1. Camera Side view eLens Sold separately C or CS mount Fixed or Vari Focal DC Auto Iris lens eAuto Iris Control Plug Plug for Auto Iris control The following shows each pin connection Damping coil Lens cable 2 Damping coil No 3 Pin t J Drive coil No 1 Pin KI connector Dive coil C isen No 2 Pin Strip 8mm of outer jacket of the lens cable and then strip 2 mm of inner wires to solder them to the connection plug 6 18 XNET Network Box Camera Installation Manual 2 3 2 Rear View RS 485 and alarm Input Output Analog video Output ALARM RS OUT IN 485 ce Power Input Factory Reset Button Bate for 12 VDC Recalls initial factory settings 3060 POWER LED Network Terminal MIC LINE LINE IN OUT Event LED Mic audio Input Audio Output SD CARD Slot Figure 2 2 IP Camera Rear view MIC LINE IN Connects to auxiliary Audio Device or microphone 3 5 mm mono stereo audio connector is used For connection refer to the figure below GROUND GROUND LINE IN mono MIC IN Figure 2 3 Connector for MIC LINE INPUT and Audio LINE OUT LINE OUT mono LINE OUT Audio signal output to a Power Amplified device or Speaker This can be used to listen to the audio signal sent from a remote PC for Bi directional Audio communication VIDEO OUT Use this output to monitor the analog video signal while installing Select Video Out at menu screen to
2. enable this output Factory Reset Button Press and hold for more than 3 seconds while power is on to recall factory default settings 7118 XNET Network Box Camera Installation Manual AAA AAA A A AAA A A AAA A A AAA 22222222 yy AA A 0kz NETWORK This Ethernet terminal connects to 10Mbps or 100Mbps LAN through an RJ 45 connector When optional PoE is used the power will be supplied from the Network Cable m LINK Yellow light indicates that he network is properly connected m ACT Green light indicates that the XNET system connected to 100Mbps LAN This green lamp will blink if the system receives data STATUS LED Indicates the operation status m EVENT LED Green light indicates that Alarm Out signal is turned on m POWER LED Red light indicates that 12V DC power is connected RS 485 and ALARM In Output Terminal ALARM RS Pin Description Setup lt lt lt OUTI IN 1485 Alarm Out Select NC NO at menu screen Alarm Out 3 lea Select NC NO at menu screen Alarm In RS485 C a4 1 m RS 485 When properly connected you can remotely control Pan Tilt device with RS 485 control interface Alarm In This connects to an Alarm Sensor signal Only one sensor can be connected Alarm Out This connects to an external Alarm device that operates by a relay such as Siren Lamp or Alarm Light Only one Alarm device can be connected SD CARD SLOT Enables recording of video data to an externa
3. TH 6 5 18 18
4. Ver 1 0 XNET Network Box Camera IGB1110PF IGB1110NF Installation Manual CNS TECHNOLOGY Inc XNET Network Box Camera Installation Manual About this Installation Manual A compatibility and durability test ensured this product s high performance This installation manual is for XNET IP Box Camera users only and it describes operations related to XNET IP Box Camera Please read this manual thoroughly paying attention to cautions and warnings before using the product even if you have used similar products before Important Notices The copyright of this manual is owned by CNB Technology Inc It is illegal to copy and distribute this manual without permission Damages caused by use of not suggested parts and misuse will not be applicable for support Contact the store or the manufacturer immediately if you think there is any problem with the product Contact the store or the manufacturer before disassembling the product for alteration or repair XNET is a trademark of CNB Technology Inc This product complies for CE Europe and FCC USA regulations for industrial home use electrical device INFORMATION This eguipment has been tested and found to comply with the limits for a Class A digital device pursuant to Part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference when the eguipment is operated in a commercial environment This eguipment generates use
5. ation and user interface as well as multi functional compressor Codec such as MJPEG MPEG 4 and H 264 XNET provides stable real time surveillance by real time video audio at D1 level local storage for any network problems and hybrid IP technology that can be used with existing analog CCTV devices 1 2 Features of XNET Most advanced Video Audio compression technology MJPEG MPEG 4 H 264 ADPCM G726 Hybrid IP Technology CCTV analog video output can be used for existing analog CCTV devices Transmission of Multi Codec stream Live video signal can be compressed to MJPEG or MPEG 4 or H 264 and sent to meet various applications of network or user 2 way Audio Communication Bi directional voice communication between Client s PC and XNET Smart Event feature On the top of motion detection and sensor alarm feature pre and post alarm feature allows automated surveillance without an attendant s monitoring Install Operation Wizard Install Operation Wizard not only makes it easy for installers and users but also offers a unified installation setup for massive scale installations Up to 3 motion detection areas Motion Detection Alarm output and Video Audio data transmission to FTP site or e mail upon detecting a motion RS 485 interface for Remote Pan Tilt control Remote Control over the network for software upgrade 1 3 Applications Surveillance Building store factory parking lot financial institutions government bui
6. er and click select button to change the IP address of the camera 12 18 XNET Network Box Camera Installation Manual 4 Using Web Viewer Connecting to network devices can be done using internet web browser or XNET CMS software This manual explains about using internet web browser only For instructions on how to configure network connection using XNET CMS software please refer to XNET CMS Manual which can be found in the installation CD 4 1 Logging In Enter the IP address of the device on the address bar of your web browser and press enter key Then the following webpage will appear o amp E 69 http 192 168 123 35 html view index html Pp Bax O 192 168 123 35 AA Cs EDETEN 19 Windows Security The server 192 168 123 35 at CNB Network reguires a username and password Warning This server is reguesting that your username and password be sent in an insecure manner basic authentication without a secure connection f User name Password r E Remember my credentials A Caps Lock is on RTSP 192 168 Stream Protocol Dual Stream Service RTP over TCP Main Stream MPEG4 H 264 MJPEG Sub Stream MJPEG Note UDP can cause a network overload in a network with low bandwidth poor performance Therefore we recommend to use UDP in local networks or high bandwidth networks only If Web Viewer program is not normal
7. ion page You can add or delete areas for detecting motion in this page Motion Detection Please refer to XNET Owner s Manual for detail Opens up Multi View page You can view videos from cameras that are programmed in Multi Video Multi View Player setup page Please refer to XNET Owner s Manual for detail When this box is checked Main Stream Video is displayed When this box is checked Sub Stream Video is displayed Live View Dual Codec needs to be enabled in Video Setup Page in order for Sub pup eed Stream to be displayed Please refer to XNET Owner s Manual for detail 16 18 XNET Network Box Camera Installation Manual 5 Specifications OR Specifications OO OOOO 1 3 High Sensitivity CCD Sync System n Resolution Video Output Level ES Day amp Day amp Night System piatat Sow shater Slow Shutter osp Men PN DNR Brightness Sharpness Sharpness 1 100 sel Function On Off 16 Zones Control On Off 8 zone settings over IP Stabilizer On Off D Effect V Flip Mirror Rotate Electronic Shutter o 1 60 1 90 000 Sec 1 50 1 90 000sec Compression MJPEG MPEG4 H 264 Single Mode Main H 264 30fps D1 Frame rate Dual Mode Main H 264 MPEG4 30fps Second MPJEG D1 Video Audio CIF NTSC 352 x 240 PAL 352 x 288 MJPEG H 264 or MPEG4 Dual mode Constant and variable bit rate in MPEG4 128kbps 3M bps Controllable frame rate and bandwidth Ip
8. l memory device upon occurrence of an event Please use less than 4 GB SD Memory Write protect tab Labeling position Direction Figure 2 4 SD CARD Power Terminal Connect 12V DC Power to this terminal Do not use this connector when powering up the product through LAN cable PoE The product is not covered under warranty when it is damaged by connecting both Ethernet power and 12V DC power to this terminal 8 18 XNET Network Box Camera Installation Manual pe N WWW WIN 2 3 3 Connecting to Alarm devices Alarm Input Wires from various sensor type IR heat and magnetic can be connected to Alarm in terminal as shown in figure 2 5 NC or NO of sensor input can be selected at Menu screen Alarm Sensor device reguires a separate power source Signal 5 30VDC Alarm in Sensor Adaa Device Photo Coupler Alarm in Internal Circuitry External Circuitry Figure 2 5 Connecting to Alarm Input Alarm Output This terminal can only be connected up to AC 30V 400mA or DC 30V 400mA An additional relay device has to be used to control higher voltage or current Alarm out ALARM DEVICE Alarm out Internal Circuitry External Circuitry Figure 2 6 Connecting to Alarm Output 9 18 XNET Network Box Camera Installation Manual 3 Software Installation This section provides brief guidelines to install the XNET software guick
9. ldings military facilities etc Remote video monitoring Hospital kindergarten traffic monitoring remote branch office weather environment preservation and illegal disposal of trash etc Real time broadcasting over the internet Resort facility parties festivals etc remote business meetings and educational trainings etc XNET Network Box Camera Installation Manual 2 About the Product 2 1 Contents Please make sure the following contents are included when you open the package XNET product IP Box Camera Lens not included eo Auto Iris Lens Plug Connection plug for Auto Iris control signal 4 Input 100 240VAC 50 60Hz ld Output 12VDC 2A Cure EI BO AC power Cord 2 jack cable Software and User s manual 2 2 Product Information XNET IGB1110xF Modal Name CNB_XNET A software that monitors and records Audio and Video signal from the device processes up to 16 channels IP Camera Lens not A software that assigns an IP included address to the product 5 18 XNET Network Box Camera Installation Manual 2 3 Functions and Designations 2 3 1 Side View Mounting Screw Hole 1 4 20 UNC 20 THREAD L 4 5mm 0 2mm ISO standard or 0 197 ASA standard g Auto Iris control plug N KIEL N Lens Sold Separately CS Ring Attach CS Ring only to use CS mount Lens Please ask at the store about purchasing lens separately Figure 2 1 IP
10. ly and to monitor XNET s Video and Audio signals easily If you have guestions about details not explained in this section or if the product is not functioning as described please refer to FAO before contacting the store Our homepage is http www cnbtec com 3 1 Connecting XNET to network 1 A PC or a laptop computer is required to set up an IP address e Compatible operating system Windows 2000 Windows XP Windows Vista e Since the default IP address of the device is 192 168 123 100 set up the IP address of the computer like the following IP Address 192 168 123 101 Subnet Mask 255 255 255 0 2 Connect a monitor to VIDEO OUT terminal Select Video Out at Menu screen to enable analog video output 3 Connect LAN cable to the Network Terminal of the product Use a crossover cable when connecting it directly to a PC and use a direct cable when connecting it to a HUB Crossover Network Cable NETWORK HUB EA IL Direct Network Cable 4 Connect the camera to the power 5 Use the Alarm Sensor output and audio terminal if necessary 10 18 XNET Network Box Camera Installation Manual A 4 A O z ZE x lt lt lt lt lt NI rl AA 3 2 Installing IP Installer Software and Configuring IP address 3 2 1 About IP Installer A unique IP address has to be configured in order to connect IP camera a
11. ly installed automatically please select the following link to install Web Viewer program manually ActiveX authentication certificate is expired or user s O S does not support ActiveX Click here to install Web Viewer Warming Please check your internet connection before you install Web Viewer program manually Figure 4 1 Log in Box 13 18 XNET Network Box Camera Installation Manual AAA AA A A AAA A A AAA A AAA 22222222 xx lt x T o zZP__P _k _ P _ Enter the user name and password to bring up the web viewer page The default id and password is root admin respectively If you want to use a different HTTP port number from the default value simply put a colon and port number at the end of the IP address For example enter the following address when changing the port to 8080 http 192 168 123 100 8080 lt Address format for accessing as an administrator gt When using default IP address and port number http 192 168 123 100 When IP address and port number changed http IP address new port number For security please change the administrator s id and password from their default values Please save the changed ID and password in a place only accessible by an administrator Please refer to Web Viewer Manual for detail If you forget the administrator s password Factory Reset is the only way to regain access However since this will retrieve all default settings the ne
12. nd monitoring PC to a network IP Installer software provided in the Installation CD included in the package and also available to download from our website http www cnbtec com will configure IP address easily If your network have a DHCP server that automatically assigns IP addresses to IP cameras If your network does not have a DHCP server the default IP address of the device is 192 168 123 100 Refer to IP Installer user s manual for detail 3 2 2 Configuring IP Address 1 The following box will appear when you start the IP installer software f IP Installer Yer 1 0 9 Release m hu x File Work IP A 8 E IR Model Name MAC Address IP Address Pot IGB1110PF OD FSIFFFFFF 192 169 125 100 80 Figure 3 2 IP Installer Start box 11 18 XNET Network Box Camera Installation Manual 2 Select the camera of which you wish to change the IP address and click IP Set IP Address button to bring up the following box in Figure 3 3 Set IP Address MT xi IF Address Setting Serial Number U0l EGIFFFFFF IP Address de 166 leo O To enable IP address assignment please restart the network camera and wait 10 seconds Set Close Figure 3 3 IP Address box 3 When you enter the IP address and click Set button the box shown in Figure 3 4 will appear Select Network Adapter E x Network Adapter List Select Figure 3 4 Select Network Adapter Box 4 Select the adapt
13. s and can radiate radio freguency energy and if not installed and used in accordance with the instruction manual may cause harmful interference to radio communications Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be reguired to correct the interference at his own expense 2 18 XNET Network Box Camera Installation Manual kt s t lt 2 st 111 1 8143 1ADOUCANE od A A kaus kaa soma 4 EA BOU A aan 4 12 Features ON E do 4 li SA PDICSIO NS late cca 4 2 ADOUTTNE Production 5 Mss OIS MES aseina E ii eee 5 2 2 PIOCUGE INTO MAIN ad 5 2 0 FUNCIONS Ana DOSIGMANONS a o lion 6 LINES VEW ta 25 kasaa amma LA E AO A 6 SA IN SA IS A ES TO 5 E O T 2 39 GONNECING to Alarm ASVvICOS samson da 9 3 SOMWANES installations 10 3 1 Connecting XNET to NetWork arcani a E a ai 10 3 2 Installing IP Installer Software and Configuring IP address n 11 d 2 IAboutiP Installerfis a RI ra 11 3 2 2 Conigurnnd IPAdGressiRan id ani 11 A lt USING WED VIOWO sii aa 13 ANAL 910 A A PRAKTIKEN dd o e A 13 ALO EME PA A sehen Kaa O Sea lia aasia aa ReSi 14 Six SDECITICALION S a an 17 3 18 XNET Network Box Camera Installation Manual 1 About XNET 1 1 About XNET XNET is an internet based security and surveillance system that is compatible with various network conditions through easy install
14. twork settings have to be configured again using the IP installer 14 18 XNET Network Box Camera Installation Manual 4 2 Web Viewer Page Web viewer page consists of Video monitor screen and menu option buttons MPEG4 640x480 Stream Protocol Dual Stream Service RTP over TCP f 8 Main Stream MPEG4 H 264 MJPEG Sub Stream MJPEG Note UDP can cause a network overload in a network with low bandwidth poor performance Therefore we recommend to use UDP in local networks or high bandwidth networks only IT Web Viewer program is not normally installed automatically please select the following link to install Web Viewer program manually ActiveX authentication certificate is expired or user s O S does not support ActiveX Click here to install Web Viewer Waming Please check your internet connection before you install Web Viewer program manually Figure 4 2 Web Viewer Page 15 18 XNET Network Box Camera Installation Manual ten shen te Captures and saves the current image as a still picture The image is saved as jpeg file in the following folder C WxNetCapture Brings up Menu screen Setting Setup page for each XNET feature can be opened from this Menu screen Please refer to XNET Owner s Manual for detail Opens up PTZ page This page can set up digital PTZ of the IP camera and control of PTZ PTZ movement Please refer to XNET Owner s Manual for detail Opens up Motion Detect
15. v4 HTTP HTTPs UDP TCP RTSP RTP SMTP FTP ICMP DHCP UPnP Bonjour ARP DNS DynDNS NTP IGMP Multicast OnVif eat Spered DONS 1 CNB DDNS 2 DynDNS org SATA PP 3 Reference code with SDK LAN Interface Ethernet 10 100 Base T RJ 45 Type Support PoE Standard IEEE 802 3af supported N ty Access level setup Multiple user access levels with password protection ecuri Network Security IP Filtering Image detection Motion detection Select 3 Regions each area Sensor detection Sensor In Scheduling Alarm out Alarm and Event After Event process JPEG Image upload over FTP server SMTP E mail server Management JPEG Image write to Internal amp SD card memory Internal memory Max 32MByte SD memory Support size Max 4GByte Video streaming Protocol Local storage 17 18 XNET Network Box Camera Installation Manual Detail time set Max Pre alarm 5 sec Post alarm 8 sec Pre Post alarm Local storage Internal memory or SD card memory JPEG image LA Browser Internet Explorer 6 0 or later Applications A Lu W Monitoring Application CNB NVR CNB CMS and Utility IP Installer etc System Upgrade Firmware upgrade over HTTP Maintenance Kesse alani JSENMt ol OCO C 1 1 jj PTZ control RS 485 PTZ Protocol Service User define update Operating Temperature OC 40C dan DC 12V Max 5 W Dimensions Weight Net 137 9 D x 91 W x 62 H mm 1 4 20 UNC 2B DEPTH 6 5 5 4 HOLE DEP