Home

English - bartec

image

Contents

1. E Always read the requirements in the certificate and in the documentation for the enclosure wiring diagram etc before connecting the enclosure to power source and mounting other types of other equipment intended for the enclosure All entries to the enclosure must be of ex approved types and all other openings blinded with an ATEX and or IEC approved blindplug The quantity and size type of entries is defined in packing list and or the drawing for the enclosure When removing the enclosure the same precautions apply as those observed when mounting the enclosure Inspection Maintenance TNCD enclosures are made of acid resistant stainless steel and thereof not subject to corrosion Apply GLEITMO 165 grease to lid bolt threads and tapered holes etc We recommend that maintenance is performed in accordance with the IEC 60079 17 60079 1 NEK 420 standards If the flamepaths have evidence of wearing distortion corrosion or other damages the diametric clearance must be checked Technor to be contacted to obtain the valid dimension and clearance It is vital that threads and o ring are protected with GLEITMO 165 grease or other approved greases after they have been dismantled No high pressure water to be applied in the connection between lid and enclosure If any damages are found the enclosure should be put out of service and the manufacture contacted Further technical information s is available on www technor no Fig 1 BARTEC
2. PUSER MANUAL BARTEC gari TNCD Empty enclosure ATEX Date Rev Checked by Approved by Page Document no 20 03 2011 F E T S Gr lof 1 10 CDX 5 Important This manual is intended for empty enclosures If the enclosure contains electrical equipment the Enclosure needs to be certified Marking A certification label is attached to the enclosure ref Fig 1 If not otherwise noted with a special label the standard T amb is 20 to 40 degr C Handling Due to the weight and nature of the enclosures precautions have to be taken to avoid damages to the equipment and the individual The enclosures flame path must be securely protected to avoid damage all openingsto the enclosure and that are not sealed is to be considered a flame path Installation Dismantling When mounting the enclosure ensure that the mounting support is able to take the full weight of the enclosure If any twisting or bending is likely use washers or packing plates as necessary before the screws or nuts are tightened DO NOT OPEN LID BEFORE THE ENCLOSURE IS SECURELY FASTENED AND IN AN UPRIGHT POSITION CHECK CATALOGUE FOR WEIGHT OF LID AND ACT ACCORDINGLY WHEN HANDLING THE LID ALSO CHECK IF ENCLOSURE HAS BEEN SUPPLIED WITH HINGED LID When connecting cables ensure the incoming cables wires are isolated from all sources of power Installation to be performed according standard IEC 60079 14 NEK 420 and or the requirements for the actual installation site NOT
3. fsa rei BARTEC HZA STAVANGER NORWAY STAVANGER NORWAY NEMKO 03ATEX 263U NEMKOOOSATEX263U o O NEMKO 03ATEX 263U NEMKO 03ATEX 263U EMPTY ENCLOSURE WITH Ex COMPONENT CERTIFICATE EMPTY ENCLOSURE WITH Ex COMPONENT CERTIFICATE SEE INSTALLATION INSTRUCTION DOCUMENT SEE INSTALLATION INSTRUCTION DOCUMENT The passing on and copying of this document and the use or communication of it s contents are forbidden without express authority Offenders are liable to payment of damages All rights are reserved in the event of the registration of a patent

Download Pdf Manuals

image

Related Search

Related Contents

manual de instrucciones  Manuel SI-2  DMC-18x2 User Manual - Galil Motion Control  M-Audio Black Box Abbendum al Manual de Usuario  Samsung S22E450F Uživatelská přiručka  Wireless Broadband Router User`s Manual  SERVICE MANUAL  Samsung GT-P3110 Керівництво користувача  Lenoxx Electronics H-5560 Telephone User Manual  GT800 Impresora de transferencia  

Copyright © All rights reserved.
DMCA: DMCA_mwitty#outlook.com.