1. ENVIRONMENT Edit SAVE TO SCENE Scene save key SAVET EDIT SAVETO Save the current channel values ofthe scanners to a scene with O O O _ pomere aD some number Set the channel values of various scanners with manual operation or O add some scenes then press the key first and press scene section ed key and scene number key The current channel values of the SeTXIY ENTER SWITCH scanners are saved to the number of that section EDIT CHASE Chase edit key Press the key the indicating light blink It isin the chase edit state Press the key again the indicating light is off The edit resultis saved and the edit state is quitted SAVE TO ENV Environmentsave key Press the key then press environment number key the environmentis saved to the number of environment SET X Y X Y set key Write the X Y control channel number of various scanners to the console then use modulation wheel to control the position of the various scanners DELETE Delete key When the chase is edited press the key to delete the currentchase step ADD Add key When the chase is edited press the key to add
2. o n SCENE 512 console can save 48 scenesin 3 saving section with 16 scenes each A B C Scene section key When the key is pressed the corresponding indicating light is on and indicates thatthe sectionis current section If current section is A press scene number key and A01 A16 scene can be operated If the indicating light of not current section ison itindicates thatthere are scenes are running in that section O0 00 00 00 SINGLE Single scene key Set for each section respectively The keyis used to switch the following states When SINGLE light is on the current section only can run a scenes When SINGLE light is off the current section can run multi scenes at the same time 1 16 Scene number key Cooperating with scene section key 16 scene keys can operate A01 A16 BO1 B16 C01 C16 48 scenes Using SINGLE key single scene or multi scenes can be operated CHASE 512 console can save 48 chasesin 3 saving section with 16 chases each A B C Key O0 O 00 0
3. When the key is pressed the corresponding indicating light ison and indicates thatthe section is current section If current section is A press scene number key and A01 A16 chase can be operated If the indicating light of not current section is on itindicates thatthere are chases are running in that section O 0O O00 OW USER MANUAL 5 17 DMX 512 CONTROLLER SERIES o SINGLE Single chase key The keyis used to switch the following states When SINGLE light is on the current section only can run a chase When SINGLE light is off the current section can run up to 4 chases at the same time The key is effective for 3 chase sections 1 16 Chase number key Cooperating with chase section key 16 chase keys can operate A01 A16 BO1 B16 C01 C16 48 chases Using SINGLE key single chase or multi chases can be operated ENVIRONMENT mE O 00 00 00 SELECT Environmentchoice key Press the key first then press the environment number key the environment can be runor stopped 11 115 Environment number key At anytime only one environmentcan be chosen Q0 00 0 09
4. Trigger mode selectable Music synchronously and manual speed Cooperating with the chase speed slider the time ofthe program step can be changed from 0 03s to 180s 48 scanner scenes canbe used directly 4 chases 48 scenes operated atthe sametime At most 32 scanners can be selected simultaneously The X Y channels of different scanners can be controlled by modulation wheel 16Bit control for absolutely precise movement 15 environment programs to output the combination which are composed of different scenes chases and manual output quickly The musictrigger source can be selected between audio line input orinside microphone Easy to edit and handle The Data auto saves High performance switching power supply with extremely low power harmonious distortion and wide range of voltage suit for the requirement of different country Explanation for Reading For reading convenience some signs and usual displays are specially defined as following xxx expresses a keylike HOLD When the parameter is inside ondisplaylike 012 the parameter is the current choice Press xx yy expresses press xx key first and holdthen press yy key X Y controlis named Pan Tilt also In the Manual itis X y the control of X axis Y axis When the key indicating light is on itindicates that the key has been pressed chosen or the function is effective When the indicating lightis blink BLACKOUT EDIT function key emphasizes the function
5. Scanner number key expresses that the computer isin ahold state Scene section key and chase section key aindicat that when multi scenes and multi chases are running there are scene or chase running onthe section USER MANUAL 1 17 DMX 512 CONTROLLER SERIES O Cautions Danger there is high voltage inside the equipment avoid getting an electric shock Caution please don t openthe equipment There is no part that can be repaired by the user Using the equipment the power supply must be connected tothe earth line to ensure the safety When console and scanner are working don t plugor pullout DMX512 data cable with the power on This willdestroy the port electric components of the console Don t splash any liquid to the scanner console This willshatter the inside components of the console and make functions failure Scanner console is precision electric equipment Please pay attention to moistureproof protection and dustproof protection And please clean the control panel in schedule with non chemical cleanser Contents Contents inthe package 512 console 1 User s Manual 1 Power supply line 1 Connect toscanner 512 console has 2 optical isolated DMX512 signalindependent drive device Sothere are 2 DMX512 XLR D3F The connection of the output socket andthe data cable as following Foot No Data cable 1 Screen net 2 Signal 3 Signal In the end o
6. X Y channels for scanners 512 scanner console can control the scanners with 8Bit or 16Bit X Y resolution Before Sunny scanner console uses modulation wheel to control the X Y position of any DMX512 standard scanner the address of every scanner must be set and the set control channel number of each scanner must be written to the console one by one X axis of 16Bit resolution scanner is controlled by two data channels Y axisis controlled by two data channels too So X Y is controlled by 4 data channels X axis coarse channel high 8Bit X axis fine channel low 8Bit y axis coarse channel high 8Bit and Y axis fine channel low 8Bit For 8Bitresolution scanner X Y is controlled by 2 data channels X axis coarse channel and y axis coarse channel The explanations of the display canbe seenin append table 1 Setting operation of X Y From the User s Manual of the scanner whether the scanne is 8Bit X Y or 16Bit X Y andthe attribute of the corresponding channel can be known Press SET X Y key the indicating light is on Itis in setting scanner s X Y state Usescanner keyboard to choose scanner Use modulation wheel to choose edit item Use modulation wheel to choose the value of the corresponding channel range 1 16 no Repeat step 2 4 to set X Y ofthe other scanners Press SET X Y key to quit the edit state For example _ 5 QORA WN Some 16Bit scanner scanner X coa
7. checking operating parameters of multi chases running simultaneously make a chase to be currentchase one by one Then setits chase speed The music trigger ofa chase Press MUSIC key to make MUSIC indicating lighton Itindicates thatthe current chase isin the music in phase trigger state In this state the chase step time andthe gradual change ratio Cross don t work Run Environment Press SELECT key then press 1 15 number key to make the corresponding indicating light on The chase scene and manual operating included inthis environment will reappear Every correspon ding indicating lights are on Example 5 Run Environment 1 1 Press SELECT key 2 Press 1 number key Press SELECT key again and press the number key which light ison The corresponding environment is closed Then the original state will run continually USER MANUAL1 5 17 DMX 512 CONTROLLER SERIES O Addenda Table 1 Explanations to display contents Display contents Explanations X H X axis coarse Channel high 8Bit channel x I X axis fine channel low 8Bit channel Vai Y axis coarse channel high 8Bit channel Y L Y axis fine channel low 8Bit channel No For 8Bit scanner only X Y coarse channel can be used Sothe X Y fine channel must be set to no CH Abbreviation of CHANNEL The chase step with is the last step of the current chas
8. ofthe scanners can notbe saved Scene Edit The appropriate values of channels suchas color intensity pattern X Y and so on of various scan ners can make a needed light art pattern in the space scene Each scene is an aggregate of the set channels of the various scanners 512 console can save 48 scanner scenes The saved scenes can berun atany moment Important tips For the simultaneous running of the multi scenes and multi chases the different values of the same channel which are produced at the same time are treated by HTP Technique So following setting is proposed 1 Forall scenes which just include pattern effect controls such as color pattern and so on the values of X Y intensity and so on are setto 0 2 If chase justinclude the controls like X Y intensity and so on the values of the other channels are set to0 USER MANUAL 0 17 DMX 512 CONTROLLER SERIES o Process of scene edit 1 According to the ways of manual operation choose scanner and set the various channel values and X Y position 2 Press SAVE TO SCENE key then press scene district key and scene number key In the end press ENTER SWITCH key to confirm the save Example If you want to save the current scanner running states to A13 scene press SAVE TOSCENE key then press A key in SCENE and press 13 key in the end press ENTER SWITCH key T
9. DMX 512 CONTROLLER SERIES DMX Controller SUBBY 512 Version 1 0 2010 01 28 User Manual This product manual contains important information about the safe installation and use of this product Please read and follow these instructions carefully and keep this manual ina safe place for future reference DMX 512 CONTROLLER SERIES O Summary 512 consoleis specially designed to control the various scanners To adopt double CPU work in coordination high speed MCU proceed the precise control to achieve 16Bit X Y movement Up to 32 scanners may be connected with a maximum of 16 channels each Multi scenes and multi chase programs can be operated atthe same time and 32 scanners can be selected simultaneously It is equipped with two groups of DMX 512 signals and is adapted for wide range of power voltage The edit mode and running mode of the console are convenient and flexible So itis easy to edit and to ha ndle Sunny 512 is the best suit for art show theater dancing and acting Features DMX512 1990 standard 512 DMX control channels 2 output with opticalisolatedwithstand 2000Vrms Independent slot structure whichis easy to change Up to 32 scanners may be connected witha maximum of 16 channels each Alarge backlight LCD to display operation parameters 16 sliders for channel 1 slider for speed control 1600 chase steps 48 chases upto 100 steps each Each step contains its speed and cross time can be setrespectively
10. Modulation wheel controls Y H only When the X Y channelis controlled by modulation wheel the corresponding X Y slider is locked The X Y position of a scanner must be set by modulation wheel In the manual mode of a scanner slider and modulation wheel can change the value of the correspon ding channel The screen displays the value ofthese channels When the scanner key is pressed the X Y current appears at the right part of the screen Turn the mo dulation wheel the values of X Y can be changed Move 1 8channel slider the screen displays CH1 2 3 4 5 6 7 8 X 120 123 58 204 32 12 0 0 0 Y 891 CH9 10 11 12 13 14 15 16 X 120 Move 9 16 channel slider the screen displays 0 0 14 128 0 0 0 0 Y 891 USER MANUAL 9 17 DMX 512 CONTROLLER SERIES Note the values of channel and X Y depend on the slider position and the X Y modulation wheel value In amoment of slider moving the value display will disappear until the next moving Manual operation of single scanner 1 Press HOLD key to make the indicating light off 2 Choose scanner press scanner number key cooperate with 1 16 land keys the indicat ing lightis on 3 Use CHANNELS sliders to setthe channel values use modulation wheel and to adjust X Y position Manual operation of the same kind multi scanners 1 Press HOLD key to make the indicating light off 2 Choose scanner according to the 2 step of Manual operation of single scanner multi scanners
11. a new chase step after the current one If the current chase step is the last one of the chase the parameters of the current chase step are copied automatically to the new added chase step USER MANUAL 6 17 DMX 512 CONTROLLER SERIES ENTER SWITCH Enter Switch key In scene edit and environment edit it is ENTER key In chase edit itis SWITCH key Modulation wheel In editchase isused tochange edititem is used to set the value ofthe item In manual operation mode is usedto setthe X position of lt O 4 O 4 a scanner is used to set the Y position Y Other MUSIC Music trigger key When the indicating lightis on chase follows the musicrhythm When the indicating lightis off chase follows the settime multiplying the speed percentage set by SPEED slider BLACKOUT Blackout key i When the indicating lightis blink console run an inside black scene automatically When the indicating lightis off console isin the normal state SPEED chase speed slider Push the slider to FAST chase runs faster Push the slider to SLOW chase runs slower chase step Time x SPEED percentage the actual running time of the current chase step The changeable range is 300 30 When SPEED is 100 chase step runs on the set time and the set cross time When the higher speed is needed SPEED should be adjusted to smaller than 100 The fast is 1 3 of the st
12. andard speed when SPEED is 30 When the slower speed is needed SPEED should be adjusted to larger than 100 The slowest is one third of the standard speed when the SPEED is 300 LAMP 5V LED lamp socket The power of the lampis smaller than 0 5W POWER Power switch of the whole equipment LED LAMP POWER Introduction tothe rear ae pp Li z HH ay ey Af my FHH f IF Af Af A 9V 1000MA min Ne SERIAL NO i C Power input DOO GS x Q Q e uo e i DMX512 outpu Audio signalinput USBI EX Fi AB Explanation Thereare 4 optical isolated DMX512 outputsockets which have the same signals Audio signal input socket isa 1 4 mono socktwith C10 10dB inputlevel When the plugis connected music trigger signal comes from audio input signal When the plugis pull out music trigger signal comes from the environment sound picked bythe inside microphone Please use the standard fuse The standard is printed onthe backboard The power supply mustbe connected to the earth line to ensure the safety USER MANUAL 7 17 DMX 512 CONTROLLER SERIES O Set
13. ar allstates chosen by scanner keys and quit manual operation SCANNER 1 16 Section key CLEAR O o 7 When the indicating lightis on 1 16 scanner can be chosen from number keyboard 17 32 Section key When the indicating lightis on 17 32 scanner can be chosen from number keyboard OF OF ora OLA HOLD Scanner hold key When the indicating lightis on it isa scanner hold state Multi scanner can be manual operated 1 116 Scanner number key Press these keys the corresponding indicating lights are on and indicate the scanners are in manual operating states USER MANUAL 4 17 DMX 512 CONTROLLER SERIES Press again there are two states HOLD lightis offthe scanner can t be operated manually HOLD lightis onthe scanner isin ahold state CHANNELS In manual state 16 channel d a o slides can set the channel le value of the chosen scanner CHANNELS must cooperate with SCANNER lo o O e0000 ee o o nxn a
14. can be chosen Note only the scanners with the same X Y channelcan be chosen atthe same time 3 Use CHANNELS sliders to set the channel values Use modulation wheel to adjust X position Use modulation wheel to adjust Y position And the adjusted channel values are set to all chosen scanners atthe sametime Manual operation of the different kind of multiscanners For the manual operation of the different kind of scanners set one kind of the scanners and make these scanners inthe hold state first Then choose another kind of the scanners to set Thisis also the usual operation method to set1 scene The hold state of the scanner can be change tothe choosing state by pressing its key to make the indicating light on 1 Press HOLD key to make the indicating lighton 2 Choose scanner use the way of choosing single scanner or multi scanners to choose scanners Note only the scanners with the same X Y channel can be chosen at the same time 3 Use CHANNELS sliders to set the channel values Use modulation wheel and to adjust X Y position 4 Press the corresponding number key of the chosen scanner to make the indicating light blink The set values ofthese scanners are inthe hold state And the adjusted channel values are set to all chosen scanners atthe sametime 5 Repeat 2 4 steps to set other scanners manually Cancel the manual operation of scanner Press CLEAR key the manual operation is canceled and the set values
15. current tothe nextstep Theunit is0 1s The change able range of Time is 1 600 It means thatthe minimum time ofa stepis 0 1s and the maximum is 60s Cross value The value defines the time ratio of the gradual change treatment between two chase steps The range of the value is 0 100 Forinstance inthe currentstep Time 10 Cross 60 express thatthe current step willuse 1 second and use 40 of this 1 second as stay time 60 as gradual change treatment time for moving tothe nextstep USER MANUAL11 17 DMX 512 CONTROLLER SERIES O Process ofchase edit PROGRAM CHASE 1 Press EDIT CHASE key Please selecta chase 2 Choose the chase number which will be edited Forinstance ifwant to edit chase PROGRAM CHASE CHASE C15 Stepis empty C15 press C keyin CHASE then press 15 key ifthe chaseis empty the screen will display 3 Press ADD key toadd a step Current step Pehase Total Step Step Time Crossh gt C15 1 x 1 5 0 Current edit Current edit step Default 0 number islast step Default 5 Unit 0 1s 4 Use modulation wheel to change the items such as STEP TIME and CROSS Use modulation wheel to set the value of the current item 5 Setthe channel values of various scanners in the current step manually Use key to change the setting state of chase step the various channel values of manual operating scanners and the setting state of X Y 6 Repeatstep 3 5 to
16. e Use JENTER SWITCH key can switch the display contents The parameter in the is the current adjustable item Its value can be change by modulation wheel PROGRAN CHASE Chase edit state The chase with this number is empty the chase CHASE xxx Step Is empty number is replaced by xxx MEMORY IS OVERFLOW There isno spacein memory USER MANUAL1 6 1 7 DMX 512 CONTROLLER SERIES O Technical specification Digital control mode DMX512 1990 DMX control channelamount D12 Control scanner amount s Control channel distribution of a scanner 16 control resolution ofa scanner l6bit optical isolated independent digital output drive module 4 Electrical isolation of optical isolated independent digital output drive module Z000VDC LCD backlight screen 40 character x2 row BLACKOUT function V Manual operation function V Simultaneous manual operation ability 3a Scanner scene 48 Scene amount ofsimultaneous running scanners 48 Scanner chase 48 Maximum chase stepsin a chase 100 Chase step time 0 1s 60s Chase gradual changeratio Cross 0 100 Totalcapability of chase steps 1600 Chase amount ofsimultaneous running scanners 8 Music in phase chase 10 10dB audio line input inbuiltmicrophone Channel sliders 16 Speed slider 1 The ratio range of chase speed 30 300 MODULATION WHEEL 2 Environmen
17. editnext chase step 7 Press EDIT CHASE key to end edit Tips When key is pressed to adda chase step the values suchas the channel values of all scanners the values of TIME and CROSS are copied to the new added chase step automatically So just change some items to make a new chase step If the current chase is empty all channel values are setto 0 In the edit state use key to switch between the chase setting state and manual setting state which set the various channel values and X Y values of scanner In different state the control object of the modulation wheelis different In chase setting state use modulation wheel to change the current step This can check the space pattern effect of every chase step and can change the channel values of some scanners in the current chase step immediately Press DELETE key to cancel the current chase step USER MANUA 2 1 7 DMX 512 CONTROLLER SERIES ie Environment Edit The current manual operating state scene operating state and chase operating state are the operating environment If the current environment is saved itis very convenient to reuse this environment Acomplex environment like an environment some chases some scenes some manual operation can be saved asan environment It canbe saved to cover the original environment number or saved as another environment number 512 console can save 15 environment The environmentcan be chosen by keyboard directly To avoid mistake
18. f DMX512 data cable a120 matching resister must be connected to the end ofthe cable toimprove the signal transmission quality USER MANUAL 2 17 DMX 512 CONTROLLER SERIES The set of the scanner address 512 console distributes the DMX512 address of various scanners with the fixed space of 16 channels Thereference is as following oe a f SION Os m eon gt w eo Y USER MANUAL 3 17 DMX 512 CONTROLLER SERIES Introduction of the panel The panelis as following To _ eS SODMX 512 Intelligent Lighting Controller EE SCANNER CLEAR 1 16 17 32 HOLD O O O Sunny 512 Controller LED LAMP Cc I ANNE m n SPEED o N wo a o Tr Oe olynlalolols rT Ow TOO 70000808 A Oc gt O c e 0000000 C Z O gt OR ec e00 0000 o O a a Om c e 0e 00000 e e000 000 a rT Oa 7028 0000 I On 020800 A O o n gt Co Os olny laeloleols Ce D Oo olny la gt
19. he current district 3 Press 4 key to run chase A04 4 Press 13 key to run chase A13 5 Press B key to choose B asthe current district USER MANUAL1 4 17 DMX 512 CONTROLLER SERIES a_i 6 Press 7 key to run chase BO 7 Press C key to chooseC asthe current district 8 Press 10 key to run chase C10 Now the above 4 chases are running simultaneously Tips i If the chosen chaseis empty without a CHASE Stepis empty chase step the screen will display Check the various operating parameters of multi chases running simu Itaneously When multi chases are running the last parameters are displayed in the screen Inexample4 the parameters oflast chase C10 are displayed inthe screen If the parameters of some chases are wantto be change the chase mustbe setas current chase and the chase is display in the screen Forinstance inexample 4 here the parameters of last chase c10 are displayed in the screen Ifthe parameters of BO7 are wanted to be seen just press B 7 press B key and hold then press 7 key This method does not affect the current chase running Adjust chase speed The operating speed ofthe current chase can be change by moving SPEED slider Chase step time value x speed ratio real running time ofthe current chase step Using the method of
20. ight on Adistrict isin the single scene running mode 4 Press 1 key to run scene A01 Example 2 Run A02 A10 B15 C07 scenes at the same time Press A key to choose Aas the current district Press SINGLE key to make SINGLE indicating light off It isin the multi scene running mode Press 2 key to run scene A02 Press 10 key to run scene A10 Press B key 15 key to run scene B15 Press C key 7 key torun scene CO7 Now the above scenes are running simultaneously Oooh WN Tips In the step 3 of example 2 if press SINGLE key to make SINGLE indicating lighton perform step 4 torun scene A10 and scene A02 will close automatically Running chase Running chase the screen will display CHASE TRIGGERSTEP SPEED A08 AUTO 1 100 Chase number Current chase step Trigger mode Speed ratio Example 3 Running chase A08 1 Pressi SINGLE key of CHASE to make SINGLE indicating light on it isin the single chase running mode 2 Press A key to choose Aas the current district 3 Press 8 key to run chase AO8 Example 4 Run A04 A13 B07 C10 chases at the same time 1 Press SINGLE key of CHASE to make SINGLE indicating light off It isin the multi chase running mode 2 Press A key to choose Aas t
21. ips Scene editcan be done atany time After the various setting to multi scanners if the art pattern is what you want just perform the above step 2 The running states of all scanners can be saved toa scene number For instance using simultaneously running scene B02 and CO7 as basic choose 3 scanners manually and set the light beam to some position then save the combination to scene C01 So run C01 can recur this light art pattern combination Copy of Scene Example Copy scene A01 to scene C10 1 Press A key in SCENE then press 1 key Then the console run A01 scene 2 Press SAVE TO SCENE key press C key in SCENE then press 10 key and ENTER SWITCH key Chase Edit 512 console can save 48 chases Achase isa buildup of some chase steps The conceptof chase step is very similar to the scene Achase step is made up of the aggregation of each channel value of various scanners the step time and the graduate change parameter Cross The total capability of the chase step is 1600 Each chase can have upto 100 step In each stepofa chase the step time and the gradual change parameter Crosscan beset independently The standard operating speed of achase is decided by the step time and the gradual change parameter Cross ofa step The speed canbe adjusted from 1 3 to 3 times as the standard speed by SPEED slider Step time value The value defines the interval time between the
22. made by touching keyboard by accident itis needed to press SELECT key first and then press the environment number key to choose the environment Edit process 1 Base on the need to choose the following operating mode a Scanner manual operation b Scene operation multi scenes running simultaneously c Chase operation up to 4 chase running simultaneously 2 After pressing SAVE TO ENV key a Ifno environment program in current environment the screen displays as left figure b Ifthe currentincludes the environment program the number of the environment is displayed If ENTER SWITCH key is pressed the current environment will coverthe contents of the Original environment If itis needed to save to another number then 3 Press SELECT key 4 Press 1 15 key y Save the Current Environment to ll 5 Press ENTER SWITCH keyto conform Ok gt Save the Current Environment to Ok gt Tips To save the environment it is not needed to press SELECT keyfirst To run environment itis needed to press SELECT key first and then press number key USER MANUAL 3 17 DMX 512 CONTROLLER SERIES o Running Running scene Example 1 Single running scene A01 1 Close running scene B andC one by one 2 Press A key to choose Aas the current district 3 Press SINGLE key to make SINGLE indicating l
23. nel of various scanners are different With the particular comprehension to the control contents of each channel of various scanners the scanner connected to the control net can be controlled with facility The control contents of each channel of ordinary scanners can be seen inthe append tables In the edit state or running state itcan be operated manually Manual operation is the highest priority operation The chosen scanner will be divorced from the runn ing scene chase and environment automatically Manual operation is the basic operation Manual op eration especially multi scanner manual operation can be saved as scene whichis the basic operati on of edit chase step Cooperated with 1 16 Jand keys i keys can make choice to 32 scanners When the number indicating light is on that scanner isin the chosen state It can be setby CHANNELS slider and modulation wheel CHANNELS 1 16 channel sliderand modulation wheel The values of each channel of scanners can be setby 1 16 channel sliders X channel of a scanner is set by modulation wheel Y channel is set by modulation wheel The set range of a slider is 0 255 Whether 8bitor 16Bit X Y scanner the set range of a modulation wheelis 0 999 It represents the mov ing range of X axis or Y axis For 16Bit scanner modulation wheel gt controls X H and X Lat the same time Modulation wheel controls Y H and Y L atthe same time For 8Bit scanner modulation wheel controls X H only
24. o n gt gt M e o n gt gt ol n aloloelse o In E T gt O E C C E C wo Sunny 5 4 2 SAVETO EDIT SAVETO SELECT SCENE CHASE ENV O O O O O O O DELETE ADD OOM 0O O00 00 OO SET X Y ENTER SWITCH O 00 OW OW O 00 O O OO 00 00 O SCENE CHASE ENVIRONMENT aI 2 DMX OPERATOP XE SCANNER CLEAR Clear key Cle
25. rse channel 5 X fine chan 6 X 5 Y 7 Y coarse channel 7 Y fine channel 8 ev soo we so me X o X The setting of 16Bit scanner e pes yo aS SET XY CHANNEL X H Scanner 1 5 j f Scanner s number Setting the corresponding channel number is currentitem The setting of 8Bit scanner SET XY CHANNEL X H Scanner 1 5 Scanner s number Setting the corresponding channel number is currentitem USER MANUAL 8 17 DMX 512 CONTROLLER SERIES i For 16Bit scanner if the values of X H Y H are set and the values of X L Y Lare set to no the 16Bit scanner will be running in 8Bit X Y resolution This will lost some characteristics of 16Bit scanner such as high precision of X Y orientation and the smoothness of the moving trace Auto correction to the wrong setting X L no Y L no must be set at the same time That just one is no is a mistake 512 console checks and corrects X L Y L to be no at the same time automatically Check the X Y setting of the scanners Use following ways to check 1 Press BET XY key the indicating light is on It is in setting scanner s X Y state 2 Use scanner keyboard to choose scanner Check the X Y setting 3 Repeat step 2 to check X Y setting of all scanners 4 Press SET XY key to quit the edit state The manual mode The scanner s channelvalues such as intensity gobo X Y pattern and color can be set manually Usually the control contents of each chan
26. t Ld Copy of scannerscene V All scanner X Y channels can be controlled by modulation wheel V Data auto save VA DMX signal outputconnector XLR D3F x 4 Audio signal inputconnector 1 40 mono socket Power supply range AC 100V 240V 50 60Hz 9V1000mA Consume power OW Work temperature range 0 40 C Work environment Waterproof dustproof Size 483mm x 400mm x 105mm Weight 8kg USER MANUAL 17 17