1. Manual l o oco installation floppy disk Parallel Programmer V2 x y 1 2 2 2 Installation All connections slots labels of the external parallel programmer are shown in Fig 1 4 Rear view CENTRONICS Type plate with Power On off Voltage serial No supply selector switch product status P16 slot P32 slot Power LED Busy LED Fig 1 4 External parallel programmer Connect the parallel programmer to the CENTRONICS interface of your PC using the cable supplied When doing this observe which interface is configured LPT1 LPT2 You will require this information when installing the software Connect the parallel programmer to the line supply CAUTION The parallel programmer can be supplied with either 230 V AC or 115 V AC 230 V AC is pre selected Check that the parallel programmer setting corresponds to your particular line voltage supply Fehler Nur Hauptdokument 6 Edition 05 95 Siemens AG 465 982 7102 01 SIMADYN D Parallel Programmer User Manual 1 Introduction 1 3 Introduction 1 3 1 INSTALL EXE installation program The software is supplied with an installation program which sets up the following directories on your PC and copies the files from the floppy disk into the directories c SIMADYN Driver program parallel programmer c SIMADYN PGM Utility programs and PG driver programs c SIMADYN MDS Message text files c SIMADYN BIB Basic STRUC software c
2. Parallel programmer as DOS drive SRAM standard PCMCIA memory cards and SIMADYN memory modules MS5 MS55 MS45 can be used in the parallel programmer as DOS compatible data medium In order to be able to use the memory modules as MS DOS compatible memory medium these must be formatted just like floppy disks before they are first used they are formatted using the utility program MELFORM EXE Formatting is started by entering MELFORM m enter key m specifies the drive name which is to be formatted Special options or parameters are specified in the actual READ ME and MELFORM DOC file on the floppy disk supplied MELFORM then prompts you to insert a card or a memory module into the parallel programmer Formatting is then started by entering The formatter automatically identifies the size of the inserted card or module For PCMCIA memory cards an address space of 8 kbyte to 64 Mbyte is supported If the formatter identifies data medium errors or a parallel programmer fault then these are appropriately signaled Only PCMCIA memory cards and SIMADYN memory modules can be formatted using MELFORM EXE which are either written into or read out of such as SRAM and EEPROM Otherwise an error message is output For RAM cards with write protection switch this must be set into the OFF position Fehler Nur Hauptdokument 12 Edition 05 95 Siemens AG 465 982 7102 01 SIMADYN D Parallel Programmer User Manual
3. bib set ST_SYSTEM c simadyn pgm set ST MDSDAT c Nsimadyn mds V Re start your computer The following files must be stored for the MVPP utility program in the library path ST SAWBIB P16 O asw bin O gsw bin P32 O asw br3 O gsw br3 O bsw br3 O isw br3 If aSTRUC L system V3 x is installed in your PC as standard then the path structure is as follows cA L struc L userO L usert In this case the set commands should be set as follows in the AUTOEXEC BAT set ST_SAWBIB c struc user0 set ST_SYSTEM c simadyn pgm set ST MDSDAT c NsimadynNmdsN Siemens AG 465 982 7102 01 Edition 05 95 Fehler Nur Hauptdokument 9 SIMADYN D Parallel Programmer User Manual 1 Introduction 1 4 Introduction 1 4 1 Installation test of the drive STRUC G To test the parallel programmer end the active DOS window with QUIT and open a new one with the entry dos tamcrd340 f enter key STRUC L The PC must be re booted after the device driver was correctly installed in CONFIG SYS so that the SIMADYN SYS driver is loaded STRUC L and STRUC G The driver must now log on as follows Example SIMADYN DRIVER V2 1 c 1994 CSM GmbH Installed as drives D E Uses Port 378 The SIMADYN SYS device driver always generates two drive letters the first drive always refers to the P16 slot the second drive always refers to the P32 slot NOTE It is not permissible that both slots are simultaneously used If this is the case t
4. 1 Introduction 1 Introduction Contents Page TntroductiOn 2 0 2 2 22 222 202 200220222002202220022022202220022002202220222022202020222020702220007022202020222000202220 2 202 20 2 c0 1 MEO or 2 1 2 Installing the parallel programmer hardware sssssssssssssssseeeeeeeeee enne nnne n nennt nennen nsns 4 1 2 1 Internal VerSIOD esce cese etes eoe coeno ro esee Co daa a Co a a Ta Co a Ta Ta Co a e Ta Ce ETE Ta CEDE TR Te T TE TR Ta TAA L Ta FA A a CANA Au uc 4 1 2 1 1 Scope ot Supply ao eo eut teret ee ee us ue ev ute ety uno e uto uu ee te log Leo ues Le ieu enu tu itta 4 1 22 12 Installation RRRRRRRRRRRRRRRRRRRRRR EEE HEELS 4 1 2 2 External Versioni ice aa e ataa tete ed educ este dede ed e ede qud e pee qud e pa b pube pu b gebe pe bd pe be pu b qu e Le bd pa Le Le bd Ue be Ue b Ub be de 6 1 2 2 1 9C0D6 0f SUPP IY sais sete ttam cute tut ctr cutus eum tete Oe ume set cusu mesure E um Pet need rco eed 6 1 2 2 2 nstallatiOn sese ee eee eee eee eee evade eve eua eve ea eva eua eee eee eee A eae 6 1 3 Software installation 4 ch cte eee testes et eet eae ped eeea dtes ee eee eae ende es e edu e nhe eap age 7 1 3 1 INSTALEE EXE installation Drograiri 2 0 9 2 22 9 0 eR i QUOD Det Pe S a eR Re RA 7 1 3 1 1 Installing the parallel programmer for STRUC G operating system SCO ODT V3 0 8 1 3 1 2 Installing the parallel programmer for STR
5. Pulse 100 us programming pulses INTEL standard algorithm 1 ms programming pulses 1 4 2 2 FLASH cards in the P32 slot The following memory types can be programmed in the P32 slot MS55 SRAM 2MB EEPROM 8 kB attribute memory MS5 FLASH 2MB EEPROM 8kB attribute memory 1 4 3 Test using MELCOPY Using the MELCOPY EXE tool you can check whether the parallel programmer was successfully installed Enter the following to start MELCOPY cAsimadynmelcopy b enter key The following menu is displayed DOS shell Erase FLASH card Drive Status Battery Check Battery Change Hex Edit Siemens AG 465 982 7102 01 Edition 05 95 Fehler Nur Hauptdokument 1 1 SIMADYN D Parallel Programmer User Manual 1 Introduction Now select the tools menu item using the arrow keys and depress f Now position the menu bars under the drive status sub item and depress You can now select the required drive using the arrow keys the first drive is always the P16 slot If you have selected the drive press again if the installation was successful a message window opens with various pieces of information regarding the drive However if the drive was not able to be identified then a window appears with an error message If this occurs please check that all of the installation instruction points have been observed Please refer to the MELCOPY DOC file for further information regarding MELCOPY 1 4 4
6. SIMADYN AW D User files c SIMADYN AWD PJV400 Standard project Files on the parallel programmer installation floppy disk INSTPP1 EXE Installation program parallel programmer INSTALL BAT Installation program utility programs Driver programs SIMADYN SYS Driver parallel programmer CASIMADYN MEL Parallel programmer test programs C SIMADYN PG and X Driver SIMATIC PG programming interface C SIMADYN PGM READ ME Current information on the various programs Utility program MSPP MSPP EXE Dialog program C SIMADYN PGM L3DIA MDS Message texts from the dialog program C SIMADYN MDS DOSTRU MDS Message texts from the dialog program C SIMADYN MDS LSSTRUEX EXE Control program C SIMADYN PGM L3STRU MDS Message texts from the control program CASIMADYNWMDS Utility program MSVR MSVR EXE Dialog program C SIMADYN PGM R5DIA MDS Message texts from the dialog program C SIMADYN MDS RARCOP EXE Control program VOR ON C ASIMADYN PGM RARCOP MDS Message texts from the control program VOR ON CASIMADYNWDS R4RCOP INI COM interface file R5RCOP EXE Control program VOR OFF C SIMADYN PGM R5RCOP MDS Message texts from the control program VOR OFF CASIMADYNWMDS Siemens AG 465 982 7102 01 Edition 05 95 Fehler Nur Hauptdokument 7 SIMADYN D Parallel Programmer User Manual 1 Introduction 1 3 1 1 Installing the parallel programmer for STRUC G operating system SCO ODT V3 0 Log on as root on an ASCII
7. The following programs are loaded on the parallel programmer V2 1 floppy disk Driver programs SIMADYN SYS DOS driver for the parallel programmer PG and X DOS driver for the SIMATIC PG programming interface Utility programs MSVR Pre processing RCOP ON OFFLINE MSPP Module programming The driver programs are required to program or read SIMADYN MSx memory sub modules using the parallel programmer MSPP and MSVR are DOS utility programs which can be used to program the MS modules without the STRUC G L 4 2 configuring software or which can be used to read out the change and configuring data offline and online without the RCOP 4 2 service software The parallel programmer is a programmer for SIMADYN P32 and P16 modules Two slots for the two different memory types are accessible from the front panel The slot for P16 modules is located on the lefthand side and the narrower slot for the P32 modules on Type plate with the righthand side Fig 1 1 serial No prod uct The following SIMADYN module types can be status inserted in the P16 slot MS41 44 EPROM MS45 SRAM MS47 EPROM MS300 EPROM P16 slot MS48 Flash EPROM Busy LED Power supply CENTRONICS P32 slot Power LED D ee The following SIMADYN module types can be inserted Fig 1 1 Parallel programmer in the P32 slot MS55 SRAM MS5 FLASH Or Standard PCMCIA memory cards Feh
8. UC L ssssssssssssssssseeeeeeeeennnmemenn nnne nennen nens 8 1 3 1 3 Manual software installation ccccccccccccccccceeeeeeeee eee e eee e eee e eee e eee e eee e nnn en nn nn nnn nnn nnn nn nnns nnns 9 1 4 Installation test of the parallel programmers ssssssssssssssseeeeneeeneeeene nennen nnn nnne nnns 10 1 4 1 Installation test of the VE a a a nnne nnn nnn nnne nn nnn nnn nnns sns sss AEAEE EENE EELS 10 1 4 2 EPROM modules and FLASH cards ssssssssssssssseeeenenennnennn nn nnn nnne nn nn nnns nnns nsns neis 11 1 4 2 1 EPROM modules in the P16 slot sssssssssssseseeenenennnnnenn ne nnn nn nn nnn nnn nn nnn nnns nnns nsns nnns 11 1 4 2 2 FLASH cards in the P32 slot sssssssssssseeennenennnnne nnn nnn nnn n nnn nn nnn nnns nnns nsns nsns sss nis 11 1 4 3 Testusing MEE CO Piya iet e e a a aaa eu eae 11 1 4 4 Parallel programmer as DOS drive ssssssssssssssssssssseseseeeeen eene nennen nennen nnne enhn t nnne enean 12 Siemens AG 465 982 7102 01 Edition 05 95 Fehler Nur Hauptdokument 1 SIMADYN D Parallel Programmer User Manual 1 Introduction 1 1 Overview The SIMADYN D parallel programmer product consists of hardware and software components The parallel programmer hardware is available in 2 different versions PPlI Internal version for installation in PCs PP1X External version with connection to a parallel LPT interface
9. alling your STRUC G system then the installation is now completed If not then you must call up the STRUC G installation again and select the burn menu item For more detailed information refer to the STRUC G Manual 1 3 1 2 Installing the parallel programmer for STRUC L Insert the Parallel Programmer V2 1 floppy disk in a drive e g a Start the installation with a install b enter key The additional steps are then the same as when installing STRUC G Fehler Nur Hauptdokument 8 Edition 05 95 Siemens AG 465 982 7102 01 SIMADYN D Parallel Programmer User Manual 1 Introduction 1 3 1 3 Manual software installation Create the directories in which the utility programs and drivers which are necessary to operate the parallel program can be copied on your hard disk e g C SIMADYN Insert the Parallel Programmer V2 1 installation floppy disk in your floppy drive e g a Copy the files from the floppy disk into the target directories Supplement your CONFIG SYS with the following line DEVICE C SIMADYN SIMADYN SYS A XXX xxx is the port address of your CENTRONICS interface The standard address for LPT1 is 378 H LPT2 is at 278 H Some manufacturers e g COMPAQ sometimes use the address 3bc H Please take the details regarding the permissible drive parameters from the READ ME file Supplement AUTOEXEC BAT with path c Nsimadyn set ST_SAWBIB c simadyn
10. console Start DOS emulation using dos enter key Insert the Parallel Programmer V2 1 floppy disk in a drive e g a Start installation with a install J enter key The first step is to select either German or English dialog The installation program recommends a drive and a directory in which the program files should be copied e g c simadyn Acknowledge this recommendation with enter key or enter the required drive and directory The parallel interface LPT 1 or LPT2 must now be specified at which the parallel programmer is to be connected You can start the installation program at any time in order to change the device driver parameter LPT 1 or LPT2 Specify the same directory as for the initial installation The installation program then copies all of the required files into the specified directory and automatically makes the entries into the CONFIG SYS and AUTOEXEC BAT files Entries AUTOEXEC BAT The installation directory of the driver is attached to the existing path the environment variables are set for the utility program at the first installation set ST_SAWBIB c simadyn bib set ST SYSTEM c simadyn pgm set ST MDSDAT c NsimadynNmdsN CONFIG SYS If you selected as directory c Nsimadyn and the parallel programmer is connected to LPT2 the following line is entered device c simadyn simadyn sys A 278 If you have already specified the parallel programmer when inst
11. he parallel programmer outputs an error message The parallel programmer can be immediately addressed under the drive name specified in the boot message e g D and E The parallel programmer is ready if the driver is correctly loaded and the parallel programmer was correctly installed There are two openings on the front of the parallel programmer to insert SIMADYN memory modules left the larger P16 slot for MS4X modules right the narrow P32 slot for MS5X modules CAUTION It is not permissible to remove an MS module when it is being accessed It could be destroyed The red busy LED is lit when it is being accessed Fehler Nur Hauptdokument 10 Edition 05 95 Siemens AG 465 982 7102 01 SIMADYN D Parallel Programmer User Manual 1 Introduction 1 4 2 EPROM modules and FLASH cards The MELCARD manager MELCOPY EXE is included with the parallel programmer which allows easy access to all of the memory types supported by the parallel programmer The MELCOPY DOC on the driver floppy disk contains the complete Instruction Manual for this program 1 4 2 1 EPROM modules in the P16 slot The following modules can be programmed in the P16 slot MS41 44 EPROM 512kB EEPROM 2 kB MS45 SRAM 512kB EEPROM 8 kB MS47 EPROM 512 kB EEPROM 2 kB MS48 Flash EPROM 512 kB EEPROM 8 kB MS300 EPROM 512kB EEPROM 2 kB Two programming algorithms are supported for programming EPROM modules INTEL Quick
12. ler Nur Hauptdokument 2 Edition 05 95 Siemens AG 465 982 7102 01 SIMADYN D Parallel Programmer User Manual 1 Introduction CAUTION The ESD guidelines must be observed when handling SIMADYN D modules There is an internal PP11 and an external PP1X version of the parallel programmer The internal version consists of 51 4 drive compartment which is installed in the PC The power supply is realized from the PC power supply unit The external version has its own housing It draws its power from the 230 V supply In both cases communications with the PC is realized through a CENTRONICS interface For the internal version an appropriate interface card is included in the scope of supply This is typically configured as LPT2 so that the standard LPT1 interface remains free for the printer The external unit can be connected to every CENTRONICS interface The device driver SIMADYN SYS generates two new drive letters The P16 slot is addressed under the first drive and the P32 slot under the second CAUTION The device driver SIMADYN SYS generates two new drive letters Thus drive substitutions for example using the MS DOS command SUBST should be used with care Siemens AG 465 982 7102 01 Edition 05 95 Fehler Nur Hauptdokument 3 SIMADYN D Parallel Programmer User Manual 1 Introduction 1 2 Introduction 1 2 1 Internal version MLFB 6DD1672 0AFO Code PP1I Item No 634 683 1 2 1 1 Scope of supply parallel p
13. rogrammer in the 514 installation rack CENTRONICS plug in card pre configured as LPT2 cable set for a CENTRONICS interface ribbon cable V piece for the PC power supply connector l mA oce installation floppy disk Parallel Programmer V2 x y 1 2 1 2 Installation The position of all of the connections slots labels of the internal parallel programmer PP11 are shown in Fig 1 2 Power Type plate with supply serial No CENTRONICS product un P16 slot P32 slot Power LED Busy LED Fig 1 2 Internal parallel programmer NOTE Please take the details for installing options from your PC Manual Fehler Nur Hauptdokument 4 Edition 05 95 Siemens AG 465 982 7102 01 SIMADYN D Parallel Programmer User Manual 1 Introduction Switch your PC off Open up your PC Insert the parallel programmer into a free 51 drive compartment and retain it using the screws provided In order to guarantee an optimal ESD connection it should be noted that there should be a connection between the parallel programmer rack and the PC housing Connect the CENTRONICS plug in card with the parallel programmer using the ribbon cable Observe the correct polarity The red core of the ribbon cable must be inserted at pin 1 of connector strip PTR2 Fig 1 3 c LN PTR2 Fig 1 3 CENTRONICS plug in card Before installing the CENTRONICS plug in card it should be checked whether this is correc
14. tly set for your PC jumper setting refer to Section 4 The card is pre set as LPT2 port address 0278h As most PCs only have a printer interface LPT1 this setting generally does not pose any problems If two LPT interfaces are already available one of these must be removed or re configured to an alternative address as the CENTRONICS plug in card supplied only permits the LPT1 LPT2 settings Install the CENTRONICS card and retain it on the slot panel with the screw provided Insert the 25 pin SUB D connector of the ribbon cable into the CENTRONICS card socket Insert the other end into the parallel programmer Retain the ribbon cable using a cable tie Establish the parallel programmer power supply If your PC power supply still has a free connection for peripheral devices then this can be used Otherwise you must disconnect a floppy drive 5 or a hard disk from the power supply Attach the supplied V piece to the free power supply connector Then connect the parallel programmer and the floppy or hard disk to the PC power supply through the V piece Close up your PC Siemens AG 465 982 7102 01 Edition 05 95 Fehler Nur Hauptdokument 5 SIMADYN D Parallel Programmer User Manual 1 Introduction 1 2 2 External version MLFB 6DD1672 0ADO Code PP1X Item No 634 691 1 2 2 1 Scope of supply parallel programmer in a metal enclosure SUB D 25 core cable socket connector plug connector line supply cable

Download Pdf Manuals

image

Related Search

Related Contents

Daily Physical Activity Student User Manual  Eureka AS4008A Use and Care Manual  User Manual - iBaby Labs  southernmost hog miami, florida chapter newsletter  Garmin Software Version 0719.12 Cockpit Reference Guide  取扱説明書等 - アイ・オー・データ機器  Goodada Seller User Manual  一般仕様書(PDF:521KB)  Hotpoint AQ113D User's Manual  SMT319 User Manual - Sundance Multiprocessor Technology Ltd.  