1. elentek USER GUIDE Electronic Engineering Technology CONTROL DISPLAY User Manual DIGITAL CONTROL PANEL SCESM 059 SMISE O gt y o Z Y ros My sy ISO 9001 ELENTER S R L ELENTEK S R L CONTENTS 1 SYMBOLS AND WARNINGS eu 5 2 GENERAL INFORMATION siscssccseccstsccnscccetecutsiccscscexecaastassacastcosiseuiecuensecesecasnisssecancens 6 3 WARNINGS uri E 7 4 GENERAL DESCRIPTION css dadas 8 5 INSTALLA HON curia AA 9 6 CONTROLPANEL siriana 10 6 1 Luminous indicators and control commandS nennen 10 7 KEY TO FUNCTIONS AND SETTINGS oocccocccocccconcccnccconoccnncconoccnncnonocconcnonoccnnononocoss 11 7 1 MAIN GISDIGY Tiscali 11 7 2 Activation of load in manual mode ooocccncccoccnnncccoonnnnnnnonnnonnnnonoconnnnnanonononanonoss 11 7 3 User programming in automatic mode iii 12 8 ALARM Sana 14 9 ASSISTANCE MENU PARAMETERS uu 0 nun 15 10 TROUBLESHOOTING ac nn 16 11 GENERAL CONDITIONS u aaa 17 11 1 Wadi 17 11 2 a AAA ica 17 Lio ISOS a 17 12 DECLARATION OF CONFORMITY resrrrerrreerreerereeeeee rene e reee rene e rese zionze 18 ELENTER S R L ELENTEK S R L 1 SYMBOLS AND WARNINGS This operation and maintenance manual uses the symbols outlined below to indicate risks that may arise in the event of failure to observe the instructions supplied This symbol corresponds to an immediate risk of death or s
2. 3 400V 10 50 60Hz The power line must be protected by a residual current circuit breaker Tighten the electrical cables on the relative terminals using a suitable tool correctly sized to avoid the risk of damage to the fixing screws Take care if using an electric screwdriver The electrical panel is designed for wall mounting using screws and plugs in the pre drilled holes at the corners of the enclosure or by means of brackets when present ELENTEK S R L 6 CONTROL PANEL 6 1 Luminous indicators and control commands Control Display O 9 60 O KEY TO LUMINOUS INDICATORS AND COMMANDS Display of values and programming Green led electric pump operating SETUP or multifunction button UP arrow button DOWN arrow button OK button ELENTEK S R L 7 KEY TO FUNCTIONS AND SETTINGS 7 1 Main display items On activation of the panel the display shows the following At the end of the start up sequence the main menu is displayed as described below This screen enables display of the electrical data as read by the DRYTEK 1 panel in real time 230V Power supply voltage reading 0 0A Current absorbed by connected load 1 0 y Power factor of connected load MAN X Panel set to manual mode VV YV V WV AUT X Panel set to automatic mode 7 2 Activation of load in manual mode On activation the panel always starts up in Automatic mode indicated by the asterisk X displaye
3. The second screen enables modifications to the maximum motor current PEEN value above which it is shut off due to current overload use the arrows to change the value To go to the next window press OK EXAMPLE To enable operation in manual mode read the load current value displayed e g 6 0 Ampere and check that this corresponds to the motor data plate specifications Enter the maximum current value increasing it by 10 15 with respect to the previously checked u asa ELENTEK S R L 7 3 3 RESET In the event of a dry running alarm minimum power factor the panel may attempt to reset automatically which can be programmable in minutes with the option of setting this function as sequential 4 reset times can be set in which the system automatically restarts after being blocked By default these values are set as shown alongside The first reset attempt is performed 5 minutes after the dry running alarm The second reset attempt is performed 10 minutes after the alarm The third reset attempt is performed 15 minutes after the alarm The fourth reset attempt is performed 20 minutes after the alarm N B On each reset screen use the arrows to modify any set times and press OK to go to the next screen After setting all times press OK to go to the screen for the reset cycle settings If the value O zero is set all automatic resets are blocked after the fourth attempt if the value is set to 1 one
4. all instructions herein The information and instructions in this manual refer to the standard use of this product in the event of special circumstances functions or applications not described in this document contact our service centre for assistance If technical assistance or spare parts are required when contacting the manufacturer always specify the identification code of the model and construction number as stated on the data plate Our service centre is available for any requirement or clarification The electrical equipment supplied must be installed indoors in a well ventilated environment within a temperature range of 5 to 40 C N B the information provided in this manual is subject to modifications without notice The manufacturer shall not be held liable for any damage caused in relation to the use of these instructions as they are to be considered guideline only Note that failure to observe the instructions provided in this manual may cause physical injury or damage to objects In any event all local and or current legislation must be observed at all times ELENTEK S R L 3 WARNINGS On receipt of the goods perform an inspection immediately to ensure that the equipment has not been damaged during transport If defects or missing material are found the client should promptly notify and in any event within 5 days of receiving the goods our retailer or in the event of direct purchases the Elentek service
5. centre The electrical panel must be used exclusively for the purpose and function as specified in design Any other application or use is to be considered improper and therefore hazardous A DANGER No parts of the panel must be disassembled without the official authorisation of Elentek any tampering with or modifications to the unit will render all terms of the warranty null and void All panel installation and maintenance operations must be performed by a specialised technician who is fully aware of the relevant current safety standards Always disconnect the unit from the power supply before maintenance or cleaning If the panel is not used for prolonged periods store the product in a clean and safe location protected against atmospheric agents and the potential risk of dropping falling In the event of a fire in the place of installation or the surrounding area avoid the use of water jets and use the appropriate extinguishing equipment and means powder foam carbon dioxide Install the equipment far from heat sources and in a dry and sheltered location in observance of the stated protection rating IP The installation of a safety device is recommended to protect the panel power line in compliance with current electrical standards DANGER CAUTION Elentek declines all liability in the event of the following Incorrect installation Use by personnel not adequately trained in the correct use of the panel S
6. 000 3 3 Piove di Sacco 01 04 2014 LEGAL REPRESENTATIVE Michele Borgato NOTE ELENTEK S R L elentek Electronic Engineering Technology ELENTEK SRL SOCIET UNIPERSONALE Via A Meucci 5 11 35028 Piove di Sacco PD ITALIA Tel 39 049 9730367 Fax 39 049 9731063 www elentek com info elentek com Vat No 04534630282 Cod MQ 0014 UK Rev 00 Em 04 2014
7. at the end of the fourth attempt the reset cycle is repeated continuously The system protecting the panel against dry running conditions activates the reset cycle according to the time intervals set and resumes the same reset cycle each time water is detected for more than 10 seconds A To exit the menu press SETUP ELENTEK S R L 8 ALARMS The measured power factor value is lower than the set value The display flashes and the alarm output is activated voltage free contacts NC C NO The system resets automatically according to the times set in the programming phase The load current absorption is higher than the set value The display flashes and the alarm output is activated voltage free contacts NC C NO The system is reset manually by pressing OK The measured mains voltage is too low The display flashes and the alarm output is activated voltage free contacts NC C NO The system is reset manually by pressing OK The measured mains voltage is too high The display flashes and the alarm output is activated voltage free contacts NC C NO The system is reset manually by pressing OK The phase sequence is incorrect or one or more phases is missing The display flashes and the alarm output is activated voltage free contacts NC C NO The system is reset automatically by turning the panel off and on again ELENTEK S R L 9 ASSISTANCE MENU PARAMETERS This menu is acces
8. ct sequence of the motor phase wiring Ensure that the input voltage on the electrical panel is adequate Check the input voltage on the electrical panel and set the correct minimum and maximum voltage values in the assistance menu see page 14 Ensure that the FLAT cable is connected correctly Ensure that the FLAT cable has not been damaged ELENTEK S R L 11 GENERAL CONDITIONS 11 1 Warranty The product warranty is subject to the general terms of sale of the company Elentek S r l Acknowledgement of the warranty depends on the strict and proven observance of the operating instructions in this booklet and application of the correct mechanical hydraulic and electro technical practices All products are covered by a warranty valid for 12 months which covers all construction defects of our products and includes the replacement repairs of defective parts The warranty will not be deemed valid in the event of tampering with the panel modifications without prior authorisation faults due to lack of or inadequate protection and or connection errors faults caused by exceeding data plate specifications normal wear and tear failure by installation personnel to observe the specified operating procedures accidental causes natural disasters of any kind such as fires flooding water or lightning The defective material must be delivered carriage paid to Elentek S r l who reserves the right to fina
9. d alongside the text AUT on display The operating mode can be changed by pressing the UP arrow to change to Manual mode or the DOWN arrow to change to Automatic mode Therefore to enable operation in Manual mode press the UP arrow the asterisk X is displayed alongside the text MAN and then press and hold OK The display then shows current absorption of the motor and the power factor values in real time the green led also lights up to indicate the electric pump is running On release of the OK button the motor is shut down N B in manual mode the load is activated and bypasses all alarms but in the event of a fault the display flashes and the user can press the DOWN arrow to view a description of the alarm ELENTEK S R L 7 3 User programming in automatic mode To access the user programming menu press and hold the SETUP button until the parameter settings menu is displayed maximum current 7 3 1 MAXIMUM CURRENT On access to the menu the first window enables modifications to the Pomer minimum power factor value below which the load is deactivated due to dry running conditions use the arrows to modify the value Per passare alla schermata successiva premere il pulsante OK EXAMPLE To enable operation in manual mode activate in no load conditions dry running check the power factor reading e g 0 65 and enter the minimum power factor increasing it by approx u FRA 7 3 2 MAXIMUM CURRENT
10. erious failure to perform scheduled maintenance Use of non original spare parts or parts not specific to the model Unauthorised modifications or interventions Partial or total failure to observe instructions ELENTEK S R L 4 GENERAL DESCRIPTION e Power supply 1 50 60Hz 230V 10 Single phase e Power supply 3 50 60Hz 400V 10 Three phase e Buttons for function selection and programming e Display for values Volts Amperes and alarms e Green led motor active e Adjustable electronic motor overload control e Motor control on 2 phases e Motor current overload protection adjustable e Protection of sequence phase e Protection of minimum maximum voltage adjustable e Protection against dry running adjustable power factor e Automatic reset from dry running status with 4 separate programmable times from 0 to 250 minutes e Protection of aux circuits and motor with fuses e Alarm output NC C NO resistive load 5A 250V e Door lock general disconnect switch e Provision for start up capacitor not included e Metal enclosure IP54 e Ambient temperature 5 40 C e Relative humidity 50 at 40 C condensate free ELENTEK S R L 5 INSTALLATION Ensure that the mains power supply specifications correspond to the voltage specified on the data plate of the electrical panel and motor connected then make the earthing connection before all other connections 1 230V 10 50 60Hz
11. erious physical injury or material damage When present take great care to observe warnings DANGER and instructions This symbol corresponds to a possible risk of death or serious physical injury or material damage Take care JE CAUTION Failure to observe the instructions in the presence of this symbol may lead to malfunctions and damage to equipment with possible consequent injuries to WARNING the operator gt Before performing any work on the electrical panel or system shut off the electrical power supply The electrical panel must be connected by a qualified electrician in observance of the relevant electrical standards Before any other operation ensure the installation is connected to an efficient earthing system After making the electrical connection check that all electrical panel settings are correct to avoid automatic start up of the electric pump gt ELENTEK S R L 2 GENERAL INFORMATION This manual must always accompany the relevant equipment and be conserved in an accessible location for consultation by qualified technicians assigned for operation and maintenance of the system The installer user is strongly recommended to carefully read all instructions and information in this manual before using the product in order to avoid damage or improper use of the unit which would also render the warranty null and void Before operating the equipment carefully read the manual and follow
12. l judgement of the cause of the said defects The Warranty applies exclusively to restoring the original product characteristics and does not cover material damage or physical injury 11 2 Maintenance The panel does not require routine maintenance provided that it is used within the operating limits and in observance of the instructions in this manual Special maintenance or repairs must be performed exclusively by authorised service centres In the event of repairs only original spare parts must be used The manufacturer declines all liability for material damage or injury to persons or animals caused by maintenance interventions performed by unauthorised personnel or using non original materials 11 3 Disposal In the event of disassembly and scrapping strictly observe local legislation regarding pollution Waste disposal according to material categories is recommended ELENTEK S R L 12 DECLARATION OF CONFORMITY ELENTEK Srl Unipersonale Via A Meucci 5 11 35028 Piove di Sacco PD ITALY hereby declares under ts sole responsibility that the machine Trademark ELENTEK CONTROL DISPLAY series complies with the provisions of the following EU directives and subsequent amendments Machinery 2006 42 EC European Directive 2006 95 EC Electromagnetic Compatibility 2004 108 EC and subsequent amendments in compliance with the following technical standards e EN 61439 e EN 61000 3 2 e EN55014 1 e EN 61
13. sed by simultaneously pressing the buttons SETUP UP and DOWN during activation of the panel This menu enables modifications to the language minimum and maximum voltage with the latter programmed by default as shown in the table below modify only if absolutely necessary If you change the operating limits beyond_the default parameters will result in immediate forfeiture of the guarantee Press OK to go to the next screen u aoe N B On each screen use the arrows to modify any set values and press OK to go to the next screen To exit the menu press SETUP ELENTEK S R L 10 TROUBLESHOOTING PROBLEM The panel is set to automatic mode but the pump does not start On pump start up the panel sets to alarm status ALARM MOTOR PROTECTION TRIP On pump start up the panel sets to alarm status ALARM DRY RUN On pump start up the panel sets to alarm status ALARM VOLTAGE TOO HIGH and ALARM VOLTAGE TOO LOW The display does not switch on CHECKS SOLUTIONS Ensure that a jumper is wired in on input G P if a float or pressure switch is not connected Ensure correct operation of the float or pressure switch connected to the input G P Check the maximum current settings in the user menu see page 12 Ensure correct operation of the motor used Check the minimum power factor settings in the user menu see page 12 On the 400V three phase model check corre