Home

User Manual - Weighing Scales

image

Contents

1. EL OFF Backlight turned off Press Tare to store the setting 3 3 RS 232 SETUP The RS 232 interface uses parameters set by the user for language currency symbol baud rate date format and label format of the printout Press and hold the Print key for 4 seconds to access the parameters Press Print to scroll through the options and Tare to confirm the change and then advance to the next parameter When a parameter is entered by pressing Tare the displays will guide you through the parameter selected and the options available The parameters and their function are Displays Options Functions Weight Unit Price Total Price Port on on or OFF Enable or disable the RS 232 interface 4800 bPS 600 1200 2400 4800 9600 Set baud rate or 19200 LABEL 1 120r3 Select label format to print CoUntr Y E nGLiSH ENGLISH FrEnCH GErMAn or Select Language to be SPANISH printed StErLi nG EUroPE dOLLAr StErLinG Select currency Euro Dollar or Pounds Sterling Adam Equipment Company 2009 5 3 4 REAL TIME CLOCK SETUP The Real Time Clock RTC is used only for the RS 232 output The Date and Time can be set as required The scale will keep the clock running even when the power is off Steps Press and hold the CE key when power is first turned on release the key when the revision is displayed The displays show the current date a
2. AZextra No of the EC T7068 TC7072 Nr der EG T7068 TC7072 N du certificate T7068 TC7072 type approval Bauartzulassung d approbation certificate CE de type Corresponds to the production model described in the EC type approval certificate and to the requirements of the Council Directive 90 384 EEC as amended and to the requirements of the following EC Entspricht dem in der Bescheinigung ber die Bauartzulassung beschriebenen Baumuster sowie den Anforderungen der EG Richtlinie 90 384 EWG in der jeweils geltenden Fassung und den Anforderungen folgender EG Richtlinien Correspond au modele d crit dans le certificat d approbation CE de type aux exigences de la directive 90 384 CEE modifi e et aux exigences des directives CE suivantes Directives 2004 108 EEC Electrical equipment 2004 108 EWG Elektrische Betriebsmittel 2004 108 CEE Mat riel lectrique pour for use within certain zur Verwendung innerhalb utilisation dans des limites voltage limits Low bestimmter de tension d finies Voltage Directive Spannungsgrenzen Directive Basse Tension Niederspannungsrichtlinie 2006 95 EEC Electromagnetic 2006 95 EWG Elektromagnetische 2006 95 CEE Compatibilit compatibility Vertr glichkeit lectromagn tique This declaration is only valid when accompanied by a Certificate of Conformity issued by a Notified Body Diese Erkl rung gilt nur in Verbindung mit einer Konformit tsbescheinigung e
3. PLU 1 SAVEd or PLU 2 SNE followed by the PLU value displayed in the Unit Price window Adam Equipment Company 2009 3 Entering values for the PLU key e Press and hold down the key PLU for more than 3 seconds till a beep is heard then release the key It will show SAVE PoS 00 e f no number is entered for 00 within a few seconds the PLU entered will be saved for position 3 The display will show PLU 3 SAVEd and the scale will return to weighing Or Enter any number 00 up to 99 for saving the unit price in the desired position For example press 1 and 4 for the position 14 It will show PLU 14 SAVWEd before returning to weighing 2 0 RS 232 INTERFACE The AZextra scales include a bi directional RS 232 interface When connected to a printer or computer the scale outputs the weighing results using the RS 232 interface The scale can be controlled by sending commands from a PC See section 3 1 Specifications RS 232 output of weighing data ASCII code Adjustable Baud rate 600 1200 2400 4800 9600 and 19200 baud 8 data bits No Parity Connector 9 pin D subminiature socket Pin 3 Output Pin 2 Input Pin 5 Signal Ground 2 1 INPUT COMMANDS FORMAT The scale can be controlled with the following commands The commands must be sent in upper case letters i e T not t T
4. devices as defined by European Directive 2002 95 EEC must be recycled or disposed using techniques that do not introduce hazardous substances harmful to our health or the environment as listed in Directive 2002 95 EC or amending legislation Battery disposal in Landfill Sites is more regulated since July 2002 by regulation 9 of the Landfill England and Wales Regulations 2002 and Hazardous Waste Regulations 2005 Battery recycling has become topical and the Waste Electrical and Electronic Equipment WEEE Regulations are set to impose targets for recycling Adam Equipment Company 2009 9 EHEZADAM Adam Equipment ADAM EQUIPMENT BOND AVENUE DENBIGH EAST INDUSTRIAL ESTATE MILTON KEYNES MK1 1SW U K Tel 01908 274545 Intl Tel 44 1908 274545 Fax 01908 641339 E Mail Address info Adamequipment co uk Intl Fax 44 1908 641339 K Declaration of Conformity Konformit tserkl rung D claration de Conformit Verklaring van overeenstemming Dichiarazione di Conformita Declaraci n de Conformidad The non automatic weighing instrument Die nicht automatischen W geapparate L instrument de pesage fonctionnement non automatique Het niet automatische weegwerktuig Strumento per pesatura non automatico Imstrumento para pesaje non automatico Manufacturer Adam Equipment Co Hersteller Adam Equipment Co Fabricant Adam Equipment Co Ltd Ltd Ltd Type AZextra Typ AZextra Type
5. has been removed this key can also disable the auto clear function NOTE For South Africa and Far East unit weight per 100g or per kg is not available 1 4 USING A STORED PLU VALUE FOR UNIT PRICE Product Look Up PLU numbers are used to store information about the most commonly used items During the weighing operation the user can recall the cost per kilogram or per 100g of a particular item very easily using the PLU values The user can store and recall up to 103 PLU values as PLU1 PLU2 PLU3 and PLUOO to PLU99 The individual PLU values should be entered against specific items before the weighing process starts To recall one of these PLU values the following procedure applies e To recall PLU1 or PLU2 simply press PLU1 or PLU2 e Torecall one of the other PLU values press PLU The display will show LOAd PoS 00 Ifa number 00 to 99 is entered immediately then the value saved against the entered PLU number will be recalled If nothing is entered within a few seconds of pressing the PLU key the value saved for PLU3 will be recalled 1 5 STORING VALUES FOR THE PLU s To store values for the PLUs into the memory follow the procedure e Enter the unit price value using the keypad selecting either price kg or price 100g if needed Entering values for PLU1 and PLU2 keys e Press and hold down the key PLU1 or PLU2 for more than 3 seconds till a beep is heard then release the key The scale displays
6. E INFORMATION This manual covers the details of operation If you have a problem with the scale that is not directly addressed by this manual then contact your supplier for assistance In order to provide further assistance the supplier will need the following information which should be kept ready A Details of your company Name of your company Contact person s name Contact telephone e mail fax or any other methods B Details of the unit purchased This part of information should always be available for any future correspondence We suggest you to fill in this form as soon as the unit is received and keep a print out in your record for ready reference Model name of the scale Serial number of the unit Software revision number Displayed when power is first turned on Date of Purchase Name of the supplier and place C Brief description of the problem Include any recent history of the unit For example Has it been working since it s delivered Has it been in contact with water Damaged from a fire Electrical Storms in the area Dropped on the floor etc O Adam Equipment Company 2009 WARRANTY INFORMATION Adam Equipment offers Limited Warranty Parts and Labour for the components failed due to defects in materials or workmanship Warranty starts from the date of delivery During the warranty period should any repairs be necessary the purchaser must inform it
7. EHEADAM Adam Equipment AZ extra SERIES P N 3026610533 Revision A2 August 2009 Adam Equipment strives to be more environmentally focused and uses recycled materials and environmentally friendly packaging where possible As part of this initiative we have developed a short form manual that uses less paper and ink to describe the main functions of your new Adam scale A complete version is available at www adamequipment com Thank you for your support of Adam Equipment and we hope that you enjoy your new scale O Adam Equipment Company 2009 CONTENTS 10 OPERATION G EE 2 1 1 SETTING UP AND TURNING ON THE SCALES seeeeeeeseeeeereerrerrsern 2 1 2 ZEROING AND TARING anal A AA A RA 2 1 3 DETERMINING VALUE OF A PRODUCT BY WEIGHT 3 14 USING A STORED PLU VALUE FOR UNIT PRICE A 3 148 STORING VALUES FOR THE PLUS corsa listas iden lidiar 3 DER NT BREAGE E 4 2 1 INPUT COMMANDS FORMAT aia a 4 30 A EE 5 3 1 AUTO SLEEP FUNCTION 0 5 3 2 BACKLIGHT TEE 5 3 3 Ro 292 E 5 3 4 REAL TIME CLOCK SETUP E 6 40 ERROR CODES un a are eee aa 6 507 HALT RAGIN ci A AAA A AA E AE di ea AS AE AAC AA A A 6 6 0 SPEGIRIGATON Sra AAA A AA AAA 7 7 0 SERVICE INFORMATION KEE 8 O Adam Equipment Company 2009 1 1 0 OPERATION 1 1 SETTING UP AND TURNING ON THE SCALES Set your scale in a ventilated place Place the platform in the receptacles on the top cover If an optional scoop has been supplied place it on top of the pla
8. iner benannten Stelle Cette d claration est seulement valide quand elle est accompagn e par une Attestation de Conformit d livr e par un Organisme Notifi Fabrikant Adam Equipment Co Produttore Adam Equipment Co Fabricante Adam Equipment Co Ltd Ltd Ltd Type AZextra Modello AZextra Tipo AZextra Nummer van de T7068 TC7072 N di certificato di T7068 TC7072 Numaro del T7068 TC7072 Verklarling van EG typegoedkeuring approvazione di tipo CE certificado de aprobacion de tipo CE Conform met het model beschreven in de verklaring van EG typegoedkeuring en met de voorschriften van EG richtlijn 90 384 EEC zoals gewijzigd en met de volgende EG richtlijnen Conforme al modello di produzione descritto nel certificato di approvazione de tipo CE e secondo le richieste CE direttivo 90 384 CEE come modificato e secondo le rechieste della seguente directive CE Conforme al modello di producion descrito nel certificado di aprobacion del tipo CE e segun los requisitos del CE diretiva 90 384 CEE como modificato e segun los requisitos della siguiente diretive CE 2004 108 EEC Laagspanning richtlijn 2004 108 EWG Strumenti elettrici per uso 2004 108 CEE Instrumentos electricos entro certi limiti di para uso dentro cierti voltaggio Directivo di limites del voltaje voltaggio basso Diretivo di voltaje bajo 2006 95 EEC EMC richtlijn 2006 95 EWG Compatibilita 2006 95 CEE Compatibilidad electromag
9. lt cr gt lt lf gt Tares the scale to display the net weight This is the same as pressing Tare key Z lt cr gt lt lf gt Sets the zero point for all subsequent weighing The display shows zero P lt cr gt lt lf gt Prints the results to a PC or printer using the RS 232 interface O Adam Equipment Company 2009 4 3 0 PARAMETER 3 1 AUTO SLEEP FUNCTION This function may be enabled or disabled by the user If enabled when the scale is not used for some time as pre set by the user under this function it automatically switches off To set this parameter During self checking press Zero and release at once The display shows SLEEP node Press Print key to scroll through the auto sleep values Options are 0 1 5 10 0 Auto sleep mode disabled TT Auto sleep after 1 minute Y Auto sleep after 5 minutes 10 Auto sleep after 10 minutes Press Tare to set the value The scale returns to zero 3 2 BACKLIGHT OPERATION The backlight may be enabled or disabled by the user If the backlight is disabled the battery life will be maximised With the backlight in operation the battery life will be less depending on the extent at which the scale is used To set the backlight Press and hold the Auto Clear key for 4 seconds Press the Print key to change the operation El AU Automatic control of the backlight will turn on when the scale is being used EL on Backlight on full time
10. nd time set HC 11 14 06 16 41 35 Press the CE key to change the date and time The display will show the current time format H m S Enter the time using the numeric keys using a 24 hour clock format 3 41PM is 154100 Press the Tare key to accept the time The display will show the current date format Press the Print key to change the date format Available formats are Y m d year month day m d Y month day year d m Y day month year Press the Tare key to accept the chosen format and then enter the date in this format Press the Tare key to accept the date An error code will be shown if the time Err 1 or the date Err 2 is not the permissible values For example 34th day of a month is an invalid entry 4 0 ERROR CODES During the initial power on testing or during operation the scale may show an error message If an error message is shown repeat the step that caused the message If the error is still shown contact your dealer for further support ERROR DESCRIPTION POSSIBLE CAUSES Err 1 Time input error Tried to set an illegal time i e 26 hours Err 2 Date input error Tried to set an illegal date i e 36th day Err 4 Initial Zero is greater than Weight is on the pan when turning allowed typically 4 of the the scale on maximum capacity when Excessive weight on the pan when power is turned on or when zeroing scale Zero is
11. netico electromagnetico Deze verklaring is alleen geldig samen met een certificaat van overeenstemming afgegeven door een bevoegde instantie Questa dichiarazione e valida solamente se accompagniato da un certificato di conformita relaciato da un ente riconosciuto Esta declaracion es valida solamente si accompagniato a un certificado da conformidad emitida par un organismo notificado Signature Unterschrift Signature Handtekening Firma Firma J S Cumbach GC Technical Manager O Adam Equipment Company 2009 Date Datum Date Datum Date Fache 4 January 2007 ADAM EQUIPMENT is an ISO 9001 2000 certified global company with more than 35 years experience in the production and sale of electronic weighing equipment Adam products are predominantly designed for the Laboratory Educational Medical retail and Industrial Segments The product range can be described as follows Analytical and Precision Balances Compact and Portable Balances High Capacity Balances Moisture analysers balances Mechanical Scales Counting Scales Digital Weighing Check weighing Scales High performance Platform Scales Crane scales Medical Scales Retail Scales for Price computing For a complete listing of all Adam products visit our website at www adamequipment com O Copyright by Adam Equipment Co Ltd All rights reserved No part of this publication may be reprinted or tra
12. nslated in any form or by any means without the prior permission of Adam Equipment Adam Equipment reserves the right to make changes to the technology features specifications and design of the equipment without notice All information contained within this publication is to the best of our knowledge timely complete and accurate when issued However we are not responsible for misinterpretations which may result from the reading of this material The latest version of this publication can be found on our Website www adamequipment com O Adam Equipment Company 2009
13. pressed Improper calibration of the scale Damaged load cell Damaged Electronics Err6 A D count is not correct when Platform is not installed turning the scale on Load cell is damaged Electronics is damaged 5 0 CALIBRATION The scales are sealed to prevent unauthorised calibration Contact Adam Equipment or your supplier for more details Adam Equipment Company 2009 6 6 0 SPECIFICATIONS AZextra AZextra AZextra AZextra AZextra AZextra AZextra AZextra 3 6 15 30 3P 6P 15P 30P Maximum Capacity 3 kg 6 kg 15 kg 30 kg 3 kg 6 kg 15 kg 30 kg Readability 1g 29 59 109 1g 29 59 109 Tare 3 kg 6 kg 15 kg 30 kg 3 kg 6 kg 15 kg 30 kg Pan size 225 x 275 mm Operating 10 C to 40 C Temperature Battery life 90 hours typical Battery Life is less when the backlight is used Power Mains power supply to an internal transformer Interface RS 232 bi directional interface English German French Spanish selectable text Date Time Real Time Clock RTC To print date and time information Dates in year month day day month year or month day year formats Battery backed Display 3 x 6 digits backlit LCD displays Housing ABS Plastic with Stainless Steel Pan Overall Dimensions 315 x 355 x 110 mm 315 x 355 x 535 mm Net Weight 4 3 kg 4 7 kg NOTE AZextra P models have the Pillar Display O Adam Equipment Company 2009 7 0 SERVIC
14. s Zero to re zero the scale if small amounts of weight are shown when the platform is empty Taring Taring is used to eliminate the weight of a container so that only the net weight is displayed Zero the scale by pressing Zero if necessary The zero indicator will be on Place an empty container on the platform Press Tare to zero the scale The Net indicator will be on As product is added only the weight of the product will be shown When the product and container are removed the weight window will show a negative value If a different container is to be used remove this negative tare value by pressing the Tare once more Adam Equipment Company 2009 2 13 DETERMINING VALUE OF A PRODUCT BY WEIGHT To determine the cost of a product sold by weight it is necessary to enter the cost per kilogram or per 100g using the numeric keys or one of the preset PLU values Example Display will show Weight Unit Price Total Price in kg Place a container on the 0 000 0 00 0 00 scale and Press Tare Place the items on the 1 300 0 00 0 00 platform Key in the unit price 1 300 5 00 6 50 Press the kg 100g key to change the calculation to a price based on the cost per 100g or the cost per kilogram If a different unit price is required either press CE to reset the unit price to 0 00 or simply enter a new unit price Press the Auto Clear key will automatically clear the unit price when the last item
15. s supplier or Adam Equipment Company The company or its authorised Technician reserves the right to repair or replace the components at any of its workshops depending on the severity of the problems However any freight involved in sending the faulty units or parts to the service centre should be borne by the purchaser The warranty will cease to operate if the equipment is not returned in the original packaging and with correct documentation for a claim to be processed All claims are at the sole discretion of Adam Equipment This warranty does not cover equipment where defects or poor performance is due to misuse accidental damage exposure to radioactive or corrosive materials negligence faulty installation unauthorised modifications or attempted repair or failure to observe the requirements and recommendations as given in this User Manual Repairs carried out under the warranty does not extend the warranty period Components removed during the warranty repairs become the company property The statutory right of the purchaser is not affected by this warranty The terms of this warranty is governed by the UK law For complete details on Warranty Information see the terms and conditions of sale available on our web site WEEE COMPLIANCE Sor ay Sealed Lead Acid ae Battery ER ap Must be recycled Properly Any Electrical or Electronic Equipment EEE component or assembly of parts intended to be incorporated into EEE
16. tform If an optional Pillar display is supplied install the pillar in the upright position into the socket at the rear of the scale by carefully pushing the cable inside the pillar rod Secure the pillar rod to the socket by using two M4 screws A black plastic cap is provided to seal the socket from the bottom to avoid damaging the cable Level the scale by adjusting the four feet There are three displays both on both front and back panels Optional user display on pillar Displays are for the Weight Unit Price and Total Price Turn the power ON using the switch located on the right side of the base The unit will display the software revision number in the Weight window and count down to zero while performing a self test When ready all three displays will show zero The scale has an internal rechargeable battery which will make the scale operate up to 90 hours when fully charged or less if the backlight is on When the battery needs charging the arrow above the low battery symbol under the Weight window will be on and the display will show LO bAt for a few seconds and every 2 minutes as a reminder turn off the scale and charge the battery for 12 hours to gain a full charge 1 2 ZEROING AND TARING Zeroing You can press the Zero key when the platform is empty to set the zero point The scale has an automatic re zeroing function to account for minor drifting or accumulation of material on the platform However you may need to pres