data graph window to a line or network printer click on the printer icon or select PRINT from the FILE pull down menu Note that color graph windows can be accurately printed on color printers Note The TH10 retains data in its internal memory until the user begins a new logging session Starting a new logging session clears all of the TH10 s stored readings be sure to save previous data before starting a new logging session 8 TH10 V1 0 9 07 TH10 LED STATUS GUIDE LEDs Record O Green LED Alarm O Record Alarm EXTECH r410 INSTRUMENTS Temperature Datalogger Red Yellow LED Meaning No LEDs flashing No logging in process Or No battery found Or Battery completely discharged Action Fit battery in place Replace the battery and download the data Record Alarm O Green single flash every 10 sec Logging no alarm Green double flash every 10 sec Delayed start To start Hold the start button until Green and Yellow LED flash Record O Alarm Red single flash every 10 sec Logging low alarm for RH Red double flash every 10 sec Logging high alarm for RH Red single flash every 60 sec Low Battery t Logging if enabled will stop automatically No data will be lost Replace battery Record O
6. for help NUM To zoom in and out of data regions there are several approaches 1 Use the mouse to click and drag a box around any data area to magnify the selected area 2 Click on the zoom magnifier icon tool on the menu bar 3 Select VIEW ALL or ZOOM OUT from the VIEW pull down menu In the example graph above the Temperature is represented by the solid red line the lines are known as traces The low and high alarm values for temperature are represented by the dashed red trace To customize the graph window select SHOW TRACES BACKGROUND GRID LINES and MASK POINTS from the VIEW pull down menu These options provide the following features SHOW TRACES Allows the user to select which data to view as a trace Temperature amp Alarms BACKGROUND Select background color scheme GRID LINES Add or remove grid lines from x and y axes MASK POINTS Places dots on the traces for the actual data points breaking up the continuous nature of a trace 7 TH10 V1 0 9 07 FILE OPEN FILE SAVE AS To save the transferred data in a format other than the proprietary rec format click the SAVE AS icon from the menu bar 4 from right or select SAVE AS from the FILE pull down menu The data can be saved in the following formats TEXT FILE txt EXCEL FILE xls BITMAP FILE bmp To open an existing data file for viewing on the data graph window click on the FILE OPEN icon on the menu bar 3 from left or select FILE OPEN from th
7. ion 5 TH10 V1 0 9 07 Save in B My Documents e ck EE Name Moc temp run rec 435363 rec testttt rec test 5467 rec Ma test 8 23 07 rec Wb testasa7a rer lt Size 63 KB 63 KB 17 KB 1 KB 17 KB 1 KR Type Logger Docu Logger Docu Logger Docu Logger Docu Logger Docu anner Darii Date Modified 9 6 2007 4 34 PM 9 6 2007 3 57 PM 9 5 2007 4 35 PM 9 5 2007 1 20 PM 8 23 2007 2 31 PM alaaiann7a s am Y A gt File name jac temp 4 Save as type Logger Files rec v Cancel In the screen below press VIEW to see the data graphically If there are no readings currently stored in the TH10 the program will let the user know via a warning screen Connected r Download 32000 points finished Press View to show graph or Cancel to exit View Cancel TH10 V1 0 9 07 When VIEW is pressed the Data Graph window appears The Data Graph window presents the transferred data in an x y graph format with Date Time represented on the horizontal axis and Alarm Limits represented on the vertical axis A Extech In rument RI aph iE 4 eej x File View Link Help 4 2 Gy El om i S 0 0 16 41 25 18 28 05 20 14 45 22 01 25 23 48 05 01 34 45 03 21 25 05 08 05 06 54 45 08 41 25 05 05 2007 03 05 2007 03 05 2007 05 05 2007 03 05 2007 03 06 2007 03 06 2007 05 06 2007 05 06 2007 05 06 2007 Tem perature Low Alarm T High Alarm T Press F1
8. matically synchronize with the PC date and time setting The MANUAL and INSTANT select buttons allow the user to start data logging immediately when the Setup window is exited INSTANT or at a later time MANUAL The LOGGER NAME field allows the user to select a unique name for the TH10 The SAMPLE POINTS field instructs the TH10 to take a fixed number of readings The SAMPLE RATE pull down menu instructs the TH10 to log readings at a specific rate The LED Flash Cycle can be set by the user longer cycle times help to extend the battery life The ALARM SETTINGS area of the SETUP window allows the user to set high and low temperature limits and disable the flashing of the TH10 s LEDs thereby conserving battery energy Once the changes have been made click on the SETUP button to save them Press the DEFAULT button to set the TH10 back to factory default conditions Press the CANCEL button to abort the setup 4 TH10 V1 0 9 07 Note Any stored data will be permanently erased when the user clicks on Setup To save the data before creating a new setup click Cancel and then download the data Note The battery may run out before the TH10 has finished collecting a specified number of sample points Always ensure that the remaining charge in the battery is sufficient to last the complete duration of your logging exercise When in doubt we recommend that you always install a fresh battery before logging critical data If INS
9. se improper wiring operation outside of specification improper maintenance or repair or unauthorized modification Extech specifically disclaims any implied warranties or merchantability or fitness for a specific purpose and will not be liable for any direct indirect incidental or consequential damages Extech s total liability is limited to repair or replacement of the product The warranty set forth above is inclusive and no other warranty whether written or oral is expressed or implied Lamy a Support line 781 890 7440 Technical support Extension 200 E mail support extech com Repair amp Returns Extension 210 E mail repair extech com Product specifications subject to change without notice For the latest version of this User Guide Software updates and other up to the minute product information visit our website www extech com Extech Instruments Corporation 285 Bear Hill Road Waltham MA 02451 Copyright 2007 Extech Instruments Corporation All rights reserved including the right of reproduction in whole or in part in any form 12 TH10 V1 0 9 07
10. the Temperature Datalogger icon to launch the program The main software screen will appear with the MENU BAR icons described as below Note When the TH10 is connected to the USB port the battery inside the device is discharged at a higher rate than normal To conserve battery life do not leave the TH10 connected to the USB port for a prolonged period of time 3 TH10 V1 0 9 07 MENU BAR DESCRIPTION The main menu for the software appears as follows Extech Instrument R110 Graph File View Link Help gt BR aa ni mn 2 From left to right the MENU BAR icons represent DATA DOWNLOAD LOGGER SETUP FILE OPEN FILE SAVE AS FILE PRINT VIEW ALL and ZOOM In addition the FILE VIEW LINK and HELP pull down menus are available here All of these functions are described in the following paragraphs LOGGER SETUP Click on the computer icon on the menu bar 2 from left or select LOGGER SET from the LINK pull down menu The Setup window will appear as shown below descriptions for each field in the Setup window are listed directly below the illustration Connected Basic Settings Current Time Manual Instant Logger Name QC Test Max 15 characters Sample Points 32000 Sample Rate Sec 2s v LED Flash Cycle 10s 20s 30s Alarm Settings LEDs flash for high and low alarm Temperature Low Alarm 0 High Alarm 40 Unit Celsius v Default Setup The CURRENT TIME field will auto
11. to logging critical data The TH10 does not lose its stored readings when the battery weakens or when the battery is replaced the data logging process will however be stopped and cannot be re started until the battery has been replaced and the logged data has been downloaded to PC Use only 3 6V lithium batteries Before replacing the battery remove the datalogger from the PC Follow diagrammatic steps 1 through 4 below NOTE Leaving the RHT10 plugged into the PC USB port longer than necessary will cause some of the battery capacity to be lost WARNING Handle lithium batteries carefully observe warnings on battery casing Dispose of in accordance with local regulations 11 TH10 V1 0 9 07 Warranty EXTECH INSTRUMENTS CORPORATION warrants this instrument to be free of defects in parts and workmanship for one year from date of shipment a six month limited warranty applies to sensors and cables If it should become necessary to return the instrument for service during or beyond the warranty period contact the Customer Service Department at 781 890 7440 ext 210 for authorization or visit our website www extech com for contact information A Return Authorization RA number must be issued before any product is returned to Extech The sender is responsible for shipping charges freight insurance and proper packaging to prevent damage in transit This warranty does not apply to defects resulting from action of the user such as misu

Download Pdf Manuals

image

Related Search

Related Contents

JSL Computer Manual - Jefferson Swim League  Bambi Bucket Operations Manual (All Models)  TECHNISAT DigiCorder HD S3  Erste Schritte mit Ihrem Smart Tab III  User guide - JCB Vacuum Cleaners  Cirugía estereotáxica en el tratamiento de los  startWARE-GHS-Ravin-E, Ravin-E Add  CenturyLinkTM High-Speed Internet Subscriber Agreement  Fit-Test Bitrex  UFL-1 取扱説明書  

Copyright © All rights reserved.
Failed to retrieve file