User Manual Change Document
Contents
1. double clicking on the Craft Person Station icon in the Timeplex Apps window 7 Remove the CPS application disk from the drive and store it in a safe place 4 The Upgrading Operational Software paragraphs should read Upgrading Operational Software to Release 2 1 All instances of upgrading from Release 1 2 to Release 2 0 should read upgrading from Release 2 0 to Release 2 1 MX17233 1 8 of 9 7 31 97 DISCLAIMER Ascom Timeplex is now Timeplex Inc The new company logo is TimePlex Group Please disregard any references to the company s former name in this manual Thank you 1998 Timeplex Inc 01 01 98
2. CPS software may be named cps0211 exe Remove the CPS application disk from the drive and store it in a safe place Installing CPS Software Using Windows 3 1 To install the CPS software using Windows 3 1 1 Insert the CPS application disk RP66084 into the floppy disk drive a or b of the PC that will be used as the craft person station Start the CPS software installation by choosing File from the Program Manager window and then selecting Run from the menu Type the following in the Command Line a wininst or b wininst Then click on OK A dialog box appears informing you about the minimum system requirements To continue with the CPS installation click on the OK button NOTE You may abort the installation program at any time by clicking on the MX17233 1 7 31 97 Cancel button 7of9 4 You are next prompted to enter the Windows Groupname You may accept the default Groupname or choose your own After selecting the Groupname click on the OK button 5 You are next prompted to enter the destination drive and directory name You may accept the default drive directory or choose your own After selecting the drive and directory click on the OK button The CPS application program will now be installed This takes about one minute 6 A dialog box will appear signifying that the installation successfully completed Clicking on the OK button will cause the Timeplex Apps window to appear You may now start the CPS
3. setting the circuit breaker s on the power entry unit to the OFF position Slide the replacement LXM or RXM module into the module assembly close the ejector handles and tighten the locking screws Replace the bus extender cables A and B and lock them in place by tightening the locking screws If the shelf was powered down apply power to the shelf by setting the circuit breaker s on the power entry unit to the ON position For multishelf nodes logically insert the modules in each shelf beyond the shelf that was powered up using the CPS command ins shelf n where n shelf number Clear the RXM loopback in the preceding shelf with the CPS command clr rxm n where n shelf number 3 of 9 Chapter 9 Modules On page 9 32 the SGM Module Types information should be The three available SGM Module types are e SGM 1 SGM 1 e SGM 1 19 2K SGM 4 e SGM 1 128K SGM 3 Chapter 10 Cable Applications On page 10 22 callout 2 under V 24 RS 232 RS 530 Distribution Panels paragraph should read 2 100 pin cable connector from P1 4 or P5 8 connector on the SDM 8 V 24 or SDM 8 V 35 module See Table 10 8 for pin assignments Appendix B The information for the FSM 64 Module in Table B 4 should be Part Number Modus Description 65754 3 FSM 64 64 Port Frame Server Module The information for the SGM Module in Table B 4 should be Part Number Modus Description 65732 1 SGM 1 Subrate Groomer Module
4. 0 access device operational software RP66072 NOTE For important updated information following the printing of this manual refer to the accompanying Release Notes NOTE Throughout this manual the term ST node applies to models ST 1000 ST 50 and ST 20 Also throughout this manual the term LINK represents the following products e LINK 2 Integrated Connectivity System e LINK 2 Facilities Management System e miniLINK 2 Integrated Connectivity System e microLINK 2 Integrated Connectivity System MX17233 1 1997 1998 Timeplex Inc 7 31 97 1of9 e entr eLINK System e LINK 100 Integrated Connectivity System Chapter 2 ST 1000 Installation The following precaution note applies to the bottom of page 2 28 PRECAUTION Ifa Revision A RXM Module is being installed in an operational control shelf that previously contained only IRP Modules the shelf must first be powered down Otherwise all of the IRP Modules will be reset when the RXM Module is inserted The shelf must also be powered down when replacing a Revision A RXM Module Refer to the Adding and Replacing ST Units chapter for information on replacing RXM Modules Chapter 8 Adding and Replacing ST Units The procedure for replacing LXM and RXM Modules should be as follows Procedure 8 19 Replacing an LXM or RXM Module 2of9 This procedure replaces an LXM or RXM module in an ST 1000 node PRECAUTION When replacing an LXM or RXM mod
5. 56 64 Kbps 65732 3 SGM 1 19 2K Subrate Groomer Module 19 2 64 Kbps 65732 5 SGM 1 128K Subrate Groomer Module 64 128 Kbps MX17233 1 4of9 7 31 97 Appendix C Installing Operational Software All references to software filenames should be 0210 instead of 0201 For example Table C 1 should be Table C 1 ST 1000 ST 20 Release 2 1 Softwaret dsm These files are not required when installing software from a PC The filenames listed in this table are those of the initial release If a maintenance release of 2 1 software is required the filename will be different for example 3map021 1 0b MX17233 1 7 31 97 5 of 9 Appendix D Upgrading Operational Software 1 All references to software filenames should be 0210 instead of 0201 For example Table D 1 should be Table D 1 ST 1000 ST 20 Release 2 1 Softwaret dsm These files are not required when installing software from a PC The filenames listed in this table are those of the initial release If a maintenance release of 2 1 software is required the filename will be different for example 3map021 1 0b 2 In Procedure D 2 step 3 should read 3 Insert the Database Conversion Utility tape RP66086 into the tape drive 3 Procedure D 3 should read Procedure D 3 Installing Release 2 1 CPS Software The CPS application software is provided on a single 3 5 inch floppy disk The following procedure describes how to install the CPS software application on a PC u
6. TimePlex Group User Manual Change Document This change document revises information contained in the Synchrony ST 1000 ST 20 Bandwidth Management Installation and Maintenance Manual MC17233 The information in this document supports Release 2 1 of the Synchrony ST 1000 ST 20 Bandwidth Management System Insert this document directly after the title page of your manual as a record of the change s Front Matter 1 The Table of Modules information for SGM Module types should be Server Modules SGM 1 Subrate Groomer Module 56Kbps and 64Kbps AD 10 aggregates SGM 1 19 2K Subrate Groomer Module 19 2Kbps and 64Kbps AD 10 aggregates SGM 1 128K Subrate Groomer Module 64Kbps and 128Kbps AD 10 aggregates 2 Under Products Covered by This Manual the information should read This manual applies to the Synchrony ST 1000 and ST 20 bandwidth management systems and to the Synchrony AD 3 AD 7 and AD 10 access devices The ST 1000 accepts both bandwidth management modules and internetworking modules see the Table of Modules on the following page Information on ST 1000 operation using the internetworking modules is provided in the ST 1000 ER 5 Internetworking User s Guide Volumes I and 2 and in the ST 1000 ER 5 Internetworking Installation and Maintenance Manual e Craft Person Station distribution software RP66084 e ST 1000 and ST 20 bandwidth management system operational software RP66080 RP66081 RP66082 RP66083 e AD 1
7. application by double clicking on the Craft Person Station icon in the Timeplex Apps window 7 Remove the CPS application disk from the drive and store it in a safe place Installing CPS Software Using Windows 95 To install the CPS software using Windows 95 1 Insert the CPS application disk RP66084 into the floppy disk drive a or b of the PC that will be used as the craft person station 2 Start the CPS software installation by clicking on the Start button and selecting Run from the menu Then type the following in the Command Line a wininst or b wininst 3 A dialog box appears informing you about the minimum system requirements To continue with the CPS installation click on the OK button NOTE You may abort the installation program at any time by clicking on the Cancel button 4 You are next prompted to enter the Windows Groupname You may accept the default Groupname or choose your own After selecting the Groupname click on the OK button 5 You are next prompted to enter the destination drive and directory name You may accept the default drive directory or choose your own After selecting the drive and directory click on the OK button The CPS application program will now be installed This takes about one minute 6 A dialog box will appear signifying that the installation successfully completed Clicking on the OK button will cause the Timeplex Apps window to appear You may now start the CPS application by
8. sing DOS Windows 3 1 or Windows 95 MX17233 1 6 of 9 7 31 97 Installing CPS Software Using DOS To install the CPS software using DOS 1 Insert the CPS application disk RP66084 into the floppy disk drive a or b of the PC that will be used as the craft person station 2 Start the CPS software installation utility by entering the following command at the DOS prompt a dosinst or b dosinst 3 A dialog box appears informing you about the minimum system requirements To continue with the CPS installation press the Enter key NOTE You may abort the installation program at any time by pressing the Esc 4 You a prompted to enter the destination drive and directory name You may accept the default drive directory or choose your own After selecting the drive and directory press the Enter key The CPS application program will now be installed This takes about one minute 5 A dialog box will appear signifying that the installation successfully completed Pressing either the Enter key or Esc key will take you to the CPS directory Enter the dir command to view the files installed in the CPS directory One file will be named cps0210 exe or something similar This is the executable file that you will use to start the CPS application NOTE The filename cps0210 exe only applies to the initial release of CPS 6 software If a maintenance release is required the file name will be different For example the first maintenance release of
9. ule all modules and associated interfaces in the same shelf are interrupted as well as all modules in the shelves beyond the removed LXM or RXM Therefore replacement should be scheduled for non busy times and users should be informed of the interruption Initiate a loopback on the RXM module in the shelf preceding the shelf that contains the LXM or RXM module that is to be replaced by entering the command lp rxm n where n shelf number NOTE All modules on any downstream shelves are disconnected when the RXM module is placed in loopback For multishelf nodes logically remove the modules in each shelf in succession beyond the powered down shelf using the CPS command rmv shelf n where n shelf number For multishelf nodes disconnect the front panel upper A and lower B bus extension cables from the RXM or LXM module to be replaced by loosening the cable connector locking screws and removing the cables Tag the cables if necessary MX17233 1 7 31 97 4 Remove the failed LXM or RXM module by loosening the module locking screws opening the ejector handles and sliding the module from the module assembly PRECAUTION Ifthe replacement module is a Revision A RXM Module 10 MX17233 1 7 31 97 and the shelf contains one or more IRP Modules the shelf must first be powered down Otherwise the IRP Modules in the shelf will be reset upon insertion of the RXM Module If necessary power down the shelf by