Home
MW-3E mix/wipe user manual
Contents
1. Menu Num Heading Automation Function 20 MATTE none Points to adjacent menu for COLOUR information only 21 L ee Press this button and the three H Menu Level B digipots indicated by the lit LED s will S 0 235 H u change the Luma Hue and Saturation enu Level C 0 255 S of the Matte colour 22 Hold To Black This is the Intermediate source for the U and V Fades 23 BACK none Go To the Top Level Menus Menus 24 27 Audio Set up Menus MW 3E only NEXT for more Menu Num Heading Automation Function 24 Audio In 999 gt Changing this value will cause the Lead Lag 999 fields next IN audio to either Lead or Lag the Video Transition by the set number of fields 25 Audio 999 gt Changing this value will cause the Out 999 fields next OUT audio to either Lead or Lead Lag Lag the Video Transition by the set number of fields 26 Fade 0 gt 250 Press this button and the
2. SDI A B mixer with embedded audio processing user manual Table of Contents FT SYVSICI QV GIVICW ssrireisi eneee E caeeel incite search ech eens eerie 4 1 1 The MW SE product ccccccecccssceceeeceseeceseeceueecaueesaueeseuessausesueessees 4 1 2 Applications for the MW SE ccccccsccsseccsseesseeseeeeeeesseeseseeneeeseeesees 5 t3 Associated EquPmMEN eese ee ey ee 5 1 3 1 Chassis Types ccccccceeeccesecceeeesseeeceececeueecsueeseueecueecaeeeseeeesseesseesenees 5 T2 COMO UNICO a E 6 MNS TAN OM ere E E E E E E eee 7 2 1 Installation of the MW 3E Product cccccecccceececeeeeceeeeseeeeseeeeseeeesaaees 7 2 2 Installing the MW S3E into a flexXiBOX cc ecceeccseeeceeeeeeeeceeeeeeeeneeeseeeeees 7 2 3 Connecting Video to an MW SE ccccecccccseeeeseseeeseeeeeseeeesseeeesaaeeeeas 8 2 4 Connecting Panels to the MW SE c cc ccccccsceeeceeeeeseeeeeaeeeesaeeeesaeeeeeas 8 OD ON ANON xsseeccsecaeecececeeaceascecasecosananecasarssscexcescere eveccssersasuereesatceaerecesaxecececocesate 10 31 Manu ualcontorol the MIVV 9E vicsisssisisscsvadewstvwadseasvescnta saat iaeudseidavadaaedavedsieed 10 3 1 1 Naming The Sources to the MW SE ccccceceeseeeeeeeseeeeeeesaeeeeeas 10 3 2 Automation Control of the MW SE cc ceccceeeeeseeeeeeeeeesseeeeeseeeesaaeees 11 3 3 Operational Menus for the MW SE ccccccseeeesseeeeeeeeeeeeeeeeseeeesaaeees 11 4 Te
3. cccccseeeeeseeeesseeeeseeeeeseeeeeees 21 Figure 4 2 Diagram of GPI Output GPI1 4 0 oe cecceceeeeseeeeseeeeseeeeseeeeseees 22 a eyeheight Unit 34 Park House Watford Business Park Greenhill Crescent Watford Herts GB WD18 8PH Reg No 2855535 Telephone 44 0 1923 256 000 Fax 44 0 1923 256 100 email eesales eyeheight com System Overview This manual describes the function of the MW S3E which is the most full featured Eyeheight mixer wipe unit Eyeheight also offer the MW 2 and MW 3 range of GeNETics modular products The MW 3 product The MW SE is an A B 2 Input SDI Mixer WipeCut unit which will output a variety of transitions commonly used in transmission and post production The main features are as follows A B Mix Cut transitions A B Wipe transitions with 8 wipe patterns with coloured soft borders Embedded Audio Mixing follows video transitions Embedded Audio Lead Lag Transitions Embedded audio manipulation LR swap Mono Programmable Auto or manual video and audio transitions Preview Output with safe area generator built in Internal Matte and Black Generator Up to 32uS user definable synchronisation window for A B Inputs External Digital Reference Input ensures output stability Transparent to all embedded signals Automation controllable 6 user memories GPI inputs to enable take to A or take to B plus 6 Scripted GPI s Relay outputs to indicate on air source either A B Matte or Black
4. Figure 1 1 MW 3E module 4 eyeheight Unit 34 Park House Watford Business Park Greenhill Crescent Watford Herts GB WD18 8PH Reg No 2855535 Telephone 44 0 1923 256 000 Fax 44 0 1923 256 100 email eesales eyeheight com Le Applications for the MW 3 Applications for the MW 3E include the following e Presentation and Master Control systems Inc Eyeheight PresTX e Simple Video and Audio Mixing systems Post Production e Offline duplication suites top and tailing The MW 3E will be used in a situation where any A B mix or wipe transitions are used Normally the A and B inputs will be fed from a routing switcher to obtain the maximum functionality MW3 P Ref _ A PGM gt gt B PVW Routing l switcher gt Multiple Inputs Multiple Outputs Figure 1 2 MW 3E configured witha router to provide expanded inputs 3 Associated Equipment The MW SE is a module and requires both a chassis and a control surface to function 1 3 1 Chassis Types e The 1RU chassis is called a flexiBox Order code FB 9 This will hold a maximum of 3 MW 3E Modules with Hot Swap redundant PSU option and Hot Swap Modules e The 1RU chassis is called a maxiBox Order code MX 9 This also will hold a maximum of 3 MW 3E Modules but has no redundant PSU option and the MW 3E units must be factory fitted ee eyeheight Uni
5. 3E Module Ref REF VIR 2 op m B Input PST Output Mon V A i SPG Figure 2 1 Typical connections for an MW 3E Module In the above diagram the SPG provides a reference such that VTR1 and VTR2 give synchronous output video The A and B input must be within 32uS for the MW 3E to operate correctly The MW 3E Module has a number of user configurable jumpers which can change the function of the 5 SDI BNC Connectors These are shown along with their default configuration below These jumpers are found close to the BNC Connectors MW 3 3E Processor Lower Card MW 2 Processor Upper Card kerin Fam Pgm Pst Pst B In Aln Pgm Serial VO Serial I O Please refer to table for pinout details Figure 2 2 User configuration of the 7 SDI BNC Connections 2 4 Connecting Panels to the MW 3 The MW SE may be operated using a FP 9 Flexipanel locally mounted For a more operational environment the MW 3E may be supplied with a desk mounting FP 10 unit and also possible a VP 10 Desk mounting Video T Bar manual transition unit For detailed information on connecting remote panels refer to the 3 eyeheight Unit 34 Park House Watford Business Park Greenhill Crescent Watford Herts GB WD18 8PH Reg No 2855535 Telephone 44 0 1923 256 000 Fax 44 0 1923 256 100 email eesales eyeheight com section Connection of Remote Panels to a flexiBox in the geNETics Hardware Installation Guide Below
6. two digipots j4 eyeheight Unit 34 Park House Watford Business Park Greenhill Crescent Watford Herts GB WD18 8PH Reg No 2855535 Telephone 44 0 1923 256 000 Fax 44 0 1923 256 100 email eesales eyeheight com Rate fields 27 BACK none indicated by the lit LED s will change the In and Out Fade rate for the Incoming and Outgoing Audio Go To the Top Level Menus Menus 28 31 AUDIO Set up Menus MW 3E only NEXT PREV to navigate Automation O Follow 1 Seperate Menu Num Heading 28 AUDIO O 12dB 1 6dB 2 0dB 3 6dB 4 12dB 5 18dB O Stereo 1 L lt gt R 29 CHANEL GAIN 30 ABmode 31 BACK none Function lf this is set to Follow the embedded audio mixing will follow the video mixing If this is set to Separate the embedded audio is controlled by the transitions in next 4 menus only separate mode is used by Automation systems only to achieve split video audio transitions This sets the overall gain on the Embedded Audio This applies only for the MW 3E Module which incorporates embedded audio mixing Press this button and the two digipots indicated by the respective LED s will Cause modification to the A and B embedded audio as follows Stereo No change Left and Right Swapped Left to both Left and Right Right to both Left and Right Mono Go To the Top Level Menus Menus 32 35 AUDIO Set up Menus MW 3E Automation only PREV for less 15 eyehei
7. ACK none Go To the Top Level Menus Menus 16 19 VIDEO Transition Set up Menus NEXT PREV to navigate Menu Num O 17 Heading Automation Function BORDER NONE Points to adjacent menu for COLOUR information only Pe ae A Press this button and the three H Menu Level B Gigipots indicated by the lit LED s will S 0 235 H u Change the Luma Hue and Saturation enu Level C 0 255 S of the border colour 3 eyeheight Unit 34 Park House Watford Business Park Greenhill Crescent Watford Herts GB WD18 8PH Reg No 2855535 Telephone 44 0 1923 256 000 Fax 44 0 1923 256 100 email eesales eyeheight com 19 MANUAL TRAN 0 799 This will manually move the Transition point between PGM and PST 0 100 BACK none Go To the Top Level Menus Menus 20 23 VIDEO Transition Set up Menus PREV for less
8. Business Park Greenhill Crescent Watford Herts GB WD18 8PH Reg No 2855535 Telephone 44 0 1923 256 000 Fax 44 0 1923 256 100 email eesales eyeheight com Menu Level B modification to the Pixel 0 624 Timing 37nS per step and Line Timing 64uS per step 48 m 0 EDH Off Re insert EDH Control 1 EDH On Off On 46 Software none Shows the software version 47 BACK none Go To the Top Level Menus Menus 48 51 Utility Menus Memories NEXT for more Menu Num Heading Automation Function 48 MEM1 1 Recall Pressing this will recall Memory number 1 User Names can be programmed in to the memories using a keyboard See geNETics User guide section Giving product Memories names 49 MEM2 1 Recall Pressing this will recall Memory number 2 50 MEM3 1 Recall Pressing this will recall Memory number 3 51 BACK none Go To the Top Level Menus Menus 52 55 Utility Menus Memories NEXT PREV to navigate Menu Num Heading Automation Function 52 MEM4 1 Recall Pressing this will recall Memory number 4 53 MEM5 1 Recall Pressing this will recall Memory number 5 I8 eyeheight Unit 34 Park House Watford Business Park Greenhill Crescent Watford Herts GB WD18 8PH Reg No 2855535 Telephone 44 0 1923 256 000 Fax 44 0 1923 256 100 email eesales eyeheight com 54 MEM6 1 Recall Pressing this will recall Memory number 6 55 BACK none Go To the Top Level M
9. DAD al Pl eyeheight Unit 34 Park House Watford Business Park Greenhill Crescent Watford Herts GB WD18 8PH Reg No 2855535 Telephone 44 0 1923 256 000 Fax 44 0 1923 256 100 email eesales eyeheight com 4 3 CHP IOO SDI TC GPI Card 4 3 1 Jumper Links on the Timecode and GPI 1 0 card Set to the Right SDI Jitter Filtering selection Set to Top Polarity selection for GPI Relay Output 1 Set to Top Polarity selection for GPI Relay Output 2 Set to Top Polarity selection for GPI Relay Output 3 Set to Top Polarity selection for GPI Relay Output 4 Jumpers LK1 gt 4 set the polarity of the relay Pin 1 3 5 7 Pin 2 4 6 8 Figure 4 2 Diagram of GPI Output GPI1 4 4 3 2 Rear 25W D Type Pinout General Purpose Output 1a GPO1a Isolated Relay closure Tally Out A On Air General Purpose Output 1b GPO1b Isolated Relay closure Tally Out A On Air General Purpose Output 2a GPO2a Isolated Relay closure Tally Out B On Air General Purpose Output 2b GPO2b Isolated Relay closure Tally Out B On Air General Purpose Output 3a GPO3a Isolated Relay closure Tally Out Matte On Air General Purpose Output 3b GPO3b Isolated Relay closure Tally Out Matte On Air General Purpose Output 4a GPO4a Isolated Relay closure Tally Out Black On Air General Purpose Output 4b GPO4b Isolated Relay closure Tally Out Black On Air General Purpose Output 5 GPO5 Open Collec
10. chnical ADD Ndiix ccccccccseececccseeceeeceucecseeseeeeeaeecaeecaueeceeseeeseusenseenseesags 21 4 1 Technical Specification for the MW 3E ccccccsececseeeeeeeeeseeeeeeeaeees 21 4 2 Jumpering the l BUS CAN BUS Termination sssoeeeeeeeneneenneennn 21 4 3 CHP 100 SDI TC GPI Cardo eccccccseeceeceeeeeeseeeeeeseeeeeesaeeeeeaas 22 4 3 1 Jumper Links on the Timecode and GPI I O Card ccceceeeee eee 22 4 3 2 Rear 29W WI Ve PFNOU senere ea E EE 22 ie eyeheight Unit 34 Park House Watford Business Park Greenhill Crescent Watford Herts GB WD18 8PH Reg No 2855535 Telephone 44 0 1923 256 000 Fax 44 0 1923 256 100 email eesales eyeheight com Table of Figures ICIS TT WV MOE e E 4 Figure 1 2 MW SE configured witha router to provide expanded inputs 5 Figure 1 3 flexiBox with flexiPanel fitted cccccccceeecsseeeseeceeeseeeeeeeeseeesaeeeeeeenes 6 Figure 1 4 FP 10 desktop modular Panel ccccccccseseeeeeeeeseeseeeeaeeesaeeesaeeeesaaes 6 Figure 1 5 VP 10 desktop modular T Bal cccccccccsseeeeseeeeeeeeeeeseeesaeeeesseeeesaaes 6 Figure 2 1 Typical connections for an MW S3E Module cccceceseeeeeeeeeeeeeeeees 8 Figure 2 2 User configuration of the 7 SDI BNC Connections ccceeeeeeees 8 Figure 2 3 l Bus Connections and Termination cccccccccceecceeeseeeeeseeeeesseeeees 9 Figure 4 1 Location Of I Bus Termination LINK
11. cted ee eyeheight Unit 34 Park House Watford Business Park Greenhill Crescent Watford Herts GB WD18 8PH Reg No 2855535 Telephone 44 0 1923 256 000 Fax 44 0 1923 256 100 email eesales eyeheight com 41 None Menu Level A O S Action 1 S Capt 2 DigEdge 3 An Edge Menu Level B 0 4 3 1 16 9 2 16p4 3 3 16p149 4 43p16 9 Menu Level C O Thin 1 Thick 2 Shade 3 Black 42 43 BACK none area When this button is pressed to Green The Three line display in the window indicates the three options which can be changed by adjusting the three rotary digipots A B and C Digipot A Determines the basic Function Selects Safe Action option Selects Safe Caption option Selects Digital Edge option Selects the An Edge option Digipot B Determines the Screen Format Standard 4 3 Screen Standard 16 9 Screen 16 9 Shoot to protect 4 3 16 9 Shoot to protect 14 9 4 3 Shoot to protect 16 9 Not available in 525 Digipot C Determines the Style of Indicate Thin White lines are used Thick White lines are used Shade is used for danger area Black is used for danger area Go To the Top Level Menus Menus 44 47 Utility Menus Timing EDH and S W version Function Menu Heading Automation Num 44 Timing Menu Level A 0 1439 Press this button and the two digipots indicated by the respective LED s will cause 7 eyeheight Unit 34 Park House Watford
12. d Black The procedure is as follows e Plug ina PS 2 Keyboard into the flexiPanel that has control of the MW 3 e Ensure that the correct MW 3 is selected on the device buttons e Press F9 on the PS 2 Keyboard and the word TEXT should appear in the 4 LCD Displays e Type the following Example 1MainTX e Hit the RETURN key This will cause the A side of the mixer to be renamed MainTX To do the B side of the mixer use the Prefix 2 e g 2Bypass To do the Matte use the 3 prefix and for black use the 4 prefix 10 eyeheight Unit 34 Park House Watford Business Park Greenhill Crescent Watford Herts GB WD18 8PH Reg No 2855535 Telephone 44 0 1923 256 000 Fax 44 0 1923 256 100 email eesales eyeheight com 3 2 Automation Control of the MW 3E Automation of the geNETics products is achieved via an RS422 port This port is marked RS422 on the rear of a flexiBox For the port to work a flexiPanel MUST be connected locally on the front of the flexiBox Automation control of the MW SE can be done using two protocol methods e geNETics Automation Protocol e PresTX Automation Protocol Genetics protocol is described in detail in the GeNETics User Guide section titted Automation Protocol on the geNETics Platform The menu list in section 3 of this chapter contains the data information for the protocol PresTX Automation Protocol is used only for the PresTX Presenta
13. d The Hold time is the time that the U and V fades stay on Black Or Matte 10 WIPE 0 Vertical This shows a representation of the P eyeheight Unit 34 Park House Watford Business Park Greenhill Crescent Watford Herts GB WD18 8PH Reg No 2855535 Telephone 44 0 1923 256 000 Fax 44 0 1923 256 100 email eesales eyeheight com Pattern 1 Horiz 2 Vert Curtain 3 Horiz Curtain 4 Diagonal 5 Diamond 6 Arrow Left 7 Arrow Up shape of the currently selected Wipe Transition 11 BACK none Go To the Top Level Menus Menus 12 15 VIDEO Transition Set up Menus NEXT PREV to navigate Menu Num Num Heading Automation Function BORDER a This selects the Type of Border on the 2 Colour Wipe edge between No Border Soft abate Coloured and Soft and coloured 13 BORDER 149 This sets up the Wipe Border Size SIZE between 1 min and 49 max COLOUR 0511 This represents the amount of colour DEPTH in the border when the Soft and coloured border option is selected 0 100 15 B
14. enus Menus 56 59 Utility Menus Memories NEXT PREV to navigate Menu Num Heading Automation Function 56 SAVE 1 Save Pressing this will Save Memory MEM1 number 1 57 SAVE 1 Save Pressing this will Save Memory MEM2 number 2 58 SAVE 1 Save Pressing this will Save Memory MEM3 number 3 59 BACK none Go To the Top Level Menus Menus 60 63 Utility Menus Memories NEXT PREV to navigate Menu Num Heading Automation Function 60 SAVE 1 Save Pressing this will Save Memory MEM4 number 4 61 SAVE 1 Save Pressing this will Save Memory MEM5 number 5 62 SAVE 1 Save Pressing this will Save Memory MEM6 number 6 63 BACK none Go To the Top Level Menus 19 eyeheight Unit 34 Park House Watford Business Park Greenhill Crescent Watford Herts GB WD18 8PH Reg No 2855535 Telephone 44 0 1923 256 000 Fax 44 0 1923 256 100 email eesales eyeheight com Menus 64 67 Utility Menus Memories PREV for less Menu Num Heading Automation Function 64 set As 1 Set Pressing this will set the current Pow On system set up as the Power on Memory memory default 65 Recall 1 Recall Pressing this will recall The Power on Pow On memory set up in the last menu Memory 66 Total 1 Reset Pressing this will cause a first Birthday Reset of the unit All current memories and settings will be lost 67 BACK none Go To the Top Level Menus 20 eyeheight U
15. ght Unit 34 Park House Watford Business Park Greenhill Crescent Watford Herts GB WD18 8PH Reg No 2855535 Telephone 44 0 1923 256 000 Fax 44 0 1923 256 100 email eesales eyeheight com Menu Num 32 33 34 35 Heading ATAKE Levels T Time BACK Automation Menu Level A 1 Take A Aud Menu Level B 1 Take B Aud Menu Level A 0 1023 Menu Level B 0 1023 Menu Level A 1 200 Menu Level B 1 200 none Function This menu is for Automation systems use only This will start the A and B Embedded audio transition set by the next menus This sets the next audio level which will be achieved at the end of the transition started in the previous menu This sets the transition time in video fields from the current audio level to the next audio level Go To the Top Level Menus Menus 36 39 Utility Menus Nested Menus Menu Num 36 3 38 39 Heading Preview Set up Memories Back Automation none none none none Function Go To preview output menus 40 43 Go To system set up menus 44 47 Go To memory menus 48 51 Go To the main Utility menus 0 3 Menus 40 43 Utility Menus Safe Area Gen Menu Num 40 Heading SAFE ACTION Automation None Function This Switches on and off the currently selected area Pressing the Red switch next to this one and adjusting the rotary digipots with the lighted green LED s chooses the Sele
16. is shown a typical system consisting of an MW 3E in a flexiBox controlled by an FP 10 and a VP 10 maxiBox rear 5 E i eyeheight eyeheight Connect Pins 1 2 4 7 9 from chassis to panels 1 1 Use twisted pair AES Digital Audio cable for pins 2 and 7 Pins 1 4 9 carry power 0 5 Amp 13V Use cable with a least a 1 amp rating for pins 1 4 9 Cable llength should not exceed 250m l Bus pins 2 amp 7 The I BUS Network requires terminating with 100 Ohms at each extreme end of the network Ensure that this is done either by an external 100 ohm resistor OR ONE Panel Product at each end has the termination set See the Genetics User Guide Under the sections Flexipanel Power I BUS Jumpers For the 4RU Panels see 4RU Panel FP 10 Jumpers for BUS and 4RU Panel VP 10 SW 10 AP 10 Jumpers for I BUS Alternatively The termination can be set on a Product ie the MW 2 module Information about this is given in this manual Figure 2 3 l Bus Connections and Termination N B From 1 10 02 Eyeheight introduced a change in the Flexibox Chassis Most versions now have two 9 way connectors on the rear labelled I Bus and D Bus The Il Bus connector is the same as the previously labelled Can B connector 9 eyeheight Unit 34 Park House Watford Business Park Greenhill Crescent Watford Herts GB WD18 8PH Reg No 2855535 Telephone 44 0 1923 256 000 Fax 44 0 1923 256 100 email eesales eyeheight c
17. lexibox system with a Flexipanel and that the Flexibox has at least two spare slots above each other for the MW SE card 2 2 Installing the MW 3 into a flexiBox To install the MW 3E into a flexiBox it is desirable but not necessary to power down the flexi box Follow these instructions On the rear of the flexiBox are 6 slots for Products Remove any pair of spare blanking plates one above another There are 2 M2 5 Screws which require unfastening for each blanking plate Slide the Product PCB into the spare slots and firmly push it home Use the two thumbscrews to fasten the unit in place Take care that the ribbon cable for the upper circuit board stays attached to the lower board Now refer to the GeNETics User Guide If your system consists of a single flexiBox with a single flexiPanel then refer to the section titled flexiPanel Auto Set up If your system is part of a network with more than one flexiPanel then refer to the section titled flexiPanel Manual Set up This will guide you through acquiring your product as a device on the flexiPanel 7 eyeheight Unit 34 Park House Watford Business Park Greenhill Crescent Watford Herts GB WD18 8PH Reg No 2855535 Telephone 44 0 1923 256 000 Fax 44 0 1923 256 100 email eesales eyeheight com 2 3 Connecting Video to an MW 3 A Typical Connection diagram for the MW 3E is shown below All signals are SDI REF VERT op te A Input PGM Output P gt lt Loop MW
18. nit 34 Park House Watford Business Park Greenhill Crescent Watford Herts GB WD18 8PH Reg No 2855535 Telephone 44 0 1923 256 000 Fax 44 0 1923 256 100 email eesales eyeheight com 4 Technical Appendix 4 1 Technical Specification for the MW 3E 10 consisting of 3 Fixed Inputs and 6 Jumper BNC Connections Configurable outputs One BNC not used This is only guaranteed on issue 2 or later cards 4 2 Jumpering the I BUS CAN BUS Termination The I BUS Network is the control system under which all Products and Panels are networked together Under certain circumstances it is necessary to terminate the network This can be done on a Panel or a Product To terminate this product locate J6 on the MW 3E Processor Card supplied which is between U1 The large square chip and the Edge connector This is on the half of the card labelled CHP 100 Spartan2 Processor Jumper this with a 2mm link i J ha be yi tis fj SCC SCOP PPP rere 2 7 7 r ERD remme Si deh LEE FTR con ot ET ee bw ht r 4 a a j j P i di ee E Ly t T pi Ri et he a a i a b i gia z nk AT F 1 i x Pi TE i 4 i a T i F i i T y 4 i i a k e LEES i r i A z a fh oo he FOUR RCTR ae le 19 0120 Syo002 H a 4 i a a EA i i Mit Te a ae a Ae zie k wo ous b Ea zy E a oF j sei wOS9930 r all a 9893200d BH aH Figure 4 1 Location Of l Bus Termination Link ij Y BY arte AMOIGH
19. om 3 Operation 3 1 Manual control of the MW 3E Manual Control of the MW 3E is done using one or more of the following control surfaces e The 1RU FP 9 Flexipanel e The FP10 Desk mounting Panel e The VP 10 Desk mounting Video T BAR Manual Transition Panel e The TK 10 Desk mounting Manual TAKE Panel The FP 9 and the FP 10 have identical manual control ability The FP 10 is simply a desktop version of the FP 9 The VP 10 brings further functionality to the unit in the T BAR manual transitions and the other switch functions The MW 3E is as are all genetics modules controlled using a set of MENUS Each of these menus contains up to 3 parameters that are adjusted using the rotary digipots The Menus define all of the adjustable operational parameters in the MW 3E Pressing the rotary digipots brings the parameter to its default value Device selection is done using the device select switches which when pressed will offer the name of the device in the LCD Window Modules can be acquired and then de acquired using the set up switch For a full description of the operation philosophy of the geNETics system refer to the geNETics User Guide section Operation of the flexiPanel A full list of the Menus and their functions are given in section 3 of this chapter 3 1 1 Naming The Sources to the MW 3 The four named sources to the MW 3 can be renamed The sources are normally called Side A Side B Matte an
20. ows the Next selected On air InB 2 Matte Source A B matte or black 3 Black matte and black are internal sources 07 BACK none Go To the Top Level Menus Menus 08 11 VIDEO Transition Set up Menus NEXT for more Menu Num Heading Automation Function 08 TRANS a This sets the transition type between 2 Cut Mix Wipe and Cut and U and V ae fade types U and V fades 5 Fade Cut Transition to either Black or Matte PEP ANET AE and then Hold for a period before then transitioning to the Preset Source 09 TIME Menu Level A Press this button and the two digipots Menu Level B Indicated by the lit LED s will change ew the transition time in fields Tr and the Hold time in fields H
21. rom Eyeheight Ltd Factory Configurable Please Contact Eyeheight Ltd 23 eyeheight Unit 34 Park House Watford Business Park Greenhill Crescent Watford Herts GB WD18 8PH Reg No 2855535 Telephone 44 0 1923 256 000 Fax 44 0 1923 256 100 email eesales eyeheight com
22. t 34 Park House Watford Business Park Greenhill Crescent Watford Herts GB WD18 8PH Reg No 2855535 Telephone 44 0 1923 256 000 Fax 44 0 1923 256 100 email eesales eyeheight com 1 3 c2 Control Surfaces e A IRU control surface that fits on the Front of a 1RU Flexibox This is called a Flexipanel Order code FP 9 A Flexipanel can also be used in conjunction with a Minibox in this case the extra accessory Order code RR 9 will be required e A desk mounting control surface Order code FP 10 This unit is a modular unit which can be used in conjunction with the units below eyeheight o BUG oe rout ked 9 Figure 1 4 FP 10 desktop modular panel eyeheight C 066 O Do e Figure 1 5 VP 10 desktop modular T Bar eG eyeheight Unit 34 Park House Watford Business Park Greenhill Crescent Watford Herts GB WD18 8PH Reg No 2855535 Telephone 44 0 1923 256 000 Fax 44 0 1923 256 100 email eesales eyeheight com 2 Installation 2 1 Installation of the MW 3E product lf this unit is already pre installed in a Flexibox FB 9 with either a local or remote panel from the Factory then refer to the Hardware Installation Guide which will be enclosed with the system If this unit is pre installed in a Minibox MB 9 also refer to the Hardware Installation Guide which will be enclosed with the system If this unit has been ordered separately we assume here that you already have a F
23. tion Mixer and channel branding system In this case an AU 2 Automation card is also required Refer to the PresTX Product manual On most Flexiboxes later than 1 10 02 the RS422 port has been replaced by a D Bus Port The D Bus port is for High Speed data transfer and is not used for serial control In order to achieve serial control of any products on an l Bus network Eyeheight Ltd have developed a RS232 7 bus converter dongle DG 9 This enables greater flexibility of products on the Bus network whilst using the same protocols as the RS422 port 3 3 Operational Menus for the MW 3 menus below only apply for the MW 3E and MW 3EE units This is indicated Menus 00 03 Top Level Menus Menu Num Heading Automation Function 00 PLAY none Go To the main Play menus 4 7 01 VIDEO none Go To the main Video menus 8 23 02 AUDIO none Go To the main Audio menus 24 31 03 UTIL none Go To the main Utility menus 32 63 Il eyeheight Unit 34 Park House Watford Business Park Greenhill Crescent Watford Herts GB WD18 8PH Reg No 2855535 Telephone 44 0 1923 256 000 Fax 44 0 1923 256 100 email eesales eyeheight com Menus 04 07 PLAY Menus Menu Num Heading Automation Function 04 TAKE Do This Causes the Auto Transition to i occur 05 PROGM 0 nA This Shows the currently selected 2 Matte On air Source A B matte or black Maai matte and black are internal sources 06 PRSET 0 nA This Sh
24. tor Output lt 100mA Not Used General Purpose Output 6 GPO6 Open Collector Output lt 100mA PP eyeheight Unit 34 Park House Watford Business Park Greenhill Crescent Watford Herts GB WD18 8PH Reg No 2855535 Telephone 44 0 1923 256 000 Fax 44 0 1923 256 100 email eesales eyeheight com General Purpose Output 7 GPO7 Open Collector Output lt 100mA Indicates when Manual Overide of Audio Lead Lag IN is set Menu 80 General Purpose Output 8 GPO8 Open Collector Output lt 100mA Indicates when Manual Overide of Audio Lead Lag OUT Is set Menu 81 General Purpose Input 1 GPI1 Pull to Ground to activate Take TOA General Purpose Input 2 GPI2 Pull to Ground to activate 15 General Purpose Input 3 GPI3 Pull to Ground to activate User Programmable 16 General Purpose Input 4 GPI4 Pull to Ground to activate User Programmable 17 General Purpose Input 5 GPI5 Pull to Ground to activate User Programmable 18 General Purpose Input 6 GPI6 Pull to Ground to activate User Programmable 19 General Purpose Input 7 GPI7 Pull to Ground to activate User Programmable OR Audio Lead Activation GPI 20 General Purpose Input 8 GPI8 Pull to Ground to activate User Programmable OR Audio Lag Activation GPI Time Code Input LTC Balanced Not Used Time Code Input LTC Balanced Not Used 20 GND The GPI Scripter windows application is available f
Download Pdf Manuals
Related Search
Related Contents
TSL Timetable Sound Level Controller Fujitsu SCENICVIEW Series A19W-3 LC-007-001 od 101 User Manual LED DMX Controller KRAUS C-GV-690-19mm-15000CH Instructions / Assembly Copyright © All rights reserved.
Failed to retrieve file