Home

3. SBMS 환경 설정 및 실행

image

Contents

1. Click Search from Main Menu to open Prescription Search In Detail window Empty all the categories blank Click Find all to return to the whole list in the Archive In order to search Sample Databases in a certain date only first blank next to Date needs to be filled with the specific date In order to search Sample Databases in a certain age only first blank next to Age needs to be filled with the specific age For all the categories except Age Sex and Remote search system allows users to find any Sample Databases containing the word s that the users filled in within the category For example if the user typed This is in Adi info 1 category the user will find any Sample Databases such as Databases containing This is Sample and This is a test in their Adi info 1 if there are such Sample Databases All Rights Reserved www MD Best com SBMS 2 0 User Manual 6 12 MicroDigital Co Ltd Pulling Pulling Record Barcode Search Pulling Record No of sample Requested by Sample Information Total Ho 3 Total Yol In No Remain 3 Frescription Information Patient ID Ina Prescription Dept fad Hame Age Information of the sample name Prescription Or las IE Location 1 12 1234 12 IN Remote Request IN r Pulling Date No of Pull Pulling Date No of Pulling Requested by Al
2. Ltd 3 ODBC Setup for Windows 7 For Windows 7 32bit Programs 1 a Data Sources ODBC Click Start button Control Panel 1 Set up data sources ODBC 2 Type ODBC in search and press Enter to open ODBC Data Source Administrator window O See more results Shutdown gt For Windows 7 64bit Organize Include in library v Share with J AppPatch Name 4 Open a Windows Explorer J assembly BJ objsel di J Boot 2 occache dil J Branding amp ociw32 dll w m 7 2 ociw32 Go to SysWOW64 folder in J crystal ae 5 J Loka m7 ocsetup exe Windows folder J debug 3 odbc32 dll Ju diagnostics 2 odbc32gt dil 3 Double click odbcad32 application to open IB Downloadaa Tiara 2 odbcbcp dil Jo Drivers 2 odbcconf dil ODBC Data Source Administrator window J ehome l odbcconf exe D 80 items y CAUTION For ODBC setup in Windows 64bit users may open ODBC Data Source Administrator by following the steps for Windows 7 32bit above but you CANNOT add proper contents therefore make sure to follow proper protocol 15 All Rights Reserved www MD Best com SBMS 2 0 User Manual M2 MicroDigital Co Ltd Attention After the ODBC Data Source Administrator window is open please follow steps below User DSN System DSN File DSN Drivers Tracing Connection Pooling About User Data Sources
3. Sample Banking Manag Installation of SBMS ENG ivers 0 Sample banking Management Software completed 4 Click Ok to close the window Installation complete Attention For Windows 7 and VISTA users Please continue to additional steps below Microdigital Co Ltd f SBMS2 0 File Edit View Favorites Tools Help Back wi po Search gt Folders E Address C Documents and Settingsiyang bangsic Start Menu Programs SBMS2 0 AN SBMS2 0 SBMS2 0 Uninstall File and Folder Tasks Shortcut Shortcut 1 KB 2 KB CJ Make a new folder K Publish this Folder to the Web 2 Share this folder Other Places 2 Atte nt O n Programs 5 My Documents Shared Documents Default Shortcut Location on Start Menu 19 My Computer My Network Places Start gt Program gt SBMS2 0 Details Attention Additional steps for Windows 7 and VISTA 5 Locate LPr zip file in the provided CD 6 Extract the LPr zip file to SBMS2 0 folder CAUTION Make sure the files compressed in LPr zip file have transferred directly to SBMS2 0 folder NOT to any subdirectories in SBMS2 0 folder 11 All Rights Reserved www MD Best com SBMS 2 0 User Manual 12 MicroDigital Co Ltd 2 ODBC Setup for Windows XP Attention ODBC needs to be set before execute the program ODBC Data Source Administrator User DSN System DSN File DSN Drivers Tracing Connection Pooli
4. Version 4 TCP IPv4 Properties window www MD Best com SBMS 2 0 User Manual Internet Protocol Version 4 TCP IPw4 Properties General You can get IP settings assigned automatically if your network supports this capability Otherwise you need to ask your network administrator for the appropriate IP settings Obtain an IP address automatically KEN i i i IP address 1932 188 0 115 Subnet mask 255 255 255 0 Default gateway 1932 168 0 113 Obtain DNS server address automatically Use the following DNS server addresses Preferred DNS server Alternate DNS server C Validate settings upon exit 12 MicroDigital Co Ltd Select Use the following IP Address and set IP Address to 192 168 0 115 Subnet Mask values will automatically appear Do NOT touch Set Default Gateway to 192 168 0 113 Click OK and save and close 2 SBMS Software Installation amp ODBC Setup 1 Installation Double click on SBMS ver2 0 icon in SBMS CD For Windows XP to start the installation of SBMS Software Right click on SBMS ver2 0 in the CD For Windows 7 2 Click on Run as administrator All Rights Reserved Troubleshoot compatibility Share with Pin to Taskbar Pin to Start Menu Restore previous versions Send to Cut Copy Create shortcut Delete Rename Properties ver2 0 9 www MD Best com SB
5. Comment Test Adi info Users can also search Sample Databases Adi info em TT by scanning the barcode from the sample ingi nios I Info 5 T clicking on search to fill barcode values in Barcode Input and 21 All Rights Reserved www MD Best com SBMS 2 0 User Manual 12 MicroDigital Co Ltd Prescription Registration Barcode Input Search_ Users can fill in Sample Type manually Manual Input Patient ID korea however users can also assign Sample Types Name kin BT en as in Config to select them by scrolling down jw Personal ID e Users can also assign Diagnosis Names in Config to select them by scrolling down Prescription Dr Lee Pre e When users click on any boxes for Location ts igi Total No of segments JP Total sample volume Ilmi Remark Test Comment Test Adi info values will automatically appear which are the values from the last registration therefore users can follow the last Sample Database Adi info Adi info registration Adi info Adi info If users have selected assigned sample type in be filled to proceed Sample Type category values from the 1st box in Location will be automatically set according to the assigned Sample Type number Attention Preregistration assigning of Sample Types in Config is recommended It is much simpler to manage the Location values from the vast amoun
6. Connect Barcode Printer to your computer via LAN cable Cross Cable B Connect Barcode Scanner to Computer via USB port C Power On Barcode Printer D Power On Computer E Set IP Address and Gateway 4 Attention Computer is not included in the package All Rights Reserved www MD Best com SBMS 2 0 User Manual H2 MicroDigital Co Ltd 2 IP Address and Gateway Setup for Windows XP Explore Search for Computers Right click on My Network Places from your desktop Map Network Drive Disconnect Network Drive 2 Click Properties to open the Network Connections window Create Shortcut Delete Rename Properties E Network Connections E Ox File Edit View Favorites Tools Advanced Help pak EY D a Ky Back cs Bj A Search Folders Address W Network Connections ik LAN or High Speed Internet Network Tasks Create a new connection Set up a home or small office network Change Windows Firewall settings 8 Disable this network Bridge Connections device x Repair this connection Create Shortcut Rename Repair mil Rename this connection amp View status of this connection change settings of this connection 3 Right click Local Area Connection 4 Click Properties to open the Local Area Connection Properties window 5 All Rights Reserved www MD Best com SBMS 2 0 User Manual t Local Area Connection Prope
7. Name Driver Click Add button to open Create New Data Source window An ODBC User data source stores information about how to connect to Ep the indicated data provider A User data source is only visible to you and can only be used on the current machine ann 5 as Ic reate New Data Source Select a driver for which you want to set up a data source Nunes 5 sk Name Select Microsoft Access Driver mdb ea Na Manna Driver para o Microsoft Visual FoxPro Microsoft Access Driver mdb from the list Microsoft Access Treiber mdb Microsoft dBase Driver dbf Nr Microsoft dBase VFP Driver dbf 3 Click Finish to proceed to Maa p m Imm ODBC Microsoft Access Setup window ODBC Microsoft Access Setup EA Data Source Name ISBMS2 0 Description Cancel Database Database Help e System Database i E or t Click Select to open Select Database None Database Windows System Database 4 Type SBMS2 0 for Data Source Name Advanced 16 All Rights Reserved www MD Best com SBMS 2 0 User Manual ODBC Microsoft Access Setup Select Database Database Name DB SEMS mdb DB SEMS mdb List Files of Type Access Databases m Directories csbms2 O database fee cs gt SEMS20 DATABASE Select DB SBMS mdb file in DATABASE Folder in SBMS2 0 F
8. 1 01 CPH DO 1 1 1 a1104 park 1ml 548133164971 2011 01 CRA DA 3 1 1 231DP kim imi 123452102893 2011 01 CRA DA 12 1 12 10R Lee iml 123456123456 Click Export from Main Menu to transfer the databases in the Archive to Microsoft Excel Spreadsheet 2 Confirm the data transferred to the Spreadsheet In the Pulling Record window clicking Export to Excel will open the Microsoft Excel with the pulling records In addition there is also a function to export corresponding databases to Excel Spreadsheet in Main Frame e Clicking Export will also automatically be saved as Sample Information Current Date Time xls in SBMS2 0 EXCEL folder 21 All Rights Reserved www MD Best com SBMS 2 0 User Manual U2 MicroDigital Co Ltd 8 Configuration Contiguration Sample Name Management Sample Mo Sample Type II gt ga mr mm Shonen Number Sample type SSCS Delete Diagnosis Name ill gt Ber DiasnosisName PSY Delete Adi Information Adi info 1 ADI INF 1 Adi info 4 ADI INFO 4 Adi info 2 AD INFO 2 Adi info 5 ADI INFO 5 Adi info 3 AD INFO 3 Account Management Current ID New ID Activate Current PAW Hew Pr Click Config from Main Menu to open Configuration window Assigning Sample Types Fill in Sample Type category with a title for the sample type 2 Puta number to represent the sample type in Shorten Nu
9. MS 2 0 User Manual U2 MicroDigital Co Ltd SEMS ver2 0 Sample Banking Management Software x m x SBMS SampleBank ng Management Software A Installation of SBMS ENG ver2 0 Sample Banking EER This will install SBMS ENG ver2 0 Sample Banking Management Software on your computer It is recommended that you exit all other programs before proceed with installation Click lt Next gt t ti installation r N m aO Er 3 Click Next to proceed en Dan Attention It is recommended to exit all other programs before the installation a Installation of SBMS ENG ver2 0 Sample Banking SBMS ENG were 0 Sample Banking Management Software will be installed to following folder Click lt Install gt to begin installation to following folder To install to a different folder Either enter install path Or click lt Browse gt and select another folder 4 Set directories for Install folder space needed 1 613K Bytes a Yi Click Install to proceed the installation _ Browse Attention Default Install folder is C SBMS2 0 Installing SBMS ENG were 0 Sample Banking Management Software Click Aborts to abort installation Installing ta CaWSsBhl Sse 0 Installing item System updates Progress Microdigital Co Ltd 10 All Rights Reserved www MD Best com SBMS 2 0 User Manual H2 MicroDigital Co Ltd 8 Installation of SBMS ENG ver2 0
10. Sample Banking Management System for iSBS SBMS 2 0 Installation amp User Manual Version 2 1 MicroDigital Co Ltd A 101 Korea Bio Park B D 694 1 SamPyung Dong D BunDang Gu SungNam Si GyungGi Do 463 400 Korea Tel 82 31 628 2200 Fax 82 31 628 2222 an info md best com www MD Best com microdigital SBMS 2 0 User Manual M2 MicroDigital Co Ltd All Rights Reserved www MD Best com SBMS 2 0 User Manual H2 MicroDigital Co Ltd Table of Contents 1 Hardware Preparation amp 1 Hardware Package 4 IP Address Gateway Setup 2 IP Address and Gateway Setup 5 for Windows XP 3 IP Address and Gateway Setup 7 for Windows 7 2 SBMS Software Installation amp 1 Installation ODBC Setup 2 ODBC Setup for Windows XP 3 ODBC Setup for Windows 7 3 SBMS Software Setting amp Run 1 Run Program 3 Master Window Main Menu 4 Registration 7 Export to Excel 8 Configuration Attention Contents of SBMS can be modified without prior notification for performance upgrades All Rights Reserved www MD Best com SBMS 2 0 User Manual M2 MicroDigital Co Ltd 1 Hardware Preparation and IP Address Gateway Setup 1 Hardware Package 1 1 ISBS Package iSBS MD Si2 Label System VacTube amp VacTube Box 1 2 Hardware Setup ISBS MD Si2 CAUTION The computer and the label printer Must be connected with Cross LAN Cable which is included in iSBS Package Label Printer Scanner A
11. i Adi Adi Adi Adi ent After the amendment click Save to save info info the current information in the Database and info info click Print Barcode to print the barcode for info the modified sample information Users may cancel the modification by clicking Cancel before save CAUTION Users CANNOT print out the barcode without executing save first 20 All Rights Reserved www MD Best com SBMS 2 0 User Manual 12 MicroDigital Co Ltd 3 Deletion of Sample Databases Users can delete Sample Databases by right clicking the Database in the Archive and click Delete Sample Info to open a warning window Click Yes to delete the Sample Databases permanently CAUTION When the sample databases are deleted users CANNOT restore the databases 4 Registration SSeS SES Fill in each categories with information of Barcode Input Search Manual Ine the sample korea wil il Users can register Sample Databases by Age 33 123354 123456 P 1D ones Sex aoa clicking on Registration from Main Menu Diagnosis Name to open Prescription Registration window Prescription Dept DA Prescription Dr Users can put information of the sample in m 2 12 121 1 Help four digi it 5 ogi i 5 fy Se o te ake SEN Prescription Registration window Total sample volume ini Remark Test Categories with is required to fill in
12. l Rights Reserved Click Pulling from Main Menu to open Pulling Record window Scan the 2 D barcode attached on the VacTube Click Search to bring out the information of the sample In case the user is not able to scan the barcode on the VacTube user can either manually type in the location code written on the barcode label and click Search or select the Database among Sample Databases in the Archive then right click and select Pulling to open Pulling Record manually 25 www MD Best com SBMS 2 0 User Manual By Pulling Record Barcode Search Location Search Pulling Record No of sample fi Requested by kin Sample Information Total No 5 Total Vol in Ho Remain M Prescription Dept DR Name kim Prescription Dr Prescription Information Patient ID fma Location Remote Request 12112 ee Lee 12 1 12 1234 1 IN 2011 01 04 1 Pulling Date No of Pulling Requested by 2011 01 04 1 kim AN Mok enough remain sample By Pulling Record Barcode Search Location Search Pulling Record No of sample fi Requested by kim Sample Information Total No E Total Yol in No Remain fa Prescription Information Patient ID Ina Prescription Dept DR Name kim Prescription Dr Age fiz Location Remote Request Lee 12 1 12 1234 1 IN Pulling Date No of Pull Delete All Rights Reserved 4 Filli
13. ll be automatically appear Do NOT change Set Default gateway to 192 168 0 113 and click OK to save and close Attention The IP address MUST NOT be same as the IP address set in the Label Printer however Default gateway MUST be same as the Default gateway in the Label Printer www MD Best com SBMS 2 0 User Manual H2 MicroDigital Co Ltd 3 IP Address and Gateway Setup for Windows 7 Open D Right click on Network from your desktop Map network drive Click Properties to open up the Disconnect network drive Network window Create shortcut omi Delete Recycle Bin View your basic network information and set up connections 7 allel See full LY ee Mi i d ee full map i TOMBLACK PC Multiple networks Internet This computer View your active networks Connect or disconnect Access type Internet Home roup Joined Connections i Local Area Connection 2 I Unidentified network Access type Mo Internet access re Public network Connections i Local Area Connection Change your networking settings are Set up a new connection or network Set up a wireless broadband dial up ad hoc or VPN connection or set up a router or access point Connect to a network 3 Click Local Area Connection on the right side of Unknown network to open Local Area Connection Status window Caution Make sure the label printer is connected to
14. mber category 3 Click Add to assign a sample type Assigning Diagnosis Names 1 Fill in Diagnosis Name category with a title for the diagnosis 2 Click Add to assign a diagnosis name 28 All Rights Reserved www MD Best com SBMS 2 0 User Manual U2 MicroDigital Co Ltd Contiguration Sample Name Management Sample No sample Type saw w a mmm Shorten Number I Sample Type add Delete Diagnosis Name Management Diagnosis Name K3 Mm Diagnosis Name Add Delete Adi info 1 ADT INFO 1 Adi info 4 ADT INFO 4 Adi info 2 JADI INFO 2 Adi info 5 JADI INFO 5 Adi info 3 ADI INFO 3 account Management Current ID Hew ID Current PAW Hew Pr Setup Additional Information Fill in any Adi info under Adi Information with a title for the additional information 2 Click Save to assign an additional category Create or change current ID and Password WD Type current ID in Current ID and current Password in Current P W under Account Management 2 Fillin New ID and New P W 3 Click Activate If there is no current ID or P W leave Current ID or Current P W category blank New ID and Password will be effective on next login A Saved information will be effective from the next Login For setting no ID or Password leave New ID or OO Ko o New P W catego
15. mdb CX icc pkicert Program Files Read Only WINDOWS Exclusive List Files of Type Access Databases m v Network ODBC Microsoft Access Setup Data Source Name SBMS Description Cancel Database Database C SBMS DATABASESDB_SBMS mdb Help i i Repair Compact i Select Create Advanced System Database None C Database Options All Rights Reserved H2 MicroDigital Co Ltd Type SBMS in Data Source Name Click Select to open Select Database window Select DB_SBMS mdb file in DATABASE folder in SBMS2 0 folder Click OK to return to ODBC Microsoft Access Setup window Confirm that DB_SBMS mdb file is selected and click Ok to return to ODBC Date Source Administrator window 13 www MD Best com SBMS 2 0 User Manual 12 MicroDigital Co Ltd ODBC Data Source Administrator UserDSN System DSN File DSN Drivers Tracing Connection Pooling About System Data Sources dd AL ad Haa Confirm SBMS on the list and click Ok Configure to complete the ODBC setup 4n ODBC System data source stores information about how to connect to the indicated data provider A System data source is visible to all users on this machine including NT services 14 All Rights Reserved www MD Best com SBMS 2 0 User Manual U2 MicroDigital Co
16. n the categories under 12 MicroDigital Co Ltd Pulling Record Users can always check the pulling records of samples in Pulling Record window In order to amend or delete pulling records in Pulling Record window right click on the records at the bottom and select Delete Sample Info or Amendment of Sample Info When the user select Delete Sample Info a confirmation window will be shown Click Export to Excel to export the Temporary Records Of Pulling to Microsoft Excel Spreadsheet Select Yes to delete the selected pulling records permanently www MD Best com SBMS 2 0 User Manual 12 MicroDigital Co Ltd 1 Sample_ NcPatient_lFatient_hLocat ion Fulling_LNo_of_FulFulling_Reqguester Kim 12 1 12 12011 01 C7 Lee e Clicking Export to Excel will automatically be saved as Pulling Record Pulling Date xls in SBMS2 0 EXCEL folder Prescription Dept Prescription Dr Pulling Record Total No sf Sam kim 7 Lee When segment pulling is executed Pulling Record values in Sample Databases change from N to Y 7 Export to Excel a le Sample_No Registrat Sample Ty Diagnosis No RemairLocation PrescriptPrescriptPul ling FTotal No Total_Sanr Remark Comment Personal ID 2011 01 CPH DO 1 1 1 a11D4 kim N 1ml 927291271928 2011 01 CPH 00 1 1 1 a1104 kim N imi 548133291021 2011 01 CPH DO 1 1 1 a11DA park Im 548131164221 201
17. ng About System Data Sources _Name Driver S O Add Remove Configure An ODBC System data source stores information about how to connect to the indicated data provider A System data source is visible to all users on this machine including NT services cancel A Click Start gt Control gt Management Tools gt ODBC to open ODBC Data Source Administrator window 2 Click System DSN tab to open 3 Click Add to open Create New Data Source window Create New Data Source Select a driver for which you want to set up a data source Driver da Microsoft para arquivos texto test csv 4 Driver do Microsoft Access mdb Driver do Microsoft dBase dbf Driver do Microsoft E xcelf xls Driver do Microsoft Paradox db Driver para o Microsoft Visual FoxPro Microsoft Access Driver mdb Microsoft Access reib 2 Microsoft dBase Driver dbf kdi E AD man 5700 Miri AKA lt 4 Select Microsoft Access Driver mdb and click Finish 12 to open ODBC Microsoft Access Setup window All Rights Reserved www MD Best com SBMS 2 0 User Manual ODBC Microsoft Access Setup Data Source Name SBMS Description Cancel Database Database Help Create Repair Compact Advanced System Database e None Database Options Select Database Database Name Directories
18. older Default Location C SBMS2 0 DATABASE Close all the windows by clicking OK All Rights Reserved 12 MicroDigital Co Ltd 1 www MD Best com SBMS 2 0 User Manual H2 MicroDigital Co Ltd 3 SBMS Software Setting amp Run 1 Run Program Double clicking SBMS2 0 icon will run the SBMS software Attention For Windows 7 or VISTA users Right click on SBMS2 0 icon ll Click Properties to open Properties window for SBMS 2 0 application Ill Click Compatibility to go to Compatibility tab IV Click and check Run this program as an administrator under Privilege Level Section 2 Login 3 628902 UU 3 62 lt I I pull e Maricrooicita m A AA steer User ID Password Product No First time Login requires User ID and Product No If you do not have them contact the distributor or manufacturer Password is NOT required for the first time You will set the User ID and Password in the Config of SBMS program 18 All Rights Reserved www MD Best com SBMS 2 0 User Manual M2 MicroDigital Co Ltd 3 Master Window Main Frame Sample Databases SBMS Ver 2 0 0 9 De E Search KIA Grating al Tpm Config EPERE EIIE EE TOE IOS se TOE Archive e Registration is to register Sample Databases to the Archive Search is to find Sample Database
19. rties General Authentication Advanced Connect using BS AMD PONET Family PCI Ethernet Ad Configure This connection uses the following items v IS Client for Microsoft Networks Ld m File and Printer Sharing for Microsoft Metworks Install Description Transmission Control Protocol nternet Protocol The default wide area network protocol that provides communication across diverse Interconnected networks Show icon in notification area when connected Notify me when this connection has limited or no connectivity OK Cancel Internet Protocol TCP IP Properties General You can get IP settings assigned automatically if your network supports this capability Utherwise you need to ask your network administrator for the appropriate IP settings Obtain an IP address automatically Use the following IP address IP address 132 163 0 115 Subnet mask 255 285 255 0 Default gateway 192 168 0 114 ba a aL ime I ba I Ukan DNS server address autamaheallu Use the following DNS server addresses aa SY Preferred ONS server Alternate DNS server E All Rights Reserved Properties 12 MicroDigital Co Ltd Click Internet Protocol TCP IP Click Properties to open Internet Protocol TCP IP Properties Window Click and select Use the following IP address Set IP address to 192 168 0 115 Subnet mask values wi
20. ry blank 29 All Rights Reserved www MD Best com SBMS 2 0 User Manual 2 MicroDigital Co Ltd All Rights Reserved www MD Best com SBMS 2 0 User Manual 2 MicroDigital Co Ltd All Rights Reserved www MD Best com microdigital MicroDigital Co Ltd A 101 Korea Bio Park B D 694 1 SamPyung Dong BunDang Gu SungNam Si GyungGi Do 463 400 Korea Tel 82 31 628 2200 Fax 82 31 628 2222 info md best com www MD Best com
21. s based on user s search condition e Pulling is to update the record of the samples when users pull the samples Export is to export the list of Sample Databases in the Archive to Microsoft Excel e Config is to administrate the Archive Only 100 most recently registered Sample Databases are shown in the Archive Users may select multiple number of Sample Databases by pressing Ctrl and select the Databases in the Archive 19 All Rights Reserved www MD Best com SBMS 2 0 User Manual H2 MicroDigital Co Ltd Show Whole Samples Show Selected Samples Users can organize the list in the Archive by showing only selected Sample Databases in the Archive by selecting the Sample Databases right clicking on the selected Sample Databases and clicking on Show Selected Samples To return to the whole list of the Sample Databases in the Archive right click on the Archive and select Show Whole Samples Amendment of Sample Info Amend Pati Name Age Sex Remo Samp Diag ment of Sample Info 2 Amendment of Sample Databases ent ID nal name 112 1234561 234567 Personal ID e Users can modify or correct the information te le Type in Sample Databases by right clicking the nosis Name Total No of Samples Total Sample Sample Database in the Archive and click No Pres Pres Remain cription Dept Amendment of Sample Info cription Dr Location Remark Comm Ad
22. t of Sample Databases in this way Helptabout location Click Help to read the description for each box for Box 1 Location Specify the type of samples ex 1 gt serum 2 gt plasma Values from 1st box defines the type of samples Bonae Type the deep freezer ID ex I gt freezer 1 Values from 2 4 box defines the type of ae OX S ify the ti f the box Inside the d f deep freezer Deep freezer ID EDIS Man naa Ge MA Box 4 Values from 3 4 box defines the location of VacTube Type the Vactube Box ID ex aall aa02 etc Box inside the deep freezer Box 5 Values from 4 box defines VacTube Box ID Rest ei amp einega Ne anena Values from 5 box defines the location of the sample inside the VacTube Box 22 All Rights Reserved www MD Best com SBMS 2 0 User Manual 12 MicroDigital Co Ltd If the user sets Location values identical to A Same location with existing sample Check it and type again other sample which has already been registered an error occurs In this case click OK to continue the registration process Attention Errors occur if users do not fill in mandatory categories with Please make sure to fill in mandatory categories with before save Mandatory categories are Patient ID Sample Type Location Total No of segments and Total sample volume 2 Prescription Registra
23. the computer via LAN Cable Attention If Unidentified network cannot be found please check the hardware connection 7 between the Label Printer and Computer All Rights Reserved www MD Best com SBMS 2 0 User Manual Local Area Connection Status General Connection IPy4 Connectivity IPye Connectivity Media State Duration Speed Bytes Mo Internet access Mo Internet access Enabled OO 12 1 0 Gbps Received 3 228 Local Area Connection Properties Networking Connect using EP Intel R PROYTO00 MT Network Connection This connection uses the following items OM Client for Microsoft Networks Ja 005 Packet Scheduler jm File and Printer Sharing for Microsoft Metworks Intemet Protocol Version 4 TCP IPv4 a Link Layer Topology Discovers Mapper IO Driver wi Link Layer Topology Discovers Responder Install Uninstall Properties Description Transmission Control Protocol Intemet Protocol The default Wide area network protocol that provides communication across diverse interconnected networks All Rights Reserved M2 MicroDigital Co Ltd Click Properties in the Local Area Connection Status window Click and uncheck Internet Protocol Version 6 TCP IPv6 on the list and make sure Internet Protocol Version 4 TCP IPv4 is checked Select Internet Protocol Version 4 TCP IPv4 Click Properties to open Internet Protocol
24. tion Barcode Input Search Manual Input Patient ID ETE For Adi Info users can add their own 33 123354 123456 SON 210 categories by registering categories in Config Sample Type R Diagnosis Name NA Prescription Dept DA Prescription Dr Lee W n 2 Click Save to save current information Location m 2 2 121 fit He p four digits Total No of segments JP ET Click Print Barcode to print 2D barcode Remark ee Comment fest from Label Printer 4 Attach the printed label to Confirm the registered sample database displayed on the uppermost row in the Archive 23 All Rights Reserved www MD Best com SBMS 2 0 User Manual 24 5 Search Prescription Search In Detail search Condition Patient ID Name Age TEX Remote sample Type Diagnosis Name Prescription Dept Prescription Dr Location include Date aa ex 2010 01 01 year month date Renmark Do not use Personal ID Adi info 1 Adi into Adi info Info Info 4 12 MicroDigital Co Ltd Click Search from Main Menu to open Prescription Search In Detail window Fill in the categories which will be the condition to search Click Search to find matched sample databases based on the categories that are filled in Confirm the matched sample databases In order to return to whole list of samples

Download Pdf Manuals

image

Related Search

Related Contents

Terraillon Aquaspa  NuTone 62BK244CBK(X) User's Manual  Here it is - Stonelinks  「イ ンスリンペン型注入器等と注入用針の組み合わせ使用に係る 「使用上  国分寺市立小・中学校プール水の放射性物質濃度測定事業実施マニュアル  Déboucheur revolver  Capitolato tecnico [file]  OWNER`S MANUAL MANUEL D`UTILISATEUR MANUAL  Hoover HGM 61 X  ADVANCE FREIGHT: ALCOHOLIC BEVERAGES: AUDIO VISUAL  