Contents
1. a Logon in Controller Program Mode b Delete Card Procedures gt DEI by Serial No key in serial No Del card A A Del All cards select Yes Operation Proceducer Function Key Press EN to 1 y Page Down Function Menu enter A Page Up Down Enter Key 5 Number Key Press En to Eni r Escape to Previous Menu Shift Key A Page Up Figure 4 2 2 Delete Card 15 4 2 3 Modify Card Data a Logon in Controller Program Mode b Modify Card Procedure A Vv Card status Enable Disable App set App 01 16 Edit Card data Key in No Pin setting Card Pin 0 A Enable Disable Defne Pin card APB setting APB check Operation Proceducer Function Key Press EN to AA Page Down Function Menu enter A y Page Up Down Enter Key M Number Key Press En to Enter Escape to Previous Menu Shift Key A Page Up Figure 4 2 3 Modify Card Data 16
2. 2 Wiring Connection Type Of Connection a Controller to Personal Computer b Controller to Card Reader c Controller to Extension Module d Input Output Contact Build in Controller Detail Connection as follow 2 1 Controller To PC Controller link to PC by RS485 Communication module Maximum distance from PC to Controller is 1 SYLINK Connector PIN 3 Green Color PIN 2 Yellow Color PIN 1 Black Color SY210NT Main PCB KM A single Controller M4 Connector PIN 1 4A Blue Color PIN 2 4A Purple Color PIN 5 GND Black Color PIN 3 4A PIN 2 4A PIN 1 GND Figure 2 1 Connection from SY210NT to PC Caution RS485 Communication Wire must be Twisted Screen Cable grade AWG18 24 depend on distance Controller to Card Reader 2 2 Controller link to Card Reader by RS485 Communication mode max distance from Controller to Card Reader is 1 KM A single controller can connect up to max 8 Readers Reader Wire Green Color 4R Yellow Color 4R Red Color 5 12VDC Controller M4 Connector PIN 3 4R Grey Color PIN 4 4R White Color Controller to Other Module MDDIDO Module DIDO Module consist of a Power Supply DC 5 12V b RS485 Line Link to Controller 4R 4R c DO Ouput 4DO 8DO 16DO d DI Input 4DI 8DI 16DI DO
3. 42 4 Show Card Number Card Code Numbers Fix Internal Number Card Serial Numbers Depend on programming Sequence a Logon in Controller Mode b Show Card Number Procedures Figure 4 2 4 Show Card Number 17 4 3 Set DI Parameter 43 1 DI Holiday Time Zone Setting Logon in Controller Program Mode a b Go to Time Zone Menu Select Set DI Set Programming Produces Key in TZ No Before Holiday Holiday After Holiday Page Down Number Key Shift Key Key in Holiday No Set DI A h Holiday TZ Function Key Function Menu Enter Key Escape to Previous Menu A Page Up Figure 4 3 1 Set DI Holiday Time Zone 18 Key in DI No 1 8 Operation Proceducer Press EN to enter A Page Up Down Press En to Enter Key in TZ Page Down Number Key Shift Key 43 2 Set DI Week Time Zone a Logon in Controller Program Mode b Go to Time Zone Menu Select Set DI Set c Programming Produces Key Week No 1 7 Set DI A vy Week TZ Function Key Function Menu Enter Key Escape to Previous Menu A Page Up Figure 4 3 2 S
4. Figure 4 5 1 Anti Passback Setting 44 3 Set APB for Individual Card a Program only for those cards required APB b Logon in Controller Program Mode c Program Procedures v Edit Card M A v Set APB Yes No Figure 4 5 2 Set Card APB 24 4 5 Set Door Lock Release Time a SY200NT controller will send a signal output to release the lock Relay 1 to 4 if valid card is read The setting is to determine how long you want the lock to remain open Logon in Controller Program Mode c Program Procedures Figure 4 6 Set Door Lock Release Time 4 6 Set Timer TimeZone Holiday TimeZone 4 6 1 Set Timer a A Total of 30 Timers may be programmed The 25 4 6 2 Set TimeZone A Total of 60 TimeZone may be programmed Each with 3 sets of timers TimeZone is important and used in access control and DIDO programming etc Logon in Controller Program Mode Programming Procedures aos Figure 4 7 2 Set TimeZone Timer setting Timer No Start Time End Time A h 01 30 Set Holiday TimeZone a Holiday access control include Holiday Eve Holiday and day after Holiday b To define Holiday Access Control must go to TimeZone Menu sele
5. Dry Contact Output DI Dry Contact Input Stalus indicate LED LED 1 4 DO Output LED 5 8 DI Input LED 9 RS485 Blinking Figure 2 3 1 DI4Do4 Module Connection 2 3 Please contact factory for other DIDO Module wiring connection 2 3 2 Printer Module SY200NT Controller can connect to the following printers directly or reports printing via printer module 1 Do Metrics Printers 2 Inkjet Printers 3 Laser Printers seine Figure 2 3 2 Connection of Printer Module 2 3 3 AI Module Please contact factory for AI Module Connection 3 System Setup 3 1 Power up procedures 3 1 1 Before power up ensure all wiring connection is correct 3 1 2 When the power is turned on the controller will automatically initialize and the LED change from Green to Red with a short Beep sound 3 1 3 Ifthe controller is ready LCD will show Date Time 3 2 System Setting 3 2 1 Go to program mode Follow Figure 3 2 1 to go to program mode Figure 3 2 1 How to Go to Program Mode You are in program mode now 3 2 2 Set Card reader ID a Goto System System Process Change Reader ID b Key in Reader Serial Number and Reader ID c Repeat step b to set all card reader ID Figure 3 2 2 Set Reader ID 3 2 3 Set Controller ID Controller ID Default Setting 01 To set other controllers ID follow the procedures below Figure 3 2 3 Set Controll
6. When the controller is In Check OK Valid Card it will active the output relay where the card is read Following is a example of flow control using DI Point for exit button No Event IDEvent ChanelE Action IDAction ChanelAction Method Time vent 37 DIOn 9 1 SY200 DO Open 1 3 3 As above setting table Event DI On Ask controller active when DI Point is On Event ID 9 the DI Point come from SY200NT internal DI Chanel Event 1 DI Point is the first one Action SY200 DO setting SY200 DO 15 for action point IDAction Open set action is open ChanelAction 1 output is come from DOI Method 3 active time is in second Time 3 output active 3 seconds Program Procedures for above 36 37 4 10 Flowchart 38 Flowchart continue 39 4 11 Typical Wiring Connection 5 Technical Information 5 1 SY210NT Controller Specification SY210NT Controller Specification Items Spec SY210NT2 SY210NT4 Number of Cards 9 999 9 999 Number of Readers 4 2In 2Out 8 8In 8Out Door Control 4 4 Reader Technologies SYR
7. OY SY210NT Serial Controller Operation Manual Version 2 3 2005 by SYRIS Technology Corp User Manual Content Introduction 1 1 SYNT Serial Product 12 System Configuration Wiring Connection 2 1 Controller to PC 22 Controller to Card Reader 29 Controller to Other Module System Setup 3 1 Power Up Procedures 3 2 System Setting 33 PCB Layout of Typical SY210NT Controller Programming 41 Set Controller Date Time 42 Card Process 43 Set DI Parameter 44 DO Parameter Setting 4 5 Anti PassBack Setting 4 6 Set Door Lock Release Time 4 7 Set Timer TimeZone Holiday TimeZone 4 8 Set Application Set APPSET 4 9 Set Flow Process 4 10 Flow Chart 4 11 Typical Wiring Connection Technical Information 5 1 SY210NT Controller Specification 5 2 SYWIN95A Access Control Software 5 3 SYRIS Proximity Reader 5 4 Proximity Card 5 5 Power Consumption Item 1 Introduction 1 1 SY210NT Series Product SY210NT2 NT4 Card Access Controller SYRDS1 L5 Card Reader MDDIDO Input Output Module Printer Interface Module Proximity Card Other Application Module OD 1 2 System Configuration Figure 1 1 System Configuration
8. 4 7 2 Set Weekly TimeZone a To set Daily TimeZone and within a week Logon in Controller Program Mode C Programming Produces Figure 4 8 2 Set Weekly TimeZone Set APPSet No Set Holiday TZ Set Holiday No Key in TZ for Set Holiday Exit 16 A h Holiday Eve Control Holiday 0 Yes 1 Nol day After Holiday 28 4 7 3 Set Out Flag a The function is used to set the Exit Control for individual door b Logon in Controller Program Mode c Programming Procedures Figure 4 8 3 Set Out Flag 4 7 4 Set Door Fag a The function may be used to set the access level b Logon in Controller Program Mode c Programming Procedures Figure 4 8 4 Set Door Flag 29 4 7 5 Set Security PIN Code The function may be used to set Card PIN Common PIN Logon in Controller Program Mode Programming Procedures Figure 4 8 5 Set Security PIN Code Set Holiday TZ Set Holiday No Key in TZ for Set Holiday Exit Holiday Eve Control Holiday 0 0 1 Yes day After Holiday Set APPSet No 1 16 4 7 6 Set Personal PIN Code The function may be used to set Card PIN Personal PIN Logon in Controller Program Mode Programming Procedu
9. SY200 Ok LED Beep SY200 Error LED Bell SY200 Error LED Bell SY200 Error LED Bell SY200 Error LED Bell SY200 Error LED Bell SY200 Error LED Bell SY200 Active LED Action Check Card LED Sound Show Data Add InOut LED Sound Show Data Add InOut LED Sound Show Data Add InOut LED Sound Show Data Add InOut LED Sound Show Data Add InOut LED Sound Show Data Add InOut LED Sound Show Data Add InOut LED Sound Show Data Add InOut LED Default Flow Control Setting Chanel Event IDEvent Module Module Module Module Module Module Module Module Module Module Module Module Module Module Module Module Module Module Module Module Module Module Module Module Module Module Module Module Module Module Module Module Module Module AI All All All All All All All All All All All All All All All All All All All All All All All All All All All All All All All All All Event Card Sense In Check Ok In Check Ok In Check Ok In Check Ok Out Check Ok Out Check Ok Out Check Ok Out Check Ok Invalid Card Invalid Card Invalid Card Invalid Card Disable Card Disable Card Disable Card Disable Card Invalid TimeZone Invalid TimeZone Invalid TimeZone Invalid TimeZone Invalid Door Invalid Door
10. DO Set c Programming Produces Key in Week No 1 7 Set DO A h Week TZ Function Key Function Menu Enter Key Escape to Previous Menu A Page Up Figure 4 4 2 Set DO Week Time Zone 22 Key in DO No 01 16 Operation Proceducer Press EN to enter A vy Page Up Down Press En to Enter Page Down Number Key Shift Key 4 4 3 Set DO Action Status a Logon in Controller Program Mode b Go to Time Zone Menu Select Set DO Set c Programming Produces Action Typr 0 Not use 1 Always 2 by Min v Key in DO SetAction Type No 01 16 A v Operation Proceducer Function Key Function Menu enter v Page Up Down Enter Key Press En to Enter Escape to Previous Menu Page Up Figure 4 4 3 Set DO Action Status 23 gt Anti Passback Setting 44 2 Set APB for Individual Door a System Provide 3 Class APB Level b Programming Procedures 0 IGNORE AREA 1_2_3_4_ 1 LEVEL 1 A A h 2 LEVEL 2 3 LEVEL 3
11. IS RS485 format SYRIS RS485 format User P LN code 4 digital code 4 digital code Normally 4 Expandable to 64 Normally 4 Expandable to 64 RS485 2 Ports Baud rate 19 200 bauds 19 200 bauds Programmable time zone 60 time zone 60 time zone Group application set 16 16 Holidays 366 366 Controller ID 01 99 01 99 Expand modules SYRIS NT Serial Module SYRIS NT Serial Module Up to 3 level of local and or group anti passback Keypad input 16 key keypad 16 key keypad Keypad backlight Built in Built in LCD display 8 x 2 LCD with backlight 8 x 2 LCD with backlight Speaker output Maximun 0 2 W Maximun 0 2 W Indicator 5 LED 5 LED Operating temperature 2 Cto55 C 2 Cto55 C Storage temperature 25 010 85 C 25 010 85 C Power supply input DC 11V to 20V DC 11V to 20V Power consumption 1W to 10W 1W to 10W 107W x 150H x 27D Normally 4 Expandable to 64 Normally 2 Expandable to 64 RS485 2 Ports Up to 3 level of local and or group anti passback 107W x 150H x 27D SYW95A Access Control Software Control relay Output Communication ports Input Points Anti passback Dimensions mm Link up to 99 Controllers 396 doors 792 Readers 40 3 level of anti passback User define language 6000 card holders 5 3 SYRIS Proximity Reader SYRIS Proximity Reader Specification Water resistant high security high durability and low identifi
12. Invalid Door Invalid Door Invalid ReEntry Invalid ReEntry Invalid ReEntry Invalid ReEntry Invalid ReExit Invalid ReExit Invalid ReExit Invalid ReExit Card Sense RS 06 J DA u No 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 Flow Control Instruction Following is a example of flow control after it sense a card Chanel Action 34 IDAction Action Chanel Event IDEvent Event No Second 2 Second 2 Ask all module reader of controller to read card and ask controller to check card status When In Check OK reader ID 1 entry reader the OK LED of controller will changes to green Green Card Find No 35 Ok LED Beep SY200 Check Card LED Sound Show Data Add InOut All Module AI Module AI Module AI Module AI Module Card Sense In Check Ok In Check Ok In Check Ok In Check Ok N color and active for 2 seconds 3 When In Check OK controller will create a Beep sound 4 When In Check OK the controller LCD will show card serial number and it will active for 2 seconds 5 When in Check OK controller will add a record to InOut transaction data base ABI UN F
13. cation error rate Can be mounted directly on metal without affecting its reading performance SYRIS proximity reader is able to interface with all existing access control system by Wiegand formats lecti 9 9Tj TT12 1 Tf0 7519 0 TD Tj TT2 1 Tf1 5038 0 TI 41 42 Power Consumption DC12V Power consumption per unit 400ma 100ma 100ma 250ma Items Spec Controller Card reader Printer Module DIDO Module 5 5
14. ct APPSET to set Holiday TimeZone first A total of 8 Holiday TimeZone may be set d Programming procedures Figure 4 7 3 Set Holiday TimeZone z Timer setting Timer No Start Time End Time A 01 30 26 4 6 3 4 7 Set Application Set APPSET APPSET Setting List Edit Holiday TimeZone Edit Weekly TimeZone Set Out Flag Exit control Set Door Flag Door Access Control Set Security PIN Code Common PIN Set Personal PIN Code APP Group PIN monogs APP Set Flow Chart Set APPSet Data A Set AppSet No Set Holiday TZ Se Week TZ Set OutFlag Set DoorFlag Set Security Set Personal PIN Code PIN Figure 4 8 APP set Flow Chart 27 4 7 1 Set Holiday TimeZone a The Controller Provides 8 Group of Holiday TimeZone Date include Holiday Eve Holiday and day after Holiday b Logon in Controller Program Mode c Programming Procedures Figure 4 8 1 Set Holiday TimeZone Set APPSet No Set Holiday TZ Set Holiday No Key in TZ for Set Holiday Exit 1 16 A v Holiday Eve Control Holiday 0 No 1 Yes day After Holiday
15. er ID 3 2 4 Get Card Reader Link to Controller The linking of card reader to controller is not completed until the following step is done Figure 3 2 4 Module Plug amp Play Auto detect AV AV AV AV 3 2 5 Store Cards I Controller Upon completion of System Setting it is important to store all user cards in the controller The produces is shown as below Figure 3 2 5 Store Cards in Controller AV AY Flash a card AV AV continus flashing cards to automatically add 3 2 6 Confirmation for Systems Set Up a The systems set up is completed after going through above steps 3 2 1 to 3 2 5 b Press CLR repeatly until the LCD of controller show Date amp Time c To confirm that the systems is properly set up flash any of the cards previously stored in the controller to mak sure the OK LED lighted and the LCD show card serial number 10 3 3 PCB Layout of typical 3 3 1 The PCB layout of SY210NT controller Door 2 Output Relay 2 Door 1 Output Relay 1 Power Door 4 Output Relay 4 Door 3 Output Relay 3 pCOV k ID meee lt DC 12V Relay Output Network Connect 5 Output 4R WHT or Yellow Pin3 4A 4R GRN RS485 Pin2 4A Connector Pinl GND To other Reader or Module To other Controller Figure 3 3 1 The PCB Layout of SY210NT Controller 11 3 3 2 The following setting 1
16. et DI Week Time Zone 19 Key in DI No 1 8 Operation Proceducer Press EN to enter A Page Up Down Press En to Enter 4 3 3 Set DI Action Status a Logon in Controller Program Mode b Go to Time Zone Menu Select Set DI Set c Programming Produces Value Enable Disable 1 DI ON Action 2 DI OFF Action 3 DI Float Action 4 DI Change Action vy Page Down Set DI Input A Function Key Function Menu Enter Key Number Key Escape to Previous Menu Shift Key Page Up Figure 4 3 3 Set DI Action Status 20 Key in DI No 1 8 Operation Proceducer Press EN to enter A h Page Up Down Press En to Enter 4 4 DO Parameter Setting 44 1 Set DO Holiday Time Zone a Logon in Controller Program Mode b Go to Time Zone Menu Select Set DO Set c Programming Produces Figure 4 4 1 Set DO Holiday Time Zone 21 Key in TZ No Page Down Number Key Shift Key 442 Set DO Week Time Zone a Logon in Controller Program Mode b Go to Time Zone Menu Select Set
17. le No None 1 20 59 SY200NT 60 ALL Action Table Item Event Description Function ID 0 9 Channel 0 60 Method 0 4 1 SY200NT LED Code LED Color 1 always Time 1 OkLED 1 Dark Blacklight Off 2 100ms 1 999 2 Error Led 2 Red Blacklight On 3 sec 3 Set up LED 3 Green 4 min 4 Active LED 4 Orange 5 BlackLight LED 2 Set Sound Sound Code 1 always Time 1 Beep sound 2 100ms 1 999 2 Do Sound 3 sec 4 min 3 Set Alarm Alarm Code 1 always Time Sound 1 Steal 2 100ms 1 999 2 Emergency 3 sec 3 Fire Alarm 4 min 4 Gas 5 Error 6 Duress 4 Set DO Action DO Point 1 4 1 always Time 32 1 999 Time 1 999 100ms sec min always 100ms sec min D KIB Wb 33 Door 1 4 DO Point 1 16 1 Open 2 Close 3 Change DIDO Module ID 1 8 System Internal DO Set DIDO Module DO Point On Time Time Method Second Second Second Second Second Second Second Second Second Second Second Second Second Second Second Second Second Method Chanel Action Green Card Find No Green Card Find No Red Invalid Card Red Disable Card Red Invalid TimeZo ne Red 2 Invalid Door 5 Red 2 Invalid ReEntry 8 Red Invalid ReExit Red IDAction Ok LED Beep
18. res Figure 4 8 6 Set Personal PIN Code Set Holiday TZ Set Holiday No Key in TZ for Set Holiday Exit A Holiday Eve Control Holiday 0 0 5 day After Holiday 30 Set APPSet No 1 16 Set Flow Process SY200NT Controller Provide A Total of 26 Events for detection A Total of 11 Actions for Execute SY200NT will work depending on following sequence Source Detecting Events Target Action Mode Action Mode Event Table Ite Description ID 0 9 Channel 0 60 31 9 SY200NT 15 DI Float 1 8 1 16 DI Point 0 99 MDDIDO Seconds 9 SY200NT 16 DI Change Status 1 8 1 16 DI Point None MDDIDO 9 SY200NT 17 DI Set On 1 4 DI Point 1 4 TimeZone None Number 18 DI Set Off 1 4 DI Point 1 4 TimeZone None Number 19 DI Set Float 1 4 DI Point 1 4 TimeZone None Number 20 DI Set Change 1 4 DI Point 1 4 TimeZone None Number 21 DO Set On None 1 60 TimeZone None Number 22 DO Set Off None 1 60 TimeZone None Number 23 Time Out None 1 60 TimeZone 0 99 Number Seconds 24 Forced None 1 60 TimeZone 0 99 Number Seconds 25 Duress None 1 60 TimeZone None Number 26 HardWare Error None Modu
19. s fixed by the systems Card Reader ID Controller Output Reader ID I Door 1 Entry or 5 Door 1 Relay 1 Exit Reader ID 2 Door 2 Entry or 6 Door 2 Relay 2 Exit Reader ID 3 Door 3 Entry or 7 Door 3 Relay 3 Exit Reader ID 4 Door 4 Entry or 8 Door 4 Relay 4 Exit Reader ID 1 is for Door 1 Entry Reader likewise ID 2 is for Door 2 Entry Reader and similar to ID 3 and ID 4 Reader ID 5 6 7 and 8 are for Door 1 2 3 and 4 Exit Reader 12 Programming Set Controller Date Time Set Time Figure 4 1 1 Set Time Set Date Figure 4 1 2 Set Data 13 4 2 Card Process 42 1 Store Card to Controller a Logon in Controller Program Mode b Store Card Procedures Flash Card in sequence Flash Card Add Car A v A v Add Card by Key in serial Fl sh a card Serial No No Operation Proceducer Function Key v Page Down Press EIN Function Menu enter A Page Up Down Enter Key Number Key Press En to Ente Escape to Previous Menu Shift Key A Page Up Figure 4 2 1 Store Card 14 42 2 Delete card from Controller