1.  Mixing Cup  Use the Spatula to remove the alginate material     e Alginate material will set Bubble Free     9  Setting the Mixer Timer     The Timer has 5 pre programmed settings     Memory Mixing Time  seconds   6    Po   2 8  3 10  4 12  5 15       Press the MEMORY SELECTION BUTTON to select one of the  pre programmed time settings required for mixing  The corresponding indicator  light will be lit     e The     and     Time Adjustment Keys can be used to increase and decrease  the time setting for pre set position No  5  The setting range  5 4 16 seconds         Note the Time Adjustment Keys will only change pre set position No  5   e To change the No  5 Timer pre sets       Choose the No  5 pre set position using the MEMORY  SELECTION BUTTON  the corresponding indicator light will turn on        Press the MEMORY SELECTION BUTTON and hold for 5 seconds   it will beep once       Once it beeps  release the MEMORY SELECTION BUTTON       Press the     and     TIME ADJUSTMENT KEYS to increase and decrease  the time setting for that pre set position       Press the MEMORY SELECTION BUTTON to lock in this new setting     e Should you wish to change this setting again or return to the original pre set  position  just repeat the above process        A grid of mixing times  time settings   Water temperature between 50   68  F 10     20  C  are listed below     Alginate Scoops   Mixing Time  seconds    Impressions Made                Small Full Arch    Medium Full Arch  Large Full 
2. AM100  Centrifugal Auto Mixer  User Manual       10     11     12     Table of Contents    User Notice   Warranty Liability Information  Indications for Use   Product Introduction   4 1 Parts and Accessories   4 2 Product Specifications   Installation and Use   5 1 Conditions for Installation and Use  5 2  Installation    Transportation    Power    Mixing of Alginate Powder  Setting the Mixer Timer  Maintenance   10 1 Mixing Cup   10 2 Cleaning the Mixer  Troubleshooting    Product and Accessories    9 10    11    1  User Notice    Thank you for ordering the AM100 Centrifugal Auto Mixer     Prior to using this product  please read this User Manual carefully for  set up  usage and maintenance instructions     Please keep this User Manual handy as a reference for your AM100  Centrifugal Auto Mixer     Please use this machine according to the instructions described in this User  Manual  Failure to do so may result in operator injury or machine malfunction     If the purchaser does not file a written complaint to Great Lakes Orthodontics  within seven  7  days of receiving the product  we will assume the purchaser has  completely understood the contents of this User Manual and accepted the product  as shipped     Please contact Great Lakes Orthodontics 1f you have any problem with the  machine     The manufacturer reserves the right to make changes and improvements to any  of the products described in this manual without prior notice     2  Warranty Liability Information    The A
3. Arch       10  Maintenance  10 1 Mixing Cup    e After setting  the remaining alginate material inside the mixing cup can  easily be removed  Once removed  use a clean soft cloth to wipe it down     e The small hole at the center of the cap  Fig  5  should be cleaned to ensure  that it is not clogged or blocked in any way     Important Information    The small hole at the center of the cap must remain clear  If it becomes  clogged or blocked  then the mixing cup cap will be difficult to open or  close  Any water remaining after cleaning must be removed completely   otherwise it will cause a mixing error        e The Mixing Cup is a consumable component  Once it becomes distorted  or cannot be sealed tightly  please replace with a new one     10 2 Cleaning the Mixer    e Use a cloth to clean any dirt on the outside of the Mixer  Use a neutral  cleaning agent to remove large amounts of debris     NOTE  DO NOT CLEAN THE INSIDE OF THE MIXER  OR THE MIXER WELL WITH WATER     Important Information   Never use solvent or volatile chemicals for cleaning  This may damage  the machine components and will cause the machine surface to fade     11  Troubleshooting       If you experience a malfunction  please try to resolve the problem by  using the Troubleshooting Chart  page 9   Ifthe machine 1s still  malfunctioning  please contact Great Lakes Orthodontics for further  instruction and assistance     Problem    Mixer does not power on turn  on when you press the power  button    The dig
4. M100 Centrifugal Auto Mixer is warranted for one  1  year from date of  purchase     Great Lakes Orthodontics shall not assume any responsibility for any malfunction   damage  or accident of personal bodily injury due to the improper removal  modifi   cation  maintenance  or repair of the AM100 Auto Mixer by parties other than us     Great Lakes Orthodontics shall not assume any responsibility for any malfunction   damage  or accident of personal bodily injury due to using a product not provided  by us     Great Lakes Orthodontics shall not assume any responsibility for any malfunction   damage  or accident of personal bodily injury due to the improper removal  modifi   cation  maintenance  or repair of the AM100 Auto Mixer that did not include parts   provided by us     Great Lakes Orthodontics shall not assume any responsibility for any malfunction   damage  or accident of personal bodily injury due to the improper operation of the  AM100 Auto Mixer not in compliance with this User Manual     Great Lakes Orthodontics shall not assume any responsibility for any malfunction   damage  or accident of personal bodily injury caused due to the usage environment  not being in compliance with the power  installation environment and conditions  specified in this User Manual     3  Indications for Use     Use of this product is restricted to medical dental professional use only     e This product is suitable for mixing 25 100g of alginate powder in a  short time period        This pro
5. duct should not be used to mix caustic material   4  Product Introduction  4 1 Parts and Accessories    Machine body   Cover   Start Stop button   Time memory selection button   Time adjustment buttons   Time display   Time memory number position indicator    Indicator light                  Power cable receptacle   10  Main power switch   11  Power cable   ps Stir stick   I  Spatula   14  Water dosing bottle   15  Mixing cups  4 ea     16  Fixed bolts for transportation    4 2 Product Specification    Power Supply  110v   60Hz   Power  400W   Revolution  3 600 rpm   60Hz   Timer  4 16 sec   adjustable by second   Memory  5  initial settings   6  8  10  12  15 sec    Net Weight  19kgs   41 9 105     External dimension  215mm  w  x 310mm  h  x 275mm  d              5  Installation and Use  5 1 Conditions for Installation and Use       For indoor use only    e Please use at temperatures between 41    104  F 5   40  C   e Please use at a relative humidity of  lt  85     e Please use the power voltage of 110v   60Hz    e Please use at an electric current of 10A     5 2 Installation    Important  Please remove the two  2  fastening bolts fixed at the bottom  of the machine  Fig  1  before using this product  or the machine will be  damaged        The machine should then be installed on a stable counter or table with a flat  surface     e Never install near flammable or explosive substances     e Should the machine malfunction  do not attempt to use  Using the machine  in this cond
6. ital display does not  come on    The initial running is slow    Abnormal noise or vibration  while running    Motor does not start or alginate  mixing is uneven    Troubleshooting Chart    Cause    Bad power cord connection    Main power switch is in OFF  position  rear of Mixer     Burned out fuse    Defect in PC board    Indicator light 1s bad    Defect in driving motor or belt    Defect in the starting condenser    Too much alginate in mixing cup    Mixer started  but there is nothing  inside the mixing cup    Damaged belt    Alginate powder splashes  caused  by loosening of mixing cup cap    Incorrect amounts of alginate and  water  Driving motor triangular belt or    round belt 15 damaged    The sensor lock in the machine  cover is malfunctioning    Method    Inspect power cord connection    Turn main power switch on    Inspect fuse and change if  needed  If the fuse is burned out   contact Great Lakes Orthodontics  for repair instructions    Contact Great Lakes  Orthodontics for repair  instructions    Replace the indicator light    Contact Great Lakes  Orthodontics for repair  instructions    Contact Great Lakes  Orthodontics for repair  instructions    Try smaller amount of alginate    Place properly filled mixing cup  in the unit and retry    Contact Great Lakes  Orthodontics for repair  instructions    Check to see if the mixing cup  on the cap 1s tightly closed    Refer to alginate suppliers  mixing ratios    Contact Great Lakes  Orthodontics for repair  instructi
7. ition may result in additional damage to the mixer as well as  voiding the warranty          Transportation    Important  If the mixer is to be returned for repairs or brought to another    location  please fasten the aforementioned fastening bolts to avoid malfunc   tion or damage     e Not securing the motor with the two fastening bolts when transporting   shipping voids the product warranty  Please store the two fastening bolts  for future use     7  Power    e Connect the Power Cable to the Power Cable Receptacle on the rear of the  machine  Fig  2         Plug 3 prong  grounded end of Cable into the power source  wall receptacle      e Turn mixer on at Main Power Switch located on the rear of the machine  Fig  3    When the switch is turned on  the Memory Indicator Light and Time Display on  the Operation Panel should be lit     Fig  1 l Fig  3 Fig  2       8  Mixing of Alginate Powder    Prepare the alginate powder and cool water  50   68  F 10   20  C  in the Mixing  Cup as described in the next step     Important Information   The hardening times of the alginate can be controlled by water temperature  If  cool water is not used  the hardening time will be shortened     Measurement of the alginate powder should be done according to the alginate  manufacturer   s instructions  Add the corresponding amount of water to the  alginate powder already in the Mixing Cup     The dosage to be mixed should be between 25 100g  In order to prevent  malfunction of the machine  do no
8. ons    Check to see if the machine  cover is closed tightly       12  Product and Accessories    Part Number Description Quantity    100 060 Full Machine  100 061 Power Cable  100 062 Mixing Cup  100 063 Water Dosing Bottle  100 064 Spatula   100 065 Stir Stick       Great Lakes Orthodontics Contact Information     Telephone  800 828 7626  Toll free U S   amp  Canada   716 871 1161  Worldwide   Fax  716 871 0550  Email  info  greatlakesortho com    Website  www greatlakesortho com    Great Lakes Orthodontics  Ltd   200 Cooper Avenue  Tonawanda  New York 14150               4     Ta        gt           D a    SMPI165Rev 110509  S 330    
9. t exceed 100g     Cap the Mixing Cup by covering the cup  then pressing down on it while turning  it to lock it in place     Important Information    The Mixing Cup must be completely tightened or the alginate powder will splash  during mixing and cause the machine to malfunction  The Mixing Cup and Mixing  Cup Cap are considered accessory products and not included in the machine war   ranty  If the cap cannot be secured tightly  please use a new mixing cup and cap     Place the Mixing Cup inside the mixing well  Fig  4            Fig  4                Close the Mixer Cover     The Mixer will not start if the cover is not secured properly     Do not Start Run the machine when the Mixing Cup 15 empty     Based upon the amount of alginate powder added to the mixing bowl  set the  timer  Please refer to Setting the Mixer Timer  section 9      Once the timer is set  press the Start Button  The digital display will count  second by second  and will display the time of completion  Do not force open  the cover while the machine is running as this may cause injury to the operator  or damage the machine     Important Information    Should you need to stop the Mixer during mixing  press the Stop Button and  the Mixer will immediately stop  During mixing  should the Mixer detect any  abnormal condition  it will stop automatically     e The Mixer will beep to indicate that it has completed the mixing cycle     e After making sure that the Mixer has stopped  open the cover and remove  the
    