Home

- Plasmon

image

Contents

1. S Plasmon The Leader in Professional Data Archival Solutions The Plasmon UDO30D I 5 25 inch Optical Drive User Manual P N 97707301 C PREFACE Copyright Copyright 2006 by Plasmon9 All rights reserved This manual and the information contained herein are the property of Plasmon United States Office European Headquarters UK Plasmon Plasmon Data Limited 4425 ArrowsWest Drive Whiting Way Colorado Springs CO 80907 3489 Melbourn Herts SG8 6EN Disclaimer Plasmon makes no representation or warranties with respect to the contents of this document and specifically disclaims any implied warranties of merchantability or fitness for any particular purpose Furthermore Plasmon reserves the right to revise this publication without obligation of Plasmon to notify any person or organization of such revision or changes Trademark Notices Plasmon is a U S registered trademark of Plasmon All other product names are trademarks or registered trademarks of their respective owners Revision History Revision Date Description A 1 05 Initial release B 7 05 Updated Safety Agency information added TIN Enable to the UDO30I C 6 06 Updated LED indicator information added USB con nectivity for UDO30D added compliant media NOTE The most current information about this product is available on the Plasmon web site www plasmon com Plasmon UDO30D I Drive User Manual Preface Document Revision C Page 1 Conventions Used
2. WARNING A WARNING is used to alert the reader to situations or conditions that could potentially result in personal injury fire hazard or equipment damage WARNUNG Eine WARNUNG ist benutzt den Leser zu Lagen oder Bedingungen zu warnen die m glicherweise in pers nlicher Verletzung Brandrisiko oder Ger tschaden resultieren k nnten CAUTION A CAUTION is used to warn of undesirable procedures or of situations in which equipment damage could result NOTE A NOTE is used to emphasize an area of text or to provide additional information Preface Plasmon UDO30D I Drive User Manual Page 2 Document Revision C Product Warranty Plasmon warrants hardware products against defects in materials and workmanship and that the hardware conforms to Plasmon specifications for one year from date of purchase from Plasmon depending on product type This warranty provides for a no cost repair or replacement of defective hardware upon return of hardware to a Plasmon Repair Depot The decision to repair or replace is solely at the discretion of Plasmon Plasmon reserves the right to use remanufactured parts or products that are equivalent to new in performance as replacements Site registration for warranty may be completed at http www plasmontech com warranty index html The Plasmon warranty is automatically activated 30 days from the date of shipment from the factory unless Plasmon is notified that an earlier commencement is requested Add
3. s internal chassis VO RSICHT KLASSE 2B LASER LEICHT YS B OFFEN NICHT IN DEN STRAHL BLICKEN Complies with IEC 60825 1 1993 A1 1997 A2 2001 Plasmon UDO30D I User Manual Safety Agency Standards Document Revision C Page 29 CDRH Regulations The Center for Devices and Radiological Health CDRH of the U S Food and Drug Administration implemented regulations for laser products on August 2 1976 These regulations apply to laser products manufactured from August 1 1976 Compliance is mandatory for products marketed in the United States Use of controls adjustments or performance of procedures other than those specified in this manual may result in hazardous radiation exposure Power Cord Set Selection The voltage rating and the current rating of the power cord set shall be higher than the rated voltage and current of this unit The voltage of the power cord set shall be higher than the power source For the U S and Canada Power cord must be UL listed and CSA labeled Type SJT SVT ST SJO or SO 3 conductors No 18 AWG rated 125v 10A Safety Agency Standards Plasmon UDO30D I User Manual Page 30 Document Revision C CONTACTING PLASMON Technical Support in the United States Plasmon Technical Support 1 877 585 6793 1 719 593 4192 fax e mail tech support plasmon com Internet www plasmon com Technical Support in Europe Middle East and Africa Plasmon Technical Support 44 0 1763 262 9
4. the dealer or an experienced radio TV technician for help Industry Canadian Notice per ICES 003 English This digital apparatus does not exceed the Class B limits for radio noise emissions from digital apparatus set out in the interference causing equipment standard entitled Digital Apparatus ICES 003 of the Industry Canada French Cet appareil num rique respecte les limites de bruits radio lectriques applicables aux appareils num riques de Classe B prescrites dans la norme sur le mat riel brouilleur Appareils Num riques NMB 003 dict e par l Industrie Canada European Notice C This product is in conformity with the following directive EN 55022 CISPR 22 Class B EN 55024 EN 61000 3 2 EN 61000 3 3 This product is in conformity with the EMC directive and low voltage directive Plasmon UDOS30D I User Manual Safety Agency Standards Document Revision C Page 27 Australia New Zealand This equipment has been tested and complies with AS NZS 3548 Japan CORE PHUBLESERRESAEMAHBRS VCCI ORB HOC VFABMRRMRECST CORB KERR CEAT SCC SANCLTOIETH CORBPIVAPTLEY ar Si RICMELT ASHES SMS FHC TCEPHVET PRBS HE TELUMWYRUELT FSO This is a Class B product based on the standard of the Voluntary Control Council for Interference from Information Technology Equipment VCCI If this is used near a radio or television receiver in a domestic environment it may cause radio interference Install and use the equipment ac
5. 63 44 0 1763 264 444 fax e mail support plasmon co uk Internet www plasmon com Technical Support in Asia Pacific South America and Canada International Calls 1 719 593 4437 1 719 593 4192 fax e mail tech support plasmon com Software and Driver Updates Contact your service provider for the latest firmware and driver updates Before Placing a Service Call to Plasmon Register your site on line at http www plasmontech com warranty index html Placing a Service Call Contact your service provider directly If Plasmon is your service provider please have the following information available when calling Serial number Description of failure System information Computer type and SCSI adapter Software configuration Software and version number Plasmon The Leader in Professional Data Archival Solutions
6. CSI bus requires a unique ID in the range of 0 to 15 for Wide SCSI ID 7 is usually reserved for the host computer The UDOSOD is shipped with SCSI ID 1 0001 set as a default There is a label next to the switches showing how to set IDs This information is also shown in the following table Table 5 UDO30D SCSI ID Switches Switch SCSI ID Bits binary 1 SCSI ID Bit 3 MSB 2 SCSI ID Bit 2 3 SCSI ID Bit 1 4 SCSI ID Bit 0 LSB 5 TIN Enable 6 No Connection Refer to the following table for switch settings Plasmon UDO30D I Drive User Manual Document Revision C Getting Started Page 15 Table 6 Setting UDO30D SCSI IDs SCSI ID Switch 1 Switch 2 Switch 3 Switch 4 0 E E i gt 1 5 On 2 x On 5 3 On On 4 On i 5 g On x On 6 On On 7 On On On 8 On 3 9 On gt a On 10 On On 11 On On On 12 On On s 13 On On On 14 On On On 15 On On On On The host computer must have a SCSI host adapter card such as the Adaptec 29160 equipped with a 68 pin Micro D connector 2 Connect the supplied 68 conductor LVD SCSI cable between the computer and the drive The UDO30D is equipped with two Micro D 68 pin connectors on the rear panel A SCSI bus must be terminated at each end of the line One terminator is required on the last device in the chain The other terminator is usually on the host computer or adapt
7. The UDOSOI can be used in both the vertical and horizontal plane If the vertical position is used the drive should be on its left side with the power connector on top as shown in the figure below In the horizontal position the drive must be top side up Power Connector sed Y hee fri ije coo T E E Eaa ri q PERS E Figure 10 Proper Vertical Orientation for UDO30 5 Connect the drive to the SCSI bus using the supplied 68 conductor flat cable This cable has three keyed connectors and an attached SCSI terminator For correct orientation pin 1 is usually identified by some marking or color on the edge of the cable and by a small arrow on the connectors 6 Attach the enclosure s power connector to the drive The connector is keyed to ensure proper orientation 7 Insert the UDO Resource CD wait for it to auto start and install the UDO software CAUTION Do not insert media into the drive until the software installation is complete Getting Started Plasmon UDO30D I Drive User Manual Page 22 Document Revision C Setting TIN Enable Along with the SCSI ID pins on the Function Connector on the back of the UDOSOI is a pair of pins 9 and 10 which are jumpered to set TIN Enable Turning on TIN Target Initiated Negotiations enables the drive to
8. age the eject screw mechanism About 60 turns ejects the cartridge In Line Power Supply The UDO30D is shipped with an in line power supply and power cord Do not replace the supply with a substitute An authorized replacement is available from Plasmon Please refer to the Accessories and Spare Parts section at the end of this chapter Plasmon UDO30D I Drive User Manual Product Overview Document Revision C Page 9 About the UDO30I The UDO30I is intended for installing in a system enclosure It fits standard 5 25 inch device mounting spaces and provides the appropriate connectivity Function Connector SCSI Connector Power Connector eG e oo oo F 4006 600000000003003 FS E gt Figure 3 UDO30 Back View The DC power connector is an industry standard keyed 4 pin connector Table 2 UDO30 Power Connector Pin Description 1 12V DC 2 8A Peak 100ms Max 0 6A Typ 2 12V DC Return 3 5V DC Return 4 5V DC 2 5A Max 1 9A Typ The SCSI connector is a SCSI 3 standard keyed 68 pin connector The Function connector is used by Plasmon when the drive needs to communicate within a data library Here the first four pairs of pins are used with supplied jumpers to set the SCSI ID for the drive Setting the SCSI ID is covered in the next chapter under Setting Up the UDOGSOI Product Overview P
9. ation power is set at the factory as the default by placing a jumper across the last pin pair pins 23 amp 24 The following table shows how the pin pairs relate to the SCSI ID bits Table 7 UDOS3O0I SCSI ID Pin Pairs Pins SCSI ID Bits binary 182 SCSI ID Bit 3 MSB 3 amp 4 SCSI ID Bit 2 5 amp 6 SCSI ID Bit 1 788 SCSI ID Bit 0 LSB 9810 TIN Enable Refer to the following table for setting the drive SCSI ID Getting Started Plasmon UDO30D I Drive User Manual Page 20 Document Revision C Table 8 Setting UDO30I SCSI IDs SCSI ID Pins 1 amp 2 Pins 3 amp 4 Pins 5 amp 6 Pins 7 amp 8 0 1 Jumper 2 Jumper 3 Jumper Jumper 4 Jumper 5 Jumper Jumper 6 Jumper Jumper 7 Jumper Jumper Jumper 8 Jumper 9 Jumper Jumper 10 Jumper Jumper 11 Jumper Jumper Jumper 12 Jumper Jumper 13 Jumper Jumper Jumper 14 Jumper Jumper Jumper 15 Jumper Jumper Jumper Jumper 4 Mount the drive in the enclosure Attaching screws are supplied with the drive The screws are M3 x 4mm The mounting plate in the enclosure should be within 1 5mm to 2mm thick including the washer CAUTION Mounting plates differ in thickness To avoid damage to the drive only use screws that extend into the drive 1mm to 2mm maximum Plasmon UDO30D I Drive User Manual Document Revision C Getting Started
10. cks of five UDO30WOX5 Plasmon 30GB UDO true Write Once 8 192 Bytes sector 50 year data life sold in packs of five UDO30CWX5 Plasmon 30GB UDO Compliant Write Once 8 192 Bytes sector 50 year data life sold in packs of five Spares SP97707192 UDOSOD in line power supply SP97707191 UDO30D Enclosure without drive SP97707394 UDOSOD Fan Filters 160 101300 00 Plasmon 30GB Drive Cleaning Cartridge 97708057 UDO30D USB 2 0 Kit Product Overview Page 14 Plasmon UDO30D I Drive User Manual Document Revision C Unpacking CHAPTER 2 GETTING STARTED When moving the UDO30D I to an environment where there is a significant difference in temperature or humidity leave the unit in its packaging for at least two hours Find a clean flat soft surface for unpacking For the UDO30I full anti static precautions should be followed while handling Use an anti static mat and ground when handling the internal unit Always hold the internal unit by the frame only and do not touch any electrical components Refer to the enclosed packing list to verify the accessories supplied with the UDO drive Setting Up the UDO30D for SCSI Connection If the drive is connecting to a SCSI interface before applying power follow these steps 1 Set the SCSI ID of the drive via switches on the back of the unit Refer to the section About the UDO30D in the previous chapter to locate the SCSI ID switches Each device on a S
11. cording to the instruction manual Product Safety Standards The Plasmon UDO30D I drives comply with the following domestic and international product safety standards UDOSO0I UL Standard 60950 1 1st Edition 2003 Safety of Information Technology Equipment CSA Standard C22 2 No 60950 1 03 Safety of Information Technology Equipment IEC 60950 1 1st Edition 2001 UDO30D UL Standard 60950 3rd Edition Safety of Information Technology Equipment CSA Standard C22 22 No 60950 00 3rd Edition Safety of Information Technology Equipment IEC 60950 3rd Edition 1999 Safety Agency Standards Plasmon UDO30D I User Manual Page 28 Document Revision C Laser Safety Notice This drive complies with 21 CFR 1010 10 1040 11 and IEC 60825 1 1993 A1 1997 A2 2001 as a Class 1 Laser product WARNING Use of controls or adjustments or performance of procedures other than those specified herein may result in hazardous radiation exposure WARNUNG Gebrauch von Steuerungen oder Regelungen oder Leistung der Verfahren anders als die angegebene hierin kann in gef hrlicher Bestrahlungsaussetzung resultieren CLASS 1 LASER PRODUCT LASER KLASSE 1 PRODUKT Laser Technical Data Type GaN diode laser Wavelength 408 nm 5nm Maximum power 45 mW CW 60 mW pulsed CAUTION e gt i CLASS 3B LASER LIGHT WHEN OPEN Class 1 product label located on the drive s outer enclosure AwIOD EXPO SURE TO THE BEAM Class 3B laser caution label located on drive
12. er card Refer to the documentation supplied with your SCSI card or computer system to check the host termination This is normally enabled 3 If the drive is the last device on the SCSI bus install the supplied terminator in the drive s unused SCSI connector 4 The UDO30D should only be used in the horizontal plane Getting Started Page 16 Plasmon UDO30D I Drive User Manual Document Revision C 5 Connect the in line power supply and power cord to the unit and connect the power cord to an appropriate grounded power source 6 Apply power to the unit before applying power to the host computer 7 Insert the UDO Resource CD wait for it to auto start and install the UDO software If the system does not support auto start open the CD and double click on the autorun exe file CAUTION Do not insert media into the drive until the software installation is complete The UDO30 also operates in SE SCSI mode depending on the other devices connected to the SCSI bus Setting TIN Enable Along with the SCSI ID switches on the back of the UDO30D enclosure is a switch number five for setting TIN Enable Turning on TIN Target Initiated Negotiations enables the drive to negotiate Wide and Synchronous on the SCSI bus The default setting for this switch is off since target devices do not normally initiate negotiation Some platforms drivers or adapter cards may fail to re negotiate correctly under certain conditions In this e
13. grae a aa Slaw aca Gode RO ge br ERG Bode RE 1 Revision History qe eoo ete aras 1 Conventions Used xp eme Yana kee Das Peete ee sbi FIG eed 2 Product WAIT an orcas ld 3 CHAPTER 1 PRODUCT OVERVIEW ausu Edd ba REESE SNEEN S EE eda d d RR 7 General Information llle RR ras 7 isl RR REIS RUTRUM 7 About the UDOBOD cours es ace satan gad ein REVO ID erc e cde Ro Guo Mp AR 8 UDOSOD Air Filters RR RR RRRRRRRRRRRRRRRRRR RR Rc eee ees 9 UDO30D Emergency Eject 0 0 9 In Line Power Supply 0 000 c cee rn 9 About the DOS3Q0l ix pe acera dan dedi Eni RR kA RI ds Bes eed 10 UDO30I Emergency Eject 0 teens 11 DOME as cere ee ge ern le Senso A Sh ee Boe ee et ee See 12 Write Protecting Media 0 cece te te tee 12 Media Care and Handling 2l 13 Software DriVers Ex ol es REO A EE E AE EE 13 Accessories and Spares eco EEE EGO KE RR ERG E ye tees 14 CHAPTER 2 GETTING STARTED cccococcoccccc 15 nere dog C rc RPEPE 15 Setting Up the UDO30D for SCSI Connection 0 0 0 15 Setting TIN Enable 2 2 liliis rr 17 Setting Up the UDO30D for USB Connection ennen ee 18 Setting Up the UDO3OI ess does aka RE oa te e b Sead a eae Ke 20 Setting TIN Enable 2 2 2 0 aci kaa a Rh rh 23 APPENDIX A SPECIFICATIONS ee re er AA AAA 25 Drive Specifications cia aia re Seen BENE Dead als MN et eE 25 SCSI Cable Specifications 2m bande m Ae RR RR ed
14. ing CAUTION Always condition the media to room temperature before loading it into the UDO drive Media cleaning should only be performed by Plasmon trained personnel Improper handling or an inappropriate environment can damage the media To ensure continued reliability When media is loaded into the drive or when handling media ensure that the cartridge case is clean Dirty media cartridges may cause problems If a cartridge case is dirty wipe with a lint free cloth Do not carry media loosely for example in a box or basket Do not load damaged media into a drive Damaged media can interfere with reliability Never touch the disk Opening the cartridge door and touching the disk may interfere with read write reliability Do not expose the media to moisture or direct sunlight Software Drivers The UDO30D I optical drives are supplied with software for the major desktop operating systems When the UDO drive setup is complete insert the provided UDO Drive Resource CD and follow the instructions to install the appropriate software CAUTION Do not insert a media cartridge into the drive until the software installation is complete Plasmon UDO30D I Drive User Manual Product Overview Document Revision C Page 13 Accessories and Spares Table 4 Accessories and Spares List Part Number Description Media UDO30RWX5 Plasmon 30GB UDO Rewritable 8 192 Bytes sector 50 year data life sold in pa
15. is available as a desktop unit in its own enclosure UDO30D and for internal installation within a system enclosure UDOSOI Features The main features of the UDOSOD I are 30GByte 15GB per side storage on rewritable and write once media Half height 5 25 inch form factor 32MByte data cache for write and read operations 28ms typical seek time Up to 40MBytes sec synchronous data rates LVD SCSI SCSI or USB connectivity to a host computer UDO30D only Universal AC supply operates from 100 to 240 volts desktop version Plasmon UDO30D I Drive User Manual Product Overview Document Revision C Page 7 About the UDO30D The UDO30D is the desktop version of the drive This drive ships in its own enclosure which provides the appropriate connectivity Power Power On LED SCSI ID Switches Fan and Air Filter Connector Figure 1 UDO30D Back View The two SCSI connectors are SCSI 3 standard shrouded keyed 68 pin Micro D connectors The SCSI ID switches are used to set the SCSI ID for the drive Setting the SCSI ID is covered in the next chapter under Setting Up the UDO30D LED Active Amber LED Ready Green po n 30 GB O Plasmon UDO Ll MEN Emergency Eject Eject Button Figure 2 UDO30D Front View On the front of the drive there are two LEDs which function as explained in the following table Prod
16. itional coverage may also be purchased Please contact your local Plasmon support representative for more information and service contract details Spare parts are covered by a 180 day warranty Remanufactured parts are covered by a 90 day warranty Warranties for either spare parts or remanufactured parts are from the date of shipment unless the original warranty of the unit is still in force and the remainder of the original warranty exceeds the stated warranty periods above CAUTION Returning the drive in unauthorized packaging may damage the unit and void the warranty If problems with the drive occur contact your maintenance organization do not void the product warranty by allowing untrained or unauthorized personnel to attempt repairs WARNING Untrained personnel operating the drive may create dangerous situations This could lead to physical harm to the operator data loss and or disabling of the drive WARNUNG Ungeschultes Personal das den Antrieb bedient kann gefahrliche Lagen bedingen Dies k nnte zu physischem Schaden des Bedieners Datenverlust oder Antrieb Sperre f hren Plasmon UDO30D I Drive User Manual Preface Document Revision C Page 3 Preface Plasmon UDO30D I Drive User Manual Page 4 Document Revision C TABLE OF CONTENTS cig ee ee ee ee ee ee ee 1 COPY asu cee bee eee or Peek ERROR oe ESPE ler Coheed bee de Rees 1 Diselalmier essa dr a dido eat Se cnet ate Ge wae Sh 1 TrademarkJNOotiCes ouai arcere
17. lasmon UDO30D I Drive User Manual Page 10 Document Revision C LED Active Amber LED Ready Green Old 30 GB i Emergency Eject Plasmon Eject Button Figure 4 UDO30I Front View On the front of the drive there are two LEDs They function as explained in the following table Table 3 UDO30I LED Signals LED Pattern Active Amber Ready Green On Accessing disk Media Ready Power on diagnostic Power on diagnostic Flashing NA Inaccessible disk inserted 0 8 sec cycle Drive Not Ready On Off 1 1 Rapid Flashing NA Loading 0 2 sec cycle spin up On Off 1 1 Slow Flashing Amber Green irregular alternating Drive is in Fail Safe mode variable cycle alternating LEDs Power on diagnostic error Both LEDs On for 1 2 sec and then Off for 1 2 sec Indicates drive failed write power calibration WPC and should be cleaned using the Plasmon lens cleaning cartridge Slow Flashing 1 2 sec On 1 2 sec Off Off Disk not inserted After spin down Power off Drive Not Ready UDO30I Emergency Eject If normal media eject procedures fail to work and it becomes necessary to use the emergency eject mechanism the unit must be powered off Make sure the disk has stopped rotating 20 30 seconds after power off To manually eject the cartridge insert a 2mm flat blade screwdriver into the hole to the left of the no
18. last device on a SCSI bus termination is required USB Cable Specifications Only the special USB to SCSI cable supplied by Plasmon is appropriate for connecting the UDO30D to USB SCSI termination is still required on the drive when connecting to USB on the host computer Specifications Plasmon UDO30D I Drive User Manual Page 26 Document Revision C APPENDIX B SAFETY AGENCY STANDARDS FCC Notice The equipment to which this manual pertains has been tested and found to comply with the limits for a Class B digital device pursuant to part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a residential installation This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with this User s Guide may cause harmful interference to radio communications However there is no guarantee that interference will not occur in a particular installation If this equipment does cause harmful interference to radio or television reception which can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one or more of the following measures Reorient or relocate the receiving antenna Increase the separation between the equipment and the receiver Connect the equipment into a circuit different from that to which the receiver is connected Consult
19. negotiate Wide and Synchronous on the SCSI bus The default setting for TIN Enable is off not jumpered since target devices do not normally initiate negotiation Some platforms drivers or adapter cards may fail to re negotiate correctly under certain conditions In this event the host computer cannot communicate with the drive over the SCSI bus Enabling TIN allows the drive to re negotiate and maintain communication with the host If communication is lost on power cycles or drive resets at host boots setting the TIN Enable switch may solve the problem In general Microsoft systems may need TIN enabled AIX Unix and Linux systems typically need TIN disabled Plasmon UDO30D I Drive User Manual Getting Started Document Revision C Page 23 Getting Started Plasmon UDO30D I Drive User Manual Page 24 Document Revision C APPENDIX A SPECIFICATIONS Drive Specifications These specifications are subject to change without notice Table 9 UDO30D Drive Specifications Rotational Speed WORM RW Specification UDO30D UDO30I Access Times Average Seek 1 3 full stroke 28 ms 28 ms Load Time 5 sec 5 sec Unload Time 3 sec 3 sec 2100 1950 RPM 2100 1950 RPM Data Transfer Rates Number of Media Insertions Max Sustained Read 8 MB s 8 MB s Max Sustained Write amp Verify 4 MB s 4 MB s Burst Asynchronous 3 MB s 3 MB s Burst Synchronous Fast SCSI 40 MB s 40 MB s enabled Buffer Size 32 MB 32 MB MTBF Power On Ho
20. rmal eject button Rotate the screwdriver clockwise while pressing it firmly into the drive to engage the eject screw mechanism About 60 turns ejects the cartridge Product Overview Page 11 Plasmon UDO30D I Drive User Manual Document Revision C UDO Media The Plasmon UDO30D I optical drive uses Plasmon 5 25 inch two sided UDO media cartridges with 30GByte capacity These are available in both true Write Once Rewritable and Compliant Write Once media types Compliant Write Once media provides for selective data destruction for security purposes Figure 5 UDO Media Types UDO media is the same form factor as MO media However UDO media is not compatible with MO drives and MO media is not compatible with UDO drives UDO media is two sided To access side A for example insert the media with the side marked A facing up toward top of drive New UDO media must be formatted before use Refer to the software documentation on the supplied UDO Drive Resource CD Write Protecting Media To write protect one side of the media slide the write protect tab on that side in the direction of the protect arrow as shown in the figure below There is a write protect tab on each side of the disk When a side is protected the write protect window is open Write Protect Tab Write Protect Window Figure 6 Write Protecting UDO Media Product Overview Plasmon UDO30D I Drive User Manual Page 12 Document Revision C Media Care and Handl
21. s oS as ac e d 26 SCSI Cables and Connectors 0 0 0 liliis as 26 SCSI Termination lcceeeeeeeeee RR RR RR Rs 26 USB Cable Specifications x suis ki ERE bees we SEE Sen Sed AA EN E Ed a 26 Plasmon UDOS30D I Drive User Manual Table of Contents Document Revision C Page 5 APPENDIX B SAFETY AGENCY STANDARDS ion ee ARRRARRREYRARARARARREXATRREA 27 POG NOICE uu oo God ba EAN A O a 27 Industry Canadian Notice per ICES 003 20 ennen enke keen kk ker kk 27 European Notice sdear ines cubidewiee inde bac bee police SEE Oed prac cR BONO cee 27 Australia New Zealand 2 2 0 eee eens 28 Japans iiid pce POLE EERE Rr E Eo edo e d EROR DEEL E POEL ESE wed Shane 28 Product Safety Standards ses cscneceee ddan quc aO A UR RR RR RR 28 Nec 28 UDOSOD serere bem ee eee Ben eae Ae Yee a dan wes ae es A beams 28 Laser Safety NOMS corsa e a RES 29 CDRH Regulations s sac cire RO AAA AAA 30 Power Cord Set Selection ux ida accus Ee barda era das 30 CONTACTING PLASMON cc AAA 31 Table of Contents Plasmon UDO30D I User Manual Page 6 Document Revision C CHAPTER 1 PRODUCT OVERVIEW General Information The Plasmon UDO30D 1 is an optical disk drive that reads and writes to 5 25 inch 30GByte UDO Ultra Density Optical media UDO blue laser technology provides a high performance reliable and cost effective long term data storage device The drive handles both true Write Once and Rewritable media types The UDO30
22. uct Overview Plasmon UDO30D I Drive User Manual Page 8 Document Revision C Table 1 UDO30D LED Signals LED Pattern Active Amber Ready Green On Accessing disk Media Ready Power on diagnostic Power on diagnostic Flashing NA Inaccessible disk inserted 0 8 sec cycle Drive Not Ready On Off 1 1 Rapid Flashing NA Loading 0 2 sec cycle spin up On Off 1 1 Slow Flashing Amber Green irregular alternating Drive is in Fail Safe mode variable cycle Power on diagnostic error alternating LEDs Slow Flashing Both LEDs On for 1 2 sec and then Off for 1 2 sec 1 2 sec On 1 2 sec Off Indicates drive failed write power calibration WPC and should be cleaned using the Plasmon lens cleaning cartridge Off Disk not inserted After spin down Power off Drive Not Ready UDO30D Air Filters The UDOSOD is shipped with an air filter installed This air filter is required When the filter is noticeably dirty it must be replaced Additional filters are supplied with the drive UDO30D Emergency Eject If normal media eject procedures fail to work and it becomes necessary to use the emergency eject mechanism the unit must be powered off Make sure the disk has stopped rotating 20 30 seconds after power off To manually eject the cartridge insert a 2mm flat blade screwdriver into the hole to the left of the normal eject button Rotate the screwdriver clockwise while pressing it firmly into the drive to eng
23. urs 100 000 hrs 100 000 hrs 750 000 cycles 750 000 cycles Environmental Operating Temperature Non operating Temperature Operating Humidity Non operating Humidity 10 to 35 C 40 to 60 C 5 to 90 non condensing 5 to 95 non condensing 15 to 45 C 40 to 60 C 5 to 90 non condensing 5 to 95 non condensing Electrical Operating Voltage Power Requirements 100 to 240VAC 50 60Hz 12V 4 2A Max 50W 5V 5 12V 5 5V 2 5A Max 1 9A Typ 12V 2 8A Max 0 6A Typ Structure Dimensions WxHxD in mm Weight Drive Orientation 185 x 65 x 283 2 9 Kg w o power cord amp supply Horizontal 146 x 41 1 x 207 8 1 5 Kg Horizontal Vertical Drive Warranty Plasmon UDO30D Drive User Manual Document Revision C One year parts amp labor return to base One year parts amp labor return to base Specifications Page 25 SCSI Cable Specifications SCSI Cables and Connectors Plasmon recommends using LVD SCSI cables and connectors that conform to SCSI 3 specifications The Plasmon UDO30D is shipped with a shielded two meter LVD SCSI cable with shielded 68 pin Micro D connectors The UDO30I is shipped with an LVD flat SCSI cable with three keyed 68 pin connectors and a terminator attached SCSI Termination The Plasmon UDOSOD is shipped with an LVD HD68 SCSI terminator The UDO30I is shipped with a terminator attached to the flat cable If the drive is the
24. ve 4 After a short time the drive is recognized and shows up as a Removable Disk drive on the host computer 5 The system is ready to use Plasmon UDO30D 1 Drive User Manual Getting Started Document Revision C Page 19 Setting Up the UDO30I When handling the UDO3OI use full anti static precautions as outlined in the Unpacking section To install the drive in an enclosure follow these steps 1 Ensure that the power cable is correctly wired and that power is within the unit s specifications 2 Ensure that adequate ventilation and cooling is provided Plasmon recommends that filtered air is blown from the rear to front of the drive 3 For convenience set the SCSI ID for the drive before installing it in an enclosure Each device on a SCSI bus requires a unique ID in the range of 0 to 15 for Wide SCSI ID 7 is usually reserved for the host computer The UDO30I is shipped with SCSI ID 1 0001 set as a default The SCSI ID is set on the UDO3O0I by placing appropriate jumpers on the first four pairs of pins of the Function Connector located on the back of the drive There is a label on the top of the drive which shows which pin pairs of the Function Connector are used to set the SCSI ID bits The following figure also shows this information SCSI ID bits TIN Termination 3210 Enable Power C Pin 1 X Figure 9 UDO30I Function Connector Jumper Options Key way Termin
25. vent the host computer cannot communicate with the drive over the SCSI bus Enabling TIN allows the drive to re negotiate and maintain communication with the host If communication is lost on power cycles or drive resets at host boots setting the TIN Enable switch may solve the problem In general Microsoft systems may need TIN enabled AIX Unix and Linux systems typically need TIN disabled Plasmon UDO30D I Drive User Manual Getting Started Document Revision C Page 17 Setting Up the UDO30D for USB Connection For the USB version of the UDO30D a special cable and adapter are supplied These are shown below za M mue E s OR iS 2 x Figure 7 USB Connectors To connect the drive to a USB interface follow these installation steps 1 Attach the power cable and in line power supply to the drive 2 Attach the 68 pin SCSI connector on the supplied adapter to one of the drive s two SCSI connectors and the supplied SCSI terminator to the drive s second SCSI connector This is shown in the figure below Drive Power Cable SCSI Terminator SCSI Adapter USB to SCSI Cable Figure 8 USB Connections Getting Started Plasmon UDO30D I Drive User Manual Page 18 Document Revision C 3 With the drive and the host computer both powered on attach the USB connector on the supplied cable to a USB connector on the host computer and the SCSI connector on the cable to the 50 pin connector on the SCSI adapter attached to the dri