1. Gamex Lite 3 0 Program description and operating manual Issue No 3 0 Date of Issue 12 2013 Z U T NDT SOFT http www ndtsoft eu Gamex Lite 3 0 Program description and operating manual Copyright c 2013 by Z U T NDT SOFT All Rights Reserved Disclaimer Information in this document is subject to change without notice No part of this manual may be reproduced stored in a retrieval system or transmitted in any form or by any means electronic or mechanical including photocopying and recording for any purpose other than the purchaser s personal use without prior written permission from Z U T NDT SOFT The software described in this document is furnished under the software license agreement distributed with the product The software may be used or copied only in accordance with the terms of the license Trademarks The following trade names are referenced throughout this manual Microsoft Windows Win32 Windows XP Windows Vista Windows 7 Windows 8 are either trademarks or registered trademarks of Microsoft Corporation Other brand and product names are trademarks or registered trademarks of their respective holders E Gamex Lite 3 0 Program description and operating manual Contents TNTRODUCTION c a hea Ga a a canes balsa ale hareee aee naaa a a S E 4 PROGRAM INTERFACE Eeer Bi KEEN EKON RER EAEE ETE TA E Ei 5 SETTING PROGRAM OPTIONS ENTERING NEW GAMMA RAY SOURCES ss sssssrosesserroresee
2. Possibility to perform calculations for steel and nickel copper aluminum and titantum alloys Correct calculation of exposure times for single wall and double wall exposure techniques Integrated database of gamma ray sources with automatic calculation of their current activities Optional selection of preferred length mm or in and activity GBq or Ci units Program Help system and operating manual allowing quick and easy learning of program functionality Gamex Lite 3 0 Program description and operating manual 2 Program interface After successful installation and registration of the Gamex Lite program on your computer you can start it by double clicking on the shortcut icon placed by the installer on the Windows desktop Sk zj Gamex Lite Fig 1 Gamex Lite shortcut icon on the Windows desktop The program main window is displayed in fig 2 From this window you can reach all program functions options database and Help system There are two buttons placed on the top panel and four tabs placed on the main panel The Program Info button displays the form with the program name version and registration information If you have not registered the program yet this button is named Registration and serves as a starting point for the program registration procedure The Help button opens the program help system The Exposure time tab opens the main program page where exposure time and unsharpness calculations are
3. 0 Film system class c4 D5 T200 IX80 DI Radiograph density 2 5 4 gt Use exposure correction for no correction DI Exposure time gt gt E min 35 sec Ug mm omg Save technique View techniques Fig 6 Calculation of exposure time and geometric unsharpness Inthe combo box Tested material select the material to be tested You can select one of the five most commonly tested metals steel nickel cooper titanium or aluminum alloy s Inthe edit box Single wall thickness enter the wall thickness of the tested object You should always put here the single wall thickness even if you are using double wall exposure technique The thickness value should not exceed the limits defined by the governing radiographic standard e In the edit box Weld cap height enter the estimated height of the weld caps when testing welds In other cases enter zero 10 Gamex Lite 3 0 Program description and operating manual s In the radio group Radiographic technique select the radiographic technique you are going to use for exposure You should choose between single wall double wall single image and double wall double image techniques The selection is very important for correctness of exposure time and geometric unsharpness calculations If in the previous step you have selected the double wall double image technique elliptical examination you have to enter the external diameter of the tested object in th
4. aph when calculating the exposure time in the program standard mode without correction In edit box Test radiograph density obtained enter the optical density actually measured in the center of the developed test radiograph e After filling in all the above data click on the OK button to enter the new correction data to the program database From now on you can use this correction option in the subsequent exposure time calculations 8 Calculation accuracy The final accuracy and reliability of calculations executed with the Gamex Lite program depends on the correctness of input data entered by the user as well as on the careful implementation of the defined radiographic technique You should take special care about accuracy of such parameters as material thickness and source to film distance The sensitometric parameters film speeds characteristic curves assigned by the program to different film system classes C1 to C6 are not universal They should be considered as certain averages reflecting data published by film manufacturers and feedback data received from the Gamex program users The specific testing processing conditions in a particular laboratory can make these standard data not sufficiently accurate In such cases you should make use of the exposure correction system implemented in the Gamex program When all testing and processing conditions are kept under control and exposure correction system is properly used the expo
5. carried out The Gamma ray sources tab opens the page with the list of gamma ray sources stored in the program database On this page you may enter the new sources or delete or edit the other ones The Corrections tab opens the page with a list of exposure correction datasets entered to the program database On this page you may enter the new correction data derived from test radiographs Tab Options opens the page where you can select preferable length and activity units as well as choose the governing radiographic standard Gamex Lite 3 0 Program description and operating manual Registration Tested material Steel Single wall thickness mm 20 C double wall single image Weld cap height mm 1 5 C double wal double image Tube diameter mm 82 0 Gamma ray source Ir 192 Pig A DI Current activity Ci 65 5 Source to film distance mm 650 Film system class c4 D5 T200 IX80 DI Radiograph density 2 5 al gt Use exposure correction for no correction DI Fig 2 The main window of the Gamex Lite program Gamex Lite 3 0 Program description and operating manual 3 Setting the program options When you start the program for the first time you have to make some initial setup which as a minimum requires choosing the program options and specifying parameters of your gamma ray sources To set up the program options click on the Options tab in the main windo
6. e Tube diameter box For other techniques this parameter is not relevant and the corresponding box is not active s Inthe combo box Gamma ray source select the source which will be used for the planned examination After selection of the gamma ray source the program automatically calculates its current activity and displays it in the Current activity box You can overwrite this value manually if you want e In the edit box Source to film distance enter the distance between the gamma ray source and radiographic film which will be used in the planned examination s In the combo box Film system class select the class of film which will be used for the planned examination To ease your choice for each film system class the symbols of most popular film types are given in parentheses e In the box Radiograph density select the optical density required for your radiographs You can select density value in the range of 1 5 to 4 0 in 0 5 steps s The option Use exposure correction for is available only if you have entered relevant correction data in the Corrections tab This option may considerably improve the program accuracy If this functionality is active select the correction option i e combination of film type metal screens and processing mode conforming to your actual working conditions You may also select the no correction option to use the standard calculation algorithm After entering all these data click on the Exposure time butt
7. factor is always left to the user 7 2 The test radiographs The test radiographs are executed to obtain the data necessary for automatic calculation of correction factors by the Gamex Lite program Each test radiograph should represent one set of testing processing conditions in the user laboratory The significant variables are source type film type screens material and thickness and film processing mode For every practical combination of these factors one test radiograph should be executed The basic rules for executing test radiographs are listed below e All test radiographs should be made on carbon steel plates The thickness of the selected plate should be compatible with the source type and its exact value measured with a high accuracy equipment preferably with a caliper gauge s The exposure time for test radiograph should be calculated with the Gamex Lite program in its standard mode i e without correction The target density should be 2 5 or more The source to film distance SFD should be 500 mm 20 or more to avoid problems with precise control of short exposure times e The test radiograph should be executed in carefully controlled conditions with exact adjustment of SFD value and precise control of exposure time The film packet should be well protected from back scattered radiation 14 7 3 Gamex Lite 3 0 Program description and operating manual The test radiograph should be developed in well defined condit
8. g C Se 75 1236 2 9 50 0 2013 08 30 Pig D Yb 169 2347 1 0 4 0 2013 10 25 Add source Edit source Delete source Fig 4 Page displaying example gamma ray sources stored in the program database When you open this form for the first time you may find there some example entries which can serve you as templates for introducing your actual data You may review this examples by clicking on the Edit source button and edit their parameters to conform your actual sources Alternatively you may enter the new sources by clicking on the Add source button which opens the following form Gamex Lite 3 0 Program description and operating manual x Isotope bus d Source serial No bus Source size mm B Initial activity ci so Initial activity date 2013 10 31 gt Source container Pig E Fig 5 Entering parameters of new gamma ray sources In the above form enter the following data e Inthe sotope combo box select the type of your gamma ray source You may choose one of the four options Ir 192 Se 75 Co 60 or Yb 169 e Inthe Source serial No field enter the serial number of your gamma ray source It should be given in the source certificate e Inthe Source size field enter the size of your gamma ray source It should be given in the the source certificate or specification s In the nitial activity field enter the initial activity of your gamma ray source as indicated in its certificate The activity value may be ex
9. he exposure values calculated with the available exposure calculator Correction factors are determined on the basis of test radiographs by comparison of their planned and actually obtained densities This approach works reasonably well when testing conditions are much the same for all the jobs However in cases you have to remember several correction factors applicable to different testing processing conditions it inevitably leads to mistakes and improperly exposed radiographs To resolve this problem an automatic exposure correction system is implemented in the Gamex Lite program It allows for adjustment of the exposure calculation algorithm to virtually every testing processing conditions which may occur in the user laboratory The basic principle is the same as with manual calculations of correction factors For every practical combination of gamma ray source film type metal screens and processing conditions you make a test radiograph with exposure time calculated in the standard mode without corrections Then you measure the test radiograph density and compare it with the planned one Both values are then entered to the program database together with other parameters of the test exposure Having the test radiographs data stored in its database the program can automatically select the correction options matching the particular testing conditions and calculate the relevant exposure correction factor The final decision on the use of correction
10. ions processor model processing mode chemicals brand and its density measured with calibrated densitometer The density should be measured in the central part of the radiograph where the penetrated thickness is equal to the plate thickness The test radiograph density together with all other parameters of test exposure should be recorded and entered to the program database in the way described below Entering data from test radiographs To enter the data obtained from the test radiograph to the program database click on the Corrections tab in the main window and open the page shown in the fig 9 In the displayed table you can find all exposure correction data already entered to the program database eeeeEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEN Exposure time Gamma ray sources i Corrections Options Test radiographs data No Source Film class D_plan D_obt Test conditions 1 Se 75 C3 D4 MX125 Dani 2 5 1 90 Agfa D4 Pb 0 025 0 025 Auto G135 3 2 TIr 192 C4 D5 T200 X80 2 5 1 90 Kodak T200 Pb 0 027 0 027 Auto 30 3 Ir 192 C4 D5 T200 X80 2 5 2 17 Fuji X80 Pb 0 100 0 100 Auto 30C 6 New data Edit data Delete data Fig 9 Exposure correction data stored in the program database To enter the new data set obtained from the new test radiograph perform the following steps 15 Gamex Lite 3 0 Program description and operating manual e Click on the New data button and open
11. on and the program will calculate exposure time and geometric unsharpness for the entered exposure parameters The unsharpness value Ug will be displayed in different colors depending on whether it meets the requirements of the referenced radiographic standard specified in the program options For ISO 17636 1 EN 444 option it will be displayed in red if it does not meet the requirements of Class A If it meets the requirements of Class A but not the Class B it will be displayed in blue In cases it meets or exceeds the requirements of Class B it will be displayed in black For ASME V option it will be displayed in red if it does not meet the requirements of article T 274 2 of Section V If it meets these requirements it will be displayed in black All parameters of defined radiographic technique can be saved for printing by clicking on the Save technique button You can prepare and save several techniques in one program session All saved techniques can be reviewed in the separate program window opened by clicking on the View techniques button Printing of radiographic techniques is described in the next paragraph 11 Gamex Lite 3 0 Program description and operating manual 6 Printing of radiographic techniques Saved radiographic techniques can be reviewed in the separate program window opened by clicking on the View techniques button in the Exposure time tab Each technique is shown in one row of the table with all basic parameters tes
12. pressed in GBq or Ci depending on the choice you have made in the program options s In the Initial activity date field pick up the date of the initial activity measurement This date should be given in the source certificate together with its activity value e In the Source container field enter the short identification symbol number of the container projector your gamma ray source was loaded in It should unambiguously identify the source for all works performed by the laboratory After entering all above data click on the OK button and find your new source in the table of sources displayed on the Gamma ray sources tab From now on you may use this source in program calculations In the same way you should enter all other sources used in your laboratory 9 Gamex Lite 3 0 Program description and operating manual 5 Calculation of exposure time and geometric unsharpness To calculate the exposure time and geometric unsharpness for your radiographic technique select the Exposure time tab in the main window and proceed on the following page Exposure time Gamma ray sources Corrections Options m Radiographic technique Ge single wall Tested material Steel e Single wall thickness mm 20 0 C double wall single image Weld cap height mm 15 C double wal double image Tube diameter mm 82 0 Gamma ray source Ir 192 Pig A DI Current activity Ci 65 5 Source to film distance mm 65
13. rrressrreessetesrrrerssrrersserersseress sree CALCULATION OF EXPOSURE TIME AND GEOMETRIC UNSHARPNESS t erseeree 10 PRINTING OF RADIOGRAPHIC TECHNIQUES EXPOSURE CORRECTION SYSTEM LA ONTI INON ACCURACY AA E EE E eeh deet A E D Gamex Lite 3 0 Program description and operating manual 1 Introduction Gamex Lite is an advanced exposure time and geometric unsharpness calculator for conventional film radiography carried out with gamma ray sources It is designed to provide basic support for RT personnel directly involved in planning and executing of radiographic exposures Gamex Lite will operate on the following Windows platforms Windows XP Windows Vista Windows 7 and Windows 8 The program offers the following functionality Calculation of exposure times and geometric unsharpness for radiographic techniques executed with Ir 192 Se 75 Yb 169 and Co 60 sources in dependence of tested material thickness exposure geometry source to film distance film type and required optical density of radiographs Automatic checking if calculated geometric unsharpness meets the requirements of major international standards such as EN ISO 17636 1 EN 444 or ASME V Printouts of instruction sheets with all parameters of radiographic techniques defined during exposure time calculations Advanced corrections system enabling adaptation of the exposure calculation algorithm to the specific testing processing conditions in the user laboratory
14. stance Geometric unsharpness Exposure time Exposure correction Technique 2 Gamma ray source Source activity Film class Required density Tested material Exposure geometry Single wall thickness Weld cap height Source to film distance Geometric unsharpness Exposure time Exposure correction 2013 11 28 Ir 192 Pig A 50 4 Ci C4 D5 T200 IX80 2 5 Steel single wall 20 mm 2 0 mm 550 mm 0 11 mm Class B 3 min 25 sec no correction k 1 00 Se 75 Pig C 50 3 Ci C4 D5 T200 IX80 2 5 Steel double wall double image 6 3 mm 15mm 550 mm 0 48 mm Class A 6 min 53 sec no correction k 1 00 Fig 8 Example printout of two radiographic techniques 13 Gamex Lite 3 0 Program description and operating manual 7 Exposure correction system 7 1 General description The common weakness of all conventional exposure time calculators exposure charts sliding rulers simple programs is that they implement a fixed calculation algorithm which is valid only for a certain set of testing processing conditions Unfortunately working conditions are not the same in every radiographic laboratory They use different brands types of films metal screens and film processing systems All these factors may lead to discrepancy between expected and actually obtained film densities To resolve this problem radiographers often determine so called correction factor which is used to multiply t
15. sure times calculated with the Gamex Lite program should ensure radiographs densities not differing more than 0 2 0 3 from the planned values 17
16. ted material wall thickness source SFD etc displayed in the successive columns The example table with 3 saved techniques is shown in fig 7 Radiographic techniques x Radiographic techniques saved for printing No Material Thick Technique Source SFD Film Dens Exp time Correction 20 0mm Single Wall Ir 192 Pig A 700mm C4 D5 T200 2 5 3min 55sec no correction k 12 0mm Single Wall Se 75 Pig C 700mm C3 D4MX125 2 5 8min 49sec no correction k 35 0mm Double Aal Co 60 Pig B 900mm C5 D7 AA400 2 5 34min 18 sec Kodak AA400 Fig 7 Table of radiographic techniques with 3 entries saved for printing In this window you may decide which techniques are to be printed To delete a technique from the list place the cursor on its row and click on the Delete selected button After removing all unwanted entries you can print out the remaining techniques by clicking on the Print All button The printouts will contain all parameters necessary for exposures execution by qualified personnel The example printout of two radiographic techniques is shown in fig 8 The printouts can be handed over to RT crews going to the job for their technical reference 12 Gamex Lite 3 0 Program description and operating manual Gamex Lite 3 0 Technique 1 Gamma ray source Source activity Film class Required density Tested material Exposure geometry Single wall thickness Weld cap height Source to film di
17. the form named New correction dataset shown in fig 10 s Inthe combo box Jsotope choose the type of gamma ray source used for test radiograph exposure e Inthe combo box Film system close select the film system class of the film used for the test radiograph s In the edit box Film brand type enter the specific brand type of the film used for the test radiograph BER Isotope ir 192 D Film system class c3 D4 MX125 IX50 D Film brand type Agfa D4 Screen material Pb X Front screen thickness mm 0 027 Back screen thickness mm 0 027 Film processing Auto 6min 30C Test radiograph density D planned 2 5 obtained 2 15 Fig 10 Entering new correction data set obtained from the test radiograph s In the combo box Screens material select the material of metal screens It will be Pb for most cases but for Co 60 exposures you can also select Fe or Cu screens e Inthe edit box Front screen thickness enter the thickness of the front metal screen e In the edit box Back screen thickness enter the thickness of the back metal screen 16 Gamex Lite 3 0 Program description and operating manual In the edit box Film processing describe the type mode and parameters time temperature of chemical processing used for development of the test radiograph s In the edit box Test radiograph density planned enter the optical density planned for the test radiogr
18. w and open the following page eteoeoseressseosovesososeovosososeovosovoroseosovososesvovssososes Exposure time Gamma ray sources Corrections Options Length units Activity units Metric mm m Gigabequerels GBq Imperial US in ft Curie Ci Applicable standard ISO 17636 EN 444 ASME V Fig 3 Selection of program options In the left option box select the length measurement units you prefer to work with You can choose Metric or Imperial US system In the upper right option box select the activity units you prefer to work with You can select Gigabequerels GBq or Curies Ci In the lower right option box select the standard you are working with This selection determines how the program will evaluate the calculated geometric unsharpness You can change the program options at any time Gamex Lite 3 0 Program description and operating manual d Entering new gamma ray sources Before starting normal program operation you need to enter parameters of your gamma ray sources to the program database Click on the Gamma ray sources tab in the main window and open the following page Exposure time Gamma ray sources eteeseosorereseoeoeoeososeoeoroseseocososoeeseoeosorosesroreseses Gamma ray sources Corrections Options Container Source Source No Source Size Init_activity _Init_date Pig A Tr 192 1001 3 0 135 0 2013 08 15 Pig B Co 60 4599 4 0 60 0 2010 10 20 Pi
Download Pdf Manuals
Related Search
Related Contents
Life Fitness M051-00K26-A261 User's Manual treadmill owner`s manual manuel du propriétaire UNO-4678 User Manual Taxe de séjour : mode d`emploi TP-LINK Archer C8 BF-679W/BF-680W Body Fat Monitor / Scale Digipass parlant - mode d`emploi Toro Quick-Connect Perimeter Lighting Design Guide Mode d`emploi (Traduction) Transmetteur de valeurs limites Copyright © All rights reserved.