Home

GS1 series of AC drives

image

Contents

1. 957 00 SJ300 150HFU 20 hp 1 165 00 SJ300 185HFU 25 hp a 1 383 00 SJ300 220HFU 30 hp z 7 1 570 00 Notes Replacement drives do not necessarily have the same physical dimensions mounting hole patterns or wiring terminal arrangements All J300 drives are specified for use with 3 phase power but can be installed in single phase applications Replacement drive requires 3 phase power Ensure that the existing SJ application uses 3 phase input power or that 3 phase power is available Replacement drive is higher horsepower than existing drive Output power of new drive can be parameter limited to the smaller horse power Book 2 14 1 eDR 94 AC Drives 1 800 633 0405 Prices as of April 16 2014 Check Web site for most current prices LUTE Hitachi Drives Cross References To find a suitable replacement for an L100 NES or SJ100 Hitachi drive use the chart to the Hs IVE Volts Hz Sensorless Full Flux s eries Vector Vector right to determine control mode s required and the tables below to determine pos L100 sible replacement part numbers Suggested SJ100 replacements do not necessarily have all GS1 control modes of the original so appropri GS ate drives will be application dependent DURAPULSE Please call Tech Support if there are any 1300 replacement questions Hitachi L100 Cro
2. Relay output 1 common Internal power supply 10 mA 10 VDC Common 0 to 10 VDC 0 to 20 mA or 4 to 20 mA input represents zero to maximum output frequency Note Use twisted shielded twisted pair or shielded lead wires for the control signal wiring It is recommended all signal wiring be run in a separate steel conduit The shield wire should only be connected at the drive Do not connect shield wire on both ends Book 2 14 1 14 eDR 18 AC Drives 1 800 633 0405 Prices as of April 16 2014 Check Web site for most current prices Automation GS1 Specifications Basic Wiring Diagram NES Note Users MUST connect wiring according to the circuit diagram shown below Refer to user manual GS1 M for additional specific wiring information Note Refer to the following pages for explanations and information regarding line reactors and RF filters DR 50 DR 80 Power Source 3 phase 100 120V 10 ONN a 50 60Hz 5 i 200 240V 10 N ONN gt GS1 xxxx 50 60Hz 5 AC Motor 01010 L3 py Use terminals L1 and L2 for 120V or select any two of the power terminals for 240V single phase models Grounding resistance L less than 0 10 Multi function output contacts 120VAC 24VDC 5A 230VAC 2 5A O xX Forward Stop Fault Indication O O amp Reverse Stop RJ 12 OPAC RJ 12 Serial Comm Port re oor N Interface See Warning 0 R
3. eDR 93 Prices as of April 16 2014 Check Web site for most current prices Hitachi Drives Cross References To find a suitable replacement for an SJ300 Drive Sensorless Full Flux Hitachi drive use the chart to the right to Series Volts Hz Vector Vector determine control mode s required and the i L100 tables below to determine possible replace ment part numbers Suggested replace aay ments do not necessarily have all control GS1 modes of the original so appropriate drives GS2 will be application dependent Please call DURAPULSE GS3 Tech Support if there are any replacement SJ300 questions Hitachi J300 Cross Reference Hitachi J300 AC Drives Possible Replacements Part No Horsepower GS1 Price Price DURAPutse GS3 Price SJ300 004LFU 0 5 hp GS1 20P5 117 00 158 00 242 00 SJ300 007LFU 1 0 hp GS1 21P0 134 00 177 00 242 00 SJ300 015LFU 2 0 hp GS1 22P0 164 00 251 00 293 00 SJ300 022LFU 3 0 hp a Z 309 00 347 00 SJ300 037LFU 5 0 hp z 363 00 400 00 SJ300 055LFU 75hp 465 00 549 00 SJ300 075LFU 10 hp 698 00 SJ300 110LFU 15 hp 889 00 SJ300 150LFU 20 hp z 1 104 00 SJ300 185LFU 25 hp 1 298 00 SJ300 220LFU 30 hp 1 486 00 S J300 007HFU 1 0 hp 261 00 323 00 SJ300 015HFU 2 0 hp 303 00 360 00 SJ300 022HFU 3 0 hp 357 00 385 00 SJ300 040HFU 5 0 hp 410 00 427 00 S J300 055HFU 7 5 hp 586 00 613 00 SJ300 075HFU 10 hp 725 00 734 00 SJ300 110HFU 15 hp
4. 0 hp 164 00 251 00 293 00 9J100 022NFU 3 0 hp 309 00 347 00 9J100 037LFU 5 0 hp 363 00 400 00 9J100 055LFU 7 5 hp 465 00 549 00 SJ100 075LFU 10 hp 698 00 SJ100 004HFU 0 5 hp 261 00 323 00 SJ100 007HFU 1 0 hp 261 00 323 00 SJ100 015HFU 2 0 hp 303 00 360 00 SJ100 022HFU 3 0 hp 357 00 385 00 SJ100 040HFU 9 0 hp 410 00 427 00 SJ100 055HFU 7 5 hp 586 00 613 00 SJ100 075HFU 10 hp 725 00 734 00 Notes Replacement drives do not necessarily have the same physical dimensions mounting hole patterns or wiring terminal arrangements Replacement drive requires 3 phase input power Ensure that the existing application uses 3 phase input power or that 3 phase power is available Replacement drive is higher horsepower than existing drive Output power of new drive can be parameter limited to the smaller horsepower Book 2 14 1 www automationdirect com drives AC Drives eDR
5. or lt DOWN gt buttons or potentiometer Frequency Setting External Signal Potentiometer 5kQ 0 5W 0 to 10 VDC input impedance 47kQ 0 to 20 mA 4 to 20 mA input impedance 250Q Multi function inputs 1 to 3 3 steps JOG UP DOWN command RS485 communication setting Operation Keypad Setting by lt RUN gt lt STOP gt buttons Setting External Signal DI1 DI2 DI3 DI4 can be combined to offer various modes of operation RS485 communication port Multi Function Input Signal Multi step selection 0 to 3 Jog Accel decel inhibit First second accel decel switch Counter PLC operation External base block N C N O selection Outputs Multi Function Output Signal AC drive operating Frequency attained Non zero speed Base Block Fault indication Local remote indication PLC operation indication Operating Functions Automatic voltage regulation S curve Over voltage stall prevention DC braking Fault records Adjustable car ried frequency Starting frequency setting of DC braking Over current stall prevention Momentary power loss restart Reverse inhibition Frequency limits Parameter lock reset Protective Functions Overcurrent overvoltage undervoltage electronic thermal motor overload Overheating Overload Self testing Operator Devices 5 key 4 digit 7 segment LED 3 status LEDs potentiometer Programming Parameter values for setup and review fault codes
6. 485RJ12 CBL 2 Software GSoft KEP Direct OPC Server KEP Direct GS1 1xxx drives require 115V class input line reactors and 230V class output line reactors Single phase fuse kits and fuses are used only with GS1 1xxx drives Fuse Kit Replacement Fuses GS EDRV100 ZL CDM RJ12X4 ZL CDM RJ12X10 Book 2 14 1 www automationdirect com drives AC Drives e Prices as of April 16 2014 Check Web site for most current prices GS1 General Specifications General Specifications Control System Sinusoidal Pulse Width Modulation carrier frequency 3kHz 10kHz Rated Output Frequency 1 0 to 400 0 Hz limited to 9999 motor rpm Output Frequency Resolution 0 1 Hz Overload Capacity 150 of rated current for 1 minute Torque Characteristics Includes manual torque boost auto slip compensation starting torque 130 5 0Hz DC Braking Operation frequency 60 0Hz 0 30 rated voltage Start time 0 0 5 0 seconds Stop time 0 0 25 0 seconds Acceleration Deceleration Time 0 1 to 600 seconds can be set individually Voltage Frequency Pattern V F pattern adjustable Settings available for Constant Torque low and high starting torque Variable Torque low and high starting torque and user configured Stall Prevention Level Keypad 20 to 200 of rated current Setting by lt UP gt
7. 5 9 m s 0 6g 10 to 55 Hz Altitude 1 000 m or less Location indoors no corrosive gases or dust 1 Protective structure is based upon EN60529 2 The ambient temperature must be in the range of 10 to 40 C If the range will be up to 50 C you will need to set the carrier frequency to 2 1 kHz or less and derate the output current to 80 or less See our Web site for derating curves 3 The storage temperature refers to the short term temperature during transport 4 Conforms to the test method specified in JIS CO911 1984 Watt Loss Chart Ground braid copper lugs GS1 Drive Model GS1 10P2 9999 FOR PAINTED SUB PANELS GS1 10P5 SCRAPE THE PAINT FROM UNDER asr20P2 V pai eared GS1 20P5 Star washers point ground GS1 21P0 GS1 22P0 Warning AC drives generate a large amount of heat which may damage the AC drive Auxiliary cooling methods Air Flow are typically required in order to not exceed maximum ambient i 4 temperatures M th ll i Book 2 14 1 www automationdirect com drives AC Drives eDR 17 Prices as of April 16 2014 Check Web site for most current prices GS1 Specifications Terminals Main Circuit Wiring Description Li L2 L3 Input power AC drive output Ground AUTOMATION DIRECT Ti T2 T3 Control Circuit Terminals Terminal Symbol Description Relay output 1 normally open
8. 6 1 0 1 6 27 ingle 400 oj Three phase Rated Input Voltage Single phase 1907120 A0 10 Singlethree phase 200 240 VAC 10 50 60 Hz 5 200 240 VAC 10 50 60 Hz 5 DIES Motor Rating Three phase corresponds to double the i Rated Output Voltage input voltage Three phase corresponds to the input voltage Rated Input Current A 6 9 4 9 1 9 6 5 2 7 9 7 5 1 Rated Output Current A 1 6 25 1 6 25 4 2 Watt Loss 100 I W 18 4 26 8 44 6 Weight kg Ib 2 20 2 20 2 20 Dimensions HxWxD mm in 132 0 x 68 0 x128 1 5 20 x 2 68 x 5 04 Accessories Line Reactor LR 1xxPx xxx refer to GS DURApulse Drives Accessories Line Reactors section for exact part RF Filter RF220X00A Single Phase GS 10P2 FKIT 1P GS 10P5 FKIT 1P GS 20P2 FKIT 1P GS 20P5 FKIT 1P GS 21P0 FKIT 1P Three Phase a GS 20P2 FKIT 3P GS 20P5 FKIT 3P GS 21P0 FKIT 3P GS 22P0 FKIT 3P Single Phase GS 10P2 FUSE 1P GS 10P5 FUSE 1P GS 20P2 FUSE 1P GS 20P5 FUSE 1P GS 21P0 FUSE 1P Three Phase GS 20P2 FUSE 3P GS 20P5 FUSE 3P GS 21P0 FUSE 3P GS 22P0 FUSE 3P Ethernet Communications module for GS Series Drives DIN rail mounted USB to RS 485 PC Communication Adapter USB 485M RS 485 Communication Distribution Module for creating plug and play RS 485 networks RS 485 Serial Cable GS Drive to DL06 D2 260 GS 485HD15 CBL 2 RS 485 Serial Cable GS Drive to ZIPLink CDM Module GS
9. IC CLICK and Productivity3000 I O Modules to 3rd Party Devices When wanting to connect I O to another device within close proximity of the I O modules no extra terminal blocks are necessary when using the ZIPLink Pigtail Cables ZIPLink Pigtail Cables are prewired to an I O terminal block with color coded pigtail with soldered tip wires on the other end Using the I O Modules to 3rd Party Devices selector tables located in this section 1 Locate your PLC I O module 2 Select a Z PLink Pigtail Cable that is compatible with your 3rd party device Solution 3 GS Series and DURAPuLse Drives Communication Cables Need to communicate via Modbus RTU to a drive or a network of drives ZIPLink cables are available in a wide range of configurations for connecting to PLCs and SureServo SureStep Stellar Soft Starter and AC drives Add a ZIPLink communications module to quickly and easily set up a multi device network www automationdirect com drives Using the Drives Communication selector tables located in this section 1 Locate your Drive and type of communications 2 Select a Z PLink cable and other associated hardware Book 2 14 1 AC Dries eDR 91 Prices as of April 16 2014 Check Web site for most current prices ZIP NK Wiring Solutions WAUTOMATIONDIRECT Solution 4 Serial Communications Cables ZIPLink offers communications cables for use with DirectLOGIC CLICK Using the Serial Communications Cables s
10. Operator Interface Parameter Monitor Master Frequency Output Frequency Scaled Output Frequency Output Voltage DC Bus Voltage Output Direction Trip Event Monitor Trip History Monitor Key Functions RUN STOP DISPLAY RESET PROGRAM ENTER lt UP gt lt DOWN gt Enclosure Rating Protected chassis IP20 Ambient Operating Temperature 10 to 40 C 14 F to 104 F w o derating Storage Temperature 20 to 60 C 4 F to 140 F during short term transportation period Environment Ambient Humidity 0 to 90 RH non condensing Vibration 9 8 m s2 1G less than 10Hz 5 88 m s2 0 6G 20 to 50 Hz Installation Location Altitude 1000m or lower above sea level keep from corrosive gas liquid and dust Book 2 14 1 eDR 16 AC Drives Programming Software GSOFT 1 800 633 0405 Prices as of April 16 2014 Check Web site for most current prices LOO GS1 Specifications Installation M Understanding the installation requirements for your GS1 drive will help to ensure that it will operate within its environmental and electrical limits NOTE Never use only this catalog for installation instructions or operation of equipment refer to the user manual GS1 M NES Environmental Specifications Protective Structure 1 P20 Ambient Operating R Temperature 2 10 to 40 C Storage i 5 Temperature 3 es Humidity to 90 no condensation Vibration 4
11. Prices as of April 16 2014 Check Web site for most current prices GS1 Series Introduction Overview The GS1 series of AC drives is our most atfordable and compact inverter offering V Hz control with general purpose appli cation features These drives can be contigured using the built in digital keypad which also allows you to set the drive speed start and stop and monitor specific parameters or with the standard RS 485 serial communications port Standard GS1 features include one analog input four programmable digital inputs and one programmable normally open relay output Book 2 14 1 eDR 14 AC Drives GS1 Series Drives Motor Rating 115V Single Phase Input 230V Three Phase Output 230V Single Phase Input 230V Three Phase Output 230VThree Phase Input Output Features e Simple Volts Hertz control e Pulse Width Modulation PWM e 3 10 kHz carrier frequency IGBT technology e 130 starting torque at 5Hz e 150 rated current for one minute e Electronic overload protection e Stall prevention e Adjustable accel and decel ramps e S curve settings for acceleration and decel eration e Manual torque boost e Automatic slip compensation DC braking e Built in EMI filter e Three skip frequencies e Trip history e Integral keypad and speed potentiometer e Programmable jog speed e Three programmable preset speeds e Four programmable digital inputs e One programmable analog input
12. S 485 or O A T Jog Pog 4 SG Communication Port 5 5V Common Signal Optional ZIPLink serial communica tion cables available for plug and play connectivity to AutomationDirect PLCs See the comm cable selection Analog voltage 10V 10mA matrix on page DR 93 ARES nine max ZIP ink Potentiometer Al wave STS 3 5kQ Analog current 0 20mA 4 20mA CM Factory default setting xX Factory default source of frequency command is via the keypad potentiometer Main circuit power terminals Control circuit terminal J Shielded leads WARNING Do not plug a modem or telephone into the GS1 RJ 12 Serial Comm Port or permanent damage may result Terminals 2 and 5 should not be used as a power source for your communication connection Book 2 14 1 www automationdirect com drives AC Drives eDR Prices as of April 16 2014 Check Web site for most current prices GS1 Specifications Dimensions 68 0 2 68 56 0 2 20 59 se AUTOMATION n ea DIRECT g L D ES PROG ES ENTER _ RS JF 120 0 4 72 132 0 5 20 128 1 5 04 _ 123 4 4 86 128 1 5 04 Unit mm in eDR 20 AC Drives 1 800 633 0405 Prices as of April 16 2014 Check Web site for most current prices ZIP wx Wiring Solutions WAUTOMATIONDIRECT Wiring Solutions using the ZIPLink Wiring System ZIPLinks eliminate th
13. e One programmable relay output e RS 485 Modbus communications up to 19 2K e Optional Ethernet communications e Two year warranty e UL cUL CE listed Hp kW Accessories AC line reactors RF filter e Fuse kits and replacement fuses Ethernet interface e Four and eight port RS 485 multi drop termination board e Serial communication cables available for creating plug and play RS 232 RS 485 net works with AutomationDirect PLCs See the comm cable matrix on page DR 93 e KEPDirect I O or OPC Server e GSoft drive configuration software e USB 485M USB to RS 485 PC adapter see Communications Products chapter for detailed information Detailed descriptions and specifications for GS accessories are available in the GS DURAPULSE Accessories section Typical Applications e Conveyors e Fans e Pumps e Shop tools GS1 series part numbering system GS1 2 OPS Applicable Motor Capacity OP2 1 4hp OP5 1 2hp 1P0 1hp 2P0 2hp Input Voltage 1 100 120VAC 2 200 240VAC Series Name 1 800 633 0405 Prices as of April 16 2014 Check Web site for most current prices Automatiow GS1 Series Specifications 115V 230V CLASS GS1 Series Model GS1 10P2 GS1 10P5 GS1 20P2 GS1 20P5 GS1 21P0 GS1 22P0 Price 99 00 117 00 113 00 117 00 134 00 164 00 HP 1 4 hp 1 2 hp 1 4 hp 1 2 hp thp 2hp kW 0 2 kW 0 4 kW 0 2 kW 0 4 kW 0 7 kW 1 5 kW Rated Output Capacity 200V kVA 0 6 1 0 0
14. e normally tedious process of wiring between devices by utilizing prewired cables and DIN rail mount connector modules It s as simple as plugging ina cable connector at either end or terminating wires at only one end Prewired cables keep installation clean and efficient using half the space at a fraction of the cost of standard terminal blocks There are several wiring solutions available when using the ZIPLink System ranging trom PLC O to ZIPLink Connector Modules that are ready for field termination options for connecting to third party devices GS DuraPulse and SureServo Drives and specialty relay transorb and communications modules Pre printed O specitic adhesive label strips for quick marking of ZIPLink modules are provided with ZIPLink cables See the following solutions to help determine the best ZIPLink system for your application Solution 1 DirectLOGIC CLICK and Productivity3000 I O Modules to Z PLink Connector Modules When looking for quick and easy O to field termination a ZIPLink connector module used in conjunction with a prewired ZIPLink cable consisting of an I O terminal block at one end and a multi pin connector at the other end is the best solution VAUTOMATIONDIRECT Using the PLC I O Modules to ZIPLink Connector Modules selector tables located in this section 1 Locate your I O module PLC 2 Select a Z PLink Module 3 Select a corresponding Z PLink Cable Solution 2 DirectLOG
15. elector and Productivity3000 CPUs that can also be used with other communica table located in this section tions devices Connections include a 6 pin RJ12 or 9 pin 15 pin and 1 Locate your connector type 25 pin D sub connectors which can be used in conjunction with the RJ12 a Salacha cable or D Sub Feedthrough modules Solution 5 Specialty Z PLink Modules For additional application solutions ZIPLink modules are available in Using the ZIPLink Specialty Modules selector table a variety of configurations including stand alone relays 24VDC and located in this section 120VAC transorb modules D sub and RJ12 feedthrough modules 1 Locate the type of application communication port adapter and distribution modules and SureServo 5 Selecta ZIPLink module 50 pin O interface connection STO Ss ZAR OND RE A 654 yyy a e 21 a 32 har 1 6 me Solution 6 Z PLink Connector Modules to 3rd Party Devices Using the Universal Connector Modules and Pigtail If you need a way to connect your device to terminal blocks without all Cables table located in this section that wiring time then our pigtail cables with color coded soldered tip 1 Select module type wires are a good solution Used in conjunction with any compatible 2 Select the number of pins ZIPLink Connector Modules a pigtail cable keeps wiring clean and 3 Galactcable easy and reduces troubleshooting time Book 2 14 1 eDR 92 AC Drives 1 800 633 0405 Pric
16. es as of April 16 2014 Check Web site for most current prices ZinK Motor Controller Communication WAUTOMATIONDIRECT Drive Motor Controller GS DURAPutse SureServo SureStep Stellar Z PLink Selector Drive Motor Controller Communications ZIPLink Cable Cable Cable Other Hardware Controller Comm Port Type Network Protocol Connects to Comm Port Type 2 meter length Connectors Required DLO6 PLCs 5 Port 2 HD15 GS 485HD15 CBL 2 RU12 to HD15 D2 260 CPU a ears GSI RJ12 RS 485 Modbus RTU GS EDRV100 RJ12 GS EDRV CBL 2 eee 0 ZL CDM RJ12Xxx RJ12 GS 485RJ12 CBL 2 FA ISOCON 5 pin Connector GS ISOCON CBL 2 RJ12 to 5 pin plug CLICK PLCs p Port 2 RJ12 DLO5 PLCs DLO6 PLCs RS 232 Modbus RTU D2 250 1 CPU Port 2 HD15 GS RJ12 CBL 2 RJ12 to RJ12 FA 15HD D2 260 CPU D4 450 CPU Port 3 25 pin FA CABKIT GS2 RJ12 P3 550 CPU Port 2 RJ12 z DLO6 PLCs Port 2 HD15 GS 485HD15 CBL 2 RU12 to HD15 D2 260 CPU Ta RS 485 Modbus RTU GS EDRV100 RJ12 GS EDRV CBL 2 C RJ12 to RJ12 ZL CDM RJ12Xxx RJ12 GS 485RJ12 CBL 2 FA ISOCON 5 pin Connector GS ISOCON CBL 2 RJ12 to 5 pin plug DLO6 PLCs Port 2 HD15 GS 485HD15 CBL 2 RU12 to HD15 D2 260 CPU 2 oura uce aN a2 RS 485 Modbus RTU GS EDRV100 RJ12 GS EDRV CBL 2
17. ss Reference Hitachi L100 AC Drives Possible Replacements Part No Horsepower Price Price DURAPULSE Price L100 002NFU 0 25 hp 113 00 158 00 Go3 2iP0 242 00 L100 004NFU 0 5 hp 117 00 158 00 GS3 21P0 242 00 L100 007NFU 1 0 hp 134 00 177 00 242 00 L100 015NFU 2 0 hp 164 00 251 00 293 00 L100 022NFU 3 0 hp 7 309 00 347 00 L100 037LFU 9 0 hp 363 00 400 00 L100 055LFU 7 5 hp 465 00 549 00 L100 075LFU 10 hp 698 00 L100 004HFU 0 5 hp 261 00 323 00 L100 007HFU 1 0 hp 261 00 323 00 L100 015HFU 2 0 hp 303 00 360 00 L100 022HFU 3 0 hp 357 00 385 00 L100 040HFU 5 0 hp 410 00 427 00 L100 055HFU 7 5 hp 586 00 613 00 L100 075HFU 10 hp 725 00 734 00 Notes Replacement drives do not necessarily have the same physical dimensions mounting hole patterns or wiring terminal arrangements Replacement drive requires 3 phase input power Ensure that the existing application uses 3 phase input power or that 3 phase power is available Replacement drive is higher horsepower than existing drive Output power of new drive can be parameter limited to the smaller horsepower Hitachi J100 AC Drives Part No Horsepower Price Price DuRAPULSE Price SJ100 002NFU 0 25 hp 113 00 158 00 Go RO 242 00 SJ100 004NFU 0 5 hp 117 00 158 00 Gos 2ir0 242 00 SJ100 007NFU 1 0 hp 134 00 177 00 GS3 21P0 242 00 SJ100 015NFU 2
18. z GS3 ne RJ12 to RJ12 ZL CDM RJ12Xxx RJ12 GS 485RJ12 CBL 2 FA ISOCON 5 pin Connector GS ISOCON CBL 2 RJ12 to 5 pin plug DLO6 PLCs stellar D2 250 1 CPU Port 2 HD15 SRA4485HD15 CBL 2 RU45 to HD15 Soft Starter RU45 RS 485 Modbus RTU ee SR44 RS485 SR44 Series D2 260 CPU ZL CDM RJ12Xxx RJ12 SR44 485RJ45 CBL 2 RU45 to RU12 CLICK PLCs 3 Port 2 RJ12 DLO5 PLCs DLO6 PLCs RS 232 Modbus RTU D2 250 1 CPU Port 2 HD15 SVC 232RJ12 CBL 2 6 pin IEEE to RJ12 FA 15HD D2 260 CPU SureServo IEEE1394 CN3 D4 450 CPU Port 3 25 pin FA CABKIT P3 550 CPU Port 2 RJ12 DLO6 PLCs Port 2 HD15 SVC 485HD15 CBL 2 6 pin IEEE to HD15 D2 260 CPU 2 RS 485 Modbus RTU 3 ZL CDM RJ12Xxx RJ12 SVC 485RJ12 CBL 2 6 pin IEEE to RJ12 USB 485M RJ45 SVC 485CFG CBL 2 6 pin IEEE to RJ45 DLO6 PLCs D2 250 1 CPU Port 2 HD15 STP 232HD15 CBL 2 HD15 pintoRJ12 SureStep RJ12 RS 232 ASCII D2 260 CPU Port2 z DLO5 PLCs RJ12 STP 232RJ12 CBL 2 RJ12 to RJ12 CLICK PLCs nn When using the ZL CDM RJ12Xxx ZIPLink Communication Distribution Module replace the lowercase xx with the number of RJ12 ports i e 4 for four ports or 10 for ten ports ex ZL CDM RJ12X4 or ZL CDM RJ12X10 The SR44 RS485 Communications Adapter must be installed for RS 485 communications with the Stellar soft starters www automationdirect com drives AC Drives Book 2 14 1

Download Pdf Manuals

image

Related Search

Related Contents

神戸第2地方合同庁舎庁舎維持管理業務(合庁分担)仕様書  miniDSP 10x10 Hd User Manual  user manual manuel d`utilisation manual del usuario manual    Computer Hardware - Cengage Learning  User Manual - Newegg.com  DOLPHIN SUPREME M5 EN FR IT SP DEU User Instructions Guide  Computer Gear 26-1012 SATA cable  Manuale montaggio,uso e manutenzione    