1. 1 Features 1 Analog Inputs 1 Digital Inputs 1 Software 1 WinDaq Recording and Playback Software 1 The DATAQ Instruments Hardware Manager 2 Help 2 2 Specifications 3 Analog Inputs 3 Digital Inputs
2. 3 Reserved Inputs Digital Inputs 3 ADC Characteristics 3 Indicators and Connections 3 Power 4 Environmental 4 Physical Characteristics 4 Software Support 4 3 Installation 5 Installing WinDaq Software and the DATAQ Instruments Hardware Manager 5 Connecting the Instrument to Your Computer 6 DA
3. You may burn the executable onto a CD to transport the software to a computer with no internet connection 1 Disconnect all DATAQ Instruments USB devices from your Computer 2 Go to run dataq com in your web browser 3 Click on the WinDaq Software link requires subscription 4 Sign up for our newsletter to receive the download link you can opt out after download 5 Double click on the downloaded file to extract the program and begin software installation 6 Follow the on screen prompts and enter any required information DI 145 Hardware Manual Installation 6 7 Software installation is complete you will now see a Successful Installation box click OK to exit WINDAQ Installation You can now plug the device s into your PC Click on the appropriate program group specified above default is Start gt Programs gt WINDAQ and click on DATAQ Instruments Hardware Manager to access WINDAQ software Connecting the Instrument to Your Computer DI 145 instruments can be connected to your computer s USB port using the provided USB cable No external power is required Connect one end of the communications cable to the instrument port and the other to your PC s port Note Use a powered USB hub or a USB port on your PC Non powered USB hubs may not have sufficient power to run the instrument DATAQ Instruments Hardware Manager The DATAQ Instruments Hardware Manager is installed when installing
4. Block Diagram 15 6 Dimensional Drawing 17 DI 145 Hardware Manual Introduction 1 1 Introduction This manual contains information designed to familiarize you with the features and functions of the DI 145 USB data acquisition starter kit These high end Starter kits contain features and functionality normally reserved for more expensive data acquisition systems Features The DI 145 data acquisition instrument is a portable data recording module that communicates through your com puter s USB port Power is derived from the interface port so no external power is required Features include 4 fixed differential analog inputs protected to 150V transient Two dedicated digital I O ports for Remote control protected to 30V 10V full scale measurement range 240 samples per second maximum sampling rate A push button to tag remote events in WINDAQ software Three status LEDs for easy notification of system status Backwards compatible with the DI 194RS serial port data acquisition system protocol Analog Inputs The DI 145 features four differential channel inputs located on a single sixteen position screw terminal block for easy connection and operatio
5. Record Remote Control Shunt Resistor Model R250 DI 145 Hardware Manual Controls Indicators and Connections 12 The shunt resistor should be placed on the low side of the circuit as shown below Set the engineering units as desired and define upper lower levels in WINDAQ as 1V 4mA for the low value and 5V 20mA for the high value For example when using WINDAQ Acquisition software in the EU Settings dialog box Enter the following values You can also associate these values to a physical measurement such as pressure load flow torque etc Read the Help files for more information regarding Engineering Units Settings LED Indicators The DI 145 provides three green LEDs for instrument status and notification Power Indicates power is applied via the USB cable Active Indicates the device is in use either by WINDAQ Acquisition Software or a custom user developed program Remote Indicates when the Event Button is pushed or the Event terminals are connected via a relay contact or digital input Volt EU EU Tag Upper Level 5 20 mA Lower Level 1 4 Shunt Resistor I 4 20mA Current Loop Transmitter Loop Power Supply To DI 145 Analog Input Channel DI 145 Hardware Manual Block Diagram 13 5 DI 145 Block Diagram 10 160K 1M 1M 0 1 EEPROM Calibration Model Serial SPI Port AVR32 CPU ADC USB General Purpose I O General Purpose I O ATM
6. Reserved Event Record Remote Control Please note The SD card slot is not used in the DI 145 Allowing foreign materials to enter the device through the SD card slot may result in damage to the instrument Mini B USB Connection Use the supplied USB cable to connect and power the instrument through your computer s USB port Connecting Input Signals All input signal connections are made to the 16 port screw terminals Each terminal is labeled directly on the instru ment case DI 145 Signal Connections Refer to the following for screw terminal port identification Ch Analog channels 1 4 10VFS 150V transient Max Remote Control Event Digital Input bit 0 Remote Event Marker Remote Control Record Digital Input bit 1 Remote Start Stop Reserved NC No connection reserved www dataq com Power Remote Active Ch1 Ch2 Ch3 Ch4 Model DI 145 Data Acquisition Starter Kit Analog Inputs 10 VFS 150 V max Event Download software at dataq com 145 Event Record Remote Control Reserved DI 145 Hardware Manual Controls Indicators and Connections 8 Use the following diagram to connect Analog Input Channel 1 Connecting Signal Leads To connect signal leads to the DI 145 1 Insert the stripped end of a signal lead into the desired terminal directly under the screw 2 Tighten the pressure flap by rotating the
7. sample rate of the DI 145 240Hz maximum throughput DI 145 Hardware Manual Introduction 2 WINDAQ Waveform Browser playback software also known as WWB offers an easy way to review and analyze acquired waveforms A built in data file translator allows the user to display multiple waveforms acquired by WINDAQ Acquisition software or any of a wide range of data acquisition packages The software s disk streaming design allows data files of any length to be graphically displayed rapidly in normal or reverse time directions Seven standard cursor based measurements frequency domain and statistical analysis functions help simplify waveform analysis and interpretation WINDAQ Waveform Browser is free and installed when installing WINDAQ Software The DATAQ Instruments Hardware Manager This software can be found in the Start menu under the WINDAQ program group called DATAQ Instruments Hard ware Manager Access WINDAQ Acquisition software and manage multiple DATAQ Instruments devices in this easy to use point and click environment View the Help files by clicking on View Help in the Help menu or by press ing F1 Help All WINDAQ software utilizes context sensitive help Help may be accessed through the Help menu or by pressing the F1 key with any pull down menu item selected This will take you directly to the Help topic most relevant to that par ticular function or feature Help topics discuss in detail each function available in the softw
8. screw clockwise with a small screwdriver Make sure that the pressure flap tightens only against the signal wire and not the wire insulation Do not over tighten 3 Tug gently on the signal lead to ensure that it is firmly secured When an input signal is connected and WINDAQ Acquisition software is run WINDAQ s real time display immedi ately reveals the input waveform on your computer s monitor www dataq com Power Remote Active Ch1 Ch2 Ch3 Ch4 Model DI 145 Data Acquisition Starter Kit Analog inputs 10 VFS 150 V max Event Signal Signal Download software at dataq com 145 Event Record Remote Control Reserved DI 145 Hardware Manual Controls Indicators and Connections 9 WINDAQ Remote Controls Digital Inputs The DI 145 contains 2 digital inputs for WINDAQ Remote Events inserts an Event Marker and Remote Storage Record data Valid remote record and event signals are switch closures or discrete levels with a maximum input of 30 V and a threshold of 1 8 V WINDAQ Remote Events To use a switch closure or TTL signal to record WINDAQ Event Markers connect signal leads to the appropriate Remote Control Event terminals on the DI 145 as shown below Once the switch closure or TTL signal is connected activate Remote Events through WINDAQ Acquisition Software Events may be automatically placed on the rising or falling edge of the trigg
9. EL Microcontroller Panel Panel Analog In Typical 4 places AIN1 AIN2 AIN3 AIN4 DIN0 DIN1 Analog In 2 Analog In 3 Analog In 4 Digital In 0 Remote Events Remote Start Stop V USB V Reg V VBus Power Active Remote V Event 0 01 160K 4 7K 47K 47K V VBias VCC Digital In Typical 2 places 0 01 100p DI 145 Hardware Manual Dimensional Drawing 15 6 Dimensional Drawing 1 612 5 500 4 750 4 250 0 750 2 625 DATAQ Instruments Inc 241 Springside Drive Akron Ohio 44333 Telephone 330 668 1444 Fax 330 666 5434 E mail support dataq com Direct Product Links click on text to jump to page Data Acquisition Data Logger
10. T h e w a y P C b a s e d i n s t r u m e n t a t i o n s h o u l d b e DI 145 4 Channel USB Data Acquisition Starter Kit User s Manual Manual Revision E Copyright 2014 by DATAQ Instruments Inc The Information contained herein is the exclusive property of DATAQ Instruments Inc except as otherwise indicated and shall not be reproduced transmitted transcribed stored in a retrieval system or translated into any human or computer language in any form or by any means electronic mechanical magnetic optical chemical manual or otherwise without expressed written authorization from the com pany The distribution of this material outside the company may occur only as authorized by the company in writing DATAQ Instruments hardware and software products are not designed to be used in the diagnosis and treatment of humans nor are they to be used as critical components in any life support systems whose failure to perform can rea sonably be expected to cause significant injury to humans DATAQ the DATAQ logo and WINDAQ are registered trademarks of DATAQ Instruments Inc All rights reserved DATAQ Instruments Inc 241 Springside Drive Akron Ohio 44333 U S A Telephone 330 668 1444 Fax 330 666 5434 Designed and manufactured in the United States of America iii Warranty and Service Policy Product Warranty DATAQ Instruments Inc warrants that this hardware will be free from defects in materials and workmanship under
11. TAQ Instruments Hardware Manager 6 4 Controls Indicators and Connections 7 Mini B USB Connection 7 Connecting Input Signals 7 DI 145 Signal Connections 7 Connecting Signal Leads 8 WinDaq Remote Controls Digital Inputs 9 WinDaq Remote Events 9 WinDaq Remote Storage Record 11 4 20mA Current Loop Measurements 11 LED Indicators 12 5 DI 145
12. any DI 145 instrument This software allows you to effectively manage multiple devices installed on the same PC The DATAQ Instruments Hardware Manager may be accessed through the Windows Program Manager Group as specified during installation default is Start gt Programs gt WINDAQ gt DATAQ Instruments Hardware Manager All available devices will automatically appear in the list box when you run the software The Hardware Manager allows you to start WINDAQ Acquisition software select the device and click on the Start Windaq button and must be used when multiple DATAQ Instruments devices are installed It also provides crucial information about your device needed for custom programming Serial and COM Port Please note The description of DI 145 models cannot be modified Click on the Help button for help with the DATAQ Instruments Hardware Manager DI 145 Hardware Manual Controls Indicators and Connections 7 4 Controls Indicators and Connections www dataq com Power Remote Active Ch1 Ch2 Ch3 Ch4 Model DI 145 Data Acquisition Starter Kit Analog inputs 10 VFS 150 V max Event Analog In Channels 1 4 Reserved no connection Digital In Channels Power Active and Remote LEDs Event Marker Push Button Mini B USB Connection SD Card Slot not used in DI 145 Bulkhead Mounting Ear Bulkhead Mounting Ear Download software at dataq com 145
13. are DI 145 Hardware Manual Specifications 3 2 Specifications Analog Inputs Number of Channels 4 Channel Configuration Differential Voltage Measurement Range 10V Full Scale Input Impedance 1M each input to ground Isolation none Accuracy 0 25 of FSR Overall inaccuracy 64mV at 25 C DC common mode rejection 40 db at 25 C Max input without damage 75 V peak continuous 150 V peak one minute or less Max common mode voltage 10V Analog frequency response 3db 100 Hz Digital Inputs Number of Channels 2 Pull up value 47 K from input to to 3 3V Pull down value 4 7 K from input to USB ground Input high voltage threshold 1 8 V minimum Input low voltage threshold 1 4 V maximum Absolute maximum values 30 VDC Reserved Inputs Digital Inputs Digital In 0 WINDAQ remote start stop Digital In 1 WINDAQ remote events ADC Characteristics Resolution Overall 1 part in 1 024 10 bit Above zero 1 part in 511 Below zero 1 part in 512 1 ADC Count 19 5 mV Max sample throughput rate 240 Hz Min sample throughput rate 0 44 samples per minute Sample rate timing accuracy 50 ppm Indicators and Connections Interface USB 2 0 mini B style connector Indicators LED Power Active Digital Input Connections One 16 position terminal strip DI 145 Hardware Manual Specifications 4 Power Power Consump
14. emote Control DI 145 Hardware Manual Controls Indicators and Connections 11 WINDAQ Remote Storage Record To use a switch closure or TTL signal to begin recording data remotely connect signal leads to the appropriate Remote Control Record terminals on the DI 145 as shown below Once the switch closure or TTL signal is connected activate Remote Storage Record through WINDAQ Acquisition Software Storage to Disk may be automatically placed on the rising or falling edge of the trigger signal Use the menu command Options gt Remote Storage 1 to set WINDAQ to begin recording on low to high transitions of the Record input Use the menu command Options gt Remote Storage 0 to set WINDAQ to begin recording on high to low transitions of the Record input 4 20mA Current Loop Measurements Use the following diagram for 4 20mA current loop measurement connections Signal Signal www dataq com Power Remote Active Ch1 Ch2 Ch3 Ch4 Model DI 145 Data Acquisition Starter Kit Analog Inputs 10 VFS 150 V max Event Download software at dataq com 145 Event Record Remote Control Reserved www dataq com Power Remote Active Ch1 Ch2 Ch3 Ch4 Model DI 145 Data Acquisition Starter Kit Analog inputs 10 VFS 150 V max Event Download software at dataq com 145 Reserved Event
15. er signal Use the menu command Options gt Remote Events to set WINDAQ to place event markers on low to high transitions of the Event input Use the menu command Options gt Remote Events to set WINDAQ to place event markers on high to low transi tions of the Event input Switch Closure TTL 0V 30V Max 1 8V Threshold www dataq com Power Remote Active Ch1 Ch2 Ch3 Ch4 Model DI 145 Data Acquisition Starter Kit Analog inputs 10 VFS 150 V max Reserved Event Signal Signal Download software at dataq com 145 Event Record Remote Control DI 145 Hardware Manual Controls Indicators and Connections 10 Event markers may also be placed in your data file manually by pressing the push button on the DI 145 Instrument You must enable Remote Events in WINDAQ to use the button use the menu command Options gt Remote Events or Options gt Remote Events An example event marker in a WINDAQ data file is shown below Please Note Event Markers do not display in the real time WINDAQ acquisition software they only display in the WINDAQ playback software WWB www dataq com Power Remote Active Ch1 Ch2 Ch3 Ch4 Model DI 145 Data Acquisition Starter Kit Analog inputs 10 VFS 150 V max Reserved Event Download software at dataq com 145 Event Record R
16. n other terminals used for digital I O or reserved Note The DI 145 does not support Gain Utilize the functionality of WINDAQ software to experience all the features encased in these small inexpensive instruments Digital Inputs The DI 145 contains two digital lines bits for WINDAQ remote control operations Remote Start Stop and Remote Events Connect switch closures or discrete levels with a maximum input of 30V and a threshold of 1 8V The inputs float at 1 level about 3 3V relative to the terminal and require sinking about 50uA to bring them down to 0 8V and guarantee a 0 When no Options Remote are enabled in WINDAQ the Event input appears inverted in data bit 0 and the Record input appears inverted in data bit 1 of data for the first enabled channel Software All software required to record and playback waveforms is included with the purchase of any DI 145 data acquisition starter kit via download WINDAQ Recording and Playback Software WINDAQ Acquisition and WINDAQ Waveform Browser allow you to record and playback data acquired through your instrument WINDAQ software is an invaluable resource to record and analyze your data and is available for free from our web site www dataq com WINDAQ Acquisition software can be used to record waveforms directly and continuously to disk while monitoring a real time display of the waveforms on screen It operates displays and records waveform signals in real time at the full
17. normal use and service for a period of 90 days from the date of shipment DATAQ Instruments obligations under this warranty shall not arise until the defective material is shipped freight prepaid to DATAQ Instruments The only responsibility of DATAQ Instruments under this warranty is to repair or replace at its discretion and on a free of charge basis the defective material This warranty does not extend to products that have been repaired or altered by persons other than DATAQ Instru ments employees or products that have been subjected to misuse neglect improper installation or accident DATAQ Instruments shall have no liability for incidental or consequential damages of any kind arising out of the sale installation or use of its products Service Policy 1 All products returned to DATAQ Instruments for service regardless of warranty status must be on a freight pre paid basis 2 DATAQ Instruments will repair or replace any defective product within 5 days of its receipt 3 For in warranty repairs DATAQ Instruments will return repaired items to the buyer freight prepaid Out of war ranty repairs will be returned with freight prepaid and added to the service invoice DI 145 Hardware Manual Table of Contents vii Table of Contents Warranty and Service Policy iii 1 Introduction
18. tion 0 30 watts via USB interface Environmental Operating Temperature 0 C to 35 C 32 F to 95 F Operating Humidity 0 to 90 non condensing Storage Temperature 20 C to 45 C 4 F to 113 F Storage Humidity 0 to 90 non condensing Physical Characteristics Enclosure Hardened Plastic Mounting Desktop bulkhead Dimensions 2 625D 5 5W 1 53H in 6 67D 13 97W 3 89H cm Weight 3 6 oz Software Support WINDAQ software OS support Check Online Sample Rate Limit 240 Hz Backwards compatibility DI 194RS compatibility mode supports Linux and MatLab Programming DATAQ Instruments SDK DI 145 Hardware Manual Installation 5 3 Installation The following items are included with each WINDAQ Starter Kit Verify that you have the following A DI 145 USB data acquisition instrument USB cable A DATAQ Instruments screwdriver for signal lead connections If an item is missing or damaged call DATAQ Instruments at 330 668 1444 We will guide you through the appropri ate steps for replacing missing or damaged items Save the original packing material in the unlikely event that your unit must for any reason be sent back to DATAQ Instruments Installing WINDAQ Software and the DATAQ Instruments Hardware Manager All software for the DI 145 can be installed via a downloadable executable directly from the DATAQ Instruments web site No CD is shipped with the device

Download Pdf Manuals