Quick Installation Guide - ao
Contents
1. A Configuration Card User Access Cards PINS Configuration Card again to end task 4 The first card read becomes the Configuration Card and the following RF Cards PINs are registered as User Access Cards with assigned PINs Once all User Access Cards and PINS have been registered present the Configuration Card again to complete the registration Please keep the Configuration Card in a secure location for future changes 5 Now the Main Unit is entered into the normal operation mode with factory defaulted settings 7 3 Registration of PIN ONLY MODE 1 Apply 12V DC to the unit All 3 LEDs will be flashing along with a powered up melody do mi sol me do do mi sol do 2 Press 0 3 EN from the keypad PIN ONLY MODE 3 Enter to register Configuration PIN then to register for each subsequent User Access PIN at a time and then enter the Configuration PIN to complete the registration 4 6 digit PIN 4 6 digit PIN JENT 4 6 digit PIN Configuration PIN User Access PIN Configuration PIN again to complete the registration 4 The first 4 6 digit PIN becomes the Configuration PIN and the subsequent 4 6 digit PINs are registered as User Access PINs Once all User Access PINs have been registered enter the Configuration PIN again to complete the registration Please store the Configuration PIN for future changes Jun 2011 Copyright IDTECK Co Ltd Quick Installation Guide 5 Now the Main Unit is entered into
2. the 100R and higher V3 0 0 of the IP100R and higher Figure The Position of SW1 and SW2 to generate Weigand Output Format Orange wire with White Brown wire with stripe White stripe ON ON TTL Output Chime Bell Output When the Wiegand Output function is used TTL Output wire is changed to Wiegand Data 0 and Chime Bell Output wire to Wiegand Data 1 Output wire Therefore you can t use those functions In addition because TTL Output wire is changed to Wiegand Data 0 Output you can t initialize the 100W IP100W using the wires You can use those functions again when setting SW1 and SW2 to the default state Jun 2011 Copyright O IDTECK Co Ltd Quick Installation Guide 6 SYSTEM WIRING FOR TYPICAL APPLICATION Star 100 EXIT Orange LS EXIT Lia BUTTON DOOR ei I ith Red ellow with Red ES CONTACT f a INPUT CHIME RES Sc ALARM DOOR RELAY RELAY COM PIR SENSOR COM White DOOR ALARM RELAY N g RELAY White with Ne ss CHIME BELL Red Purple ac 12V GND O DC 12V POWER SUPPLY DOOR LOCK Figure System Wiring Example 6 1 Power Connection Connect wire of DC 12V power to Red wire Connect Power GND wire of DC 12V to Black wire 6 2 Door Lock Connection 6 2 1 Connection of POWER FAIL SAFE Door Lock Connect Door RELAY COM Grey with Red stripe wire to DC 12V be sure that the existing power supply has enough c
3. the normal operation mode with factory defaulted settings 7 4 Registration of RF PIN Combination MODE 1 Apply 12V DC to the unit All 3 LEDs will be flashing with a power up melody Press 0 5 Je from the keypad RF PIN Combination Mode Present Configuration Card to register Configuration Card to the unit Present RF Card or enter 4 6 digit PIN number to register user access card or PIN Present Configuration Card to complete the registration 2 3 4 5 gt o_o amp SSOO Configuration Card or or or Configuration Card PIN PIN PIN 7 5 Factory Defaulted Setting Values After the Initial Setup the Main Unit uses the factory defaulted setting values below to execute the normal operation mode You may want to change these factory setting values or modify your User Access list refer to section 12 of the main manual for instructions on how to customize the operation of your unit GEILO3 sS 2 When User Access Card or PIN is not recognized Alarm RELAY activates for 2sec gt B 02 S Red LED lights on for 2sec 1 When User Access Card or PIN is granted Door RELAY activates for 3sec Green LED lights on for 3sec 3 Duress Password 00 Duress Alarm to TTL output port for 03 sec 4 QUICK ACCESS MODE Disable 5 Chime Bell output Enable Chime Bell activation time 05 sec 6 Melody sound Enable 7 Keypad lock out time when Try Out error detected 01 min 8 Detect al
4. to Secure Mode by entering the Secure Code of onto the keypad Change to Secure Mode Jun 2011 Copyright O IDTECK Co Ltd Quick Installation Guide The Secure Mode will revert back to the normal mode when a registered card or PIN is presented entered 8 6 DURESS Alarm e w ENT In case of Duress enter the 2 digit Duress Password and the door will open as usual however the Duress Alarm TTL Output will activate an external Auto Dialer to notify the appropriate personnel See section 9 7 and 12 29 of the main manual for more instructions on this feature 8 Chime Bell Operation The key can be used to activate an external Chime Bell for 5 seconds the defaulted value Jun 2011 Copyright O IDTECK Co Ltd Quick Installation Guide 9 INITIALIZATION When you lost the Configuration Card or forget the Master PIN number you may need to re initialize the unit for new setup There is a hard wired Initialize function on the unit Xx WARNING You may lose all setup data after Initialization 9 1 Hardware Initialization When the master card or ID is lost 1 Open the top case taking out four bolts on the back 2 As the left picture make two jumpers short in state of being on power 3 3 color LED blinking with beep sound indicates success of initialization 9 2 Wire Initialization _ When the master card or ID is lost 100R Over V5 0 0 IP100R Over V2 0 0 GND Green Orange with Wh
5. 12V be sure that the existing power supply has enough capacity to support this accessory or upgrade to a sufficient one Connect wire of Reader to Power GND wire Connect Wiegand output DATAO wire of the additional Reader to DATAO Pink wire Connect Wiegand output DATA1 wire of the additional Reader to DATA1 Cyan wire 6 9 RS 232 Communication Port Connection 9 pin connector COM Port female is required to connect serial communication RS 232 between Main Unit and Personal Computer Connect RS 232 TX Black with White stripe wire of Main Unit to pin number 2 of 9 pin connector Connect RS 232 RX Red with White stripe wire of Main Unit to pin number 3 of 9 pin connector Connect RS 232 GND Black wire of Main Unit to pin number 5 of 9 pin connector Plug in 9 pin connector to COM1 or COM2 Port of Personal Computer Install and run STAR 100R Application Software 6 10 Chime Bell Connection Separate purchase required Connect wire of Chime Bell unit to Bell Output Brown with White stripe wire of Main Unit Connect wire of Chime Bell unit to Power GND wire 7 INITIAL SETUP The Flash memory of each shipped STAR 100R contains a minimum set of defaulted values but it does not have any other preprogrammed values or user s data in it therefore Initial Setup is required upon the first time the unit is powered up in order to operate the unit properly 7 1 Registration of RF Cards for RF CARD
6. ND wire If a normally closed Door Contact sensor is used then see section 12 57 of the main manual to change the detection scheme from the defaulted setting 6 6 Auxiliary Input Device Connection Applied to AUX Input 1 2 3 Connect one wire of the Auxiliary Input Device to the AUX Input wire Input 1 Green Input 2 Green with White stripe Input 3 Green with Red stripe wire Connect the other wire of Auxiliary Input Device to Power GND wire If a normally closed input device is used then see section 12 49 51 amp 53 of the main manual to change the detection schemes from the defaulted settings 6 7 Auto Dialer Connection Separate purchase required The Auto dialer function of this unit has not been evaluated by UL Connect the input wire of Auto Dialer to TTL output Orange with White stripe wire Connect wire of Auto Dialer to DC 12V be sure that the existing power supply has enough capacity to support this accessory or upgrade to a sufficient one Connect wire of Auto Dialer to Power GND wire Connect Telephone Line plug RJ 14 to Auto Dialer If an active High Auto Dialer is used then see section 12 59 of the main manual to change the TTL output level from the defaulted setting Jun 2011 Copyright O IDTECK Co Ltd Quick Installation Guide 6 8 Wiegand Input Connection from Another Compatible Wiegand Reader Separate purchase required Connect wire of Reader to DC
7. ONLY MODE 1 Apply 12V DC to the unit All 3 LEDs will be flashing along with a powered up melody do mi sol me do do mi sol do 2 Press 0 1 Ewr from the keypad RF CARD ONLY MODE 3 Present RF Cards as follow to register Configuration Card and User Access Cards A Configuration Card User Access Cards Configuration Card again to end task X NOTE The user may choose to register the 8 digit card numbers via the keypad instead of presenting the cards to the unit this implies that the user must know the 8 Jun 2011 Copyright O IDTECK Co Ltd Quick Installation Guide digit representation of each card 4 The first card read becomes the Configuration Card and the following RF Cards are registered as User Access Cards Once all User Access Cards have been registered present the Configuration Card again to complete the registration Please keep the Configuration Card in a secure location for future changes 5 Now the Main Unit is entered into the normal operation mode with factory defaulted settings 7 2 Registration of RF Cards with PINs for RF CARD PIN MODE 1 Apply 12 V DC to the unit All 3 LEDs will be flashing along with a powered up melody do mi sol me do do mi sol do 2 Press 0 J 2 JEnr from the keypad RF CARD PIN MODE 3 Present RF Cards as follow to register Configuration Card and User Access Cards 4 6 digit Personal Identification Number PIN for each User Access Card
8. Quick Installation Guide Star 100R iPASS P100R Star 100R Quick Installation Guide 1 IMPORTANT SAFETY INSTRUCTIONS The description below is to keep user s safety and prevent any product damage Please fully read these instruction and use the product properly Danger This symbol indicates that incorrect handling of the product may result in serious injury or death Warning This symbol indicates that incorrect handling of the product may result in injury or property damage Cautions about Power Only use the standard voltage DC 12V 350mA If the product emits smoke or smells stop using the product Unplug the product from DC power source and contact nearest service center A Cautions about Installation Do not install the product in humid dust metallic dust and sooty place Do not install the product in a place subject to high or low temperature and high humidity Do not install the product with tools such as driver in hand when power has been supplied A Cautions about Usage Do not drop liquid like water and give a shock severely Do not place magnetic objects near the product Do not replace the wiring cables installed by experts Do not use the product near direct sunlight and heating apparatus If you want to relocate the installed product turn power off and then move and reinstall it Do not use the product near flammable spray or objects Do not disassemble repair or m
9. apacity to support this accessory or upgrade to a sufficient one Connect wire of Door Lock to Door RELAY NC Blue with White stripe wire Connect wire of Door Lock to Power GND wire 6 2 2 Connection of POWER FAIL SECURE Door Lock Connect Door RELAY COM Grey with Red stripe wire to DC 12V be sure that the existing Jun 2011 Copyright IDTECK Co Ltd Quick Installation Guide power supply has enough capacity to support this accessory or upgrade to a sufficient one Connect wire of Door Lock to Door RELAY NO White with Red stripe wire Connect wire of Door Lock to Power GND wire 6 3 Alarm Device Connection Connect Alarm RELAY COM White wire to DC 12V be sure that the existing power supply has enough capacity to support this accessory or upgrade to a sufficient one Connect wire of Alarm Device to Alarm RELAY NO Purple wire Connect wire of Alarm Device to Power GND wire 6 4 Exit Button Connection Connect one of the wires of Exit Button to Exit Button Input Orange wire Connect the other wire of Exit Button to Power GND wire If a normally closed Exit button is used then see section 12 55 of the main manual to change the detection scheme from the defaulted setting 6 5 Door Contact Sensor Connection Connect Door Contact sensor COM wire to Door Contact Input Yellow with Red stripe wire Connect Door Contact sensor NO wire to Power G
10. ite stripe short 1 Main power off 2 Connect the Green and orange with white stripe wire together and power on 3 3 color LED blinking with beep sound indicates the success of initialization 100R V5 0 0 V5 0 3 IP100R V2 0 0 V2 0 1 4 Main power off again 5 Disconnect orange wire and orange with white stripe wire as shown above normal connection diagram and power on Green Orange with White stripe 100R Over V5 0 4 IP100R Over V2 0 2 4 Disconnect those two wires and wire them as shown above normal connection diagram Jun 2011 Copyright O IDTECK Co Ltd Quick Installation Guide 10 Template Jun 2011 Copyright O IDTECK Co Ltd
11. l inputs from H to L 9 Activate TTL output to L 10 Delay time to activate SECURE MODE 00 min 11 Door Open time out for Door Contact sensor 00 sec 12 Number of times of Try out 05 times 13 Input keypress time out time 20 sec Jun 2011 Copyright IDTECK Co Ltd Quick Installation Guide 14 Tamper Alarm Disable Tamper Alarm output port 02 Alarm Relay 15 Toggle Mode Disable 16 Unlock followed by Door Contact Disable 9 OPERATION 9 1 Normal Operation Mode Safe Mode When the Main Unit operates in normal mode the yellow LED is flashing every second 8 2 Open the Door When a registered Card or PIN is read the Door will open for 3 seconds along with the do mi sol do melody GOS S Registered Card or PIN 9 3 Exit Open the Door hs To request for exit from the inside an Exit Button can be used to open the door for the same duration as in 11 2 sm MAOZ S 8 4 Action and Alarm Caused by Unregistered Card or PIN When an unregistered Card or PIN is read thus access is denied and the Alarm can be activated for 2 seconds along with sol do sol do melody A AB S Unregistered Card or PIN If you do not want to activate the Alarm in case of unregistered access attempt then you can change this setting as shown in section 12 8 5 Secure Mode The last person to exit can change the operation of the unit from Normal Mode
12. mm 2 Using 2 screws install wall mount to the wall Xx CAUTIONS Before mounting the STAR 100R unit to the Wall Mount bracket operational testing of the unit should be completed as the locking pins will lock the unit to the Wall Mount Removing the unit from the Wall Mount bracket after they have been installed together may cause damages to the bracket and render its effectiveness 2 Insert 5 O rings to the wall mount as indicated then route the cable of the main unit through the center hole and push the main unit to wall mount to lock the main unit and make sure that the main unit is locked with wall mount Jun 2011 Copyright IDTECK Co Ltd Quick Installation Guide 9 WIRING COLOR TABLE A 2PIN 41 IA MainPower 12V DC 12V Rd J2 IN AAA Door Relay NC NC 1 Blue with White Stripe IN 0 OS RESERVED __ BluewithRedStripe _ E E E EC EE ne DO TT Pp RS232 RX RXD Red with White Stripe Jun 2011 Copyright IDTECK Co Ltd Quick Installation Guide Optional Wiegand Output Function The default output format of 100R IP100R is TTL and Chime Bell output But you can configure the 100R IP100R to generate output in Wiegand format and use it like a reader The 100R IP100R can output data from card reading but can t output data from keypad input If you want to generate Wiegand instead of TTL output format follow the table below This function is only applicable to V6 0 0 of
13. odify the product by yourself If the product needs service or repair contact nearest service center If liquid has been spilled on the product unplug it and contact nearest service center A Cautions about Cleaning Do not clean the product with water Clean gently with dry cloth or tower Do not use chemicals such as benzene thinner or acetone for cleaning Jun 2011 Copyright IDTECK Co Ltd Quick Installation Guide 2 IDENTIFYING SUPPLIED PARTS Please unpack and check the contents of the box Uere y Marre Star 100R Star 100R o 0 0 o Main Unit Wall Mount O Ring User s Manual 1ea 1ea 5ea 1copy Master Card Star 100 m 3 5 40 Screw 3 5 12Screw Anchor Bolt Cable amp Diode Master Card 4ea 4ea 4ea Cable 4 ea Diode 2 ea 1ea 3 FRONT PANEL DESCRIPTION Star 100R LED SRE Display Eo Figure Front Panel Jun 2011 Copyright O IDTECK Co Ltd Quick Installation Guide 4 INSTALLATION 1 Tear off page on the back this manual and use the provided template to drill two 6 32 holes and one 1 2 hole on the proper location of the wall to mount the Wall Mount bracket as shown below If the gang box is already installed on the wall then skip this step 6 32 hole ye m 0 O ring 1 18 30mm J 1 55 39 5mm gt ee co ro cr 2 1 79 45 5mm E et wi n a a 1 52 38 5mm 1 52 38 5mm 3 03 77
Download Pdf Manuals
Related Search
Related Contents
Installation & User Manual Radio Remote RC-10E - Side PNY P-TSAL1-RB Belkin F1DN116C KVM switch Antec Sonata Designer 500 Sharp PC-E500 Service Manual - PC Whirlpool AKR 311/IX 11 Conservação e manutenção Graveur CD-RW Professional MANUAL DE INSTRUCCIONES 取扱説明書 - TOEX Copyright © All rights reserved.