         Contents
1.    teindre le disjoncteur avant de le d  brancher ou  d  connecter l unit      partir des lignes de services     Page 10    EV40 User s Manual    For Hollow Wall Construction    e Place the unit such that both mounting holes can take advantage of solid structural framing  of the outside wall or a strong wall surface  such as plywood     e Size 1 4 20 lag screws are recommended for mounting the EV40 to a wooden structure   Pre drill approximately sized pilot holes to allow the lag screws to grip the wooden  structure while preventing the wood from cracking or splintering while the screw is  fastened     e The included plastic angle washers can be oriented to allow the lag screws to be fastened at  an angle while still providing a solid flat backing to the screw head     e If the the screw head is smaller than the 3 8    washer aperture  an additional flat washer will  need to be placed between the plastic angle washer and the head of the lag screw     e If either mounting hole does not have a solid mounting structure  such as a drywall without  a solid backing  it will be necessary to use proper anchoring hardware such as drywall  toggles or molly bolts     Figure 5  Mounting the EV40 to a hollow wall      Nate Diagonal Mount  Washer is marked with  an  07 dape    Diagonal Perpendicular    Screw Mount Screw Mount             FE       Longer      M  U  IN       N    N                Page 11    EV40 User s Manual    For Solid Wall Construction    e To secure the unit in concrete
2.   pre drill appropriately sized holes and use multi set or  wedge anchor hardware at both mounting points     e To secure the unit in brick or stone  pre drill appropriately sized holes and use sleeve  anchors at both mounting points     The included plastic angle washers can be oriented to allow bolts to be fastened at an angle  or perpendicular to the mounting surface  Note there are two different sets of plastic angle  washers included  Select those washers that best accommodate the mounting hardware     angle of attack    and orient them accordingly     If the head of the mounting hardware is smaller than the 3 8    plastic angle washer aperture   an additional flat washer will need to be placed between the plastic angle washer and the  head of the mounting hardware     Machine screws size 1 4 20 hardware is recommended for mounting the EV40  Screw  shafts of at least 2    are recommended  The EV40 plastic angle washer hole size is 3 8    in  diameter  so ensure that the screw heads are of a larger diameter  Place appropriately sized  washers between the screw heads and the EV40 enclosure mounting flanges     Figure 6  Mounting the EV40 to a solid wall        A      hie     Note Diagonal Mot  Wade fe marked with   o an  O  shape    ig  N COUNTRY     Diagonal Perpendicular   Seren Mount   Screw Moum  17     ic  x   ik    LS    U          Page 12    EV40 User s Manual    Mounting the SAE J1772    Connector Holster    The SAE J1772    connector holster is an available option
3.   transformer manufacturer   s literature to be sure the single leg can supply the required  power     Attention  Avec la connexion en triangle  une borne doit   tre centre tapped  et  seulement les deux phases d   un c  t   ou du l   autre de centre tap peut   tre utilis  e  Les  deux phases doivent mesure 120V    Neutre  La troisi  me ligne  L3  du delta est  208 V  par rapport    la position Neutre  et il est parfois d  signe comme un  stinger    Ne pas utiliser ce troisi  me ligne  Consultez la documentation du transformateur  fabricant pour   tre s  r de bome unique peut fournir la puissance requise     EV40 User s Manual    Caution  A 3 phase delta connected transformer secondary without a center tap on   A one leg cannot be used the the EV40  No    neutral    point is available to be connected  to ground for ground fault protection  The EV40 Charger will not allow the contactor  to close if it does not sense the presence of a ground wire connected to a    neutral     point on the transformer secondary     Attention  Un triphas   triangle connecte transformateur secondaire sans centre tap  sur le terminal ne peut pas   tre utilis   avec la EV40  Aucun point  neutre  est  disponible pour   tre Mise    la terre pour protection de d  faut    la terre  Le EV40 ne  permettra pas le contacteur de fermer si elle ne d  tecte pas la pr  sence d un fil de  masse connect      un point    neutre    sur le secondaire du transformateur     MOUNTING PROCEDURES    Locate the wall mount
4.  3 phase  delta connected  With center tap on one leg  must use  only the two phases on either side of the center tap  The two phases must    both measure 120V AC to ground  Do not use the third leg  208V     stinger         EV40 and EV40P LI  L2  and Safety Ground use 8AWG  75  C copper  wire     185V AC to 264V AC  60 Hz   Circuit Maximum Output  EV40 Model Breaker Current Power  EV40 Hardwired 40A 30A 7 2KW  EV40P 14 50 plug 50A 30A 72KW    Not that the maximum current for the vehicle is set by the duty cycle of  the Pilot waveform     Output power is variable depending on the EV40 model and vehicle  demand     Attached NEMA 14 50P plugs is available on the EV40P    Height 500 mm  19 7 in   Width 225 mm  8 9 in   Depth 135 mm  5 3 in     6 0kg  131bs   25 feet    Operating Temperatures   30  C to  50  C   22  F to  122  F   Storage Temperatures   40  C to  80  C   40  F to  176  F   Enclosure Rating  NEMA 4   watertight    ETL listed  FCC Part Class B    EV40 User s Manual    WARRANTY INFORMATION    LIMITED WARRANTY     ELECTRIC VEHICLE SUPPLY EQUIPMENT  MODEL  EV40  Sun Country Highway Ltd   306 Saskatchewan Crescent  Saskatoon  SK S7N 0K6  1 866 467 1371    Sun Country Highway shall provide the following warranty with respect to the Products to  Representative  its Sub Representatives and their customers     Product 3 year parts  3 year factory labor     Sun Country Highway  Inc  warrants this product to be free from defects in material and  workmanship  The warrantee pe
5.  Figure 2  220 240V Single Phase Figure 3  208V 3 Phase  Wye Connected    7 L1 L3  NOT USED   120V   j                              gt    gt      NEUTRAL 240V     1  NOT USED    gt    gt  120V  LU P  L2  GND    GND       Note  With a wye connected secondary  any two of the legs can be used to provide  208V to the EV40 Charger  For example  L1  amp  L2  or L1  amp  L3  or L2  amp  L3  Leave  the unused leg open  Do not connect it to a Neutral bar  or to Ground  Be sure the  center point is grounded to earth somewhere in the system     Remarque  Avec un transformateur   toile connect   secondaire  deux des jambes  lignes peut   tre utilis   pour fournir 208V a la EV40  Par exemple  L1  amp  L2  ou LI  amp   L3  L2  amp  L3  Laisser la borne inutilis  e ouverte  Ne le connectez pas    un bar Neutre   ou    la terre  Assurez vous que le point central est mis    la terre quelque part dans le  syst  me     Page 8    EV40 User s Manual    Figure 4  240V 3 Phase  Delta Connected  with center tap on one leg     Page 9    C L3  NOT USED        4               esse    L1          120V    NEUTRAL   NOT USED  240V    120V          L2    GND          Caution  With the delta connection  one leg must be center tapped  and only the two  phases on either side of the center tap can be used  The two phases must both measure  120V to neutral  The third line  L3  of the delta is 208V  with respect to neutral  and is  sometimes referred to as a    stinger     Do not use this third line  Consult the
6.  a compact wall or pedestal mounted charging  station that provides the Plug in Hybrid or Battery Electric Vehicle  together Plug in Electric  Vehicles  or    PEV     user with a safe and manageable link between the power grid and the PEV   Both hardwired  EV40  and NEMA plugin equipped  EV40P  versions are available     The EV40 is very easy to use Just unwrap the SAE J1772    charge cable and plug the charge  coupler firmly into the vehicle s charge port     Normally  the vehicle will immediately request a charge using a special communication line in  the cable  Within a few seconds the green    Charging    light on the face of the EV40 will turn on  and the charge cycle will begin  After an average driving day the vehicle battery will require a  few hours to recharge completely  Charging overnight is the most convenient way to maintain  healthy batteries and ensure you vehicle   s full range will be available for the next day     When the vehicle has stopped charging  the green    Charging    light on the EV40 will turn off  To  remove the charge coupler once the charge cycle has competed  or to interrupt a charge in  progress  press and hold down the latch release lever on the charge coupler handle then un plug  the charge coupler from the vehicle charge port     Page 4    EV40 User s Manual    THE EV40 FRONT PANEL    The front panel on the EV40 has four indicator lights     POWER   yellow  indicates that power is  available to the EV40     CHARGING   green   indicates th
7.  breaker panel  before servicing or cleaning the unit     Attention  Couper l alimentation d entr  e    votre station de recharge sur la panneau  de disjoncteurs avant de nettoyer ou de r  parer l appareil     VENTILATION  Some electric vehicles require an external ventilation system to  prevent the accumulation of hazardous or explosive gases when charging indoors   Check the vehicle   s owner   s handbook to determine if your vehicle requires  ventilation during indoor charging     VENTILATION  Certains v  hicules   lectriques n  cessitent un syst  me de ventilation  externe pour   viter l accumulation de gaz explosifs ou dangereux lors de la charge     l int  rieur  Consultez le manuel du propri  taire du v  hicule pour d  terminer si votre  v  hicule n  cessite une ventilation quand le recharge en salle     Note Vehicles which conform to the SAE J1772TM standard for communication with  the charging station can inform the charge station that they require an exhaust fan   The EV40 Charger is not equipped to control ventilation fans  Do not charge the  vehicle with the EV40 if ventilation is required    Remarque  V  hicules qui sont conformes    la norme SAE J1772 TM de  communication peuvent informer la station de recharge qu   ils n  cessitent un  ventilateur d extraction  Le EV40 n est pas   quip   pour contr  ler les ventilateurs  Ne  chargez pas le v  hicule avec le EV40 si la ventilation est n  cessaire     Caution  DO NOT charge your vehicle indoors if it requires ven
8.  to provide a convenient protective  housing for the SAE J1772    connector head when it is not in use     e The SAE J1772    connector holster should be placed so that users have easy and safe  access to the SAE J1772    connector     e For indoor installation  mount the SAE J1772    connector holster between 18 and 48  inches above the ground or grade     e For outdoor installation  mount the SAE J1772    connector holster between 24 and 48  inches above the ground or grade     e The SAE J1772    connector holster has two vertically aligned mourning holes spaced 5 45     apart  one each on the enclosure top and bottom  Use a ruler or template to mark the hole  locations on the mounting surface     e The vertical alignment of the EV40 and SAE J1772    connector holster mounting holes  allows for the convenient mounting of both components onto the same post or wall  structure  For example  the holster may be mounted directly above the EV40     e Place the SAE J1772    connector holster such that both mounting holes take advantage of  solid structural framing inside the wall or a strong wall surface such as plywood     e A set of exterior wood screws and stainless steel washers are included for the purpose of  mounting the SAE J1772    connector holster to a wooden surface     e For mounting to a solid surface such as concrete  brick or stone  alternate hardware may  need to be procured  Examples of solid wall mounting hardware include multi sets  wedge  anchors  and sleeve an
9.  your nearest authorized Service Representative or Sun Country Highway at the above  number  You will receive information as to how service for the product will be provided     If you mail or ship the product in for service  you must insure the product  prepay all shipping  charges  and properly pack it for shipment in its original shipping container or its equivalent  You  are responsible for all loss or damage that may occur in transit     You must provide proof of purchase of the product and the purchase date before any warranty  service can be performed  This limitation applies to damages of any kind including any direct or  indirect damages  lost profits  lost saving or other special  incidental  exemplary or consequential  damages whether for breach of contract  tort or otherwise or whether arising out of the use of or  inability to use the product  even if Sun Country Highway or an authorized Sun Country  Highway representative or dealer has been advised of the possibility of such damages or of any  claim by any other party  Some states do not allow the exclusion or limitation of incidental  damages for some products  so the above limitation or exclusion may not apply to you     This warranty gives you specific legal rights  and you may also have other rights which may vary  from state to state     Page 19    EV40 User s Manual    Page 20    SUN COUNTRY    HIGHWAY    Sun Country Highway  306 Saskatchewan Crescent  Saskatoon  SK S7N OK6  1 866 467 1371  info suncountryh
10. D    SUN COUNTRY    GREENING THE WORLD S HIGHWAYS    Users Manual  EV40    SUN COUNTRY       PLEASE NOTE    This user s manual includes the latest information at the time of printing  Sun Country Highway   Inc  reserves the right to make changes to this product without further notice  Changes or  modifications to this product by other than an authorized service facility could void the product  warranty     If you have questions about the use of this product  contact your customer service representative   Refer to the Customer Support section located in this guide     EV40 User s Manual  Version 01 May  2014  Copyright    2014  Sun Country Highway  Ltd   AII rights reserved     CONTENTS    IMPORTANT SAFETY INSTRUCTIONS  ADDITIONAL SAFETY INFORMATION  FCC INFORMATION    OPERATION    EV40 FRONT PANEL    INSTALLATION  Service Connections  Mounting Procedures  Wiring Instructions  Grounding Instructions    MOVING  amp  STORAGE INSTRUCTIONS  MAINTENANCE   CUSTOMER SUPPORT  SPECIFICATIONS    WARRANTY INFORMATION    10  14  15    15    16    16    Le    18    EV40 User s Manual    IMPORTANT SAFETY INSTRUCTIONS    Carefully read these instructions and the charging instructions in your vehicle owner   s handbook  before charging your electric vehicle     The following symbols may be found in your handbook or on labels affixed to your conductive  charge station     Note This means pay particular attention  Notes contain helpful suggestions     Remarque  Cela signifie accorder une attent
11. at the vehicle is    requesting a charge and AC power is currently  applied to the vehicle     POWER FAULT   red   indicates that the EV40  is not wired correctly  The problem can be due to  improper grounding or a missing Earth Ground   The wiring should be examined by a qualified  electrician     CHARGING FAULT   red   indicates that the  EV40 is unable to communicate with the vehicle  correctly  or a safety fault condition has been  detected by the unit     Table 1  Front Panel LED Information    Figure 1  The EV40 Front Panel                   SUN COUNTRY           Power     CHARGING    evCHARGER  EV40                                        Amber Green Red Power Red  Power Charging Fault Charging Fault Condition  LED LED LED Fault LED  off off off off No power to EVSE  Check circuit breaker  ON off off off ja into EV or EV is not ready to  Charging enabled  power is applied to the  ON ON off off vehicle  ON   not      ON off blinking off Improper grounding or ground is not present  ON   not Problem with EV communications   ON ol oe blinking Disconnect and restart   ae EV ground fault trip  Check vehicle  ON off off Blinking sonn  ction  ON off Blinking Blinking Internal EVSE fault  Call for service             Page 5    EV40 User s Manual    INSTALLATION    Service Connections          Page 6    Caution  To reduce the risk of fire  connect only to a circuit provided with the  appropriate maximum branch circuit over current protection in accordance with the  National Elect
12. chors  Use the type of mourning hardware most appropriate for the  supporting structure     Figure 7  Mounting the holster using the exterior wood screws and washers       Page 13    EV40 User s Manual    WIRING INSTRUCTIONS  Hardwired     Route the EV40 conduit to a nearby service panel or junction box  Use the included 1 2    trade  sized watertight fitting and sealing washer to provide a moisture resistant seal with the service  panel or junction box  If necessary  drill a 7 8    diameter hole to accommodate the liquid tight    fitting     Figure 8  Wiring the EV40 in a junction box          Page 14    Note  Before connecting the EV40 service  conductors  please carefully read the section of  the manual titled    Service Connections    on page  6  If you are unsure of the type of power provided  at the service panel  please consult with you local  utility or call your service representative for  assistance     Note  The three EV40 service conductors use  standard 10AWG  75  C copper wire  The  insulation of each conductor is colour coded for  standard 240VAC installation     Green  Ground  Black  Line 1  120VAC to Ground   Red  Line 2  120VAC to Ground     Les trois conducteurs service la EV40 utilisent  multibrins 10AWG  75  C fil de cuivre  L isolation  de chaque conducteur est un cod   couleur pour  une installation standard de 240 VAC     Vert  Mise a la Terre  Noir  Ligne 1  120 VAC    Mise    la terre   Rouge  Ligne 2  120VAC    Mise    la terre     EV40 User s Manua
13. e telle sorte qu il ne sera pas pi  tin    accroch   plus du  ou autrement  endommag   ou de subir la stress     Ce produit ne contient aucune pi  ce r  parable par l utilisateur  Consultez la section Support     la Client  le dans ce manuel pour obtenir des informations de service  N   essayez pas de  r  parer ou d entretenir la station de recharge vous m  me     Ne faites pas fonctionner votre station ou le c  ble de charge si elles sont physiquement  ouverte  fissur    effiloch    ou autrement visiblement endommag     Contactez votre  repr  sentant de service pour service imm  diatement  Consultez la section Support    la  Client  le dans ce manuel pour obtenir des informations sur le repr  sentant du service dans  votre r  gion     Ne pas utiliser dans les garages commerciaux o   un garage commercial est d  fini comme  une installation  ou une partie  utilis   pour la r  paration de v  hicules    combustion interne  dans lequel la zone peut   tre class  e en raison de vapeurs inflammables   tant pr  sent   comme l essence     e Ne posez pas vos doigts dans de l   int  rieur de l   extr  mit   du SAE J1772TM coupleur du  c  ble de recharge     e Ne pas laisser les enfants utiliser cet appareil   Supervision d un adulte est obligatoire  lorsque des enfants sont    proximit   d une station de charge qui est en cours d utilisation      Page 2    EV40 User s Manual    ADDITIONAL SAFETY INFORMATION    Page 3    Warning  Turn off input power to your charge station at the circuit
14. h measure 120V to Neutral  Earth Ground  must be connected to Neutral at only one point  usually at the Service Entry Breaker  Panel     Attention  Les deux phases utilis  es doivent mesure chaque 120V    Neutre  Misse a  la terre doit   tre connect      Neutre en un seul point  g  n  ralement    l   entr  e panneau  de disjoncteurs de service     EV40 User s Manual    Caution  If a 240V 3 phase feed is from a Delta connected secondary  the leg used  must have a center tap  That tap must be Grounded  Only the two phases either side  of the center tapped leg can be used  See Fig  4 below     Attention  Si une alimentation triphas  s 240V provient d un triangle connect    secondaire  la bornes utilis  e doit avoir une centre tap  Que la tap doit   tre Mise    la  Terre  Seuls les deux phases l   une ou de l   autre c  t   du centre tapped brancher peut    tre utilis  s  Voir la Figure  4 ci dessous     Caution  Warranty is void if this unit is wired improperly  ZN Attention  La garantie est annul  e si cette unit   n   est pas correctement c  bl      Warning  Only a qualified electrician should perform the installation  The  installation must be performed in accordance with all local electrical codes and  ordinances     Avertissement  Seul un   lectricien qualifi   doit effectuer l installation  L installation  doit   tre effectu  e conformit      tous les codes   lectriques locaux et des ordonnances     Only 3 wires are connected  but care must be taken that the service transf
15. ighway ca    Page 21    EV40 User s Manual    
16. ing position of the EVSE        e On the hardwired EV40 the three service conductors are shielded by three feet for flexible  conduit  The EV40 must be positioned such that the conduit can reach a nearby service  panel or junction box    e On the plug in EV40P  the NEMA plug head is connected by one foot of cable to the  bottom side of the EV40P  The charger must be positioned such that the plug can safely be  inserted into a wall mounted NEMA socket     e The plug in EV40P is intended for indoor use only  Currently the NEMA 14 50 and 6 50  plugs  and receptacles are not outdoor rated     e Position the bottom of the charge station at a comfortable height and at least 18 inches  above the ground  Ensure that the LEDs on the front panel of the EV40 can clearly be seen  by anyone who will be operating the device     e The EV40 has two vertically aligned mounting holes spaced 17    apart  one each on the  enclosure top and bottom  Use a ruler or template to mark hole locations on the mounting  surface     Warning  For safety  always turn off input power to the charge station at the circuit  breaker panel prior to plugging it in or wiring it to the service lines  Like wise  turn  off the circuit breaker prior to unplugging it or disconnecting the unit from the service  lines     Attention  Pour s  curit    toujours d  sactiver le courant d entr  e de la station de  recharge au niveau de disjoncteurs de panneau avant de brancher ou de cablage a les  lignes de services  Comme sage 
17. ion particuli  re  Les remarques  contiennent des suggestions utiles     CAUTION  This symbol means be careful  You are capable of doing something that      might result in damage to equipment   ATTENTION  Ce symbole signifie   tre prudent  Vous   tes capable de faire quelque  chose qui pourrait causer des dommages    l   quipement     WARNING  This symbol means danger  You are in a situation that could cause    bodily injury  Before you work on any electrical equipment  be aware of the hazards  involved with electrical circuitry and standard practices for preventing accidents     AVERTISSEMENT  Ce symbole signifie danger  Vous   tes dans une situation qui  pourrait causer des blessures corporelles  Avant de travailler sur un   quipement    lectrique    tre conscient des dangers pr  sentes par les circuits   lectriques et les  pratiques courantes de prevention des accidents     Instructions Pertaining to Risk of Fire or Electric Shock  When using the EV40  basic electrical safety precautions should be followed     e Use this charge station to charge electric vehicles equipped with a SAE J1772TM  charge port only  See the vehicle   s owner s handbook to determine if the vehicle is  equipped with a conductive charge port     e Make certain the charge station s SAE J1772TM charge cable is positioned so it will not be  stepped on  tripped over  or otherwise subjected to damage or stress     e There are no user serviceable parts inside  Refer to the Customer Support section in thi
18. l    GROUNDING INSTRUCTIONS    The product must be grounded  If this product should malfunction or break down  grounding  provides a path of least resistance for electrical current to reduce the risk of electrical shock     For the hardwired EV40    The hardwired EV40 is equipped with three service conductors shielded by three feet fo flexible  conduit  This product must be connected to a grounded  metal  permanent wiring system  or an  equipment grounding conductor must be run with the circuit conductors and connected to the  ground lead on the product     For the Plug in EV40P   The plug in EV40P is equipped with a cord having an equipment grounding conductor and  grounding plug  The plug must be plugged into an appropriate outlet that is properly installed  and grounded in accordance with all local codes and ordinances     Warning  Improper connection of the equipment grounding conductor may result in  a risk of electric shock  Check with a qualified electrician if doubt exists as to whether  the product is properly grounded  Do not modify the plug provided with the product    if it will not fit in the outlet  have a proper outlet installed     Attention  Une mauvaise connexion du conducteur de terre peut entrainer un risque  de choc   lectrique  V  rifier avec un   lectricien qualifi   si il existe un doute quant     savoir si le produit est correctement mis    la terre  Ne pas modifier la fiche fournie  avec le produit   si elle n   entre pas dans la prise  faites instal
19. ler une prise ad  quate par  un   lectricien qualifi       MOVING AND STORING    Note that both the hardwired EV40 and the plug in EV40P are intended for fixed installations   For mounting requirements  consult    Mounting Procedures    section of the    Installation  Instructions    in the manual     Always turn off input power to the charge station at the circuit breaker panel prior to hardwiring  an EV40  or to disconnect an EV40 from the service lines  Likewise  always turn off the the  input power to the charge station at the circuit breaker panel before plugging in or unplugging a  EV40P from a NEMA socket     When transporting the charge station  do not lift or carry the entire hit by the SAE J1772     charge cord  Likewise  do not lift or carry the entire unit by the flexible conduit and input  connectors  EV40  or the NEMA plug  EV40P     The Charge station has a non operational storage temperature of  40  C to  80  C   40  F to   176  F     Page 15    EV40 User s Manual    MAINTENANCE    The EV40 Charger requires no periodic maintenance other than occasional cleaning     4s    Warning To reduce the risk of electrical shock or equipment damage  exercise  caution while cleaning the unit and the EV charge connector cable     1  Turn off your charge station at the circuit breaker before cleaning     2  Clean your charge station using a soft cloth lightly moistened with mild detergent  solution  Never use any type of abrasive pad  scouring powder  or flammable solvents  
20. ormer secondary  connection is definitely known  and the 3 wires from the main circuit breaker panel are  connected and labeled correctly  Figures 2  3  and 4 below show the most common service  transformer secondary wiring formats     Notice that L1  L2   amp  Ground are labeled on each diagram  Those transformer outputs  correspond to the same inputs on the EV40 Charger  Also  each of the two 3 phase diagrams  shows an L3 output  which is not used  Do not connect all three phases of a 3 phase secondary  to the EV40 Charger  This is a single phase device     The Neutral at the service panel must be connected to earth ground somewhere in the system on  any of the three connection arrangements  Ground fault protection is not possible unless the  Neutral  center tap on the service transformer  is connected to an earth ground  If no ground is  provided by the electrical service  a grounding stake must be driven into the ground nearby   following local electrical codes  The grounding stake must be connected to the ground bar in the  main breaker panel  and Neutral connected to ground at that point     Warning  Local electrical codes must always be followed when installing the  grounding stake     Avertissement  Les codes   lectriques locaux doivent toujours   tre respect  es lors de  l installation du piquet de mise    la terre     Page 7    EV40 User s Manual    The following diagrams illustrate the three service transformer secondary connections most  common in North America   
21. press and implied warranties for this product including the warranties of  merchantability and fitness for a particular purpose  are hereby disclaimed  Some states do not  allow the exclusion of implied warranties or limitations on how long an implied warranty lasts   so the above limitation may not apply to you     If this product is not as warranted above  your sole and exclusive remedy shall be repair or  replacement as provided above  In no event will Sun Country Highway  any of its authorized  sales and service representatives  or its parent company be liable to customer or any third party  for any damages in excess of the purchase price of the product     Page 18    EV40 User s Manual    This limitation applies to damages of any kind including any direct or indirect damages  lost  profits  lost saving or other special  incidental  exemplary or consequential damages whether for  breach of contract  tort or otherwise or whether arising out of the use of or inability to use the  product  even if Sun Country Highway or an authorized Sun Country Highway representative or  dealer has been advised of the possibility of such damages or of any claim by any other party   Some states do not allow the exclusion or limitation of incidental damages for some products  so  the above limitation or exclusion may not apply to you     This warranty gives you specific legal rights  and you may also have other rights which may vary  from state to state     To obtain warranty service     Call
22. rical Code  ANSI NFPA 70  US  or the Canadian Electric Code  C22 3  NO  280 13  Canada     Attention  Pour r  duire les risques d incendie  de se connecter uniquement    un  circuit fourni avec le appropri   circuit de d  rivation protection maximale contre les  surintensit  s  en conformit   avec le Code National   lectrique  ANSI   NFPA 70  US   ou Code Canadien de l   lectricit    C22 3 NO  280 13  Canada        EV40 Model Circuit Breaker Rating Receptacle Type  HCE Modele Calibre de Disjoneteur Prise Electrque  EV40  Hardwired  40A n a   EV40P  NEMA 14 50 plug  50A NEMA 14 50R    Caution  This is a single phase device  Do not connect all 3   phases of a 3 phase feed     You may use any two phases of a 3  phase wye   connected feed  The center point of the 3 phases  usually used as Neutral  must be  grounded somewhere in the system  A Neutral connection is not required by the EV40  Charger  Only Line 1  Line 2  and Ground are required  as shown in Fig 3     Attention  II s   agit d   un appareil monophas    Ne pas relier tous les 3 phases d un  alimentation triphas  e  Vous pouvez utiliser les deux phases d un triphas   en   toile  transformateur alimentation  Le point central des triphas    g  n  ralement utilis    comme neutre  doit   tre mis    la terre quelque part dans le syst  me  Une connexion  neutre n est pas exig  e par le EV40  Seulement ligne 1  ligne 2  et Mise a la Terre sont  n  cessaires  comme le montre la Figure 3     Caution  The two phases used must eac
23. riod shall commence on the date of installation date  first use    The product installation date must be evidenced and communicated to Sun Country Highway by  way of the warrantee registration card  or its equivalent   The warrantee registration card must be  filled out completely and accurately  and returned to Sun Country Highway within 30 days after  installation  and the product installation date shall be within 6 months after the purchase date  If a  Product installation date is not communicated to Sun Country Highway as described above  the  product purchase date shall serve as the warranty commencement date     If this product is defective in materials or workmanship during the warranty period  Sun Country  Highway will  at its option  repair or replace the product  Repair parts and  or replacement  products may be either new or reconditioned at Sun Country Highway s discretion  This limited  warranty does not cover service or parts to repair damage due to improper installation or use   including but not limited to improper connections with peripherals  external electrical faults   accident  disaster  misuse  abuse or modifications to the product not approved in writing by Sun  Country Highway  Any service repair outside the scope of this limited warranty shall be at  applicable rates and terms then in effect  The warranty covers factory parts and labour only  it  does not cover field service or removal and replacement of the product or any other costs     AII other ex
24. s  manual for service information  Do not attempt to repair or service the charge station    yourself     e Do not operate your charge station or the SAE J1772TM charge cable are physically open   cracked  frayed or otherwise visibly damaged  Contact your Service Representative for    Page 1    EV40 User s Manual    service immediately  Refer to the Customer Support section in this manual for information  on the Service Representative in your area     e Not for use in commercial garages where a COMMERCIAL GARAGE is defined as a  facility  or portion thereof  used for repair of internal combustion vehicles in which the  areaway be classified due to flammable vapours being present  such as from gasoline     e Do not place fingers inside of the coupler end of the SAE J1772TM charge cable     e Do not allow children to operate this device  Adult supervision is mandatory when children  are in proximity to a charge station that is in use     Instructions concernant des risques d  incendie ou de choc   lectrique  Lorsque vous utilisation de la EV40  pr  cautions fondamentale s  curit     lectrique doivent   tre  suivies     e Utilisez cette station de charge pour charger les v  hicules   lectriques   quip  s d un SAE  J1772    port de recharge seulement  Consultez le manuel du propri  taire du v  hicule afin  de d  terminer si le v  hicule est   quip   d un correcte port de recharge      Assurez vous que le SAE J1772TM c  ble de recharge sur la station de recharge est  positionn   d
25. such as alcohol or benzene     Avertissement  Pour r  duire le risque de choc   lectrique ou des dommages    quipement  user de prudence lors du nettoyage de l appareil et le c  ble du connecteur  de charge EV     1  Eteignez la   quipement au disjoncteur avant de le nettoyer     2  Nettoyez votre   quipement    l aide d un chiffon doux l  g  rement humidifi   avec  une solution de d  tergent doux  Ne jamais utiliser de tampon abrasif  de poudre     r  curer ou de solvants inflammables tels que l alcool ou le benz  ne     CUSTOMER SUPPORT    Call your Service Representative at any time  24 hours a day  at the number below  PLEASE  HAVE THE MODEL NUMBER AND SERIAL NUMBER AVAILABLE WHEN YOU  CALL  These can be found on the side of the enclosure  If your call is made after business hours  or on weekends  please leave your name  telephone number  the unit s serial number  and a brief  description of the problem  A Service Representative will call back at the earliest opportunity     Please visit Sun Country Highway   s Website    www suncountryhighway ca    Page 16    EV40 User s Manual    SPECIFICATIONS    Line Input Power   Service Entrance       Voltage  amp  Wiring    Service Conductors    Voltage Range    Frequency    Current  amp  Output Power   at 240VAC     Plugs    Dimensions    Weight  Cable Length    Environment    Agency Approvals    Page 17    240V AC single phase   LI  L2  and Safety Ground  208V AC 3 phase  wye connected   Any 2 phases  and Safety Ground    240V AC
26. tilation  Contact  your Service Representative for information     Attention  NE PAS RECHARGER un v  hicule    l int  rieur si il n  cessite une  ventilation  Contactez votre repr  sentant de service pour plus d informations     EV40 User s Manual    FCC INFORMATION    This device complies with Part 15 of the FCC rules  Operation is subject to the following two  conditions   1  This device may not cause harmful interference  and  2  This device must accept  any interference received  including interference that may cause undesired operation     This product has been designed to protect against Radio Frequency Interference  RFI   However  there are some instances where high powered radio signals or nearby RF producing equipment   such as digital phones  RF communications equipment  etc   could affect operation     If interference to your charge station is suspected  we suggest the following steps be taken before  consulting your Sun Country Highway Sales and Service Representative for assistance     1  Reorient or relocate nearby electrical appliances or equipment during charging   2  Turn off nearby electrical appliances or equipment during charging     Caution Changes or modifications to this product by other than an authorized service    A facility could void FCC compliance     Attention  Modifications apport  es    ce produit par quiconque autre qu un centre de  service autoris   peut annuler la conformit   FCC     OPERATION    The EV40 Electric Vehicle Charging station is
    