Vega Instruction Manual
Contents
1. and Pressure xx x cmH20 xx x is the numeric value of the air pressure the device first runs with the start pressure 5 minutes before the pre set delay time ends the air pressure begins to increase until it reaches the pre set value at the end of the pre set delay time then the device runs at the normal working mode with the pre set air pressure Use the procedure described in clause 3 to stop the device R404 1 Kamp Mask off warning In normal working mode or ramp mode if the mask falls off the patient s face there is a Mask off warning on the screen the LCD displays Mask Off meanwhile the backlight flashes at the frequency of 1 Hz for 1 minute Mask Off during Normal Working Backlight flashes at the frequency of 1 Hz wO Pressure 4 O Demko Mask Off during Ramp Backlight flashes at the frequency of 1 Hz The following are configuration operations 5 Press RAMP and at the same time in standby mode then press START OFF the configuration mode is on 6 The configuration first enters work pressure setting mode the LCD R404 1 displays Pressure xx x CcmH20 xx x is the numeric value of the air pressure you want to set to the device Use and to change this value the value will increase reduce 0 5 once with a single press and will take a fast change with a speed of 0 5 with continues press Work Pressure Setting finde f Press MODE
2. at the working air pressure setting mode the device enters the altitude setting mode there are 4 levels of altitude 1 2 3 and 4 which stand for 0 2500 feet 2500 5000 feet 5000 7500 feet and 7500 9000 feet respectively Set this with and according to the altitude of your current location Altitude Setting Salting Mode flashes ot the dreqeency of 1 Hr Altitude Press MODE at the altitude setting mode the device enters the air pressure calibrate mode The LCD displays Fine Adjustment Pressure X X X X is the compensation value use a manometer to measure the air pressure at the output port of the device and compare the measured value to the set value and then make the adjustments by using or For example if the measured value is 3 mmH higher than the set value it is proper to set x x to 0 3 The adjusting range of x is 3 to 3 the digital increment is 0 1 R404 1 Pressure Calibrate Setting ode flashes at the frequency of 1 Hz Press MODE at the air pressure calibrate mode the device enters the ramp time setting mode The LCD displays Delay Time xx min xx is ramp time Use or to change this value The ramp time adjusting range is 10 to 60 Ramp Time Setting Sebling Mode Rashes at the trequmcy af 1 Hr eT Delay Time yg Press MODE at the ramp time setting mode the device enters the starting air pressure s
3. Max 1 5A Air Pressure Range 3 cmH20 20 cmH2O Ramp Time 0 60 min Air Pressure Calibrate 3 cmH2O Working Flow 3 0 3m h 9 cmH 0 OO CO NID NIB W e Noise lt 33dB 9cmH2O 1m away Working Humidity 10 RH to 90 RH Working Temperature 5 C to 40 C 41 F to 104 F 10 Storage Humidity lt 95 RH 11 Storage Temperature 20 C to 60 C 4 F to 140 F 12 Dimension LxWxH 143 x 121 x 88mm 13 Weight 400g 14 Life of Use 3 years 15 Safety Criterion UL CE FDA V Operation Instruction Keys on the device MODE RAMP START OFF N Ss me Tubing Connection Di gt oo ubing connection Viagram ak x SS Ly A The following are normal operations 1 Turn on the power the LCD backlight is on at the same time the LCD displays OFF This is the standby mode R404 1 Stand By Press START OFF at the standby mode then the CPAP runs with an output of pre set air pressure meanwhile the LCD displays Pressure xx x CMH20 xx x is the numeric value of the pre set air pressure This is the normal working mode of the device Normal Working 29 8 Pressure U UscmH 0 Press START OFF at the normal working mode then the air pressure outputting stops and the device returns to the standby mode Press RAMP at the normal working mode CPAP runs at the ramp mode the LCD outputs RAMP
4. VEGA Continuous Positive Airway Pressure MODEL CP 03 ISO9001 amp ISO13485 Certified This device complies with EU EMC standard EN60601 1 2 Vega Technologies Inc 11F 13 100 Chang Chun Road Taipei Taiwan ec eer Biolife Ltd 203 Mesogion Av P C 115 25 Athens Greece VAT NO EL 999725460 Version 1 0 Date Nov 04 2009 C vase A ph READ THIS INSTRUCTION R404 1 MANUAL CAREFULLY BEFORE USE I Introduction The product name is CPAP Continuous Positive Airway Pressure The device uses a motor which drives a fan to create a continuous air pressure to force the air into the patient s lung through the nasal cavity so that the patient s airway is expedite which is the key to OSA Obstructive Sleep Apnea Syndrome therapy II Product Structure A Visual appearance R404 1 B Assemblies LCD panel upper cover LCD shelf upper cover of S ba ae ee motor case motor securing cushion back cover input port cushion lt i Loe R404 1 lll Important Safeguards Note Read all instructions carefully before use The following basic precautions are needed when using an electrical product Caution Failure to read and observe all precautions could result in personal injury or equipment damage Product cautions 1 To avoid electrical shock Keep the unit away from water Do not immerse the power cord or the unit in liquid Do not use while bathing Do not rea
5. ch for a unit that has fallen into water immediately unplug the unit 2 Never operate the unit if it has any damaged parts including power cord if it has been dropped or submersed in water Promptly send it to a service center for examination and repair 3 The unit should not be used where flammable gas oxygen or aerosol spray products are being used 4 Disconnect the unit from the electrical outlet before cleaning filling and after each use 5 Do not use other attachments unless recommended by manufacturer Operating Cautions Connect this product to an appropriate voltage outlet for your model 2 Do not run this product unattended 3 Never operate if this unit has a damaged cord or plug and if it has been dropped into water 4 lf any abnormality occurs discontinue use immediately until the unit has been examined and repaired 5 Always unplug the product immediately after use Storage Cautions 1 Do not store the unit under direct sunlight high temperature or humidity 2 Keep the unit out of reach of small children 3 Always keep the unit unplugged while not in use Cleaning Cautions 1 Do not immerse the unit in water It may damage the unit 2 Disconnect the unit from the electrical outlet before cleaning Clean all necessary parts after each use as instructed in this guidebook R404 1 IV Device Specifications No Description Power Supply 12V DC Current Consuming
6. d that the unit is disinfected after the last treatment of the day 1 Use one part white vinegar with three parts distilled water Make sure mixed solution is enough to submerge the air tube mouthpiece and mask 2 Complete Rinsing Steps 1 3 3 Wash air tube mouthpiece and mask in warm water and a mild detergent Then wash them in hot tap water 4 Submerge these parts in the vinegar and water solution for thirty minutes 5 Complete Rinsing Steps 3 5 Filter change 1 Do not wash or clean the filter And do not operate without a filter 2 Change the filter every 30 days or when the filter turns gray 3 Changing procedure A Replace the used filter with a new one Vil REPLACEABLE PARTS amp ACCESSORIES In order to provide appropriate treatment please use replaceable parts and accessories recommended below Air tube 70253 Breathing Anesthesia Tubing HSINER CO LTD Mask CPAP VPAP Masks FDA 510 K No K063268 HSINER CO LTD Power Adapter UE24WCP 120167SPA Dongguan Shilong Fuhua Electronic Co Ltd Heated Humidifier HH 02 Humidifier Vega Technologies Inc R404 1 Oo Pt e k Consult accompanying documents Type BF equipment Disposal for separate collection Device in protection class 2 R404 1
7. etting mode The LCD displays Ramp Start Pressure xx x cmH2 xx x is the numeric value of the starting air pressure Use and to change this value the value will increase reduce 0 5 once with a single press and will take a fast change with a speed of 0 5 with continues press Ramp Start Pressure Setting Sebting Mode flashes at the trequency of Hr Pressure 3 Sem In 6 7 8 9 10 symbol Setting will flash at the frequency of 1HZ R404 1 11 Press MODE at the starting air pressure setting mode the device enters the compliance time checking mode The LCD displays Compliance Hrs XXXxX X XXXX X is the compliance time of the device This value is not to be changed but only to be reset Press 2 seconds to reset it Compliance Hours for a period of time of 12 Press MODE at the compliance time checking mode the device enters the operation time checking mode The LCD displays Operation Hrs XXXX X XXXX X IS the operation time of the device This value is not to be changed but only to be reset Press for a period of time of 2 seconds to reset it Operation Hours 13 Press MODE at the operation time checking mode the device enters the total operation time checking mode The LCD displays Unit Hrs xxxx x XXxx X is the total operation time of the device after leaving factory This value is not to be changed but on
8. ly to be reset Press 4 4 within 2 seconds to reset it This combination should not appear in the user s manual R404 1 Unit Hours 9333 9 16 Press START OFF to leave configuration mode and return to standby mode 17 The configuration can also be done through CPAP PC application Connect the device and your PC with a USB cable then run CPAP software on your PC this software allows you to do most of the configurations on PC When the device is connected to PC it enters USB mode The pressure output will be stopped and the device will display USB on the screen Disconnect the USB cable the device goes back to Standby mode USB Cable Attached VI Cleaning and Sterilization It is recommended that the air tube and mask be thoroughly cleaned with hot water after each use and cleaned with a mild detergent after the last treatment of the day If your physician or respiratory therapist specifies a different cleaning procedure follow their instructions Rinsing after each treatment 1 Disconnect the air tube and mask 2 Rinse the mouthpiece and mask with water 3 Dry them with clean soft towel or let it air dry 4 Reassemble the product when completely dry and put these parts in a dry R404 1 sealed container Disinfections Please follow the following steps to disinfect your CPAP unless otherwise specified by your physician It is suggeste