Home

USER MANUAL - Golden Dragon Eye

image

Contents

1. i i Sete Liege Ot Poe Iia SET OMOFFHESET pinis Oe oe a j CHET BP TSTATHIG Sewer Boer a a Pl Hodel UIS 315 MSNswitch Model IS 41 Fig 3 MSNswitch UIS 311 UIS 315 amp UIS 323x setup for remote control via MSN messenger or thru Web User Interface 1 4 LED Indicators Explained LED Status Indicators for Model UIS 311 amp UIS 315 System is currently in Protect Mode only after pressing the UIS button If there is a disconnection the unit will reset Do make sure internet is accessible before activating this feature OFF No internet connection Blinking Internet is online Fig 4 UIS 311 amp UIS315 LED Indicator ON LED Status Indicators for Model UIS 322x LED LED status Condition description Green ON Internet connection available and UIS mode has been activated ae There is internet connection UIS mode button has not Green Blinking l been activated Green OFF There is no internet connection Fig 5 UIS 322x LED Indicator UlS usermanual SS A Chapter 1 Introduction Light indicators on LAN Port Light color Condition description G When On Internet speed is at 100M reen l a np When flashing Data transmitting receiving Yellow On Internet correspond speed is 10M Flash Data transmitting receiving Fig 6 LAN LED Indicators One fired amp Tao 0 Grean PORE cal TREES Power Oni with Surge Protector Indiceabor i Red iniri Conmeac
2. TCF aww ask com None Enable Disable upP OTCP lwww skype com Assign User can select to assign both outlets to check the 1 four sites or only one outlet or have both outlets checking different sites Status User can include Enable or exclude Disable a particular website from the check list Protocol MSNswitch can use either a ping UDP protocol or a web request TCP protocol format to check if a particular site is responding Website IP Address Enter reliable trusted websites to target MSNswitch will check how long it takes the site to respond Note The target site can be a Domain Name IP address or even LAN IP address For instance the Router s IP li Time out Settings T 3 a if 1 i fe T 7 x Set time out for each Website IP Address 3 second s Number of continuous time outs before outlets reset 3 pe Set time out for each Website IP Address The target site must respond within this time Else it is considered a time out Default is set to 3 seconds Note A larger time out will allow for instances of delay or lag from target sites Number of continuous time outs before outlet s reset Refers to the number of times all target site time out before MSNswitch resets Default is set to 2 sets UIS user manual 18 Chapter 4 UIS Web User Interface Outlet Setup Outlet Setup Outlet 1 Name Outlett Outlet 2 Name Outlet2 Auto reset outlet s every 0
3. OK Step 3 Enter MSNswitch main menu UIS user manual 11 Chapter 3 Software amp Web Setup 3 3 How to Access MSNswitch from WAN using DDNS The MSNswitch Web User Interface Web Ul above can be access remotely from Wide Area Network WAN Todo so i Setup port forwarding at your router a Login to your router setup configuration page b Goto Port Forwarding Virtual server section and open allow WAN Port 80 Type Protocol TCP and li Setup a Domain Name for your Dynamic WAN IP User can choose to either a Use the free pre assigned domain name a Each MSNswitch assigned a unique domain name as lt serial number gt iCV99 net b Rename this by browsing to http MSNswitch System Status Network Status Free Domain Name click to rename OR b Use 3rd Party free DDNS providers Todo so a Browse to these 3 party free DDNS provider website 3322 org dhs org DynDNS Dynamic DynDNS Custom myDDNS Zive org b Create a new user account and password Register a Domain Name for your current Dynamic WAN IP d Browse to http MSNswitch Configuration Network Dynamic DNS Select the service provider enter the registered domain name user account password Click Apply CEC OG GC O MSNswitch is now accessible from remote using the newly registered Domain Name For a description of Network Dynamic DNS functions see section 4 2 3 part v below
4. Support IE or Java Enabled Web Browser 4 Network Protocol HTTP TCP IP UDP SMTP Dynamic DNS DNS Client SNTP DHCP SNMP 5 Operating Temperature 0 C 60 C Operating Humidity 10 90 6 For indoor use only UIS user manual 1 Chapter 1 Introduction 1 2 Hardware Specification Model No UIS 311 UIS 315 UIS 322 UIS 323 Socket type 3x Schuko socket 3x North American 2x of either 2x of either Certification Electrical Rating Surge Energy Joule Rating Clamping Voltage Max Peak Spike Current Surge Protect Indicator Surge Protection Failure Breaker Available Sockets Internet Control able Power ON OFF switch Power Indicator Reset to Factory Default Internet Indicator Web Server CPU Supported browser Supported Network Protocols Network Access Operating Environment Package Shuttered Type F CEE 7 4 CE LVD RoHS compliant Input 250V 50 60Hz Output 10A 2500W total for 3 sockets 918J 775V 12 000Amps Yes Surge amp Auto Power Shut Down 10A reset able 2x fixed 1x swivel 2x fixed socket Type B NEMA 5 15R FCC Input 125 250V Output 10A 1250W total for 3 sockets 540J 400V 12 000Amps Yes Surge amp Auto Power Shut Down 10A reset able 1x fixed 2x swivel 2x swivel socket a Universal socket b USA Type B NEMA 5 15R c UK w o shutter Type G BS1368 MS589 SS145 d AUST China Ty
5. Tecelve UISbot i Available Steven says PF 05 21 gt SET OFF OQ Wisbot says FF 05 21 Done Steven says PF 05 22 a SET ONG UlSbot says FF 05 22 ra Done M H 4 UISbOt Available Steven says FF 05 17 a GET IF UiSbot says F 05 18 lee gt fi WAN IP 122 116 89 170 IP 1927 168 0 166 UISBOT Available Steven says PF 03 47 GET STATUS UiSbot says F 03 47 Current Connection Status www google com 30 ms Www yahoo com 160 ms www youtube com 20 ms Outlet Status F Outleti ON Outlet2 ON 14 Chapter 4 UIS Web User Interface Chapter 4 MSNswitch Web User Interface 4 1 Information The Information tab contains the following subsections 4 1 1 Current Status 4 1 2 System Status 4 1 1 Current Status This section displays the current status of the outlets gt blip ft92 108 0 0 50 o Windows Interne Explorers Alia Gis lE 132 143 150 it x a we Qa Faerie g pa yd Se EO o mp Gee Sates Tote Ge a re oe MSN SH Chi CCC eee Target Site IF Adios R sanes Time WAW Goog ae Com M4125 139 105 19 ma Conkiguraian f 7 wa yahoo com 230749 idi me Tay wa en Bing eam 209 69 113 96 a ms CURE AE sahis nii Syston Status j YANE gs com 0 8 119 127 i ms Configuration ew Skype COM be wee 13 4i ms Sicled ule Hetwart E mal Sreaunt Stas and Comal Th tl Fre Item Gal Canna System Time US
6. 3 4 How to Access MSNswitch from WAN using Instant Messaging Tool MSNswitch supports Instant Messaging Tools like MSN Messenger Yahoo ICQ etc will be available in future firmware Once setup you can get notifications and issue commands to check the status as well as turn on off power or power cycle certain ports using MSN Messenger and like tools UIS user manual 12 Chapter 3 Software amp Web Setup 3 4 1 How to Setup Instant Messaging for MSNswitch Step 1 From PC run MSN Messenger or goto htip www MSN com to create a new Windows Live ID or account An ID or account will have to be created for each MSNswitch device Remember the user name and password Step 2 Browse to http MSNswitch Configuration MSN Select Online and enter the new MSN account User Name password Contact Account and click Apply Contact Account refers to your own MSN account whoever wants to control MSNswitch Step 3 Allow a few moments for MSNswitch to connect and Sign in The connection status will be shown on the heading Step 4 Once connected those users listed in Contact Account will receive a notification to add MSNswitch as friend Once added you can control MSNswitch by chatting with it Status Account Online has just signed in Options Note Only the users listed in Contact Account can command MSNswitch f you are removed f
7. MSNSWITCH WEB USER INTERFACE sccccssscccssscccsscccssscccsssccsssscessses LO GU Ua E ORM ATON o asa a al teas css eadacteson E ttl tines merase ioe cece 15 ANAM REUSING SaS ea atcha apsteteacanta int etvamauantestpansainen atom wuiano aise doouaihe lala ian en dua esiatouaneuionsuoamnlans 15 AND 75 She Ws SAL eed enone ash E E S A E E E E E EA 16 Aye CONFIGURATION apii A ENE S A AEEA OA E die eas 17 WA SOCOM GUT AN OM ee E A A AA SS 17 ADD ASCACAUIC EE E ENEE E E E EO EN E A 20 DO EWO KE reran r E E E T TO O O E O O NA 20 AD Ae E 1 a OE EE E E E E AEE E OTE ETE EE A O E O E ONE ON EE 24 AD DT MO COUMU e e a AA AE a E a a E T Ou ot Doh ooh Ohta e 23 AD Or MS Neessen na E EA 26 a E E E a A Mie E E E EEEE EEE EAE 28 BA E E lO E E A A A A EE E E A E E E E E E T E 29 AS TOG INFORMATION ona n E 30 WM Eyen MOG icoriceteiaia dec Ea A A E E cnn att oa tadas 30 E E eae E T E ee eee E E ees R EN E E E T cree eee ee 30 AAs Abo eea E A eae 30 APPENDIX A ROUTER CONFIGURATION sssssssssseeeeecessossssssssssssssesescssssssssssssssssesessssssssssssssss OD APPENDIX B IP ADDRESS SUBNET AND GATEWAY ccsccccsssssccccccccccscssssccceeseeessees OD APPENDIX C GLOSSARY dossiere peenaa aaa oaaae aeaa oaeaeei aa aaa oeeaaeaii OF Chapter 1 Introduction Chapter 1 Introduction 1 1 Introduction MSNswitch is designed to automatically power cycle either one or both of its outlets when either a inte
8. is to set the language interface FS hipoi FA LEOAS Windows Internet Explorer IBE Ga R 132 166151 E ps dip Fewkes hrpi 180 0 1809 Te g O ee Bee a e D MSNswitch p EHH a iniennebon Shia sm D Intertane Mail Engish English DO Chinese MTraditionall Cr Chinian Traditional 5 Chre amplified Chinese Sirpa D Spaneh Spanosh D Portuguese razia C Polija Brazilian O Hain Halen Note Seting peferences vel not work Hou hma disebled cookies wn your brewer UIS user manual 29 Chapter 4 UIS Web User Interface i Language Choose the language for the Web UI and e mails 4 3 Log Information This section will log events and categorize it into three types a All if there is a time out or target site IP address is not resolvable b Status refers to events such as Outlets turning On or Off Manual Off refers to when the outlet is turned off manually Auto Off refers to when outlets are turned off on schedule or by the system c Notification when the system restarts or fails to connect to time servers 4 3 1 Event Log S hiipi TA O01 SOF Windows Inter Explorer G i E L J A ki ca Feme haai MSNswitch n iniemmebon f ET i E Even Lag Type F Cunen Mais Syshami Shale Conk e Ferny y e ph Caste Tims ype Evert Centurion JSE 16 56 30 Strats WWE On Schedule DH AMSM6 16 5255 Etats Qute Manual On Hetek a1 Wb 1G 1082 7 Status Carlet bs
9. minute s Delay before checking VWebsite IP Address after i mnia power reset P Pa Outlet power reset delay E noe Power on delay between Outlet 1 and Outlet 2 40 l second s Outlet 1 Name Outlet 2 Name Name the outlet in order to identify the connected device This also allows ease of reference when using MSN or setting schedules Auto reset outlet s every MSNswitch will reset the outlets every xx minutes Choose a figure between 1 to 1440 minutes Default is 0 disabled Note 1 Only the Outlet that is originally ON will be reset If the outlet is OFF it will not reset Turn it ON OFF at Information Current Status 2 Power to both Outlets 1 amp 2 will turn Off and then On subject to any Power on delay between Outlet 1 and Outlet 2 settings Delay before checking Website IP Address after power reset This section determines if the outlet will reset once or twice WHEN target Website IP Address is no longer responding If this is set to O default upon Website IP Address failing MSNswitch will reset its outlets once It will now wait until the target Website IP address responds before restarting the check lf this is set between 1 and 30 minutes eg 5min then upon Website IP Address failing MSNswitch will reset its outlets 1 time It will then wait 5min and checks if the target Website IP address is responding If not it will reset its outlets 2 time It will now wait until the targ
10. to your PC The text file will have a default format of ScheduleYYYYMMDD cfg Restore Settings or Schedule Use this function to restore a cfg configuration that has been saved earlier Click Browse to the location of the file and click Restore Reset to factory default This function will reset all settings to its default value UIS user manual 31 Appendix A Router Configuration Appendix A Router Configuration The following section describes the initial configuration of the router and port forwarding for your router If your router is not listed here please refer to the manufacturers website for assistance with configuring your router to work with MSNswitch Port Forwarding for MSNswitch MSNswitch requires certain ports to be open on your router to allow other computers on the Internet to view it on your internal network Normally your router will have the less common ports disabled or blocked by the router s built in firewall In order for MSNswitch applications to work properly and not be blocked the firewall settings need to be configured In each instance there will be a trigger port and incoming port s where traffic on the trigger port tells the Firewall to open the incoming ports MSNswitch require that TCP Port 80 default settings be opened to the Internet TCP Port 80 is used for accessing the MSNswitch homepage If your Internet service Provider blocks port 80 9001 you ll need to reconfigure your came
11. Function Language uini Catz Da oal Reret Click on the icon to turn Click on the icon to the Outlet On or Off Reset the Outlet i io Fig 10 Current Status page i Connect Status Target Site This is the default target site as listed under Configuration IP Address The IP address of the Target Site Response Time based on UDP TCP protocol sets in Configuration page Timeout number of timeouts as a percentage of total tries since reset Q Note This page will auto refresh every 5 seconds li Status and Control This section shows the current status of the UIS Function and Outlet User can click to control the Outlets or UIS function from here Note For models UIS 315 and UIS 311 the U S Function can not be controlled via Q the web user interface UIS user manual 15 Chapter 4 UIS Web User Interface Icon Description The UIS Function is Off MSNswitch will not perform outlet reset when connection loss is detected The UIS Function is On MSNswitch will perform outlet reset when connection loss is detected The Outlet is Off The Outlet is On The Outlet is On and U S Function is Off 4 1 2 System Status This webpage displays System Status Information A Rp 18 0 9 S00 Windows Internet Explorer Aili Gas E 132 143 0150 w iy x hy B pr Peada hipin aa oasa i 8 T i fear iie Toles i pe 5 Ls _MSNswitch Ms lle informatica L Tish Cunent Stato Haldwere Wargo masaj Sy sherri
12. MSNswitch Auto Restart Crashed Network Device USER MANUAL For models UIS 315 UIS 322x Version 014 1516 2 40 MNS 1214 CONTENTS CHAPTER 1 INTRODUCTION sacanear A ke INTRODUC ON a A AA E A A 1 Ize HARDWARE SPECIFIC ATION miraire E EAER AEN EEE NONE AR A E NAA aaa 2 I3 NETWORK DIAGRAM cra arira EE E AAEE EAEE NOAE ARE A E NAA EA Ai 3 4 LED INDICATORS EXPLAINED easicncacccseccnceaiasencnns cians EET NONE EAE O AE OA A O ONRAN 4 CHAPTER 2 HARDWARE SETUP secscsssssnsessoasscesseneseccaconddassccesoustecesssssssedccssasesdecsoswanessesessecsesesese CHAPTER 3 SOFTWARE amp WEB SETUP wes ssccscscsssstsdsssesiacscsosteanecoesssnesssecsoaseccecnsennseeessossessesess LO Fl UINTERODUCTION raira a A Gee a ee 10 3 2 HOW TO LOCATE amp ACCESS MSNSWITCH IN LAN sesscsccctsntcetcenennscescnsoascesceneanesrsonseaes 10 3 2 1 Locate MSNswitch in LAN using the default hostname o on 10 3 2 2 Locate MSNswitch in LAN using Netility program c ccccccccceeccceecceesccaeeecaeecaeeseaeeeaeeeeas ll 3 3 HOW TO ACCESS MSNSWITCH FROM WAN USING DDNS 1 0 eeeeeeeeeeeeececeeeeeeeeeeeaeeeeeeenaeees 12 3 4 HOW TO ACCESS MSNSWITCH FROM WAN USING INSTANT MESSAGING TOOL 0008 12 3 4 1 How to Setup Instant Messaging for MSNSWItCHN ccccccccecccnecccneccnesccasscueceaeeseueeeaeeeeas 13 3 4 2 How to Control MSNswitch using Instant Messaging ccccccccecccaecccaecceeccaeseueeeaeeeees 14 CHAPTER 4
13. Time Tee 16 WT Se 15 oye Siom tP Ferran versinn 240 MHS 1244 UES Jasi meat o Conky 7a Sene Humber Ja25966151 Sarriega a plime gisi Configuration road ie Hid maivh E mail AAN tiean rere Hosters FASHeratch Primar ONS Serer 1 9511 al IP Sddan 192 16 g 160 Secondary CS Sera 18 96 1821 Ceteuli Gabana 192 169 01 Tira Server fore rast rs MEC Adiesa 00 03 E4 015E 07 Fraa Corin Hara icheck ta rane 2505959 1541 sete nal Seabee Tiia i System Information This section shows general hardware information such as the Hardware and Firmware Version the serial number Uptime System Time and when the system last reset li Network Status This section shows all information relating to Network environment Hostname This is the default hostname User can rename this by browsing to Configuration Network page UIS user manual 16 Chapter 4 UIS Web User Interface Free Domain Name By default each unit is assigned a Free Domain Name The domain name is assigned as lt serial_number gt iCV99 net The DDNS server site is located at DDNS iCV99 net Select Click to Rename will redirect user to http ddns iCV99 net where user can register an alternate name Note Other than Domain Name user will also need to do Port Forwarding in order to view the Web UI from remote See how to do Port Forwarding in Appendix A 4 2 Configuration The following option allows the user to configure the MSNswitch 4 2 1 Configu
14. and be accessible from the internet Dell http www dell com TrueMobile 2300 Wireless Broadband Router 1 Log into your router using your router IP 2 On the main page click on Advanced Settings at the top of the page 3 Go to the Port Forwarding section and select Custom Port Forwarding Settings 4 Check the Enable box 5 Enter the desired name or description in the Service Name field such as MSNswitch Web 6 In the Incoming Ports field specify port 80 in both boxes 7 In the Destination IP Address field enter MSNswitch LAN IP address 8 In the Destination MAC Address field enter MSNswitch MAC address You can find the camera s MAC address by either looking at the MAC address sticker on the bottom of the camera or by utilizing setup utility to display the MAC address Microsoft http www microsoft com hardware broadbandnetworking MN 100 Wired Base Station MN 500 Wireless Base Station 1 Log into your router using your router IP UIS user manual 33 Appendix A Router Configuration 2 Open the Bass Station Management Tool and then click Security 3 On the Security menu click Port Forwarding and then click Set up persistent port forwarding 4 In the Enable checkbox check in the checkbox 5 In the Description box type a description of the server field such as MSNswitch Web 6 In the Inbound port boxes type in 80 80 i e from Port 80 to Port 80 7 In the Type box selec
15. ate Internet Protection The Internet LED will now stop blinking and stay on See LED indicator for reference Note Press UIS on off button only when Internet LED is blinking Pressing the button when Internet LED is OFF results in continuous resetting UIS user manual 7 Chapter 2 Hardware Setup The following details the hardware installation procedure for UIS 311 Step 1 Connect the plug to the main power outlet The Green LED will light up Step 2 Connect the power plug to the MSNswitch power output port Note In order for MSNswitch to maintain continuous internet connection or reset your xDSL modem Router the router power input must be connected here Step 3 Connect MSNswitch LAN port to your router The Internet LED light will blink to show that the internet connection is ready Step 4 Press the UIS on off button to activate Internet Protection The Internet LED will now stop blinking and stay on See LED indicator for reference Note Press UIS on off button only when Internet LED is blinking Pressing the button when Internet LED is OFF results in continuous resetting UIS user manual 8 Chapter 2 Hardware Setup The following details the hardware installation procedure for UIS 322x Step 1 Connect the power cord to device and wall outlet The two orange LED will light up indicating that the Outlet is ON Press the Orange LED for 2 se
16. conds to turn the Outlet On Off Step 2 Connect the power plug to MSNswitch outlet Note In order for MSNswitch to maintain continuous internet connection or reset your xDSL modem Router the router power input must be connected here Step 3 Connect LAN cable from your router Step 4 Make sure the Internet LED light will blink to show that the internet connection is ready Press and hold 2 seconds UIS On Off button to activate internet protection UIS user manual 9 Chapter 3 Software amp Web Setup Chapter 3 Software amp Web Setup 3 1 Introduction MSNswitch is designed to work without having to install any software see hardware setup above However for advanced user the unit can be customized and configured for remote access This gives the user further control over the power ports There are two ways to remotely control the outlets access from WAN a Using DDNS and Port forwarding see Section 3 3 or b Using MSN instant messaging tool future version will include Yahoo or ICQ see Section 3 4 Note For models UIS 311 and UIS 315 only Outlets 1 and 2 can be remotely controlled The third outlet is fixed for local use only 3 2 Howto Locate amp Access MSNswitch in LAN MSNswitch comes with a built in Web User Interface Web Ul that allows for more advanced control over the unit There are two ways of accessing the Web UI in LAN i e both MSNswitch and the PC is connect
17. ding DDNS fields in MSNswitch Domain Name This is the Domain Name you have created from the above selected DDNS provider Name UIS user manual 23 Chapter 4 UIS Web User Interface This is the Login Account name that you have created with the selected DDNS provider Password Enter the Password you have assigned to your DDNS Account Use Public IP to update DDNS Choose Yes to ensure that MSNswitch uses the WAN Public IP to update the selected DDNS server 4 2 4 E mail This webpage allows user to have MSNswitch send all notification appearing in Event Logs to email accounts listed in the E mail Address Book S kiipi gz i480 N O Windows Internet Explorer Aliel ETS eB coe E18 sty dl his T Favia bt yf ea ay fe om Bees Satay Toe Ge ar Em ee MSN sw itc h et eae Cimer Taas System Status Err Naticaten E ra Sanm Erna Fart Configuration Sender s Erral Address Beta u E mail Server Requires Herk Ayiherdi gjin Liar Hame Password Sieben Titre Language Pent Log i E mail Settings Email Settings E mail Notification Enable v E mail Fort 25 Senders E mail Address E mail Server Requires Authentication No User Name a E mail Notification Select Enable or Disable default When enabled two additional section will appear The Test E mail section and E mail Address B
18. ed to the same router a by hostname entering hito MSNswiitch in the browser on the local PC or b by using the Netility program 3 2 1 Locate MSNswitch in LAN using the default hostname Step 1 Open a browser and type mra al calle http MSNswitch eee Hee Step 2 Ganon 192 9480 59 A password dialog box appears Tha naar Lk ee aer TE aed pee By default User name is admin SD Sets reer eth erat Password field is left blank paamverriba ea an rascurerurrer bade wttendcation Press OK UIS user manual 10 Chapter 3 Software amp Web Setup Step 3 Enter MSNswitch main menu Step 1 Download the _ Netility program from http www MSNswitch com or http www Megatec com tw and install Once installed Netility will locate and list the K HAE MSNswitch units Q Note 1 Netility can only discover MSNswitch units that are located within the same LAN or network 2 Netility will show LAN IP if units are connected to a Router Else user will have to manually assign an IP address Step 2 ammnctte 192 148 0 140 Click Launch Device to run Internet Explorer or your default browser and access the IP E address of the unit Tha anrvar 192 154 0 1 ak rape a uverrasre perad Weri Thee ae rpg a pie aT re paged be mrt ian ineecun rarer base mirer Rihuta aeon A password dialog box will appear By default User name admin Password field is left blank Press
19. et Website IP address responds before restarting the check Outlet power reset delay Set the Off gt On delay for the Outlet This applies to both outlets Power on delay between Outlet 1 and Outlet 2 Set the power on interval between Outlet 1 and Outlet 2 Set to O to disable this feature Default is set to 10 seconds Note This feature only works if BOTH Outlets are in the ON state when power resets If the Outlet is OFF it will not Reset UIS user manual 19 Chapter 4 UIS Web User Interface 4 2 2 Schedule This option allows the user to schedule the power on off reset for each of the two outlets Outlet 3 cannot be scheduled Ga i A A i x oy tap Peoi M bite y 1a2 1e4 0 150F Ei a T i gt Begs Safety Toles Gi a MSNswitch_s BEDEM iiome f zish a Ti ii O Ouled CCa Guir Action G On C On CARa E ea ATi Dae hayymmidd GE Sunday Monday Tuesday Wednesday Thiidayi Fiidey Saturday Ae ren E mnd Accaura Adi WSH Bystem Titre Configuration i New Schedule Event Outlet Select to schedule an event for either both Outlet 1 or Outlet 2 Outlet Action Select to either turn Outlet 1 or 2 On or Off Date yyyy mm dd Select to frequency of the event to be either a Once in which case the current date is automatically entered or b Reoccurring on a particular day or a daily event Time hh mm If it is either a reoccurring on a particular day or a daily event then en
20. gn up to 8 MSN user who can receive notification control AND receive MSNswitch feedback from their MSN account Once assigned the respective user must then add MSNswitch to their Contract list Failing to do so will result in user not being able to control MSNswitch Once added just type a random character and MSNswitch will respond with instructions Refer to section 3 4 2 above on how to use MSN Note If a MSN user has been removed from the Contact Account list The user will no longer be able to control MSNswitch via MSN However the user will still receive notification from MSNswitch 4 2 7 System Time This page allows the user to set the system time User can also set an All systems Auto Restart interval This reduce the possibility of hang or non responsive system hiipii TA O01 SOF Winder Inbena Explorer G Je E v gen aa Feme hooi MSNswitch n jinfonmeshiom k r Tithe Bebian Gubomatic Updatas 12 Hour Time Serva imari st ipa LIETE tera Time Joma GhTaj in fey Reate tam y T 01d 113e Shefkgurations fsiem Tome 01 bd 17 3862 Schedule Heteark E mail Argir i MSH ig Rasim System Even mre Sysinm Timo Ae Larguagi CEEE on o moina Event Ling Manually Rasiat thea By aiim a Fig 12 System Time Settings page i System Time i Sys tem lime Time Between Automatic Updates 12 Hours Time Server time nist gov ED Time Zone GMT 8 00 Relative to GMT Ap
21. ised of a network ID and a host ID The network ID identifies the logical network to which a particular device belongs The host ID identifies the particular device within the logical network IP addresses distinguish devices on an Internet from one another so that IP packets are properly transmitted IP addresses appear in dotted decimal rather than in binary notation Dotted decimal notation divides the 32 bit value into four 8 bit groups or octets and separates each octet with a period For example 199 217 132 1 is an IP address in dotted decimal notation To accommodate networks of different sizes the IP address has three divisions Classes A for large B for medium and C for small The difference among the network classes Is the number of octets reserved for the network ID and the number of octets reserved for the host ID Class Value of First Number of Octet Hosts 1 126 First octet Last three octets 16 387 064 B 128 191 First two octets Last two octets 64 516 192 223 First tree octets Last octet Any value between 0 and 255 is valid as a host ID octet except for those values the InterNIC reserves for other purposes 0 255 Subnet masking Loopback testing and interprocess communication on local devices 224 254 IGMP multicast and other special protocols UIS user manual 35 Appendix B IP Address Subnet and Gateway Subnetting and Subnet Masks Subnetting divides a network address into sub netw
22. ists in this layer MIB Management Information Base The database i e set of variables maintained by a gateway running SNMP Network Management Station OID Object Identifier The variables defined in a MIB Router A computer that manages traffic between different network segments or different network topologies It directs the destination IP address The network media can be different but the higher level protocols must be the same SNMP Simple Network Management Protocol A standard protocol used to monitor IP hosts networks and gateways SNMP defines a set of simple operations that can be performed on the OIDs of the MIBs managed by the monitored Agents It employs the UDP IP transport layer to move its object between the Agents and the NMS TCP IP Transmission Control Protocol Internet Protocol A protocol suite used by more than 15 million users with a UNIX association and widely used to link computers of different kinds UIS user manual 37
23. must be used in order to access MSNswitch web interface in LAN Note Changes here will result in a system reboot Ethernet UIS user manual 22 Chapter 4 UIS Web User Interface Connection Types Auto oense v Connection Type User can choose between 10M or 100Mbps or Full or Half duplex connection type This is generally left to Auto Sense for ease of management Q Note Changes here will result in a system reboot v Dynamic DNS Serice Provider teem Select an additional DONS provider Use this as back up to the free pre assigned Domain Name Domain Name Name Password i Use Public IP to update DDNS Yes Dynamic DNS DDNS allows the user to alias a dynamic IP address to a static hostname So no matter how many times your ISP changes the IP address you will be able to locate your unit over WAN Each MSNswitch is pre assigned with a free Domain Name at lt serial_ number gt iCV99 net Browse to ddns iCV99 net for information Apart from this user can opt to choose other 3 party free DDNS providers like 3322 0rg dhs org DynDNS Dynamic DynDNS Custom myDDNS Zive org MMMMM M In general to register a Domain Name with one of these sites a Go to the DDNS provider website listed above b Register a new user account and password with the DDNS provider c Choose a Domain Name to point to your current Dynamic IP d Enter information obtained in b and c into the correspon
24. nl On E mail SOT 1616 16s Statue Que Manuel OF AL Gout 20010107 B00 ge Noth ation Seve BOGS wai goue Com Can not be maake SO BOLH Notification Sarar adds wak yahi com cen not be nacked S101 H Notfic aban Sener addrasa waa bing com can not ba rasah NOVI O00 Taur iei Aug On giidina diid Taus Galei Ano On Fig 14 Individual Camera Configuration 4 4 Help 4 4 1 About The administrator can use this section to check firmware information save restore settings and see manufacturer s details UIS user manual 30 Chapter 4 UIS Web User Interface foe Aiha aTe U SUF Widnes tari tepara Go a7 E ipi ee ig Perens oe bite IS We By MSNs witch ia Informal Simien Curant ahs mojem Siatue Frame Version 7 40S 124 pS 1 atu Hardware Yarmi Masa Configuration Sanal Number 332503151 win ke Caonigurateon Scheie ae Fatwa eusan Stic Emmi z Account wne MEN ch Syalam Tre Scheie Langue Restore Settings w Schedule Raadi to factor defaut Rasat Hegoa Spam Technologies Ine Tal b 2 87 920 Poe 8 ST aes E mel US comm tiv brbtpe ewe megates com tw Rep Oy ES Th epee ah Fig 15 About page About This shows the Firmware Version Hardware Version and Serial Number li Save Restore Settings Settings Click Save to save the configuration to your PC The text file will have a default format of SettingsY YY YMMDD cfg Schedule Click Save to save your schedule information
25. ook section E mail Server UIS user manual 24 Chapter 4 UIS Web User Interface Only POPS servers are supported IMAP amp HTTP mail servers are not supported E mail Port Default to port 25 User can specify a different port if necessary Sender s E mail Address Enter the E mail address assigned by your e mail server E mail Server Requires Authentication Please check with your e mail server admin if this is required Test E mail ond a ies E mail ered How Send a test E mail Enter a valid e mail address to send the test email to E mail Settings E mail Address Book List the users who shall receive an e mail notification as they appear in the Event Log section 4 2 5 Account This webpage allows you to set an administrator password UIS user manual 25 Chapter 4 UIS Web User Interface Ff Mipaka 168 0 1307 Wiera Internet Epoa jml E r uF g 1P La 150 Traian at ip Faria We bito sivas en 0 15 i al renee Brets Tade u Em SOON swi teh n E iiti information Hiki Curai Stes 3 5 Password Continn Password System Statues Configuration CHE Schedule Pd eee E mail Aes deat HE ror System Tame Languiaga Evan Lag i Account Settings Recount uani i Lagin Passward Conhirm Password admin Login The administrator can set a name consisting up to 32 case sensitive characters By default the Administrator Name is set to admin no password set j
26. ork addresses to accommodate more than one physical network on a logical network For example A Class B company has 100 LANs Local Area Networks with 100 to 200 nodes on each LAN To classify the nodes by its LANs on one main network this company segments the network address into 100 sub network addresses If the Class B network address is 150 1 x x the address can be segmented further from 150 1 1 x through 150 1 100 x A subnet mask is a 32 bit value that distinguishes the network ID from the host ID for different sub networks on the same logical network Like IP addresses subnet masks consist of four octets in dotted decimal notation You can use subnet masks to route and filter the transmission of IP packets among your sub networks The value 255 is assigned to octets that belong to the network ID and the value 0 is assigned to octets that belong to the host ID For the example above if you want all the devices on the sub networks to receive each other s IP packets set the subnet mask to 255 255 0 0 If you want the devices on a single sub network only to receive IP packets from other devices on its own sub network set the subnet mask to 255 255 255 0 for the devices on the sub network Subnet Mask Routing and Filtering 0 0 0 0 IP packets are transmitted to all devices 255 0 0 0 IP packets are only transmitted to devices that are IP that s first octet matches the sender s IP address s first octet two octets ma
27. pe I AS NZS3112 CCC FCC a Schuko shuttered Type F CEE 7 4 7 17 b UK shuttered Type G BS1363 MS589 SS145 c French Type E CEE 7 5 d Danish Type K Section 107 2 D1 CE LVD RoHS Compliant Input 125 250V 50 60Hz Output 10A for 2 sockets amp DC5V 500mA for USB port n a n a n a n a n a 10A Thermal fuse 2x fixed 2x fixed socket n a Main power ON OFF Individual outlet power ON OFF LED button switch Press amp hold 2 seconds Green LED Green LED Orange LED n a n a Long press all 3 LED buttons Red LED Red LED Green LED 32 Bit RISC CPU IE and Java HTTP TCP IP UDP SMTP Dynamic we Client SNTP BOOTP DHCP FTP UIS user manual 10 100 Base T RJ45 Cat 5 0 C 60 C at 10 90 relative humidity For indoor use only White Color Box Chapter 1 Introduction 1 3 Network Diagram The following Network diagrams applies to all 3 models of UIS 311 UIS 315 and UIS 322x MSNswitch E bo Model monie g a S 35 WAN AN a a Dansa xDSL cable amp 3 5G modem ue LAN Local user Router Au Fig 1 MSNswitch UIS 311 UIS 315 amp UIS 322x setup to perform auto reset of router and modem H Server BB NAS iP Cam P LAN P M Power input Line LAN LAN Fig 2 MSNswitch UIS 311 UIS 315 and UIS 322x setup to keep internet device alive Chapter 1 Introduction
28. ply System Time 2010 03 22 18 19 06 yyyy mm dd hh mm ss Apply Time Between Automatic Updates The user can set an interval for time synchronization Select from either none 1 3 12 hours or 1 10 amp 30 days Time Server UIS user manual 28 Chapter 4 UIS Web User Interface Choose the nearest Time Server to your location The user can choose from the list of a maximum of 30 Time Servers To add a new Time Server click Edit delete an existing Time Servers from the list then the Add dialog box will appear Click Back to return to the System Time Settings webpage Time Zone Relative to GMT Select the appropriate time zone Click Apply to save changes System Time yyyy mm dd hh mm ss This section is to manually set MSNswitch System Time The format is pre determined to yyyy mm dd hh mm ss in 24hr format Click Apply to save the changes ii Auto Restart Auto Res tart 5 ystem Auto Restat System Every o minute s l 0 Disable Apply Manually Restart the Systems Fig 13 System Restart Auto Restart System every 0 Disabled Set the MSNswitch server to automatically restart after a preset interval This will reset the server The power supply to individual outlet is not disrupted during the server restart process Use this to guard against system freeze Manually restart the system Click Apply to manually restart the system immediately 4 2 8 Language Use this section
29. ra and router to other ports such as 81 9002 82 9003 etc To change the port settings on the camera you ll need to use Utility Below are some examples of setups you should refer to your Router s User manual or contact your router manufacturer for assistance in configuring the router D Link http www dlink com DI 604 DI 614 DI 624 1 Log into your router using your router IP 2 On the main page click on Advanced at the top of the page 3 On the left side of the page click on Virtual Server Note Make sure DMZ host is disabled If DMZ is enabled it will disable all Virtual Server entries 4 Enter the following information on the page Enable Disable Enabled Name MSNswitch Webpage Private IP Type in the UIS LAN IP address for example 192 168 0 5 Protocol Type TCP Private Port 80 Public Port 80 Schedule Always 5 Click Apply to save the settings MSNswitch should now be configured to work with your router and be accessible from the internet UIS user manual 32 Appendix A Router Configuration DI 704 704P 1 Log into your router using your router IP 2 On the main page click on Advanced at the top of the page 3 On the Virtual Server page enter the following information For ID 1 Service Port 80 Service IP Type in the MSNswitch IP address for example 192 168 0 5 Enabled Disabled Enabled 4 Save your settings MSNswitch should now be configured to work with your router
30. ration 4 2 2 Schedule 4 2 3 Network 4 2 4 E mail 4 2 5 Account 4 2 6 MSN 4 2 7 System Time 4 2 8 Language 4 2 1 Configuration Use this section to configure how MSNswitch checks websites Advance users can use this to customize MSNswitch to check network devices io Mp 1S as Amiras Inter nel tapie Sial x Gici F 13214 0150 te tq i a Poi A paia aaa h 8 Uo dh Bees Sete gt Toe Ge j Em O _MSNswitch_4 E ionat f BESIT Xa Tre Terp i are Pi 1 ae Zan Aasrign Syal Pranzo Webeme F Akira Shan sane 7 m a i ek muvee All if ie Ernabk Li Bisabla i LOA gt TSA Www ook gm Gonen on z ic T hogs k LD Eee L Disa hi w PE TCA Ww EID T i Enabia CI Dmabla LDP gt TEP ewe bang Conn Eraik O Dhabi OP TCP www ask com Contigua bit gt L Siheli Hotar tl Hiz D he ART E mai fing w Erabi U Dmabi e Op TEP WE BRE GAT Apcoutd HSH Sysiem Tire Shoe TEP wil gorda wah peje TAS y and LOP wil ping the Wotan F Addis Languacg Sea dinne aui for each Wiese iF Address a second s Humber ol continucus bime cuis before outes reset 19 UIS user manual 17 Chapter 4 UIS Web User Interface Website IP Address site i Assign Status Frotocol Website IP Address All a Enable Disable UDP OTCP www google com a Enable Disable UDP TCP A Enter reliable Enable Disable UDP OTcP iii mr ae sites to target Enable Disable UDP
31. rnet connectivity is lost resets Router Modem to restart it or b the network device being monitored is no longer responding in LAN It can also be used to a remotely control outlets via instant messaging tool like MSN or a Web User Interface b perform scheduled power on off reset Therefore MSNswitch is particularly useful where the internet connection and accessibility to a remote site is critical MSNswitch can be setup so that if the remote broadband cable DSL connection drops or if the remote router freeze up it will auto reset the router to re gain connectivity MSNswitch is also useful for 1 Saving home users the trouble of constantly having to power cycle their router to re gain internet connectivity 2 Resetting unresponsive device for instance IP camera or NAS servers which otherwise will be inaccessible from remote 3 IT Professionals who need to automatically or remotely reset devices Preventing your connection from timing out or going dormant 5 Having devices on an automatic power schedule Ex Turn on at 9am amp turn off at 5pm Generalized description of network connection Cute reteta iT vetveork dride 3 Outlet pezet if naulter or 3 Femately eror ori Can hed outlet using no jorge reso s iemel conection iow onion outlet from browser infant mewengiag F Cam Hardware Specifications 1 Built in Web Server with 32 Bit RISC CPU 2 10 100Mbps Fast Ethernet Network Access 3
32. rom this list you will still be MSNswitch friend but will not be able to command it 13 UIS user manual Chapter 3 Software amp Web Setup 3 4 2 How to Control MSNswitch using Instant Messaging After setting up and getting connected as above Bring up the MSNswitch MSN dialog box Type anything other than Keywords will invoke MSNswitch to respond with Please type HELP to list available commands Available commands are sensitive SET ON OFF RESET 0 1 72 where O both outlets non case GET IP STATUS SET ON OFF RESET command will return a Done once MSNswitch has completed the action GET IP command will return the WAN IP and the unit s LAN IP address If port forwarding is set but not the domain name user can still use WAN IP to access MSNswitch Web User Interface from internet GET STATUS command will return the following information For Outlet Status the Outlet and Outlet2 name can be assigned This is done at http MSNswitch Configuration Configuration Outlet Setup UIS user manual Files Video Call Games ISbot Available Steven says PF 03 33 hello UISbot says F 03 33 Please type HELF to list available commands Steven says F 03 37 help WISbot says FF 03 37 Outlet Messenger Commands i usage SET ON OFF RESET 0 1 2 where 0 both outlets GET F STATUS dat FF 03 37 on 2009 11 11 Lost MestaQe
33. t the protocol as TCP 8 In the Private IP address box type in the IP Address of MSNswitch network For example type in 192 168 0 5 9 In the Private port boxes these values are automatically filled in from Step 6 and should already show 80 80 11 Click Apply to save the changes you have made MSNswitch should now be configured to work with your router and be accessible from the internet UIS user manual 34 Appendix B IP Address Subnet and Gateway Appendix B IP Address Subnet and Gateway This section discusses Communities Gateways IP Addresses and Subnet masking Communities A community is a string of printable ASCII characters that identifies a user group with the same access privileges For example a common community name is public For security purposes the SNMP agent validates requests before responding The agent can be configured so that only trap managers that are members of a community can send requests and receive responses from a particular community This prevents unauthorized managers from viewing or changing the configuration of a device Gateways Gateway also referred to as a router is any computer with two or more network adapters connecting to different physical networks Gateways allow for transmission of IP packets among networks on an Internet IP Addresses Every device on an Internet must be assigned a unique IP Internet Protocol address An IP address is a 32 bit value compr
34. tch the sender s IP address s first two octets three octets match the sender s IP address s first three octets UIS user manual 36 Appendix C Glossary Appendix C Glossary The Glossary section defines the terms used in this User Manual Ethernet Local Area Network technology originally developed by Xerox Corporation can link up to 1 024 nodes in a bus network Ethernet provides raw data transfer in a rate of 10 megabits sec with actual throughputs in 2 to 3 megabits sec using a baseband single channel communication technique Ethernet uses carrier sense multiple access collision detection CSMA CD that prevents network failures when two devices attempt to access the network at the same time LAN hardware manufacturers use Ethernet protocol their products may not be compatible A computer that attaches to a number of networks and routes packets between them The packets can be different protocols at the higher levels o Internet Protocol The TCP IP standard protocol defines the IP datagram as the unit of information passed across a network IP Address Internet Protocol Address A 32 bit address assigned to hosts participating in a TCP IP network The IP address consists of network and host portions lt is assigned to an interconnection of a host to a physical network Medium Access Control The network layer between the physical and the data link layers Specifically the physical hardware address ex
35. ter the time it occurs in 24hr format 4 2 3 Network This option allows the user to configure the IP address port number and DDNS functions UIS user manual 20 Chapter 4 UIS Web User Interface A Rip 18 0 0 50 Windows Internet Explores Gets ff soto woe x td ip Feoi i hipin eao A G o o bar aiye Toke A MSNs witch tC ae Informetan f EIT a j a Curent Staus System Status Hasire MSH maeh P ddime Subnet Mesh Configuration Default Gateway Soha d ule Qbtan an F address Wareg DHCP i Hatasri H E mpi Porary CHS Servar Pir Segni CNS Serer Pg Oblain DHS Senorm Anomaticaly m Ein Mimar HTF Porn Humber IP Address ress Hostname MSNewitch IP Address 19 1680 150 Subnet Mask Default Gateway Obtain an IP address Using DHCP Hostname By default the hostname LAN Domain Name is set to MSNswitch This allows the unit to be easily located in LAN without needing to know the LAN IP address Just type MSNswitch in a browser while in the same LAN as the device and you will be able to find this Web UI Q Note Ifyou have multiple MSNswitch unit you should assign different System Name to each unit Do this by renaming the Hostname one unit at a time IP Address This determines displays MSNswitch IP address By default the LAN IP address assignment method is set to DHCP IP address assigned by router We suggest changing
36. this to a Fixed IP for ease of management Subnet Mask Display MSNswitch Subnet Mask Gateway UIS user manual 21 Chapter 4 UIS Web User Interface This item set MSNswitch Gateway To learn more about the above see Appendix A IP address Subnet and Gateway Obtain an IP address This allows the user to either manually set or use DHCP default function to obtain the IP address from the router Q Note Click Apply to confirm MSNswitch will reboot If Manually selected user Y IV must now enter the new IP address in the browser in order to open the web UI DNS Server IP Primary ONS Server IP secondary DNS Server P Obtain DNS Servers Automatically v Primary DNS Server IP This item sets MSNswitch primary DNS Server IP address By default this is set to 168 95 1 1 User can set their own preferred DNS server one that is assigned by ISP Secondary DNS Server IP Use this to set MSNswitch Secondary DNS Server IP address MSNswitch will use the Secondary DNS Server IP address if the Primary DNS Server IP address is not working The default IP is 168 95 192 1 Port Number Port Number HTTP Port Numbers a0 HTTP Port Number This determines the LAN port from which the webpage using HTTP protocol is accessible thru your Router By default the LAN port number is 80 lf this port is changed say to 82 then http x x x x 82 where x x x x is MSNswitch LAN IP address as shown in Netility
37. tion all indicator a i Activate JUIS Fuglin Button pie Rocker Fo Oni LAA ori i tocker Power Oni i Of Switch with 104 yverload SNMP card Rtesetiable Circuil LEO Power ani indicabars owned Fig 7 UlS315 description Two fired amp One 90 rotating outlets wah Surge Protector Ried Intemet Lanm ction Imaicator Pont Artivate UIS ener Functor Bulon Green Power Un indikator SNMP cand LED imdicatorg 104 Poe Getta bil ee Circu LAN pori Breaker Fig 8 UlS311 description UIS user manual 5 Chapter 1 Introduction Outlet Fused ON OFF Power Button Input UIS LAN Port ON OFF Button Ti Internet oo Online Offline Indicator Fig 9 UIS322x description UIS user manual Chapter 2 Hardware Setup Chapter 2 Hardware Setup The following details the hardware installation procedure for UIS 315 Step 1 Connect the plug to the main power outlet Step 2 Connect the power plug to the MSNswitch power output port Note In order for MSNswitch to maintain continuous internet connection or reset your xDSL modem Router the router power input must be connected here Step 3 Switch on the power The Power LED light will turn on Step 4 Connect LAN cable from the router to the MSNswitch LAN port The Internet LED light will blink to show that the internet connection is ready Step 5 Press the UIS on off button to activ
38. ust hit enter to login Password Assign a password to the account The administrator can set up to 32 case sensitive passwords Confirm Password Retype the password 4 2 6 MSN Setup in this page allows MSNswitch to be controlled via Instant Messaging tools like MSN UIS user manual 26 Chapter 4 UIS Web User Interface r Mipi az 16i 0 130 Wiera aane Eana g E F E Da Ld 0 a eia geht eos MSNswitch _ information Cure Biahis System taiua Configuratii fi F Dipl Mame Swim 5m hy Comfhgurstion Shea a Porsonal Message bor Accoum Schedule Nobwark l Emal Add Contact Acocants jio access poniral the above woaani Apagun Md oi Suesbem Tore Language Emami Log Fig 11 MSN Settings page MSN Account cin For current MSN account status check the tab Status This determines the status of the MSNswitch MSN account Select either Offline or Online Login ID Enter the Login ID that you have created from Windows Live website for this MSNswitch Password Enter the corresponding password Display Name This is the MSNswitch name as shown on MSN Show a Personal Message for Account Enter a message here This message will be visible to anyone that is in the MSNswitch s MSN friends list UIS user manual 27 Chapter 4 UIS Web User Interface Add Contact Accounts to access control the above account The administrator can assi