1. 82 752 DISTANC 695m Figure 2 11 2 4 Setup Press shift key to switch soft function key make showing F3 soft key SETUP As show in Figurel 2 Press the key to enter function setup interface As show in Figure2 12 function setup includes tow sub function one is setting system data and time another is loading default function Press 24 IDI User s manual TDR DS6130 ite keys or the F2 soft key V A to select one in the tow function CABLE TEST RANGE 150m COEFF 0 82 i DATE TIME i gt LOAD DEFAULT 752 DISTANC 136m ENTER _ EXIT Figure 2 12 1 Load default Recovering all the type s coefficient to the system default value After selecting press F1 ENTER to execute 2 Date Time Selecting DATE TIME to look about the 25 IDI User s manual TDR DS6130 present time Press F1 CHANGE to adjust time As show in Figure 2 13 press F2 V A at this time to select in editing time and date option Press a gt to select Month Date Year or Hour Minute Second press rd to change the value After re setting press F1 ENTER to confirm CABLE TEST RESET RANGE 150m COEFF 9 82 DATE 07 05 2002 TIME 03 02 22 752 DISTAXC 136m ENTER Cw EXIT Figure 2 13 26 IDI User s manual TDR DS6130 2 5 Others 1 Background light Power on the background light turns on automatically 4 minutes without any key pressed the background light turn off automaticall
2. 10m measuring range 1 Press F1 to switch zoom function Zoom in the figure 2 3 press Fl to enter zoom state As shown in Figure 2 4 soft key F1 change to SHRNK CABLE TEST 2 STEP RANGE 900m COEFF 9 82 752 DISTAHC 691m SETUP Figure2 4 13 IDI User s manual TDR DS6130 The function can zoom the constrictive point near by the dashed mark and move to the center position of screen top right corner is the series different measuring range has different zoom series Press 4 to zoom in gradually As shown in Figure2 5 press it to zoom out similarly Adjust al keys to move the mark it will locate the failure points accurately 752 DIS TANC 692m SHENK FILE SETUP Figure2 5 14 IDI User s manual TDR DS6130 Zoom in the zoom state press F1 to renew the original location status Figure 2 3 2 Press 25 gt moving mark Press 7 can change the dashed mark position at the same time the distance of mark position will show on the right bottom of screen Attention 1 The highest input voltage of probe is 60V 2 It is valid that the measure cable placed in front of amplifier and divider 3 Red probe connects the coaxial cable s central line black probe to the shield line of outside screen Insures connection tightness otherwise influences the measure result IDI User s manual TDR DS6130 2 1 Manual Detection of Cable Fault Before measuring user shoul
3. 2 750 DISTANC 138m C Enter C__ Figure 2 1 10 IDI User s manual TDR DS6130 Presses the F3 COEFF key pop the type and coefficient setup interface As shown in Figure2 2 press lt A gt to select the cable type F2 to confirm CABLE TEST SCAN TYPE SYWU 75 5 G6 T 752 DISTANC 130m C ENTER __ Figure2 2 Presses Automatic Measuring the system will scan in turn base on 5 measure range from large to small in certain range If finds the failure point the system will select the suited range and put the mark automatically As shown in Figure 2 3 system 11 IDI User s manual TDR DS6130 stops scanning at this moment CABLE TEST SCAN RANGE 200m COEFF 0 82 752 DISTANC 695m Figure2 3 Illustration Judgment of locus states A rising reflection denotes open circuit Hi impedance serial or the cable have higher characteristic impedance change A falling reflection denotes short circuit T connection or the cable have lower characteristic impedance change Open circuit and short circuit have more reflection when the badness connection or other slight disconnection it has less reflection 12 IDI User s manual TDR DS6130 If there no reflection may be the cable hasn t failure point or the failure position has overstep the current measuring range the automatic measuring minimum distance is 8m if want to measure 5 7m please using manual measurement select the
4. AN RANGE 150m COEFF 0 82 752 DISTAHC 139m COEFF Figure 1 1 1 FI1 F2 F3 Keys Corresponding function of the LCD shows soft keys As Measuring Range Impedance Coefficient IDI User s manual TDR DS6130 2 Automatic Measurement The instrument can search the failure points automatically in fixed measuring range 150m 1600m and display it on the LCD as locus formats at the same time the mark will located the failure distance automatically 3 Shift Shift the Fl F2 F3 function keys on the LCD As shown in Figure1 2 CABLE TEST SCAN RANGE 150m COEFF 9 82 752 DISTANC 139m LOCAT SETUP Figure 1 2 IDI User s manual TDR DS6130 4 Select Changes the position of disable mark and enable mark 5 a gt Keys Presses the 25 key to move the position of mark 6 it tt Keys Changes the parameter value such as the Measuring Range Impedance and Coefficient etc Attention Power on enter the main interface As shown in Figurel 1 1 2 and press the ir keys to adjust the contrast of LCD IDI User s manual TDR DS6130 2 Operation Method of DS6130 2 0 Automatic Detection for Cable Fault Firstly connects measuring probe and cable for testing then turns on presses the soft key F2 showing in Figurel 1 pops the impedance setup interface As shown in Figure2 1 presses id to select the corresponding value with cable F2 to confirm CABLE TEST SCAN RANGE 150m COEFF 0 8
5. IDI User s manual TDR DS6130 DS6130 Coaxial Cable Fault Locator TDR User s Manual Ver 1 0 Tianjin Deviser Electronics Instrument Co LTD No 40 Yibin Road Nankai District Tianjin 300113 Tel 86 22 2768 2088 86 22 27645003 EXT 803 Fax 86 22 27645002 Email overseasbiz deviser com cn Website www devisertek com IDI User s manual TDR DS6130 Warranty The warranty period for this instrument is 18 months after it is sold The manufacturer or the agent is responsible for the necessary commissioning and testing Generally speaking during the warranty period Deviser is responsible for all the repairs free of charge unless the breakdown is caused by the improper usage The customer shall pay for the transportation cost and insurance cost for sending the product to the repair department while the costs of sending the repaired products to the customer shall be borne by Deviser or the appointed repair agent After the software and hardware provided by our company for this product is properly installed on the instrument the instrument will carry out its programming instructions However our company does not guarantee that various operations on this instrument will not be interrupted or no error message appears The warranty is only limited to the instrument and no warranty provided for the loss caused by the IDI User s manual TDR DS6130 breakdown of other equipment loss of life or loss of assets due
6. ble of Content 1 General Introduction of DS6130 1 1 0 Brief Introduction ccceeeeeeee cee ee eee 1 1 1 Familiar the Equipment oaeee 2 2 Operation Method of DS6130 5 2 0 Automatic Detection of Cable 0 0 00 5 2 1 Manual Detection of Cable 0 0 12 2 2 Accession and Calibration of User s Cable TYPOS unesene ee i a r E n 16 23 Filson n i iie aa EEE 18 2 4 SQUP EEE E E 21 PAEKO e e EE E T 24 3 Technical Specification 0c eee sees 25 IDI User s manual TDR DS6130 1 General Introduction of DS6130 1 0 Brief Introduction DS6130 applies the advanced TDR measuring technique it can display the cable failure using locus format on the LCD and locate the distance of the failure points It can be used in failure locating and dimensional measuring Characteristic as 1 Displays all the drawing and character on larger LCD shows various measurement details clearly 2 The functions of files saving and printing convenient for the user to manage the data and history inquiring 3 Unique zoom in out functions can locate the failure points precisely IDI User s manual TDR DS6130 1 1 Familiar the Equipment Power on emission pulse locus and parameter status will display on the LCD As shown in Figurel 1 the parameter is using the display last power off the default range is 150m impedance is 75Q as power on CABLE TEST SC
7. change to the next range If the reflection does not occur in all range it is means that the cable has not failure point 6 The 10m range is being set for about 5m to 10m failure points Due to the distance between emission pulse and failure reflection pulse is too approach please do not use the location function If the measuring distance is larger than 10m it is better to change to the next range 18 IDI User s manual TDR DS6130 2 2 Accession and Calibration of user s cable type User can calibrate the system based on the cable using condition 1 Connects the measuring probe and 100m standard cable open circuit in end according to the manual test method in 2 2 section sets the RANGE to 150m then moves the mark or presses LOCAT to locate the failure points 2 Presses F3 COEFF key to pop the wave speed setting interface As show in Figure2 2 press lt I gt to select the user cable type for calibration 3 Presses T to change coefficient the distance will be changed along with changing coefficient after adjust the cable to 100m presses 19 IDI User s manual TDR DS6130 F2 ENTER key to finish the calibration The coefficient is 0 5 0 99 Attention 1 Please unconnected such any equipment such as divider amplifier connector etc Otherwise the injustice will occur 2 Don t change the coefficient without calibrating the cable otherwise it will influence the measuring accura
8. cy if user change the coefficient unconsciously please using SETUP function to restore the default value out of factory 20 IDI User s manual TDR DS6130 2 3 File This function is used to save present measuring image Press Shift key to switch soft function key make F2 key showing FILE As show in Figure 1 2 press this key to enter the file system interface The system can save 6 files aggregately As show in Figure2 8 2 9 04724702 17 15 FILE2 04725702 08 43 FILES FILE4 FILES EXIT Figure 2 8 21 IDI User s manual TDR DS6130 lt FILE LIST gt HAME DATE TIME FILE 4 24 02 17 18 FILE1 FILE2 4 25 02 08 43 FILES FILE4 FILES C arr Figure 2 9 1 Save Press soft key SAVE to save the interface before entering file function the new file will overwrite the old one if there are files in system 2 Load Just as show in Figure 2 8 press soft key F2 LOAD to enter the load interface As show in Figure2 10 There are two functions one is print and another is delete function 22 User s manual TDR DS6130 CABLE TEST LOAD 752 DISTANC 695m Figure 2 10 1 Print connects EPSON LQ300K _ printer passing the serial cable in the accessories then presses F2 PRINT to print current interface As show in Figure2 11 2 Del delete the loaded files if the file is deleted it does not restore 23 IDI User s manual TDR DS6130 CABLE TEST RANGE 900m COEFF 0
9. d set the impedance and type just as automatic measurement manual searching failure point by pressing RANGE LOCAT A5 keys 1 In Figurel 1 press soft key Fl pop the measuring range setup interface As show in Figure 2 6 press rt or o gt to select measuring range you need The measuring rang divided into 10m 150m 450m 900m 1200m 1600m Press F2 key thus system will scan and measure in the measuring range user sets CABLE TEST SCAN RANGE 150m COEFF 0 82 752 DISTAHC 136m C ENTER __ Figure 2 6 16 Di User s manual TDR DS6130 2 Seeing the failure points on the screen user can press lt a gt to move the enable mark to the right edge of failure points read out the failure point distance Annotate user should fix the disable mark to the left edge of emission pulse 3 Presses Shift key to switch function key makes F1 soft key showing LOCAT As show in Figure 2 7 Presses LOCAT key system will locate the mark to the failure points automatically system will stop scanning at this moment CABLE TEST SCAN RANGE 150m COEFF 9 82 752 DISTAHC 139m LOCAT SETUP Figure 2 7 17 IDI User s manual TDR DS6130 4 User can press gt gt to move mark also can use the zoom function of automatic measuring method to locate accurately in last section 5 If the reflection doesn t occur in present range may be the failure points position have overstep the measuring range please
10. to the improper use of this instrument Warranty Limitations Our company does not provide warranty for the improper usage or insufficient maintenance including the software or connections added by the customer as well as user disassembling the machine without authorization During 18 months warranty period calibration service maintenance service and consulting service are free of charge Proper charges for material or maintenance amp repair service will apply after 18 months warranty period Following items are not in the scope of warranty 1 The battery and battery charger presented as gifts upon machine purchase 2 The distortion and damage of the panel the switches the devices and the outside cover of the machine caused by the mechanical external force crash fall etc as well as the resulting breakdowns of the internal components 3 Disassemble the instrument attempting to repair without authorization IDI User s manual TDR DS6130 Attentions The internal capacitors may still be electrically charged after the instrument is powered off The technical specifications and operation methods as stated in this user manual might be changed without prior notice If any further information is needed after using the instrument for a while please consult with the manufacturer All the copyrights are reserved No copy modification or translation without prior consents in written IDI User s manual TDR DS6130 Ta
11. y the instrument works in energy saving model If have any key respond background light will turn on again 2 Battery voltage inspection System working it inspects the batteries voltage ceaselessly When batteries voltage is too low the LOW will wink continuously it is time to charge the instrument and otherwise the instrument will shut down soon 3 LCD Contrast 27 IDI User s manual TDR DS6130 In the main display As show in Figurel 1 1 2 press T to adjust LCD contrast 3 Technical Specification Measuring objects 50Q or 75Qcoaxial cable Spec 8 type s factory style SYWV 75 5 G T SYWV Y 75 7Z GT SYWV 75 5S G T SYWY 75 9 T L SYWV 75 5Z G T SYWY 75 9BZ TL SYWV Y 75 7 GT SYWY 75 12 T L With 8 type user added 28 IDI User s manual TDR DS6130 Measuring range and precision Measuring range 5m 1600m Measure precision 1 of current measuring range Resolution Less than 1 of current measuring range Others Figuration size 190mmx80mmx152mm Gross weight 600g Working temperature 10 C 50 C Storage temperature 20 C 70 C Display 128x128LCD With back light power source Battery 7 2V 1 8AH Ni MH batteries Charger AC 90V 240V 50 60Hz DC 9V 0 7A Working time average 7 8 hours Full charge Charge time More than 12 hours 29 IDI User s manual Accessory Portable bag Special charger Measure probe specifications 30 TDR DS6130