Home
Free Joint Multi Air Conditioner
Contents
1. Result The indoor unit beeps each time you press the button The air conditioner runs in the Auto mode The Auto mode cools or heats the room depending on the set temperature The air conditioner changes the Cool or Heat mode automatically depending on the current temperature during operation Note You can change modes at any time 3 Press the button to adjust the temperature until the required temperature is displayed You can set the temperature between 61 F 16 C and 86 F 30 C Result Each time you press the V A button The temperature is adjusted by 1 F The indoor unit beeps 4 To control the airflow direction refer to page 21 Oke D Selecting Cool Mode You can select the Cool mode if you want to cool your room You can adjust the temperature and the fan speed when cooling ower 1 If necessary press the ZN button Result The operation indicator on the indoor unit lights up The air conditioner starts up in the mode you selected last The indoor unit beeps Y 7 i Fan 4 y Saving Flap SET TEM Us F ke Mode P 2 Press the O button on the remote control until e 4 is displayed Mode Result The indoor unit beeps each time you press the O button 4 The air conditioner runs in the Cool mode Note You can change modes at any time 3 Press the J A button to adjust the temperature un
2. F The indoor unit beeps oo f ENGLISH Temperature changes in good sleep mode To prevent excessive cooling heating during sleep the good sleep mode automatically modifies the temperature setting in accordance with the time setting Temperature and air current change according to the three stages Falling asleep Sound sleep and Waking up from good sleep mode and then the air conditioner will automatically turn off when the set time has elapsed Three stage good sleep prevents you from having difficulty sleeping on extremely hot cold nights Falling asleep Eases you into sleep by dropping the temperature Sound sleep Relaxes your body and raises your temperature slightly Waking up from good sleep mode Allows you to wake up to comfortable crisp air making you feel refreshed and energized Set the Off timer in good sleep mode for more than 5 hours Sleep may be disturbed if the good sleep mode is set for too short or too long a time because the temperature changes are set to an 8 hour cycle If the good sleep mode is set for less than 4 hours the operation will stop at the set time If the good sleep mode is set for over 5 hours the last hour will run in Waking Up stage before shutting off Recommended set temperature is between 77 F 81 F for cooling and 69 8 F 73 4 F for heating Cool mode Temp 4F 2F Set temperature When the 8 hour cycle completes
3. You can set the temperature between 61 F 16 C and 86 F 30 C Result Each time you press the 7 A button The temperature is adjusted by 1 F The indoor unit beeps If the room temperature reaches 9 F higher than the set tempera ture the air conditioner stops heating but the fan operates consis tently If the room temperature reaches 5 F lower than the set temperature the air conditioner starts heating again Fan 4 Press the O button to select the fan speed until the required setting is displayed Rus Automatic rotated Q a gt Kuat oh Low San Medium oR aal High atl Maximum Result o Each time you press the button the indoor unit beeps For the first 3 5 minutes the fan may not operate to prevent V the cool air from running out of the indoor unit It helps to warm the air in your room sufficiently Cf lt an y y Saving Flap aood sleen 5 Tocontrol the airflow direction refer to page 21 Selecting Dry Mode You can select the Dry mode if you want to dehumidify your room You can adjust the temperature in this mode 1 If necessary press the button Result The operation indicator on the indoor unit lights up The air conditioner starts up in the mode you selected last The indoor unit beeps Mode E 3 EETA 2 Pressthe button on the remote control until is displayed Mode Result The indoor unit beeps each time you press th
4. disappears Mode 3 Press the button until the desired mode is displayed at the top of the remote control to select the mode in advance Battery Result The air conditioner operates in the selected mode when it is turned on Note If you don t use the remote control after setting the On Timer it turns off automatically after 25 hours To Cancel the On Timer Set Cancel Press the ry button to cancel the On Timer Noga If you press the ry button both the On Timer and the Off Timer are canceled Battery Setting the Off Timer ENGLISH You can set the Off Timer to turn off the air conditioner automatically at the appointed time You can set the time from 1 hour to 24 hours 1 Press the button until the required time is displayed to set the Off Timer You can set the time between 1 hour and 24 hours Set Cancel 2 Press the Result The remaining time is displayed 4 The timer indicator stops blinking 4 The air conditioner turns off automatically at the appointed time and the Off Timer setting disappears button to complete the setting Bama If you would like to turn the air conditioner on after 2 hours and to operate it for 2 hours 1 Press the button until 2 Hr is displayed Set Cancel 2 Press the O button OFFS 3 Press the button until 4 Hr is displayed Set Cancel 4 Press the button Note You can check or
5. manner gt Install the air conditioner avoiding direct sunlight or heater especially water gt Install the outdoor unit so as to let the discharged air out properly Avoid a place that may disturb your neighbor by noise gt Install the drain hose to let the water run safely and correctly ENGLISH CAUTION REGARDING POWER SOURCE gt Disconnect the circuit breaker gt Contact the service center or gt Contact the service center when you don t use the manufacturer if you wantto O after turning off the air air conditioner for a long time repair the air conditioner conditioner if strange noise to save energy is heard burning smell or smoke blow DURING OPERATION gt Do not open the front grille gt Avoid cold and hot air b Avoid the water from during operation reaching to person petora getting into the plant directly for a long time air conditioner 75 gt Do not use the air conditioner b Do not step on the air gt Do not drink the water from for a long time in a closed room conditioner or put heavy the air conditioner or in a place where there sa object on it 5 baby or an old person CAUTION DURING OPERATION gt Do not touch the pipes Do not use the air conditioner Do not give excessive shock connected to the air to maintain the machine fo
6. this section eae repeats 4 F 1 2 3 4 5 6 7 8 Time hr Heat mode When the 8 hour cycle completes this section repeats 1 2 3 4 5 6 7 8 Time hr Selecting the Turbo Function You can select the Turbo Function if you want to cool or heat your room in the fastest way After the 30 minute operation with the maximum setting it returns to the previous setting 1 If necessary press the 5 button Result 4 The operation indicator on the indoor unit lights up 4 The air conditioner starts up in the mode you selected last The indoor unit beeps 2 Press the button Result 4 The temperature and fan settings are adjusted automatically 4 The air conditioner cools or heats the room as quickly as possible After 30 minutes the air conditioner is reset automatically to the previous setting You can select the Turbo function in the Auto Cool and Heat mode If you select this function in the Dry or Fan mode the mode changes to the Auto mode 3 Press the 7 button again to stop the Turbo Function before the end of the 30 minute period Result The air conditioner is reset automatically to the previous setting 4 To control the airflow direction refer to page 21 Adjusting the Airflow Direction Vertically ENGLISH You can adjust the airflow direction vertically The outer airflow blade moves up and down to increase the efficiency of the cooling or heating operation
7. Contents PREPARATION m Safety Precautions ccssessscsessssseesesssseeesssssssesessessssseessessssssessasssseseesensseeeessnssessees 3 m Name of Each Part 8 m Remote Control Buttons and Display m Inserting the Remote Control Batteries m Getting Started OPERATION E Selecting ALCO MOJE Sasa iassasacicdscessasacsdscsnsssstaecasbsnssvaasusstesscatus osssusansieacnbcuabestcte 13 m Selecting Cool Mode m Selecting Heat Mode m Selecting Dry Mode m Selecting Fan Mode m Selecting Good Sleep Mode m Selecting the Turbo Function m Adjusting the Airflow Direction Vertically m Adjusting the Airflow Direction Horizontally m Setting the On Timer m Setting the Off Timer m Operating Your Air Conditioner Without the Remote Control 24 RECOMMENDATIONS FOR USE m Cleaning Your Air Conditioner m Cleaning Deodorizing and Bio filter Option m Temperature and Humidity Ranges m Operating Recommendations m Solving Common Problems m Periodical Checks m Protections enabled by the Unit control system wessssssssseesssssseeseessesseesessseesees 29 Correct Disposal of This Product Waste Electrical amp Electronic Equipment i Applicable in the European Union and other European countries with separate collection systems This marking shown on the product or its literature indicates that it should not be disposed with other household waste at the end of its wor
8. ISH Selecting Good Sleep Mode Good Sleep mode helps users to fall asleep well after going to bed whether being too hot to sleep or being awakened by coldness The Good Sleep mode can be selected only when the air conditioner is switched on in cool heat mode 1 If necessary press the 4 button Result 4 The operation indicator on the indoor unit lights up The air conditioner starts up in the mode you selected last The indoor unit beeps Mod f 2 Press the button to select or mode Result The indoor unit beeps each time you press the button The air conditioner runs in cool or heat mode 3 good sleep Fi 7 E Press the O button until the 2 indicator appears on the remote control Inthe case of adjusting time Press the button to adjust desired operation time from 1 to 12 hours Good Sleep mode will automatically stop after the set time Set Cancel Press the button Result In the case of adjusting the extra time for Good Sleep mode you should press the 9 button within 10 seconds If you do not press the 5 button within 10 seconds Good Sleep mode will automatically stop in 8 hour operation 4 Press the button to adjust the temperature until the required temperature is displayed You can set the temperature between 61 F 16 C and 86 F 30 C Result Each time you press the V A button The temperature is adjusted by 1
9. bine e FLAP ee 1 Press the O button until the required direction is set oh Result The outer blade is adjusted vertically ead Flap A d sleep FLAP F e On 2 Press the O button to move the blade up and down automatically during operation FLAP 3 Press the O button again to stop the blade moving up and down Nota If you turn the air conditioner Then the blade off is closed completely on set to the default position Adjusting the Airflow Direction Horizontally You can adjust airflow direction horizontally manually The inner blades with small fins move the air in the desired direction 1 Adjust the inner blades by moving them left or right Make sure do not touch the inner blades during operation It may cause injury on your fingers Setting the On Timer You can set the On Timer to turn on the air conditioner automatically at the appointed time You can set the time from 1 hour to 24 hours 1 Press the button until the required time is displayed to set the On Timer You can set the time between 1 hour and 24 hours Set Cancel 2 Press the O button to complete the setting Result The remaining time is displayed The timer indicator stops blinking The selected mode and the temperature on the display disappear after 10 seconds 4 The air conditioner turns on automatically at the appointed time and the On Timer setting
10. change the mode and or the temperature by pressing the o button or the Y A button after setting the Off Timer To Cancel the Off Timer Set Ci Press the ry button to cancel the Off Timer Set Cancel Note If you press the button both the On Timer and the Off Timer are canceled Operating Your Air Conditioner Without the Remote Control Your air conditioner can be operated directly from the indoor unit if the remote control is lost or broken 1 To switch the air conditioner on press the ON OFF switch on the right side of the indoor unit Result The OPERATION indicator on the indoor unit comes on The indoor unit beeps The air conditioner starts up in the most suitable mode for the room temperature The mode may change from cooling into heating from heating into cooling depending on the current temperature during operation Room Temperature Operating Mode Less than 75 2 F Heat 75 2 F or above Cool 2 To switch the air conditioner off press the ON OFF switch again Even if the air conditioner has been switched on via the ON OFF switch operations can still be controlled using the remote control as usual Cleaning Your Air Conditioner ENGLISH To get the best possible use out of your air conditioner you must clean it regularly to remove the dust that accumulates on the air filter PORTANT Before cleaning your air conditioner ensure that y
11. ctly Note Use two AAA LRO3 1 5V batteries Do not use old batteries or different kinds of batteries together Batteries may be completely discharged after 12 months even if they have not actually been used 1 Remove the battery cover in the rear of the remote control by pushing it with your thumb 2 Insert two batteries respecting the polarities as indicated by the and symbols 3 Close the cover by sliding it back in its place Getting Started The User s Manual provides you with valuable information about your air conditioner In order to take full advantage of the air conditioner s features please read this manual carefully before using You have already seen the basic description of the unit on pages from 8 to 10 Starting with the next page you will find a series of step by step procedures for each function available The illustrations in the step by step procedures use three different symbols PRESS PUSH HOLD DOWN Selecting Auto Mode ENGLISH You can select the Auto mode if you want to cool or heat your room automati cally You can adjust the temperature and the fan speed in this mode ower 1 If necessary press the e button Result 4 The operation indicator on the indoor unit lights up The air conditioner starts up in the mode you selected last The indoor unit beeps Mode E a 2 Press the O button on the remote control until Lae is displayed
12. dence of SAMSUNG product problem ENGLISH Periodical Checks Description Monthly Every 4 months Once a year Indoor unit Clean the air filter 1 Clean the condensate drain pan 2 Thoroughly clean the heat exchanger 2 Clean the condensate drain pipe 2 Replace the remote control batteries Outdoor unit Clean the heat exchanger on the outside of the unit 2 Clean the heat exchanger on the inside of the unit 2 Clean the electric components with jets of air 2 Verify that all the electric components are firmly tightened 2 Clean the fan 2 Verify that all the fan assembly is firmly tightened 2 Clean the condensate drain pan 2 3 amp The checks and maintenance operations described are essential to guarantee the efficiency of the air conditioner The frequency of these operations varies according to the characteristics of the area the amount of dust etc 1 The described operations should be performed more frequently if the area of installation is very dusty 2 These operations must always be performed by qualified personnel For more detailed information see the Installation Manual Protections enabled by the Unit control system ENGLISH Type of protection Description Operation When it enables Heating on heat pump During operation Protection against cold air The internal fan is off Heating on heat
13. e button The air conditioner runs in the Dry mode Notte You can change modes at any time 3 Press the 7 A button to adjust the temperature until the required temperature is displayed You can set the temperature between 61 F 16 C and 86 F 30 C Result Each time you press the Y A button The temperature is adjusted by 1 F The indoor unit beeps The air conditioner starts dehumidifying and the fan speed is adjusted automatically 4 To control the airflow direction refer to page 21 Selecting Fan Mode You can select the Fan mode if you want to ventilate your room It helps to refresh the air in your room You can adjust the fan speed in this mode Power 1 If necessary press the button Result The operation indicator on the indoor unit lights up The air conditioner starts up in the mode you selected last The indoor unit beeps 2 Mode N a Press the O button on the remote control until 1 is displayed Mode Result 4 The indoor unit beeps each time you press the O button 4 The air conditioner runs in the Fan mode The temperature is set automatically Note You can change modes at any time Fan 3 Press the button to select the fan speed until the reguired setting is displayed oh Low San Medium atl High r Result Each time you press the button the indoor unit beeps 4 To control the airflow direction refer to page 21 ENGL
14. eating performance of air conditioner will decrease If you find that the room is not warm enough using an additional heating appliance is recommended Warm air circulation The air conditioner circulates warm air to heat your room It will take some time to warm the air in your room entirely after the air conditioner turns on Therefore turn the air conditioner on in advance Frost When outdoor temperature is low but humidity is high frost may form on the outdoor unit at Heat mode 4 The heating operation stops The defrost mode will be triggered automatically for 3 to 14 minutes No intervention is required after about 7 minutes the air conditioner operates again normally High indoor and outdoor temperatures If both indoor and outdoor temperatures are high and the air conditioner is running at HEAT mode the outdoor unit s fan and compressor may stop at times This is normal simply wait until the air conditioner switches on again Power failure If a power failure occurs while the air conditioner is operating the unit will be switched off When the power returns the air conditioner starts up again automatically Protection mechanism When the air conditioner is started immediately after being plugged in or stopped the normal operation starts up after 3 minutes for the reason of protection Cooling operation The indoor unit may not get the selected fan speed such as Medium and Low under cooling o
15. es the temperature and humidity ranges the air conditioner can be operated within Refer to the table for efficient use MODE OPERATING CONDITIONS IFOUT OF CONDITIONS Indoor temp 60 8 F 89 6 F A safety device will stop continuously the system functioning COOL Indoor humidity below 80 Condensation may occur on the indoor unit with risk to have either water blow off or drops Outdoor temp 23 F 109 4 F on the floor HEAT Indoor temp below 80 6 F A safety device will stop continuously the Outdoor temp 59 F 75 2 F system functioning Indoor temp 60 8 F 89 6 F A safety device will stop continuously the system functioning DRY Indoor humidity below 80 Condensation may occur on the indoor unit with risk to have either water blow off or drops Outdoor temp 23 F 109 4 F on the floor POWER SUPPLY Single phase rated voltage l 208V 220V 60M2 minimum and maximum limit 187V min 253V max Xx Any damage occurs out of condition specified cannot be covered by product warranty If the system works continuosly outside of conditions its performace and reliability will be compromised Operating Recommendations Here are a few recommendations that you should follow when using your air conditioner Topic Recommendation Heating performances The heat pump function of the air conditioner absorbs heat from outside air and brings it indoors As the temperature of the outside air drops the h
16. f button MH FN A Series Mi MHOSOFXCA2A Air Inlet Rear Air Outlet Connection Valve Inside Mn MHOBOFXCA4A Air Inlet Rear Connection Valve Inside ENGLISH Remote Control Buttons and Display Transmission indicator Temperature and Timer setting 1 Hour Timer indi our Timer indicator Battery life indicator On Timer indicator Off Timer indicator Operation modes indicator Law AUTO S amp COOL DRY fp FAN HEAT Turbo function indicator Airflow direction Sleep mode indicator Fan speed amp Silence indicator Energy saving indicator Turbo button Power On Off button 1 Hour Timer button Mode selection button AUTO COOL DRY FAN HEAT Temperature adjustment button Fan speed adjustment button amp Silence mode button Energy Saving button Airflow control button Good Sleep button On Timer button Timer Set Cancel button Battery check button Off Timer button Note Each mode indicator shows the current setting and the battery life You can check the battery life by pressing the O button The number of the battery life indicator means the remaining battery life Replace the batteries when only one battery life indicator remains Inserting the Remote Control Batteries ENGLISH You must insert or replace the remote control batteries when You purchase the air conditioner The remote control does not work corre
17. igh lightning rod or telephone outer wall or outside ofthe earth terrace gt The installation must be carried out by a licensed installer or qualified personnel when installing the unit for the first time or reinstalling it gt Contact the service center if the air conditioner is under water REGARDING POWER SOURCE gt Do not pull the electric wire gt Install the switch and circuit or touch the power plug with o breaker only for the wet hands air conditioner N N gt Do not bend the electric wire gt Use the power source with gt If the power plug is by force or weigh down the separate wiring only for air damaged replace it by the air conditioner not tobe out Oo conditioner manufacturer or qualified of order personnel to avoid the risk ENGLISH A WARNING DURING OPERATION gt When using a wireless remote control the distance should not be more than 7 meters from the air conditioner If applicable gt Do not attempt to repair move modify or reinstall the unit on your own Make sure that these installations gt Never spill any kind of liquid into the unit Should this happen unplug or main switch off the unit and contact an authorized are carried out by qualified personnel to avoid electric shock or fire gt Do not place any obstacles in front of the unit Make sure that the unit is correctly ventilated at all
18. king life To prevent possible harm to the environment or human health from uncontrolled waste disposal please separate this from other types of waste and recycle it responsibly to promote the sustainable reuse of material resources Household users should contact either the retailer where they purchased this product or their local government office for details of where and how they can take this item for environmentally safe recycling Business users should contact their supplier and check the terms and conditions of the purchase contract This product should not be mixed with other commercial waste for disposal Register your product at www samsung com global register Safety Precautions The following safety precautions are provided to protect the users safety and prevent property damage Make sure to read the followings and use the air conditioner properly D Keep this user s manual together with the installation manual in a handy place so that you can find it whenever you need to see it after reading this manual thoroughly N WARNING This indicates the possibility of serious injury or death N CAUTION This indicates the possibility of serious injury or damage to environments when operated incorrectly WHEN INSTALLING gt Do not install the unit in a gt Do not connect the ground place where it isexposedto unitwherethere stheriskof to a gas pipe water pipe inflammable gas leakage dropping such as on h
19. od to the air conditioner conditioner pet plant or cosmetics OTHERS wv gt Be sure that the air filter not to gt The appliance is not intended gt The maximum input power amp be exposed to direct sunlight for use by young children or O current is measured infirm persons without according to the IEC standard supervision Young children Oo and the input power amp current should be supervised to o smeasured according to the ensure that they do not play ISO standard with the appliance gt Turn off the air conditioner and if the fan stops to operate clean the air conditioner gt Do not clean the air The surface of the heat conditioner by spraying water exchanger is sharp so be directly or with benzene careful of it when cleaning thinner or alcohol gt Dispose of the packaging gt All of the manufacturing and material in accordance with packaging materials used for your the local requirements o new appliance are compatible i with the environment and can be gt Be sure to insert the air filter gt recycled ENGLISH Name of Each Part The design and shape can be changed according to the model bm Temperature sensor Power On Off button Air filter Air flow blades under the grille outlet Operation indicator GREEN Timer indicator GREEN RED Power On Of
20. ou have switched off the breaker used for the unit 1 Open the upper front grille by pulling the lower right and left tabs of the grille 2 Pull air filters out of each tab of the grille 3 Remove all dust on the air filters with a vacuum cleaner or brush 4 When you finished insert air filters by fixing it to each tab of the grille 5 Toclose the front grille fix it to hooks and push down the lower right and left tabs of the grille 6 Clean the front grille with a damp cloth and mild detergent do NOT use benzene solvents or other chemicals Front grille J lt l Noga If you have not used the air conditioner for a long period of time adi Hook set the fan going for three to four hours to dry the inside of the air conditioner thoroughly pi Ef Cleaning Deodorizing and Bio filter Option Toremove minute dust particles and odors deodorizing and Bio filter are installed in the air conditioner You should clean the filters every 3 months f 1 Open the upper front grille by pulling the lower right and left tabs of the grille Deodorizing Filter 2 Pullout the deodorizing and Bio filter 3 Wash the filters with clean water then dry them in the shade Bio Filter 4 Insert the filters into the original position You can change the position of filters with each other 5 Close the front grille Temperature and Humidity Ranges The table below indicat
21. peration at very low outdoor temperatures for the protection of the indoor unit from ice or frost During Low fan speed operation cooling performance will be reduced If the room does not be cooled down when using Low fan speed operation please adjust the indoor unit s fan speed Solving Common Problems Before contacting the after sales service perform the following simple checks They may save you the time and expense of an unnecessary call Problem Explanation Solution The air conditioner does not Check if power is on and operate the air conditioner again operate at all Check if the circuit breaker is switched off Check if Off Timer is set The temperature is not adjusted Check if you selected the Fan mode The air conditioner does not operate Check if the air conditioner is cooling only model in the HEAT mode Check if the remote control is for cooling only model The cool warm air does not come Check if set temperature higher lower than current temperature out from the air conditioner Check if you selected the Fan mode Select the Cool Heat Auto or Dry mode Check if the air filter is blocked by dirt Clean the air filter regularly Check if the there is cover on the outdoor unit or any obstacle Remove the cover or obstacle Check if you installed the air conditioner under direct sunlight The window or door may be opened Check if you turn on the air conditioner j
22. pump During operation Defrost cycle The internal fan is off Cooling During operation Anti frost protection il The compressor is off of internal battery At start up or during the selection of the operating mode The start of the Cooling or heating Delayed start of compressor y P compressor is delayed on heat pump CAUTION If the air conditioner is operating in heat pump mode it performs several defrost cycles in order to remove the frost that may have deposited on the outdoor unit at low temperatures In this case the internal fan is switched off automatically and restarted only after the defrost cycle is completed ELECTRONICS If you have any comments or guestions regarding Samsung products contact the SAMSUNG customer care center Samsung Electronics America Inc 1 800 SAMSUNG 7267864 www samsung com lt p USER S MANUAL Free Joint MH FNCA Series ESPANOL ENGL SH FRAN AIS Free Joint Multi Air Conditioner Cooling and Heating INVERTER DOF DB98 29162A 1
23. til the required temperature is displayed You can set the temperature between 61 F 16 C and 86 F 30 C Result Each time you press the V A button The temperature is adjusted by 1 F The indoor unit beeps If the room temperature is higher than the selected temperature the air conditioner starts cooling If the room temperature reaches the set temperature the air conditioner stops cooling but the fan operates consistently aood sleen Fan 4 Press the button to select the fan speed until the required setting is displayed Kit Automatic rotated 9 Kia Quat Low Hi va Medium of l High Fan Result Each time you press the O button the indoor unit beeps 5 Tocontrol the airflow direction refer to page 21 Selecting Heat Mode You can select the Heat mode if you want to heat your room You can adjust the temperature and the fan speed when heating ENGLISH 1 If necessary press the 5 button Result The operation indicator on the indoor unit lights up The air conditioner starts up in the mode you selected last The indoor unit beeps Mode oe 2 Press the O button on the remote control until o is displayed Mode Result The indoor unit beeps each time you press the O button The air conditioner runs in the Heat mode Nowe You can change modes at any time 3 Press the 7 A button to adjust the temperature until the required temperature is displayed
24. times Do not place clothing or other materials over it gt Do not insert anything between the air outlet blades because the inner fan may be damaged and could cause injury Keep children away from the unit service center gt If the wireless remote control is not used for along time remove the batteries If applicable gt The manufacturer declines any liability for damage resulting from modifications or errors in the electrical or hydraulic connections heater to the air conditioner or repair it with your discretion gt Failure to observe the installation instruction or use of the unit under conditions other than those indicated in the table Operating limit of the unit installation manual will immediately invalidate the unit warranty gt Do not place any materials so that children cannot step on it K N N DISPOSING THE UNIT Gi gt Before throwing out the device it is necessary to pull back the battery cells and get rid of them safely for recycling reasons CAUTION WHEN INSTALLING gt When you need to dispose of the unit consult your dealer If pipes are removed incorrectly refrigerant may blow out and come into contact with your skin causing injury Releasing refrigerant into the atmosphere also damages the environments gt Please recycle or dispose of the packaging material for this product in an environmentally responsible
25. ust now It takes about 3 minutes to cool or heat the room Check if the drain pipe is too long The fan speed is not adjusted In Dry mode the fan speed is selected automatically The remote control does Check if the battery is discharged Replace the battery not operate Check if the remote control sensor is blocked Check if the air conditioner is placed near strong light The Timer is not set Check if you pressed the G button after selecting time Odor is permeated in the Check if you use the air conditioner in smoky area or there is a smell room during operation Ventilate the room or select the Fan mode for 1 2 hours The indoor unit indicator Press the amp button to turn on the air conditioner again flashes Switch the circuit breaker off and switch on it again Strange sound is heard from The sound is heard when the refrigerant gas flow is changed depending the air conditioner on the use of the air conditioner When you press the G9 button noise may be heard that the air conditioner sense the airflow blade Water drops from the outdoor Water may form due to the difference of the temperature unit connection part AUTO DIAGNOSTIC FUNCTION This air conditioner has an auto diagnostic function in case a failure will happen Occurring error the Lamp is blink Before contacting customer call center green number please ask to installer to make a double check of installation unless there s a full evi