Home
Cavex Alginate Mixer II
Contents
1. properly Watch out for damage to the cup or lid P Drive defective Send the appliance for repair see list of distributors NB Do not forget to put back the two locking screws before transporting the appliance for repair see fig 1 Specifications 3400 rpm 60Hz 2900 rom 50Hz
2. Cavex Alginate Mixer II Automatic mixer for Alginate impression material User manual Installation Operation Troubleshooting Contents Page 2 General information for the user Page 3 Description of the Alginate Mixer vvith accessories Page 4 Installation Page 5 Operation Page 8 Setting the optimum mixing time Page 8 Maintenance Page 9 Troubleshooting Page 11 Specifications General information for the user Congratulations on the purchase of your Cavex Alginate Mixer ll an automatic mixer for alginate impression material Please read this user manual carefully before using the Alginate Mixer Il Its proper use will improve the quality of the mixed alginate impression material and also increase the mixer s working life You should therefore keep the user manual in a safe place and ensure that employees who will be using the Alginate Mixer ll receive proper training Important Cavex Holland BV cannot accept responsibility for any inadequate performance damage or accidents resulting from a failure to connect the Alginate Mixer ll in the manner specified below using the Alginate Mixer ll for materials other than alginate impression material or in a manner other than that described below using parts other than those supplied for the intended purpose by Cavex or repairs or modifications other than those made by experts appointed by Cavex for that purpose Description of the Alginate Mixer Il with access
3. commended volume Excess water may reduce the mixing performance of the Alginate Mixer II and lead to lumps in the alginate impression material Fig 3 Close Close the mixing cup vvith the lid Press to close tightly fig 7 4 Mix Place the filled and closed mixing cup in the holder fig 8 Close the cover of the Alginate Mixer Il properly otherwise the mixer will not Start and press the start stop button Start Stop as shown in fig 9 The mixer starts and the displayed mixing time will count down until the end of the mixing time when the mixer will stop automatically N B 1 You can stop the Alginate Mixer II at any time by pressing Start Stop N B 2 Only open the cover when the mixer has come to a halt 5 The result Open the cover when the mixer has completely stopped and remove the mixing cup from the holder You can easily remove the mixed alginate impression material from the mixing cup using the spatula fig 10 Setting the optimum mixing time Set the optimum mixing time as follows Use the memory button Memo Mode to select the required memory location Set the required mixing time in sec with the Up or Down button Now press the Up and Down buttons simultaneously you will hear 2 high pitched sounds and the display will flash twice The selected mixing time has been saved to memory Different mixing proportions Using 30 less water than recommended produces a stiff algi
4. emory location Mixing time sec You can easily change the mixing times to Suit your own requirements and store them in memory See Setting the optimum mixing time on page N B 2 The recommended mixing times for CA37 Normal Set and Cavex Impressional Normal Set are between 8 and 12 seconds for 1 2 and 3 small spoonfuls of powder Extending the Alginate Mixer II mixing time will reduce the hardening time by a few seconds N B 3 In general alginate impression material mixed in the Alginate Mixer II will harden sooner than you are used to when mixing by hand This is because the Alginate Mixer Il mixes more thoroughly Using the normal setting for alginates is therefore recommended 2 Putthe required amount of powder to the mixing cup fig 5 and add the required volume of water according to the manufacturer s instructions For optimum mixing mix slightly beforehand using the stirrer provided fig 6 The total contents of the mixing cup powder water must not exceed 100 g lt is important to close the lid properly to prevent alginate impression material from leaking out during mixing This could adversely affect the operation of the Alginate Mixer Il Replace the lid and or mixing cup when it can no longer be closed properly owing to wear If required the preparation proportions for the Cavex alginate can be adjusted To this end the volume of water can be reduced by no more than 30 below the re
5. nate This is the ideal consistency for making the functional impression initial impression for making a suitable individual mould for a stable prosthesis Maintenance 1 Mixing cup Thoroughly clean the mixing cup and lid after mixing Hardened alginate impression material can be easily removed Do not use a sharp object like a knife as this will scratch the surface Ensure that the hole in the lid of the mixing cup does not become blocked fig 11 as that would make it extremely difficult to open and close the lid Mixer Clean with a damp cloth possibly using a neutral cleaning agent Never use solvents i Press the top lid down tightly to the mixing cup Id Rotate the cup lid to the end for lock Troubleshooting What to do Appliance will not switch on Power lead is not connected Check the power lead connection to the appliance and power point Fuse has blown Check for external causes and correct them Then replace the fuse If the fuse blows again send the appliance for repair a does not light Printed circuit board defective Send the appliance for repair FP Motor or drive defective Send the appliance for repair amanit of rotation too low Motor or drive defective Send the appliance for opal while rotating must not exceed 100 g Mixing cup is empty Never switch on the Alginate empty Leakage of powder and or water Always close the lid of the during mixing mixing cup
6. ories 1 Mains switch 1 0 2 Power button Power 3 Memory button Memo Mode 4 Start stop button Start Stop 5 Display 6 Buttons for setting the mixing time 7 Memory indicator Up Down 8 Power lead 9 Power lead connector 10 Fuse holder 11 Mixing cup 12 Mixer case Spatula Stirrer Dose measuring jug Plastic container with magnet 0 1 2 13 4 5 6 1 1 1 Installation 1 Remove the two locking screws underneath the Alginate Mixer II fig 1 Keep the locking screws in a safe place If the Alginate Mixer ll is transported e g if sent for repair they will have to be screwed in again to prevent further damage 2 Place the Alginate Mixer ll on a solid surface that is stable and flat Ambient temperature 2 C 40 C 35 6 F 104 F 3 Check that the voltage indicated on the device is the same as your mains supply voltage and connect the Alginate Mixer II to an earthed power point using the power lead provided fig 2 Operation 1 Switch on the Alginate Mixer Il Switch on the power using the mains switch I O fig 3 on the back of the device and then press the power button Power fig 4 on the control panel The entered mixing time in seconds will be indicated on the display Choose the required mixing time using the memory button Memo Mode N B 1 The following mixing times have been preprogrammed at the factory M