Home
G303 Data Sheet/Manual PDF
Contents
1. outdoor applications Users can enter data through the front panel 32 button keypad that has user identifiable keys SAFETY SUMMARY All safety related regulations local codes and instructions that appear in the manual or on equipment must be observed to ensure personal safety and to prevent damage to either the instrument or equipment connected to it If equipment is used in a manner not specified by the manufacturer the protection provided by the equipment may be impaired Do not use the controller to directly command motors valves or other actuators not equipped with safeguards To do so can be potentially harmful to persons or equipment in the event of a fault to the controller WARNING EXPLOSION HAZARD SUBSTITUTION OF COMPONENTS MAY IMPAIR SUITABILITY FOR CLASS DIVISION 2 CLASS II DIVISION 2 CLASS III DIVISION 2 CAUTION Read complete instructions prior to installation and operation of the unit A CompactFlash is a registered trademark of CompactFlash Association sold by AA Electric 1 CONFIGURED USING CRIMSON SOFTWARE VERSION 2 0 OR LATER UP TO 5 RS 232 422 485 COMMUNICATIONS PORTS 2 RS 232 AND 1 RS 422 485 ON BOARD 1 RS 232 AND 1 RS422 485 ON OPTIONAL COMMUNICATIONS CARD 10 BASE T 100 BASE TX ETHERNET PORT TO NETWORK UNITS AND HOST WEB PAGES USB PORT TO DOWNLOAD THE UNIT S CONFIGURATION FROM A PC OR FOR DATA TRANSFERS TO A PC UNIT S CONFIGURATION IS STORED IN NON VOLATILE M
2. AMBER 100 BASE TX Communications The Crimson communications manual contains additional information on Ethernet sold by AA Electric 4 RS232 PORTS The G303 has two RS232 ports There is the PGM port and the COMMS port Although only one of these ports can be used for programming both ports can be used for communications with a PLC The RS232 PGM port can be used for either master or slave protocols with any G303 configuration The RS232 COMMS and RS422 485 COMMS ports are multiplexed because they share the same hardware Both COMMS ports can be used with master protocols However when the RS232 COMMS port is used with a slave protocol the RS422 485 COMMS port is not available Examples of RS232 communications could involve another Red Lion product or a PC By using a cable with RJ12 ends on it and a twist in the cable RS232 communications with another G3 product or the Modular Controller can be established Red Lion part numbers for cables with a twist in them are CBLPROGO CBLRLCO1 or CBLRC02 3 G3 RS232 to a PC Connections G3 RJ12 Name PC DB9 Name 4 COMM 1 DCD 5 Tx R 2 Rx TX M CONNECTING A G303 OPERATOR ICMS INTERFACE TO AN ICM5 CO CBLPROGO ICM5 DIP Switch Settings elie tt ON gt ON KAMYTNMORDAD H nMYTNHOR aaa qauwZz ono WW Sano eos ZZ ZZZZ egggg 72 5Z 56 S555 onton FFF SO YDS Ton
3. AND COMPLIANCES SAFETY UL Recognized Component File E179259 UL61010 1 CSA 22 2 No 61010 1 Recognized to U S and Canadian requirements under the Component Recognition Program of Underwriters Laboratories Inc UL Listed File E211967 UL61010 1 UL1604 CSA 22 2 No 61010 1 CSA 22 2 No 213 M1987 LISTED by Und Lab Inc to U S and Canadian safety standards Type 4X Enclosure rating Face only UL50 IECEE CB Scheme Test Certificate US 9737 UL CB Scheme Test Report E179259 V01 S04 Issued by Underwriters Laboratories Inc IEC 61010 1 EN 61010 1 Safety requirements for electrical equipment for measurement control and laboratory use Part 1 IP66 Enclosure rating Face only IEC 529 ELECTROMAGNETIC COMPATIBILITY Emissions and Immunity to EN 61326 Electrical Equipment for Measurement Control and Laboratory use Immunity to Industrial Locations Electrostatic discharge EN 61000 4 2 Criterion A 4 kV contact discharge 8 kV air discharge Electromagnetic RF fields EN 61000 4 3 Criterion A 10 V m Fast transients burst EN 61000 4 4 Criterion A 2 kV power 1 kV signal Surge EN 61000 4 5 Criterion B 1 kV L L 2 kV L amp N E power RF conducted interference EN 61000 4 6 Criterion A 3 V rms Emissions Emissions EN 55011 Class B Notes 1 Criterion A Normal operation within specified limits 2 Criterion B Temporary loss of performance from which the unit self recovers 9 CONSTRUCTION Steel rear metal enclosure with NEMA
4. FOR SYSTEM SET UP AND DIAGNOSTICS AND IS NOT INTENDED FOR PERMANENT CONNECTION In order to transfer data from the CompactFlash card via the USB port a driver must be installed on your computer This driver is installed with Crimson and is located in the folder C Program Files Red Lion Controls Crimson 2 0 Device after Crimson is installed This may have already been accomplished if your G303 was configured using the USB port Once the driver is installed connect the G303 to your PC with a USB cable and follow Mounting the CompactFlash instructions in the Crimson 2 user manual Note that using the USB port for frequent data transfers is not recommended For frequent data transfers it is recommended that the Ethernet connection be used Through the Ethernet connection a web page can be set up to view logged data Refer to the Crimson 2 0 manual for details ETHERNET COMMUNICATIONS Ethernet communications can be established at either 10 BASE T or 100 BASE TX The G303 unit s RJ45 jack is wired as a NIC Network Interface Card For example when wiring to a hub or switch use a straight through cable but when connecting to another NIC use a crossover cable The Ethernet connector contains two LEDs A yellow LED in the upper right and a bi color green amber LED in the upper left The LEDs represent the following statuses YELLOW solid Link established YELLOW flashing Data being transferred GREEN 10 BASE T Communications
5. TB 1 8 TxA TxA 130k 2 5 TxEN 0C 5 TEN 00 Modular Controller ans H ia 6 GND 5v 23 130k 4 RxB RX 3 RxA 130k 6 GND Note All Red Lion devices connect Ato A and B to B except for Paradigm devices Refer to www redlion net for additional information sold by AA Electric 1 800 237 8274 Lakeland FL Lawrenceville GA Greensboro NC East Rutherford NJ www A AElectric com 5 DH485 COMMUNICATIONS The G303 s RS422 485 COMMS port can also be used for Allen Bradley DH485 communications When this port is configured to communicate DH485 the RS232 COMMS port can not be used because the ports share the same hardware and the G303 multiplexes the ports to communicate via two protocols WARNING DO NOT use a standard DH485 cable to connect this port to Allen Bradley equipment A cable and wiring diagram are available from Red Lion G3 to AB SLC 500 CBLAB003 Connections RJ45 RLC Name RJ45 A B Name 1 TxB 1 2 TxA 2 8 RxA 3 N N lt SOFTWARE UNIT OPERATION FRONT PANEL LEDS There are three front panel LEDs Shown below is the default status of the LEDs LED INDICATION RED TOP LABELED PWR FLASHING Unit is in the boot loader no valid configuration is loaded STEADY YELLOW MIDDLE OFF No CompactFlash card is present STEADY Valid CompactFlash card present FLASHING j RAPIDLY CompactFlash card being checked Unit is writing t
6. 4X IP66 aluminum front plate when correctly fitted with the gasket provided Installation Category I Pollution Degree 2 10 MOUNTING REQUIREMENTS Maximum panel thickness is 0 25 6 3 mm For NEMA 4X IP66 sealing a steel panel with a minimum thickness of 0 125 3 17 mm is recommended Maximum Mounting Stud Torque 17 inch pounds 1 92 N m 11 WEIGHT 1 96 lbs 0 89 Kg 6 04 153 4 J o f 1 800 237 8274 Lakeland FL Lawrenceville GA Greensboro NC East Rutherford NJ 2 www A AElectric com INSTALLING AND POWERING THE G303 USER IDENTIFIABLE KEYS The G303 unit comes with a pre printed key strip inserted This key strip is labeled F1 through F8 and corresponds to Crimson software If desired these keys may be custom labeled for specific functions The default key strip may be removed and a custom key strip inserted Each unit is delivered with two sheets of white Cover 65 paper This 8 2 x11 paper may be used with most copiers jet printers or laser printers REMOVE PANEL GASKET BEFORE REMOVING OR INSERTING KEY STRIPS Custom key strips are made easily using the Adobe Acrobat file available from www redlion net or included with each Crimson CD This program allows users to enter custom text and color schemes If more customization is needed a graphics package can be used The key strip dimensions are a
7. EMORY 4 MBYTE FLASH COMPACTFLASH SOCKET TO INCREASE MEMORY CAPACITY 3 2 INCH 128X64 PIXEL LCD WITH YELLOW LED BACKLIGHT ABLE TO SUPPORT TEXT AND SIMPLE GRAPHICS OUTDOOR UNIT WITH UV RATED OVERLAY AVAILABLE 32 BUTTON KEYPAD WITH USER IDENTIFIABLE KEYS NAVIGATIONAL KEYS NUMERIC KEYS KEYS FOR ON SCREEN MENUS AND OTHER VARIOUS KEYS C THREE FRONT PANEL LEDS POWER UNIT FROM 24 VDC 20 SUPPLY CONTENTS OF PACKAGE G303 Operator Interface Panel gasket Two user legendable key sheets Template for panel cutout Hardware packet for mounting unit into panel Terminal Block for connecting power ORDERING INFORMATION MODEL NO DESCRIPTION PART NUMBER Operator Interface for indoor applications only textured finish with embossed keys analog Operator Interface for indoor or outdoor applications glossy finish with UV rated overlay keys are not embossed 64 MB CompactFlash Card 5 256 MB CompactFlash Card 5 512 MB CompactFlash Card 5 RS232 485 Optional Communications Cards CANopen Optional Communications Cards DIN Rail Power Supply Crimson 2 0 2 RS 232 Programming Cable USB Cable Communications Cables 1 DIN Rail Mountable Adapter Products 3 G303S000 G3CF064M G3CF256M G3CF512M G3RS0000 G3CNO0000 PSDR7000 SFCRM200 CBLPROGO CBLUSBOO G3RS G3CN PSDR7 SFCRM2 DRxxxxxx BAL3R004 LBAFLM02 G3FILM G3FILM03 Contact your Red Lion distributor or visit our website for compl
8. FOR INSTALLATION WITHIN THE UNITED STATES OR AS SPECIFIED IN SECTION 19 152 OF CANADIAN ELECTRICAL CODE FOR INSTALLATION IN CANADA CONNECTING TO EARTH GROUND Each G303 has a chassis ground terminal on the back of the unit Your unit should be connected to earth ground protective earth The chassis ground is not connected to signal common of the unit Maintaining isolation between earth ground and signal common is not required to operate your unit But other equipment connected to this unit may require isolation between signal common and earth ground To maintain isolation between signal common and earth ground care must be taken when connections are made to the unit For example a power supply with isolation between its signal common and earth ground must be used Also plugging in a USB cable may connect signal common and earth ground 1 USB s shield may be connected to earth ground at the host USB s shield in turn may also be connected to signal common POWER SUPPLY REQUIREMENTS The G303 requires a 24 VDC power supply rated at 9 5 W Your unit may draw considerably less than 9 5 W depending upon the options being used As additional features are used your unit will draw increasing amounts of power Items that could cause increases in current are additional communications optional communications card Compact Flash card and other features programmed through Crimson In any case it is very important that the power supply
9. TE For reliable operation in all of our products Red Lion recommends the use of SanDisk and SimpleTech brands of CompactFlash cards Industrial grade versions that provide up to two million write erase cycles minimum are available from Red Lion LIMITED WARRANTY The Company warrants the products it manufactures against defects in materials and workmanship for a period limited to two years from the date of shipment provided the products have been stored handled installed and used under proper conditions The Company s liability under this limited warranty shall extend only to the repair or replacement of a defective product at The Company s option The Company disclaims all liability for any affirmation promise or representation with respect to the products The customer agrees to hold Red Lion Controls harmless from defend and indemnify RLC against damages claims and expenses arising out of subsequent sales of RLC products or products containing components manufactured by RLC and based upon personal injuries deaths property damage lost profits and other matters which Buyer its employees or sub contractors are or may be to any extent liable including without limitation penalties imposed by the Consumer Product Safety Act P L 92 573 and liability imposed upon any person pursuant to the Magnuson Moss Warranty Act P L 93 637 as now in effect or as amended hereafter No warranties expressed or implied are created w
10. e G303S000 uses an overlay with a glossy finish that uses a UV rated material for outdoor use The keys on this overlay are not embossed OPTIONAL COMMUNICATION CARD Red Lion offers optional communication cards for fieldbus communications These communication cards will allow your G303 to communicate with many of the popular fieldbus protocols Red Lion is also offering a communications card for additional RS232 and RS422 485 communications Visit Red Lion s website for information and availability of these cards CUSTOM LOGO Each G3 operator interface has an embossed area containing the Red Lion logo Red Lion can provide custom logos to apply to this area Contact your distributor for additional information and pricing S Sa N51 13 I FRONT OVERLAY COMPACTFLASH SOCKET CompactFlash socket is a Type II socket that can accept either Type I or II cards Use cards with a minimum of 4Mbytes with the G303 s CompactFlash socket Cards are available at most computer and office supply retailers CompactFlash can be used for configuration transfers larger configurations data logging and trending Note Do not remove or insert the CompactFlash card while power is applied Refer to front panel LEDs CompactFlash Insert Face Up Information stored on a CompactFlash card by a G303 can be read by a card reader attached to a PC This information is stored in IBM Windows PC compatible FAT 16 file format NO
11. e key numeric keypad with and decimal point Three soft keys for on screen menu selections And four keys labeled ALARMS MUTE EXIT and MENU TROUBLESHOOTING YOUR G303 If for any reason you have trouble operating connecting or simply have questions concerning your new G303 contact Red Lion s technical support For contact information refer to the back page of this bulletin for phone and fax numbers EMAIL techsupport redlion net Web Site http www redlion net sold by AA Electric 1 800 237 8274 Lakeland FL Lawrenceville GA Greensboro NC East Rutherford NJ www A AElectric com BATTERY amp TIME KEEPING WARNING EXPLOSION HAZARD THE AREA MUST BE KNOWN TO BE NON HAZARDOUS BEFORE SERVICING REPLACING THE UNIT AND BEFORE INSTALLING OR REMOVING I O WIRING AND BATTERY WARNING EXPLOSION HAZARD DO NOT DISCONNECT EQUIPMENT UNLESS POWER HAS BEEN DISCONNECTED AND THE AREA IS KNOWN TO BE NON HAZARDOUS A battery is used to keep time when the unit is without power Typical accuracy of the G303 time keeping is less than one minute per month drift The battery of a G303 unit has no affect on the unit s memory as all configurations and data are stored in non volatile memory CAUTION The circuit board contains static sensitive components Before handling the operator interface without the rear cover attached discharge static charges from your body by touching a grounded bare metal object Ideally handl
12. e only using Type B connection Ww Nn nN WARNING DO NOT CONNECT OR DISCONNECT CABLES WHILE POWER IS APPLIED UNLESS AREA IS KNOWN TO BE NON HAZARDOUS USB PORT IS FOR SYSTEM SET UP AND DIAGNOSTICS AND IS NOT INTENDED FOR PERMANENT CONNECTION Serial Ports Format and Baud Rates for each port are individually software programmable up to 115 200 baud PGM Port RS232 port via RJ12 COMMS Ports RS422 485 port via RJ45 and RS232 port via RJ12 These two ports share the same hardware the G303 multiplexes the ports to communicate via two protocols These ports may be used to configure different master protocols but only one port may be used if configuring a slave protocol or AB DH485 DH485 TXEN Transmit enable open collector Voy 15 VDC Vor 0 5 V 25 mA max Note For additional information on the communications or signal common and connections to earth ground please see Connecting to Earth Ground in the section Installing and Powering the G303 Ethernet Port 10 BASE T 100 BASE TX RJ45 jack is wired as a NIC Network Interface Card ENVIRONMENTAL CONDITIONS Operating Temperature Range 0 to 50 C Storage Temperature Range 30 to 70 C Operating and Storage Humidity 80 maximum relative humidity non condensing from 0 to 50 C Altitude Up to 2000 meters N DIMENSIONS In inches mm 7 45 189 2 sold by AA Electric 8 CERTIFICATIONS
13. e the operator interface at a static controlled clean workstation Also do not touch the surface areas of the circuit board Dirt oil or other contaminants may adversely affect circuit operation To change the battery of a G303 remove power cabling and then the rear cover of the unit To remove the cover remove the four screws designated by the arrows on the rear of the unit Then by lifting the top side hinge the cover thus providing clearance for the connectors on the bottom side of the PCB as shown in the illustration below Install in the reverse manner Remove the old battery from the holder and replace with the new battery Replace the rear cover cables and re apply power Using Crimson or the unit s keypad enter the correct time and date Please note that the old battery must be disposed of in a manner that complies with your local waste regulations Also the battery must not be disposed of in fire or in a manner whereby it may be damaged and its contents come into contact with human skin The battery used by the G303 is a lithium type CR2025 BATTERY sold by AA Electric 1 800 237 8274 Lakeland FL Lawrenceville GA Greensboro NC East Rutherford NJ www A AElectric com OPTIONAL FEATURES AND ACCESSORIES INDOOR VERSUS OUTDOOR Red Lion offers two versions of its G303 unit The G303M000 uses an overlay with a textured finish and keys that are embossed This overlay is not rated for outdoor use Th
14. ete selection 2 Use this part number to purchase Crimson on CD with a printed manual USB cable and RS 232 cable Otherwise download from www redlion net 3 Red Lion offers RJ modular jack adapters Refer to the DR literature for complete details 4 Battery type is lithium coin type CR2025 5 Industrial grade two million write cycles Replacement Battery 4 Key Strip Paper Protective Films 1 800 237 8274 Lakeland FL Lawrenceville GA Greensboro NC East Rutherford NJ www A AElectric com SPECIFICATIONS POWER REQUIREMENTS 24 VDC 20 9 5 W maximum Must use Class 2 or SELV rated power supply Power connection via removable three position terminal block Notes 1 The front panel PWR LED indicates power 2 The G303 s circuit common is not connected to the enclosure of the unit See Connecting to Earth Ground in the section Installing and Powering the G303 2 BATTERY Lithium coin cell Typical lifetime of 10 years DISPLAY 3 2 128 x 64 pixel FSTN LCD with yellow LED backlight for characters and simple graphics applications 4 32 KEY KEYPAD 8 user legendable keys 5 navigational keys 10 2 numeric keys 4 dedicated keys and 3 soft keys for on screen menus MEMORY On Board User Memory 4 Mbyte of onboard non volatile Flash memory Memory Card CompactFlash Type II slot for Type I and Type IL CompactFlash cards COMMUNICATIONS USB Port Adheres to USB specification 1 1 Devic
15. is mounted correctly if the unit is to operate reliably Please take care to observe the following points The power supply must be mounted close to the unit with usually not more than 6 feet 1 8 m of cable between the supply and the operator interface Ideally the shortest length possible should be used The wire used to connect the operator interface s power supply should be at least 22 gage wire If a longer cable run is used a heavier gage wire should be used The routing of the cable should be kept away from large contactors inverters and other devices which may generate significant electrical noise A power supply with a Class 2 or SELV rating is to be used A Class 2 or SELV power supply provides isolation to accessible circuits from hazardous voltage levels generated by a mains power supply due to single faults SELV is an acronym for safety extra low voltage Safety extra low voltage circuits shall exhibit voltages safe to touch both under normal operating conditions and after a single fault such as a breakdown of a layer of basic insulation or after the failure of a single component has occurred 1 800 237 8274 Lakeland FL Lawrenceville GA Greensboro NC East Rutherford NJ www A AElectric com COMMUNICATING WITH THE G303 CONFIGURING A G303 The G303 is configured using Crimson software Crimson is available as a free download from Red Lion s website or it can be ordered on CD Updates to Cri
16. ith respect to The Company s products except those expressly contained herein The Customer acknowledges the disclaimers and limitations contained herein and relies on no other warranties or affirmations Red Lion Controls 20 Willow Springs Circle York PA 17402 Tel 1 717 767 6511 Fax 1 717 764 0839 Red Lion Controls BV Basicweg 11b NL 3821 BR Amersfoort Tel 31 0 334 723 225 Fax 31 0 334 893 793 Red Lion Controls AP 31 Kaki Bukit Road 3 06 04 05 TechLink Singapore 417818 Tel 65 6744 6613 Fax 65 6743 3360 sold by AA Electric 1 800 237 8274 Lakeland FL Lawrenceville GA Greensboro NC East Rutherford NJ www A AElectric com
17. mson for new features and drivers are posted on the website as they become available By configuring the G303 using the latest version of Crimson you are assured that your unit has the most up to date feature set Crimson software can configure the G303 through the RS232 PGM port USB port or CompactFlash The USB port is connected using a standard USB cable with a Type B connector The driver needed to use the USB port will be installed with Crimson The RS232 PGM port uses a programming cable made by Red Lion to connect to the DB9 COM port of your computer If you choose to make your own cable use the G303 Port Pin Out Diagram for wiring information The CompactFlash can be used to program a G3 by placing a configuration file and firmware on the CompactFlash card The card is then inserted into the target G3 and powered Refer to the Crimson literature for more information on the proper names and locations of the files CABLES AND DRIVERS Red Lion has a wide range of cables and drivers for use with many different communication types A list of these drivers and cables along with pin outs is available from Red Lion s website New cables and drivers are added on a regular basis If making your own cable refer to the G303 Port Pin Outs for wiring information USB DATA TRANSFERS FROM THE COMPACTFLASH CARD WARNING DO NOT CONNECT OR DISCONNECT CABLES WHILE POWER IS APPLIED UNLESS AREA IS KNOWN TO BE NON HAZARDOUS USB PORT IS
18. o the CompactFlash either because it is storing FLICKERING data or because the PC connected via the USB port has locked the drive FLASHING SLOWLY Incorrectly formatted CompactFlash card present GREEN BOTTOM FLASHING Atag is in an alarm state STEADY Valid configuration is loaded and there are no alarms present 1 The operator interface is shipped without a configuration After downloading a configuration if the light remains in the flashing state continuously try cycling power If the LED still continues to flash try downloading a configuration again 2 Do not turn off power to the unit while this light is flickering The unit writes data in two minute intervals Later Microsoft operating systems will not lock the drive unless they need to write data Windows 98 may lock the drive any time it is mounted thereby interfering with logging Refer to Mounting the CompactFlash in the Crimson 2 User Manual Unit is powered and running an application CRIMSON SOFTWARE Crimson software is available as a free download from Red Lion s website or it can be purchased on a CD see Ordering Information for part number The latest version of the software is always available from the website and updating your copy is free KEYPAD The G303 keypad consists of five unique key types There are eight legendable keys refer to User Legendable Keys for more information A five key navigational keypad area A twelv
19. on pa NN BBH Mor NNH SS GOERE mira t OOOO eo z394 85 SEES Application Dependent App P ve PS PaCS wa E i 66 LI 1 CBLPROGO can also be used to communicate with either a PC or an ICMS 2 DB9 adapter not included 1 foot long 3 DB9 adapter not included 10 feet long 1 800 237 8274 Lakeland FL Lawrenceville GA Greensboro NC East Rutherford NJ www A AElectric com G303 PORT PIN OUTS PROTECTIVE EARTH GROUND YELLOW RTS PIN 6 TxA PIN 8 RTS PIN 6 LED COMM COMM Tx TxA RxA RxB TxEN COMM TxB Rx COMM COMM Tx CTS PIN 1 Rx PIN 1 cTS PIN 1 COMMON 2 24V 20 RS232 see RS232 ETHERNET NIC POWER PGM PORT COMMS COMMS CONNECTOR PORT PORT RS422 485 COMMS PORT Examples of RS485 2 Wire Connections The G303 has one RS422 485 port This port can be configured to act as either RS422 or RS485 G3 to Red Lion RJ11 CBLRLC00 The RS422 485 COMMS and RS232 COMMS ports are multiplexed DLC IAMS ITMS PAXCDC4C because they share the same hardware Both COMMS ports can be used with master protocols However when the RS422 485 COMMS port is used with a Connections slave protocol the RS232 COMMS port is not available G3 RJ45 RLC RJ11 RS422 485 4 WIRE RS485 2 WIRE CONNECTIONS CONNECTIONS 3 5v 5 130K 7 4 TB
20. red lion Tel 1 717 767 6511 Fax 1 717 764 0839 www redlion net Bulletin No G303 Drawing No LP0561 Released 4 06 MODEL G303 GRAPHIC LCD OPERATOR INTERFACE TERMINAL 7 Beis 00o oon EI Rj ce x W Rx FOR USE IN HAZARDOUS LOCATIONS Class I Division 2 Groups A B C and D Class II Division 2 Groups F and G Class III Division 2 c US LISTED 63YN LABORATORY EQUIPMENT GENERAL DESCRIPTION The G303 Operator Interface Terminal combines unique capabilities normally expected from high end units with a very affordable price It is built around a high performance core with integrated functionality This core allows the G303 to perform many of the normal features of the Paradigm range of Operator Interfaces while improving and adding new features The G303 is able to communicate with many different types of hardware using high speed RS232 422 485 communications ports and Ethernet 10 Base T 100 Base TX communications In addition the G303 features USB for fast downloads of configuration files and access to trending and data logging A CompactFlash socket is provided so that Flash cards can be used to collect your trending and data logging information as well as to store larger configuration files In addition to accessing and controlling of external resources the G303 allows a user to easily view and enter information The unit uses a Liquid Crystal Display LCD module which is easily readable in both indoor and
21. s follows 4 00 101 6 E hh E 1 I 11 44 dl J 1 075 27 3 a R 100 a f it lio VISIBLE AREA OF a 76 2 When inserting the key strip into the slot in the G303 panel start one corner first then slowly insert the strip into place Note Key strips need to be inserted into the unit before mounting into a panel CHAMFER 2 PLCS 675 FOR EASIER INSERTION 17 1 MOUNTING INSTRUCTIONS This operator interface is designed for through panel mounting A panel cut out diagram and a template are provided Care should be taken to remove any loose material from the mounting cut out to prevent that material from falling into the operator interface during installation A gasket is provided to enable sealing to NEMA 4X IP66 specification Install the eight kep nuts provided and tighten evenly for uniform gasket compression Note tightening the kep nuts beyond a maximum of 17 inch pounds 1 92 N m may cause damage to the front panel _ 6 875 174 6 6 25 158 8 Va BX 9 188 04 8 i T T 5 275 134 4 625 117 5 ij All tolerances 0 010 0 25 mm sold by AA Electric 3 ALL NONINCENDIVE CIRCUITS MUST BE WIRED USING DIVISION 2 WIRING METHODS AS SPECIFIED IN ARTICLE 501 4 b 502 4 b AND 503 3 b OF THE NATIONAL ELECTRICAL CODE NFPA 70
Download Pdf Manuals
Related Search
Related Contents
ABBYY ScanTo Office HASBRO 030901693061Ab User's Manual IHD User Manual - PLANET Technology Corporation. descargar manual Samsung Samsung C6620 User Manual Intenso 16GB Basic USB2.0 Audiovox LCM7070 User's Manual Excel 10 Owners Manual Samsung MX-J630 Manual de Usuario Copyright © All rights reserved.