Home

Speedy Vet Pill Counter User Manual

image

Contents

1. After adding the inventory item the main window will automatically enter into Cycle Count Mode see Figure 7 with the item that was just added as the active item This provides a Speedy Vet Pill Counter User Manual 7 double check to the user that the item was added correctly The count display should always equal 50 after adding an inventory item this does not apply to injectables Add Inventory Item Figure 6 Add Inventory Item window Speedy Vet Pill Counter User Manual FH Speedy Vet Pill Counter S Ioj x File Inventory Setup Help CYCLE COUNT MODE Active Thyrsosyn 0 5mg Vedco 350989275860 One moisture pack AnD FX1200i tablets Figure 7 Enters Cycle Count Mode after Adding Item Equals 50 capsules Adding an Injection The injection feature of Speedy Vet Pill Counter is meant to be used in Cycle Count Mode only and is an approximation An assumption is made that the weight of all injections are equal The accuracy depends on the type of injectable Water based injectables will be fairly accurate thicker injectables will have larger errors e g Euthasol The following steps will be highlighted in the Add Inventory Item window as the process is stepped through see Figure 8 Step 1 Same as before Scan the barcode of the item to be added Important the scale should be empty and read 0 00g at this point Step 2 Same as before Enter the description of the item to b
2. HID Keyboard Emulation UL IBM Hand Held USB Start Speedy Vet Pill Counter by double clicking the icon on the desktop Enter your Customer ID and Product Key that you received by email may be up to 24 hours after registering Select COM port if asked to do so the default highest number COM port works on most installations Installation is complete For detailed operation please refer to the owner manual below or by selecting Help and then View Help on the menu bar Or you can visit www SpeedyVetPillCounter com to watch detailed how to videos If you need further assistance please contact technical support by email or phone at www SpeedyVetPillCounter com Speedy Vet Pill Counter User Manual Overview The Speedy Vet Pill Counter for Veterinarians software and scale is designed to automate the process of counting pills during dispensing of medication to patients and during inventory cycle counts A medication is first calibrated by weighing the empty bottle with cap and then weighing the empty bottle with 50 pills This allows the software to record the empty bottle weight and the average pill weight for each medication along with its barcode description and notes With this information the software can calculate the number of pills in a bottle simply by placing the entire bottle with contents on the scale inventory cycle count mode It can also calculate the
3. amount of injectable used Toggle between Cycle Count Mode and Dispensing Mode Switching between Cycle Count Mode and Dispensing mode is done by clicking the Toggle Counting Mode shortcut icon on the menu bar or on the menu select Inventory and then Toggle Counting Mode Cycle Count Mode IMPORTANT Before switching to Cycle Count Mode make sure the scale reads 0 00g The scale must be zeroed before performing a cycle count To perform a cycle count scan the barcode of a bottle and place it on the scale After a short delay for the scale to settle the count will be shown in the blue window The last count shown in the window is automatically copied to the Windows clipboard in order to paste it into a Word document or Excel document The user can choose between two modes of automatic clipboard copying 1 Item Details plus count or 2 Count only The method used can be chosen on the menu select Setup and then Select Clipboard Method Dispensing Mode To use Speedy Vet Pill Counter to dispense medications toggle the count mode by clicking the Toggle Counting Mode shortcut icon gt on the menu bar Dispensing should be displayed above the blue count window Scan the barcode of the medication to be dispensed Place a pill vial on the scale You will see a count displayed in the blue count window as the weight of the vial is added to the scale In order to start at a zero weight select t
4. number of pills being dispensed into a pill vial dispensing mode In addition to pills Speedy Vet Pill Counter can be used to count the volume of liquid in an injection bottle thus adding to the ability for veterinarians to do a complete inventory cycle count of all medications quickly and easily Initial Setup On initial use the COM port will have to be set to communicate with the scale An error message see Figure 1 may be displayed to let the user know that communication with the scale is not setup properly Click OK to move on to the main Speedy Vet Pill Counter window see Figure 2 where the COM port can be set ES l Error reading port COMI Check available ports and the cable O x File Inventory Setup Help 4 Dispensing Mode Units AnD FX1200i Figure 2 Start Up Window Speedy Vet Pill Counter User Manual 5 On the menu click Setup and then Select COM Port see Figure 3 to select the correct COM port In this window see Figure 4 simply select the correct COM port and click OK Note it will usually be the last COM port available Once the correct COM port is selected pills can be counted FH Speedy Vet Pill Counter i 10 x File Inventory Search Inventory Select COM Port Select Clipboard Method Dispensing Made Available Scales AnD FX1200i Units Figure 3 Select COM Port Menu Item Choose COM Port ojx Availab
5. Speedy Vet Pill Counter User Manual Copyright 2013 Installing Speedy Vet Pill Counter Hardware This installation guide explains how to connect the Speedy Vet Pill Counter hardware to your computer and the steps of installing the software NOTE do not plug in the USB side of any cable to the computer until directed to do so Unpack the scale and its power supply the USB Serial cable installation does not use the 25 pin adapter USB Serial cable CD located behind the cable packaging the 9 pin mini gender changer and the barcode reader Place the scale on a flat surface and adjust the front legs to center the level located on the front of the scale Connect the power supply to the plug in the back of the scale Turn the scale on by pushing the On Off button Connect the 9 pin mini gender changer to the USB Serial cable Screw in the thumbscrews Connect the USB Serial cable with mini gender changer to the 9 pin port on the back of the scale Screw in the thumbscrews to tighten Speedy Vet Pill Counter User Manual Installing Speedy Vet Pill Counter Software In your web browser go to www SpeedyVetPillCounter com registration htm Complete the registration You will receive your registration key by email On the registration page select the Download link at the top right of the page pink download icon Select Run You may be alerted that downloading software can be harmful
6. Vet Pill Counter folder and click Speedy Vet Pill Counter Update This should be done periodically to check for software and internal database updates Speedy Vet Pill Counter User Manual 12 Laminate funnel for best results Useful Paper Funnel a a tj a 7 i ean a lien ww Pe k e ra a t OM ja N N k F M k 4 H w M i a NN i w I j M _ a i a a No Y To form funnel cut along dotted lines fold and tape A J j 7 j k ff I hy 7 i a l i Sie ee el i i 4 I 4 i 7 li j ri i F F Fi k 2 Fa A Pa Ban a Se _ i Speedy Vet Pill Counter User Manual 13
7. e added Step 3 Check the Injection checkbox Place a known quantity of injectable on the scale for example a full 10ml bottle of the injectable that has not been used If it is not an unused bottle the injectable can be drawn into a syringe and measured before this step Wait for a stable scale reading and hit OK Step 4 Enter the number of ml s that are in the injectable container e g 10 Wait for a stable scale reading and hit OK Step 5 ml is automatically entered into this text box However the user can change it if desired Hit OK Step 6 Enter any notes that may need to be displayed for this particular inventory item and hit OK Step 7 After adding the inventory item the main window will automatically enter into Cycle Count Mode see Figure 9 with the item that was just added as the active item This provides a double check to the user that the item was added correctly The count display should always equal the amount of injectable in the full container after adding an inventory item Speedy Vet Pill Counter User Manual 9 Add Inventory Item Figure 8 Add Inventory Item Window for an Injectable Speedy Vet Pill Counter User Manual 10 FH Speedy Vet Pill Counter 0 x File Inventory Setup Help Metoclopramide 5ma ml Injection CYCLE COUNT MODE Active Metoclopramide 5mg ml Injection 191510 AnD FA12001 Figure 9 Enters Cycle Count Mode after Adding Item Equals
8. he Re Zero button on the scale This will cause the scale to read 0 00g and the count in the count window will be 0 The medication can now be placed in the pill vial and Speedy Vet Pill Counter will display how many pills are in the vial Deleting an Inventory Item To delete an inventory item click the x button on the menu bar or select Delete from the Inventory menu item shown in Figure 10 Speedy Vet Pill Counter User Manual 11 H Speedy Vet Pill Counter Inventory Setup Add Item CYCLE COUNT MODE Toggle Counting Mode 390989203335 INTERNAL tablets AnD FX1200i Figure 10 Delete an Inventory Item A pop up window will ask to make sure deleting the item is desired see Figure 11 Internal database items cannot be deleted and the user will be told that the procedure cannot be completed Delete item Figure 11 Delete an Inventory Item Pop up Printing the Inventory List To print the current Inventory List click File on the menu bar and select Print see Figure 12 The list is automatically printed to the default Windows printer fa x W Speedy Vet Pill Counter CYCLE COUNT MODE Active Thyrosyn Tablets 5mg I 350989203535 INTERNAL AnD FX1200i tablets Figure 12 Print Inventory List Software Updates To check for software updates click on the Windows Start icon select the Programs folder select the Speedy
9. if you are running Windows 7 or Windows 8 Click Run Anyway or More Info then Run Anyway Follow all defaults during installation except rebooting computer if asked to reboot do this after installation is finished Several driver installations will start in addition to the main Speedy Vet install app POS NET Motorola Symbol OPOS USB to Serial Follow all defaults for these driver installations as well except rebooting On some versions of Windows a driver may appear in the background and installation appears to halt in this case click on the blue icon in the task tray to bring it to the front Once you have your registration key connect both USB cables barcode reader and USB Serial cable to the computer After connecting both USB cables the drivers for these two devices will be installed This device driver installation may take a minute Do not start the Speedy Vet Pill Counter app yet The barcode scanner is shipped in keyboard emulation mode For the most intuitive user experience it is suggested to place the barcode scanner in USB mode To do this scan the IBM Hand Held USB barcode below Speedy Vet Pill Counter User Manual Step 7 Tutorials or HELP ill If you would like to use the barcode scanner within your practice management software it can be left in the keyboard emulation mode or scan barcode below Note that this limits the user experience in Speedy Vet Pill Counter
10. le COM Ports Figure 4 Choose from Available COM Ports Internal Inventory Database Speedy Vet Pill Counter is pre installed with common veterinary drugs Internal inventory database items are noted with an I at the end of the name INTERNAL is also noted in the notes section below the name and barcode Unless otherwise noted in the notes section these inventory items are all measured with 1 a moisture pack if shipped with one 2 paper instructions removed 3 cotton and foil removed from the bottle Adding an Inventory Item To add an inventory item click the Add Item shortcut icon on the menu bar or on the menu select Inventory and then Add Item see Figure 5 Speedy Vet Pill Counter User Manual 6 FH Speedy Vet Pill Counter ioj x File Inventory Setup Help Add tem at P Delete tem Dispensing Mode Toggle Counting Mode AnD FX12001 Units Figure 5 Add Item Menu Item This will bring up the Add Inventory Item window see Figure 6 where a step by step process will be followed Empty Scale e f xj MPORTANT Before proceeding make sure the scale is empty and reads 0 00g It is important to keep any weight off the scale until prompted to do so the scale should read 0 00g initially Itis also important to take the bottle off of the scale when filling it again the scale should read 0 00g before weighing the bottle with pil
11. ls The warning above gives a warning to this effect each time an item is added Note also that the scale is very sensitive and may be affected by drafts To maximize accuracy it is best to place it in a draft free area The following steps will be highlighted in the Add Inventory Item window as the process is stepped through Adding an injectable inventory item will be discussed separately below Step 1 Scan the barcode of the item to be added Note that some pharmaceuticals do not have a barcode In this case simply hit OK to move to the next step If the barcode has been used before the user will be asked if the item is to be replaced Step 2 Enter the description of the item to be added Step 3 Place the empty container on the scale For most veterinary practices the empty container should include the bottle lid and moisture absorbing packet It should not include cotton foil or paper instructions Wait for a stable scale reading and click OK Step 4 Place 50 pills in the container Important take the empty container off the scale to fill it with 50 pills The scale should read 0 00g before placing the container with pills on the scale Failure to do so may result in count errors Wait for a stable scale reading and click OK Step 5 Enter the units of the inventory item e g pills capsules etc and click OK Step 6 Enter any notes that may need to be displayed for this particular inventory item and click OK Step7

Download Pdf Manuals

image

Related Search

Related Contents

DIVING SUITS COLLECTION  precautionary statements declaraciones preventivas  Pocket PC V35 User Manual - Support  USER MANUAL  user guide - Newport City Council  96-97 LT-1/LT-4 OBDII Wiring Harness Street & Performance  HSM SECURIO B24 4.5x30  Samsung UA55JU7000L manual de utilizador  Audiovox AS2ARSS Owner's Manual  