Operation Manual C1520M-B (1/04)

image

Contents

1. CM9760 DMR Data Manager Installation Operation Manual LISTED C1520M B 1 04 Pelco 3500 Pelco Way Clovis CA 93612 5699 USA www pelco com In North America and Canada Tel 800 289 9100 or FAX 800 289 9150 International Customers Tel 1 559 292 1981 or FAX 1 559 348 1120 CONTENTS Section Page IMPORTANT SAFETY 5 2 3 CRP ON ee T 4 ua8 4 FREAR VIEW eee ease 4 LED ACTIVITY INDICATORS 4 DP SWITCHE 4 2 25 pex 4 SCREW 02222 4 9 ONIN CR ee 4 4 INSTALLATION 5 CONNECTIONS AND SWITCH 5 22 22 2222 12 den DATA MERGER MODE P 5 SWITCH TABLES 7 DATA MERGER MODE D PROTOCOL 8 PORT EXPANDER MODE nennen nans 10
2. Figure 12 Comms Keyboard Expander Screen Pelco Manual C1520M B 1 04 NOTE he Keyboard Expander tields appear once you define the ports Refer to Figure 12 Pelco Manual C1520M B 1 04 Set the port number equipment number baud rate and parity The baud rate and parity must be the same as the baud and parity of Switch 1 on the CM9760 DMR a Port 8 CM9760 DMR is connected to this port on the CC1 unit b Equipment Number 23 The DMR is always this number when operating as a port expander for keyboards c Baud 19200 Parity Even Select the keyboard expander port number Although the keyboards are connected to Ports 2 5 you must reference them as Ports 1 4 Assign a keyboard number KBD Num to each keyboard expander port Figure 12 shows that the first keyboard expander port is assigned number 5 Click Save 19 20 10 11 12 Click the Operators tab Assign a PIN to the operator number The operator number is the same as the keyboard number KBD Num Figure 13 shows that the PIN for operator number 5 is 5555 You can edit the operator name and PIN in the Edit PIN fields Click Save Figure 13 Operators Screen Pelco Manual C1520M B 1 04 OPERATION The CM9760 DMR will function based on the mode you have selected After making all connections and settings refer to the operation manual of each peripheral component for detailed instructio
3. AC ADAPTER DATA CABLE WIRED VIA lt SCREW TERMINAL ADAPTERS 2522225225222551 5880091999289824 6800 THE DX7100 6800 AND CM6700 7 25554 MA BAUD RATES MUST BE 2400 THE PTZ CAMERA BAUD RATES DX7100 MUST BE 2400 9 Hn SS e 7100 ALARMS 10 18 1 1 6 2 7 12 COM 1 PORT PIN CONVERTER THE PTZ MUST BE SET TO ACCEPT D PROTOCOL CONTROL FOR INFORMATION ON SETTING THE RECEIVER ADDRESS RS 422 ADAPTER FOR D TYPE CONTROL REFER TO THE DOCUMENTATION A SUPPLIED WITH THE PTZ EQUIPMENT T gt R ON DMR YOU CAN LOOP VIDEO CABLES FROM CM6800 CM6700 TO DX7100 DX7000 OR USE A DISTRIBUTION AMP SUCH AS THE CM9760 MDA REFER TO THE SWITCHER AND CAMERA INSTALLATION MANUALS FOR VIDEO CONNECTION INSTRUCTIONS the DX7100 DX7000 CM6700 a maximum of 16 PTZ cameras be controlled through a single DMR For control of more than 16 PTZ cameras a second DMR is required Figure 5 Data Merger Mode D Protocol Pelco Manual C1520M B 1 04 10 PORT EXPANDER MODE CAMERAS In this mode a PTZ output from the CC1 can have up to 64 cameras on it The CM9760 DMR takes this high speed multi control cable and breaks it down int
4. DATA DATA O DATA O DATA O DATA O Ed HERE 21155 AC ADAPTER RJ45 REVERSED RJ 45 REVERSED CABLE TO ANY AVAILABLE PORT ON cM9760 cc4 LIHECC T m CM9505UPS Elle OT Lee e RJ 45 STRAIGHT CABLES THE CC1 BAUD RATE MUST 19200 oS og PET Z SESS 55 292222 4 7 LES SS S LES Gay 255 1220222 E gt SAS 20154 THE KEYBOARD BAUD RATES MUST BE 4800 Figure 7 Port Expander Mode Keyboards 12 Pelco Manual C1520M B 1 04 PROGRAMMING You must define the ports and cameras in the CM9760 MGR System Manager before you can use the CM9760 DMR Refer to the CM9760 MGR Installation User Manual C547M A for instructions on installing this software The following steps and screenshots are only examples of possible configurations for each mode except for the Data Merger Mode D Protocol Additional configurations are possible DATA MERGER 1 Open the system manager and log in Figure 8 System Window Pelco Manual C1520M B 1 04 13 14 Click the Sys Setup icon The Configuration Files window opens Enter a configuration name and node number and then click Add Node Highlight the node and click Setup Files The Setup System Configuration DMR window opens 4 Sy Figure 9 Configuration Files Window Pelco Manual C1520M B 1 04 5 Comms tab 6 Set the port number equipment number
5. baud rate and parity for each unit up to four you connect to DMR Ports 2 5 Figure 10 shows the system manager setup files for only one CC1 a Port 6 The CM9760 DMR is connected to this port on one of the units b Equipment Number 9 The CM9760 DMR is always this number when operating as a data merger for CC1 units c Baud 9600 d Parity None The baud rate and parity for additional CC1s can be different and must be reflected in the system manager setup files 7 Click Save Setup Syehem aig quratenn OUTE E nomm ul mmm Gern Figure 10 Comms Screen Pelco Manual C1520M B 1 04 15 NOTE You can enter the 8 Click the Cameras tab Cameras must be defined on each 1 unit port number of any They are all communicating 9 Inthe PTZ Port data fields enter the CC1 port number the CM9760 DMR is connected lo the PTZ cameras wa an to and the port address for the PTZ camera HS 422 communication Interface 10 Click Save ee Setup System Lonhgqursthon OME 2256662566256 hh EE OR GR Figure 11 Cameras Screen 16 Pelco Manual C1520M B 1 04 PORT EXPANDER FOR CAMERAS 1 Open the system manager and log in 2 Click the Sys Setup icon The Configuration Files window opens See Figure 9 3 Enter
6. CM6800s and CM6700s to these connectors DB9 CONNECTOR Reserved for future use POWER JACK You can plug either a 120V AC adapter or 230V AC adapter into this jack These adapters drop the power jack s input voltage to 9 0 VAC Pelco Manual C1520M B 1 04 INSTALLATION The following items are supplied e CM9760 DMR AC adapter 1 10 ft 3 m reversed cable 5 screw terminal adapters 4 screws and nylon washers for attaching to the rack mount MOUNTING NOTE 7 e unit is shipped Install the CM9760 DMR unit in a 19 inch 48 26 cm rack The unit occupies one rack unit from the factory with the 1 75 inches or 4 45 cm of space You can mount the unit to something other than a rack ears attached standard 19 inch rack by relocating the rack ears to another location Figure 3 Rack Mount Installation NOTE Countries CONNECTIONS AND SWITCH SETTINGS requiring CE compli ance must use DATA MERGER MODE P PROTOCOL shielded reversed In the P protocol the CM9760 DMR merges PTZ commands from CM9760 CC1 units cables Pelco recom allowing you to control up to 32 PTZ cameras on one port You can set the data manager to menas multi operate with two three or four CC1 units To operate the unit in protocol set switch 7 on conductor shielded SW6 OFF 24 gauge twisted pairs such as Belden Refer to Figure 4 for connections 9687 1 Connect up to 32 PTZ cameras to Port 1 Refer to Table A for terminal connections
7. from the apparatus Only use attachments accessories specified by the manufacturer Use only with the cart stand tripod bracket or table specified by the manufacturer or sold with the apparatus When a cart is used use caution when moving the cart apparatus combination to avoid injury from tip over Unplug this apparatus during lightning storms or when unused for long periods of time Refer all servicing to qualified service personnel Servicing is required when the apparatus has been damaged in any way such as power supply cord or plug is damaged liquid has been spilled or objects have fallen into the apparatus the apparatus has been exposed to rain or moisture does not operate normally or has been dropped Apparatus shall not be exposed to dripping or splashing and no objects filled with liquids such as vases shall be placed on the apparatus WARNING To reduce the risk of fire or electric shock do not expose this apparatus to rain or moisture CAUTION These servicing instructions are for use by qualified service personnel only To reduce the risk of electric shock do not perform any servicing other than that contained in the operating instructions unless you are qualified to do so DESCRIPTION DIP SWITCHES LED ACTIVITY INDICATORS DB9 CONNECTOR lt gt 9 0 T ACTIVE DATA The CM9760 DMR Data Manager is a five port data distribution unit that can be progr
8. 18 T8 Operators OCI NETT Tm 20 14 Fide4S Cable E 21 15 CM9760 DMR Dimension sci nu decia 22 LIST OF TABLES Table Page A Screw Terminal 7 B opo ao ORE 7 C BS NN RNC 7 PTZ Port Addresses 17 1520 1 04 IMPORTANT SAFETY INSTRUCTIONS Pelco Manual C1520M B 1 04 1 10 11 12 13 14 15 16 17 Read these instructions Keep these instructions Heed all warnings Follow all instructions Do not use this apparatus near water Clean only with dry cloth Do not block any ventilation openings Install in accordance with the manufacturer s instructions Do not install near any heat sources such as radiators heat registers stoves or other apparatus including amplifiers that produce heat Do not defeat the safety purpose of the polarized or grounding type plug A polarized plug has two blades with one wider than the other A grounding plug has two blades and a third grounding prong The wide blade or the third prong are provided for your safety If the provided plug does not fit into your outlet consult an electrician for replacement of the obsolete outlet Protect the power cord from being walked on or pinched particularly at plugs convenience receptacles and the point where they exit
9. 2 Connect CM9760 CC1 units to Ports 2 5 of the data manager You must use 45 reversed cables to make all connections 3 Setthe switches Refer to Tables B and C Figure 4 shows optimum switch settings a SW6 set switch 1 ON if you have two CC1s connected to Ports 2 amp b SWO set switch 2 ON if you have three or four CC1s connected to Ports 2 5 c SWG set switch 8 ON if you want to give priority control to the CC1 on the lower numbered port d SWG set the remaining switches OFF 4 Connect the supplied AC adapter from the DMR unit and into a wall outlet Pelco Manual C1520M B 1 04 5 DIP SWITCH 1 MERGES PORTS 2 amp 3 TO PORT 1 DIP SWITCH 2 ON OPTIMUM SETTINGS OPTIMUM SETTINGS MERGES PORTS 2 5 TO PORT 1 BAUD 9600 BAUD 19200 DIP SWITCH 7 OFF PARITY NONE PARITY NONE P PROTOCOL INTERFACE RS 422 INTERFACE RS 422 DIP SWITCH 8 ON GIVES PRIORITY CONTROL TO THE LOWER NUMBERED PORT FOR EXAMPLE PORT 2 HAS PRIORITY OVER PORT 3 REZRE 1234 5678 NOTE IF DIP SWITCH 8 IS OFF PRIORITY CONTROL IS ONAFIRST COME FIRST SERVE BASIS CM9760 DMR PORT il 2 4 5 e i ACTIVE RERE ACTIVE O J RERE ACTIVE ATI p llall ACTIVE a DATA pata 678 8781 pata ere pata TET E AC ADAPTER RJ 45 REVERSED CABLES DATA CABLE WIRED VIA SCRE
10. Notices Pelco the Pelco logo Spectra Genex Legacy Esprit and Camclosure are registered trademarks of Pelco Copyright 2004 Pelco All rights reserved 24 Pelco Manual C1520M B 1 04
11. PORT EXPANDER MODE KEYBOARDS 12 PROGRAMMING 22222 49 Tm 13 DATA MERGER 13 PORT EXPANDER FOR CAMERAS 17 PORT EXPANDER FOR 5 8 18 Mec 21 TROUBLESHOOTING Dreirad 21 SPECIFICATION 5 22 REGULATORY NOTICES 255 2 0 25835 342 220924 Via e Eu por dax eu E dr 23 WARRANTY AND RETURN INFORMATION 24 LIST OF ILLUSTRATIONS Figure Page 1 msn mi S 4 2 4 3 Rack Mount Installation 5 4 Data Merger Mode P Protocol a conne 6 5 Data Merger Mode D 9 6 Port Expander Mode 11 7 Port Expander Mode Keyboards 12 8 eccles 13 9 Configuration Files VVIEIOOW 14 10 seti 15 11 Cameras SCICON 16 12 Comms Keyboard Expander Screen
12. S SIDE BY SIDE TAB SIDE DOWN USE THE COLOR RUN OF THE WIRES TO DETERMINE CABLE TYPE COMPARED COLOR RUN IS IN OPPOSITE DIRECTION Figure 14 RJ 45 Cable Types 21 22 SPECIFICATIONS ELECTRICAL Input Voltage Power Data Ports Input Output Indicators GENERAL Dimensions Operating Temperature Unit Weight MECHANICAL Connectors Power Data Communication 120V AC external adapter 230V AC external adapter 25 RJ 45 connectors screw terminal connectors DB9 connector One green power LED Five green port LEDs Five yellow data LEDs See Figure 15 32 to 122 F 0 to 50 C 5 20 1 2 36 kg 9 0 VAC jack RJ 45 screw terminals DB9 Design and product specifications subject to change without notice 7 85 19 93 19 00 48 26 SYsTEMEHT 17 40 44 20 00990 NOTE VALUES IN PARENTHESES ARE CENTIMETERS ALL OTHERS ARE IN INCHES Figure 15 CM9760 DMR Dimension Diagram Pelco Manual C1520M B 1 04 REGULATORY NOTICES Pelco Manual C1520M B 1 04 This device complies with part 15 of the FCC Rules Operation is subject to the following two conditions 1 this device may not cause harmful interference and 2 this device must accept any interference received including interference that may cause undesired operation RADIO AND TELEVISION INTERFERENCE This equipment has been tested and found to comply wit
13. ST BE 19200 ACTIVE DATA ACTIVE DATA ie CM9760 DMR RRETT ERR GROUND DAISY CHAINING 2ND PTZ PORTS 2 5 EACH SUPPORT UP 16 CAMERAS REFER TO THE SWITCHER AND CAMERA INSTALLATION MANUALS FOR VIDEO CONNECTION INSTRUCTIONS 20153 Figure 6 Port Expander Mode Cameras Pelco Manual C1520M B 1 04 11 PORT EXPANDER MODE KEYBOARDS NOTE 77 DMR unit is In this mode four CM9760 keyboards can communicate with one CC1 This saves port Shipped from the factory in usage on the rear of the CM9760 CC1 because only one port is being used instead of four this mode Refer to Figure 7 for connections 1 Connect a CM9760 CC1 unit to Port 1 You must use an RJ 45 reversed cable 2 Connect CM9760 keyboards to Ports 2 5 of the data manager You must use 45 reversed cables to make all connections 3 Set the DIP switches Refer to Tables and C Figure 7 shows default switch settings 4 Connect the supplied AC adapter from the DMR unit and into a wall outlet DEFAULT SETTINGS DEFAULT SETTINGS DIP SWITCH 4 ON BAUD 19200 BAUD 4800 PORT EXPANDER PARITY EVEN PARITY EVEN FOR KEYBOARDS INTERFACE RS 422 INTERFACE RS 422 2345678 2345678 A Lafoea 12345678 CM9760 DMR 5 ul cweo mme meer ceo creo eme rr
14. Table A for terminal connections Connect D protocol units DX7100 DX7000 CM6800 CM6700 to Ports 2 5 of the data manager You must use 45 reversed cables to make all connections Set the DIP switches Refer to Tables B and C Figure 5 shows optimum switch settings a SW6 set switch 1 ON if you have two D protocol units connected to Ports 2 and 3 b SW6 set switch 2 ON if you have three or four D protocol units connected to Ports 2 5 c SWG set switch 8 ON if you want to give priority control to the D protocol unit on the lower numbered port d SWO set switches 3 6 OFF Connect the supplied AC adapter from the DMR unit and into a wall outlet Pelco Manual C1520M B 1 04 DIP SWITCH 1 MERGES PORTS 2 amp 3 TO PORT 1 DIP SWITCH 2 ON OPTIMUM SETTINGS OPTIMUM SETTINGS MERGES PORTS 2 5 TO PORT 1 BAUD 2400 BAUD 2400 DIP SWITCH 7 ON PARITY NONE PARIT Y NONE D PROTOCOL INTERFACE RS 422 INTERFACE RS 422 DIP SWITCH 8 ON GIVES CONTROL PRIORITY TO THE LOWER NUMBERED PORT FOR EXAMPLE PORT 2 HAS PRIORITY OVER PORT 3 NOTE IF DIP SWITCH 8 IS OFF PRIORITY CONTROL IS ONA FIRST COME FIRST SERVED BASIS 41 2 3 4 5 2 Acco FARRAR ineo mem Q 1 e
15. W TERMINAL ADAPTERS RRITT 68586 9760 1 9760 1 e e Gano oto 3 e gp aR THE 1 32 E 6 98 emm BAUD RATES 9 sss MUST BE 9 B 19200 SPECTRA 9996 5 9760 1 1 THE PTZ CAMERA BAUD RATES MUST 9600 9760 1 3 K e B B 1 iE ED EN 6 3 b bbb 5 5 amp E E 5 e 1 ao BERR Pip elie 6262 e 1 YOU MUST CONNECT AN 45 REVERSED CABLE TO A PORT ON EACH 1 AS ILLUSTRATED YOU CAN USE THE SAME PORT NUMBER ON EACH CC1 ACTIVE O ACTIVE DATA Q DAISY CHAINING 32ND PTZ 2ND PTZ 20151 THE SCREW CONNECTOR ON PORT 1 SUPPORTS UP TO 32 CAMERAS REFER TO THE SWITCHER AND CAMERA INSTALLATION MANUALS FOR VIDEO CONNECTION INSTRUCTIONS Figure 4 Data Merger Mode P Protocol 6 Pelco Manual C1520M B 1 04 Table Screw Terminal Connections Terminal RS 232Function 5 422 Function 5 485 Function SWITCH TABLES Table B SW1 SW5 Settings BAUD 1 2 3 4 5 INTERFACE 6 7 8 of 480 of on of of on RS232 of on notused Use either of the two DIP switch settings for no parity Use eith
16. a configuration name and node number and then click Add Node 4 Highlight the node and click Setup Files The Setup System Configuration DMR window opens 5 Click the Comms tab See Figure 10 6 Set the port number equipment number baud rate and parity The baud rate and parity must be the same as the baud and parity of Switch 1 on the CM9760 DMR a Port 7 The CM9760 DMR is connected to this port on the CC1 unit b Equipment Number 19 The CM9760 DMR is always this number when operating as a port expander for cameras c Baud 19200 d Parity Even NOTE You can only use 7 Click Save 76 camera addresses for each port For example the 8 Click the Cameras tab See Figure 11 address for cameras 17 33 and 49 is also 1 See 9 Inthe PTZ Port data fields enter the CC1 port number the CM9760 DMR is connected Table D to and the port address for the PTZ camera 10 Click Save Table D PTZ Port Addresses DMR Port 5 Camera Number 49 5 51 52 5 5 55 5 5 5 59 Pelco Manual 1520 1 04 17 PORT EXPANDER FOR KEYBOARDS 1 Open the system manager and log in 2 Click the Sys Setup icon The Configuration Files window opens See Figure 9 3 Enter a configuration name and node number and then click Add Node 4 Highlight the node and click Setup Files The Setup System Configuration DMR window opens 5 Click the Comms tab Leki if Rh LET ern 0 DE 18
17. ammed to operate in three modes 1 Data Merger for CM9760 CC1 units P protocol and DX7100 DX7000 CM6800 CM6700 units D protocol 2 Port Expander for pan tilt zoom PTZ cameras 3 Port Expander for CM9760 keyboards FRONT VIEW Figure 1 shows the front of the unit The green power LED indicates the unit is on Figure 1 Front View REAR VIEW Figure 2 shows the back of the unit FF 5 MODE 1 BEHEWEEH j DEHEEHEEH BEEHEHHE crvEO BEBEEREH 12345678 DATA 12345678 DATA 12345678 12345678 12345678 12345678 RRLTT 2 9 9 SCREW TERMINAL CONNECTORS MODE SELECTION RJ 45 CONNECTORS DIP SWITCH DATA 01133 Figure 2 Rear View LED ACTIVITY INDICATORS Each of the five ports has a green LED and a yellow LED The green LEDs indicate the port is selected The yellow LEDs blink when there is port activity DIP SWITCHES The back of the unit has six DIP switches You can program the hardware of the five data merger ports with the first five DIP switches You can select the unit mode with the sixth switch RJ 45 CONNECTORS You can use these five connectors to connect CM9760 CC1 units or CM9760 keyboards SCREW TERMINAL CONNECTORS You can connect PTZ cameras DX7100s DX7000s
18. er of the two DIP switch settings for RS 422 interface Table C SW6 Settings SW6 SETTINGS FUNCTION Data Merger Ports 2 amp 3 to Port 1 off P protocol on D protocol Ports 2 5 to Port 1 on D protocol Pon Expander Cameras of of on of of of of Use these DIP switch settings if you have three or four units connected to Ports 2 5 Set DIP switch 8 ON for priority control when in the Data Merger Mode on Data Merger off off P protocol off ff Pelco Manual C1520M B 1 04 7 NOTE Aefer to the DX7100 DX7000 CM6800 or CM6700 Installatior Operation manual as appro prate for programming Instructions DATA MERGER MODE D PROTOCOL You can also set the data manager to operate in D protocol allowing you to connect D protocol units DX7100 DX7000 CM6800 and CM6700 units and control PTZ cameras connected to Port 1 of the data manager For a CM6800 unit a maximum of 32 PTZ cameras can be controlled through a single DMR A DX7100 DX7000 CM6700 unit can address cameras 1 16 only therefore a maximum of 16 PTZ cameras can be controlled through a single DMR For control of more than 16 PTZ cameras a second DMR is required contact Pelco Technical Support at 1 800 289 9100 or 1 559 292 1981 for additional information To operate the data manager in D protocol set switch 7 on SW6 ON Refer to Figure 5 for connections 1 2 Connect up to 32 PTZ cameras to Port 1 Refer to
19. h the limits of a Class B digital device pursuant to part 15 of the FCC rules These limits are designed to provide reasonable protection against harmful interference in a residential installation This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful interference to radio communications However there is no guarantee that the interference will not occur in particular installation If this equipment does cause harmful interference to radio or television reception which can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one or more of the following measures Heorient or relocate the receiving antenna Increase the separation between the equipment and the receiver Connect the equipment into an outlet circuit different from that to which the receiver is connected Consult the dealer or an experienced radio TV technician for help You may also find helpful the following booklet prepared by the FCC How to Identify and Resolve Radio TV Interference Problems This booklet is available from the U S Govern ment Printing Office Washington D C 20402 Changes and Modifications not expressly approved by the manufacturer or registrant of this equipment can void your authority to operate this equipment under Federal Communica tions Commission s rules I
20. ispute regarding the warranty of a product which does not fall under the warranty conditions stated above please include a written explanation with the product when returned Method of return shipment shall be the same or equal to the method by which the item was received by Pelco RETURNS In order to expedite parts returned to the factory for repair or credit please call the factory at 800 289 9100 or 559 292 1981 to obtain an authorization number CA number if returned for credit and RA number if returned for repair All merchandise returned for credit may be subject to a 20 restocking and refur bishing charge Goods returned for repair or credit should be clearly identified with the assigned CA or RA number and freight should be prepaid Ship to the appropriate address below f you are located within the continental U S Alaska Hawaii or Puerto Rico Service Department Pelco 3500 Pelco Way Clovis CA 93612 5699 f you are located outside the continental U S Alaska Hawaii or Puerto Rico Intermediate Consignee Ultimate Consignee American Overseas Air Freight Pelco 320 Beach Road 3500 Pelco Way Burlingame CA 94010 Clovis CA 93612 5699 USA USA REVISION HISTORY Manual Date C1520M 9 01 C1520M A 4 02 C1520M B 1 04 Comments Original version Added Data Merger Mode D Protoco section Added Figure 5 Revised Figure 5 and associated text Added references to DX7100 where applicable Updated Regulatory
21. n order to maintain compliance with FCC regulations shielded cables must be used with this equipment Operation with non approved equipment or unshielded cables is likely to result in interference to radio and television reception 23 WARRANTY AND RETURN INFORMATION WARRANTY Pelco will repair or replace without charge any merchandise proved defective in material or workmanship for a period of one year after the date of shipment Ex ceptions to this warranty are as noted below Five years on Pelco manufactured cameras CC3500 CC3600 CC3700 and MC3500 MC3600 Series two years on all other cameras Three years on Genex Series multiplexers server and keyboard and 090 Series Camclosure Camera System Two years on 100 150 200 and 300 Series Camclosure Camera Systems Two years on cameras and all standard motorized or fixed focal length lenses Two years on Legacy CM6700 CM6800 CM6800E CM8500 CM9500 CM9740 CM9760 Matrix DF5 and DF8 Series Fixed Dome products Two years on Spectra Esprit and PS20 Scanners including when used in continuous motion applications Two years on Esprit and WW5700 series window wiper excluding wiper blades Eighteen months on DX Series digital video recorders One year except video heads on video cassette recorders VCRs Video heads will be covered for a period of six months Six months on all pan and tilts scanners or preset lenses used in continuous motion applications that is pre
22. ns on how to operate those devices TROUBLESHOOTING Why is the yellow data LED not blinking when connect a keyboard Make sure all devices are connected properly Make sure you are using a reversed cable See Figure 14 Why is the yellow data LED not blinking Check your system manager setup when send messages to a camera Why doesn t the green active LED come on Why is the yellow LED of the KBD port blinking and the yellow LED of the CC1 port not blinking Why is the keyboard offline even though the yellow LEDs on the KBD port and CC1 port are blinking Why can t control the camera Make sure the AC adapter is connected from the unit and into a wall outlet Check your DIP switch settings Make sure the CC1 is plugged into port 1 it is reserved for this port Check the DIP switches for the proper baud and parity Make sure the baud and parity settings to the CC1 match those in the system manager Check the camera wiring Make sure the DIP switch settings of the PTZ device match those of the DMR Check your system manager setup What should do if can t find a solution to Call Pelco s 24 hour technical support at a problem 1 800 289 9100 or 1 559 292 1981 COMPARED COLOR RUN IS IN SAME DIRECTION BROWN BROWN Pelco Manual C1520M B 1 04 TO IDENTIFY A CABLE TYPE PHYSICALLY ORIENT THE RJ 45 CABLE AS DEPICTED IN THE ILLUSTRATIONS ORIENT THE CONNECTOR
23. o groups of 16 at a slower speed for direct use by the PTZ cameras Refer to Figure 6 for connections 1 Connect CM9760 CC1 unit to Port 1 You must use an 45 reversed cable 2 Connect PTZ cameras to Ports 2 5 of the data manager Up to 16 cameras can be connected to each port Refer to Table A for terminal connections Setthe DIP switches Refer to Tables and C Figure 6 shows optimum switch settings 4 Connect the supplied AC adapter from the DMR unit and into a wall outlet Pelco Manual C1520M B 1 04 OPTIMUM SETTINGS OPTIMUM SETTINGS DIP SWITCH 3 ON BAUD 19200 BAUD 4800 PORT EXPANDER PARITY EVEN PARITY NONE FOR PTZ CAMERAS INTERFACE RS 422 INTERFACE RS 422 ON ON ON tee P m 12345678 12345678 12345678 CM9760 DMR 5 mee core veo bm DATA O DATA DATA DATA O DATA O AC ADAPTER DATA CABLES WIRED 45 REVERSED VIA SCREW TERMINAL CABLE TO ANY ADAPTERS AVAILABLE PORT ON THE CC1 CM9760 CC1 5 s THE PTZ be NW CAMERA BAUD HE 1 16 1 16 1 16 1 16 RATES MUST 088 a B BE 4800 b e S Oi eje e e SPECTRA SPECTRA SPECTRA SPECTRA 9 4 RJ 45 REVERSED CABLE VIDEO SWITCHER THE CC1 BAUD RATES MU
24. set scan tour and auto scan modes Pelco will warrant all replacement parts and repairs for 90 days from the date of Pelco shipment All goods requiring warranty repair shall be sent freight prepaid to Pelco Clovis California Repairs made necessary by reason of misuse alteration normal wear or accident are not covered under this warranty Pelco assumes no risk and shall be subject to no liability for damages or loss resulting from the specific use or application made of the Products Pelco s liability for any claim whether based on breach of contract negligence infringement of any rights of any party or product liability relating to the Products shall not exceed the price paid by the Dealer to Pelco for such Products In no event will Pelco be liable for any special incidental or consequential damages including loss of use loss of profit and claims of third parties however caused whether by the negli gence of Pelco or otherwise The above warranty provides the Dealer with specific legal rights The Dealer may also have additional rights which are subject to variation from state to state If a warranty repair is required the Dealer must contact Pelco at 800 289 9100 or 559 292 1981 to obtain a Repair Authorization number RA and provide the following information 1 Model and serial number 2 Date of shipment P O number Sales Order number or Pelco invoice number 3 Details of the defect or problem If there is a d