Contents

1. the NC contacts are normally closed they open on activating the relay during its active state Authorization control Unauth event opening the door without entering a password from the code lock e g with the key will generate an Unauthorized door opening event it can also be signaled on the output type 93 UNAUTHORIZED ACCESS Alarm on unauth access Unauth alarm when the partition to which the module is assigned is armed unauthorized opening of the door will trigger the alarm and can be additionally signaled on the output type 94 ALARM UNAUTHORIZED ACCESS Max door open time this option defines the time after expiry of which the module will report the Long opened door event to the control panel and activate the audible alarm The duration can be set from 0 to 255 seconds Dependent on door 1 or Dependent on door 2 this function provides a list to choose the door which must be closed for the lock to operate Monitoring of the door state is effected through the IN input in the code lock partition keypad or CA 64 SR expander for proximity card readers or through the zone type 57 TECHNICAL DOOR MONITORING Two dependent doors can be selected The function allows to create a sluice type passage Master users Users this function defines master users users authorized to use the given code lock Alarms FIRE alarm holding down the key will trigger the fire alarm AUX alarm Medical ala
2. or None and the options are deactivated Lack of key operation acknowledgement gives the impression that the code lock does not respond to entering the password Note During the identification process the control panel saves in the module memory a special 16 bit number used for checking the module presence in the system Replacement of the module with another one even having the same address set on the switches without a new identification will result in triggering the alarm module tamper verification error 3 Using the LCD keypad or DLOADX DLOAD64 program configure the code lock functions and define the users authorized to use the given code lock 4 Quit the service mode or the communication session with PC and save the data in the FLASH memory 4 SATEL INT SZ GR INT SZ BL 4 Programming the Code Lock Settings The code lock can be programmed by means of the LCD keypad gt Service mode gt Structure gt Hardware Expanders gt Settings gt expander selection or a computer with DLOADX DLOAD64 program Described below are settings and options available for programming Abbreviations from the LCD keypad display are shown at some of the functions in square brackets BER System Hardware Integra mainboard Module INT SZ address i xv J Es eel LOD keypads si Expansion modules Bus 1 Mame Laboratory Seen Ces Expansion modules Bus T E e acela office F AUK alarm de P Bookkeeping arene j i i JW PA
3. the operating mode of the lock control relay The control function is effected by controlling the state of NO contacts of the relay electromagnetic switch installed on the board inside the code lock housing The relay operation is monostable Basic state of the relay terminals is set by a separate option Opening the door by means of the user function CODE or CODE changes the terminal status to the opposite one for a predetermined period of time Fixed ON time after the door opening function is called by the user CODE the relay gets activated for the Relay ON time and then returns to its normal state INT SZ GR INT SZ BL SATEL 5 Fixed ON time OFF if door open ON open gt off the relay is active until the door is opened the IN input disconnected from common ground but not longer than for the relay ON time Fixed ON time OFF if door closed ON close gt off the relay is active during the time when the door is open the IN input cut off from the common ground and deactivates on closing the door reconnection of the IN input to common ground but not longer than for the relay ON time Relay ON time the time period during which the relay is active Duration of the relay ON time can be from 1 to 255 seconds Relay this option defines the operating mode of the relay contacts NO the NO contacts are normally open they close on activating the relay during its active state NC
4. CODE LOCKS Sanel Wi n Ce INT SZ BL The INT SZ GR and INT SZ BL code locks are the devices designed to work in conjunction with INTEGRA and CA 64 alarm control panels They differ in the backlight color of their keys which is green in the INT SZ GR and blue in the INT SZ BL They provide an easy way to control access to spaces where doors with electrically operated lock are installed and to control closing status of those doors Additionally the code locks can exercise access control in respect of other equipment This manual applies to the code lock with firmware version 1 07 or later 1 Description of code lock The code lock has 12 keys with permanent or temporary automatically activated mode backlight and LED indicators LED designation lt active green color steady light indicates that the lock is cooperating T with the control panel o integra e ACCESS blue color steady light e indicates that the code lock is unblocked what means that the door D 8 can be opened Satel DOOR yellow color steady light indicates that the door is open 1 Bone Baer x 0 Figure 1 Code lock Alternative blinking of all the LEDs from top to bottom indicates lack of communication between the code lock and the control panel This situation may take place when the STARTER program is running in the control panel or when the cable connecting the code lock and the control panel i
5. NIC alarm Je silent Laboratory E Lock feature Alarm 3 incorect codes Warehouse Fixed ON time DEL annie Commercial dept Control Bli output Synoptic Board Fred ON time OFF if door open Control MONG output Partition blocking secretary office on See Fixed ON time OFF if door closed Guard round control h Changing access code Relay ON time E SEC Exit delay clearing enable Ela signal 7 ntl canceled Rela L i T Authorization control mes Sign entm delay NOt NC P Alam on unauth acc FE Sign exit delay F Autos om delay countdown Max door open time fo S 360 IT Acc Code sign hardware Dependent on door 1 CHIME not present JI No auto reset after 3 tamp Dependent op door 2 Confirmin not present E no Ze Sound C Backlight Ce P Code do not disarm we 9 Auto 7 Permane Acces if amed Zone violation Enty delay part Open door if fire f no Ce Part fire alarm Object fire alarm Fire alarm Comments Figure 4 DLOADX program window with options for the code lock Name makes it possible to give an individual 16 character name to the module In the LCD keypad this option can be accessed in the following way Service mode gt Structure gt Hardware gt Expanders gt Name gt expander selection Partition assignment of the code lock to a partition selected from the list Lock feature DLOADX Lock DLOAD64 defines
6. artition will unblock the door controlled by the module Object fire alarm fire alarm in the object will unblock the door controlled by the module fire alarm fire alarm in the system will unblock the door controlled by the module INT SZ GR INT SZ BL SATEL 7 5 Technical Data Nominal elei VOllage 21576 EE 12V DC ES deif lun GUPFENT COMSUMDUOM DEE 66mA Average Current CONSUIMPUON ix2stiswiwssenasiwesncenivevaresdvaverscivere sind vena viedexasiaandsenaeeeseasouaesuaviuand 24mA Maximum voltage switched over by relay 24V Maximum current Switched over by relay 2A Sale MMIC ILA CLAS E II Operating temperature range sissurenssinncercpinorericirotinir ninenin OEE ERENT N nai 10 C 55 C Dimensions length x height x wd 80x127x24mm The latest EC declarations of conformity and certificates are available for downloading on the website www satel pl SATEL sp z 0 0 ul Schuberta 79 80 172 Gdansk POLAND tel 48 58 320 94 00 info satel pl www satel pl
7. es connected to the control panel expander bus In order to determine the code lock address add up the numbers set on particular DIP switches according to Table 1 P MNS INT SZ GR INT SZ BL SATEL 3 address 6 address 22 Figure 3 Addressing examples Five switches make it possible to assign addresses to 32 expanders numbers from O to 31 Addresses of the expanders connected to one bus may not repeat while the addressing sequence is optional It is recommended to assign consecutive addresses Starting from zero to expanders and other modules connected to one bus This will permit problems to be avoided during extension of the alarm system 6 Connect the module power supply to the 12V terminal The code lock supply voltage need not be provided from the control panel mainboard A buffer power supply unit or another expander with power supply may be used for this purpose For details concerning the cable connections see the installer manual for alarm control panels 7 Connect the leads of the door status control detector to the terminals IN and COM 8 Connect the leads for operation control of the electromagnetic door lock or another device to the NO terminals 9 Close the casing 3 Starting the code lock 1 Switch on power supply of the alarm system 2 Call the Expander identification function in the LCD keypad Service mode Structure gt Hardware After identification the value of all settings is either zero
8. nual for the alarm control panel Backlight the audible signaling will be replaced by the blinking keypad illumination as described in the user manual for the alarm control panel Backlight defines the mode of code keypad illumination No keypad backlighting disabled Auto keypad backlighting goes on automatically on pressing any key the function has additional options Submenu Auto backlight in LCD keypad no auto backlight illumination only activated by pressing one of the keys zone violation backlighting activated by pressing a key or by violation of the selected zone entry delay partition backlighting activated by pressing a key or by starting the countdown of entry delay time in the indicated partition Note Automatic code lock keypad illumination is ON for approx 40 seconds from the moment of its activation or from the last press of any key Permanent code lock keypad backlighting is permanently ON No auto reset after 3 tampers each expander automatically disables the tamper alarming in the given expander after three consecutive not cleared tamper alarms This prevents multiple recording of the same events in the control panel memory The option allows this feature to be disabled Open door if fire Doors on fire control mode for the door blocking during fire alarm no fire alarm has no effect on the door blocking Partition fire alarm fire alarm in the p
9. rm holding down the D key will trigger the auxiliary alarm PANIC alarm holding down the Ukey will trigger the PANIC alarm Silent PANIC alarm with this option selected triggering the panic alarm from the code lock keypad will not set off the loud signaling instead a message will be sent to the monitoring station and the output type 12 SILENT ALARM will be activated Alarm 3 incorrect codes 3 wrong codes entering a code unknown to the control panel three times will trigger alarm Options Partition blocking entering the guard code when the partition is armed will temporarily bypass the partition Guard round control entering the guard code CODE or CODE will be recorded as completion of the round Changing access code this option enables the function of the user code changing 6 SATEL INT SZ GR INT SZ BL Signaling Access code signaling hardware enabling of this option will activate the code entry acknowledgement signaling which is independent of the control panel The option is useful in expanded alarm systems in which there is a considerable time lag between entering the code and generating the audible signal by the control panel Confirming this option defines the way of communication between the control panel and the code lock user No the function of code keypad operation acknowledgement is disabled Sound the code keypad will generate beeps as described in the user ma
10. s damaged 2 SATEL INT SZ GR INT SZ BL Information on the use of the code lock can be found in the user manual of control panel Saas Explanations to Fig 2 Iololololololo 1 terminals relay terminals The NO NO 12V DTA CLK COM IN NO terminals are used for control of the door electromagnetic lock door status control input NC If not used it should be short circuited to the common ground common ground 12V power supply input DTA CLK expander bus 2 package of DIP switches for setting individual address of the code lock 3 tamper contact The spring should be pressed against the wall 4 buzzer Figure 2 Schematic view of the code lock electronics board 2 Installation and Connection of the Module Caution Before you start to hook up the module to the existing alarm system make sure that the whole system is disconnected from power supply source Push in the snap catch in the lower part of module plastic casing and remove the cover Pass the lead through the rectangular opening in the lower part of the casing Attach the lower part of the casing to the wall The terminals DTA CLK and COM connect with wires to the expander bus on the control panel PCB 5 Using the DIP switches set the code lock address The address should be set by means of the switches 1 to 5 the status of the other switches is irrelevant This address must differ from those of the other modul

Download Pdf Manuals

image

Related Search

Related Contents

Avaya Business Communications Manager 450 1.0 Configuration Configuration manual  Hotpoint G740 User's Manual  MODE D`EMplOi - TC Electronic  ThermoLine™ Thawers Operator & Service Manual  LUBRI-CuP`* EM & EM-x  Hampton Bay 34002 Installation Guide  Samsung Samsung WB100 Užívateľská príručka  LG V194H User's Manual  CCTP véhicules  SC200R-M16-160 - Applied Robotics  