1. 000 120defense zone Query the type and siren setting of certain wireless defense zone Example Send message 123460001 to the alarm panel the alarm panel replies 001 zone is wireless zone zone type normal siren ON Query the alarm panel for settings of zone 051 052 wired zone Example send text message 123461051 to the alarm panel the alarm panel replies 051 zone is wired zone zone type normal siren ON alarm type NO Query the alarm panel the phone number assigned to zone 000 120 ample send message 1234630014 to the alarm panel the arm panel replies 001 zone dialing group number 123456 ns zone 1 will dial phone group 123456 sed to customize the SMS message for zone 000 120 123480001 Front Door Alarm rm panel will set alarm panel to send SMS message to the Front mple Send message Door Alarm upon zone 0l alarm being triggered ote Maximum length of message is 25 characters Query zone 000 120the content of SMS message customized Example Send 123481001 to the alarm panel to query for zone Ol message content Note 1234 string shown above table all represents the password User can change password and thus should adjust the commands listed accordingly 4 4 Call up call charges inquiry Call up Syntax 0 0 phone number This machine can be used as a mobile for conversation To do that on the keyboard put in 0013712345678 wher
2. Method three Send SMS message 12341514 Turn on or off Interference Alert Syntax 16 0 1 This set the alarm panel to sound for 5 seocnds upon a kind of malicious attach from un authorized remote control or transmitter of same frequency meanwhile the alarm panel will Exa display tP warning 1 means on 0 means off ple users need enable interference alert Method one and then press 161 press and to Exit Setup Method two After calling and connected to the panel from remote press 161 Method three Send SMS message1234161 Keyboard password protection Syntax 17 0 1 To enable the password protect of keyboard System default password is 1234 default is off Alarm panels will display Key lock when keyboard is locked Example keyboard users need to set the password protection Method one and then press 171 press and to Exit Setup Method two After calling and connected to the panel from remote press 171 Method three Send SMS message 12341714 Alarm linkage function on or off Syntax 20 0 1 Enable or disable the alarm linkage function 1 is enabled and 0 is disabled the system default is l Example users need to set the alarm linkage function off Method one and then press200 press and to Exit Setup Method two After calling and connected to the panel from remote press 200 Meth
3. then press to exit the query mode Query the time for Query delay time for arm 00 99 Seconds delay arm Press alarm panel query key of your keyboard and then press Syntax 51 51 the alarm panel LED show 00 mean time for delay is 0 second Query delay time for alarming To query the alarm delay time 00 99 Seconds Press alarm panel query key of your keyboard and then press 15 Syntax 52 press 52 the alarm panel LED show 00 mean time for delay is 0 second Query siren sounding time for alarming Syntax 53 To query the siren sounding time 00 20 minutes when the alarming Press alarm panel query key of your keyboard and then press 53 the alarm panel LED show 01 mean time for delay is 1 minute Query remote control For query of specific remote control and keyboard and keyboard assignments to zone 000 120 assignments to zone Syntax 54 000 120 Press alarm panel query key of your keyboard and then press 5401 the alarm panel LED show 000 120 and remote control l means remote control 1 is controlling zone 000 120 press clear screen using 54024 for query remote control 2 and so on Query remote control audible confirmation Syntax 55 000 120 For query the setting of remote control 000 120 for the audible confirmation to command ON means sound OFF means without sound present keyboard Pre
4. scheduled arm and disarm Example To set up the first group scheduled arm and disarm control 00 50 defense zone Method one Press enter the setup status and press 5801000050 press then press exit Setup Method two After calling and connected to the panel from remote press 5801000050 Method three Send SMS messagel12345801000050 Set the type of To set 120 zone type 000 120 represents 0 120zone number defense zone 1 8 represents one of the 8 zone type Syntax 1 NORMAL K 60 2 STAY ARM 000 120 zone 3 INTELLIGENT number J 1 8 4 EMERGENCY Type 0 1 5 CLOSED 6 CHIME 7 WELCOME 8 HELP SENIOR The last 0 1 represents 0 siren of panel produce no sound upon alarming while 1 is sounded Example Set zone number 2 as STAY zone type and siren not sound upon alarming Method one Press enter the configuration mode press 6000220 press then press To exit Setup Method two After calling and connected to the panel from remote press 6000220 Method three Send SMS message 12346000220 Set mode of wired Set wired alarm zone to NO or NC The zone number of 051 052 alarm zone are wired defense zones system default is 051 052 are wired 11 Syntax 61 zone number 051 052 3 0 1 zones with NO mode 0 means NO and 1 means NC NO means short circuit to alarm NC means open circuit to alarm Example Set 051 zone to NC Method one P
5. time of arm BBBB Scheduled time Number of week disarmed To set the time for scheduled arm and disarm it allows set at most four group of time for arm and disarm Example set up the first group scheduled time toarm at 22 00 pm and disarm at 07 00 am this is valid for Monday Tuesday Wednesday Thursday and Friday of each week Method one Press enter the configuration mode and then press 57012200070012345 Example set up the second group scheduled time to arm at 12 00 and disarm at 13 00 pm this is valid for all 7 days of each week Method one Press enter the configuration mode and then press 5702120013001234567 then press to exit Setup Method two After calling and connected to the panel from remote press 57012200070012345 then press5702120013001234567 Method three Send SMS message 123457012200070012345 and 12345702120013001234567 Delete the scheduled arm disarm time setting Syntax 57 Group number 01 04 0 To delete the time of scheduled arm and disarn Example delete the first group time of scheduled arm disarm Method one Press enter the configuration mode and then press 57010 Method two After calling and connected to the panel from remote press 57010 Method three Send SMS message 123457010 Scheduled clock time setting To set the alarm time when alarm sound can press any button of the keyboard or press t
6. ARM The system is at a fully ready status where all detectors are activated in a working state when the some events burglar fire gas leak etc happened and detected alarm system alarm right away In a ARM status the panel light ARM is on the screen show BF for 1s To activate using remote control press jg key once To activate using keyboard on panel press lkey once STAY ARM This is for partial arming of the alarm system when there are people at home only some of the selected sensors are activated and could be triggered by events Ina STAY ARM status the arming LED on the panel is lighting every two seconds and at the same time showing LB on the screen for one second To activate using remote control press S key once 2 DISARM All sensors are deactivated and will not be respond to any events In a DISARM status the panel DISARM light is off at the same time shows CF for one second onthe display m To activate using remote control press a J key once To activate using keyboard on panel keyboard a 7 keys once EMERGENCY When an emergency occurs press emergency button on the remote or the SOS button on panel to activate alarm Remark If password on keyboard is enabled you need to enter password before other operations the initial password is 1234 2 2 System Components and Usage 2 2 1 Panel Setup Alarm panel should be installed at a central location with best transmis
7. calling and connected to the panel from remote press 52608 Method three Send SMS message 12345260 Set length of Siren sound Syntax 53 00 20 Minutes Set alarm length of sounding when panel alarm could be set to 0 20 minutes factory default is 1 minute Example you want to make a siren sound 5 Minutes Method one Key to enter the configuration mode press the 5305 Then press To exit Setup Method two After calling and connected to the panel from press 5305 Method three Send SMS messages12345305 remote Set the control of alarm panel scope of and remote control Syntax 54 Remote control number 000 120 Starting defense area 000120 End of defense zone 000120 C Set which defense zone will be controlled by remote control and from alarm panel keyboard Factory default is all remote control and keyboard can control all 000 120 zones Remark The 1 represents the alarm panel keyboard remote control represented by number Ol Example you want to set Ol remote control to control only 00 20 zone Method one Key to enter the configuration mode press 54010020 Example you want to set the alarm panel keyboard control 00 50 Defense zone Method one Key to enter the configuration mode press 54 0050 then Method two press To exit Setup After calling and connected to the panel from r
8. matter Zone in what status the panel will alarm once sensor with this zone type is triggered 6 2 System default zone types are Intelligent _ Help Senior 01 59 100 12 0 60 79 80 89 6 3 Other System Default 91 92 93 99 Operation 1234 password Remote Control Enable Power saving Enable Siren sound Iminute Audible confirmation for remote operation Enable Delay ARM Os Delay alarming Os Siren volume 99 0 120zone alarm Siren 22 sound Alarm linkage Enable 51 52 wired zone alarm type NO SMS message Enable 1 120Zone SMS message content Zone alarm 6 4 Fitting parameters Input voltage DC9V 12V Standby currents lt 25 mA Alarm current lt 450 mA E Wireless frequency 315 433 868 915MHZ GSM Format Support GSM850 900 1800 1900MHz option E Backup battery NI HI AAA 6 DC7 24V E Alarm loudness 110dB 2262 1 5 4 7M_ EV1527 300K Detailed parameters The alarm should be compatible with PT2262 PT2240 and EV1527 Using PT2262 encoding the resistance is recommended 1 5M 3M using with EV1527 encoding the resistance by 170K data recommended 1010 23
9. telephone alarm number Method one After you press the key to enter the configuration mode press the 31 Method two After entering the telephone remote setting status press 314 Method three Send SMS message 123431 On the alarm panel alarm panel reply then press then press to exit Setup Group 1 phone number to confirm the 1st group alarm phone number has been removed Set phone number to receive SMS message Syntax 4 1 6 Phone number C To set the first group to the sixth group of phone number for SMS message When alarm panel is alert it sends a SMS message to the six sets of numbers one by one Example If the user wants to set 13812345678 SMS for the first group of SMS message Method one After press the key to enter the configuration mode press the 4113812345678 Method two After calling and connected to the panel from remote press 4113812345678 Method three Send SMS message 12344113812345678 to the panel then press then press Exit Setup Delete SMS phone number Syntax 4 1 6 Used to delete the first group to SMS of the sixth group police number Example If you want to delete the first set of SMS message phone number Method one After you press the key to enter the configuration mode press the 41 Method two After calling and connected to the panel from remote then press then press Exit
10. use 006 instead of 001 Upon completion press to exit the configuration modeof delete the detector press and then exit the configuration mode 4 Command Reference This system supports three methods of configuration including the local keyboard telephone set and SMS messaging Following are examples how instructions are given via one of the three methods of setting Example you want to change the first phone number for voice calling to 13899998888 Method 1 At the Keyboard Press to enter the configuration mode and then press 3113899998888 press the then press to exit configuration mode Method 2 By telephone set Calling into the alarm panel upon connected alarm panel will ask for password it is 1234 as the default then press and then press 3113899998888 press the then press to exit configuration mode Method 3 Using SMS On your mobile phone compose a SMS message as 12343113899998888 and send to your alarm panel Remark The status LED is light on the panel to indicate at the configuration mode the status light is off upon exit Below is a table of all commands supported 4 1 Commands for Configuration Set up voice alarm To set the lst group to the 9th group of voice alarm phone phone number number 1 9 indicates that the first group to the Nineth group alarm number correspondingly Syntax Example If the user wants to set 13812345678 for the first 3
11. 1 9 set of voice alarm phone number Phone number Method one After you press the key to enter the configuration mode press the 3113812345678 press Then press To exit Setup Method two Remote calling into the alarm panel put in password initial password 1234 when being asked then press the key hear the voice prompt means the host into setting state In remote setting press a digital then the host will broadcast one digital speech if press a digital not broadcast speech or press once broadcast second speech mean setting not correct Press key to exit Method three Send SMS messages 12343113812345678 to a alarm panel which at the beginning of 1234 is the user password the alarm panel will reply with SMS message Group 1 phone number 13812345678 to confirm the Ist group alarm phone number is set to13812345678 successfully For users using the telephone line extension you should dial a number such as 9 to pick up a dialing tone then with your command you should add to this number a So the completed command becomes 9 13812345678 Remark 7 8 9 group number for HELP SENIOR zone and panel will only dial these three groups number when that specific zone alarming Delete voice alarm phone number Syntax 3 1 9 Used to delete the first groups to the Nineth group alert phone numbers Example If you want to delete the first set of
12. F Query sound volume of siren Syntax 14 Query for the volume level of siren it shows between 00 99 representing the 00 as lowest and 99 as highest volume Query for the setting of enforced keyboard disarm Syntax 15 To query whether enforcing the disarm from keyboard upon alarming It shows either ON or OFF Query of the setting of interference alert Syntax1l6 To query whether interference alert is set it shows either ON or OFF Query keyboard password protection Syntax 17 To query if the password protection feature is enabled it shows either ON or OFF Query the setting of alarm linkage Syntax 20 For query the setting of alarm linkage function It shows either ON or OFF Query alarm panel arm disarm records Syntax 9901 The system can save up to the most recent 72 disarmed records Press alarm panel query key of your keyboard and then press 9901 press 8 to scroll up and 0 to scroll down for records Other indications as 0801 means date Ist August 17 1210 means time is 12 10 JP arm disarm from keyboard YC arm disarm from remote DS Scheduled arm disarm YK arm disarm from remote control CF disarm BF arm tP interference alert 01 remote control number 1 Remark if first display DS and then show 01 02 03 04means 4 groups of scheduled arm disarm Query alarm p
13. LIGENT 4 means EMERGENCY 5 means CLOSED 6 means CHIME 7 means WELCOME 8 means HELP SENIOR The word ON or OFF siren will sound upon alarming next to the zone type represents whether 16 Query the type of wired zones Syntax 61 051 052 4 For query the zone type of 51 52 Example Press alarm panel query key of your keyboard and then press 61051 to query 51 zone alarm type show NO means short circuit to alarm while show NC means open circuit to alarm Query remote operation on off Syntax 62 To query if the remote operation is allowed it should show either ON or OFF Query phone number for specific zone Syntax 63 000 120 To query the phone number assigned to zone 000 120 for alert Example Press alarm panel query key of your keyboard and then press 63001 for zone 1 the alarm panel LED show 123456 means these 6 group of phone numbers are assigned to 01 zone Query the power saving mode on or off Syntax 84 To query the power saving mode on or off It shows either ON or OFF Query for the setting of alarm audible confirmation Syntax 11 For query whether the alarm will play audible confirmation upon receipt of commands It shows either ON or OFF Query the SMS messaging function on or off Syntax 12 For query the SMS messaging function on off It shows either ON or OF
14. Security GSM Alarm System USER MANUAL Security GSM Alarm System ICIS SISIE Osacae 1 Introduction 1 1 General Description This GSM system with 120wireless zones and digital clock display is suitable for both home and commercial use It uses the advanced GSM digital signal process technology GSM Wireless intelligent alarm systemlIt has highly integrated digital voice SMS self learning wireless communication code remote appliance control and text messaging technologies It is a choice of stability reliability security and user friendliness Features are very practical cost effective completed configuration and ease of use This alarm can integrate with a lot of alarm accessories including door sensor smoke detectors gas detectors emergency buttons and other accessories to build a powerful security setup It has been widely used in homes factories schools shops convenience stores financial and banking workplace community centre and residential area to provide protection to valuable assets 1 2 System Features Digital clock display with two groups alarm function time optional Support GSM mobile network provide redundancy for extra stability Allow up to 120 wireless defense zones and 2 wired zones Each can be defined as one of the 8 zone types including NORMAL STAY INTELLIGENT EMERGENCY CLOSED HELP SENIOR WELCOME and CHIME Four sets of scheduled arm disarmed function each time you ca
15. Setup press41 Method three Send SMS messagel23441 Password modification Syntax 50 4 digits new password Used to modify the user password the default user password is 1234 Exa ple If you want to set up a new user password 4321 Method one Press key to enter the configuration mode press the 5043214 press the then press to exit setup Method two After calling and connected to the panel from remote press 504321 Method three Send SMS message 1234504321 Set delay for system arm Syntax 51 _ 00 99 Second Upon armed from the remote control or alarm panel the alarm panel is set to delay 0 99 before at the ready status of ARM The system default is 00 seconds Example users need to set the delay time for 60 Seconds Method one Press key to enter the configuration mode press the 5160 then press then press to exit setup Method two After calling and connected to the panel from remote press 5160 Method three Send SMS messages12345160 Set the time of delay for alarming Syntax 52 00 99 Second Set the time of delay upon alram it can be set to 0 99 seconds the system default is 00 seconds Example the user needs to set the alarm delay time to 60 Seconds Method one Press Key to enter the configuration mode press the 5260 and press then press to exit setup Method two After
16. anel alarming records Syntax 9900 The system can save up to the most recent 102 alarming records Press alarm panel query key of your keyboard and then press 9900 press 8 to scroll up and 0 to scroll down for records Example Screen shows 08 01 12 10 01 alarm which means alarm happened on 12 10 am 1 August at zone 01 Query the arm district Syntax 00 For query the arm district Press alarm panel query key of your keyboard and then press 00 LCD show 000 120 means defence zone 000 120 is arming 4 3 SMS Commands The following instructions are only for SMS command to control panel remotely S disarm O S NORMAL arm 1 S STAY arm 2 ote SMS turn on relay 3H ote SMS turn off lay 4 Query the AC power status 6 Send SMS message 12340 into alarm panel Note 1234 is the password Send SMS messages 12341 to set the alarm panel to ARM Send SMS message 12342 to set alarm panel to STAY ARM Send SMS message 12343 to turn on the relay of the alarm panel Send SMS messages 12344 to turn off the relay of the alarm panel Send SMS messages 12346 to the alarm panel the alarm panel replies AC power ON or AC power OFF Query the alarm panel general settings 11 Query voice alarm phone number 30 01 09 Query phone number for SMS message 40 01 06 Query assignmen
17. e 13712345678 is the phone number you re going to connect At the end of your call press DISARM key press and then press to exit Call charges inquiry 20 Example If use China Mobile GSM SIM card dial 13800138000 to query the call charges Syntax press 0013800138000 1 2 press disarm button of the alarm panel to hang up and press to exit The enquiry hotline is different according to your GSM SIM card 4 5 SMS reminder Example user s phone number 13788888888add it as the first group SMS alarm number Press 4113788888888 last press and then press to exit When AC power is off the alarm system would send SMS message to this number And AC power is on the panel also send the SMS message to the user Remark If you disable the SMS message function or not set the SMS alarm number this function will auto off 5 Remote Control of Panel 5 1 After receiving the Panel Alert After Panel alerts it will automatically dial the preset telephone number for three times until connected and send SMS message to the preset telephone number When the user picks up the phone a piece of pre recorded voice message will be played back immediately and let the receiver noted about the event Upon receiving the call it can also control the alarm panel remotely via the phone according to the command below User will not be asked for password upon connected and alarm will automatically hang up call within receivi
18. el beep twice means successful beep only once means the remote control has been configured before Alarm panel can configure up to 150 remote control of different addressing Upon completion press to exit the configuration mode press and then exit the configuration mode 3 4 Delete the remote control Press Key to enter the configuration mode e Syntax 1 08 000 120 to delete the remote control e Syntax 2 08 to delete all remote controls Example 08 then press 001 for deleting Ist remote control then if you want to delete 8th remote control press 008 instead of 001 Press to exit the configuration mode of delete remote control press and then to exit configuration mode 3 5 Add detector Press Key to enter the configuration mode Syntax 09 000 120 to configure the detector Example 09 then press 001 to configure Ist sensor then trigger the detector to send a signal to the alarm panel panel beep twice means successful beep only once means the remote control has been configured before Alarm panel can configure up to 150 sensors of different addressing Upon completion press to exit the configuration mode press and then exit the configuration mode 3 6 Delete detector Press Key to enter the configuration mode Syntax 1 10 000 120 to delete the detector Syntax 1 10 to delete all detectors Example 10 then 001 to deleting Ist sensor If you want to delete the 6th detectors
19. emote press 54010020 then press 54 xx0050 Method three Send SMS 123454 x0050 message 123454010020 and Set audible confirmation for remote control operation and keyboard operation 1 means on and 0 means closed the default is on Example set panel without sound when remote control number 01 is sending signal Method one Pressing to entering the setup and then press 55010 press Syntax then press to exit setup 55 _ Remote Example set panel without sound when use keyboard to control number arm disarm 000 120 0 1 Method one Pressing to entering the setup and then press 55 0 press then press to exit setup Method two After calling and connected to the panel from remote press 55 xxOH Method three Send SMS messages1234 55 xx0 Set date and time Set the system date and time settings Example it is now 1 of July of 2012 9 00 00 am Syntax 56 Method one 4 digits year Press to enter the configuration mode press the 01 12 The Month 01 31 Day p0 23 Hour 00 59 Minute 00 59 Second 5620120701090000 press then press to exit Setup Method two After calling and connected to the panel from remote press 56201207010900008 Method three Send SMS message 12345620120701090000 Scheduled disarm time setting arm and Syntax 57 Group number 01 04 AAAA Scheduled
20. he disarm button of remote control Syntax to shut it off Suggestion you d better to put the remote 57 Group control above your bed number 05 06 J Example set the first alarm time start 7 30am and end at AAAA start 7 32am weeks 12345 are effective BBBB end J Method one Press enter the configuration mode and then Number of week J Press 57050730073212345 Example set the second alarm time start 13 40pm and end at 13 45pm weeks 12345 are effective Method one Press enter the configuration mode and then press57061340134512345 press and then to exit Setup Method two After calling and connected to the panel from remote press 57050730073212345 And 57061340134512345 Method three Send SMS message 123457050730073212345 and 123457061340134512345 Delete the clock To delete the 2groups scheduled alarm time time Example delete the first group scheduled alarm time Syntax 57 Group number 05 06 0 Method one Press enter the configuration mode and then presso7050 Method two After calling and connected to the panel from remote pressd7050 Method three Send SMS messagel123457050 Scheduled disarm zones settings arm and Syntax 58 Group number 01 04 K 000 120 zone begin the area J 000 120 Defense zone ends area code Defense code Used to set when the four group of zone to be controlled by
21. m means press the Scheduled arm disarm button Urg LED 97 alarm 97zone alarm means tamper KEYLOCK LED alarm Recording LED SIM card indicator GSM Signal indicator Intercom indicator Four digital LED 3 Installation of Panel 3 1 Alarm Panel Initial Setup Load the SIM Card connect telephone line fix the GSM Antenna connect the power and other cables if any then power up alarm panel The alarm panel voice prompt Welcome to use alarm system and start self test the GSM network LED shows SIM and GSM light on means GSM signals and SIM card are normal it takes about 10 seconds or so for searching Upon everything working properly the battery switch should be at the ON position for continuous charging 3 2 Pre record Voice Message Alarm panel will play a pre recorded voice message after the alarm call when a pre set phone number upon alarm To record customized message e Press Key to enter the configuration mode e Then press 19 speak your message at the panel for recording e System will record 10 Seconds and then automatically exit or press any key to end whenever your message end e Press then exit setup status 3 3 Add Remote Control Press key to enter the configuration mode e Syntax 07 000 120 to configure remote control Example 07 then press 001 to configure the Ist remote control then press any key of the remote control to send a signal to the alarm panel pan
22. mber 13888889999 1 phone number for SMS message is 13888889999 essage means alarm the Query the assignment of remote control to specific defense zone Example Send 123454001 to the alarm panel the alarm panel replies 001 remote control zone range 000 120 Keyboard zone range 000 120 means 001 remote control is assigned to control zone 000 120 and keyboard is assigned to control zone 000 120 Query the system time Example Send 1234564 to the alarm panel the alarm panel replies System clock 2012 07 01 12 00 Means the system is now 1 of July of 2012 12 00 00 am For query the four group of the scheduled arm and disarm scheduled arm disarm 57 01 04 Query the type and siren setting of wireless defense zone 60 000 120 Query the settings of wired defense areas 61 051 052 Query phone number assignment to zone 63 000 120 SMS certain Customize the message for zone 80 000 120 message SMS Query the customized SMS message content 81 000 120 Example 123457014 to the alarm panel the alarm panel replies Group 1 timing Arm time 12 00 Disarm time 13 00 Arm Disarm week 12345 Zone range 000 120 Means the first group scheduled time to arm at 12 00 am and disarm at 13 00 pm this is valid for Monday Tuesday control Wednesday Thursday and Friday of each week
23. n 0 is off default is on Example users need to disable the audible confirmation Method one then press 110 then press To exit Setup Method two After calling and connected to the panel from remote press 110 Method three Send SMS message 12341104 Enable or disable the SMS Messaging Syntax 12 0 1 l is on and 0 is off Default is on Example the user will need to turn off the text messaging feature Method one Press Then press 120 press then press exit setup status Method two After calling and connected to the panel from remote press120 Method three Send SMS message 12341204 Siren volume Valid value is from 00 to 99 as largest system default is adjustment the largest Syntax Example users need to set volume to 50 14 00 99 Method one press and then press1450 press and to Exit Setup Method two After calling and connected to the panel from remote press1450 Method three Send SMS message12341450 Forced disarm from Upon alarming enforced to use only the panel keyboard to panel keyboard disarm remote control is not allowed for extra security Syntax 15 0 1 the system default is off Example user needs to enforce to use keyboard Method one and thenl5l1 press and to Exit Setup l is on and 0 is off Method two After calling and connected to the panel from remote pressl51
24. n select the included period of time and different defense zone eliminating of need of the manual procedure realizing the beauty of automatic controls Support configuration via keyboard phone handset or SMS messages to System 6 group voice alarm phone number for alert calling 3 group phone number for help senior 6 group for SMS messaging numbers saved inside EEPROM without lost upon power failure Different zones can dial a pre set telephone number Support ISD automatic voice mailbox for playback message upon alert Maximum length of voice message is 10 seconds Telephone phone long distance telephone control for arming disarming monitoring remote announcement 1 Set of normally open signal outputs relay linkage output home appliances remote control can be realized Wireless intelligent study coding compatible with PT2262 normal encoding and a 1527 encoding convenient and flexible for adding or reducing accessories Maximum support 150 remote control and 150 sensors Unique black box features you can display most recent 72 disarmed records and 102 recent alarm recording Accurately shows the alarm time and control code Built in Ni Hi rechargeable battery and automatically switchable upon power failure and notification will be sent via SMS Panel integrated with quad band GSM GPRS industrial graded module stable and reliable 2 Anatomy of the120 wireless Zones Intelligent GSM alarm system
25. ne number for certain zone alarm panel will respond to all other SMS commands by replying confirmation of setting by SMS 4 2 Commands of System Enquiries Q Press Q button on panel to enter the query mode alarm panel status LED is blinking Then put in commands as detailed in table below when finished Press and then press to exit the query mode Note In case keyboard password protection is enabled please enter tne password to unlock before other commands Query for voice alarm phone number To query the alarm panel currently saved to the first set to the Nineth group voice alarm phone number Syntax 3 1 9 Press alarm panel query key of your keyboard and then press 31 the alarm panel LED show 13812345678 means alarm panel s first set of alarm numbers are 13812345678 Query SMS message alarm phone number To query the alarm panel currently saved to the first set to the sixth group phone number on the alarm panel for SMS Syntax 4 1 6 messages Press alarm panel query key of your keyboard and then press 41 the alarm panel LED show 13812345678 means the first set of SMS message is 13812345678 Query password Used to query the current password of the alarm panel Press alarm panel query key of your keyboard and then press 50 Syntax 50 L the alarm panel LED show 1234 alarm panel your current password is 1234 Press to clear the screen press
26. ng any instruction within 20 seconds 1 key arming 2 key disarming 3 key monitoring open 4 key monitoring closed 5 key turn on announcement 6 key turn off announcement 7 key siren ringing 8 key stop siren sound 9 key turn on relay 0 key turn off relay key hang up system will not dial the next number on list Remark If not hang up using key or disarm using 2 key the system will retry to call the next phone numbers on list until one connected Panel will not ask for password when dialing out upon alarming Monitoring time is 20s press 3 to monitor again press 3 5 to enter the remote intercom status and can press 5 to continue after 20s 5 2 Remote Dialing In Operation Remote control operations can be done via any phone You can just dial into the alarm panel and user will be asked for password upon connected and alarm will automatically hang up call within receiving any instruction within 20 seconds or password is incorrect original password 1234 1 key arming 2 key disarming 3 key monitoring open 4 key monitoring closed key turn off announcement 5 key turn on announcement 6 key siren ringing 3 5 7 8 key stop siren sound 9 key turn on relay 0 key turn off relay key hang up key Enter the system remote configuration mode Without receiving no instruction the panel will automatically hang up after 20 sec
27. od three Send SMS message 1234200 Remark If enable the alarm linkage function when alarming the relay absorption would change the circuit condition between NO and COM The time of relay actuation When disable the alarm linkage function the relay of the panel can remote control is the same with siren sound time the home appliance After calling and connected to the panel from remote input the password press 9 the relay on 0 OFF Or send SMS 12343 0N 123444 Means OFF Restore factory setting System restore factory setting Method one and then press 9898 Syntax 9898 Method two After calling and connected to the panel from remote press 9898 Method three Send SMS message 12349898 Remark This feature will restore all settings to factory default apart from the configuration of sensors and remote control Total System Reset Syntax Press and hold the ARM button on the keyboard and power on Disconnect power to the alarm panel turned off the battery switch alarm panel then press and hold the alarm panel of ARM button while power on The system will respond with short beep slowly for 5 seconds then can release ARM button The system is now totally reset All configuration has been cleared all sensors and remote controlled are deleted and password is restored to original 1234 Note Other than the SMS commands for assigning specific pho
28. onds 6 Types of Alarm Zone 6 1 Definitions of ZonesThe alarm supports 120 distinguishable defense zones and they can be 21 classified into one of the 8 Zone Types with their respective characteristics Type Zone Type Interpretation ID 1 NORMAL Defense Zone the Panel only works on the arming status When disarming there is no response 2 STAY Defense zone can be shut off solely through the remote control AT HOME Defense keyboard to avoid the Infrared Detectors and other zone in room detectors from misinformation when master is resting at home 3 INTELLIGENT Defense if the detector in the Defense zone is triggered only zone once it will not immediately alarm But if being triggered once again within 30 seconds after the first triggering it will alarm immediately 4 EMERGENCY Defense no matter on arming or disarming status if detector zone is triggered it will alert Usually used in connecting with Smoke Detectors Gas Detectors and emergency button etc 5 CLOSED Defense zone no matter arming or disarming status detectors will not alert even being triggered 6 CHIME Zone No matter in what status when sensor with this zone is triggered a welcome door bell will be ring as notification 7 WELCOME Zone Only work on the arming status when sensor with this zone is triggered a welcome voice message will be played 8 HELP SENIOR Defense This type of zone is for elderly safety no
29. ress enters the configuration mode press 610511 Then press To exit Setup Method two After calling and connected to the panel from remote press 610511 Method three Send SMS message 1234610511 Remark On the back pane of the alarm panel 051 labelled Z51 status when Z51 and GND to be short circuit condition the set 51 zone to NO alarm in the arm alarm system would be alarming 052 labelled Z52 set 51 zone to NC alarm in the arm status when Z51 and GND to be open circuit condition the alarm system would be alarming Usually Suitable for connect the alarm port of the wired accessories Set Remote Operation on or off Syntax 62 0 1 This enable or disable the remote operation of alarm panel using telephone System default is on Example turn off the remote setting function Method one Press enter the configuration mode and press 620 then press To exit Setup Method two After calling and connected to the panel from remote press 620 Method three Send SMS message1234620 Assign specific phone number to certain zone Syntax L 63 000 120 zone begin the area code 000 120 Defense zone ends area Defense code Phone alarm number 123456 J System default is all 000 120 defense zone will make call from the first to sixth group phone number upon alarming Example user needs 00 10 to call the first second third
30. set of numbers Method one Press enter the configuration mode and press 63000010123 Example users need to 11 20 zone alarm the fourth the fifth and the sixth group number Method one Press enter the configuration mode and press 63011020456 Example User want zone 21 call only the 5th group number Method one Press enter the configuration mode and press 630210215 Method two After calling and connected to the panel from remote press 630000101234 and press 630110204564 press 63021021 5 Method three Send SMS message 123463011020456 And 1234630210215 123463000010123 and Power mode ON OFF Save Syntax 84 0 1 Used to control the energy saving mode on or off 0 means off 1 means on ON means when alarm host in standby state it would be auto off the LED display after lminute enter the power saving mode OFF means when alarm host in standby state the LED display would stay on with time display Example users want to close the time display Method one Press enter the configuration mode and press 840 then press To exit Setup Method two After calling and connected to the panel from remote press 840 Method three Send SMS message 12348404 audible from Set confirmation panel to on or off Syntax 11 0 1 Alarm panel will produce audible confirmation beep upon receipt of signal from remote control or keyboard 1 is o
31. sion to all the wireless sensors and accessories Keep the panel well away from large metal objects or household appliances with high frequency interference and avoid barriers such as concrete walls with metal frame inside and fire doors 2 2 2 SIM Card installation SIM card installation is simple Firstly remove the cover of SIM card slot at the back of the alarm panel and then place the card according to direction indicated Make sure the cover of SIM card slot is fixed suitably SIM card installation yy mY in ee w Ji km Z 2 35 Summary ot indicators Function Indications Description Built in speaker short beep once Confirming key signal received beep beep two short tones Exit configuration or learnt succeed beep beep beep three short Error indication tones Voice prompt The prompt voice of the function and status Power LED Light up Meaning the panel external power is normal OFF External AC outage internal battery power supply low voltage LED Light up The backup battery is low voltage Arm LED Light up and LED show BF for Arm 1S Flashing Delay arm off Disarm Stay arm LED Light up and LED show LB for Stay arm 1S off In the standby status the host enters into Power saving mode and display off after l1minutes Alarm LED Light Show the current time or the alarm state Clock LED 98 alarm 98 zone alar
32. ss alarm panel query key of your keyboard and then press 5501 the alarm panel LED show ON means remote control 1 is set to sound upon receipt of command Query the date of the alarm system Syntax 56 For query the date and time Press alarm panel query key of your keyboard and then press 56 the alarm panel LED show 2012 0601 1830 5 means now is 18 30pm 1 June 2012 Friday the scheduled time for arm and disarm Query Syntax 57 01 06 Used to query first to fourth set of scheduled time for arm and disarm Press alarm panel query key of your keyboard and then press 5701 to query the first of scheduled arm and disarm the 22 00 07 00 and 12345 means schedule set as From Monday to Friday 22 00 pm arm and 07 00 am disarm alarm panel LED show Mon Tue Query the zone number with scheduled arm and For query the first to the fourth group scheduled arm and disarm Press alarm panel query key of your keyboard and then press 5801 for zones with the first group of zone the alarm panel LCD show 000 120 group means 000 120 zone are with 1 number disarm Syntax 58 01 04 Query type wireless defense zone Syntax 60 000 120 For query the zone types of 000 120 Press alarm panel query key of your keyboard and then press 6000014 The alarm panel LED show 1 means NORMAL 2 means STAY ARM 3 means INTEL
33. t of remote control to defense zone 54 000 120 Query the system time 56 Query the status of Query the alarm panel status included arm disarm relay status status of integrated alarm status of SMS messaging status delay alarming of remote operation password setting delay arm setting length of time of siren sounding volume of siren keyboard locking status audible confirmation Example Send SMS message 123411 to the alarm panel the alarm panel replies with a list of related setting Disarming diarm status Relay out off relay off Green power saving mode Alarm out on alarm linkage on Send SMS on SMS messaging on Remote set on remote operation on Password 1234 the password is 1234 Alarm delay 00s delay alarming 0 second Arm delay 00s delay arm 0 second Siren on 1 min siren sounding time 1 minute Siren VOL 99 volume of siren 99 Crack off turn off the unction forced disarm from keyboard Disturb off gt Key lock off keyboard not lock turn off Interference Alert Voice on gt voice on Return a list of 1 to 9 phone number group for voice alarm Example Send 12343001 to the alarm panel the ala replies Group 1 phone number 13712345678 means the first number is 13712345678 m panel voice alarm phone Query first to sixth group of phone number for SMS Example Send 12344001 tothe alarm panel the alarm panel replies Group 1 SMS nu

Download Pdf Manuals

image

Related Search

Related Contents

manuel-carlina-2015 - Néomouv - vélo à assistance électrique  Compaq 6500 Family Laptop User Manual  MANUAL DE INSTRUÇÕES  FGA311 Panametrics In Situ Flue Gas Oxygen Analyzer User`s Manual  "取扱説明書"  the Technical Manual  Préconisations relatives au tri et à la conservation des archives  User Manual MEG · DRY · MOA · REG 2 · REG 3  Sencor STM 3013OR mixer  703607-WB Rev L - Control Unit Users Manual.indd  