Home
Model 1827 - AMTEST-PL
Contents
1. NOTE Measurement speed is determined by a number of factors These are calculated measurement times based on instrument mea surement mode and test frequency There are three user selectable measurement speeds Trigger Internal and External Triggering External Triggering is achieved through the Front Panel or through rear mounted user interfaces Measurement Terminals 5 Terminal Kelvin Configuration BNC Connectors for Kelvin and a Guard Binding Post Zero Offset Open gt 1kQ or Short Circuit lt 1kQ Null Comparator HI GO LO Dual Comparator Functions for A amp B Displays External Buzzer Set for PASS FAIL of Comparator Functions Stored Settings 99 Stored instrument Settings May be stored or recalled through the front panel or remote interface Front Panel Key Lock User is able to lock the front panel to prevent accidental bumping of the front panel keys User Interfaces CONTROL I O Connector Standard RS 232C Standard GPIB IEEE 488 Optional PN 3501 BCD Interface Optional PN 3502 Safety Conforms with IEC 61010 1 CE Marked Operating Environment Storage Environment 32 104 F 0 40 C lt 80 RH Non Condensing Double the measurement errors for conditions outside of this range 14 131 F 10 55 C lt 80 RH Non Condensing Power Requirements User Selectable 100 120 220 amp 240 VAC 50 60 Hz Consumption 20V
2. 9 DOGO sud paci dh erIAPEEE BS Sras 9 DOO 43652 345 c5 wd dette nb EAS 9 DIZD 43 5522 99 9 ue as DOE dE PE ee 9 8000 RF Mount Transport Case A 27 8012 6 Input Switch Box T C Type K I 9 8022 6 Input Switch Box T C Type J I 9 8052 6 Input Switch Box T C Type T I 9 8204 Rubber Boot for 840 amp 850 and 819 amp 820 Series D 2 8660 Tilt Stand Belt Clip Probe Holder for 865 866 869 amp 874 l 8 8662 Temperature Probe Thermistor Encapsulated l 6 8663 Temperature Probe Thermistor General Purpose Immersion l 6 8665 Temperature Probe Thermistor Surface l 6 8666 Temperature Probe Thermistor Air Gas l 6 8668 Soft Carrying Case for 819 820 821 865 866 868 869 871A 872A amp 874 l 8 8693 Temperature Probe 100 ohm RTD General Purpose Immersion l 7 8695 Temperature Probe 100 ohm RTD Surface l 7 Contact TEGAM Inc at 440 466 6100 for information INDEX BY MODEL NUMBER 8696 Temperature Probe 100 ohm RTD Air Gas 8712 Temperature Probe T C Type K Wire 3ft 8712 6 Temperature Probe T C Type K Wire 6 ft 8713 Temperature Probe T C Type K General Purpose 8714A Temperature Probe T C Type K Penetration with Coiled Cable aonana anaana annaa eee 8715 Temperature Probe T C
3. F1119 RF Power Standard 100KHz 4 2GHZ F1119H RF Power Standard 100KHz 4 2GHz High Power F1119C F1119 Power Standard Mounted in an Enclosure F1125 RF Power Standard 100 KHz 4 2 GHz een A 7 F1130 RF Power Standard 100kHz 18GHz A 9 F1135 RF Power Standard 10MHz 26 5GHz A 11 FG501A 2 MHz Function Generator FG502 11 MHz Function Generator FG503 3 MHz Function Generator FG5010 Programmable 20 MHz Function Generator KC 2600 Kelvin Klips for Model 2600 Series LCR Meters Kit 1 Calibrator Accessory K K J T amp T Cs for 840A amp 845 D 2 Kit 5 Calibrator Accessory Kit Multi T Cs RTD Ohms amp Thermistor for 850 amp 855 D 2 KK100 Kelvin Klip Replacement Kit C 23 KK110 Kelvin Klip Cable 3 Feet LONG JOR 242 cae wan eGR week Rees C 23 M1000 o he 2655035589 22 ee ae MIUUT obi Re tapes sees ease MIUDS pce esas ire bse ee dob a M 1011X as eoo cee tae needed ea aes M 1012X 9 M1110 RF Power Standard 0 01 18GHz N Male Connector A 5 M1111 RF Power Standard 100KHz 100MHz M1118 RF Power Standard 0 05 26 5GHZ eene M1120 RF Power Standard 100KHz 4 2GHz A 7 M1130 RF Power Standard 100kHZ 18GHz A 9 M1135 RF Power Standar
4. Remote Programmability Compatible with IEEE 488 STD 1987 Connectors RF Inputs PLANAR CROWN female Type N 10 MHz External Input female BNC 10 MHz Output female BNC 30 MHz Output female Type N AUX Output female SMA Digital Interface 24 pin IEEE 488 Input Power Requirements 100 120 220 240 Vac 10 50 to 60 Hz Power Consumption 180 Watts EMI Designed to meet MIL STD 461 for radiated emission and susceptibility Design and Construction Designed to meet requirements of MIL STD 28800D TYPE III CLASS 5 STYLE E Environmental 0 to 50 C 432 to 122 F 40 to 75 C 40 to 167 F Operating Temperature Storage Temperature Humidity 05 Physical Dimensions Height 5 2 in 133 3 mm Width 16 8 in 426 7 mm Depth 24 4 in 619 8 mm Weight NET 65 Ibs 27 2 kg This data sheet was current when it was produced However products are constantly being updated and improved Because of this some differences may occur between the descriptions herein and the current product Prices and specifications may be changed without notice Certificate no 2018 01 BACK TO CONTENTS TEN TEGAM WAY GENEVA OHIO 44041 440 466 6100 FAX 440 466 6110 www tegam com e mail sales tegam com TEGAM YOUR GLOBAL SOURCE FOR TEST AND MEASUREMENT SOLUTIONS Model 8853 signal source 90 dB dynamic range with 0 04 dB 10 dB accuracy when used in 8850 system e
5. B 7 PA e E o e e E eee 240C Kelvin Ratio Bridge 72 4 p Pp TP 9 242D Resistance Measuring System TODDII accus eus mmm nn 242D SP3632 Resistance Measuring System 5ppm 242E 242D with 801C DC Generator Detector 250DE 229921 tresen tinahena SUI 228 ssc oe oe oe aue e add 252 LCR Meter 1KHz 252 SP2596 Bat Powered 253 LCR Meter 1KHz 253 SP2598 Bat Powered 254 LCR Meter 120Hz 202 ac cei aes pone ee Ad RE A mare d no 9 POT ss2aiossuoskd s edina d Reb rdeR 9 SUTA Ebor E CHO EE E 9 801B DC Generator Detector for Model 242 seen 801C DC Generator Detector for Model242 eene 819 Thermocouple Thermometer Single Input K J amp T 1 819 RB Model 819 with Rubber Boot 1 820 Thermocouple Thermometer Dual Input K amp J l 1 820 RB Model 820 with Rubber BOO l 1 821 Thermocouple Thermometer Dual Input K J amp T l 1 821 RB Model 821 with Rubber EDO ene Sheet bee ERES l 1 840A Calibrator Thermometer ce C Se K J amp T ossa su ree d D 1 845 Calibrator Thermometer co C amp ooF Multi T Cs D 1 847 Economical Calibrator oo C amp coF K J amp T acids Rewer etna as l 9 850 Calib
6. YOUR GLOBAL SOURCE FOR TEST AND MEASUREMENT SOLUTIONS Prices and specifications subject to change without notice BACK TO CONTENTS A 25 A 26 System IIA AUTOMATIC RF POWER SENSOR CALIBRATION verification and or calibration of the linearity of measurement devices such as power meters meter scales power meter mount combinations spectrum analyzers and receivers to achieve a 10 mW power level a signal source with an output of 100 mW is generally necessary Precision RF Power Meter With the addition of a Primary RF Power Transfer Standard e g Model M1110 and a Model 1806 Dual Type IV Power Meter System IA capability is expanded so that the working RF Power Transfer Standard can be re certified on site This avoids removing the system from service for recalibration Also several working RF Power Transfer Standards can be re certified using one Primary RF Power Transfer Standard Re certification can be accomplished automatically in less than 2 hours The Model M1110 becomes the certifying element and must be periodically annual calibration recommended sent to a calibration facility such as TEGAM the National Institute of Standards and Technology NIST or any equivalent service outside the USA The Model 1806 is a Dual Type IV Power Meter and Power Transfer Standard temperature controller combination Metering circuits indicate the status of both the power meters and the temperature of the Standard
7. HF Power Sensor Calibrator 1919 Half Rack Mounting Kit for Models 1805B amp 1807A 2005B 4 Terminal Chip Tweezers for 2150 2160 5 ft Length 2005B SP5132 4 Terminal Chip Tweezers for 252 253 254 5 ft Length 2 22249 2005C 4 Terminal Chip Tweezers for 2150 2160 4 ft Length 2150 VideoBridge 2150 SP5240 VideoBridge with 200V External Bias Option 2160 VideoBridge 20Hz to 150KHz Microcassette Drive 2160 SP5240 VideoBridge with 200V External Bias Option 2340 Single Channel High Voltage Amplifier 2350 Dual Channel High Voltage Amplifier 2400 Shipping Case for Arbitrary Waveform Generators 2411B 16 Bit True AWG 2414B AWG with Extended MONIOLY deae son ito es 2416A High Speed AWG 2600 Digital LCR Meter 2610 Digital LCR Meter with GPIB Interface 2711A Low Cost 16 Bit AWG 2714A Low Cost AWG with Extended Memory 3101 Waveform Generator 3102 Waveform Generator 3525 General Purpose Programmable LCR Meter F 1 3550 High Frequency Programmable LCR Meter F 3 5000 Carrying Case for 840 amp 850 Series Calibrators and 819 amp 820 Series Thermometers D 2 gy 9 DIJO pe 3502282 shoe ERZ3S s pEE RAS 9 2524 NI eee eee 9 cnn
8. Model 1806 Dual Type IV Power Meter BIAS Model M1110 Power Standard Temp Leer E Control T Digital Voltmeter IEEE 488 BUS RF Power Transfer Standards and the Model 1805B may be used in a bench or rack mount configuration All of these models are half rack instruments and can be mounted side by side or individually using rack mount kit number 1919 NIST Traceability The figure below shows the traceability to NIST of the System IIA The M1110 is a Primary RF Power Transfer Standard and the F1109 is a working RF Transfer Standard The working or feedthrough RF Transfer Standard can be returned to TEGAM for calibration using a NIST calibrated Primary RF Power Transfer Standard as shown by the path on the right To keep the working RF Power Transfer Standard in your lab a Primary RF Power Transfer Standard can be purchased to re calibrate it The Primary RF Power Transfer Standard can be sent directly to NIST for annual calibration as depicted by the path on the right It can also be sent to TEGAM as depicted by the path on the left Cost and turnaround times are significantly reduced by sending the Primary RF Power Transfer standard to TEGAM The System IIA comes in a variety of packages Contact TEGAM for more information Reference Laboratory System IIA L mmm EE M A ee User Power Sensor Recalibrated System IIA L or any o
9. Operating Environment 64 4 82 4 F 18 28 C lt 80 RH Non Condensing Double the measurement errors for conditions outside of this range but within 41 0 104 F 5 40 C Storage Environment 32 122 F 0 50 C lt 80 RH Non Condensing Power Requirements user selectable 100 120 220 amp 240 VAC 10 MAX 250VAC 50 60Hz Consumption 40VA MAX Dimensions 9 85 X 5 83 X 15 75 250 X 148 X 400 mm WXHXD Weight 15 5lb 7 0 kg Approximate Weight Included Accessories Operation Manual PN 3553 9000 1CD Power Cord PN 161006600 Options Chip Tweezers PN 2005B Chip Test Fixture PN 3511 Kelvin Klips PN 47454 Radial Lead Adapter PN 3510 GPIB IEEE 488 Interface PN 3505 This data sheet was current when it was produced However products are constantly being updated and improved Because of this some differences may occur between the descriptions herein and the current product Prices and specifications may be changed without notice TEGAM YOUR GLOBAL SOURCE FOR TEST AND MEASUREMENT SOLUTIONS BACK TO CONTENTS TEN TEGAM WAY GENEVA OHIO 44041 440 466 6100 FAX 440 466 6110 www tegam com e mail sales tegam com Model 1750 e 100 no resolution Automatic thermal and electromagnetic noise rejection Programmable reference currents GPIB RS 232C amp RS 422 compatibility The TEGAM Model 1750 High Speed Micro Ohmmeter is the first breakt
10. parallel value relative to either the series value or the parallel value can be found to better than 1 ppm by making a 1 1 comparison with the remaining tenth resistor and a simple calculation The accuracy and precision of the individual resistors also make the Model SR1010 ideal for use as a multi value stan dard resistor or reference voltage divider SR 1010 TEGAM ft YOUR GLOBAL SOURCE FOR TEST AND MEASUREMENT SOLUTIONS C 5 Model SR1010 RESISTANCE TRANSFER STANDARD Specifications Standard Values 1 10 100 Q2 step 1 10 100 k Q step Accuracy Transfer 1 ppm 0 1uQ at parallel value for 100 1 transfer 1 ppm 1uQ at series parallel value for 10 1 transfer Calibration Conditions 23 C low power four terminal measurement Temperature Coefficient 5 ppm C matched within 3 ppm C for 100 Q and higher ppm for 10 Q 15 ppm C matched within 5ppm C for 1 Q Power Coefficient Breakdown Voltage 1500 V peak to case Leakage Resistance Greater than 10 Q from terminal to case Calibration Data Initial calibration readings are affixed to instrument Dimensions Height 4 4 in 11 20 cm Width 12 2 in 31 00 cm Initial 20 ppm of nominal 0 1 ppm mW per resistor for 100 Q Depth 4 0 in 10 15 cm value matched within and higher Weight 10 ppm 0 02 ppm mW per resistor for 10 Q 3 25 Ib 1 5 kg Long Term 50 ppm of nominal 0
11. Linearity errors are given in parts per mil lion ppm of input Verification of lineari ty errors is traceable to N I S T uncertainty of 0 5 ppm of input Number of Decades 0 35 V Hz Range Seven 2 5 V Hz Range Eight Resolution 0 35 V Hz Range 0 1 ppm of input 2 5 V Hz Range 0 01 ppm of input Range 0 35 V Hz Range 0 0010000 to 1 0009999 2 5 V Hz Range 0 00010000 to 1 00009999 Frequency Range 50 Hz to 20 kHz standard 10 Hz to 1 kHz 2 5 V Hz Maximum Phase Shift 0 35 V Hz Range 10 Hz to 100 Hz 50 urad to 5 mrad 100 Hz 100 Hz to 20 kHz 50 urad at 1 KHz to 1 mrad at 20 kHz Multiply specifications x 4 for 2 5 V Hz option Maximum Input Voltage 0 35 V RMS Hz 350 V maximum 2 5 V RMS Hz 350 V maximum option al Maximum Input Current For best performance no DC current should be permitted DC input of 20 uA will decrease AC input voltage rating about 10 and increase distortion slight ly 200 uA causes near saturation of core and serious errors Input Impedance 0 35 V Hz Range gt 40 kQ 50 Hz to 1 kHz 2 5 V Hz Range 100 kO 10 Hz to 100 Hz Above 100 Hz 100 kQ decreasing with frequency Applies for inputs 10 V RMS Input Inductance 0 35 V Hz Approx 100 to 400 H depending on excitation 2 5 V Hz Approx 700 H to 2 1 kH depending on excitation Output Current 100 mA maximum Input Capacitance 0 35 V Hz Range 2 nF typical 2 5 V Hz Range 12 nF
12. Resistance is front panel switch selectable to accommodate either 100 or 200 ohm thermistor Standards The 1806 measures dc power levels from 0 01 to 30 mW Used in conjunction with a TEGAM RF Power Transfer Standard and an external digital voltmeter the Model 1806 serves as a precision power meter for measuring RF power levels and for transferring calibration factors between feedthrough Standards or thermistor type sensors Additionally the Model 1806 is ideal for performing insertion loss measurements up to 20 dB Regardless of the application all measurements can be directly traced to primary NIST standards The 1806 can be used with all TEGAM RF Power Transfer Standards and can also be used in place of an HP Agilent Model 432 with HP Agilent thermistor power sensor Models 478A 8478A and 486A TEGAM cable 138 652 required The TEGAM Primary RF Power Transfer Standard is a terminating thermistor mount that can be used to calibrate the reference output found on many power meters which serve thermocouple and diode power sensors Operating Flexibility TEGAM Coaxial RF Power Transfer Standards are available for a wide variety of frequency ranges from 100 KHz to 26 5 GHz Waveguide RF Power Transfer Standards are available in the 26 5 to 40 GHz range See the individual Transfer Standards datasheets for details The TEGAM Model 1806 fits a 19 inch rack It may also be used on the bench All of the TEGAM feedthrough
13. Type K Surface 8716 Temperature Probe T C Type K Air Gas 8723 Temperature Probe T C Type J General Purpose Immersion uu scRz r9 xxx wns 8733 Temperature Probe T C Type K Compact General Purpose Immersion 8734 Temperature Probe T C Type K Compact Penetration 8736 Temperature Probe T C Type K Compact Air Gas 8737A Temperature Probe T C Type K Griddle 8753 Temperature Probe T C Type T General Purpose Immersion 8850 HF Attenuation Measurement System 8850 01 8850 with Signal Source 2 ieccagco eue y ead acs 8850 02 8850 with Signal Source and Computer 8852 RF Frequency Converter O BOH otis Hs es ee eee ee 8853 RF Frequency Converter 18 40GHZ 12501 Alligator Clip Adaptor for 110A 120 122 8 125 iso xs 12502 Universal Adaptor for 110A 120 122 amp 125 13325 Sorting Fixture Contact Replacement Kit for 1304 1717 17503 and 32001 4 pens G 4 17501 Kelvin Klip Lead Set 3 Feet Long for 1750 G 4 17502 Spade Lug Lead Set 3 Feet Long Jor 1750 2435 ache RS ETE G 4 17503 Sorting Fixture for 1750 G 4 17504 Kelvin Probes for 1750 G 4 17505 Male LEMO Connector amp Strain Relief for 1750 G 4 17508 Calibration Standard for 1750 EC G 4 43072 Kelvin Klips for 252
14. Your Global Source for Test and Measurement Solutions ince 1979 TEGAM Inc has been your global source for test and measurement solutions We enter into our 25th year confident that we will continue to grow in revenue and reach as a world leader in the test measurement amp calibration field We are proud of our unique application specific products which are used by most of the Fortune 1000 and also of our unprecedented customer service TEGAM s goal is to create and maintain long term relationships with our customers We achieve this goal by our incomparable responsiveness to customer needs and with honest straightforward communication Every TEGAM Teammate is empowered and expected to take care of you our customer We have all seen dramatic changes in the electronics industry over the last few years TEGAM s focus on product development and attention to our customers have resulted in continued growth during these difficult times Today TEGAM is launching more new products than any of our competitors In this catalog you will find many innovative solutions including NEW low cost RF power sensor calibrators NEW extended frequency range RF power standards NEW high performance LCR meters NEW arbitrary waveform generators and voltage amplifiers for MEMS testing applications and much more These new products all outperform previous models and cost less to purchase operate and maintain I sincerely hop
15. e mail sales tegam com Model SR1010 Accuracy of transfer better than 1 ppm e Six models decade values from 1 Q step to 100k O step e Establish decade resistances from 0 10 to 1MO Calibration readings traceable to NIST are provided Prices and specifications subject to change without notice DS amp INSTRUMENTS Resistance Transfer Standard The SR1010 meets or exceeds all of the requirements for resistance transfer standards in precision measurement appli cations It is easily configured to transfer resistances up or down a decade from their initial resistance value When used with the connecting networks and shorting bars it provides 1 ppm transfer accuracies Each transfer standard contains twelve equal value precision resistors connected in series by specially designed true 4 terminal junctions These special junctions assure that a 4 terminal mea surement of a series of resistors agrees with the sums of the individual resistors in the series Accurate parallel connec tions can be made with the Parallel Compensation Network and the Shorting Bars connected to the junctions BACK TO CONTENTS These standards can be connected to provide three decade values 10 resistors in series IOR 9 resistors in series par allel IR and 10 resistors in parallel R 10 The part per million accuracy is assured as the series value is equal to 100 times the parallel value to better than 1 ppm The series
16. 253 254 43374 Dust Cover for 252 253 254 47422 Tweezer Tip Replacement Kit 12 tips for 2005B 2005C amp TVWW2600 ten ctassesetevedeunsndes 47454 Kelvin Klips 5 Terminal 2150 2100 s 0tdiwe need nube REO a RR 9 70161 2 5 V Hz Option for PRT73 ee eee C 22 70192 Rack Mount Kit for PRT 73 sci0eShenedawebde seeded C 22 70193 Rear Panel Terminals for PRT 73 een C 22 80010 AC Adapter Battery Charger for Model 820 Through 855 D 2 80135 T C Type K Velcro Wrap Around Sensor 9 80141 Ext Cable T C Type K Stranded Wire 3 Feet D 2 82814 Temperature Probe Thermistor Extra Duty Penetration esee l 6 83105 Temperature Probe T C Type K High Temperature Right Angle Surface Probe 83115 Temperature Probe T C Type K High Temperature Surface PODE eese mens debe heeds rni aceues 83804 Temperature Probe Thermistor Heavy Duty Penetration ets arietis pariuk EE 85105 Replacement Sensor for 900 Aor Pr 85115 Replacement Sensor Element for900AorB 86104 12 Temperature Probe T C Type K Pistol Grip Penetration 12 000 l 2 86104 18 Pistol Grip 18 l 2 86104 24 Pistol Grip 24 l 2 200020A WaveWorks Pro Waveform Creation Software E 15 15030901 9 15031001 Comparator Head for Co011 uoueduce kein eee
17. All crowns will mate nondestructively with connectors per MIL STD 39012 refer to Weinschel PLANAR CROWN data sheet for more details TEGAM YOUR GLOBAL SOURCE FOR TEST AND MEASUREMENT SOLUTIONS B 5 B 6 FREQUENCY CONVERTER Specifications Frequency Range Signal port 18 to 40 GHz RF In 6 to 13 333 GHz LO In 5 99 to 13 323 GHz IF Out 30 2 MHz RF Signal Levels RF Input 5 dBm nominal 10 dBm maximum LO Input 7 2 dBm 10 dBm maximum Signal Port 2 dBm maximum 10 dBm minimum Nominal Impedance 50 Q Input Load SWR lt 1 6 Connectors RF Input SMA Female LO Input SMA Female 30 MHz OUTPUT Type N Female Test Port PLANAR CROWN 2 92 mm Female Signal Port PLANAR CROWN 2 92 mm Female Subharmonic 55 dBm Warm up Period 3 hours minimum Input Power Requirements 100 120 220 240 Vac 10 50 to 60 Hz Power Consumption 180 Watts Design and Construction Designed to meet requirements of MIL STD 28800D TYPE III CLASS 5 STYLE E Temperature Operating 10 to 40 C 450 to 104 F Storage 40 to 75 C 40 to 167 F Humidity 05 Physical Dimensions Height 3 5 in 88 9 mm Width 16 75 in 425 mm standard rack width Depth 20 in 520 7mm Weight NET 23 5 Ibs 10 66 kg COMPUTER IEEEE 488 BUS Frequency Converter Model 8853 Signal Generator Model VM 7 59853 FREQUENCY CONVERTER 30 MHz IN Frequency Converter Model 8852 2 to 18 GHz AUX OUT
18. BACK TO CONTENTS TEN TEGAM WAY GENEVA OHIO 44041 440 466 6100 FAX 440 466 6110 www tegam com e mail sales tegam com Model 8850 E 40 GHz e Fast and accurate e Easy to use manually or with CAMLab software Optional A2LA accredited calibrations Prices and specifications subject to change without notice SUREMENT Attenuation Measurement System The Model 8850 Attenuation Measurement System combines the out standing accuracy performance high sensitivity and reliability of our Model VM 7 Attenuator and Signal Calibrator with our Model 8852 0 01 to 18 GHz Frequency Converter When combined with a suitable generator the Model 8850 provides the user with an attenuation calibration system of high accuracy repeatability and speed Some other features of this system include e ADVANCED TECHNIQUES Advanced digital processing techniques of the VM 7 means detection and that measurements are available instantaneously no matter what the dynamic range or resolution SINGLE BAND OPERATION The system can be converted to a 0 01 to 18 GHz single port converter This is accomplished by using the measurement BACK TO CONTENTS accessory kit P N 187 4001 that is supplied as part of the system The measurement accessory kit includes low SWR masking attenuators and a power divider to provide a measurement system as shown in Figure 1 DUAL BAND OPERATION The RF input frequency range
19. DIGITAL THERM Wire Thermocouple Probes For gas surface or liquid measurements a g These 3 ft long probes have fiberglass insulated 24 ga wires welded at the tips lt a 6 ft long 8712 6 Time constant 1 sec Accuracy 2 2 C or 0 75 TC TYPE MAXTEMP MODEL K 900 F 480 C 8712 K 900 F 480 C 8712 6 LZ General Purpose Probes For measuring liquids gases or small area surfaces Sheath 304 SS 3 ft vinyl clad straight cord Time constant 1 sec Accuracy 2 2 C or 0 75 TC TYPE MAX TEMP MODFEL K 1650 F 900 C 8713 2 J 1400 F 760 C 8723 FC oL 1 16 4 n Penetration Probes Ideal for measurement of meats plastics and other semi soft materials Sheath 304 SS 11 5 ft ext 5 ft coil cord with Thermoplastic Rubber jackets Time constant 2 sec Accuracy 2 2 C or 0 75 TC TYPE MAXTEMP MODEL K 1650 F 900 C 8714A I 3 dre e Surface Probes For monitoring hot plates furnaces molds and other hot solid surfaces Exposed thermocouple junction provides quick response upon direct contact Sheath 304 SS 3 ft vinyl clad straight cord Time constant 3 sec Accuracy 2 2 C or 0 75 TC TYPE MAXTEMP MODEL t 1 4 ee Air Gas Probes For measuring atmospheres in hoods ducts and vents Perforation pattern in shield is designed to prevent radiation induced tip heating so air gas temperature measurements are more accurate Sheath 304 SS 3
20. Prices and specifications subject to change without notice DS amp INSTRUMENTS Dekabox Coaxial Dial Decade Resistor The Model DB877 Dekabox Decade Resistor provides dependable long term service in precision DC through audio frequency applications Eight decades of non inductive precision wire wound fixed resistors are mounted in a low noise shielded metal case that also provides good mechanical protection The DB877 is easy to use It has the input terminals and a case connected ground terminal conveniently located on the front panel The dials rotate independently through 360 degrees and a special detent design facilitates dial TOTAL 12 wicouns BACK TO CONTENTS location This allows for a coarse approximation and then precise finer steps to provide an exact resistance value Accuracy over a wide range of ambient conditions is assured by the use of resistors with good temperature and power coefficients Repeatability is assured by the use of switches that have multiple contacts of solid silver alloy and silicone treated ceramic wafers Resistance per step and current ratings on each decade are presented below the dials for operator convenience and circuit safety MODEL 08877 TEGAM YOUR GLOBAL SOURCE FOR TEST AND MEASUREMENT SOLUTIONS C 13 C 14 Model DB877 DEKABOX COAXIAL DIAL DECADE RESISTOR Specifications Accuracy Short Term Switching Repeatability Resistance per D
21. Weight Power TEGAM YOUR GLOBAL SOURCE FOR TEST AND MEASUREMENT SOLUTIONS harmonic graphic display and tabulation Waveform and digital pattern Point Vertex and Harmonics FFT and IFFT 19 2k Baud max IEEE Std 488 2 1987 73 4 F 5 4 F 23 C 3 C for specified accuracy 32 F to 122 F 0 C to 50 C 4 F to 140 F 20 C to 60 C 10 14 X 4 53 X 11 81 25 8 X 11 5 X 30cm WxHxD 11 Ibs 5 0kg 55VA 45W max 100 120 220 240VAC 4596 10 48 to 63Hz BACK TO CONTENTS TEN TEGAM WAY GENEVA OHIO 44041 440 466 6100 FAX 440 466 6110 www tegam com e mail sales tegam com Model 2714A GENERATORS Low Cost AWG with Extended Memory 10 Standard Waveforms e 128k Waveform Memory Stores 100 Custom Waveforms 0 06 Waveform Distortion e RS 232C and GPIB Options 100 Step Sequence Generator Rack Mount Kit Signal Integrity Waveforms are always consistent and repeatable because the 2714A is a true arbitrary waveform generator It uses the raster scan technique with sequential addressing of waveform memory and a variable sample clock rate to adjust the output frequency Other generators use phase accumulator based addressing which can skip or repeat waveform data points The typical THD total harmonic distortion plus noise of the 2714A is 65 dB No other arbitrary waveform generator matches the 2714A s price and performance Comprehensive Fe
22. With four sync outputs available from each slave 16 total outputs numerous instruments can be simultaneously triggered by a single waveform event Further expansion is limited only by propagation delay Warranty The Model 2414B is backed by a full 3 year warranty and TEGAM s 30 day no risk trial TEGAM YOUR GLOBAL SOURCE FOR TEST AND MEASUREMENT SOLUTIONS E 4 Model 2414B AWG WITH EXTENDED MEMORY Specifications Output Waveforms Up to 1 000 custom waveforms Sine Square Triangle Sawtooth DC Pulse Exponential AM SCM FM Lin Log Sweep Sin x x Sinc Gaussian Haversine Circle Noise 4 programmable sync signals per waveform Sequence Generator Optional Waveform Repetitions Program File Waveform Storage Resolution Sample Rate Transition Time Transient free Loop and Link Loop 1 048 575 times Link 1 000 waveforms 4 096 Steps total 100 Sequences 1 000 Waveforms Horizontal Points 128k 131 040 max Vertical Points 12 bits 4 096 2 047 2 048 0 1Hz to 20MHz 10s to 50ns 4 1 2 digit resolution 10ppm accuracy 20ns Tested with square wave filter off 10Vp p 50 2 termination Spectral Purity THD Noise 65 dB typical Tested with SOKHz measurement bandwidth 20M Hz clock 20 kHz sine wave 1 000 points filter on full amplitude 50 2 termination Amplitude and Offset Range Resolution Accuracy 1 00 to 10V 10
23. are displayed on the front panel and are changed using front panel switches This seven decade AC voltage divider gives 0 1 ppm resolution for ratio set tings from 0 0010000 to 1 0009999 and terminal linearity of 0 9 ppm It performs over a wide range of frequencies from 50 Hz to 20 kHz with maximum input volt age of 0 35 V Hz up to 350 V For greater flexibility the Low Frequency Option extends voltage capability to 2 5 V Hz from 10 Hz to 1 kHz This option expands ratio measurement capabilities to include 150 V at 60 Hz and adds another trans former improving resolution to 0 01 ppm Prices and specifications subject to change without notice BACK TO CONTENTS TEGAM ft YOUR GLOBAL SOURCE FOR TEST AND MEASUREMENT SOLUTIONS C 22 Model PRI 73 AUTOMATED PRECISION RATIO TRANSFORMER Specifications Linearity Error 3 Terminal 0 35 V Hz Range 50 Hz to 1 0 kHz 0 9 ppm for settings 0 1 to 1 0000999 0 9 V 10 x setting 0 01 ppm For settings 0 01 to 0 1 200 Hz to 1 kHz 0 9 V 10 x setting 0 01 ppm For settings 0 001 to 0 01 50 Hz to 200 Hz 0 9 N 100 x setting 0 01 ppm For settings 0 001 to 0 01 2 5 V Hz Range 50 Hz to 400 Hz 1 ppm 0 9 ppm x Ratio 400 Hz to 1 kHz Multiply 50 Hz to 400 Hz values by factor of f 400 where f frequency in Hz 10 Hz to 50 Hz Multiply 50 Hz to 400 kHz values by factor of 50 f where f frequency in kHz
24. runs once Gated As triggered except output is continous until gate signal ends Burst Each trigger outputs a preprogrammed number of waveforms from 1 to 1 048 575 Toggled Alternate triggers gate the output waveform Master Slave For multi unit operation Cont Sync Multiple units run continuously in sync with the master unit Trig Sync Multiple units run in sync with the master unit for one cycle when the master unit is triggered A tail chasing mode between the master and the slave unit initiated by triggering the master unit Trig Seq This data sheet was current when it was produced However products are constantly being updated and improved Because of this some differences may occur between the descriptions herein and the current product Prices and specifications may be changed without notice TEGAM Outputs Main Output Sync Output Clock Out Reference Out Sync Trigger Out Inputs TRIG IN CLOCK IN REF IN Trigger Sources Manual Trigger Ext Trigger Input Creation Tools Front panel S0Q impedance Front panel TTL sync output 50Q impedance Rear panel AWG waveform sample clock output TTL X2 sample clock Rear panel internal 10MHz reference output TTL Rear panel BNC TTL for multiple unit operation Rear panel TTL trigger input for triggered gated toggled burst and master slave modes Rear panel sample clock input TTL 20MHz Rear panel 10 MH
25. yet replaceable The probes feature unique safety resistors and shock collars With the best overall protection in the business TEGAM meters won t blow up or melt down All models are Underwriters Laboratories approved The original Model 110A Safety Voltmeter is designed for voltage troubleshooting With a range of 1 000 volts it s more versatile than the Wiggy and more accurate than the Simpson 260 It has 1M ohms of resistance in each lead to protect the user and is designed to take 2 500 volts and keep on working This meter is ideal for line clearing and TPM and Skills Transfer programs Customers have reported huge cost savings including thousands of man hours of productivity improvements and reduction of electrical accidents Meets Category III Overvoltage SPECIFICATIONS protection under UL 3111 1 IEC 1010 1 The Voltman eliminates phantom voltage readings This Model 120 represses capacitance effects that occur during utility meter based checks and other situations where powered and unpowered cables are in close proximity It verifies line voltages from 0 750 volts while preventing false readings This boosts productivity of meter installers and repair personnel by eliminating guesswork If you need a continuity function or if harmonics are a problem the Voltman TRMS is for you Non sinusoidal waveforms from variable speed motors cause problems for most voltmeters but the Model 125 provides accurate depend
26. 26 5 GHz 1 50 from 10 to 20 MHz 1 40 from 20 to 50 MHz 1 30 from 50 to 100 MHz 1 20 from 0 1 to 4 GHz 1 30 from 4 to 8 GHz 1 40 from 8 to 14 GHz 1 60 from 14 to 26 5 GHz Power Linearity 0 190 from 1 to 10 mW lt 0 1 from 1 to 10 mW Insertion Loss 6 dB 10 5 dB max 2 dB max Individual calibrations traceable to NIST supplied at the following frequencies 10 to 100 MHz in 10 MHz steps 100 MHz to 2 GHz in 50 MHz steps 2 GHz to 4 GHz in 100 MHz steps 4 to 12 4 GHz in 200 MHz steps 12 75 to 18 GHz in 250 MHz steps 18 to 26 GHz in 1 GHz steps 26 5 GHz 10 to 100 MHz in 10 MHz steps 100 MHz to 2 GHz in 50 MHz steps 2 GHz to 4 GHz in 100 MHz steps 4 to 12 4 GHz in 200 MHz steps 12 75 to 18 GHz in 250 MHz steps 18 to 26 GHz in 1 GHz steps 26 5 GHz Calibration Factor Accuracy 1 00 from 0 01 to 10 GHz 1 10 from 10 to 18 GHz 2 20 from 18 to 26 5 GHz 1 20 from 0 01 to 10 GHz 1 30 from 10 to 18 GHz 2 30 from 18 to 26 5 GHz Calibration Factor Drift 0 5946 per year 0 596 per year Thermistor DC Bias Power 30 0 7 mW 30 0 7 mW Thermistor Resistance at Bias 200 Ohms 200 Ohms Thermistor Power Sensitivity Approximately 13 Ohms mW Approximately 13 Ohms mW Temperature Operating Storage 12 to 40 C 454 to 104 F 55 to 75 C 67 to 167 F 12 to 40 C 454 to 104 F 55 to 75 C 67 to 167 F Warm up time 2 h
27. 3 ppm mW per resistor for 1 Q Standard Equipment E value Maximum Power Rating The SR1010 comes with an Calibration 10 ppm 1W step or 5 W distributed over 10 8502 instruction manual resistors R Value Per Step 19 100 1000 1kQ 10kQ 100kQ One max mA 1000 320 100 32 10 3 2 Resistor Alone max V 1 3 2 10 32 100 321 10 Resistors max mA 7100 2300 710 230 71 23 in Parallel R 10 max V 0 71 2 3 7 1 23 71 230 10 Resistors max mA 710 230 71 23 7 1 2 3 in Series 10R max V rd 23 71 230 710 2300 10 Q standard is SR1010 LTC Do not exceed 1500 V to case With Model SB103 and Model PC101 or SPC102 GRD ai a a ee Se ee Le Initial Accuracy The specifications stated in the TEGAM instrument catalogs and data sheets are intended as acceptance specifications and are guaranteed for 60 days from the date of shipment They are typically maintained for a much longer period of time Long Term Accuracy These specifications are guaranteed for the standard warranty period and are typically maintained for the life of the instrument Long term accuracy is implied when not otherwise stated Calibration Accuracy Calibration accuracy is the accuracy of TEGAM calibration data relative to the legal units maintained by the U S National Institute of Standards and Technology This data sheet was current when it was produced However products are constantly being updated and improved Because of this some differences may occur between
28. 9 20 0 020 5 I 3 3 8 4 3 153 I p D i o l D i I 10 kQ j M i 1 0 10 ko 25 LS 1200 A 20 DM 02 no mu 1 1 KQ 1 Q 04 1 _ 1 Q 1 i 0 0 0 0 0 l o o o o o SEED E E SE MCCC KS MT NCDMNOC MOON Mer ENM Cu OKSDMMONEVESUNM dE J Standard Equipment Calibration amp Technical Services Model DB877 comes with a 19199 For warranty and remedial repair calibration instruction manual services and spare parts or for additional information on TEGAM sales and service offices around the world contact us at 440 466 6100 ph or 440 466 6110 fx This data sheet was current when it was produced However products are constantly being updated and improved Because of this some differences may occur between the descriptions herein and the current product Prices and specifications may be changed without notice BACK TO CONTENTS TEGAM TEN TEGAM WAY GENEVA OHIO 44041 YOUR GLOBAL SOURCE FOR TEST 440 466 6100 FAX 440 466 6110 AND MEASUREMENT SOLUTIONS www tegam com e mail sales tegam com Models DP 1211 D Kelvin Varley voltage divider Panel mounting area from 27 1 to 45 2 cm Precision resistors throughout e Solid silver alloy switch contacts Prices and specifications subject to change without notice DS amp INSTRUMENTS Dekapot Coaxial Dial Decade Potentiometer These Dekapot potentiometers are precision decade resistive voltage dividers featuring th
29. C 13 DC5010 Counter Timer DCS0SA 244 62siunbdeeenessae teed DM511 Digital Multimeter DM5110 Digital Multimeter DP1211 1K 1 K ohm Coaxial Dial Decade Potentiometer C 15 DP1211 10K 10 K ohm Coaxial Dial Decade Potentiometer C 15 DP1311 1K 1 K ohm Coaxial Decade Potentiometer C 15 DP13110 10K 10 K ohm Coaxial Decade Potentiometer C 15 DS1463 XX 9 DS1464 XX 9 DSB 1524U 9 DSHB 5C 22 2 xri e x ene RU 9 DSRB 5CD 9 DSRB 5CDA 4 Decade Synchro Resolver Bridge DSRB 5D DSRS 5 DSRS OC icin cbse cider ber edes DSHS 5D DSRS 5DA Decade Synchro Resolver Standard DSRS5DA R Decade Synchro Resolver Standard with Rack Mount DT58 anaa eh oe Gta ee eee DT72A Decade Transformer Voltage Divider cau 23 anos ace are are C 17 DT1135 saa iascndc eiie DT1145 Decade Ratio Transformer C 19 F1109 RF Power Standard 0 01 48GHz len A 5 F1109H HF Power Standard 0 01 18GHz High Power A 5 F1116 RF Power Standard 100KHz 100MHz F1117A RF Power Standard 0 05 26 5GHz 0000 eee F1117AC F1117A Power Standard Mounted in an Enclosure
30. Calibration Factor Drift 0 5946 per year 0 596 per year Thermistor DC Bias Power 30 0 7 mW 30 0 7 mW Thermistor Resistance at Bias 200 Ohms 200 Ohms Thermistor Power Sensitivity Approximately 13 Ohms mW Approximately 13 Ohms mW Temperature Operating Storage 12 to 40 C 454 to 104 F 55 to 75 C 67 to 167 F 12 to 40 C 454 to 104 F 55 to 75 C 67 to 167 F Warm up time 2 hours 2 hours Weight 5 5 Ibs 2 5 kg 3 22 Ibs 1 46 kg Physical Dimensions Height Width Depth 3 5 in 88 9 mm 8 5 in 215 9 mm 15 4 in 390 7 mm 2 88 in 73 15 mm 4 00 in 101 6 mm 9 25 in 234 95 mm This data sheet was current when it was produced However products are constantly being updated and improved Because of this some differences may occur between the descriptions herein and the current product Prices and specifications may be changed without notice A 1 0 Certificate no 2018 01 Uem YOUR GLOBAL SOURCE FOR TEST AND MEASUHEMENT SOLUTIONS BACK TO CONTENTS TEN TEGAM WAY GENEVA OHIO 44041 440 466 6100 FAX 440 466 6110 www tegam com e mail sales tegam com Model F1135 M11 MEASUREMENT PRODUCTS Coaxial RF Power Thermistor Standards are temperature controlled 0 01 to 25 mW dynamic range Primary and Working Transfer Standard configurations e Rack mount kit available e Optional A
31. DUDenstole adt cal o 25 8 X 11 5 X 30cm WxHxD SYNC 2 OUT Rear panel BNC TTL Weieht 11 Ibs 5 0kg SYNC 3 OUT Rear panel BNC TTL m i SYNC 4 OUT Rear panel BNC TTL FON UU bid dd 100 120 220 240VAC CLOCK IN OUT Rear panel sample clock I O TTL 5 10 48 to 63Hz ee Rear panel internal or external This data sheet was current when it was produced However products are IOMEZ reference TTL constantly being updated and improved Because of this some differences Sync Trigger Out Rear panel BNC TTL for may occur between the descriptions herein and the current product Prices and multiple unit operation specifications may be changed without notice BACK TO CONTENTS amp TEN TEGAM WAY GENEVA OHIO 44041 TEG A M 440 466 6100 FAX 440 466 6110 www tegam com e mail sales tegam com YOUR GLOBAL SOURCE FOR TEST AND MEASUREMENT SOLUTIONS Model 2414B Stores 1000 Custom Waveforms e Summing Input 0 06 Waveform Distortion e RS 232C Options 4 096 Step Sequence Generator WaveWorks Pro Waveform Creation Software GPIB Communications Rack Mount Kit Signal Integrity Waveforms will always be consistent and repeatable because the 2414B is a true Arbitrary Waveform Generator It uses the raster scan technique with sequential addressing of waveform memory and a variable sample clock rate to adjust the output frequency Other generators use phase accumulator based addressing which
32. LO 5 99 to 13 323 GHz Figure 1 8850 8853 16 40 GHz Measurement System This data sheet was current when it was produced However products are constantly being updated and improved Because of this some differences may occur between the descriptions herein and the current product Prices and specifications may be changed without notice BACK TO CONTENTS TEN TEGAM WAY GENEVA OHIO 44041 440 466 6100 FAX 440 466 6110 www tegam com e mail sales tegam com TEGAM YOUR GLOBAL SOURCE FOR TEST AND MEASUREMENT SOLUTIONS analysis capability User friendy icons and menus User can easily create an RF signal generator driver e All data is saved in ASCII text format e Measurements are displayed both graphically and numerically The TEGAM Calibration and Attenuation Measurement Lab CAMLab is application specific software that runs in the Microsoft Windows environment on IBM compatible PC s The CAMLab program significantly enhances the operation of the Model 8850 Attenuation Measurement system by providing the technician with automated measurement data collection data display and analysis capability The capability to save and recall complicated system instrumentation and test configurations coupled with the graphical environment of Windows M makes CAMLab easy to use by any level of personnel The CAMLab software can be configured to operate and control all system instrumentation to perform automated measur
33. NEMA Housing e RHT 20C 4 to 20ma or RHT 10V 0 to 1V Outputs RH TRANSMITTER Smallest Size Wall Mount NEMA Housing Low Cost Relative Humidity 3 RH to 95 RH range at 2 RH accuracy Temperature compensated 10 F to 175 F Temperature 20 C to 75 C A F to 167 F 0 6 C 1 F accuracy for 4 to 20ma or O to 1V output Input Voltage Range 6 to 30VDC polarity protected for both e RH 20C 4 to 20ma or RH 10V 0 to 1V Outputs current and voltage output units RH Output 4 to 20 ma or 0 to 1V represents 0 to 100 RH Response Time Under 10 seconds HUMITRAN RHS SERIES HUMIDITY CONTROLLER Quality relative humidity set point controller Stainless steel probe 4 7 long x 3 4 diameter e State of the art thin film polymer sensor Accuracy 3 RH from 3 to 95 RH Operating Temperature Range Probe 20 to 85 C Controller 0 to 75 C Recorder Output 10mV RH 50mV RH with resistor removed Controller Output SPDT Form C Relay SAMPS 250 VAC Recorder output of 0 to 1V or 0 to 5V for 0 to 100 RH input Bandwidth Control 0 to 20 RH independent of Setpoint setting Power 8VDC to 30 VDC at 125 milliamps maximum Probe Stainless steel 75 diameter 4 7 long 5 2 wire cable with bracket for wall mounting Enclosure Controller mounted in standard metal T box 4 5 x 2 75 x 2 deep screw terminal connectors HUMITRAN HT SERIES HIGH TEMPERAT
34. NIST supplied at the following frequencies 10 to 100 MHz in 10 MHz steps 100 MHz to 2 GHz in 50 MHz steps 2 GHz to 4 GHz in 100 MHz steps 4 to 12 4 GHz in 200 MHz steps 12 75 to 18 GHz in 250 MHz steps 10 to 100 MHz in 10 MHz steps 100 MHz to 2 GHz in 50 MHz steps 2 GHz to 4 GHz in 100 MHz steps 4 to 12 4 GHz in 200 MHz steps 12 75 to 18 GHz in 250 MHz steps Calibration Factor Accuracy 1 00 from 0 01 to 10 GHz 1 10 from 10 to 18 GHz 1 20 from 0 01 to 10 GHz 1 30 from 10 to 18 GHz Calibration Factor Drift lt 0 5 per year 0 596 per year Thermistor DC Bias Power 30 0 7 mW 30 0 7 mW Thermistor Resistance at Bias 200 Ohms 200 Ohms Thermistor Power Sensitivity Approximately 13 Ohms mW Approximately 13 Ohms mW Temperature Operating Storage 12 to 40 C 454 to 104 F 55 to 75 C 67 to 167 F 12 to 40 C 454 to 104 F 55 to 75 C 67 to 167 F Warm up time 2 hours 2 hours Weight 3 25 lbs 1 5 kg 2 875 Ibs 1 3 kg Physical Dimensions Height Width Depth 5 25 in 133 35 mm 4 00 in 101 6 mm 10 21 in 259 33 mm 5 25 in 133 35 mm 4 00 in 101 6 mm 7 45 in 189 23 mm Weight and Physical dimensions will vary for High Power or Case mounted versions This data sheet was current when it was produced However products are constantly being updated and improved Because of this some differences may
35. Output BNC Female Remote Operation All front panel functions except powerline operation can be programmed on the IEEE 488 interface bus Power Requirements 100 120 220 240 Vac 10 50 to 60 Hz Power Consumption 90 Watts Remote Programmability Compatible with IEEE 488 STD 1987 1 EMI Designed to meet MIL STD 461 for radiated emission and susceptibility Design and Construction Designed to meet requirements of MIL STD 28800D TYPE III CLASS 5 STYLE E Environmental Operating 0 to 50 C 32 to 122 F Storage 40 to 75 C 40 to 167 F Humidity 05 Physical Dimensions Height 5 25 in 133 4 mm Width 16 75 in 425 5 mm Depth 17 5 in 444 5 mm Weight Net 28 Ibs 12 7 kg ACCESSORIES Spare Module Kit P N 187 1030 This kit includes all replaceable module assemblies that can Rack Mounting This instrument can be rack mounted in any cabinet or rack designed according to MIL STD 189 or EIA RS 310 using rack mounting kit P N 187 1007 adapter ears only or 187 1008 contains chassis slides for racks up to 18 24 inches deep Maintenance Extender Cards To make it easier to verify the performance of the VM 7 TEGAM offers two maintenance extender cards as follows Part Number Type 187 1020 000 Digital 187 1021 000 Analog be easily replaced at any location Calibration Attenuation Measurement Lab Software Program This system software operates with the Window
36. RF ON OFF and substituted DC output power levels 0 5 and 1 10 mW in 1 mW steps using any PC Compatible Controller Temperature Range Operating 10 to 40 C 50 to 104 F Storage 40 C to 75 C 40 to 167 F Connectors Binding Post standard 0 75 spacing for Banana plugs Power Requirements 110 120 220 240 Vac 10 48 to 62 Hz 40 Watts Weight Net 5 9 kg 13 Ib Physical Dimensions Height 7 57 in 192 2 mm Width 8 8 in 223 5 mm Depth 17 5 in 444 5 mm Rack Mounting The Model 1805B is a half rack instrument that can be mounted in any cabinet or rack designed according to EIA RS 310 and MIL STD 189 using the Rack Adapter Kit P N 1919 This kit allows the Model 1805B to be mounted with the Model 1807A or another 1805B in the same rack mount configuration This data sheet was current when it was produced However products are constantly being updated and improved Because of this some differences may occur between the descriptions herein and the current product Prices and specifications may be changed without notice Certificate no 2018 01 BACK TO CONTENTS TEN TEGAM WAY GENEVA OHIO 44041 440 466 6100 FAX 440 466 6110 www tegam com e mail sales tegam com TEGAM YOUR GLOBAL SOURCE FOR TEST AND MEASUREMENT SOLUTIONS Model 1804 front panel Economical easy to use compact and light weight One year warranty Optional A2LA Accredited Calibr
37. SWR lt 1 6 e Rack mount kit available Prices and specifications subject to change without notice UREMENT Frequency Converter 18 to 40 GHz Extends Your VM 7 Capabilities to 40 GHz in Coax The Model 8853 Converter is intended for use with any TEGAM Model VM 7 Attenuator Signal create an 18 to 40 GHz measurement system This Frequency Converter downconverts the 18 to 40 GHz measurement signal to a 30 MHz IF signal which can be measured by the VM 7 Using the Model 8853 with the Model 8852 Frequency Converter will allow the Frequency Calibrator to user to measure attenuation from 0 01 to 40 GHz without the use of an additional LO source Figure 1 shows a typical Model 8853 Measurement System setup When used with the Model 8850 Attenuation Measurement System the Model 8853 does not require any addi tional signal sources BACK TO CONTENTS This instrument can be easily stacked with other TEGAM instruments or mount ed in any cabinet or rack designed accord ing to EIA RS 310 and MIL STD 189 using the appropriate rack mounting kit Weinschel PLANAR CROWN Connector System The use of Weinschel PLANAR CROWN connectors at the INPUT connectors provides the Model 8853 user with easy exchange of connector types and eliminates the need for adapters and other devices that would create additional insertion loss This Torque Free type of connector also provides defective quick replacement of connectors
38. TO CONTENTS E 13 E 14 WavewWorks Jr WAVEFORM CREATION SOFTWARE Standard Waveforms WaveWorks Jr offers 21 standard waveforms with parameter templates to create custom waveforms for your application The following standard waveform templates are available Sine BPSK Square Triangle DC Comb Math Transfer Function 12 transfer functions including integration and differentiation are available to process waveform data Null Linear Section DC Cut Polynomial Normalize Square Root Log Math Operator Complex waveforms are readily created by use any of the 6 different math operators Addition Subtraction Multiplication Into Add Into Cascade Waveform Analysis Synthesis Frequency Domain FFT and IFFT Harmonics up to 500th harmonic Displays graphic and tabulation Entry tabulation Units Sin Cos Ampl Sin Ampl Phase Cos Ampl Phase Sin dB Phase Cos dB Phase Other features random phase entry Time Domain Digital Pattern Display graphic Edit mouse Computer Requirements Operating Systems Windows 95 98 XP and 2000 Operating Systems PC Requirements 486DX or better processor w 4MB RAM Interfaces serial COM Port RS 232C up to 19 2k Baud GPIB National Instruments AT GPIB card IEEE standard 488 2 1987 Waveform Generators 2711A 2714A This data sheet was current when it was produced However products are constantly being updated and improved Because of this so
39. Thermometers amp Temperature Probes LEN Transportable Resistance Standards 3 Thermometers 1 Resistance Transfer Standard 5 Heavy Duty Food Processing Thermometer 2 In Line Decade Resistors 11 Thermocouple Thermometers 3 Coaxial Resistor Decade Boxes 13 Thermocouple Probes 4 G Decade Potentiometer 15 RTD Thermistor Thermometers 5 Decade Ratio Transformer Standard 17 Thermistor Probes 6 Decade Ratio Transformers 19 RTD Probes 7 Automated Precision Ratio Transformer 21 Probe amp Thermometer Accessories 8 rmm Resistance Accessories 23 Calibrators amp Switch Boxes 9 Temperature Calibrators Humidity Controllers amp Transmitters Thermocouple Calibrators Thermometers 1 RH Temperature Products 1 Thermistor Calibrators Thermometers 1 Ho RTD Calibrators Thermometers 1 Customer Service and Support Ohm Calibrators Thermometers 1 Extended Warranty Plan 1 Temperature Calibration Accessories 2 Calibration Service Plan 2 Total Service Plan 3 Repair and Calibration Services 4 Calibration Certificates amp Accreditations 5 Web Resources 6 Index by Model Number 7 Ko TEGAM assumes no responsibility for printing errors or user interpretation of specifications Prices and specifications are subject to change without notice me ad TEGAM Web www tegam com EU sales tegam com Phone 440 466 6100 Fax 440 466 6110 Mail TEGAM Inc Ten TEGAM Way Geneva OH 44041 Visit our website www tegam com To see our newest prod
40. constantly being updated and improved Because of this some differences may occur between the descriptions herein and the current product Prices and specifications may be changed without notice TEGAM YOUR GLOBAL SOURCE FOR TEST AND MEASUREMENT SOLUTIONS CA3 XXXX CA5 XX Repair and calibration by trained factory technicians PLAN FEATURES ANSI NCSL Z540 1 1994 compliant calibration at TEGAM Inc recommended intervals This includes Calibration Records Management Calibration Due Notification sent in advance of your due date A Calibration Certificate provided with each calibration As Found amp As Left Data provided with each calibration Available for NEW or previously purchased products previously purchased products may require a baseline calibration TO ORDER CA3 XXXX Calibration Service Plan PLAN BENEFITS Your instrument is regularly calibrated at recommended intervals The cost of this program is much less than the current cost of our standard calibration service You avoid future calibration service cost increases Your calibration is paid in advance and will not be subject to future budget cuts This program saves you downtime and money This program eliminates potentially critical delays caused by quotation and approval procedures Priority service scheduling is included as part of this plan Your instrument goes to the head of the line as soon as it arrives at TE
41. e ANSI NCSL Z540 1 1994 compliant calibration at TEGAM Inc recommended intervals This calibration includes Calibration Records Management Calibration Due Notification sent in advance of your due date A Calibration Certificate provided with each calibration As Found amp As Left Data provided with each calibration Additional Services Any new Software and or Firmware upgrades will be installed Any new safety and or reliability enhancements will be installed Available with qualified New Product Purchases TO ORDER TS3 XXXX PLAN BENEFITS Maintains peak instrument performance for up to five years This program allows you to pay in advance for up to five years of TOTAL SUPPORT with PREFFERED STATUS for your new instrument You receive substantial cost reductions from standard calibration and repair fees It simplifies your future budgeting process You can determine your support costs in advance You avoid future price increases for the life of the program This program saves you downtime and money This plan eliminates potentially critical delays caused by evaluation quotation and approval procedures It s renewable The TSP is the only plan that gives you the option to renew for an additional three to five years Priority service scheduling is included as part of this plan Your instrument goes to the head of the line as soon as it arrives at TEGAM XXXX is the model num
42. heavy duty temperature probe and model 874 digital thermometer The new 86104 probe features a robust pistol grip ergonomic design and a ruggedized penetration sheath to reduce user fatigue and increase durabil cessing plant applications including soups brines and especially combo box testing The 874 digital thermometer is easy to use and provides the durability and accurracy needed for food quality con trol The 874 is built with a shock proof splash proof high impact ABS case and is available in either F or C scales to make a perfect companion for the 86104 series of probes ity The 86104 is available in 12 18 and 24 lengths to suit a variety of pro Specifications MODEL TC TYPE RANGE RESOLUTION ACCURACY 874F K F 40 TO 199 9 0 1 0 5 rdg 1 F F 120 TO 199 9 r 1 rdg 2 F 874C K C 40 TO 199 9 0 1 0 5 rdg 0 5 C C 85 TO 1100 i 1 rdg 1 C Repeatability 0 3 F Dimensions 63 x 2 7 x 1 2 Display 3 h digit LCD 5 high Net weight T2302 Available in 86104 12 K 12 long Max 700 F 86104 18 K 18 long 86104 24 K 24 long 0 to 66 6 F in 3 sec 304 SS Pistol Grip 24 PVC PVC Cord with male mini TC plug Response Time Description This data sheet was current when it was produced However products are constantly being updated and improved Because of this some differences may occur between the descriptions herein and the current product Prices and
43. is a terminating thermistor Primary Transfer Standard It is designed to be calibrated directly by a national standards agency such as NIST The M1135 is used for the calibration of feedthrough devices such as bolometer mount coupler and bolometer mount splitter RF Standards It is also useful in other applications requiring direct measurement of RF power The accuracy specifications are the same as the Models M1110 and M1118 The M1135 has better VSWR from 18 to 26 5GHz Both models frequency band of any thermistor power have the widest standard commercially available This reduces the number of standards needed to calibrate power sensors in the 10 MHz to 26 5 GHz frequency range and lowers annual calibration costs by up to 50 The Model F1135 features a 3 5 mm female connector and the M1135 features a compatible 2 92 mm male connector Bias connectors are binding posts with standard 0 75 spacing for banana plugs The internal heater is connected using cables provided with the models F1135 1805B 1806 and 1820 TEGAM YOUR GLOBAL SOURCE FOR TEST AND MEASUREMENT SOLUTIONS Model F1135 M1135 A 12 COAXIAL RF POWER TRANSFER STANDARDS Specifications Frequency Range F1135 10 MHz to 26 5 GHz M1135 10 MHz to 26 5 GHz Power Range 0 01 to 25 mW 20 to 14 dBm 0 01 to 25 mW 20 to 14 dBm Nominal Impedance 50 Ohms 50 Ohms Max VSWR 1 25 from 0 01 to 18 GHz 1 35 from 18 to
44. is divided into two bands 0 01 to 2 GHz and 2 GHz to 18 GHz This allows the user direct access to the RF port of either the LOW band or HIGH band mixer to make full use of the VM 7 dynamic range IEEE 488 BUS PROGRAMMABLE programmability over the IEEE 488 bus Remote using an external controller or controlling the system using only the VM 7 AUXILIARY OUTPUT An auxiliary output of 2 to 18 GHz synthesized continuous wave signal in 2 KHz steps at 7 dBm is available which can be used as an RF signal source for other applications VERSATILE AND USER FRIENDLY This measurement system will test all types of attenuators such as fixed manual motorized programmable and other coaxial components Coaxial components can be quickly and accurately tested using the efficient user friendly CAMLab Windows software TEGAM YOUR GLOBAL SOURCE FOR TEST AND MEASUREMENT SOLUTIONS B 10 ATTENUATION MEASUREMENT SYSTEM Signal Generator 0 01 to 18 GHz OUT 8 dBm Masking Attenuator DUT APPLICATIONS Attenuation Measurements 0 01 18 GHz extendible to 40 GHz The figure above depicts 8850 18 This system is setup for performing component measurements across the 0 01 18 GHz frequency band without changing any connections on the Model 8850 front panel This setup gives the user the widest measuring frequency range possible Removing the Power Splitter and connectng the input signal directly to t
45. kQ 10 kQ 100 kQ 1 MQ 10 MQ Accuracy See table to the right Calibration Conditions 23 C low power four terminal measurement Temperature Coefficient See Table Power Coefficient See Table Terminal Resistance Units with 1Q or higher resistance Binding posts add 0 1 to 0 2 mQ to four terminal resis tance value banana plugs add 2 to 3 mQ addi tional resistance Accuracy Coefficients Maximum Ratings Long Cali Value Initial Term bration Temp Power Power Current Voltage 2 ppm ppm ppm ppm C ppm mW mW mA 0 01 200 500 50 60 20 60 2500 0 1 100 300 30 40 25 250 1600 1 20 50 10 15 0 3 1000 1000 10 20 50 10 15 0 3 1000 320 100 20 50 10 5 0 1 1000 100 1k 20 50 10 5 0 1 1000 32 10 k 20 50 10 5 0 1 1000 10 100 k 20 50 10 5 0 1 1000 3 2 1M 50 100 20 5 0 1 100 0 3 300 10M 50 100 20 5 0 1 10 0 03 300 Maximum Ratings See Table Breakdown Voltage 1500 V peak to case Calibration Data Initial calibration readings are affixed to instrument Dimensions Height 2 1 5 3 cm Width 3 8 9 65 cm Depth 2 4 6 1 cm Weight 8 oz 227 gm net Standard Equipment 8234 Instruction Sheet GRD 1 2 Initial Accuracy The specifications stated in the TEGAM instrument catalogs and data sheets are intended as acceptance specifications and are guaranteed for 60 days from the date of shipment They are typically maintained for a much longer period of time Long
46. minimum Voltmeter and green LED Temperature Range Operating 10 to 40 C 450 to 104 F Storage 40 to 75 C 40 to 167 F Connectors 2 x 4 pin microphone audio connector Power Requirements 105 125 or 210 250 Vac 47 to 420 Hz 12 Watts factory optional Weight Net 6 Ibs 2 72 kg Physical Dimensions Height 85 61 mm 3 37 in Width 250 00 mm 9 84 in Depth 260 00 mm 10 24 in Rack Mounting The Model 1820 can be shelf mounted in any cabinet or rack designed according to EIA RS 310 and MIL STD 189 This data sheet was current when it was produced However products are constantly being updated and improved Because of this some differences may occur between the descriptions herein and the current product Prices and specifications may be changed without notice Uem YOUR GLOBAL SOURCE FOR TEST AND MEASUREMENT SOLUTIONS TEN TEGAM WAY GENEVA OHIO 44041 440 466 6100 FAX 440 466 6110 www tegam com e mail sales tegam com SYSIIA SURECAL Previews of graphical hook up instructions Easier manipulation of data files Easier setup of flexible standards Display of WORD documents e Faster selection of calibration procedures Sensor procedures can be easily customized SureCAL was calibration engineers and technicians developed by who are determined to cut the high cost of maintaining your equipment SureCAL is the complete TEGAM solution for all your au
47. more guesswork no more damage to motors machinery switchgear or accessories TEGAM indicators have both an ABC lamp and a BAC lamp Just connect the Red White Blue test leads to the three phase circuit When correctly connected the ABC lamp glows A reversed sequence lights the BAC lamp An open phase lights both lamps at 200 volts It s that easy that fast TEGAM s Motor Rotation Indicator prevents costly motor damage by showing rotation direction before connections are made TEGAM s Motor Rotation Indicator MR 1 eliminates guessing and the unsafe damaging practice of bumping to determine which way a three phase motor shaft rotates Just connect the Motor Rotation MOTOR ROTATION Indicator s Red White Blue ABC test INDICATOR clips to the motor and turn the shaft in the PUN TO YEST direction you want it to rotate Push the test button and the ABC or BAC light WE caution ov max Pa comes on showing the correct way to c connect the motor to the power source e Saves time no need to disconnect drive shaft couplings e Eliminates guesswork protects user and equipment e Identifies open windings SPECIFICATIONS AND ORDERING INFORMATION Reliable solid state components Test clips open 1 2 to fit most MODEL T 470 RANGE 115 TO 700V 400Hz mal T 471 115 to 700V 50 60Hz terminals MR 1 9V Maximum Shirt pocket size DIMENSIONS All PSIs 1 25 x 1 50 x 2 Net weight 4 oz One year warran
48. no photo Rack Mount Kit and chassis slide kit for the VM7 1585 1006 Cable N male N male 36 inches DC to 18GHz for connecting the 8852 to a signal source 189 22 CAMLab Software no photo This program provides the technician with automated measurement data collection data dis play and analysis capabilities It saves time by archiving test configurations and test results With this software the 8850 system can perform attenuation measurements from 0 01 to 40 158 1600 Cable GHz The system can also perform SWR and RF Substitution Measurements This data sheet was current when it was produced However products are constantly being updated and improved Because of this some differences may occur between the descriptions herein and the current product Prices and specifications may be changed without notice BACK TO CONTENTS TEGAM TEN TEGAM WAY GENEVA OHIO 44041 B 12 YOUR GLOBAL SOURCE FOR TEST 440 466 6100 FAX 440 466 6110 AND MEASUREMENT SOLUTIONS www tegam com e mail sales tegam com Model SR1 Versatile working standard 50 ppm long term accuracy for most values Select from a wide range of values from 0 0102 to 10MX Accurate stable low cost Prices and specifications subject to change without notice DS amp INSTRUMENTS Standard Resistor The Model SRI Standard Resistor is a laboratory standard of high accuracy and stability The resistance of most values is initially adjus
49. panel TTL SYNC OUT BNC Triggering Characteristics Trigger Input Rear panel TTL TRIG IN BNC Signal 10V max width gt 15ns pos transition Sources Manual internal external or bus Modes Continuous triggered gated burst 1 to 32 767 Frequency External to 10MHz internal from 20us to 999s Internal Synthesizer Resolution 4 digits Accuracy 0 01 of reading Stability 100PPM Functions Sine 10 kHz to SOMHz Distortion 0 196 below 100kHz Harmonics lt 30 dB below carrier 1OOkHz to SOMHz Flatness 1 to IMHz 5 to 1OMHz 15 to SOMHz Triangle 10 Hz to 1OMHz adjustable phase Square 10 Hz to SOMHZz adjustable duty cycle Pulse 10 wHz to 1MHz adjustable parameters Ramp 10 wHz to IMHZ adjustable rise fall times sinc Sin x x 10 Hz to IMHZ 4 to 999 cycles Gaussian Pulse 10 Hz to IMHZ 1000 to 65 535 time constant Exponential 10 Hz to IMHZz 0 01 to 20 time constant DC 1 to 100 of amplitude Arbitrary Waveforms Memory 64k points Wave Segments 1 to 99 Vertical Resolution 12 bits 4 096 points TEGAM YOUR GLOBAL SOURCE FOR TEST Sampling Clock Source Internal synthesizer internal reference external clock Range 10mHz to 100M Hz Resolution 4 digits Accuracy 0 01 of reading Stability 100PPM Built in Utilities Clear Fill Offset Invert AM Sequenced Waveforms Operation Loop and Link Sequences 1to9 Steps to 99 steps Repetitions 0
50. photo 1583 3 1 meter GPIB bus cable 1583 6 2 meter GPIB bus cable 1583 9 3 meter GPIB bus cable 8000 RF Mount Transport Case Three 1583 3 included with all System IA Power Sensor Packages 1585 Series RF Cables 1585 1000 SMA male SMA male 36 inches DC to 18GHz 1585 1006 N male N male 36 inches DC to 18GHz 1585 1008 3 5mm male 3 5mm male 36 inches DC to 26 5GHz 1585 1009 2 92mm male 2 29mm male 36 inches DC to 40GHz 138 477 or CBL F1125 48 Temperature Control Cable no photo Cable is used to connect the heater circuits of the 1805B 1806 to a Thermistor Mount Included with 1805B and 1806 1585 Series RF Cables 138 645 Accessory Kit System IIA kit designed to aid the operator in the calibration of most any type of power sensor and or meter The kit includes 30dB Type N Fixed Attenuator 30dB 3 5mm Fixed Attenuator 2 Type N Male to SMA Female Adapters GPC 7 to Type N Male Adapter Type N Male to SMA Female Adapter S parameter data is supplied on diskette and it all comes in a wooden storage case Included with all System HA Power Sensor Packages A2LA Accredited Calibrations are optional 138 606 Rack Mount Kit no photo Rack Mount Kit for the model 1806 ears only oe P 1919 Rack Mount Kit no photo 138 654 Accessory Kit This kit allows the 1805B Power Level Controller and the 1807A F1119C or FI117AC mounts to be installed in a 19 inch rack Each unit may b
51. plus dual input and easy to use rotary switches These thermometers are the only handhelds whose 1 mV per C analog output can be directly linked to recorders and computers Wide application accuracy 0 25 of reading Dual thermocouple inputs e One hand operation Upper rotary switch selects F or C and 1 or 0 1 resolution lower rotary switch enables fast comparisons of two temperature points Big bright 3 digit LCD display with low battery and open probe indicators e 871A accepts type K thermocouples 872A accepts type J Rugged ABS plastic case ORDERING INFORMATION Two year warranty MODEL TCTYPES INPUTS 871A K Two 872A J Two SPECIFICATIONS ACCESSORIES SUPPLIED 8712 8722 probe 9V battery manual ACCURACY 0 25 of reading 1 C RESOLUTION 0 1 to 200 Full Range REPEATABILITY 0 2 C THERMOCOUPLES RANGE TYPE K TYPE J oF 40 to 1999 40 to 1400 C 40 to 1370 40 to 760 DISPLAY 31 digit LCD 0 6 high DIMENSIONS 7 0 x 3 1 x 1 6 Net weight 10 6 oz ACCESSORIES AVAILABLE 8668 vinyl carrying case This data sheet was current when it was produced However products are constantly being updated and improved Because of this some differences may occur between the descriptions herein and the current product Prices and specifications may be changed without notice TEGAM YOUR GLOBAL SOURCE FOR TEST BACK TO CONTENTS AND MEASUREMENT SOLUTIONS ermocouple Probes
52. poured HI 90A 6c cee wont s cXewee EE RS MOO nuussesue anis Gece dae eet HVB22 pide ieabane see echas anas RV722 inse eeu PR RR rad VEN d ad 9 SB103 Shorting Bars for SR1010 SR1030 amp SR 1060 cis wu eee ree C 23 SC1000 SG5 d se cb5ed e ORLEANS cased G5010 Oscillator SG5030 Sine Wave Generator SG5050 Sine Wave Generator S15010 Scanner SPC102 Series Parallel Compensation Network for SR1010 1030 1050 C 23 SR1 0 01 01 ohm Standard Resistor scc ok x EE ex x ER C 1 SR1 0 1 1 ohm Standard Resistor C 1 SR1 1 1 ohm Standard Resistor C 1 SR1 10 10 ohm Standard Resistor C 1 SR1 100 100 ohm Standard Resistor xv sence cecdeaecesae ded C 1 SR1 1K 1K ohm Standard Resistor C 1 SR1 10K 10K ohm Standard Resistor C 1 SR1 100K 100 K ohm Standard Resistor 000 eee eee eee C 1 SR1 1M 1 M ohm Standard Resistor C 1 SR1 10M 10 M ohm Standard Resistor C 1 SR102 100 ohm Resistance Standard 2 lt 60244 fed cu xd C 3 SR102 DC 100 ohm Resistance Standard with No Case for Oil Bath Immersion een C 4 SR104 10 K Resistance Standard 0 1 PPM T C C 3 SR104 DC C 4 SR1010 1 1 ohm Resistance Transfer Standard C 5 SR1010 10 10 ohm Re
53. sequence generator Each sequence program can have up to 100 steps which can link to any of the 2711A s 100 user defined waveforms Each waveform may be looped over one million times per step Ten unique sequence programs may be stored in the sequencer s non volatile memory WaveWorks M Jr is a complete software solution for importing exporting creating and editing waveform data in the common ASCII formats CSV and PRN Windows M compatible it allows full programming access to both the instrument and the sequence generator WaveWorks Pro IM advanced wave creation software is available as an upgrade See the WaveWorks Pro data sheet for more details Warranty The Model 27114 is backed by a full 3 year warranty and TEGAM s 30 day no risk trial YOUR GLOBAL SOURCE FOR TEST AND MEASUREMENT SOLUTIONS E 8 Model 2711A LOW COST 16 BIT AWG Specifications Output Waveforms Up to 100 High definition custom waveforms Sine Square Triangle Ramp DC Exponential Haversine Pulse Gaussian Sin x x Sinc Waveform Storage Resolution sample Rate Transition Time 100 Waveforms Horizontal Points 65 500 max Vertical Points 16 bits 65 536 32 767 to 32 768 0 1Hz to 2MHz 10s to 500ns 4 digit resolution 50ppm accuracy lt 150ns Tested with square wave filter off 10Vp p 50 2 termination Spectral Purity THD Noise 86 dB typical Tested with 8
54. the selected frequency These simple calculations can be performed by the user or by entering the readings into the Microsoft Excel spreadsheet provided by TEGAM This spreadsheet contains the formulas necessary to calculate cal factor and is provided as a convenience for our customers YOUR GLOBAL SOURCE FOR TEST AND MEASUREMENT SOLUTIONS Colo Bi E YAA WIDEBAND POWER SENSOR CALIBRATOR Specifications Frequency Range 100 kHz to 18 GHz Power Range 0 01 to 25 mW 20 to 14 dBm Substitution Bridge Accuracy 0 003 Nominal RF Impedance 50 Ohms VSWR lt 1 14 Power Linearity 0 1926 from 1 to 10 mW Insertion Loss RF INPUT 6 dB nominal 10 dB max Individual calibrations traceable to NIST supplied at the following frequencies 100 200 455 kHz 1 1 25 3 5 MHz 10 to 100 MHz in 10 MHz steps 100 MHz to 2 GHz in 50 MHz steps 2 GHz to 4 GHz in 100 MHz steps 4 to 12 4 GHz in 200 MHz steps 12 75 to 18 GHz in 250 MHz steps Calibration Factor Accuracy 0 80 from 0 1 to 10 MHz 1 00 from 0 01 to 10 GHz 1 10 from 10 to 18 GHz Calibration Factor Drift 0 5946 per year Connectors SENSOR N type Female RF IN SMA Female X2 VOLTMETER Binding Post standard 0 75 spacing for banana plugs Temperature Operating 12 to 32 C 454 to 90 F Storage 40 to 75 C 40 to 167 F Warm up time 2 hours Power Requirements 12 W
55. to 32 767 loops 99 wave segments Sampling Clock Source Internal synthesizer internal reference external clock Internal Synthesizer Range 10mHz to 100MHz Resolution 4 digits Accuracy 0 01 of reading Stability 100PPM Environmental Operating Temperature 32 F to 104 F 0 C to 40 C ambient Specified Accuracy 68 F to 86 F 20 to 30 C Storage Temperature 40 F to 86 F 40 to 60 C Humidity Range 80 R H non condencing Stored Settings Setups 10 instrument settings GPIB Interface IEEE 488 2 1987 SCPI 1993 All front panel controls are accessible via GPIB interface except the power switch Subsets SHI AHI T6 TEO L4 LEO SR1 RLI PP2 DC1 DTI CO General Display 2 line 16 characters back lit LCD Power 115 230 Vac 50 60 Hz 60 VA max Dimensions 8 3 x 3 5 x 15 4 21 1 X 8 89 X 39 1 cm Wx Hx D Weight Approximately 9 lbs 4 1 kg This data sheet was current when it was produced However products are constantly being updated and improved Because of this some differences may occur between the descriptions herein and the current product Prices and specifications may be changed without notice BACK TO CONTENTS TEN TEGAM WAY GENEVA OHIO 44041 440 466 6100 FAX 440 466 6110 www tegam com e mail sales tegam com AND MEASUREMENT SOLUTIONS Model 2711A e Waveform Creation Software Included e 10 Standard Waveforms 64k Waveform Memory e Stores 100 Custom Wa
56. to simplify the settings The switch settings are easily read from the large numeral in line presentation above the knobs Switching transients are virtually eliminated due to a special circuit which couples the adjacent voltage steps through a resistor while the switching is taking place The range overlap between decades is 10 permitting accurate voltage ratios from 1 1 to 0 1 The high input impedance of the DT72A makes it well suited for use in high impedance circuits without causing excessive loading Model DT72 TEGAM H YOUR GLOBAL SOURCE FOR TEST AND MEASUREMENT SOLUTIONS C 17 C 18 Model DT72A DECADE RATIO TRANSFORMER STANDARD Specifications Characteristic DT72A Specifications Frequency Range 50 to 20 000 Hz Maximum rms Input Voltage 0 35f f in Hz or 350 volts whichever is less Ratio Range Maximum Minimum 1 111111 0 0111111 Maximum Phase Shift Approx 0 05 mrad kHz for settings above 0 1 Resolution 0 00001 0 1 ppm Maximum Input Current For best performance no DC current should be permitted DC input of 20 uA will decrease AC input voltagerating about 10 and increase distortion slightly 200 uA will cause near saturation of core and serious errors Terminal Linearity 50 Hz to 1 kHz 0 9 ppm referenced to input for settings 0 1 to 1 0 0 9 10 X setting 0 01 ppm for settings 0 to 0 1 Above 1 kHz multiply by f in kHz B
57. when it was produced However products are constantly being updated and improved Because of this some differences may occur between the descriptions herein and the current product Prices and specifications may be changed without notice BACK TO CONTENTS TEGAM YOUR GLOBAL SOURCE FOR TEST AND MEASUREMENT SOLUTIONS Voltmeter Accessories ELECTRICAL SAFETY METERS Leather Utility Belt Carrying Case ORDERING INFORMATION The 1104 case protects your volt meter and probes from broken displays and other damages that can occur This case has a 2 belt loop It is long lasting super durable and is made from top grain cowhide with riveted seams MODEL 1104 Cordura Nylon lineman s Carrying Case The 1204 case protects your volt meter and saves you time because the meter can stay in the case during use The 1204 features a window to access the ON OFF switch a retainer that holds the meter in place space for probe storage and a 22 shoulder strap Designed specifically for linemen the strap can be hung on a nail or unsnapped and put around a pipe or pole freeing both hands to take measurements When you have to go out at night or your meter gets mis placed the bright yellow cordura nylon case 1s easy to see The 1204 case also comes with a belt clip and can be worn on a utility belt Overall size is 5 Wx Hh Hxl 2 D ORDERING INFORMATION EEOSE AE ORDERING INFORMATION The 12501 probe adapter kit a
58. 0 01 to 10 mW 20 to 10 dBm Interface WR 28 Waveguide Flange WR 28 Waveguide Flange Max VSWR 1 20 from 26 5 to 40 GHz 1 20 from 26 5 to 40 GHz Power Linearity 0 1920 from 1 to 10 mW lt 0 1 from 1 to 10 mW Insertion Loss 3 dB max 6 dB max Individual calibrations traceable to NIST supplied at the following frequencies 26 5 GHz 27 to 40 GHz in 1 GHz steps 26 5 GHz 27 to 40 GHz in 1 GHz steps Calibration Factor Accuracy 1 75 from 26 5 to 40 GHz 2 1 from 26 5 to 40 GHz Calibration Factor Drift 0 596 per year 0 596 per year Thermistor DC Bias Power 13 2 mW 13 2 mW Thermistor Resistance at Bias 200 Ohms 200 Ohms Temperature Operating Storage 12 to 40 C 454 to 104 F 55 to 75 C 67 to 167 F 12 to 40 C 54 to 104 F 55 to 75 C 67 to 167 F Warm up time 2 hours 2 hours Weight 5 82 Ibs 2 64 kg 5 86 lbs 2 66 kg Physical Dimensions Height Width Depth 11 2 in 285 mm 9 4 in 239 mm 12 4 in 315 mm 11 2 in 285 mm 9 4 in 239 mm 15 4 in 391 mm This data sheet was current when it was produced However products are constantly being updated and improved Because of this some differences may occur between the descriptions herein and the current product Prices and specifications may be changed without notice A 14 TEAM Y YOUR GLOBAL SOURCE
59. 0 bin capability makes the 3550 very attractive for binning applica tions The user can select either Absolute or Percentage comparator operation and can enable an audible pass fail buzzer Changeovers are easy because nine different instrument setups may be stored and recalled from instrument memory and a front panel lock feature prevents accidental changes of instrument settings RS 232C and I O connector TTL interfaces for han dlers or sequencers are standard a GPIB interface is optional A wide variety of accessories are available to accommodate various test applications These include Kelvin Klips Tweezers for Surface Mount Components Surface Mount Test Fixtures Radial Axial Adapters and more Programming information and connection instructions are included to simplify integration Fast Accurate and Versatile at a Very Reasonable Price The 3550 increases production line effi ciency because it produces an LCR reading in as little as 18mS It can measure 16 para meters and produce a reading and a useable comparator output in as little as 40mS You would expect to pay much more for an LCR meter with this speed and versatility This unit handles traditional component test materials characterization incoming inspection plus high frequency profil ing applications too The 3550 is built with the quality and reliability of all TEGAM products and is backed with a full 1 year warranty YOUR GLOBAL SOURCE FOR TEST AND MEASU
60. 08 jd 0 008 SureC AL default profiles cannot be permanently deleted or updated but you may create custom profiles from them or modify them for temporary use Upon receipt of the software you can download onto your workstations and start saving time immediately And here are some samples of time savings from SureCAL when combined with TEGAM instruments system IIA Power Sensor Calibration System Manual SureCAL Test Equipment Test Test SAVINGS minutes minutes minutes TEGAM 1807A 471 63 408 TEGAM F1119 371 52 319 TEGAM F1116 371 52 319 TEGAM F1117A 471 63 408 TEGAM YOUR GLOBAL SOURCE FOR TEST AND MEASUREMENT SOLUTIONS BACK TO CONTENTS A 23 SYSIIA SURECAL AUTOMATED CALIBRATION SOFTWARE Customers with the most demanding test requirements can now tailor their own calibration profiles using our new flexible POWER SENSOR RESPONSE TEST PROFILES PE ureCal C PROGRAM FILES HTBWINS3 ACT SURE_12Z3 s l Pij pm Test Profile Current Profile Name Type Status WP 858168 Standard Cal 21 points Default Loaded UUT Monitor STD Monitor DataFormat p General UUT Sensor STD Sensor Source Amp Test Points Profile Options _Setect Nominal TestLevel 0 008 dBm R Reference Frequency 50 000 MHz 10
61. 0kHz measurement bandwidth 2MHz clock 2 kHz sine wave 1000 points filter on full amplitude 50Q termination Amplitude and Offset Range 1 00 to 10V 100mV to 999mV 10mV to 99 9mV Resolution Accuracy 10mV 1 of setting 20mV ImV 3 of setting 5mV 100u V 5 of setting ImV Note 50Q source impedance measured at open circuit tested with kHz sinewave plus DC offset Analog Filter User selectable 700kHz 7th order 40kHz 3rd order Sequence Generator Optional Waveform Transient free Loop and Link Repetitions Loop 1 048 575 times Link 100 waveforms Program 100 Steps total File 10 Sequences Operational Modes Continuous Output runs continously between selected memory address locations Triggered Output at start point until triggered then runs once Gated As triggered except output is continous until gate signal ends Burst Each trigger outputs a preprogrammed number of waveforms from 1 to 1 048 575 Toggled Alternate triggers gate the output waveform Master Slave For multi unit operation Cont Sync Multiple units run continuously in sync with the master unit Trig Sync Multiple units run in sync with the master unit for one cycle when the master unit is triggered Trig Seq Atail chasing mode between the master and the slave unit initiated by triggering the master unit This data sheet was current when it was produced However products are constantly being updated and
62. 1116 102 373 5 Power Splitter for F1119 102 475 1 Power Splitter for F1109 110A Safety Voltmeter H 1 120 Voltman Electrical Service Voltmeter iesus kk Rx Rex H 1 122 Voltman Electrical Service Voltmeter with Continuity H 1 125 Voltman TRMS Electrical Service Voltmeter with Continuity Function eure mtr Pat S out Re H 1 138 606 Rack Mounting Kit for i20 Am A 27 138 645 Measurement Accessory Kit for System IIA A 27 138 645 1 9 138 645 2 29 sy 9 138 645 4 9 138 645 5 9 138 650 Calibrated 50 75 Ohm Minimum Loss Matching Pad for System IIA 138 652 arva Roc e Rogo A 27 187 1007 Rack Mount Kit for VM 7 B 12 187 1007 1 Rack Mount Kit for DEOS Les ruis dE RUE RU e Mes B 12 187 1008 Rack Mount and Chassis Slide Kit for VM 7 B 12 187 1009 I O Card Upgrade Kit for VM 7 lens B 12 187 1020 000 Digital Extender Card for VM 7 005 B 12 187 1021 000 Analog Extender Card for VM 7 00055 B 12 187 1030 Spare Set of All Replaceable Modules for VM 7 B 2 187 1800 2 Display Upgrade Kit S N 0 to 102 for VM 7 B 1 187 4001 Attenuation Measurement Accessory Kit for 8850 B 12 187 4003 SWR Measurement Accessory Kit for 8850 B 12 189 22 CAMLAB Attenuation Measurement Software
63. 145 is for panel mounting and has three decades plus an interpolation potentiometer It features stacked dials which results in a configuration that requires less than 7 square inches of panel space BACK TO CONTENTS YOUR GLOBAL SOURCE FOR TEST AND MEASUREMENT SOLUTIONS Model DT1145 DEKATRAN DECADE RATIO TRANSFORMERS Characteristic DT1145 Specifications Frequency 50Hz to 5kHz Terminal Linearity Initial amp Long Term 50 Hz to 1 kHz 10 ppm referenced to input Above 1 kHz multiply by 1 0 1f in kHz All setting combinations producing the same nominal output voltage remain with the stated linearity specifications Number of Decades Three plus interpolating potentiometer Resolution Continuous 0 001 per dial division Maximum Ratio 1 11100 Maximum Phase Shift Approximately 0 05mrad kHz for settings above 0 1 Maximum Input Voltage 0 33 VRMS Hz 350V maximum Maximum Input Current DC 10 uA Input Impedance High with no output load Typical range of measured values for various dial settings and voltages shown in curves Input Inductance Approximately 100 to 300H depending on excitation Output Current 1A maximum Output Impedance Approximately 2 5 2 maximum in series with 100 yH Harmonic Distortion 0 0008 x fkHz of output voltage peak to peak for input voltage less than 0 35 x f 011 VRMS D
64. 2LA Accredited calibrations Prices and specifications subject to change without notice Transfer Standards TEGAM Temperature Stabilized Coaxial RF Power Transfer Standards enable the precise measurement of microwave power in the 10 MHz to 26 5 GHz frequency range With this wider frequency range the F1135 and M1135 can be used in applications that previously required two standards These units are extremely rugged highly accurate and stable with time and temperature They are ideal for use as standards for the transfer of calibration factors to other RF standards and power sensors Units are supplied with ANSI NCSL Z540 1 1994 NIST trace able calibration data A2LA Accredited Calibrations are optional These models are designed for use with dc self balancing bridges such as the TEGAM Model 1806 and 1804 or with controllers such as the TEGAM Model 1805B FREQUENCY RANGE 10 Miir to 26 5 Ge POWER RANGE 10 pW to 25 mw BACK TO CONTENTS System configurations employing instruments of this extreme accuracy typically achieve calibration factor transfer results normally found only in primary standards laboratories The Model F1135 is a feedthrough Thermistor Standard and Power Splitter combination used for the calibration of bolometer thermocouple and diode terminating power sensors Its expanded frequency range has been achieved without compromising the accuracy specifications after VSWR correction The Model M1135
65. 50 traceability right on the product floor and in less time BACK TO CONTENTS than it takes to reload a resistor reel It s Ready for Any Job The 1750 provides the speed and accuracy desired for automated produc tion test requirements as well as bench top quality control and inspection appli cations Not only is the 1750 perfect for high speed production test of low resis tance electronic components but the low current capability and TRUE SPEED performance make the 1750 excellent for dry circuit testing of switches relays and connector contacts without disturbing the device s contact surfaces 1750 fits most resistor wire fuse thermistor and trim mer testing applications For more information contact TEGAM at 800 666 1010 TEGAM YOUR GLOBAL SOURCE FOR TEST AND MEASUREMENT SOLUTIONS G 1 Model 1750 HIGH SPEED MICRO OHMMETER TABLE 1 Full Scale Voltage and Maximum Lead Resistance as a Function of Reference Current RANGE RESOLUTION REFERENCE CURRENT AVAILABLE SELECTION mn my xa 200 mV MAX LEAD RESISTANCE 500 mQ TABLE 2 o o LL LLL cw ow omv xmv L xomv 3mv zv om omw L lv om 1 Th A l1 L 30 50 Q 100 Q 100 Q TABLE 3 100 Q 100 Q 100 Q Delayed Mode Accuracy In terms of FULL SCALE VOLTAGE Temperature Coefficients In terms of FULL SCALE VOLTAGE ACCURACY FULL SCALE VOLTAGE 18 2
66. 6 6110 AND MEASUREMENT SOLUTIONS www tegam com e mail sales tegam com RTD Probes DIGITAL THERMOMETERS AND PROBES General Purpose Immersion Probe For measuring gases liquids soft materials or small area surfaces 316 SS sheath TPR coil cord 1 ft ext 5 ft Range 200 C to 600 C Time constant 10 sec Accuracy 0 3 C 0 5 ORDERING INFORMATION MODEL 8693 Surface Probe For measurements on hot or cold flat surfaces 304 SS sheath TPR coil cord 1 ft ext 5 ft Range 50 C to 260 C Time constant 3 sec Accuracy 0 3 C 0 5 ORDERING INFORMATION MODEL 8695 c 6 Air Gas Probe For measuring air and other gaseous atmospheres 304 sheath TPR coil cord 11 5 ft ext 5 ft Range 50 C to 260 C Time constant 5 sec Accuracy 0 3 C 0 5 ORDERING INFORMATION F BR 4 NOTE All TEGAM 100Q Platinum RTD probes have Ls 4 4 wire RTDs and are supplied with a Switchcraft TA4FL or equivalent compatible connector Pin 2 sense 868 9 This data sheet was current when it was produced However products are constantly being updated and improved Because of this some differences may occur between the descriptions herein and the current product Prices and specifications may be changed without notice IEGAM YOUR GLOBAL SOURCE FOR TEST AND MEASUREMENT SOLUTIONS Probes and Thermo RS AND PROBES Tilt Stand P
67. 8 C 1 yr 0 02 RDG 5 COUNTS 0 02 RDG 4 COUNTS 0 02 RDG 2 COUNTS 2mV 20 mV 200 mV 2 mV 20 mV 200 mV 2V 0 02 RDG 2 COUNTS 2V 2V 2 MQ amp 20 MQ ranges 0 04 RDG 2 COUNTS FAST MODE ACCURACY is 0 05 5 COUNTS Reference Current Modes Fast Continuous Pulsing reference current REF 0 with automatic thermal and noise rejection Fast One Shot Triggered single cycle of Fast Continuous Mode Delayed Continuous Alternating reference current REF REF with programmable settling time for reference current and line cycle digitization Delayed One Shot Triggered single cycle of Delayed Continuous Mode G 2 FULL SCALE VOLTAGE 2 V 2 MQ amp 20 MQ RANGES 0 18 C and 28 50 C 0 004 RDG 1 COUNT 0 004 RDG 0 5 COUNTS 0 002 RDG 0 1 COUNTS 0 002 RDG 0 1 COUNTS 0 008 RDG 0 5 COUNTS uNE CYCLE DELAY BACK TO CONTENTS Model 1750 HIGH SPEED MICRO OHMMETER TABLE 4 Measurement Times FAST MODE FULLSCALE VOLTAGE DELAYED MODE v FULL SCALE VOLTAGE RANGE 2mv 20mv 200mv 2v 2mv zmv mmv 2v 3 1 hl In ll hh d ol ll hl ln rpoh oma hl Il gt 38 hl ll nroh w9 hl iP gt lo oo one p gt D gt ze ome jme gt gt C hh ol 1L 3a 1 HI L rn om 1 LL hh rn ol 1 ll TH T rr rn TABLE 5 Reading Rat
68. 88 0086 Qi8088 000 1000 00a le p 8 008 0 089 y 8 888 8 888 8 08 r 0 000 0 000 0 DF z 6 600 0 000 a 0 000 6 000 8 t NOTE default profiles be rie i or updated but you Return to Test Eite Eis view DE Nit Help SureCAL Test Manager provides e Tool bars for fast access e Permanent data archiving e Exporting of calibration results e Streamlined user displays Graphical hook up instructions e Easier manipulation of data files e Easier setup of flexible standards e Capability to launch Word Excel Sa CLD DE TYSSE E Access and other utilities EES oe A AR NRO Ca EE t e Faster selection of calibration procedures SELF TEST FREQ RESOLUTION LF HAX LEUELED PUR LF POWER ACCURACY HAX LEVELED POWER ACCURACY amp FLATHESS HARMONIC SPURS H H HRRH HIC SPURS SSB PHASE HOISE PULSE HOD OM OFF IHTERHAL AM RATE IHTERHAL FM SOURCE Has ACFM DEVIATION FH FLATHESS 36 GHZ Plus a host of other improvements to simplify its use and improve your productivity This data sheet was current when it was produced However products are constantly being updated and improved Because of this some differences may occur between the descriptions herein and the current product Prices and specifications may be changed without notice BACK TO CONTENTS TEGAM TEN TEGAM WAY GENEVA OHIO 44041 A 24 YOUR GLOBAL SOURCE FOR TEST 440 466 6100 FAX 440 466 6110 AND MEASUREMENT SOLUTIONS www te
69. A 10 Dimensions 7 88 X 3 94 X 6 70 20 X 10 X 17 cm WXHXD Weight 5 5 b 2 5 kg Approximate Weight Standard Unit Included Accessories Operation Manual PN 3525 900 01CD Kelvin Klips PN 47454 Grounded Power Cord PN 161006600 Options Radial Lead Adapter PN 3510 Chip Tweezers PN 2005B Chip Test Fixture PN 3511 BCD Interface PN 3502 GPIB IEEE 488 Interface PN 3501 This data sheet was current when it was produced However products are constantly being updated and improved Because of this some differences may occur between the descriptions herein and the current product Prices and specifications may be changed without notice YOUR GLOBAL SOURCE FOR TEST AND MEASUREMENT SOLUTIONS BACK TO CONTENTS TEN TEGAM WAY GENEVA OHIO 44041 440 466 6100 FAX 440 466 6110 www tegam com e mail sales tegam com Model 3550 e 16 Measurable Parameters Absolute or Percentage Comparator Binning Function Supports 10 Output Bins Three Highly Visible LED Displays e Standard RS 232C amp 1 0 Interfaces Optional GPIB or BCD Interfaces 1 Year Warranty ENT INSTRUMENTS 42 0 Hz 5 00 MHz Programmable LCR Meter The Model 3550 is a fully programma ble 42 0 Hz to 5 00 MHz LCR Meter It is designed for a wide variety of automated or manual testing applications from traditional LCR measurements to frequency character ization of LCR components and materials All settings are in
70. BIAS VOLTAGE primary standards laboratories The Model F1125 is a feedthrough Thermistor Standard and Power Splitter combination used for the calibration of bolometer thermocouple and diode terminating power sensors The Model M1120 is a terminating thermistor Primary Transfer Standard It is designed to be calibrated directly by a national standards agency such as NIST The M1120 is used for the calibration of feedthrough devices such as bolometer mount coupler and bolometer mount splitter RF Standards It is also useful in other applications requiring direct measurement of RF power Both Models feature a Type N RF connector Bias connectors are binding posts with standard 0 75 spacing for banana plugs The internal heater is connected using cables provided with the Models F1125 1805B 1806 and 1820 Prices and specifications subject to change without notice BACK TO CONTENTS YOUR GLOBAL SOURCE FOR TEST AND MEASUREMENT SOLUTIONS Model F1125 M1120 COAXIAL RF POWER TRANSFER STANDARDS Specifications Frequency Range F1125 100 kHz to 4 2 GHz M1120 100 KHz to 4 2 GHz Power Range 0 01 to 25 mW 20 to 14 dBm 0 01 to 25 mW 20 to 14 dBm Nominal Impedance 50 Ohms 50 Ohms Max VSWR 1 06 from 100 kHz to 4 2 GHz 1 40 from 100 to 500 KHz 1 20 from 0 5 to 1 MHz 1 10 from 1 to 1000 MHz 1 20 from 1 to 4 2 GHz Power Linearity 0 190 from 1 to 10 mW lt 0 1 f
71. C RE SB103 PC101 and MO Buts SPC102 as necessary 1089 l p 10 1 1 ppm 0 1 uQ at 100 Q to 100 kQ 5 ppm C matched within 3 ppm C series or parallel value using SB103 PC101 Power Coefficient typical and SPC102 as necessary 1Q 0 3 ppm mW resistor Initial Adjustment 10 Q 0 02 ppm mW resistor 20 ppm of nominal value matched within pea DOS E DPIDAGMYUSESISEOE 10 ppm Maximum Power Rating Calibration Accuracy Single Step IW step 10 resistors 5W distributed 10 ppm NIST traceable Leakage Resistance 1 Q to 10 KQ gt 10 Q terminal to case 100 KQ gt 10 Q terminal to case Calibration Conditions 23 1 C low power four terminal measurement initial calibration readings are provided Maximum Current and Voltage Capabilities SR1030 Resistance Value Per Step 10 Resistors in Series R10 10 Resistors in Parallel R 10 One Resistor Alone Maximum I V Maximum I V Based on the breakdown voltage of 1500 volts peak to case Maximum I V 707 mA 7 07 V 223 mA 22 3 V 70 7 mA 70 7 V 22 3 mA 233 V 7 07 mA 707 V Combined Option Functional Specifications Ten Resistors Nine Resistors Ten Resistors Resistor Grouping in Parallel in Series Parallel Individual Resistor Value R Resistance Added to Value Calculated from Individual Four Terminal Measurement Resistor Values Value and Tolerance in Microhms With SB103 and PC101 Bomae TE or SPC102 E Two Terminal Measurement
72. FOR TEST AND MEASUHEMENT SOLUTIONS BACK TO CONTENTS TEN TEGAM WAY GENEVA OHIO 44041 440 466 6100 FAX 440 466 6110 www tegam com e mail sales tegam com Model 1805B Internal temperature controlle e DC substitution amp bias supply Automatic DC level control Front panel mount error indicator One year warranty Optional A2LA Accredited Calibrations Other features of the 1805B are Automatic DC Level Control To within 0 1 luW with a RF source variation of 3 dB and an ambient temperature range of 12 to 40 C The dc substitution level is held to an accuracy of 0 1 5uW e DC Substitution and Bias Supply Maximum accuracy is achieved by using DC power for both bias and substitution signals Quick Visual Indication of Operation and Performance The unit employs LEDs to inform the user of RF power on off condition ac power on standby mount error and remote listen functions Easy to read meters are used to monitor temperature stability and bridge balance Prices and specifications subject to change without notice MEASUREMENT PRODUCTS RF Power Level Control Unit 0 5 to 10 mW The 1805B RF Level Control Unit provides fast reliable and accurate leveled RF power when used in a closed loop feedback arrangement The unit provides automatic dc substitution at 0 5 mW and 1 mW to 10 mW in 1 mW steps using local or IEEE 488 bus control for easy and accurate transfer of calibr
73. GAM XXXX is the model number of the instrument warranted This program offers three full years of Calibration services starting from the date of shipment CA5 XXXX X XXX is the model number of the instrument warranted This program offers five full years of Calibration services starting from the date of shipment This data sheet was current when it was produced However products are constantly being updated and improved Because of this some differences may occur between the descriptions herein and the current product Prices and specifications may be changed without notice BACK TO CONTENTS TEN TEGAM WAY GENEVA OHIO 44041 440 466 6100 FAX 440 466 6110 www tegam com e mail sales tegam com TEGAM Vi K 2 YOUR GLOBAL SOURCE FOR TEST AND MEASUREMENT SOLUTIONS program assures that not only will your instrument continue to func tion properly but also that Traceable Calibrations are performed at the TEGAM recommended intervals This program is offered in three year and five year increments Total Service Plan PLAN FEATURES Repair and recalibration by trained factory technicians if your instrument stops working or goes out of calibration prematurely excluding abuse or misuse e This includes Isolation and correction of any faults Repair Replacement of defective components Functionality Verification and a new calibration if required e All Parts and Labor are included at no charge
74. HERTZ This data sheet was current when it was produced However products are constantly being updated and improved Because of this some differences may occur between the descriptions herein and the current product Prices and specifications may be changed without notice BACK TO CONTENTS TEN TEGAM WAY GENEVA OHIO 44041 440 466 6100 FAX 440 466 6110 www tegam com e mail sales tegam com TEGAM YOUR GLOBAL SOURCE FOR TEST AND MEASUREMENT SOLUTIONS Model DT1145 ING SEREREEE reading errors e Exceptionally low output impedance Prices and specifications subject to change without notice ASUREMENT INSTRUMENTS Dekatran Decade Ratio Transformers The Dekatran decade ratio transformers are inductive voltage dividers for use at audio frequencies They feature high input impedance low output impedance and low phase shift and are ideal for use as working standards in test setups and calibration laboratories Applications include voltage and current division turns ratio measurement divider calibration and impedance comparison Initial accuracy and long term stability over a wide range of ambient conditions are assured by the use of gapless toroidal cores of very high permeability Their inherently stable characteristics assure permanent calibration over wide ranges of temperature humidity vibration and shock A sturdy metal case provides both mechanical protection and electrical shielding The Model DT1
75. L SOURCE FOR TEST AND MEASUREMENT SOLUTIONS C 11 C 12 Model DB62 DEKABOX IN LINE DECADE RESISTORS Specifications Model Total Smallest Resistance Values Q No Resistance Step DB62 Q Q R1 R2 R3 R4 R5 R6 11 1111M 10 1M 100K 10K 1K 100 10 1 11111M 1 100K 10K 1K 100 10 1 111 111K 0 1 10K 1K 100 10 1 0 1 11 1111K 0 01 1K 100 10 1 0 1 0 01 Accuracy Accuracy of resistance increments is given in the table below Accuracy of resistance change from zero setting is given below Initial 60 days 0 0196 3 mQ Long term 0 0296 6 mQ year Short Term Switching Repeatability 0 24 mQ typical Number of Decades Six Total Resistance Resistance per Decade Smallest Step See table above See table above See table above Resistance at Zero Setting Approximately 12mQ Breakdown Voltage 1 000 V peak to case OUTER CASE Dimensions Dekabox Schematic Diagram Height 4 3 in 10 9cm Width 18 0 in 45 7cm Depth 4 9 in 12 45 cm Weight 4 5 lb 2 2 kg net Standard Equipment Model DB62 comes with a 7275 instruction manual Calibration amp Technical Services For warranty and remedial repair calibration services and spare parts or for additional information on TEGAM sales and service offices around the world contact us at 440 466 6100 ph or 440 466 6110 fx Model DB62 ratings per step for each decade Resistance Res
76. MHz receiver it may be easily adapted to any frequency range with the addition of an appropriate external mixer and local oscillator FEATURES INCLUDE Advanced Techniques The Model VM 7 uses advanced digital and analog techniques in a series IF substitution configuration offering a dynamic range in excess of 100 dB The unit is also fully bus controllable A combination of switched gain and distributed throughout the receiver An A D is used attenuation stages are in place of the classic piston attenuator to provide the receiver s unique linearity and accuracy The unit is configured as a dual A digitally controlled phase lock loop at the first conversion receiver conversion allows the receiver to deal effectively with less desirable signals as well as clean synthesized signals Final handled digitally allowing the receiver to synchronous detection is achieve resolution down to 0 001 dB Variations in signal to noise ratio are not handled by injection of noise as in previous receivers of this type This is now handled in the post detection signal processing using a noise algorithm Prices and specifications subject to change without notice UREMENT Advanced 30 MHz Receiver Reliability The VM 7 has undergone extensive testing on production units so that customers will be ensured excellent reliability in service Special attention has been paid to cooling requirements significantly extending component
77. MLab to stop before each measurement performed The graph window also contains a vertical toolbar which contains the graph window icons These icons are used to quickly perform such functions as printing the graph changing the printer setup copy page graph to windows clipboard zoom controls copy paste individual plot s and change X Y axis scale of the graph Define Generator Drivers Easily The CAMLab program is capable of automatically controlling the RF generator via the GPIB IEEE 488 interface bus As with other programs generator drivers may not work To combat this problem CAMLab utilizes an alternative approach The RF generator drivers are ASCII text files containing a particular RF with all makes and models generator IEEE 488 commands arranged in a specific format The CAMLab program reads the information from these driver files and builds the IEEE 488 commands necessary to operate the RF generator Customers now have the advantage of creating their own RF generator drivers for the particular generator being used Many Compatible Bus Controllers CAMLab requires a Windows based or compatible computer in addition to a National Instruments GPIB interface Contact TEGAM for further information on requirements or to order a compatible computer system Use Any Windows Compatible Printers CAMLab makes use of the Windows printer functions to select and set up each printer to meet the specific needs of the user Windo
78. Mid scale rating Improves near end scale settings Coefficients of Linearity Temperature 2 ppm C Power 30 ppm W for 1kQ 10 ppm W for 10kQ Calibration Conditions 23 C low input power Number of Decades Two plus 100 division potentiometer Resolution 0 003 Input Resistance 1 10kQ accuracy 0 01 Maximum Input Power 5W continuous 10W intermittent Breakdown Voltage 750V rms to case Dimensions Diameter 3 in 7 6cm Depth 7 2 in 18 3cm Depth behind panel 5 9 in 15cm Weight 1 7 Ibs 772gm net DP 1311 Dekapot Decade Potentiometer Specifications for the DP 1311 are the same as for the DP 1211 except for the following Number of Decades Three plus 100 division potentiometer Dimensions Diameter 3 in 7 6cm Depth 8 5 in 21 6cm Depth behind panel 6 9 in 17 6cm PANEL Weight 2 1 lbs 1kg net MOUNTING 188 DIA GO 4 HOLES 1 876 DIA This data sheet was current when it was produced However products are constantly being updated and improved Because of this some differences may occur between the descriptions herein and the current product Prices and specifications may be changed without notice ry TEN TEGAM WAY GENEVA OHIO 44041 YOUR GLOBAL SOURCE FOR TEST 440 466 6100 FAX 440 466 6110 AND MEASUREMENT SOLUTIONS www tegam com e mail sales tegam com Model DT72A e Bandwidth 50 Hz to 10 kHz e Parallel switches reduce contact resistance e Swit
79. PIB IEEE 488 Cable 3 Meters Long 45 1585 1000 Test Cable with SMA Straight Plug Connectors DC to 18GHz 3 Feet Long 1585 1003 Test Cable with SMA Straight Plug Connectors DC to 18GHz 1 Foot Long i RR 1585 1006 Test Cable with Type N Straight Plug Connectors DC to 18 GHz 3 Feet Long 1585 1008 Low Loss RF Cable with 3 5mm Male Connectors DC to 26 5GHz 3 Feet Long 1585 1009 Low Loss RF Cable with 2 92mm Male Connectors DC to 40 0GHz 3 Ft Long lt 1999 252507445 d hid st Rd cubus ius 9 pri A t 9 1700 1701B 9 1700 1705B 9 1700 SP3779B 9 170 TB coe dh dence ws eee eee ees ae rio 9 1727A Amplifier 1727A 01 Amplifier 1750 Micro Ohmmeter G 1 1750 17501 Micro Ohmmeter with 3 Foot Kelvin Klip Leads G 1 1750 17502 Micro Ohmmeter with 3 Foot Spade Lug Leads G 4 1804 Single Type IV RF Power Me oussitieack hen es eee eee E A 17 180B ccs ED RES REESE PEE 9 1805B RF Power Level Controller A 15 1806 Dual Type IV RF Power Meter eren 1807A F1109 RF Power Standard in an Enclosure 1820 RF Mount Temperature Controller 1825 Economical RF Power Sensor Calibrator 1827 Economical Wideband
80. Post standard 0 75 spacing for Banana plugs Power Requirements 110 120 220 240 Vac 5 10 48 to 62 Hz 25 Watts Weight Net 16 lbs 7 26 kg Physical Dimensioins Height 5 2 in 132 1 mm Width 17 05 in 433 1 mm Depth 18 35 in 466 1 mm Rack Mounting The Model 1806 can be mounted in any cabinet or rack designed according to EIA RS 310 and MIL STD 189 using the Rack Adapter Kit P N 138 606 This data sheet was current when it was produced However products are constantly being updated and improved Because of this some differences may occur between the descriptions herein and the current product Prices and specifications may be changed without notice BACK TO CONTENTS ACCREDITED i E GA M Certificate no 2018 01 TEN TEGAM WAY GENEVA OHIO 44041 A 20 YOUR GLOBAL SOURCE FOR TEST 440 466 6100 FAX 440 466 6110 AND MEASUREMENT SOLUTIONS www tegam com e mail sales tegam com Model 1820 MEASUREMENT PRODUCTS RF Mount Temperature Controller or two mounts e LEDs and Analog Meters are conve niently located on the front panel Economical easy to use compact and light weight One year warranty Prices and specifications subject to change without notice The Model 1820 RF Mount Temperature Controller provides a stable power source for one or two Precision RF Coaxial Power Standards mounts The Model 1820 maintains the mount at operating temperature reducing warm up t
81. R FR FF N CONF HD WONKF DCO o 1000 1 10 100 1000 Frequency kHz Figure 3 Maximum Vpp vs Frequency Amplifier s maximum peak to peak output roll off with frequency This is due to the amplifier s slew rate of 250 V uSec Figure 4 Distortion Typical Distortion measurements were made operating the amplifier at 75 of the maximum Vpp output obtained from Figure 3 This data sheet was current when it was produced However products are constantly being updated and improved Because of this some differences may occur between the descriptions herein and the current product Prices and specifications may be changed without notice BACK TO CONTENTS TEN TEGAM WAY GENEVA OHIO 44041 440 466 6100 FAX 440 466 6110 www tegam com e mail sales tegam com TEGAM YOUR GLOBAL SOURCE FOR TEST AND MEASUREMENT SOLUTIONS WaveWorks Jr 6 Math Operations e Sequence Programming Digital Patterns FFT and IFFT Analysis Tools e Supports CSV amp PRN ASCII Data Formats Free with purchase of TEGAM 2100 Series Arbs GPIB and RS 232C Compatible lj Wave Math Wave 3 SOFTWARE Basic Waveform Creation Software for 2700 Series AWGs Versatile Waveform Solution WaveWorks Jr is a fundamental software tool used to create edit upload and download arbitrary waveforms to and from your 2700 series arbitrary waveform generators It turns your computer screen into a virtual wa
82. REMENT SOLUTIONS F 3 F 4 Model 3550 42 0 HZ TO 5 00 Specifications Measurement Parameters MHZ PROGRAMMABLE Ls Lp Inductance Cs Cp Capacitance Rs Rp Resistance IZI Impedance IYI Admittance G Conductance B Susceptance X Reactance D Dissipation Factor Tan Delta Q Quality Factor 0 Phase Angle V Inter Terminal Voltage I Inter Terminal Current LCR METER Depends on the measurement frequency and signal voltage Comments L gt 320nH 750 0kH C gt 0 160pF 37 0mF R gt 0 001mQ 199 99MQ ZI gt 0 001mQ 199 99MQ IYI gt 5 000nS 100 00S G gt 5 000nS 100 00S B gt 5 000nS 100 00S x gt 0 001mQ 199 99MQ D gt 0 0001 9 9999 Q gt 0 1 1999 9 0 180 00 180 00 V gt 0 00V 5 00Vrms I gt 0 00mA 99 99mA Measurement Ranges 9 Auto Manual Ranges 100mQ 102 109 1009 1kQ 10k 2 100kQ IMQ 1OMQ Typical Basic Accuracy 0 10 Dependent Upon Test Variables and Measured Impedance Measurement Frequency 42 0Hz 5 00MHz 0 01 Frequency Accuracy Output Impedance 50Q 10 Output Voltage Amplitude 42Hz 1 00MHz 1 01 MHz 5 00MHz 0 01 5 00Vrms 0 05 1 00Vrms 10 10mV Programmable Test Voltage 20 10mV Programmable Test Voltage Output Current Amplitude 42Hz 1 00MHz 1 01MHz 5 00MBz 0 01 99 99mArms 0 05 20 00mArms 10 10 4A Programmable Test Curren
83. TEGAM Temperature Stabilized Coaxial RF Power Transfer Standards enable the precise measurement of microwave power in the 10 MHz to 18 GHz frequency range These units are extremely rugged highly accurate and stable with time and temperature They are ideal for use as standards for the transfer of calibration factors to other RF standards and power sensors Units are supplied with ANSI NCSL Z540 1 1994 NIST traceable calibration data A2LA Accredited Calibrations are optional These models are designed for use with dc self balancing bridges such as the TEGAM Model 1806 and 1804 or controllers such as the TEGAM Model 1805B System configurations employing instruments of this extreme accuracy typically achieve calibration factor Prices and specifications subject to change without notice BACK TO CONTENTS transfer results normally found only in primary standards laboratories The Model F1109 is a feedthrough Thermistor Standard and Power Splitter combination used for the calibration of bolometer thermocouple and diode terminating power sensors The F1109H is a Thermistor Standard Attenuator and Power Splitter combination It is used as a feedthrough standard for the calibration of higher power terminating sensors up to 250 mW This combination provides broader bandwidth and lower VSWR than other solutions when calibrating IW to 5W terminating sensors at typical operating power levels The Model M1110 is a te
84. Term Accuracy These specifications are guaranteed for the standard warranty period and are typically maintained for the life of the instrument Long term accuracy is implied when not otherwise stated Calibration Accuracy Calibration accuracy is the accuracy of TEGAM calibration data relative to the legal units maintained by the U S National Institute of Standards and Technology This data sheet was current when it was produced However products are constantly being updated and improved Because of this some differences may occur between the descriptions herein and the current product Prices and specifications may be changed without notice BACK TO CONTENTS Models SR102 104 YARDS amp Highest accuracy and stability Lowest temperature coefficients e Widest selection Temperature coefficient comparison between a typical TEGAM model and typical 1 ohm standard resistor TRANSPORTABLE RESISTANCE STANDARDS TYPICAL 10 STANDARD RESISTANCE CHANGE IN ppm 18 19 20 21 22 23 24 25 26 27 28 29 30 31 TEMPERATURE IN C 100Q Standards These standards were designed to provide an important link between rather odd Quantum Hall resistance values and traditional decade resistance values 100Q provides unique reference capability 10KQ Standards This has been the long standing industry standard for the 10kQ This everlasting standard is the benchmark for high accuracy stability and low temperature coeffi
85. UR GLOBAL SOURCE FOR TEST AND MEASUREMENT SOLUTIONS Model PRT 73 Standard Resolution to 0 Optional Resolution to 0 01 ppm 1 ppm Terminal Linearity 0 9 ppm e Wide bandwidth 10 Hz to 20 kHz e Standard 0 35 V Hz 350 V Max Optional 2 5 V Hz Overload protection Front panel display for easy set up and operation EASUREMENT INSTRUMENTS Automated Precision Ratio Transformer The PRT 73 Automated Precision Ratio Transformer meets or exceeds all of the requirements for a calibration stan dard in precision measurement applica tions It is easily integrated into systems for either automated or manual calibra tion of ratio dividers transformer stan dards synchro resolver standards transformers calibrators and voltmeters The PRT 73 is fully programmable via a standard IEEE 488 interface Storing calibration procedures in the system con troller increases the repeatability of mea surements The PRT 73 increases calibration throughput while maintaining data integrity by allowing measurements to be taken without operator intervention A local switch allows operators to change from remote programming to front panel operation providing precise control in delicate null balancing situa tions Calibration certificates are easily printed using data collected from the PRT 73 A convenient menu mode provides easy access to IEEE 488 address and setup commands Address and string terminators
86. URE RH TEMP PROBE TRANSMITTER Remote Stainless Steel Probes HTRH W 2 5 Wall Mounted HTRH D 8 5 Duct Mounted Relative Humidity 3 RH to 95 RH range 2 RH Temperature 40 to 180 C at 0 5 C Time constant under 4 seconds e 40 C to 180 C 40F to 356 F Operating Range e 2 RH 0 5 C Accuracies Power Inputs 7 to 30 VDC polarity protected Outputs 4 to 20 mA for 0 to 100 RH 4 to 20mA for 40 C to 180 C This data sheet was current when it was produced However products are constantly being updated and improved Because of this some differences may occur between the descriptions herein and the current product Prices and specifications may be changed without notice TEGAM YOUR GLOBAL SOURCE FOR TEST AND MEASUREMENT SOLUTIONS BACK TO CONTENTS TEN TEGAM WAY GENEVA OHIO 44041 440 466 6100 FAX 440 466 6110 www tegam com e mail sales tegam com EW3 XXXX EW5 XXXX cost to you for the life of the program This program is offered in three year and five year increments WARRANTY BENEFITS Your instrument is returned to full functionality All performance problems for the entire Extended Warranty Period are resolved by TEGAM at no additional cost to you The cost of this program is much less than the cost of our standard repair service Your repair costs are paid in advance and will not be subject to future budget cuts You avoid future repair service c
87. With No Accessories 300 60 uQ Breakdown Voltage 1500 volts peak to case Oil Bath Type Mineral oil Penreco Drakeol 9 white Insulation Resistance Typically 10 4 Q cm Quantity Approximately 0 5 gallons Dimensions with oil Height 4 7 in 120 mm Width 4 6 in 117 mm Depth 13 2 in 335 mm Mass Weight 10 Ibs 6 35 kg Operating Environment Temperature 22 8 3 3 C 73 6 F Humidity 20 to 50 relative humidity Safe Operating Environment 0 to 50 C 32 to 126 F 15 to 80 relative humidity Temperature Humidity Order Information SR1030 Resistance Transfer Standard System Part No 1 Q Resistance Transfer Std SR1030 1 10 Q Resistance Transfer Std SR1030 10 100 Q Resistance Transfer Std SR1030 100 1 KQ Resistance Transfer Std SR1030 1 K 10 kO Resistance Transfer Std SR1030 10 K 100 kQ Resistance Transfer Std SR1030 100 K Options SB103 Shorting Bars SB103 PC101 Parallel Compensation Network PC101 SPC102 Series Parallel Compensation Network SPC102 Calibration amp Technical Services For warranty and remedial repair calibration services and spare parts or for additional information on TEGAM sales and service offices around the world contact us at 440 466 6100 ph or 440 466 6110 fx This data sheet was current when it was produced However products are constantly being updated and improved Because of this some differences may occur between the descriptions herein and t
88. able readings of distorted waveforms When there is no voltage present the unit automatically tests for continuity ground faults or shorts Plus it has all the features of the Model 120 The Model 122 has the same specifications and functions as the Model 120 but has a continuity tester a backlit display and audible tone for AC DC continuity All Models also feature Molded on probes with retractable probe tip covers Dual probe holder with positive lock probe extension for safe easy two hand operation e Splash proof dust proof and withstands 6 ft drop to concrete Auto power off Automatic selection ACV or DCV One Range No ranges or functions to select e Safety and Productivity at an affordable price ACCURACY 0 296 rdg 1 volt DC and 50 60 Hz RESOLUTION 1 volt ENVIRONMENTAL OPERATING LIMITS 10 F to 150 F DISPLAY 0 5 LCD 3 digits annunciators for VAC VDC OL polarity and low battery SIZE WEIGHT 6 99 x 27 91 27 02 Oz WARRANT Y 1 year materials and labor Wiggy is a registered trademark of Square D Company Simpson and 260 are registered trademarks of Simpson Electric Co ORDERING INFORMATION MODEL RANGE VOLTS AC and DC MAXIMUM INPUT CONTINUOUS INPUT RESISTANCE OVERLOAD TEST VOLTS TRMS 5 sec REJECTION OF CAPACITIVE COUPLED INPUTS CONTINUITY TEST 122 125 750 750 750 750 5KQ 5KQ ES FS 1500pF 1500pF YES YES This data sheet was current
89. andard GPIB Interface Options WaveWorks Pro Waveform Creation Software Rack mount kit Prices and specifications subject to change without notice GENERATORS High Speed AWG Comprehensive Features The 2416B has an independently variable sample clock that ranges from 0 01S s to 100MS s It offers 12 bit vertical resolution and 68k of active waveform memory Standard or arbitrary waveforms are created through the front panel or optional WaveWorks Pro software High quality signal production and true arbitrary waveform generation make the 2416A an ideal solution for high sample rate precise signal applications Signal Integrity Waveforms will always be consistent and repeatable because the 2416A is a true Arbitrary Waveform Generator Other generators use phase accumulator based addressing which compromises waveform integrity by skipping or repeating waveform data points Function Generator Simplicity Front panel access to nine standard waveforms and their settings provides function generator simplicity for general lab use For test applications where custom signals are required up to 99 unique waveforms may be stored in waveform memory en mingen PARANAETER ameron Firm MOD Ce CJc e BACK TO CONTENTS Unlike most arbs the 2416A allows a direct frequency setting of the custom waves from the front panel Once programmed into the 2416A s memory all waveforms are available fo
90. asure temperatures from 70 F to 300 F 55 C to 150 C with precise accuracy 0 3 of the reading They re built dust proof splash proof withstand a six foot drop and work with all YSI Series 400 probes Those outstanding qualities along with their repeatability and long term stability make these handheld thermometers ideal for work in the lab or in the field e Accuracy 0 3 of reading e 1 or 0 1 resolution e F or C scales Big easy to read LCD display ORDERING INFORMATION One year warranty MODEL INPUTS SCALE 865 One E 866 One C TEGAM s 868 869 100Q RTD thermometers the only handheld RTDs that accept three wire and four wire platinum probes and provide repeatable accuracy of 0 3 C With exceptional accuracy and the same repeatability and long term stability of our thermistor units TEGAM s 868 869 platinum RTD thermometers detect and display temperatures from 360 F to 1100 F They re ideal for cryogenic and high temperature research or industrial monitoring For your flexibility we provide a mating connector which allows you to use any 100 ohm RTD probe These units are housed in heavy duty ABS cases that are dust proof splash proof and drop proof Accuracy 0 3 C 1 or 0 1 resolution e F or C scales Big easy to read LCD display ORDERING INFORMATION One year warranty MODEL INPUTS SCALE 868 One al 869 One x SPECIFICATIONS ACCESSORIES SUPPLIED 9V battery a
91. ation factors When used with bolometer element RF Power Standards mounts such as the TEGAM Model F1109 the 1805B permits the accurate transfer of up to 132 calibration frequencies traceable to NIST from 0 01 to 18 0 GHz The 1805B is also compatible with other TEGAM System IIA components including all TEGAM RF Power Transfer Standards refer to applicable data sheets for mount specifications An internal temperature controller raises and maintains the temperature of the mount chamber above ambient This minimizes the effects of changes in ambient temperature for all TEGAM RF iii 19 TUTTI TAN f M X Eos BACK TO CONTENTS Power Transfer Standards The 1805B operates in a closed loop configuration for leveling the RF output of compatible signal sources These sources are controlled directly using an analog signal applied to a dc coupled AM input connector Ultra stable dc high precision metal film resistors provide dc power increments across a TEGAM patented self balancing bridge The front panel bridge meter provides visual indication that closed loop stabilization has been achieved and enables rapid system operation Coarse and fine adjustments are provided to obtain a meter null reading with no RF applied In addition to the bridge balance and temperature indicator the 1805B contains several operational and performance checks A front panel Mount Error indicator blinks if the voltage across the mount is not wit
92. ations Prices and specifications subject to change without notice MEASUREMENT PRODUCTS Single Type IV RF Power Meter The Model 1804 Single Type IV RF Power Meter is designed for use with bolometer elements and an external DVM to measure high frequency power microwave power and insertion loss It can also function as a standard for the calibration of RF detectors RF voltmeters and bolometer elements mounts manufactured by TEGAM Weinschel and Agilent HP Mounts easily interface to the 1804 s universal front panel binding post connection Calibration of temperature compensated mounts can be performed by adding the TEGAM Model 1820 RF Mount Heater The exclusive use of 100 DC substituted power eliminates the effect of AC components on the bridge circuit which has been shown to introduce a substantial error in the substituted power due to the short term time constant of some bolometer elements Substituted DC power levels ranging from 0 01mW to Single Type IV AF Power Meter BACK TO CONTENTS Mode 1804 30mW can be measured to within 0 003 which makes this an ideal instrument for insertion loss measurements Regardless of the application all measurements can be made directly traceable to primary voltage and resistance standards The Model 1804 Type IV RF Power Meter is designed to bias either 100 or 200 ohm mounts and is thus compatible with Aligent HP 478A 486A and 8478A thermistor mounts when used
93. atts 47 to 420 Hz 105 to 125 Vac standard or 210 to 250 Vac with a factory installed option Weight Physical Dimensions 17 7 lbs 8 03 kg Height 3 5 in 88 9 mm Width 18 in 457 2 mm Depth 15 4 in 390 7 mm Rack Mounting The Model 1827 can be mounted in a standard 19 rack with rack mount kit RM 1825 Additional Equipment Required Signal Generator DVM RE Power Meter 100 kHz to 18GHz Frequency Range Continuous Wave 6dBm minimum power output Two may be required to cover the entire frequency range DC Volts 6 1 2 digit minimum Compatible with the sensor under test This data sheet was current when it was produced However products are constantly being updated and improved Because of this some differences may occur between the descriptions herein and the current product Prices and specifications may be changed without notice 9 amp a Certificate no 2018 01 BACK TO CONTENTS TEN TEGAM WAY GENEVA OHIO 44041 440 466 6100 FAX 440 466 6110 www tegam com e mail sales tegam com IEGAM YOUR GLOBAL SOURCE FOR TEST AND MEASUHEMENT SOLUTIONS Model F1109 M11 to Thermistor Standards are temperature controlled 0 01 mW to 25 mW dynamic range can be extended to 250 mW Primary and Working Transfer Standard configurations e Cased version also available Optional A2LA Accredited calibrations MEASUREMENT Coaxial RF Power PRODUCTS Transfer Standards
94. atures High quality signal production and true arbitrary waveform generation make the 2714A an unmatched combination of price and performance for high sample rate extended memory applications The 2714A offers 12 bit vertical resolution with over 128k of horizontal memory It has a variable sample rate that ranges from 0 1S s to 20MS s This product is ideal for testing I and Q modulation profiles radar or sonar simulations complex electromagnetic simulation ultrasound detector emulation and a host of other applications Multiple Unit Operation Each 2714A is equipped with a synchronous trigger output The synchronous output allows external instruments including two or more 2714A units to be hardware triggered by a master 2714A unit This produces multiple phase signals with highly accurate phase offsets Because the 2714A uses the raster scan technique and sequential addressing there is no need to recalibrate phase offsets every time a frequency change is made DDS type generators require this recalibration Systems Ready The Model 2714A is a low cost version of the Model 2414B It has the same basic performance capabilities but is designed specifically Prices and specifications subject to change without notice BACK TO CONTENTS for systems applications where low cost and performance are valued higher than extended front panel functions 2714A includes standard RS 232C and GPIB interfaces WaveWorks M Jr wave c
95. ber of the instrument warranted This program offers three full years of calibration and repair services starting from the date of shipment TS5 XXXX XXXX is the model number of the instrument warranted This program offers five full years of calibration and repair services starting from the date of shipment This data sheet was current when it was produced However products are constantly being updated and improved Because of this some differences may occur between the descriptions herein and the current product Prices and specifications may be changed without notice BACK TO CONTENTS TEGAM YOUR GLOBAL SOURCE FOR TEST AND MEASUREMENT SOLUTIONS K 4 Our customer service team is always ready to help you Repair amp Calibration Services Today s fast paced technological environment requires that quality throughput and cost effectiveness are maximized in order for your business to thrive TEGAM realizes that your test instruments are indispensable to your company and directly affect the success and profitability of your business Regular evaluation and calibration of NIST traceable standards pays dividends Regular instruments with service ensures that your quality level meets or exceeds your customer s expectations maintains high quality production levels lowers operating costs and optimizes the performace of your test instrumentation All TEGAM service and calibration services meet or ex
96. bration readings are affixed to instrument Dimensions Height 6 4 in 16 25 cm Width 17 in 43 2 cm Depth 5 6 in 14 2 cm Weight 8 5 lbs 3 9kg net Standard Equipment Model SR1050 comes with a 6853 instruction manual Initial Accuracy The specifications stated in the TEGAM instrument catalogs and data sheets are intended as acceptance specifications and are guaranteed for 60 days from the date of shipment They are typically maintained for a much longer period of time Long Term Accuracy These specifications are guaranteed for the standard warranty period and are typically maintained for the life of the instrument Long term accuracy is implied when not otherwise stated Calibration Accuracy Calibration accuracy is the accuracy of TEGAM calibration data relative to the legal units maintained by the U S National Institute of Standards and Technology This data sheet was current when it was produced However products are constantly being updated and improved Because of this some differences may occur between the descriptions herein and the current product Prices and specifications may be changed without notice TEGAM BACK TO CONTENTS YOUR GLOBAL SOURCE FOR TEST TEN TEGAM WAY GENEVA OHIO 44041 AND MEASUREMENT SOLUTIONS 440 466 6100 FAX 440 466 6110 www tegam com e mail sales tegam com Model DB62 1Q through 1 11111 MO 10 O through 11 1111 MO 0 01 Initial Accuracy Serves DC through A
97. can be easily configured into an attenuation measuring system with the addition of the TEGAM VM 7 and a signal source This system is capable of performing attenuation measurements from 0 01 to 18 GHz For detailed and block diagrams of such a system refer to the Model 8850 Attenuation Measurement System data sheet The Frequency range can be extended even further to 40 GHz with the addition of the Model 8853 Frequency Converter specifications YOUR GLOBAL SOURCE FOR TEST AND MEASUREMENT SOLUTIONS B 4 Model 8852 FREQUENCY CONVERTER Specifications Input Frequency Range Low Band 10 MHz to 2 GHz High Band 2 GHz to 18 GHz Frequency Resolution 1 kHz from 01 to 2 GHz 2 kHz above 2 GHz Maximum Input Level 20 dBm Nominal Impedance 50 Q Mixer Compression 1 dBm 1 dB compression SWR at RF Input Connector Low Band 0 01 2 GHz 3 0 maximum High Band 2 18 GHz 3 0 maximum Conversion Gain RF IN to 30 MHz Noise Figure 0 6 dBm nominal from 0 01 to 18 GHz 12 dB maximum Output Frequency 30 2 MHz Internal 10 MHz Reference Frequency Stability ppm 0 to 50 C Oscillator Output Level 8 dBm 1 dBm External 10 MHz Reference Input Impedance 50 Q Oscillator Input Level 8 dBm 1 dBm Aux Output 2 to 18 GHz 7 2 5 dBm Operation IEEE 488 bus control or VM 7 Local mode Note only if the VM 7 I O card has been upgraded with two bus ports and applicable software
98. ceed the performance criteria for accuracy and reliability as defined in the MIL45662 and ANSI NCSL Z540 1 1994 calibration standards In addition we are accredited in accordance with ISO IEC 17025 1999 from A2LA as specified in Certificate Number 2018 01 Does TEGAM Offer Support for Your Instrument TEGAM designs develops and manufactures a broad line of test measurement and calibration equipment In addition to providing exceptional repair and calibration service for the products manufactured by TEGAM TEGAM offers calibration amp repair services for a large number of products formerly manufactured by Tektronix Weinschel Eaton Electro Scientific Industries ESI Gertsch Keithley Pragmatic and more To find out whether TEGAM can provide you with the service that you need please go to our Product Support Directory at www tegam com where you can look up the service amp support status of your YOUR GLOBAL SOURCE FOR TEST AND MEASUREMENT SOLUTIONS www tegam com instrument by model number You can also contact TEGAM by phone 440 466 6100 or complete the online service inquiry form for service information about your product Preparation for Shipment to TEGAM We take pride in our commitment to customer service and product support and wish to provide you with the best quality of service possible In order to do this it is necessary to clearly document the nature of service that is required for a particular
99. ceptional accuracy 0 196 with 0 1 resolution F and C Repeatability 0 2 typical 6 Data logging registers Trend indicators on 820 821 show rising falling or stable temperature Annunciators display status of all functions e Self diagnostics show low battery open TCs overrange or internal hardware faults Drop proof dust proof and splash proof ABS case NIST traceable certificate of calibration available upon request Two year calibration guarantee three year warranty These thermometers are extraordinary IREN TYRES 346 to 1400 92D 10 foc 210 to 760 200 to 400 DIMENSIONS 7 x 2 9 x 1 1 Net weight 10 oz This data sheet was current when it was produced However products are constantly being updated and improved Because of this some differences may occur between the descriptions herein and the current product Prices and specifications may be changed without notice BACK TO CONTENTS TEGAM YOUR GLOBAL SOURCE FOR TEST AND MEASUREMENT SOLUTIONS Thermometers Accurate easy to use Probe is available in 12 18 and 24 lengths deal for measuring the temperature of soups brines and combo boxes RS AND PROBES Heavy Duty Food Processing Thermometer Temperature quality control in the food processing environment requires highly rugged thermometers that are accu rate and easy to use To address these demands TEGAM introduces the new model 86104
100. ch Resistors virtually eliminate switch transients e Ratio range from 0 0111111 to 1 1111110 Prices and specifications subject to change without notice EASUREMENT INSTRUMENTS Decade Ratio Transformer Standard Model DT72A is an inductive voltage divider that meets or exceeds all of the requirements for a calibration standard in precision measurement applications It is easy to integrate into systems for calibration of voltage dividers transformer standards synchro resolver standards transformers calibrators ammeters and voltmeters It can also be used to make impedance or capacitance comparisons The ratio accuracy is traceable to the National Institute of Standards and Technology This variable AC voltage divider demonstrates extreme precision for measuring and generating voltage ratios Seven decades of tapped transformer windings are selected using special low resistance switches providing 0 1 ppm resolution and 0 9 ppm terminal linearity The key to these standards is extremely stable toroidal transformers resulting in precision and outstanding long term BACK TO CONTENTS Standard Decade Trans formar stability over a wide range of environmental conditions The seven in line control knobs permit quick easy setting of the required ratios The first dial has end stops to prevent accidental switching from zero to full output The other dials rotate independently through 360 of rotation
101. cients for calibrations requiring NIST traceability Prices and specifications subject to change without notice INSTRUMENTS Transportable Resistance Standards The TEGAM team of precision Transportable Resistance Standards are oil filled hermetically sealed five terminal resistance standards designed for precision bench top or oil bath applications The long term stability of these resistance standards is typically less than 0 2 ppm per year and temperature coefficients are less than 0 1 ppm per degree Celsius This excellent long term stability and low temperature coefficient is achieved by using matched groups of resistors constructed of the alloy Evanohm R The resulting low temperature coefficient allows high performance applications of these standards inside or outside an accurately controlled temperature environment Maximum accuracy is calculated as a temperature corrected resistance value This is accomplished by using the BACK TO CONTENTS built in RTD temperature sensor to measure the internal temperature and referencing a temperature correction chart provided with each unit The measurement accuracy of the built in RTD thermometer is better than 0 1 degree Celsius Very low power coefficients are achieved by using standard resistors constructed with large surface areas like Model SRI04 10kQ standard resistor The resistors are our original surrounded by oil to conduct heat generated by the
102. cing for banana plugs Temperature Operating 12 to 32 C 4 54 to 90 F Storage 40 to 475 C 40 to 167 F Warm up time 2 hours minimum from instrument power up Power Requirements 12 Watts 47 to 420 Hz 105 to 125 Vac standard or 210 to 250 Vac with a factory installed option Weight 17 2 lbs 7 4 kg Physical Dimensions Height 3 5 in 88 9 mm Width 18 in 457 2 mm Depth 15 4 in 390 7 mm Rack Mounting The Model 1825 can be mounted in a standard 19 rack with rack mount kit RM 1825 Additional Equipment Required Signal Generator DVM RF Power Meter 10 MHz to 18GHz Frequency Range Continuous Wave 6 dBm minimum power output DC Volts 6 1 2 digit minimum Compatible with the sensor under test This data sheet was current when it was produced However products are constantly being updated and improved Because of this some differences may occur between the descriptions herein and the current product Prices and specifications may be changed without notice aa Certificate no 2018 01 BACK TO CONTENTS TEGAM P TEN TEGAM WAY GENEVA OHIO 44041 YOUR GLOBAL SOURCE FOR TEST 440 466 6100 FAX 440 466 6110 AND MEASUREMENT SOLUTIONS www tegam com e mail sales tegam com Model 1827 MEASUREMENT PRODUCTS Economical Wideband RF Power Sensor Calibrator for labs wi nual calibration workloads of 40 RF power sensors or less Can calibrat
103. components alike Holders may also be adjusted from 0 75 1 90cm to 3 0 7 62cm apart allowing use of the fixture with many component sizes and configurations Terminal contact pressure is also adjustable Pressure may be reduced for easy insertion of components with small gauge leads Contacts are gold plated beryllium copper 17504 measurement of surface resistance Each Kelvin probes allow the probe has two spring loaded pins spaced 1 8 apart Pins are replaceable 17505 Male LEMO Connector and Strain Relief is an optional accessory that allows you to interface your existing handlers or probe sets to the new 1750 Resistance Measuring System 17508 Calibration Standard is a convenient calibration standard that makes calibrating your 1750 quick easy and accurate The NIST traceable 17508 provides easy connections and provides a discrete standard for each of the 1750 s 1l resistance ranges Ordering Information 1750 Resistance Measuring System includes Model 17509 Operation amp Service Manual 17501 Kelvin Klip Set and NIST Traceable Certificate of Calibration 17501 Kelvin Klip Set 17502 Spade Lug Adapter 17503 Sorting Fixture 17504 Kelvin Probes 17505 Male LEMO Connector amp Strain Relief 17508 Calibration Standard 17509 Operation amp Service Manual Opt Z540 Calibration Data Report amp NIST Traceable Certificate of Calibration Call us toll free at TEGAM at 800 666 1010 f
104. compromises waveform integrity by skipping or repeating waveform data points Phase shifted and amplitude varied waveforms used in complicated sequences are easily generated with the 2414B GENERATORS AWG with Extended Memory Comprehensive Features The 2414B has an independently variable sample clock that ranges from 0 1S s to 20MS s It offers 12 bit vertical resolution and 128k of active waveform memory Standard or arbitrary waveforms are created through the front panel or optional WaveWorks Pro software High quality signal production and true arbitrary waveform generation make the 2414B an ideal solution for high sample rate precise signal applications including MEMS actuators and micro engines bearing failure assessment I and Q modulation biofeedback simulation multi phase signal generation conventional signal generation and much more Function Generator Simplicity Direct front panel access to 20 standard waveforms with user definable parameters provides function generator simplicity for general lab applications For test applications where custom signals are required up to 1 000 unique waveforms may be stored in waveform memory Once programmed all waveforms are available for direct recall and editing from the front panel or RS 232C or GPIB optional interfaces Programmable Synchronous Outputs Each 2414B is equipped with four independently controlled synchronous outputs Sync outputs allow external i
105. d 10MHz 26 5GHz A 11 MR 1 Motor Rotation Indicator H 3 OCS0550 ee OCSO550 DP OCS2500 Oscilliscope Calibration SSUSIGEI anda air ereire ARRS PAV w MF PAV w MF 2 aa PAV w MF 3 0 PAV W SF 1 PAV W VF 1 PAV w VF 2 enn PC101 Parallel Compensation Network for SR1010 1030 amp LOGO C C 23 uto Q 9 PGS506A 22uoxeeeudhrret dos EE ut PRETIO ea PRIZ coedecisive ot bx Ries 9 PRT 73 Programmable Precision Ration Transformer C 21 PRT 73 2 5 Programmable Precision Ratio Transformer w 2 5 Volt Hz Option C 21 Contact TEGAM Inc at 440 466 6100 for information INDEX BY MODEL NUMBER PS503A Triple Power Supply PS5004 Power Supply PS5010 Power Supply Mote Lo ee ae RS925A RS925C RS925D 1 2 M ohm Decade Resistance Standard 5 09 W eee 9 HDI 2 2 UERUNPREWO RES EE 9 FUND ee bes eu Ee T PEE EE Dr 9 BIS liene oS eee tees oe eee HIIG 12 Rr EPESIGE GARS Lir ne er ae ee bees Soe ee sa HPEISA 625080552 hood baad iias Ql Mc 9 RT 20A 9 HPE2SA 2o ts Pid rod
106. d even when turned off The dual input models allow you to view T1 T2 or Tl minus T2 or to continual ly scan all three modes Their six data logging registers automatically record the minimum and maximum tempera tures of all three modes simultaneously These thermometers are more accurate with accuracies of 0 196 and a resolution of 0 1 full range in F and C You get fast accurate and repeatable readings and an unmatched two year ORDERING INFORMATION MODEL TCTYPES INPUTS 819 KJ T One 820 K J Two 821 KEUS SPECIFICATIONS ACCURACY 0 1 rdg 0 6 C RESOLUTION 0 1 1 F OR C DISPLAY 5 digit LCD 0 4 high ACCESSORIES SUPPLIED Integral tilt stand handle wrist strap 9V battery manual two 8712 probes with 820 821 one 8712 probe with 819 REPEATABILITY 0 2 C 0 36 F typical THERMOCOUPLES RANGE TYPE K oF 328 to 2502 C 200 to 1372 Innovative Handheld Digital calibration guarantee to prove it All models conform to the temperature voltage tables of the National Institute of Standards and Technology and to IEC 584 standards One Touch keys let you Change TC types K J T Change resolution from 0 1 to 1 e Switch to F or C Hold display values One Touch keys on TEGAM s 820 821 also let you e View or continuously scan T1 T2 and T minus T2 e Record min max data View recorded data e Scan recorded data All Models also feature Ex
107. d for proficiency testing Proficiency testing is part of the requirement that is being driven by laboratory accreditation to ISO IEC 17025 1999 General Requirements for the Competence of Testing and Calibration Laboratories Participation in proficiency testing is a valuable quality improvement tool allowing the participant to gain insight into your measurement processes This translates into improved performance and enhanced measurement quality Utilization of NAPT by TEGAM Inc allows our organization to receive unbiased analysis of measurement processes to enhance our awareness of our technical competence and data integrity This very important feedback allows TEGAM Inc to provide you our customer with the best possible integrity and confidence in our calibration techniques and data YOUR GLOBAL SOURCE FOR TEST AND MEASUREMENT SOLUTIONS K 6 Please contact TEGAM at 440 466 6100 or visit our website at www tegam com for Our Product Support Directory Applications Notes Local Sales Representatives Applications Assistance Education amp Training Information TEN TEGAM WAY GENEVA OHIO 44041 8 BACK TO CONTENTS TEGAM YOUR GLOBAL SOURCE FOR TEST 440 466 6100 FAX 440 466 6110 AND MEASUREMENT SOLUTIONS www tegam com e mail sales tegam com INDEX BY MODEL NUMBER 001 306 National Instruments GPIB Interface Card for System IA and 8850 LP ok 102 373 2 Power Splitter for F
108. d in a sturdy formica veneered wooden case having a removable lid and carrying handle Other versions are packaged in a sturdy stainless steel container Ordering Information Resistance Transfer Standard SR102 100 Ohm Bench Top Case SR102 DC 100 Ohm Case Deleted SR104 10 000 Ohm Bench Top Case SR104 DC 10 000 Ohm Case Deleted Calibration Documentation Contact TEGAM for OPTION Z540 NIST Traceable Compliance Certificate and Test Data Standard Equipment Each TEGAM Resistance Transfer Standard includes an instruction manual and temperature coefficient chart Warranty One year on materials and workmanship Calibration amp Technical Services Contact TEGAM for warranty and remedial repair calibration services and spare parts or for additional information on TEGAM sales and service offices around the world Contacting TEGAM For more information contact TEGAM at 800 666 1010 toll free 440 466 6100 phone 440 466 6110 fax sales tegam com e mail www tegam com This data sheet was current when it was produced However products are constantly being updated and improved Because of this some differences may occur between the descriptions herein and the current product Prices and specifications may be changed without notice TEGAM YOUR GLOBAL SOURCE FOR TEST AND MEASUREMENT SOLUTIONS BACK TO CONTENTS TEN TEGAM WAY GENEVA OHIO 44041 440 466 6100 FAX 440 466 6110 www tegam com
109. dicated on the front panel with high visibility LEDs This simplifies setup and programming verification Sixteen AC Measurement Parameters This meter provides accurate and repeat able measurements of 16 different parame ters with a basic accuracy of 0 10 Readings are easily viewed on the three dis plays Display A provides 4 2 digit readings of Inductance L Capacitance C Resistance R Impedance IZI or Admittance IYI Display B indicates 4 2 digit measurement values for Dissipation Factor D or Tan 9 Quality Factor Q Equivalent Series Resistance Rs Equivalent Parallel Resistance Rp Phase Angle 0 Conductance G Reactance X or Susceptance B Display C provides a 4 digit reading of the output voltage V output current I or test fre quency f All parameters are easily programmed or selected from the front panel and annuncia tors clearly indicate the active setting Measurements can be taken as either series or parallel equivalents Prices and specifications subject to change without notice BACK TO CONTENTS Designed for Component Testing With over 4 500 programmable frequen cy points accurate frequency characteriza tion of components or materials is straightforward The three instrument mea surement modes Voltage Mode Constant Voltage Mode and Constant Current Mode allow the user to control the test signal inde pendent of the DUT impedance A built in comparator with 1
110. e frequency band of 01 to 18 GHz The 8852 extends the VM 7 s capabilities to measure devices at frequencies other than 30 MHz Other features include Aux Output This RF output supplies a 2 to 18 GHz synthesized continuous wave signal in 2 KHz steps at 7 dBm which can be used as a signal source for other applications IEEE 88 Bus Programmable The Model 8852 operational parameters are controlled over the IEEE 488 compatible bus using an external controller or an upgraded VM 7 with applicable software 10 MHz Ref Input Output This instrument will either accept or provide a 10 MHz reference signal for system operation Rack Mounting This instrument can be stacked easily with other TEGAM instruments or LIBRI SIL SES LILEESJ BACK TO CONTENTS mounted in any cabinet or rack designed according to MIL STD 189 or EIA RS 310 using the appropriate rack mounting kit P N 187 1007 1 Weinschel PLANAR CROWN Connector System The use of Weinschel PLANAR CROWN connectors at the two INPUT connectors provides the Model 8852 user with easy exchange of connector types and eliminates the need for adapters and other devices that would create additional insertion loss This Torque Free type of connector also provides quick replacement of defective connectors All crowns will mate nondestructively with connectors per MIL STD 39012 refer to Weinschel PLANAR CROWN data sheet for more details System Operation The Model 8852
111. e Step and Ramp Functions Free Statement of Traceability e Shirt pocket size Drop proof Splash proof and Dust proof case Two year calibration guarantee plus three year warranty SPECIFICATIONS ACCESSORIES SUPPLIED Statement of Traceability universal calibration adaptor amp cable integral tilt stand hanger wrist strap 9V battery manual ACCURACY 0 5 F 0 3 C rdg gt 50 F K J T E N 18 to 28 C ambient 0 2 F 0 1 C rdg gt 50 F RTD 0 5 F 0 3 C Thermistor RANGE TYPE K TYPES INRE T TYPE E le 328 to 2502 346 to 1400 328 to 752 382 to 1832 C 200 to 2502 210 to 760 200 to 400 230 to 1000 For other ranges and accuracies see the Calibrator Features Chart at www tegam com DISPLAY 5 digit LCD DIMENSIONS 7 0 x 2 9 x 1 1 Net weight 12 oz ORDERING INFORMATION SENSOR TYPES K ay ies IN elise 6 1B J T E 10000 100KQ 1002 RTD amp Thermistor J T E N B R S G C D 10009 10KQ 1009 amp 10009 RTD This data sheet was current when it was produced However products are constantly being updated and improved Because of this some differences may occur between the descriptions herein and the current product Prices and specifications may be changed without notice YOUR GLOBAL SOURCE FOR TEST BACK TO CONTENTS AND MEASUREMENT SOLUTIONS D 1 Calibrator Accessories TEMPERATURE CALIBRATORS THERMOMETE RS Calibration Kits TEGAM Calibration Kits ar
112. e accuracy high resolution and constant input impedance of the Kelvin Varley circuit They provide known voltage and current ratios for meter calibration linearity checking ratio measuring synchro testing computer standardization and many other DC and audio frequency applications The stacked dial conserves space without sacrificing configuration operating ease Each unit occupies less than 45 2 square centimeters of panel space Convenient in line reading is provided by the TEGAM Dekadial coaxial dial The DP 1211 offers two decades plus a 100 division potentiometer The DP 1311 offers three decades plus a 100 division potentiometer Exceptional stability and reliability are assured by the use of precision resistive elements The ceramic switch decks are silicone treated to improve insulation resistance and the multiple switch contacts are of solid silver alloy for long life and low contact resistance All components are shock mounted within the sturdy dust cover BACK TO CONTENTS YOUR GLOBAL SOURCE FOR TEST AND MEASUREMENT SOLUTIONS C 15 C 16 Models DP 1211 DP 1311 DEKAPOT DECADE POTENTIOMETERS Specifications Standard Equipment DP 1211 Dekapot Decade Potentiometer Models DP 1211 and DP 1311 come with Terminal Linearity Initial 15 ppm 0 5 dial division an 8895 Instruction Sheet Long term 20 ppm 0 5 dial division
113. e installed separately or any two units may be combined side by side 138 652 1806 or 1804 to HP Thermistor Mount Cable Cable used to connect HP Temperature Compensated Thermistor Mounts to a TEGAM Type IV Power Meter The second set of spade lugs are for monitoring the temperature compensation thermistor beads with the second bridge on the 1806 or with a second 1804 This data sheet was current when it was produced However products are constantly being updated and improved Because of this some differences may occur between the descriptions herein and the current prod uct Prices and specifications may be changed without notice 138 652 ie TEG AM D YOUR GLOBAL SOURCE FOR TEST BACK TO CO NTENTS AND MEASUREMENT SOLUTIONS A 21 RF Mount Splitter Support Bracket A O This sturdy support bracket prevents rotation of Feedthrough Thermistor Mount splitters dur BACK TO CONTENTS TEN TEGAM WAY GENEVA OHIO 44041 A 28 YOUR GLOBAL SOURCE FOR TEST 440 466 6100 FAX 440 466 6110 AND MEASUREMENT SOLUTIONS www tegam com e mail sales tegam com Model VM 7 e Rack mount kit available e Resolution down to 0 001 dB e 0 060 dB accuracy Built in diagnostic software Very fast and easy to use e Optional A2LA Accredited Calibrations The TEGAM Model VM 7 offers users great flexibility in configuring a measuring system cost effectively Since the VM 7 is a 30
114. e many popular sensors in 30 minutes or less The accuracy and reliability you have come to expect from TEGAM e No software to learn Compact and easy to use All connectors are located on the front panel for easy connection e Rack mount kit available Optional A2LA Accredited Calibrations NOTE Customer must provide an appropriate RF Signal Source DVM and an RF Power Meter for the UUT The Model 1827 RF Power Sensor Calibrator is an accurate economical and reliable instrument The broad frequency range of 100 kHz to 18 GHz makes the Model 1827 an ideal choice for calibrating a wide variety of sensors while keeping annual calibration costs low Previous calibration systems required two standards to achieve this range and annual calibration costs were thousands of dollars more VSWR and accuracy have not been sacrificed to achieve the broad frequency range of this instrument The Model 1827 detects the level of RF power being applied to an RF power sensor Resulting voltage readings are measured by the customer supplied DVM Cal factors for the UUT are determined by comparing the readings of the DVM with the readings of the customer supplied Power Meter Cal factors are obtained by performing a few simple calculations The Model 1827 is a cost effective non automated version of the popular TEGAM System IIA No additional software is supplied or required The Model 1827 offers the same accuracy and reliability a
115. e mounting in standard 19 racks It measures less than 8 X 4 X 7 WxHxD and weighs 5 1 2 pounds But don t let its size fool you the 3525 is packed with functional ity and value Easy to Use The 3525 s user friendliness was implemented as a design specification Anyone can use this device and begin taking accurate and repeatable readings immediately The easy to use front panel makes instrument operation totally intu itive There is no need to search hidden submenus to find the instrument s set tings All settings are indicated on the front panel with high visibility LEDs Comparator with External Buzzer A built in GO NO GO comparator makes the 3525 an ideal choice for man ual verification of component values for QA or manufacturing An audible beeper increases efficiency by eliminating the need for the user to read the display Total test time and operator errors are significantly reduced A front panel lock feature prevents accidental changes of instruments settings High Performance at a Low Cost No other LCR meter has the performance density of the 3525 This innovative solu tion for cost sensitive LCR applications is accurate and fast in manual or auto mated applications The 3525 performs basic LCR measurements better than Agilent s most cost effective solution at less than half its price The Model 3525 is backed by a full 3 year warranty and TEGAM s 30 day no risk trial If for any reason you are not satis
116. e that the 2004 2005 TEGAM catalog will be of help to you and your organization If you have a measurement production test or calibration problem that other test equipment manufacturers have not solved please contact us We look forward to the opportunity to tackle your challenges Terry A Gambill President TEGAM Inc TABLE OF CONTENTS Contact TEGAM ii PRODUCTION TEST nmm E Arbitrary Waveform amp Function Generators CALIBRATION 16 bit True AWG 1 A RF Power Sensor Calibration AWG with Extended Memory 3 Power Sensor Calibrators 1 High Speed AWG 5 RF Power Transfer Standards 5 Low Cost 16 bit AWG 7 Bo RF Power Level Controller 15 Low Cost AWG with Extended Memory 9 Single Type IV Power Meter lg Amplifiers for Waveform Generators 11 Dual Type IV Power Meter 19 Waveform Creation Software 13 RF Mount Temperature Controller 21 Power Sensor Calibration Software 23 LCR Meters Power Sensor Calibration System HA 25 General Purpose Programmable LCR Meter 1 RF Power Sensor Accessories 27 42 0 Hz to 5 00 MHz Programmable LCR Meter 3 RF Attenuation Measurement Ohmmeters D Advanced 30 MHz Receiver 1 High Speed Micro Ohmmeter 1 Frequency Converter 0 01 18 GHz 3 Frequency Converter 18 40 GHz 5 GENERAL TEST Attenuator Calibration Software H Electrical Safety Meters E Attenuation Measurement System 9 Safety Voltmeters 1 Attenuation Accessories 12 Voltmeter Accessories 2 Phase Testers 3 Resistance amp Ratio Standards Standard Resistor 1 Digital
117. e what you need to calibrate temperature devices and check temperatures throughout your plant No matter what sensor type or connection method these kits let you calibrate and check temperature controllers recorders process monitors panel meters and transmitters The heart of each TEGAM Calibration Kit is the 800 Series handheld temperature calibrator sold separately that combines bench meter performance with a data logging thermometer Take a look at everything that you get K J amp T Universal Adaptor Kits each adaptor kit contains a 3 calibration cable with spade lug terminals plus a standard connector and a subminiature connector AC Adaptor Battery Charger amp Rechargeable Battery Rubber Boot amp Belt Clip Type K Wire Temperature Sensor Foam Filled Carrying Case K J T amp E Alligator Clip Calibration Cables 4 Wire RTD Ohms Thermistor Alligator Clip Calibration Cable 2 RTD 4 Pin Connectors AC Adaptor Battery Charger amp Rechargeable Battery Rubber Boot amp Belt Clip Type K Wire Temperature Sensor Foam Filled Carrying Case NOTE Calibration Kits should be ordered by Kit along with the calibrator of your choice not included A High Impact Carrying Case as shown in Kit 1 amp 5 above This case has a foam insert for 840 and 850 Series Calibrators and 819 and 820 Series Thermometers ORDERING INFORMATION MODEL 5000 Rubber Boot and Belt Clip This rubber boot protects your instrument fr
118. easily calibrate controllers smart transmitters and panel meters Use the ramp feature to quickly check safety switch and alarm setpoints Convenient one touch keys select functions ge or Zl for both calibrator and thermometer Select sensor types calibrator or thermometer mode F SELEC or C view memory locations or hold a reading The 5 digit LCD annunciates all active functions Programming is a snap Enter calibrator set points through the calculator style keypad or program them from an outside source The step function allows one touch output of programmed values When turned off the units retain your programs for quick repeat use The thermometer mode provides accurate readings and ten memory locations let you record temperature measurements for later review Save Money Now you can calibrate and measure Thermocouples 100Q and 1000Q1 RTD s and 2252Q Thermistors All of your Temperature problems can be solved with one meter MEET ISO 9000 ISO 9000 and other quality programs require precise calibration on the factory floor TEGAM s meters conform to the tables of the National Institute of Standards and Technology and come with a free statement of traceability to help you meet ISO 9000 Choose up to 11 Thermocouple types RID Ohms and Thermistor functions 850 Series e 0 2 F 0 1 C RTD 0 5 F 0 3 C Thermocouple and Themistor Accuracy e Calibrator and Thermometer in one unit e 10 Memory locations
119. eater is connected with cables provided with the Models F1130 1805B 1806 and 1820 YOUR GLOBAL SOURCE FOR TEST AND MEASUREMENT SOLUTIONS Model F1130 M1130 COAXIAL RF POWER TRANSFER STANDARODS Specifications Frequency Range F1130 100 kHz to 18 GHz M1130 100 kHz to 18 GHz Power Range 0 01 to 25 mW 20 to 14 dBm 0 01 to 25 mW 20 to 14 dBm Nominal Impedance 50 Ohms 50 Ohms Max VSWR Power Linearity 1 06 from 100 kHz to 6 GHz 1 10 from 6 to 15 GHz 1 14 from 15 to 18 GHz 0 190 from 1 to 10 mW 1 30 from 100 to 500 kHz 1 10 from 0 5 to 4000 MHz 1 20 from 1 to 4 GHz 1 30 from 4 to 8 GHz 1 40 from 8 to 18 GHz lt 0 1 from 1 to 10 mW Insertion Loss 6 dB 9 dB max 1 5 dB max Individual calibrations traceable to NIST supplied at the following frequencies 100 200 455 kHz 1 1 25 3 5 MHz 10 to 100 MHz in 10 MHz steps 100 MHz to 2 GHz in 50 MHz steps 2 GHz to 4 GHz in 100 MHz steps 4 to 12 4 GHz in 200 MHz steps 12 75 to 18 GHz in 250 MHz steps 100 200 455 kHz 1 1 25 3 5 MHz 10 to 100 MHz in 10 MHz steps 100 MHz to 2 GHz in 50 MHz steps 2 GHz to 4 GHz in 100 MHz steps 4 to 12 4 GHz in 200 MHz steps 12 75 to 18 GHz in 250 MHz steps Calibration Factor Accuracy 0 80 from 0 1 to 10 MHz 1 00 from 0 01 to 10 GHz 1 10 from 10 to 18 GHz 0 80 from 0 1 to 10 MHz 1 20 from 0 01 to 10 GHz 1 30 from 10 to 18 GHz
120. ecade Initial 0 01 7mQ mQ typical See table Long term 0 02 10mQ Smallest Step Dimensions Resistance at Zero Setting 0 1 Q Height 5 9 in 15 0 cm Approximately 40 mQ Number of Decades Width 8 5 in 21 6 cm Breakdown Voltage Eight Depth 6 5 in 16 5 cm 1 000 V peak to case Total Resistance Weight 12 MQ 7 5 lb 3 4 kg net Model DB877 ratings per step for each decade Resistance Smallest Incremental Accuracy Coefficients Measurement Duty Peak Per Decade Step Maximum Ratings Voltage Initial Long term Temperature Power Power Current Q Q ppm C ppm mW step mW step mA V step 10M 1M 0 02 0 03 5 0 3 22 0 03 300 1M 100k 0 02 0 03 5 0 3 220 1 5 150 100k 10k 0 02 0 03 5 0 3 500 7 70 10k 1k 0 02 0 03 5 0 3 500 23 23 1k 100 0 02 0 03 5 0 3 500 71 7 100 10 0 03 0 03 15 0 9 500 230 2 3 10 1 0 1 0 12 20 1 2 500 710 0 7 1 0 1 1 0 1 0 60 6 250 1600 1 6 Intermittent use such that temperature rise of the resistor will not appreciably exceed that which would occur in free air ee 4 I l b xX b x X b x L Xx G 2ko 9 200 20 20 9 0 22 o l 9 9 9 f 9 9 I P 8 8 b 8 Wr 8 i o 2k0 o 200 0 3 2002 o 20 o 0208 o i 7 7 1 7 7 t7 i 6 6 6 6 be I Po 2kQ o 200 Q 2040 2060 020 amp 0 l 5 15 5 5 5 bi b 4 l 4 4 4 l 9 2k0 o 200 Q 2000
121. een the descriptions herein and the current product Prices and specifications may be changed without notice s Certificate no 2018 01 A 8 TEGAM Y YOUR GLOBAL SOURCE FOR TEST AND MEASUREMENT SOLUTIONS BACK TO CONTENTS TEN TEGAM WAY GENEVA OHIO 44041 440 466 6100 FAX 440 466 6110 www tegam com e mail sales tegam com Model F1130 M11 MEASUREMENT PRODUCTS Coaxial RF Power e Thermistor Standards are temperature controlled 0 01 to 25 mW dynamic range Primary and Working Transfer Standard configurations e Rack mount kit available e Optional A2LA Accredited calibrations Prices and specifications subject to change without notice Transfer Standards TEGAM Temperature Stabilized Coaxial RF Power Transfer Standards enable the precise measurement of microwave power now in the 100 kHz to 18 GHz frequency range With this wider frequency range the F1130 and M1130 can be used in applications that previously required two standards These units are extremely rugged highly accurate and stable with time and temperature They are ideal for use for the calibration factors to other RF standards as standards transfer of and power sensors Units are supplied with ANSI NCSL Z540 1 1994 NIST A2LA Accredited Calibrations are optional traceable calibration data These models are designed for use with dc self balancing bridges such as the TEGAM Model 1806 and 1804 or with control
122. elow 50 Hz Multiply by 50 f Hz Maximum Effective Series Output Impedance R approx 5 ohms maximum L 30 uH Input Impedance at 20 V and 400 Hz Approximately 500 K ohms minimum Input Inductance Approximately 100 to 400 H depending on excitation Output Current A maximum Dimensions 19 in 48 3 cm wide 5 1 4 in 13 3 cm high 7 1 in 18 cm deep Weight 18 lbs 8 1 kg net Standard Equipment The model DT72A comes with a 7203 instruction manual Calibration amp Technical Services For warranty and remedial repair calibration services and spare parts or for additional information on TEGAM sales and service offices around the world contact us at FIRST CORE SECOND CORE THIRD CORE FOURTH CORE 440 466 6100 ph or 440 466 6110 fx INPUT 1O 2 KO i o O MILLIRADIANS 1 erdo HHH OUTPUT AB GRD 10 STEPS 11 STEPS 11 STEPS 11 STEPS 11 STEPS 11 STEPS 11 STEPS ioa D LINEARITY 10 9 10710 107 10 6 105 104 10 3 10 2 SETTING LINEARITY VERSUS SETTING OUTPUT VOLTAGE LINEARITY DEVIATION INPUT VOLTAGE SETTING LINEARITY DEVIATION IN PROPORTIONAL PARTS 0 000 TYPICAL LINEARITY DEV ATION AT fikHz INPUT IMPEDANCE MAGNITUDE MAXIMUM PHASE SHIFT FREQUENCY IN KILOHERTZ PHASE SHIFT VERSUS FREQUENCY INPUT IMPEDANCE PHASE ANGLE IN DEGREES FREQUENCY IN KILO
123. ements of fixed or step attenuators manual or programmable Binary attenuators may be measured vertically or horizontally across any number of frequencies During the measurement process the data is plotted in real time in a graph window with attenuation vs frequency and numerically displayed in a spreadsheet style window shown Measurement data and an instrumentation list may be saved in an ASCII text file after completion of a measurement Multiple data files may be recalled and displayed side by side for Prices and specifications subject to change without notice UREMENT CAMLab for Windows Calibration and Attenuation Measurement Lab comparison of past data Additionally past and present calibration data files may be combined either numerically or graphically to allow comparison of attenuator performance Basic statistical functions are included to help the technician analyze the data and evaluate the performance of the attenuator or device under test MENU BAR Across the top of the CAMLab main window below the title bar and above the toolbar is the menu bar The menu bar consists of eight 8 drop down menus that are used to select most of the functions necessary to perform measurements and manipulate data The following is a list of the menu bar captions and their menu item functions File The File menu allows the operator to create new Frequency Files Edit Open previously saved data files and Save a n
124. emperature lagging effects as oil Refining Resistance Technology TEGAM s experience in design and manufacture of resistance standards has made TEGAM s standards highly respected throughout government and industry The SR1030 incorporates all the features of the SRIOIO Resistance Transfer Standards with the many benefits of a sealed oil bath Ideal as a Multi Value Standard Resistor or Reference Voltage Divider The high accuracy and precision of the individual resistors make the SR1030 ideal for use as a multi value standard resistor or reference voltage divider The superior stability of the SR1030 makes it particularly suitable for calibrating 6 1 2 7 1 2 and 8 1 2 digit digital multimeters Certified Traceable to the NIST The SR1030 Resistance Transfer Standard System is certified traceable to the National Institute of Standards and Technology You can use the SR1030 to transfer this traceability to your resistance standards and measuring equipment Certified calibration data is supplied with every standard YOUR GLOBAL SOURCE FOR TEST AND MEASUREMENT SOLUTIONS C 8 Model SR1030 RESISTANCE TRANSFER STANDARD SYSTEM Long Term Resistance Stability 20 ppm of nominal for 6 months 35 ppm for 2 years 50 ppm for 5 years typical Specifications Nominal Values per step 1 10 100 1 k 10 k and 100 kQ Transfer Accuracy 100 1 1 ppm 0 1 uQ at Temperature Coefficient parallel value using 1o 15 ppm
125. es ee MEASUREMENT TIMES READING RATE TIME TO FIRST READING FAST MODE 100 rdg sec nasal hh Miscellaneous Time to First Reading Display Modes Resistance Ohms Comparator Comparator Autoranging available in Resistance Mode Digital Interfaces TEEE 488 1 RS 232C RS 422 TRIGGER IN and READING DONE via BNC connectors Display 4 1 2 digit alpha numeric readout 2x16 characters backlighted LCD Measurement Method 4 terminal connection to the Device Under Test DUT Input Connector Heavy duty LEMO type for interface Environmental Operating 0 to 50 C lt 80 RH Storage 35 to 60 C lt 95 RH integrity and long life EMC Input Protection CE Class A EN 55011 IEC 801 2 IEC801 3 15V continuous ESD protected per Power IEC 801 2 Level 1 50 VA 120 240 VAC 10 Overload Current Dimensions Delay Mode 100 overshoot 25 u sec Fast Mode 200 overshoot 30 u sec Noise Rejection 60 dB typical at line frequency Height 5 2 13 3 cm Width 8 5 21 7 cm Depth 13 0 33 0 cm Weight 9 Ib 4 oz 4 2 kg Prices and specifications subject to change without notice BACK TO CONTENTS Calibration Full front panel calibration requires no internal adjustments and can be easily achieved on the production floor Recommended calibration equipment is TEGAM Model 17508 Calibration Standard or equivalent Calibration requires tempo
126. es with a variety of thermocouple readout devices including panel meters process monitors and analog meters With an optional extension cable the switchbox becomes a bench unit complete with rubber feet and built in tilt feature You can connect two or more switchboxes together for quick reading of multiple probe temperatures e One year warranty SPECIFICATIONS ORDERING INFORMATION ACCESSORIES SUPPLIED Instructions MODEL TCTYPES DIMENSIONS 5 x 2 8 x 1 5 Net weight 12 oz 8012 ACCESSORIES AVAILABLE 8668 vinyl carrying case 8022 80141 type K TC extension cable 8052 This data sheet was current when it was produced However products are constantly being updated and improved Because of this some differences may occur between the descriptions herein and the current product Prices and specifications may be changed without notice R TEGAM YOUR GLOBAL SOURCE FOR TEST BACK TO CONTENTS AND MEASUREMENT SOLUTIONS TEN TEGAM WAY GENEVA OHIO 44041 1 0 YOUR GLOBAL SOURCE FOR TEST 440 466 6100 FAX 440 466 6110 7 AND MEASUREMENT SOLUTIONS www tegam com e mail sales tegam com Humitran RS AND TRANSMITTERS thin film humidity sensor and Controlling Relative Humidity e 100 ohm Platinum RTD temperature sensor an d Te m pe rat ure Temperature compensated humidity output Factory calibrated Low cost RH 10V Bhamaiay Trans
127. ew or updated data file This menu also contains all of the Printer functions such as Printer Setup Print Preview and Print Data Edit This menu contains functions that are common to most Windows programs such as the ability to copy selected data from igi n a calibration data grid to the Cut Copy selected fields of data and the ability to Insert or clipboard Append Data from the clipboard into an open Data file Calibration Grid BACK TO CONTENTS pe Eat Setup Measurement Math Pretere Setup This menu allows the user to create and define a particular System Setup Once configured this setup can be easily saved to a file and reloaded when needed using this menu Measurement This menu allows the operator to define the measurement parameters and type of measurement run to be performed The operator can select from two types of measurement runs Selecting Auto will perform automatic measurement across a Selected frequency range Single Step will stop and prompt the operator before each measurement is performed Math This menu contains all of the CAMLab Math functions to calculate Standard Deviation Mean Median Calibration Deviation and SWR within a calibration data file Preferences This menu allows the operator to select certain preferences that can be used when operating CAMLab Real Time Data Graph Real Time Test Data Menu Bar Icons t Mi 1 Maa
128. fied with the performance of the instrument you can return it for full credit TEGAM YOUR GLOBAL SOURCE FOR TEST AND MEASUREMENT SOLUTIONS F 2 GENERAL PURPOSE PROGRAMMABLE LCR METER Specifications Measurement Parameters L Inductance C Capacitance R Resistance IZI Impedance D Dissipation Factor Tan Delta Q Quality Factor 0 Phase Angle V Inter Terminal Voltage I Inter Terminal Current Comments 1 6000uUH 199 99kH 0 9400pF 199 99mF 0 0100Q 199 99MQ 0 0100Q 199 99MQ 0 0001 19 999 0 5 199 99 180 00 180 00 0 00V 1 00V 0 00mA 10 00mA 4coogRmar V Y Y Y Y Y Y Y Y Measurement Ranges Ten Programmable Ranges Typical Basic Accuracy 0 08 Dependent Upon Test Variables and Measured Impedance Measurement Frequency 1kHz 120 Hz 0 01 Frequency Accuracy Output Impedance 100Q 10Q Output Amplitude 50mV 500mV 1 00V 10 10mV Programmable Test Voltage Maximum Short Circuit Current 10mA Measurement Ranges 0 10 LOOM Q 10 Ranges Auto or Manual Modes NOTE Measurement Ranges are based on Z Values other than Z are calculated values Measurement Modes Series or Parallel Equivalent Circuit Auto or Manually Selected Displays Dual High Visibility 4 1 2 Digit LED Displays Measurement Speed MODE FREQUENCY 120Hz 1kHz FAST 40mS 15mS NORMAL 90mS 50mS SLOW 360mS 250mS
129. ft straight cord Time constant 3 sec Accuracy 2 2 C or 0 75 o 8 1 2 ees o III 4 Sro POO orale P aran o E Compact General Purpose Immersion Probes Multi purpose for measuring air liquids soft materials e g water ice cream etc Sheath 316 SS TPR coil cord 1 ft ext 5 ft Time constant 1 sec Accuracy 8733 2 2 C or 0 75 TC TYPE MAX TEMP MODEL 8753 1 0 C or 0 75 K 390 F 200 C 8733 T 390 F 200 C 8753 Compact Penetration Probes For measuring semi soft materials within a restricted temperature range Sheath 316 SS TPR coil cord 1 ft ext 5 ft pe 3 oS s Time constant 1 sec Accuracy 2 2 C or 0 75 2 um d TC TYPE MAX TEMP MODEL tg HERES K 6907 2007 8734 This data sheet was current when it was produced However products are constantly being updated and improved Because of this some differences may occur between the descriptions herein and the current product Prices and specifications may be changed without notice 8 BACK TO CONTENTS TEGAM TEN TEGAM WAY GENEVA OHIO 44041 4 YOUR GLOBAL SOURCE FOR TEST 440 466 6100 FAX 440 466 6110 AND MEASUREMENT SOLUTIONS www tegam com e mail sales tegam com RTD Thermistor Th a ad a RS AND PROBES TEGAM s 865 866 2252Q thermistor thermometers Your best choice for lab accurate temperature measurement in a built tough handheld TEGAM s thermistor thermometers me
130. gam com e mail sales tegam com System IIA SYSIIA SureCal calibration software included e Substituted power levels 0 5 mW and 1 0 to 10 mW in 1 mW steps 0 1 1 pW e Calibration factor transfer repeatability 0 1 e Calibrates power sensors from 100 kHz to 40 GHz e Transfer Standards include NIST traceable calibration data with as many as 141 calibration points e Optional A2LA Accredited Calibrations System IIA is used primarily for the transfer of calibration factors to thermistor thermocouple and diode type RF power meter sensors Accurate measurement of signal source output level can also be performed Using power ratio methods variable amp step attenuators and attenuation measuring equipment can be calibrated Receiver amplifier or attenuator linearity can also be measured Calibration of RF power sensors is faster and more accurate than any other system with the TEGAM System IIA This IEEE 488 bus controlled product transforms a slow and costly task into a quick and accurate procedure The calibration speed of the System IIA is typically 5 seconds per measurement frequency The settling time of the power MEASUREMENT PRODUCTS Automatic RF Power Sensor Calibration System The System JIA can be used manually via front panel controls The task of calibrating power sensors is fully automated by the SureCal calibration software Precision RF Power Source In its most elementary form Sy
131. gs of the DVM with the readings of the customer supplied power meter Cal factors are obtained by performing a few simple calculations A Microsoft Excel spreadsheet with the formulas inserted is included with the instrument The Model 1825 is a low cost non automated version of the popular TEGAM System HA No additional software is supplied or required The Model 1825 offers the same accuracy and reliability as other TEGAM test instruments The 1825 is not a microprocessor controlled instrument but it is simple to operate Since measurements are taken with an external DVM the 1825 could be integrated into an automated workstation depending on the DVM used and the customer s ability to provide the appropriate software The Model 1825 s Thermistor RF Power Standard is built in internally temperature controlled so changes in ambient temperature will not affect power measurements The Type IV Bridge Circuitry detects RF power by using the DC power substitution method DC power levels can be measured to within 0 003 The Model 1825 is simple to operate To calibrate a power sensor the operator connects the output from the customer supplied RF signal generator to the RF INPUT of the 1825 and the and input of the customer supplied voltmeter to the VOLTMETER red and black binding posts on the 1825 Connect the UUT to a customer supplied compatible power meter and to the SENSOR port of the 1825 and start taking measure
132. he current product Prices and specifications may be changed without notice TEGAM YOUR GLOBAL SOURCE FOR TEST AND MEASUREMENT SOLUTIONS BACK TO CONTENTS TEN TEGAM WAY GENEVA OHIO 44041 440 466 6100 FAX 440 466 6110 www tegam com e mail sales tegam com Model SR1050 100kQ to 110MQ Eleven equal value precision resistors Two models decade steps 1MO to 10MQ Complete control of insulation resistance in resistance transfers Prices and specifications subject to change without notice DS amp INSTRUMENTS High Resistance Transfer Standard Precise transfer measurements up to 110MX2 relative to a single 100kQ resistance standard can be obtained with the Model SR1030 High Resistance Transfer Standard The unit is available in two models IMQ and 10MQ resistance sections Based on a unique method for establishing known ratios the Model SRI050 standard utilizes a transfer technique that consists of switching resistance sections in parallel series or series parallel sections An outstanding design feature is a structure in which the only insulation leakage paths other than those within each resistance section are from the external terminals to ground This eliminates insulation leakage errors in the transfer of calibration from one resistance level to another using three terminal measurement techniques A specially designed lever switch provides a convenient means of switching into parallel a
133. he the desired frequency input allows the user to increase the measurement systems dynamic range with the lowest possible SWR effects This configuration can perform measurements in either the 0 01 2 GHz band or the 2 18 GHz band depending on the Model 8850 front panel connection Using the Model 8852 as a CW signal source and adding the TEGAM MAIN GPIB BUS Masking Attenuator ller ab Software 8 Bus Card Attenuation Measurement System Model 8850 COMPUTER Masking Attenuator pouce 0 01 2 GHz Splitter Model 8853 will allow the Model 8850 to process frequencies up to 40 GHz in coax Refer to the Model 8853 data sheet for more information and actual configuration diagram This configuration is available as a system Model 8850 40 Return Loss SWR Measurements The TEGAM SWR Measurement Kit P N 187 4001 1 can be used with the Model 8850 and the CamLab Windows Software to perform return loss measurements The SWR Measurement Kit includes a return loss bridge with an open and short Because the Model 8850 operates as a single channel receiver it can be used as a scalar system The DUT s impedance to 50 ohms can be checked as a scalar quantity by measuring return loss The actual measured return loss can be readily converted into SWR by the system software 30 MHz IF Gain Measurements Active devices having gain can also be
134. hin a specified range This alerts the operator of a mount fault such as open or shorted leads or improper mount temperature DC supply voltages are monitored by PCB mounted LEDs which illuminate with an active power supply A standby mode switch allows mount heater circuit operation to maintain mount temperature at all times This ensures full performance capability and long term stability of the bolometer mount TEGAM YOUR GLOBAL SOURCE FOR TEST AND MEASUREMENT SOLUTIONS Model 1805B POWER LEVEL CONTROL Specifications DC Power Substitution Level Range Accuracy Bias Power Range Power Level Control Range UNIT 0 5 1 through 10 mW 30 0 7 mW bias power 0 1 5 uW 29 31 mW automatic with error indication for out of range balance condition 3 23 dB minimum Leveled RF Power referenced to DC 3 dB substituted power Dynamic Range Unbalanced Detector Sensitivity 2 AW division Resolution 0 2 uW Leveler Loop Gain 80 dB Temperature Controller Bias Power Temperature Sensitivity 2 wWI C per hour Ambient Temperature Dynamic Range 12 C to 40 C 454 to 104 F Mount Warm up Time 2 hours Internal Temperature Loop Gain 60 C 140 F nominal 80 dB minimum Open Loop Frequency Response 0 1 Hz Warm up Drive saturated 8 10 V 200 mA minimum Indicator Voltmeter Operating Modes Local Manual front panel control of all unit functions Remote IEEE 488 full function Bus Control
135. hrough in high speed production test since the laser trimmer The 1750 is the first fully integrated multi mode bus controllable high speed digital ohmme ter designed to outperform all other ohm meters and enhance the performance of the world s fastest laser trimmers and material handlers It s Fast The 1750 accelerates the high speed production line with TRUE SPEED performance In the Fast Mode the 1750 can set up zero out thermal errors acquire data and make its first reading in less than 12 milliseconds with an accura cy of up to 0 05 That s TRUE SPEED readings are provided every 10 millisec performance Subsequent onds at a true rate of 100 readings per second TRUE SPEED allows you to maximize the speed of your PLC s mater ial handlers and production line machinery The 1750 is fast because it provides speed and accuracy while automatically rejecting thermal and line noise Patented circuitry eliminates thermal and electro magnetic measurement errors caused by contact between device handlers and the device under test The 1750 rejects DC and AC noise offsets while maintaining its high speed test performance This unique feature is only found on the TEGAM 1750 It s High Powered The 1750 s power is in the user s abil ity to quickly configure it through a Prices and specifications subject to change without notice MMETER High Speed Micro Ohmmeter selection of standard setup menus Wi
136. ibration data A2LA Accredited Calibrations are optional Prices and specifications subject to change without notice BACK TO CONTENTS These models are designed for use with dc self balancing bridges such as the TEGAM Model 1806 and 1804 System configurations employing instruments of this extreme accuracy typically achieve calibration factor transfer results normally found only in primary standards laboratories The Model 1107 8 is a Thermistor Standard and Waveguide coupler combination The Model 1107 8 comes with a waveguide termination With the termination installed it is a terminating standard that can be used to calibrate feedthrough type power standards and for other applications requiring direct measurement of RF power With the termination removed the Model 1107 8 is a feedthrough standard used for the calibration of bolometer thermocouple and diode power sensors This model features a WR 28 waveguide flange Bias connectors are binding posts with standard 0 75 spacing for banana plugs The connector for the internal heater is compatible with the heater control circuit on TEGAM Models 1805B 1806 and 1820 YOUR GLOBAL SOURCE FOR TEST AND MEASUREMENT SOLUTIONS Model 1107 8 WAVEGUIDE RF POWER Specifications Frequency Range TRANSFER STANDARD 1107 8 without termination 26 5 to 40 GHz 1107 8 with termination 26 5 to 40 GHz Power Range 0 01 to 10 mW 20 to 10 dBm
137. ient does not exceed 0 03 ppm C over the temperature range of 18 C to 28 C This performance is as a passive device without ovens or external power requirements Internal Temperature Sensor The internal temperature sensor is a 1 000 ppm C RTD with integral thermowell provided for calibration Hermetic Sealing The resistor is hermetically sealed in oil with metal to glass seals to eliminate the effects of humidity Pressure Effects Normal changes in atmospheric pressure will not effect the value of these resistors This means that measurements made at NIST in Gaithersburg MD sea level will be consistent with measurements made at NIST in Boulder CO 5 280 ft or 1 6 km Termination Five terminal construction four terminal resistor with ground intercept for the standard and temperature sensor The four resistor binding posts are gold plated tellurium copper to reduce thermal emf The ground terminals are brass Thermal emf Under normal conditions thermal emf at the terminals does not exceed 0 1 uV Thermal Lagging Thermal lagging time constant is one hour minimum 1 l e of total change in one hour Dielectric Soakage Effect The resistance stabilizes to within 0 1 ppm of final value within 5 seconds with 1 V applied to the resistor Current Reversal The resistance value changes less than 0 ppm with reversal of current through the resistor Packaging The bench top versions are mounte
138. ime Simply connect the mounts and in two hours they are temperature stable Leave the mounts connected and they remain at operating temperature Connect the mount to your Model 1804 Model 1806 or System II at any time and begin to take measurements The 1820 is an economical alternate voltage controller providing a stable source to the mount s internal thermal BACK TO CONTENTS coils which is essential for thermistor temperature elevation This is critical for RF Mount stability and performance This unit is compatible with all TEGAM RF Power Standards The 1820 is designed to be used on the bench or in a rack Two mounts can be placed either on top of behind or beside the unit Standard equipment 12 inch control includes two four wire temperature cables with knurled lock collars An optional three foot temperature control cable is also available An easy to follow manual provides step by step instructions on its operation and maintenance YOUR GLOBAL SOURCE FOR TEST AND MEASUREMENT SOLUTIONS A 21 Model 1820 RF MOUNT TEMPERATURE Specifications Temperature Controller Bias Power Temperature Sensitivity Mount Warm Up Time Ambient Temperature Dynamic Range Internal Temperature Loop Gain Open Loop Frequency Response Warm Up Drive saturated Indicator CONTROLLER 2uW C per hour 2 hours 12 C to 40 C 4 54 to 104 F 60 C 140 F nominal 80 dB minimum 0 1 Hz 8 10 V 200mA
139. imensions Diameter 3 35 in 8 5 cm Depth 7 2 in 18 3 cm Depth behind panel 5 4 in 13 7 cm Weight 2 5 lbs 1 1kg net Standard Equipment Model DT1145 comes complete with an 8896 Instruction Sheet 100kQ2 IN OHMS 10kQ EZ INPUT IMPEDANCE MAGNITUDE 1kQ 0 01 0 1 1 10 100 0 1 STEP 10 STEPS 0 01 STEP 10 STEPS INPUT IMPEDANCE PHASE ANGLE 0 001 STEP 10 STEPS IN DEGREES Calibration amp Technical Services For warranty and remedial repair calibration services and spare parts or for additional information on TEGAM sales and service offices around the world contact us at 440 466 6100 ph or 440 466 6110 fx 188 DIA 4 HOLES PANEL MOUNTING 1 1 FREQUENCY IN KILOHERTZ ACCURACY IN DIAL DIVISIONS SWITCHING TRANSIENT SUPPRESSION RESISTOR 1 FREQUENCY IN KILOHERTZ ACCURACY VERSUS FREQUENCY e il 0 001 1 10 FREQUENCY IN KILOHERTZ PHASE SHIFT VERSUS FREQUENCY MAXIMUM PHASE SHIFT IN MILLIRADIANS 0 00001 DIVISION 100 DIVISIONS This data sheet was current when it was produced However products are constantly being updated and improved Because of this some differences may occur between the descriptions herein and the current product Prices and specifications may be changed without notice C 20 BACK TO CONTENTS TEN TEGAM WAY GENEVA OHIO 44041 440 466 6100 FAX 440 466 6110 www tegam com e mail sales tegam com TEGAM YO
140. improved Because of this some differences may occur between the descriptions herein and the current product Prices and specifications may be changed without notice Outputs Main Output Sync Output Clock Out Reference Out Sync Trigger Out Inputs TRIG IN CLOCK IN REF IN Trigger Sources Manual Trigger Ext Trigger Input Creation Tools Front panel S50Q impedance Front panel TTL sync output 50 2 impedance Rear panel AWG waveform sample clock output TTL X2 sample clock Rear panel internal 10MHz reference output TTL Rear panel BNC TTL for multiple unit operation Rear panel TTL trigger input for triggered gated toggled burst and master slave modes Rear panel sample clock input TTL 4MHz Rear panel 10 MHz reference input The internal crystal controlled oscillator will phase lock to the input Front panel button Rear panel BNC connector WaveWorks MjJr for Windows Operating System PC Requirements Interfaces Standard Functions Math Operation Sequence Creation Waveform Analysis Windows 95 98 XP amp 2000 486DX or better with 4MB RAM COM port or National Instruments AT GPIB card or equivalent 21 6 Operators 12 Transfer Functions Optional hardware required Frequency Domain FFT and IFFT up to 500th Time Domain Edit Computer Interface RS 232C GPIB General Temperature Range Operates Storage Dimensions
141. imum Dynamic range Wide Band 0to 110d Bm 0 01 to 18 GHz Narrow Band 0 to 103 dBm 10 to 300 MHz 0 to 112 dBm 300 to 1000 MHz 0 to 117 dBm 1000 MHz to 18 GHz Linearity Accuracy FREQUENCY ACCURACY RANGE dBm 10 to 300 MHz 0 100 10 dB 0 01 dB 10 to 20 0 005 10 dB 0 01 dB 20 to 86 0 100 10 dB 0 01 dB 100 to 103 300 MHz to 1 GHz 0 100 10 dB 0 01 dB 10 to 20 0 005 10 dB 0 01 dB 20 to 95 0 100 10 dB 0 01 dB 100 to 112 1 to 18 GHz 0 100 10 dB 0 01 dB 10 to 20 0 005 10 dB 0 01 dB 20 to 100 0 100 10 dB 0 01 dB 100 to 117 Attenuation Accuracy 0 015 dB System Repeatability 0 005 10 dB 0 to 80 0 100 10 dB 80 to 105 Exclusive of SWR effects and connector repeatability 1 18 GHz Operation Remote using IEEE 488 bus control Compatible with IEEE 488 STD 1987 or manual using VM 7 Local mode This data sheet was current when it was produced However products are constantly being updated and improved Because of this some differences may occur between the descriptions herein and the current product Prices and specifications may be changed without notice s Certificate no 2018 01 YOUR GLOBAL SOURCE FOR TEST BACK TO CONTENTS AND MEASUREMENT SOLUTIONS B 11 Attenuation Accessories RF ATTENUATION MEASUREMENT 187 4001 Attenuation Measurement Accessory Kit no photo Attenuation measurement accessory kit for the 8850 system This measurement accessory kit is carefully compri
142. instrument There are certain steps that you can take to expedite the repair and or calibration of your instrument If these steps are taken TEGAM can ensure you that we will deliver our product services to you in the most efficient manner possible RMA Number Before shipment to TEGAM please contact us for an RMA return material authorization number This number is extremely important and is necessary to track your instrument during the service cycle Either contact TEGAM by phone 440 466 6100 or complete the online service inquiry form Complete an Expedite Service Form optional In addition to the assignment of an RMA number the handling of your instrument can be optimized by the completion of a Calibration amp Repair Service Expedite form The completion of this quick form is optional but it can reduce the turnaround time of your instrument significantly by providing our technicians with written instructions by you on the services that you require There is also space reserved for providing detailed symptoms or special repair instructions BACK TO CONTENTS TEN TEGAM WAY GENEVA OHIO 44041 440 466 6100 FAX 440 466 6110 e mail sales tegam com amp Accreditations A2LA Certification TEGAM Inc has always strived toward providing our customers with the highest possible level of quality service and reliability Our accreditation by the American Association for Laboratory Accreditation A2LA is
143. istance Incremental Accuracy Coefficients Measurement Duty Peak Per Decade Value R Maximum Ratings Voltage Initial Long term Temperature Power Power Current Q Q ppm C ppm mW step mW step mA V step 10M 1M 0 01 0 02 5 0 15 100 0 3 300 1M 100k 0 01 0 02 5 0 15 1000 3 2 300 100k 10k 0 01 0 02 5 0 15 1000 10 100 10k 1k 0 01 0 02 5 0 15 1000 32 32 1k 100 0 01 0 02 5 0 15 1000 100 10 100 10 0 012 0 025 15 0 45 1000 320 3 2 10 1 0 03 0 07 20 0 6 1000 1000 1 1 0 1 0 2 0 5 60 3 500 2200 0 2 0 1 0 01 2 5 400 60 160 4000 0 04 1 Refers to previous table 2 Intermittent use such that temperature rise of the resistor will not appreciably exceed that which would occur in free air This data sheet was current when it was produced However products are constantly being updated and improved Because of this some differences may occur between the descriptions herein and the current product Prices and specifications may be changed without notice BACK TO CONTENTS TEN TEGAM WAY GENEVA OHIO 44041 440 466 6100 FAX 440 466 6110 www tegam com e mail sales tegam com YOUR GLOBAL SOURCE FOR TEST AND MEASUREMENT SOLUTIONS Model DB877 eu UI e 0 01 Initial Accuracy Serves DC through Audio Frequency Applications e Great stability due to 5 ppm C Temperature Coefficient and 0 3ppm mW Power Coefficient for values 1 kQ and up e Short term switch repeatability 1 mQ typical
144. itrary Waveform and Function Generators e Compatible with any Signal Generator that can drive a 5002 impedance Excellent Choice for MEMS electrostatics or piezoelectric applications ENERATORS Single Dual Channel High Voltage Amplifiers The Models 2340 2350 are designed for applications that require high voltage amplification beyond the standard voltage limitations of most wave form function or pulse generators With a maximum output voltage of 400Vp p the Models 2340 2350 come standard with a fixed gain of 50 Gains from 10 to 100 are available by special order Each channel is rated for 40mA continuous current with 0 2Q output impedance Each channel has an inde pendent buffered voltage monitor out put for applications that require a low level representation of the output signal The buffers produce a reduction of 200 1 for 50Q inputs and 100 1 for IMQ and above inputs The output current is sensed in both directions by the current limit function This provides maximum protection to the amplifier during operation A built in power supply monitor protects the power amplifiers by tracking the DC power supply If a high voltage DC fault occurs the monitor will disconnect the power supply from the power amplifiers Cycling the supply power resets the fault The amplifiers can drive capacitive loads up to 200pF while maintaining a full power bandwidth exceeding 200kHz For maximum user safety the ou
145. l instruments including additional 2411B units to be hardware triggered by waveform events Because each output is fully programmable multiple sync pulses can be defined at any width or location within waveform memory Hardware sync is more precise than software sync enhances system performance and reduces development time Facilitates the Design of Complex Test Systems The RS 232C and optional IEEE 488 2 offer direct easy programming The 2411B has numerous triggering and timing inputs outputs for precise multi phase operation of several instruments Up to four slave arbs may be triggered by a single master 2411B With four sync outputs available from each slave 16 total outputs numerous instruments can be simultaneously triggered by a single waveform event Further expansion is limited only by propagation delay Extensive User Tools Expand the 2411B s memory up to 30 000 times with the optional sequence generator Each sequence program can have up to 1 000 steps which can link to any of the 2411B s 100 user defined waveforms Each waveform may be looped up to million times per step Up to one hundred unique sequence programs may be stored in the sequencer s non volatile memory WaveWorks Pro software optional is a total software solution for importing exporting creation and editing waveform data in up to seven formats including the common ASCII formats CSV and PRN See the WaveWorks Pro data
146. lers such as the TEGAM Model 1805B FREQUENCY RANGE CO NHeto 1 Ghe POWER RANGE 10 pW te 26 mW BACK TO CONTENTS System configurations employing instruments of this extreme accuracy typically achieve calibration factor transfer results normally found only in primary standards laboratories The Model F1130 is a feedthrough Thermistor Standard and Power Splitter combination used for the calibration of bolometer thermocouple and diode terminating power sensors The expanded frequency range has been achieved without compromising the VSWR or accuracy specifications The Model M1130 is a terminating thermistor Primary Transfer Standard It is designed to be calibrated directly by a national standards agency such as NIST The M1130 is used for the calibration of feedthrough devices such as bolometer mount coupler and bolometer mount splitter RF Standards It is also useful in other applications requiring direct measurement of RF power The VSWR of this model is better than the two standards it replaces and the accuracy is unchanged Both models have a wider frequency band than any other thermistor power standard in this range This reduces the number of standards needed to calibrate power sensors in the 100 kHz to 18 GHz frequency range and lowers annual calibration costs by up to 50 Both Models feature a Type N RF connector Bias connectors are binding posts with standard 0 75 spacing for banana plugs The internal h
147. life User Friendly Through the use of soft key user interface the operator is guided through the use of the instrument A Help function provides information on key operation precluding the need to refer to the manual in most cases Performance The VM 7 offers dynamic range of 127 dB when using the synthesized signal sources Single step measure ments are possible over the full dynamic range because the receiver is not encum bered by mechanically switched range changes The excellent accuracy built into the receiver translates into an accuracy of 0 060 dB for a single step 100 dB measurement Speed of Operation Advanced digital detection and pro cessing techniques means that measurements are available instantaneously no matter what the dynamic range or resolution Self Calibration A built in self calibration routine allows for automatic calibration of the BACK TO CONTENTS switched gain and attenuator stages in order to maintain the exceptional accuracy of the instrument Diagnostics and Service Complete diagnostic software has been built into the instrument to allow a technician to easily find a fault Should repair become necessary every module can be easily removed through the rear panel Rack Mounting This instrument can be stacked eas ily with other TEGAM instruments or mounted in any cabinet or rack designed according to MIL STD 189 or EIA RS 310 using the appropriate rack mounting kit Syste
148. llows MODEL DESCRIPTION you to convert your test leads to alligator 12501 Alligator Clip Adapter clips The kit includes two screw on 12502 Universal Adapter probe adapters and two heavy duty screw in alligator clips with insulating rubber boots These alligator clips open tons and fit most terminals and bus bars The 12502 probe adapter kit includes two screw on probe adapters and interchangeable screw in accessories including two alligator clips with insulating rubber boots two banana plugs two needle tips two spade lugs and two heavy duty tips With this kit you can adapt your voltmeter to the many different situations you encounter on the job This data sheet was current when it was produced However products are constantly being updated and improved Because of this some differences may occur between the descriptions herein and the current product Prices and specifications may be changed without notice m BACK TO CONTENTS TEGAM TEN TEGAM WAY GENEVA OHIO 44041 YOUR GLOBAL SOURCE FOR TEST 440 466 6100 FAX 440 466 6110 AND MEASUREMENT SOLUTIONS www tegam com e mail sales tegam com Electrical Safety Meters Prevent Costly Aa Damage 4 TEGAM s Phase Sequence Indicators show installers and servicepeople the correct way to make three phase connections and prevent costly damage Working where power is on TEGAM s Phase Sequence Indicators instantly and clearly identify A B C circuits There s no
149. m Configuration The Model VM 7 is easily config ured into an attenuation measuring system with the addition of the Model 8852 Frequency Converter and an RF signal source This system is capable of performing attenuation measurements from 0 01 to 18 GHz The Frequency range can be extended even further to 40 GHz with the addition of the Model 8853 Frequency Converter For detailed specifications and a block diagram of such a system refer to the Model 8850 Attenuation data sheet Measurement System TEGAM YOUR GLOBAL SOURCE FOR TEST AND MEASUREMENT SOLUTIONS B 1 B 2 Model VM 7 ADVANCED 30 MHz RECEIVER Specifications Input Frequency 30 2 MHz Sensitivity 110 dBm wideband 127 dBm narrow band Dynamic Range 110 dB wideband 127 dB narrow band Incremental Accuracy 30 MHz RANGE ACCURACY Wide Band 0 to 90 dBm 02 dB per 10 dB 90 to 100 dBm 0 04 dB per 10 dB Narrow Band 0 to 100 dBm 0 02 dB per 10 dB 100 to 110 dBm 0 04 dB per 10 dB 110 to 120 dB 0 12 dB per 10 dB Exclusive of Signal Source effects Automatic Frequency Control Output level 10 V maximum Calibration Source Internal or External 30 MHz at 55 dBm typical Int 10 MHz Reference Oscillator Ext 10 MHz Reference Oscillator Requirements Frequency Accuracy 0 0025 Frequency Accuracy 0 0050 0 dBm Input level Input Connectors 30 MHz Input Type N Female 10 MHz Reference Input
150. mV 1 of setting 20mV 100mV to 999mV ImV 3 of setting 5mV 10mV to 99 9mV 100uV 5 of setting ImV Note 50 2 source impedance measured at open circuit tested with kHz sine wave plus DC offset Analog Filter User selectable 7MHz 7th order low pass filter Operational Modes Continuous Triggered Gated Burst 1 to 1 048 575 Toggled Hold RTS Return to start Outputs Main Output Sync Outputs SYNC 1 OUT SYNC 2 OUT SYNC 3 OUT SYNC 4 OUT CLOCK IN OUT REF IN OUT Sync Trigger Out Front panel S0Q impedance SYNC 1 SYNC 4 AII fully programmable addresses amp widths Front panel TTL 50 2 Rear panel BNC TTL Rear panel BNC TTL Rear panel BNC TTL Rear panel sample clock I O TTL Rear panel internal or external 1OMHz reference TTL Rear panel BNC TTL for multiple unit operation Inputs SUM IN TRIG IN CLOCK IN REF IN HOLD IN RTS IN Trigger Sources Internal Trigger Manual Trigger Ext Trigger Input SUM IN allows external signal to be added to output Gain 2 open circuit and 1 with 50Q out put termination and 50Q input Z Rear panel TTL trigger input for triggered gated toggled and burst modes Rear panel sample clock input TTL 20MHz Rear panel 10 MHz reference input The internal crystal controlled oscillator will phase lock to the input Rear panel TTL input to stop waveform Rear panel TTL input t
151. me differences may occur between the descriptions herein and the current product Prices and specifications may be changed without notice BACK TO CONTENTS TEN TEGAM WAY GENEVA OHIO 44041 TEG A M 440 466 6100 FAX 440 466 6110 www tegam com e mail sales tegam com YOUR GLOBAL SOURCE FOR TEST AND MEASUREMENT SOLUTIONS WaveWorks Pro SOFTWARE Advanced Waveform Creation Software for All TEGAM AWGs Sequence Programming Digital Patterns e FFT and IFFT Analysis Tools e 8 Data Formats including ASCII CSV PRN Compatible with TEGAM Arbitrary Waveform Generators GPIB and RS 232C Compatible Versatile Waveform Solution WaveWorks Pro is the simplest way to create edit upload download arbitrary waveforms to and from your TEGAM arbitrary waveform generator It turns your computer screen into a virtual waveform palette WaveWorks Pro with its extensive waveform library and complete set of design and editing tools provides unlimited waveforms and waveform sequences when coupled to TEGAM arbitrary waveform generators Comprehensive Waveform Design Tools WaveWorks Pro comes with a comprehensive array of math operations and transfer functions designed to meet your most demanding wave shape requirements As an added analytical tool synthesis in both the time and Prices and specifications subject to change without notice BACK TO CONTENTS frequency domain is available by usi
152. measured by an attenuation measurement system such as the Model 8850 Extra attenuation is required for this application because the reference level is lower than the measurement level Depending on the frequency range of the active device the system can be used in either single or dual band operation Extra input attenuation will be required to decrease signal level by at least the value of the amplifiers gain so that the Model 8852 remains in its linear region If the amplifier is to be tested at a particular level extra attenuation may be inserted at the output of the device to achieve the correct operating levels Uncertainty values are similar to those for attenuation measurements However the distortion of the active device will make measurements level sensitive adding to the uncertainty BACK TO CONTENTS ATTENUATION MEASUREMENT SYSTEM Specifications Input Power Requirements 100 120 220 240 Vac 10 50 to 60 Hz all Instruments Environmental Operating Temperature 0 to 50 C 4 32 to 122 F Bo Storage Temperature 40 to 75 C 40 to 167 F Humidity 95 Input Frequency Low Band 0 01 to 2 GHz High Band 2 0 to 18 GHz Frequency Resolution Maximum Input Level 1 kHz from 01 to 2 GHz 2 kHz above 2 GHz To prevent damage 20 dBm Nominal Impedance 50 Q at RF input ports SWR at RF Input connector LOW BAND 0 01 2 GHz 3 0 maximum HIGH BAND 2 18 GHz lt 3 0 max
153. measuring currents out through the stainless steel case These precise characteristics facilitate laboratory comparisons without critical environmental controls and are used wherever a need for a very stable temperature coefficient is required accurate resistor of low TEGAM ft YOUR GLOBAL SOURCE FOR TEST AND MEASUREMENT SOLUTIONS C 3 Models SR102 104 TRANSPORTABLE RESISTANCE STANDARDS Specifications Stability ppm year the first 2 years 0 5ppm year thereafter Temperature Coefficient lt 0 1 ppm C at 23 C Power Coefficient Less than ppm W Initial Value SR102 SR102 DC SR104 SR104 DC ppm ppm Calibration Uncertainty SR102 SR102 DC 0 5 ppm SR104 SR104 DC 0 25 ppm Breakdown Voltage 500 Volts peak to case Power Rating Watt momentary 100W overloads will not cause failure Insulation Resistance All terminals maintain a minimum 10 Q to ground AC DC Difference Less than 5 ppm from 0 to 1 592 Hz Dimensions Weight Bench Top Formica Case Height 10 0 inches Width 8 10 inches Depth 12 25 inches Weight 10 5 Ibs net 12 Ibs shipping weight Oil Bath Stainless Steel Case Height 5 0 inches Width 3 5 inches Depth 7 0 inches Weight 4 0 Ibs net 6 0 Ibs shipping weight Temperature Coefficient Alpha temperature coefficient less than 0 1 ppm C at 23 C Beta 1 2 rate of change of temperature coeffic
154. meee 15061101 Pulse Head for CU cesactnee ee wees peers wens 67068101 Tunnel Diode Pulser AA5001 Distortion Analyzer AA5001 CCIR 0 008 AM502 eene AW1012 Control Panel Hinged Window 10 x 12 00a ee AW1418 Control Panel Hinged Window 14 x 18 0 AW1418S Control Panel Hinged Window 14 x 18 Stainless Steel AW1822 Control Panel Hinged Window 18 X22 cesare dow Seas AW1822S Control Panel Hinged Window 18 x 22 Stainless Steel AW2228 Control Panel Hinged Window 22 x 28 00 0s AW2228S Control Panel Hinged Window 22 x 28 Stainless Steel B9409 Calibrations amp Standards DC 40 GHz Reference Book CG5011 Programmable Calibration Generator CRT 2AF 0002 CRISE enc ceheetaesastcaw tenet os CRAP CRT 5R DBAZ ae ce a ee ee f Contact TEGAM Inc at 440 466 6100 for information BACK TO CONTENTS K 9 INDEX BY MODEL NUMBER DB62 11K 11 K ohm Decade HeSISIO due daba eed ene tns EY C 11 DB62 111K 111 K ohm Decade Resistor C 11 DB62 1M 1 M ohm Decade PICSISION ssh asa neu nest C 11 B62 11M 11 M ohm Decade PIGSISIOP uoo dbieunede eR ma pedis wed C 11 DB6B5A Lc xni RR d 9 DB877 12 M ohm Decade Resistor 2s arp xy soe ae EY
155. ments The DVM and Power Meter readings are then used in some simple calculations to determine the cal factor of the UUT at the selected frequency These calculations can be performed by the user or by entering the meter readings into the Microsoft Excel spreadsheet provided by TEGAM This spreadsheet contains the formulas necessary to calculate cal factor and is provided as a convenience for our customers Prices and specifications subject to change without notice BACK TO CONTENTS TEGAM YOUR GLOBAL SOURCE FOR TEST AND MEASUREMENT SOLUTIONS Model 1825 ECONOMICAL RF POWER Specifications Frequency Range SENSOR CALIBRATOR 10 MHz to 18 GHz Power Range 0 01 to 25 mW 20 to 14 dBm Substitution Bridge Accuracy 0 003 Nominal RF Impedance 50 Ohms VSWR lt 1 14 Power Linearity 0 196 from 1 to 10 mW Insertion Loss RF INPUT 6 dB nominal 9 5 dB max Individual calibrations traceable to NIST supplied at the following frequencies 10 to 100 MHz in 10 MHz increments 100 MHz to 2 GHz in 50 MHz increments 2 GHz to 4 GHz in 100 MHz increments 4 to 12 4 GHz in 200 MHz increments 12 75 to 18 GHz in 250 MHz increments Calibration Factor Accuracy 1 00 from 0 01 to 10 GHz 1 10 from 10 to 18 GHz Calibration Factor Drift 0 5946 per year Connectors SENSOR N type Female RF IN SMA Female VOLTMETER Binding Post standard 0 75 spa
156. mitter The HUMITRAN series provides a reliable accurate and low cost solution for monitoring relative humidity and temperature Solid state sensors supply excellent ta sensitivity fast response and long term RH TEMP TRANSMITTER RH TRANSMITTER stability Simple hookup and linearized Model RHT 20C or RHT 10V Model RH 20C or RH 10V A model RDP temperature duc orobe transmitter included output permit interfacing with most display or control devices AUTOMOTIVE MEDICAL FOOD PROCESSING Engine Test Cells Pill Coating Freeze Drying Emission Testing Operating Room Grain Silos Paint Spray Toxicology Baking Passenger Environment Testing Poultry Industry MANUFACTURING STORAGE ENVIRONMENTAL Plastics Food Heating Ventilating Printing Grain Air Conditioning RH TEMP CONTROLLER Painting Paper Computer Rooms Model CSP F1 CSP C1 Adhesives Tobacco Museums CSP F2 CSP C2 HIGH TEMP RH TEMP PROBE RH TEMP DUCT PROBE HUMIDITY CONTROLLER TRANSMITTER TRANSMITTER Model RHS 1 Model HTRH D or HTRH W Model RDP 20C or RDP 10V Setpoint Controller YOUR GLOBAL SOURCE FOR TEST BACK TO CONTENTS AND MEASUREMENT SOLUTIONS Prices and specifications subject to change without notice J 1 J 2 HUMIDITY CONTROLLERS AND TRANSMITTERS HUMITRAN CSP RH TEMP CONTROLLER e Included Probe may be Thousands of Feet Digital Display of Setpoints Deadbands from the Controller and Values Recorder Outputs 1 8 DIN Metal Enclosure
157. n R9 MI ny DZ DATA GRAPH 20 8 17 7 14 6 11 4 8 3 5 2 Attenuation dB 2 0 14 15 4 2 3 4 Ao 5200 8400 11600 14800 18000 Frequency MHz TEGAM ft YOUR GLOBAL SOURCE FOR TEST AND MEASUREMENT SOLUTIONS B 7 B 8 RF ATTENUATION MEASUREMENT this toolbar are representative of some of the commonly used menu functions such as program ICONS The CAMLab program has a horizontal toolbar that contains the program Icons this is always present at the top of the main window The icons in information Help Open Save Files and quick exiting from the program The CAMLab toolbar also contains program specific Icons as follows Graph calibration data plots calibration data in a graph window VM 7 mode configuration setup for configuring the VM 7 and signal source in a 30 MHz calibration System VM 7 8852 8853 mode configuration setup for configuring the VM 7 8852 and signal source for a 0 01 18 GHz calibration System 8850 operation Allows for the 8853 to be incorporated into the system for measure ments between 18 001 to 40 GHz VM 7 Mixer mode configuration setup for configuring the VM 7 user selected mixer and two signal sources to perform custom calibrations Auto measurement run mode allows the operator to set up and perform automatic measurements across a defined frequency range Single Step measurement run mode allows the operator to set up CA
158. ncludes all hardware tape and shrink tubing for the total replacement of 1 set of Kelvin Klips KK110 Kelvin Klip Leads with Ground This data sheet was current when it was produced However products are constantly being updated and improved Because of this some differences may occur between the descriptions herein and the current product Prices and specifications may be changed without notice YOUR GLOBAL SOURCE FOR TEST AND MEASUREMENT SOLUTIONS C 23 TEN TEGAM WAY GENEVA OHIO 44041 440 466 6100 FAX 440 466 6110 www tegam com e mail sales tegam com C 24 YOUR GLOBAL SOURCE FOR TEST AND MEASUREMENT SOLUTIONS TEMPERATURE CALIBRATORS THERMOMETERS Calibrators Feature High Performance Without High Price Save time save money and meet ISO 9000 with the price performance leader in temperature calibrators These meters simulate source measure and record 11 Thermocouple types plus RTD Thermistor and Ohms signals all in one unit They out perform the competition in the lab and on the factory floor with 0 2 accuracy and 0 1 resolution 0 01 ohms You also get full featured temperature measurement plus unmatched TEGAM quality all for half the competitors price Save Time These calibrators increase productivity They are faster and easier to use than any other calibrator With 10 memory locations for calibrator setpoints and a step function you can W a
159. nd series parallel configuration without introducing insulation leakage errors External shorting or paralleling bars are not necessary Each resistance section consists of precision wire wound resistors connected in series The reduced heat concentration of the series connection improves the thermal characteristics of a resistance element with an already low temperature coefficient BACK TO CONTENTS MEI IE 1050 YOUR GLOBAL SOURCE FOR TEST AND MEASUREMENT SOLUTIONS C 9 Model SR1050 HIGH RESISTANCE TRANSFER STANDARD Specifications Standard Values 1 and 1OMQ step Accuracy Transfer Limited only by short term repeatability of resistance values Typical repeatability 2 ppm Initial 25 ppm of nominal value matched within 10 ppm for 1MQ 30 ppm of nominal value matched within 10 ppm for 10M Q Long Term 50 ppm of nominal value Calibration 10ppm for IMQ 15 ppm for 1OMQ Calibration Conditions 23 C low power three terminal measurement Temperature Coefficient 5 ppm C matched within 5 ppm C Power Coefficient 0 05 ppm mW per resistor Maximum Power Rating IW step or 5W distributed over 10 steps or maximum voltage of 2 5kV where this value does not result in power excess of 1 W per resistor Breakdown Voltage 3 5kV peak between active terminals and case Leakage Resistance Greater than 10P 2 from terminals to case Calibration Data Initial cali
160. nd manual spare input connector included with 868 869 MODEL RANGE RESOLUTION ACCURACY 865 40 to 199 9 0 1 0 3 rdg 0 5 F 70 to 300 1 0 3 rdg 1 F 866 40 to 150 0 1 0 3 rdg 0 3 C 868 100 to 199 9 0 1 4 F 100 to 1100 1 oF 869 100 to 199 9 0 1 3 100 to 630 1 o 0 2 0 3 C he RP Re Re Re RP Re 1C REPEATABILITY 0 1 C 0 2 F typical DISPLAY 31 digit LCD 5 high DIMENSIONS 6 3 x 2 7 x 1 2 Net weight 7 5 oz ACCESSORIES AVAILABLE 8660 tilt stand belt clip 8668 vinyl case This data sheet was current when it was produced However products are constantly being updated and improved Because of this some differences may occur between the descriptions herein and the current product Prices and specifications may be changed without notice YOUR GLOBAL SOURCE FOR TEST BACK TO CONTENTS AND MEASUREMENT SOLUTIONS Thermistor Probes RS AND PROBES Sensor Probe Ideal for biological and geophysical testing of gases liquids and subsoils This rugged 5 ft long probe has stranded 22AWG Teflon insulated wire Sheath 304 SS Max temp 300 F 150 C Time constant 6 sec Accuracy 0 2 C from 0 C to 70 C MODEL 8662 ORDERING INFORMATION General Purpose Probe For immersion in liquids and gases 316 SS sheath TPR coil cord 1 ft ext 3 ft au umi Max temp 300 F 150 C Time constant 3 sec Accuracy t 0 2 C ORDERING INFORMATION Penet
161. nector Transition Time lt 150ns Tested with square wave filter off 1OVp p 50 2 termination Creation Tools Internal Spectral Purity THD Noise 86 dB typical Waveform Editing Point Mode Line Mode Vertex Tested with 80kHz measurement bandwidth 2MHz clock 2 kHz Mode Insert Function Sum sine wave 1000 points filter on full amplitude 50Q termination Function Dump Function Digital Amplitude and Offset Amplitude Offset Smooth Range Resolution Accuracy Copy Paste Waveform Math 1 00 to 10V 10mV 1 of setting 20mV _ A B A B AxB si00mVto000mV uv 3 of setting 5mV Pointing Device Front panel keys and knob 10mV to 99 9mV 100uV 596 of setting ImV Software WaveWorks Pro Optional Note 50 2 source impedance measured at open circuit tested with l kHz Stored Se ttings sinewave plus DC offset Setups 20 instrument settings Analog Filter C User selectable 700kHz 7th order 40kHz 3rd order DONE EET TAE Operational Modes RS 232C 19 2k Baud max Continuous Triggered Gated Burst 1 to 1 048 575 E a a Toggled Hold RTS Return to start General Outputs Temperature Range 73 4 F 5 4 F 23 C 3 C Main Output Front panel 50Q impedance for specified accuracy Sync Outputs SYNC 1 SYNC 4 All fully Operates 32 F to 122 F 0 C to 50 C programmable addresses amp widths Storage 4 F to 140 F 20 C to 60 C 9 99 1 SYNC 1 OUT Front panel TTL 50Q
162. ng WaveWorks FFT and IFFT routines An instrument interface is also included to allow complete PC operation of your TEGAM arbitrary waveform generator controls via RS 232C or GPIB Interface Sequence Programming TEGAM s arbitrary waveform generators are unique compared to competitor s waveform generators in that they have sequencing capabilities Sequencing expands an arbitrary waveform generators memory by linking and looping various waveform segments to produce a continuous waveform output WaveWorks Pro IM can be used with any of TEGAM s arbitrary waveform generators to easily create custom waveform sequences YOUR GLOBAL SOURCE FOR TEST AND MEASUREMENT SOLUTIONS E 15 WaveWorks Pro WAVEFORM CREATION SOFTWARE Standard Waveforms WaveWorks offers 33 standard waveforms that include parameter templates to create custom waveforms for your application The following standard waveform templates are available Sine Cosine Square Triangle VHR Pulse Hanning SinX X Y Burst Sweep Digital Noise Analog Noise Math Transfer Function DC Pulse 2 FIR LPF BFSK Comb Step Sweep 20 transfer functions including integration and differentiation are available to process waveform data Null Linear Section Mirror Square Root Polynomial Integration Differentiation Q Phase Math Operator Complex waveforms are readily created by use any of the 13 different math operators Addition Subtraction Multiplicati
163. nput thermocouple thermometers TEGAM s 847 simulates K J or T thermocouple types Fine and coarse adjustment pots let you quickly dial in 350 to 2500 F with a resolution of 0 1 F or C The 847 is cold junction compensated to eliminate errors caused by ambient temperature changes and has an accuracy of 0 3 With an optional exten sion cable the 847 becomes a bench unit complete with rubber feet and built in tilt feature NIST Traceable Statement of Calibration provided upon request Low battery indicated on reference thermometer One year warranty SPECIFICATIONS ACCESSORIES SUPPLIED 840 401 type K TC cable male sub miniature connec tor to spade lugs 9V battery instructions ACCURACY 0 396 1 C accuracy of indicating thermometer RESOLUTION 0 1 C F THERMOCOUPLES RANGE TYPE K IRER DRES gE 328 to 2502 346 to 1400 328 to 752 C 200 to 1372 210 to 760 200 to 400 DIMENSIONS 5 x 2 8 x 1 5 Net weight 1 Ib ACCESSORIES AVAILABLE 8668 vinyl carrying case 80141 type K TC extension cable ORDERING INFORMATION MODEL 847 Multiprobe Switchbox TEGAM s 8000 Series switchbox enables you to read six probes in any sequence on your K J or T thermometer Compatible with virtually every bench and handheld digital thermometer TEGAM multi probe switchboxes plug directly into any handheld thermometers including single and multiple input units TEGAM switchboxes can also interface multiple prob
164. nstruments including additional 2414B Prices and specifications subject to change without notice BACK TO CONTENTS units to be hardware triggered by waveform events Because each output is fully programmable multiple sync pulses can be defined at any width or location within waveform memory Hardware sync is more precise than software sync enhances system performance and reduces development time TEGAM is the only manufacturer that offers programmable synchronous outputs Extensive User Tools Expand the 2414B s memory up to 30 000 times with the optional sequence generator Each sequence program can have up to 4 096 steps which can link to any of the 2414B s 1 000 user defined waveforms Each waveform may be looped up to one million times per step Up to one hundred unique sequence programs may be stored in the sequencer s non volatile memory WaveWorks Pro M software optional is a total software solution for importing exporting creation and editing waveform data in up to seven formats including the common ASCII formats CSV and PRN See the WaveWorks Pro data sheet for more information Facilitates the Design of Complex Test Systems The RS 232C and optional IEEE 488 2 offer direct easy programming capability The 2414B has numerous triggering and timing inputs outputs for precise multi phase operation of several instruments Up to four slave arbs may be triggered by a single master 2414B
165. o 2018 01 TEGAM TEN TEGAM WAY GENEVA OHIO 44041 YOUR GLOBAL SOURCE FOR TEST 440 466 6100 FAX 440 466 6110 AND MEASUREMENT SOLUTIONS www tegam com e mail sales tegam com Model 1806 Therm istor power standards e Power meters bias either 100 or 200 ohm mounts Fault LED indicator illuminates when loop balance is prevented One year warranty Optional A2LA Accredited Calibrations Prices and specifications subject to change without notice MEASUREMENT PRODUCTS Dual Type IV Power Meter 0 01 mW to 30 mW The Model 1806 Dual Type IV Power Meter is designed for use with thermistor elements mounts to measure high frequency or microwave power It also functions as a standard for the calibration of bolometer mounts detectors RF voltmeters and for precision insertion loss measurements when used as part of the TEGAM System IIA Automatic Power Meter Calibration System The exclusive use of 100 dc substituted power eliminates the effect of ac components on the bridge circuit which has been shown to introduce a substantial error in the substituted power due to the short term time constant of some bolometer elements Substituted dc power levels ranging from 0 01 mW to 30 mW can be measured to within 0 003 which also makes this an ideal instrument for insertion loss measurements BACK TO CONTENTS Regardless of the application all measurements can be made directly traceable to prima
166. o initiate RTS mode 0 02 to 10 seconds Front panel button Rear panel BNC connector Creation Tools Internal Waveform Editing Pointing Device Software Stored Settings Setups Computer Interface RS 232C GPIB General Temperature Range Operates Storage Dimensions Weight Power Point Mode Line Mode Vertex Mode Insert Function Sum Function Dump Function Digital Amplitude Offset Smooth Copy Paste Waveform Math A B A B AxB Front panel keys and knob WaveWorks Pro IM Optional 20 instrument settings 19 2k Baud max IEEE Std 488 2 1987 Optional 73 4 F 5 4 F 23 C 3 C for specified accuracy 32 F to 122 F 0 C to 50 C 4 F to 140 F 20 C to 60 C 10 14 X 4 53 X 11 81 25 8 X 11 5 X 30cm WxHxD 11 Ibs 5 0kg 55VA 45W max 100 120 220 240VAC 4596 10 48 to 63Hz This data sheet was current when it was produced However products are constantly being updated and improved Because of this some differences may occur between the descriptions herein and the current product Prices and specifications may be changed without notice TEGAM YOUR GLOBAL SOURCE FOR TEST AND MEASUREMENT SOLUTIONS www tegam com BACK TO CONTENTS TEN TEGAM WAY GENEVA OHIO 44041 440 466 6100 FAX 440 466 6110 e e mail sales tegam com Model 2416A e 64k Point Waveform Memory Sequence Generator Included Direct Frequency Setting e St
167. o risk trial YOUR GLOBAL SOURCE FOR TEST AND MEASUREMENT SOLUTIONS Model 2714A LOW COST AWG WITH EXTENDED MEMORY Specifications Output Waveforms Up to 100 High definition custom waveforms Sine Square Triangle Ramp DC Exponential Haversine Pulse Gaussian Sin x x Sinc Waveform Storage 100 Waveforms Resolution Horizontal Points 131 036 max Vertical Points 12 bits 4 096 2 048 to 2 047 0 1Hz to 20MHz 10s to 50ns 4 digit resolution 50ppm accuracy Transition Time 20ns Tested with square wave filter off 10Vp p 50 2 termination Spectral Purity THD Noise 65 dB typical Tested with 80kHz measurement bandwidth 20MHz clock 20 kHz sine wave 1000 points filter on full amplitude 50 2 termination Amplitude and Offset Range Resolution 1 00 to 10V 10mV 100mV to 999mV ImV 3 of setting 5mV 10mV to 99 9mV 100uV 5 of setting ImV Note 50Q source impedance measured at open circuit tested with kHz Sample Rate Accuracy 1 of setting 20mV sinewave plus DC offset Analog Filter User selectable 7MHz 7th order Sequence Generator Optional Waveform Transient free Loop and Link Repetitions Loop 1 048 575 times Link 100 waveforms Program 100 Steps total File 10 Sequences Operational Modes Continuous Output runs continously between selected memory address locations Triggered Output at start point until triggered then
168. occur between the descriptions herein and the current product Prices and specifications may be changed without notice Certificate no 2018 01 TEGAM YOUR GLOBAL SOURCE FOR TEST AND MEASUREMENT SOLUTIONS BACK TO CONTENTS TEN TEGAM WAY GENEVA OHIO 44041 440 466 6100 FAX 440 466 6110 www tegam com e mail sales tegam com Model F1125 M11 Thermistor Standards are temperature controlled 0 01 to 25 mW dynamic range Primary and Working Transfer Standard configurations e Rack mount kit available Optional A2LA Accredited calibrations MEASUREMENT PRODUCTS Coaxial RF Power Transfer Standards TEGAM Temperature Stabilized Coaxial RF Power Transfer Standards enable the precise measurement of microwave power in the 100 kHz to 4 2 GHz frequency range These units are extremely rugged highly accurate and stable with time and temperature They are ideal for use as standards for the transfer of calibration factors to other RF standards and power sensors Units are supplied with ANSI NCSL Z540 1 1994 NIST traceable calibration data A2LA Accredited Calibrations are optional These models are designed for use with dc self balancing bridges such as the TEGAM Model 1806 and 1804 or with controllers such as the TEGAM Model 1805B System configurations employing instruments of this extreme accuracy typically achieve calibration factor transfer results normally found only in
169. om everyday bangs and bumps in your toolbox This boot is designed to protect your calibrator while not interfering with plugging in cables using the tilt stand or the AC adaptor Also included is a removable belt clip ORDERING INFORMATION MODEL 8204 EXTENSION CABLES Not shown MODEL NUMBER BY TC TYPE K INSULATION LENGTH 80141 PVC 3 This data sheet was current when it was produced However products are constantly being updated and improved Because of this some differences may occur between the descriptions herein and the current product BACK TO CONTENTS Prices and specifications may be changed without notice TEN TEGAM WAY GENEVA OHIO 44041 440 466 6100 FAX 440 466 6110 www tegam com e mail sales tegam com YOUR GLOBAL SOURCE FOR TEST AND MEASUREMENT SOLUTIONS Model 2411B e 20 Standard Wav 64k Waveform Memory Stores 100 Custom Waveforms e Summing Input e RS 232C Options 1000 Step Sequence Generator WaveWorks Pro Waveform Creation Software GPIB Communications Rack Mount Kit Signal Integrity Waveforms will always be consistent and repeatable because the 2411B is a true arb It uses the raster scan technique with sequential addressing of waveform memory and a variable sample clock rate to adjust the output frequency Other generators use phase accumulator based addressing which can skip or repeat waveform data points The typical THD total harmonic distortion plu
170. on QAM AM PM FM Waveform Analysis Synthesis Frequency Domain FFT and IFFT Harmonics up to 500th harmonic Displays graphic and tabulation Entry tabulation Units Sin Cos Ampl Sin Ampl Phase Cos Ampl Phase Sin dB Phase Cos dB Phase Other features random phase entry Time Domain Digital Pattern Display Edit Computer Requirements Operating Systems PC Requirements Interfaces graphic mouse Windows 95 98 XP and 2000 Operating Systems 486DX or better processor w 4MB RAM Serial COM Port RS 232C up to 19 2k Baud DC Cut Normalize Rotate I Q Swap GPIB National Instruments AT GPIB card IEEE standard 488 2 1987 WaveWorks Pro is compatible with the following TEGAM arbitrary waveform generators 2411A 2411 B 2414A 2414B 2711A 2714B 2416A This data sheet was current when it was produced However products are constantly being updated and improved Because of this some differences may occur between the descriptions herein and the current product Prices and specifications may be changed without notice TEGAM YOUR GLOBAL SOURCE FOR TEST AND MEASUREMENT SOLUTIONS E 16 BACK TO CONTENTS TEN TEGAM WAY GENEVA OHIO 44041 440 466 6100 FAX 440 466 6110 www tegam com e mail sales tegam com Model 3525 Compact Size Easy to Use Manual or Automated Operation Better than Agilent at half the price e 99 Storable Panel Settings Built in Comparator F
171. or more information on the 1750 or to schedule a FREE 30 Day Evaluation This data sheet was current when it was produced However products are constantly being updated and improved Because of this some differences may occur between the descriptions herein and the current product Prices and specifications may be changed without notice BACK TO CONTENTS TEN TEGAM WAY GENEVA OHIO 44041 440 466 6100 FAX 440 466 6110 www tegam com e mail sales tegam com YOUR GLOBAL SOURCE FOR TEST AND MEASUREMENT SOLUTIONS ELECTRICAL SAFETY METERS Voltmeters Combine Safety TEGAM TEGAM with Productivity These meters automatically test AC and DC volts null induced voltages withstand 2 500 volts and are virtually foolproof Routine power measurement is never routine TEGAM s Voltmeters prevent lost time accidents Whether you re measuring voltage locking out equipment testing or troubleshooting TEGAM s voltmeters are the safest you can buy All models have the voltage measuring capabilities of a DMM while fully protecting the user and the instrument against operator errors There is only one control an ON OFF switch Since there are no functions or ranges to select the user can t select the wrong one Testing is fast and easy because the unit automatically checks for AC and DC voltages When the easy to read display says 000 the line is clear absolutely The 36 test leads are permanently secured
172. ost increases This program saves you downtime and money The program eliminates potentially critical delays caused by evaluation quotation and approval procedures Priority service scheduling is included as part of this plan Your instrument goes to the head of the line as soon as it arrives at TEGAM TO ORDER EW3 XXXX Extended Warranty Plan WARRANTY FEATURES Repair and recalibration by trained factory technicians if your instrument stops working or goes out of calibration prematurely excluding abuse or misuse This includes Isolation and correction of any faults Repair Replacement of defective components Functionality Verification A new calibration if required All Parts and Labor are included at no charge Additional Service Any new Software and or Firmware upgrades will be installed Any new Safety and or reliability enhancements will be installed Available with qualified New Product Purchases XXXX is the model number of the instrument warranted This program offers three full years of repair starting from the date of shipment This extends a standard one year warranty to three years EWS XXXX XXXX 1s the model number of the instrument warranted This program offers five full years of repair starting from the date of shipment This extends a standard one year warranty to five years BACK TO CONTENTS This data sheet was current when it was produced However products are
173. ours 2 hours Weight 6 27 lbs 2 84 kg 2 875 lbs 1 3 kg Physical Dimensions Height Width Depth 3 5 in 88 9 mm 8 5 in 215 9 mm 15 4 in 390 7 mm 2 88 in 73 15 mm 4 00 in 101 6 mm 7 45 in 189 23 mm This data sheet was current when it was produced However products are constantly being updated and improved Because of this some differences may occur between the descriptions herein and the current product Prices and specifications may be changed without notice Certificate no 2018 01 Ue YOUR GLOBAL SOURCE FOR TEST AND MEASUHEMENT SOLUTIONS BACK TO CONTENTS TEN TEGAM WAY GENEVA OHIO 44041 440 466 6100 FAX 440 466 6110 www tegam com e mail sales tegam com Model 1107 8 i ae Treaue e Standards are directly traceable to NIST e Thermistor Standards are temperature controlled e 0 01 to 10 mW dynamic range Primary and Working Transfer Standard configurations MEASUREMENT PRODUCTS Waveguide RF Power Transfer Standard TEGAM Temperature Stabilized Waveguide RF Power Transfer Standards enable the precise measurement of microwave power in the 26 5 to 40 GHz frequency range These units are extremely rugged highly accurate and stable with time and temperature They are ideal for use as standards for the transfer of calibration factors to other RF standards and power sensors Units are supplied with ANSI NCSL Z540 1 1994 NIST traceable cal
174. r direct recall and editing from the front panel or standard GPIB interface Extensive User Tools The 2416A s memory capabilities are extended by use of its internal sequence generator Each sequence program can have up to 99 steps which can link to any of the 2416A s 99 user defined waveforms Each waveform may be looped up to 32 767 times per step Up to nine unique sequence programs may be stored in the sequencer s non volatile memory WaveWorks Pro software optional is a total software solution for importing exporting creation and editing waveform data in up to seven formats including the common ASCII formats CSV and PRN See the WaveWorks Pro data sheet for more information Warranty The Model 2416A is backed by a full l year warranty and TEGAM s 30 day no risk trial TELLITE E z YOUR GLOBAL SOURCE FOR TEST AND MEASUREMENT SOLUTIONS E 6 Model 2416A HIGH SPEED AWG Output Characteristics Amplitude into 50Q load Range Resolution Accuracy 1 00 to 9 99Vp p 10mV 2 20mV 100mV to 999mVp p ImV 3 4mV 10mV to 99 9mVp p 100uV 4 2mV Offset into 50Q load Range Window Accuracy 0V to 4 50V 5 0V 2 1 ampl 20mV 0V to 450mV 500mV 3 1 ampl 5mV 0V to 45 0mV 50 0mV 4 1 ampl 2mV Filters SOMHz 7 pole elliptic 25MHz 7 pole elliptic 20MHz 7 pole Gaussian Squarewave Pulse Rise fall time 5ns 1096 to 9096 of amplitude Aberration lt 5 Synchronous Output Front
175. rary addition of a jumper on internal PC board NOTES 1 Fast Mode available on range and full scale voltage combinations shown 10 msec Delayed Mode available on combinations shown D Delayed Mode Measurement Times 2x Line Period Programmed Delay 1 7 ms Processing Time e g 60 Hz line frequency and 10 ms delay Time 55 0 ms Delays are programmable from 1 ms to 250 ms in ms increments TRIGGER IN TIME TO FIRST READING READING DONE 2 msec TEGAM YOUR GLOBAL SOURCE FOR TEST AND MEASUREMENT SOLUTIONS G 3 G 4 Model 1750 HIGH SPEED MICRO OHMMETER Accessories 17501 Kelvin Klips allow you to make solid four terminal connections to leaded components This set is provided as a standard accessory with the 1750 and is hand measurement particularly useful for testing resistors Four terminal techniques allow precision measurements by avoiding the effects of lead resistance Gold plated hardened beryllium copper jaws ensure low contact resistance low thermal emf to copper high corrosion resistance and long life 17502 Spade Lug Adapter is an optional cable set for the 1750 Instead of clips it has spade lugs for connection to binding posts and peripheral equipment 17503 Sorting Fixture holds components for test while providing four terminal connection Its holding clips rotate 90 degrees to accommodate axial and radial leaded
176. ration Probe Sharp pointed tip for insertion into semi soft materials such as meat and cheeses Extra heavy duty coil cord expands and retracts thousands of times without n 3 4 eet breaking M 304 SS sheath 316 SS tip pu TPR coil cord 11 ft ext 5 ft yg Max Temp 300 F 150 C SAE CMAC Time constant 3 sec MODEL 82814 Accuracy t 0 2 C from 0 C to 70 C Surface Probe For fast measurements on flat surfaces 304 SS sheath TPR coil cord 1 ft ext 3 ft Max temp 300 F 150 C Time constant 5 sec Accuracy 0 2 C ORDERING INFORMATION from 0 C to 70 C MODEL 8665 Air Gas Probe For measurement of air and gas streams incubators etc Exposed sensing element protected by perforated 3 3 4 shield Y ia g q 304 SS sheath TPR coil cord 1 ft ext 3 ft AA Max temp 300 F 150 C int Time constant 10 sec ORDERING INFORMATION Accuracy 0 2 C MODEL 8666 from 0 C to 70 C Note All TEGAM thermistor probes are supplied with YSI Series 400 compatible phone jacks This data sheet was current when it was produced However products are constantly being updated and improved Because of this some differences may occur between the descriptions herein and the current product Prices and specifications may be changed without notice 8 BACK TO CONTENTS TEGAM TEN TEGAM WAY GENEVA OHIO 44041 l 6 YOUR GLOBAL SOURCE FOR TEST 440 466 6100 FAX 440 46
177. rator Thermometer C amp co F K J T amp E Ohms 100 ohms RTD amp Thermistor D 1 855 Calibrator Thermometer C amp e F Multi T Cs Ohms 100 ohm amp 1 000 ohm RTD D 1 865 Thermistor Thermometer 866 Thermistor Thermometer me Pm l 5 868 Platinum RTD Thermometer CP reee as ieee eee l 5 869 Platinum RTD Thermometer l 5 871A Thermocouple Thermometer Dual Input w Analog Output Type K I 3 872A Thermocouple Thermometer Dual Input w Analog Output Type J I 3 874C Economical Thermocouple Thermometer C Type K I 3 874F Economical Thermocouple Thermometer F Type K I 3 875F Economical Thermocouple Thermometer F Type T 7 ric PET eek me BDORAJB 123 acne ae dor o anew 9 1104 Utility Lineman Carrying Case Leather H 2 1107 7 RF Waveguide Power Standard 18 26 5 GHz 1107 8 RF Waveguide Power Standard 26 5 40 GHz A 13 1204 Utility Lineman Carrying Case Cordura H 2 1304 Carrying Case amp Stand for 871A amp 872A 9 Contact TEGAM Inc at 440 466 6100 for information BACK TO CONTENTS K 7 K 8 INDEX BY MODEL NUMBER 1412B Limits Comparator Accessory lor 252 253 254 i i olere 1583 3 GPIB IEEE 488 Cable 1 Meter Long 2e 1583 6 GPIB IEEE 488 Cable 2 Meters Long err Rs 1583 9 G
178. reation software is also provided at no additional charge Three multi phase modes are available to synchronize multiple units for phase sensitive applications Function Generator Operation Direct front panel access to 10 standard waveforms with adjustable parameters provides function generator operation for basic lab use For test applications where custom signals are required up to 100 user defined waveforms may be stored in waveform memory The waveforms may be recalled via the 2714A s front panel or the included WaveWorks Jr wave creation software Effective User Tools Leverage the 2714A s memory capabilities by adding an optional sequence generator Each sequence program can have up to 100 steps which can link to any of the 2714A s 100 user defined waveforms Each waveform may be looped over one million times per step Ten unique programs may be stored in the sequencer s non volatile memory to produce transient free output waveforms WaveWorks Jr is a complete software solution for importing exporting creating and editing waveform data in the common ASCII formats CSV and PRN Windows M compatible it allows full programming access to both the instrument and the sequence generator WaveWorks Pro advanced wave creation software is available as an upgrade See the WaveWorks Pro data sheet for more details Warranty The Model 2714A is backed by a full 3 year warranty and TEGAM s 30 day n
179. representative For more information visit of these efforts and is yet another visible i step in our continual quality www tegam com improvement process TEGAM Inc has always sought a method that would accurately reflect our commitment to a quality system that is periodically assessed by our technically competent peers and that offers demonstrable nationally recognized evidence of continual compliance A2LA has provided the opportunity National Association for Proficiency Testing A Non Profit Organization Dedicated to Excellence in Metrology amp Test Measurement Tegam Inc IS A MEMBER IN GOOD STANDING OF THE NATIONAL ASSOCIATION FOR PROFICIENCY TESTING peiorem er ape Geneva OH as an Active Member of the National Association for NAPT promotes the ideals of measurement quality demonstrates vndc cmn eei e Calibration Certificates for accreditation not only to TEGAM Inc but also other calibration laboratories across the nation TEGAM Inc is now able to provide A2LA Accredited calibrations within our Scope of Accreditation as described in our Certificate Number 2018 01 that many of our customers have been seeking We look forward to serving you now and in the future National Association for Proficiency Testing The National Association for Proficiency Testing NAPT is a third party non profit organization dedicated to assisting the metrology and testing community in meeting the growing deman
180. rminating thermistor Primary Transfer Standard It is designed to be calibrated directly by a national standards agency such as NIST The M1110 is used for the calibration of feedthrough devices such as bolometer mount coupler and bolometer mount splitter RF Standards and in other applications requiring direct measurement of RF power Both Models feature a Type N RF connector Bias connectors are binding posts with standard 0 75 spacing for banana plugs The connector for the internal heater is compatible with the heater control circuit on TEGAM Models 1805B 1806 and 1820 TEGAM YOUR GLOBAL SOURCE FOR TEST AND MEASUREMENT SOLUTIONS A 6 Model F1109 M1110 COAXIAL RF Specifications Frequency Range POWER TRANSFER STANDARDS F1109 10 MHz to 18 GHz M1110 10 MHz to 18 GHz Power Range F1109H 0 01 to 25 mW 20 to 14 dBm 0 1 to 250 mW 10 to 24 dBm 0 01 to 25 mW 20 to 14 dBm Nominal Impedance 50 Ohms 50 Ohms Max VSWR 1 06 from 0 01 to 6 GHz 1 10 from 6 to 15 GHz 1 14 from 15 to 18 GHz 1 50 from 10 to 20 MHz 1 40 from 20 to 50 MHz 1 30 from 50 to 100 MHz 1 20 from 0 1 to 4 GHz 1 30 from 4 to 8 GHz 1 40 from 8 to 18 GHz Power Linearity F1109H 0 1920 from 1 to 10 mW lt 0 1 from 10 to 100 mW lt 0 1 from 1 to 10 mW Insertion Loss F1109H 6 dB 8 5 dB max 16 dB 18 5 dB max 1 dB max Individual calibrations traceable to
181. robe Holder Test instrument fits snugly inside holder providing a tilt stand belt clip and probe holder Detachable temperature probe holder snaps on or off Tough ABS material provides toolbox durability 874F THERMOMETE R Ib ae ORDER 8660 WITH THESE TEGAM UNITS TEGAM TYPE FITS MODEL NUMBERS MODEL 8660 Thermometers 865 866 868 869 874 Padded Case Foam padded case can be hung from your work belt Case includes pocket for storing leads probes etc ORDER 8668 WITH THESE TEGAM UNITS 8668 CASE TYPE Thermometers MODEL NUMBERS 819 820 821 865 866 868 869 87 1 A 872A 874 This data sheet was current when it was produced However products are constantly being updated and improved Because of this some differences may occur between the descriptions herein and the current product Prices and specifications may be changed without notice BACK TO CONTENTS TEGAM TEN TEGAM WAY GENEVA OHIO 44041 YOUR GLOBAL SOURCE FOR TEST 440 466 6100 FAX 440 466 6110 AND MEASUREMENT SOLUTIONS www tegam com e mail sales tegam com DIGITAL THERMOMETERS AND PROBES CHANNEL SELECT COARSE ADUST O FINE General Purpose Calibrator TEGAM s 847 using virtually any digital ther mometer as reference accurately and inexpensively calibrates handheld thermome ters panel meters and thermocouple readout devices The 847 is compatible with bench or handheld single or multiple i
182. rom 1 to 10 mW Insertion Loss 6 dB 8 5 dB max 1 dB max Individual calibrations traceable to NIST supplied at the following frequencies 100 200 455 kHz 1 1 25 3 5 MHZ 10 to 100 MHz in 10 MHz steps 0 1 to 2 GHz in 50 MHz steps 2 GHz to 4 GHz in 100 MHz steps 4 2 GHz 100 200 455 kHz 1 1 25 3 5 MHz 10 to 100 MHz in 10 MHz steps 0 1 to 2 GHz in 50 MHz steps 2 GHz to 4 GHz in 100 MHz steps 4 2 GHz Calibration Factor Accuracy Calibration Factor Drift 0 80 from 0 01 to 10 MHz 0 90 from 10 to 4200 MHz 0 5946 per year 0 80 from 0 01 to 10 MHz 0 90 from 10 to 4200 MHz 0 596 per year Thermistor DC Bias Power Thermistor Resistance at Bias 30 0 7 mW 200 Ohms 30 0 7 mW 200 Ohms Thermistor Power Sensitivity Approximately 13 Ohms mW Approximately 13 Ohms mW Temperature Operating Storage 12 to 40 C 4 54 to 104 F 55 to 75 C 67 to 167 F 12 to 40 C 454 to 104 F 55 to 75 C 67 to 167 F Warm up time 2 hours 2 hours Weight 5 5 Ibs 2 5 kg 2 875 Ibs 1 3 kg Physical Dimensions Height Width Depth 3 5 in 88 9 mm 8 5 in 215 9 mm 15 4 in 390 7 mm 2 88 in 73 15 mm 4 00 in 101 6 mm 7 45 in 189 23 mm This data sheet was current when it was produced However products are constantly being updated and improved Because of this some differences may occur betw
183. ry voltage and resistance standards The 1806 contains two Type IV Power Meters and two built in temperature controllers for use with all TEGAM RF Power Transfer Standards refer to applicable data sheets for mount specifications The power meters are designed to bias either 100 or 200 ohm mounts Therefore they are compatible with Agilent HP 478A 486A and 8478A thermistor mounts when used with cable P N 138 652 Operating resistance for each power meter is selected by a front panel switch Each power meter has a bolometer current meter and fault LED indicator which illuminates under any condition preventing loop balance Terminals are provided for an external DVM positive and negative bolometer and voltage sense YOUR GLOBAL SOURCE FOR TEST AND MEASUREMENT SOLUTIONS A 19 Model 1806 DUAL TYPE IV POWER METER Specifications Power Range 0 01 mW to 30 mW Substitution Bridge Accuracy 0 003 Temperature Range Operating Storage 10 to 40 C 425 to 104 F 40 to 75 C 67 to 167 F Temperature Controller Bias Power Temperature Sensitivity Ambient Temperature Dynamic Range Mount Warm Up Time Internal Temperature Loop Gain Open Loop Frequency Response Warm Up Drive saturated Indicator 2 uW C per hour 12 C to 40 C 454 to 104 F 2 hours nominal 60 C 140 F nominal 80 dB minimum 0 1 Hz 8 10 V 200 mA minimum Voltmeter Connectors Binding
184. s 3 1 operating environment The major improvement over other DOS based and HTB programs is that this software provides all the CAMLab features found in other windows programs such as point and click user operation dialog boxes for easy instrumentation setup enhanced measurement data collection online help and the ability to generate and printout measurement data and graphs from almost any printer Refer to the CAMLab data sheet for more information This data sheet was current when it was produced However products are constantly being updated and improved Because of this some differences may occur between the descriptions herein and the current product Prices and specifications may be changed without notice Certificate no 2018 01 TEGAM YOUR GLOBAL SOURCE FOR TEST AND MEASUREMENT SOLUTIONS BACK TO CONTENTS TEN TEGAM WAY GENEVA OHIO 44041 440 466 6100 FAX 440 466 6110 www tegam com e mail sales tegam com Model 8852 e For use with Model VM 7 Advanced 30 MHz Receiver e Converts 0 01 to 18 GHz signals to a 30 MHz signal e Rack mount kit available Optional A2LA Accredited calibrations Prices and specifications subject to change without notice SUREMENT Frequency Converter 0 01 to 18 GHz Extends Your VM 7 Capabilities to 18 GHz The Frequency Converter Model 8852 is a device that is intended for use with the TEGAM Model VM 7 Attenuator and Signal Calibrator over th
185. s Model PC101 Parallel Compensation Network Used with a pair of SB103 shorting bars for the four terminal parallel connection of ten low value resistors in the Model SR1010 and SR1030 Resistance Transfer Standards PC101 Parallel Network Model SPC102 Series Parallel Compensation Network The Model SPC Series Parallel Compensation Network is used with a pair of the Model SB103 Shorting Bars for the four terminal series parallel connection of nine low value 7 resistors in the Model SR1010 and SR1030 Resistance Transfer Standards SPC102 Series Parallel Network SB103 Shorting Bars The Model SB103 may be used with either the PC101 or SPC102 Networks to create a series or series parallel combination of the low value resistors found in the SR1010 and SR1030 Resistance Transfer Standards Two shorting bars are included in a set SB103 Shorting Bars Model KK110 Kelvin Klip Leads with Ground Kelvin Klip assemblies are true four terminal connections that allow precise measurement by minimizing the affects of lead resistance Kelvin Klips are particularly useful connecting Transfer Standards to the unit being verified or calibrated The gold plated beryllium copper KK110 Kelvin Klip Leads jaws and the gold plated phosphor bronze spade lugs ensure low contact resistance low thermal emf to copper high corrosion resistance and a long life The assembly includes a 3 ft 9144 m shielded cable KK100 Kelvin Klip Rebuild Kit I
186. s noise of the 2411B is 86 dB making it ideal for applications requiring wide dynamic range signals GENERATORS 16 Bit True AWG Comprehensive Features The 2411B_ has outstanding performance offering 16 bit vertical resolution and over 64k of horizontal memory Standard or arbitrary waveforms are created through the front panel or optional WaveWorks Pro Msoftware The adjustable sample clock ranges from 0 1S s to 2MS s The 2411B s superior fidelity and wide dynamic range make it ideal for applications involving high precision low voltage or signal amplification Some applications include micro miniature machine stimulation MEMS sensor simulations sonar automatic airbag triggering multi tone audio signals cardiac and respiratory device testing Function Generator Simplicity Keypad access to 20 standard waveforms with adjustable parameters provides function generator simplicity for general lab applications For custom signal applications up to 100 unique waveforms may be defined and stored in waveform memory using the keypad or optional WaveWorks Pro software All programmed waveforms are available for recall and editing from the front panel RS 232C or GPIB optional interfaces Programmable Synchronous Outputs Each 2411B is equipped with four independently controlled synchronous outputs Prices and specifications subject to change without notice BACK TO CONTENTS Sync outputs allow externa
187. s other TEGAM test The 1827 is not a microprocessor controlled instrument instruments Prices and specifications subject to change without notice BACK TO CONTENTS but it is simple to operate Since measurements are taken with an external DVM the 1827 could be integrated into an automated workstation The Model 1827 s built in Thermistor RF Power Standard is controlled internally temperature so changes in ambient temperature will not affect power measurements The Type IV Bridge Circuitry detects RF power by using the DC power substitution method DC power levels can be measured to within 0 003 The Model 1827 has a wider frequency range than any commercially available power sensor calibrator Because of this wide frequency range two signal sources may be required The 1827 s two RF Inputs are designed so that the user can change signal sources just by flipping a switch This instrument is simple to operate To calibrate a power sensor the operator connects the output from the customer supplied RF signal generator to the one of the RF Inputs of the 1827 Then the and input of the customer supplied voltmeter is connected to the red and black binding posts on the 1827 The operator then connects the UUT to a customer supplied compatible power meter and to the SENSOR port of the 1827 Measurements can now be taken The DVM and Power Meter readings are then used to calculate the cal factor of the UUT at
188. sed of some of the industry s finest quality components for making RF and Microwave measurements Included are a selection of masking attenuators a power divider a type N adapter and termination and interconnect cables all in a wooden storage case The 8850 includes one 187 4001 187 4003 SWR Measurement Accessory Kit no photo This kit provides all the necessary items to perform SWR Return Loss measurements from 50MHz 18GHz The kit includes SWR bridges terminations adaptors and opens to perform SWR measurements on devices with SMA Type N or GPC 7 connectors The kit includes two wooden storage cases 187 1007 Rack Mount Kit no photo Rack Mount Kit for the VM7 ears only 187 1020 000 Maintenance Extender Card VM7 no photo Used to access digital boards for repair and verification 187 1021 000 Maintenance Extender Card VM no photo Used to access analog boards for repair and verification 187 1009 I O Upgrade Kit VM7 8852 no photo For those customers who own a VM7 with only one bus connector on the I O card This printed circuit card upgrade will allow your VM7 to control the 8852 without a bus controller GPIB IEEE 488 Cables 1583 3 1 meter GPIB buss cable Three each included in 8850 2 1583 6 2 meter GPIB buss cable 1583 9 3 meter GPIB buss cable 187 1007 1 Rack Mount Kit no photo GPIB IEEE 488 Cables Rack Mount Kit for the 8852 ears only 187 1008 Rack Mount Kit
189. sheet for more information Warranty The Model 2411B is backed by a full 3 year warranty and TEGAM s 30 day no risk trial TEGAM YOUR GLOBAL SOURCE FOR TEST AND MEASUREMENT SOLUTIONS Model 2411B 16 BIT TRUE AWG Specifications Output Waveforms Inputs Up to 100 High definition custom waveforms Sine Square SUM IN SUM IN allows external signal to Triangle Sawtooth DC Pulse Exponential AM SCM FM Lin Log Sweep Sin x x Sinc Gaussian Haversine Circle Noise TRIG IN 4 programmable sync signals per waveform be added to output Gain 1 open circuit at 1OkQ input Z Rear panel TTL trigger input for triggered gated toggled and burst Sequence Generator Optional modes Waveform Transient free Loop and Link CLOCK IN Rear panel sample clock input Repetitions Loop 1 048 575 times TTL 4MHz Link 100 waveforms REF IN Rear panel 10 MHz reference Program 1000 Steps total input The internal crystal File 100 Sequences controlled oscillator will phase lock to the input Waveform HOLD IN Rear panel TTL input to stop waveform PIORIBES ud RTS IN Rear panel TTL input to initiate Resolution Horizontal Points 65 504 max RTS mode Vertical Points 16 bits 65 536 32 767 32 768 Trigger Sources Sample Rate 0 1Hz to 2MHz 10s to 500ns Internal Trigger 0 02 to 10 seconds 4 digit resolution Manual Trigger Front panel button 50ppm accuracy Ext Trigger Input Rear panel BNC con
190. sistance Transfer Standard C 5 SR1010 100 100 ohm Resistance Transfer Standard C 5 SR1010 1K 1 K ohm Resistance Transfer Standard C 5 SR1010 10K 10 K ohm Resistance Transfer Standard C 5 SR1010 100K 100 K ohm Resistance Transfer Standard C 5 SR1030 1 1 ohm Resistance Transfer Standard C 7 SR1030 10 10 ohm Resistance Transfer Standard C 7 SR1030 100 100 ohm Resistance Transfer Standard C 7 SR1030 1K 1 K ohm Resistance Transfer Standard C 7 SR1030 10K 10 K ohm Resistance Transfer Standard SR1030 100K 100 K ohm Resistance Transfer Standard SR1050 1M 1M ohm Resistance Transfer Standard SR1050 10M 10 M ohm Resistance Transfer Standard OYSIIA 2 0000 teb cee cudeud SYSIIA Packages SYSIIA SureCAL T 470 Phase Sequence Indicator 115 700V 400 Hz T 471 Phase Sequence Indicator 115 700V 50 60 Hz TG501A Generator TM502A Mainframe TM502A TB TM502A with Tool Box Plug In usos neon eee TM503B Mainframe TM506A Mainframe TM5003 Mainframe TM5003 RI TM5003 with Rear Interface TM5006A Mainframe TM5006A R TM5006A with Rack Mount TM5006A RI TM5006A with Rear Interface TM5006A R RI TM5006A with Rack Mount amp Rear Interface TM5006A EMC TM5006A with EMC Shielding VM 7 Advanced 30 MHz RF Recie
191. specifications may be changed without notice BACK TO CONTENTS 9 IEGAM TEN TEGAM WAY GENEVA OHIO 44041 2 YOUR GLOBAL SOURCE FOR TEST 440 466 6100 FAX 440 466 6110 AND MEASUREMENT SOLUTIONS www tegam com e mail sales tegam com RS AND PROBES General Purpose Digital Thermometers Select a low cost Thermometer in TC type K or J and get all the accuracy and resolution you need for routine work We make these easy to use thermometers for people whose everyday needs call for basic temperature measurement accuracy and resolution We build these thermometers with a high impact ABS case that s shock proof and splash proof for tool box durability We back them with a full one year warranty Check the application chart below to see which of these low cost thermometers suits your specific needs SPECIFICATIONS ACCESSORIES SUPPLIED 9V battery and manual MODEL TC TYPE RANGE RESOLUTION ACCURACY 874F K F 40 to 199 9 0 5 rdg 1 0 F SEST2UHOSIO99 19erdg 2 F 874C K C 40 to 199 9 0 5 rdg 0 5 C C 85 to 1100 1 rdg 1 C an a5 an REPEATABILITY 0 3 F DISPLAY 31 digit LCD 5 high DIMENSIONS 6 3 x 2 7 x 1 2 Net weight 7 5 oz ACCESSORIES AVAILABLE 8660 tilt stand belt clip 8668 vinyl case 1104 leather case Accurate Digital Thermometers with Analog Output TEGAM s 871A 872A the recognized industry standards are the only handheld digital thermometers with analog output
192. stem IIA consists of an RF Control Unit Model 1805B and a temperature stabilized RF Power Transfer Standard e g Model F1109 Add a customer supplied RF source and a power meter compatible with the sensor being tested and you are ready to accurately transfer calibration factors for a wide range of power sensors Add a customer supplied PC with GPIB and SureCal software and you have a fast automatic precision Model 1805B RF Control Unit RF Level Control power sensor calibration system The RF power Transfer Standard permits the accurate transfer of calibration data traceable to NIST The 1805B uses highly accurate dc power substitution in a precision RF leveling loop Power levels are established by precision resistor networks at dc and are verifiable by an accurate dc voltmeter Use your stable synthesized signal source to step through the calibration frequency points When used in conjunction with SureCal software this process is performed automatically via the IEEE 488 bus Eleven precision power levels of 0 5 and 1 to 10 mW in 1 mW steps permit the Signal Source RF Output Precision sensor meter under test determines actual Temp BIAS RF Output speed Total accuracy is less than 1 2 to SS LED 2 5 RSS Accuracy is dependent on the frequency and VSWR of the device under test F1109 Feedthrough Mount 0 01 to 18 0 GHz TEGAM
193. t 20 10 LA Programmable Test Current Maximum Short Circuit Current 99 00mA Open Terminal Fixed Voltage amp Fixed Current Modes Measurement Modes series or Parallel Equivalent Circuit Dependent on the measurement frequency Auto or Manually Selected Displays Triple High Visibility 4 Digit LED Displays Measurement Speed 18mS Best Measurement Time NOTE Measurement speed is determined by a number of factors including RS232 averaging measurement frequency auto manual range and comparator settings Trigger Internal and External Triggering External Triggering is achieved by RS232 or GPIB Interface Front Panel or Control Connector in Rear of Unit Measurement Terminals 5 Terminal Kelvin Configuration BNC Connectors for Kelvin and a Guard Binding Post Zero Offset Open gt 1kQ or Short Circuit 1k 2 Null Comparator External Buzzer HI GO LO 10 Sorting Bins Set for PASS FAIL of Comparator Functions Absolute or o Comparator for Displays A amp B Stored Settings 9 Stored Instrument Settings May be stored or recalled through the front panel or remote interface Front Panel Key Lock User is able to lock the front panel to prevent accidental bumping of the front panel keys User Interfaces CONTROL I O Connector Standard I O Port RS 232C Standard GPIB IEEE 488 Optional PN 3505 Safety Conforms with IEC 61010 1 CE Marked
194. t puts are grounded to the instrument chas sis to prevent accidental voltage loops A binding post is provided on the front panel for a direct chassis ground connec tion The Models 2340 2350 are cost effective solutions for specialized appli cations where low distortion and precise signal amplification is required These units are particularly suited for high fre quency electrostatic applications that require high voltage Prices and specifications subject to change without notice BACK TO CONTENTS YOUR GLOBAL SOURCE FOR TEST AND MEASUREMENT SOLUTIONS E 12 Model 2340 2350 HIGH VOLTAGE AMPLIFIERS Specifications Electrical Specifications Number of Channels Input Impedance Output Voltage Range Maximum Output Current Output Impedance Voltage Gain Sine Wave Distortion THD Small Signal Bandwidth Full Power Slew Rate Square Wave Response Aberrations 50Q Voltage Monitor Outputs 1 Channel Model 2340 or 2 Channel Model 2350 50Q Direct Coupled 0 to x 200V Direct Coupled 400V p p 40mA per channel lt 0 20 50 Fixed Special Order 10 100 Refer to Figure 4 DC to 2MHz Typical 3dB Refer to Figure 1 200kHz 400 Vpp Sine Typical 0 1dB CL lt 200pF gt 250V uSec lt 0 8 uSec for 200 Volt Step lt 2 50Q Input Z 200 1 Ratio One for each Channel gt IMQ Input Z 100 1 Ratio Safety Conforms with IEC 61010 1 CE Marked Environmental Operating Tempera
195. ted to an accuracy of 20 ppm of nominal with long term accuracy guaranteed to better than 50 ppm Other values have initial accuracy from 50 ppm to 200 ppm Model SRI has been constructed to meet today s high standards of performance The resistance wire used is a modern alloy with excellent stability an extremely low temperature coefficient over a wide range of temperatures and very low thermal EMF to copper A unifilar winding on a flat mica card is used to minimize both series inductance and shunt capacitance The durable aluminum case provides electrostatic BACK TO CONTENTS shielding Gold plated terminals reduce connection errors Terminals appear on the top of each unit They are also brought out the bottom of the case on removable banana plugs This allows plugging two or more units together in either series or parallel for a wide variety of resistance values Four terminal resistance measurements are easily made by using the banana plugs on the bottom of the case as two of the terminals 0 01 and 0 1 values have four terminals on the top and should only be used in four wire configurations For three terminal or five terminal guarded measurements a binding post on top and a banana plug on the bottom provide connections to the case TEGAM H YOUR GLOBAL SOURCE FOR TEST AND MEASUREMENT SOLUTIONS C 1 C 2 STANDARD RESISTOR Specifications Standard Values 0 01Q 0 1 2 1 Q 10 Q 100 Q 1
196. th the 1750 you select your measurement mode Resistance Ohms Comparator or Percentage Comparator and measurement ranges from 2 mQ to 20 MQ You have your choice of reference currents and triggering methods You can also config ure delay times settling times and auto matic thermal and noise rejection If you don t need all this flexibility just hit the AUTO RANGE button and enjoy the ride It s Easy to Operate The 1750 is the state of the art programmable ohm meter that operates via front panel or over the bus Clearly labeled multi func tion keys provide front panel control of range selection reading modes delays trig gers and measurement HOLD Clear menu driven options provide easy setup for more sophisticated oper ation too The Front panel includes a manual TRIG GER and HOLD function and HI GO LO indicators for the open collector TTL output It s Easy to Integrate The 1750 is unbelievably easy to program The 1750 contains a full com plement of interfaces including IEEE 488 RS 232C and RS 422 To maximize your programming efficiency each of these inter faces is operated using the same programming command set and front panel indicators to pro vide continuous status of all operations It s Easy to Calibrate The 1750 is calibrated using the NIST traceable TEGAM calibration standard Model 17508 and a simple keypad entry procedure Front panel calibration makes it easy to maintain the 17
197. th the tenth resistor you can resolve a series parallel value to better than ppm Prices and specifications subject to change without notice DS amp INSTRUMENTS Resistance Transfer Standard System Oil Immersion Provides Thermal Isolation All standards except the 100 kQ step Standard are immersed in a mineral oil bath Oil immersion provides thermal isolation to minimize the effects of ambient temperature variations This means maximum short term thermal stability for the standards The SR1030 also exhibits superior long term stability 20 ppm of nominal for six months 35 ppm for two years 50 ppm typical for five years This gives you longer mean time between calibrations increasing your calibration throughput As an added benefit the oil speeds the dissipation of heat created in the resistors during calibration This heat dissipation further contributes to the stability of the standards Gaskets seal the SR1030 to keep the work surface and measuring contacts clean The gaskets also minimize oil aging and contamination to lengthen the time between oil changes Since the 100 kQ standard can be measured at much lower bridge power than the lower value standards it is not necessary to immerse the standard in oil However this standard still benefits from the thermal lagging effects because BACK TO CONTENTS it is sealed in a chamber using insulating materials that provide approximately the same t
198. the descriptions herein and the current product Prices and specifications may be changed without notice C 6 TEGAM YOUR GLOBAL SOURCE FOR TEST AND MEASUREMENT SOLUTIONS www tegam com BACK TO CONTENTS TEN TEGAM WAY GENEVA OHIO 44041 440 466 6100 FAX 440 466 6110 e e mail sales tegam com Model SR1030 t lo m TO vs yN 20 Accuracy calibrated to 10 ppm e Seven decades of resistance transfer 1 10 100 1 k 10k and 100kO step e 100 1 resistance transfers using series parallel series parallel connection Calibration readings traceable to the NIST are provided Extremely Accurate and Stable The Model SR1030 provides the part per million ppm transfer accuracies and the long term stabilities you need in today s modern resistance metrology and calibration laboratories The SR1030 Resistance Transfer Standards are extremely accurate stable resistance standards that are used on the bench and are light enough to carry with you to remote calibration repair production or R amp D sites The SR1030 consists of six transfer standards in decades from 1 Q to 100 KQ per step Each decade standard consists of 12 nominally equal resistors matched initially to within 10 ppm In addition each decade standard produces three decade values 10 resistors in series 1OR 10 resistors in parallel R 10 and nine of the 10 resistors in series parallel R By making a 1 1 comparison wi
199. ther recognized national calibration facility User Power Sensor Device Under Test This data sheet was current when it was produced However products are constantly being updated and improved Because of this some differences may occur between the descriptions herein and the current product Prices and specifications may be changed without notice Xe Certificate no 2018 01 TEGAM YOUR GLOBAL SOURCE FOR TEST AND MEASUREMENT SOLUTIONS BACK TO CONTENTS TEN TEGAM WAY GENEVA OHIO 44041 440 466 6100 FAX 440 466 6110 www tegam com e mail sales tegam com RF Power Sensor Ac MESUREMENT PRODUCTS ing use Rotation of the splitter voids the calibration and can damage the mount 102 1000 Fits Models F1109 F1116 and F1119 102 1000H Fits Models F1109H and F1119H 187 4003 SWR Measurement Kit no photo This SWR Measurement Accessory Kit P N 187 4003 provides all the items necessary to perform SWR Return Loss measurements for 0 05 18 GHz using either the TEGAM System IA or 8850 Attenuation Measurement System This kit includes SWR Bridges terminations adapters and opens to perform SWR measurements on devices having SMA Type N or GPC 8 Connectors 8000 RF Mount Transport Case This sturdy well padded case is designed to protect your power standards during storage or transport Fits Models F1109 F1109H F1116 F1117A F1119 F1119H M1110 M1111 M1118 and M1120 GPIB IEEE 488 Cables no
200. tomated testing SureCAL has TEGAM drivers and procedures which allow you to manually calibrating and needs streamline your System IIA SureCAL Test Manager for Windows lets you navigate easily with your flexible standards including equipment from Fluke Hewlett Packard Agilent Keithley TEGAM and Tektronix Hundreds of SureCAL procedures are available to reduce your test time while assuring accuracy SureCal Software for RF Power Sensors is included with the System ITA Additional procedures are also available For more information about SureCAL Sofware call us at 440 466 6100 for a FREE demonstration on CD Prices and specifications subject to change without notice ON SOFTWARE SureCAL Calibration Software A N SureCal C PROGRAM FILES HTBWINB3 ACT SURE 123 uae bf Test Profile Current Profile Name Type Status HP 8481A Standard Cal 21 points Default Loaded UUT Monitor STD Monito DataFormat Uncertainty History General UUT Sensor STDSenso Source Amp Test Points Profile Options Nominal Test Level 0 008 dBm Additional Freqs MHz Select M Reference Frequency 50 000 MHz iv 19 000 Iv 500 000 update Start MHz Stop MHz Step MHz 0 000 Iv 1000 000 18000 000 1000 000 Ej 0 008 Create E 0 80808 6 808 6 868 Iz 6 608 d 6 868 6 6868 8 888 P 8 888 Delete 0 000 0 000 0 0080 M 90 008 E 0 000 0 000 0 000 i 0 000 Assign F 0 000 0 000 0 0060 0 000 E 0 000 p 008 0 0
201. trigger output The synchronous output allows external instruments including two or more 2711A units to be hardware triggered by a master 2711A unit This produces multiple phase signals with highly accurate phase offsets Because the 2711A uses the raster scan technique and sequential addressing there is no need to recalibrate phase offsets every time a frequency change is made DDS type generators require this recalibration Systems Ready The Model 2711A is a low cost version of the Model 2411B It has the same basic performance capabilities but rc ps Pare TIRI i wa UIT BACK TO CONTENTS is designed specifically for systems applications where low cost and performance are valued higher than extended front panel functions 2711A includes standard RS 232C and GPIB interfaces WaveWorks M Jr wave creation software is also provided at no additional charge Three multi phase modes are available to synchronize multiple units for phase sensitive applications Function Generator Operation Direct front panel access to 10 standard waveforms with adjustable parameters provides function generator operation for basic lab use For test applications where custom signals are required up to 100 unique waveforms may be stored in waveform memory and recalled via the 2711 A s front panel or the included WaveWorks M Jr wave creation software Effective User Tools Expand the 2711A s memory capabilities by adding an optional
202. ture 0 C to 45 C 32 F to 113 F Ambient Storage Temperature 20 C to 50 C 4 F to 122 F Humidity Range General Input Supply Voltage Power Rating Dimensions H x W x L Weight approximate lt 80 RH Non Condensing 110 220V 50 60 Hz Rear Panel Selectable 100VA 80W 4 51 x 10 14 x11 81 11 5 x 25 8 x 30 0 cm 10lbs 4 5kg Standard Accessories User s Manual 2 BNC to High Voltage BNC Cables 3ft Small Signal Frequency Resp Vpp Out 35 50 34 45 33 32 o z4 31 p o P 7 30 ie 28 26 20 25 al 10 100 1000 10000 i 10 1000 10000 Frequency kH Frequency kH Figure 1 Small Signal Frequency Response Typical Amplifier Gain measured with 900 mV peak to peak input Amplifier Frequency Response 3 dB at 2 MHz Figure 2 Small Signal Frequency Response Typical Amplifier Gain measured with 900 mV peak to peak input Same as Figure 1 but Y axis is Volts instead of dB Vpp vs Fre 450 400 350 300 Qo 250 gt 200 150 100 50 Frequency Khz 1000 Distortic A OOOO OrFPR r
203. ty MR 1 2 125 x 3 25 x 1 125 Net weight 4 oz LEADS 24 leads with 1 heavy duty test clips ACCESSORIES SUPPLIED Instructions ACCESSORIES AVAILABLE 8668 vinyl carrying case This data sheet was current when it was produced However products are constantly being updated and improved Because of this some differences may occur between the descriptions herein and the current product Prices and specifications may be changed without notice YOUR GLOBAL SOURCE FOR TEST BACK TO CONTENTS AND MEASUREMENT SOLUTIONS H 3 YOUR GLOBAL SOURCE FOR TEST AND MEASUREMENT SOLUTIONS TEN TEGAM WAY GENEVA OHIO 44041 440 466 6100 FAX 440 466 6110 www tegam com e mail sales tegam com DIGITAL THERMOMETERS AND PROBES Thermometers TEGAM s 820 Series Thermometers are easier to use more accurate and pro vide more functions than any competi tive unit at any price including Fluke s 50 series Easy to use because every function is controlled by its own accessi ble front panel key Easy to understand because the status of every function is shown on the display Easy to program because one touch of the user friendly keypad changes TC type from K to J to T One touch changes F to C One touch begins or ends min max data recording views recorded data or holds the display It s easy to repeat procedures because the unit retains the functions you ve selecte
204. typical Output Series Inductance 0 35 V Hz Range 2 uH to 30 uH 2 5 V Hz Range 2 uH to 70 uH Output Series Resistance 0 35 V Hz Range 400 mQ to 7Q 2 5 V Hz Range 500 mQ to 12Q Dimensions Height 5 31 in 135 mm Width 17 in 435 mm Depth 20 in 513 mm Weight 13 8 kg 30 Ib Environmental Temperature Operating 59 F 86 F 15 C 30 C Storage 32 F 122 F 0 C 50 C Relative Humidity Operating 20 50 non condensing Storage 15 80 non condensing Order Information Model Part Number Precision Ratio Transformer PRT 73 2 5 V Hz Option 70161 Rackmount Kit 70192 Rear Panel Terminals Option 70193 Manual 70581 Calibration amp Technical Services For warranty and remedial repair calibra tion services and spare parts or for addi tional information on TEGAM sales and service offices around the world contact us at 440 466 6100 ph or 440 466 6110 fx This data sheet was current when it was produced However products are constantly being updated and improved Because of this some differences may occur between the descriptions herein and the current product Prices and specifications may be changed without notice TEGAM YOUR GLOBAL SOURCE FOR TEST AND MEASUREMENT SOLUTIONS BACK TO CONTENTS TEN TEGAM WAY GENEVA OHIO 44041 440 466 6100 FAX 440 466 6110 www tegam com e mail sales tegam com Resistance Calibration amp Decade Resistors Accessorie
205. ucts To purchase online or get a quotation To learn more about TEGAM and its products people amp history To find a representative in your area To download applications notes specifications or product data sheets To get answers to questions about our products e mail us at sales o tegam com To talk to our Applications Engineers Sales Support Staff and get answers to all your questions about life TEGAM and our products call us at 1 800 666 1010 Your Global Source for Test and Measurement Solutions Model 1825 i lv nto gt Ui ble System IIA Can calibrate many popular sensors in 30 minutes or less The accuracy and reliability you have come to expect from TEGAM No software to learn Compact and easy to use All connectors are located on the front panel for easy connection e Rack mount kit available Optional A2LA Accredited Calibrations NOTE Customer must provide an appropriate RF Signal Source DVM and an RF Power Meter for the UUT MEASUREMENT PRODUCTS Economical RF Power Sensor Calibrator The Model 1825 RF Power Sensor Calibrator is an accurate economical and reliable instrument for calibrating RF Power Sensors in the I10MHz to 18 GHz frequency range This instrument detects the level of RF power being applied to an RF power sensor Resulting voltage readings are measured by the customer supplied DVM Cal factors for the UUT are determined by comparing the readin
206. udio Frequency Applications Great Stability due to 5ppm C Temperature Coefficient and 0 15 ppm mW Power Coefficient for values 1 kQ and up Short term switch repeatability 0 24 mQ typical Prices and specifications subject to change without notice DS amp INSTRUMENTS Dekabox In Line Decade Resistors The Model DB62 Dekabox In Line Decade Resistor provides dependable long term service in precision DC through audio frequency applications Six decades of non inductive precision wire wound fixed resistors are mounted in a low noise shielded aluminum housing The DB62 is easy to use The input terminals and a case connected ground terminal are conveniently located on the front panel The dials rotate independently through 360 degrees to simplify and speed settings This allows for a coarse approximation and then BACK TO CONTENTS precise finer steps to provide an exact resistance value Accuracy over a wide range of ambient conditions is assured by the use of resistors with good temperature and power coefficients Repeatability is assured by the use of switches that have multiple contacts of solid silver alloy The Dekabox resistance values are easily read from the large numeral in line presentation above the knobs Resistance per step and current ratings of each decade are presented below the knobs for operator convenience and circuit safety Decade Resistor DB62 1 TEGAM YOUR GLOBA
207. unction with External Buzzer Highly Visible Dual 4 1 2 Digit LED Displays Voltage amp Current Monitors Standard RS 232C amp 1 0 Interfaces Optional GPIB or BCD Interfaces e 3 Year Warranty ENT INSTRUMENTS General Purpose Programmable LCR Meter The Model 3525 is TEGAM s ulti mate solution for applications that require low cost high accuracy imped ance parameter testing Its amazingly flexible design allows it to accommodate a diverse range of testing applications including testing of capacitors inductors coils resistors materials thermoelectric cooling devices piezo electric sensors and other sensors or components The instru ment is ideal for manual or automated operation Nine AC Measurement Parameters Up to 9 impedance parameters are easi ly viewed on each of the 3525 s two 4 1 2 digit LED displays Display A provides accurate and repeat able readings of Inductance L Capacitance C Resistance R or Impedance IZI at a basic accuracy of 0 08 Display B indicates measurement values for Dissipation Factor D or Tan Quality Factor Q Phase Angle 0 Measurement Voltage V or Measurement Current I All parameters are selectable from the front panel and may be measured as Series or Parallel equivalents Prices and specifications subject to change without notice BACK TO CONTENTS Compact The 3525 s compact size is unprece dented and allows side by sid
208. veform palette WaveWorks Jr with its basic waveform library and complete set of design and editing tools provides a wide selection of waveforms and waveform sequences WaveWorks M Jr is a basic version of WaveWorks Pro IM and is included with all 2700 series arbitrary waveform generators at no additional cost Comprehensive Waveform Design Tools In addition to standard waveforms WaveWorks Jr comes with an array of math operations and transfer functions designed to meet your basic wave shape requirements Synthesis in both the time and frequency domain is available by using WaveWorks Jr s FFT and IFFT routines A graphical interface is provided for remote operation of your TEGAM 2711A or 2714A arbitrary waveform generator s controls Sequence Programming Capability One of the features that distinguishes TEGAM arbitrary waveform generators from competitors models is the programmable sequencer Sequencing expands an arbitrary waveform generators memory by linking and looping various waveform segments to produce a continuous waveform output WaveWorks M Jr is used with any of TEGAM s 2700 series arbitrary waveform generators to easily create custom waveform sequences Option Wave 3 2 F Wave 1 MUL G Wave 2 EIS N kj ol Cancel TEGAM ft YOUR GLOBAL SOURCE FOR TEST AND MEASUREMENT SOLUTIONS Prices and specifications subject to change without notice BACK
209. veforms e RS 232C and GPIB Options 100 Step Sequence Generator Rack Mount Kit Signal Integrity Waveforms will always be consistent and repeatable because the 2711A is a true AWG It uses the raster scan technique with sequential addressing of waveform memory and a variable sample clock rate to adjust the output frequency Other generators use phase accumulator based addressing which can skip or repeat waveform data points The typical THD total harmonic distortion plus noise of the 2711A is 86 dB which makes it ideal for applications sensitive to signal quality No other arbitrary waveform generator matches the 2711A s price and performance Prices and specifications subject to change without notice ae won BEL GENERATORS Low Cost 16 Bit AWG Comprehensive Features With superior fidelity and wide dynamic range the 2711A has outstanding performance offering 16 bit vertical resolution with over 64k of horizontal memory Standard or arbitrary waveforms are created through the front panel or waveform creation software The adjustable sample clock ranges from 0 1S s to 2MS s Superior fidelity low cost and wide dynamic range make the 2711A ideal for applications involving high precision low voltage or signal amplification These include power line harmonics audio signals automotive air bags medical devices and a host of other applications Multiple Unit Operation Each 2711A is equipped with a synchronous
210. ver 0000 Contact TEGAM Inc at 440 466 6100 for information BACK TO CONTENTS K 11
211. with Panel Mounting Dual Setpoints Relay Outputs Bracket Relative Humidity 3 RH to 95 RH range at 2 RH accuracy Temperature compensated 10 F to 175 F 1 RH display resolution Temperature 0 F to 180 F range at 0 1 F accuracy 1 resolution 0 C to 85 C 0 6 C accuracy for C version Controls Setpoints 0 RH to 100 RH O F to 180 F Deadbands to 50 RH to 50 F 40 C all digitally displayed Response Time Under 20 seconds Setpoint Outputs Dual SPDT relays 5 amp 250VAC con tact rating Recorder Outputs 10mV RH and 10mV F 10mv C Display 0 56 high brightness digits Off scale indication for open wires Relay ON indicators Input Power 115 VAC 15 50 60Hz 5 watts maximum 230VAC model available HUMITRAN RDP RH TEMP DUCT PROBE TRANSMITTER Adjustable Removable Duct Flange Wall Mounting Bracket Provided Relative Humidity 3 RH to 95 RH range at 2 RH accuracy Temperature compensated 10 F to 175 F Temperature 0 C to 100 C 32 F to 212 F range at 0 6 C 1 F accuracy for 4 to 20ma or 0 to 1V output RDP 20C 4 to 20ma or RDP 10V 0 to 1V Outputs Stainless Steel Housing RH Output 4 to 20 ma or 0 to 1V represents 096 to 10096 RH Input Voltage Range 6 to 30VDC polarity protected for both current and voltage output units Response Time Under 10 seconds HUMITRAN RHT amp HUMITRAN RH RH TEMP TRANSMITTER Compact Wall Mounting e
212. with cable P N 138 652 and all TEGAM Thermistor Power Standards refer to applicable data sheets for mount specifications A front panel switch selects the operating resistance for the power meter Each power meter has a bolometer current meter and a fault LED indicator that illuminates under any condition preventing loop balance Terminals are provided for an external DVM negative bolometer and voltage sense YOUR GLOBAL SOURCE FOR TEST AND MEASUREMENT SOLUTIONS A 17 Model 1804 SINGLE TYPE IV RF Specifications Power Range POWER METER 0 01mW to 30mW Substitution Bridge Accuracy 0 003 Temperature Range Operating 10 to 40 C 450 to 104 F Storage 40 to 75 C 40 to 167 F Connectors Binding Post standard 0 75 spacing for Banana plugs Power Requirements 105 125 or 210 250 Vac 47 to 420 Hz 12 Watts factory optional Weight Net 6 20 Ibs 2 82 kg Physical Dimension Height 3 37 in 85 61 mm Width 9 84 in 250 00 mm Depth 10 24 in 260 00 mm Rack Mounting The Model 1804 can be shelf mounted in any cabinet or rack designed according to EIA RS 310 and MIL STD 189 This data sheet was current when it was produced However products are constantly being updated and improved Because of this some differences may occur between the descriptions herein and the current product Prices and specifications may be changed without notice Certificate n
213. ws is supplied with many printer drivers but not all are covered In this case the user should consult the printer manufacturer for Windows drivers specific to a user s make and model of printer APPLICATIONS Attenuation Measurements The primary function of the Model 8850 and the CAMLab software program is to perform a wide dynamic range attenuation measurements across the 0 01 18 GHz frequency band The addition of a TEGAM Model 8853 Frequency Converter will also allow the Model 8850 to perform measurements over the 18 to 40 GHz frequency range in a coaxial transmission line using this program Return Loss SWR Measurements CAMLab can perform these measurements using an SWR bridge or the Weinschel SWR Measurement Kit P N 187 4003 with the Model 8850 and the CAMLab Software Program Once the measurements have been taken the CAMLab program will display graph or printout both return loss and the VSWR conversion RF Substitution Measurements The Model 8850 can also perform measurements on attenuators with very high attenuation level 90 dB and above by using CAMLab s RF substitution capability This data sheet was current when it was produced However products are constantly being updated and improved Because of this some differences may occur between the descriptions herein and the current product Prices and specifications may be changed without notice TEGAM YOUR GLOBAL SOURCE FOR TEST AND MEASUREMENT SOLUTIONS
214. z reference input The internal crystal controlled oscillator will phase lock to the input Front panel button Rear panel BNC connector WavewWorks Jr for Windows Operating System PC Requirements Interfaces Standard Functions Math Operation Sequence Creation Waveform Analysis Windows 95 98 XP amp 2000 486DX or better with 4MB RAM COM port or National Instruments AT GPIB card or equivalent 2 6 Operators 12 Transfer Functions Optional hardware required Frequency Domain FFT and IFFT up to 500th Time Domain Edit Computer Interface RS 232C GPIB General Temperature Range Operates Storage Dimensions Weight Power YOUR GLOBAL SOURCE FOR TEST AND MEASUREMENT SOLUTIONS harmonic graphic display and tabulation Waveform and digital pattern Point Vertex and Harmonics FFT and IFFT 19 2k Baud max IEEE Std 488 2 1987 73 4 F 5 4 F 23 C 3 C for specified accuracy 32 F to 122 F 0 C to 50 C 4 F to 140 F 20 C to 60 C 10 14 X 4 53 X 11 81 25 8 X 11 5 X 30cm Wx Hx D 11 Ibs 5 0kg 55VA 45W max 100 120 220 240VAC 4596 10 48 to 63Hz BACK TO CONTENTS TEN TEGAM WAY GENEVA OHIO 44041 440 466 6100 FAX 440 466 6110 www tegam com e mail sales tegam com Model 2340 2350 Single or Dual Channel Independent 200 1 voltage monitor outputs for each channel Compatible with all TEGAM Arb
Download Pdf Manuals