Home
POWER CONTROL
Contents
1. reve Eder 28 AE XPOR TB UU ON EN ME 29 1 Introduction Power Control is a program specially designed to control and supervise the energy consumption of an installation allows to configure power calendars create installation loads and loads groups define connection timetables and loads disconnection display real time graphs of the consumption progress and loads connection and disconnection The program allows to simulate it before we do the final supervision Moreover we can export data and also we can do a consumption report of specified period 2 Menus When we open Power Control presentation window appears If we click over it the main screen will appear There we ll be able to configure the program The available options in the program menu are e File e Options Graph e Information 2 1 File In File menu option we can select or open the work path where there are all the configuration files of the program and the installation we want to supervise The available options in File menu are 2 1 1 New It allows selecting the new work path Once we have selected it the program will create all the configuration files If the files are already created it will delete them and it will create files without information POWER CONTROL MANUAL Select work directory Load cfg LoadCalendar cfg LoadTimeT 2 1 2 It allows selecting
2. m CIRCUTOR CIRCUTOR Vial Sant Jordi s n 0623 2 Viladecavalls Barcelona SPAIN Tel 34 93 74529 00 Fax 34 93 745 20 14 e mail central circutor es web www circutor com SOFTWARE POWER CONTROL USER S MANUAL Cod M 981 450 01A 2001 CIRCUTOR S A All rights reserved POWER CONTROL MANUAL 1 IN TRODUG TION MENUS Ps a OR oe ne ETE 3 2 12 ODOM 4 2 1 9 all OU steh metals E 4 Pilg E ME d eee RN RR RR RR RERO 4 PALA A NONO ELLE DE 5 2 2 1 Parameters 5 9 2 2 3 Installation simulation eee 13 2 2 4 Installation 10 18 2 2 5 F 1 23 PIN CI F X 23 2 INFORMA 24 3 POWER CONTROL 25 3 T EVENTS BUTION den aee 25 3 2 SELECTION BUTTON 26 3 3 THROUGHPUT BUTTON em eee ae 27 34 CONSUMPTION BUTTON ER ES Ease uU s Fe
3. Address Expansion peripheral address 1 42 Position in Position where the load is connected 1 3 12 POWER CONTROL MANUAL Calendar Calendar selection to the connection and disconnection of the load About more information see Loads calendar section Modify It allows modifying the selected load data in the loads list Delete It allows deleting a load from the loads list 2 2 3 Installation simulation It allows doing a simulation with the groups loads and parameters that we have configured in the program a Simulation Will appear a list with all the configured loads a simulation parameters and the consumption evolution in real time graphically To start the installation we must click over OFF image and if we want to stop it we must click over ON image The following screen will appear Industrial plant simulation Ej rn al CN cx cwn 811 5834 Lega T Ld rep Dues gemis denm m i E Lael HE lum TEM 251 Ad EC Simulation parameters Date and Time Will appear the date and time of the simulation in real time We can modify and introduce other date and time Speed Number of iterations by second It s the load simulation speed Maximum power When we click over the button on the right the target value will be the
4. 3 Power Control buttons Then there is information about the most common buttons of the simulation and supervision screens 3 1 Events button In the simulation or supervision displaying will appear a window where the events of a specific day or time period will be showed The following window will appear Events Supervice 10 00 00 10 08 36 10 08 38 Synchrony __ DAS power fail 10 08 40 Los commurnicaction with Mr3 1 10 08 40 Liner inachve Load 1 10 08 55 CAA power fail 10 09 00 stant up 10 03 02 Last communicaction with brs 1 10 09 02 User inactive Load 1 10 15 00 Synchrony 10 30 00 5ynchrony 10 45 00 Synchrony 11 00 00 11 04 02 Cd up 11 04 04 Last communicaction with bers 3 2 11 04 04 Last commurnicaction wth Mrs Mid 1 11 04 04 Lost communicacion wth Mr3 Mi 11 04 04 Last communicaction with r3 Mr3 4 11 04 04 Uzer inactive Load 2 11 04 04 User inactive Load 1 11 04 04 Use Load 4 11 04 04 Use inachve Load 5 11 04 04 User inactive Load 11 04 04 User inactive Load 5 11 04 04 Liner inactive Load 3 11 15 00 Synehrony 0 10 00 00 11 88 59 23 Export Exi 25 POWER CONTROL MANUAL Buttons Select the time period we want to show Go back in the time period 9 Go forward in the time period Export the data to text file or data base format
5. Active Inactive All All active loads Active Active loads Inactive Inactive loads Disconnected Disconnected loads If we right click over a load will appear a menu like this Force active Force disconnect D Free Force active The controller won t be able to disconnect the load Force disconnects The controller will disconnect the load but it wont be able to connect again Free It will remove any forced status in a load to continue with its normal status Historics A real time historic of the installation will be displayed If we click over the Historics folder the following screen will appear 19 POWER CONTROL MANUAL When we do the supervision the program creates a STD file where it saves the values it is registering This file saves the data each month The graph and events representation are data that this file contains In previous screen appears the file name where the data is stored The initial and final date of the file is displayed In the graph appear the simulation consumption KWh the target value and the average power of the simulation KW avg The representation in the time graph is about a whole day If we click over the graph will appear a cursor that we can use with keyboard arrows to move for each value of the graph and we can display what each graph point means On the right side of the graph appear the showed values in the graph which are stored
6. same that the main calendar If it isn t pressed we ll be able to introduce a target value Average power It s the average power value of the installation 13 POWER CONTROL MANUAL ON OFF button It starts or stops the installation simulation In the list where there are the configured loads in the system if we right click a menu will appear and there well be able to select the loads we want to display NP Active Inactive 1 Disconnected All All the loads Active Active loads Inactive Inactive loads Disconnected Disconnected loads Also if we right click over a load a menu like the following menu will appear tal Force active al Force disconnect D Free Force active The controller won t be able to disconnect the load Force disconnect The controller will disconnect the load but it wont be able to connect again Free It will remove any forced status in a load to continue a normal status operation Historics An installation simulation historic will be displayed The following screen will appear if we click over Historics folder 14 POWER CONTROL MANUAL When we do the program simulation it creates a STD file where it saves the values are registering This file saves the data each month The graphs and events representation are data that the program saves in this file In the previous screen appears the name of the file where the data is stor
7. 23 P m 02 04 05 06 07 Q8 11 12 13 14 15 16 17 9 19 20 20 22 23 P MAI A 00 02 03 4 05 06 07 08 20 22 23 7 D E I 1250 Ew mu 5650 Ew 1000 Fw 11530 Fw 12000 Ew m 1500 Fw E 5175 Ew x Ok X Cancel Advanced A screen where we can configure delay time between actions and reconnection POWER CONTROL MANUAL Delay between actions Time in seconds 2 250 to take a decision about the loads control Reconnection time Time which won t be reconnected more loads at the end of the period 0 250 Advanced Alarms A screen where we can enable a control alarm appears This alarm will be activated where the controller hasn t got more loads to control and the real value is over the demand value When the alarm is activated the following button appears in the up right side of the installation windows in the two modes simulation and supervision The alarm will be disabled if we click over the button or if we wait the stablished time in the dialog box If the time is 0 we must click over the button to stop it Password It allows locking the window Once we have introduced the code we won t be able to do any action on the program POWER CONTROL MANUAL 2 2 2 Configure It allows configuring the loads groups and only the loads a Groups We ll be able to add new groups modi
8. 8 13 0 21 22 2 26 27 2B 29 J Select day we want to show in graph or events table Go back a day in the file BH Go forward a day in the file a aca Y Select the time period we want to show in the 0 Go back in the time period Go forward in the time period Selection Display the screen of the data we want to show in the graph See Power Control buttons section for more information Throughout Display the loads throughput screen See Power Control buttons section for more information Events Display the events screen of the selected day and time period See Power Control buttons section for more information 22 POWER CONTROL MANUAL ___ Upload the data with the new data of the file 2 2 5 Lock Unlock If we click over Lock Unlock option we can lock the software window so we wont allow to do actions with the installation to non authorized people If we want to unlock it we ll need a password When the software is locked this icon amp will appear in the communication icons 2 3 Graph The options of the Graph menu are common to all the graphs that are in the program However if we click over the graph and then we right click over it again the following menu will appear Graph Undo zoom Print Plothrig methad HH Grid lines Grid in front Undo zoom If we want to do a zoom over the g
9. See Export Button for more information 3 2 Selection Button In the simulation or supervision displaying will appear a window where we can select the parameters we want to show in the events graph The following screen will appear Selection 26 POWER CONTROL MANUAL We can select different types of parameters Loads Loads we have configured in the installation Expansion peripherals we have configured in the installation Other Any other data to display Buttons Add to the Show box list the parameter we have selected Remove from the Show box list the parameter we have selected Priority to display graph 3 3 Throughput button In the simulation or supervision displaying will appear a window where will be showed the time percentage that the installation loads of selected day have been enabled The following screen will appear Loads trowghput 2 27 POWER CONTROL MANUAL In the loads column appears all the installation loads and in the throughput column appears the time percentage of each load This throughput is the selected day in the visualization or supervision screen 3 4 Consumption button The addition of the energy consumptions divided by tariffs will be displayed We can select the period we want to show the consumption addition A list will appear with 8 types of tariffs with the target value for each tariff and the final consumpt
10. a work path where the files of a previous installation are 2 1 3 Language It allows choosing the program language The available options are Spanish and English Power Control C Program FileskCicutorkPowerCN 2 1 4 Exit ends the program execution POWER CONTROL MANUAL 2 2 Options In the Options menu option we can modify the operation parameters of the program unless select the groups and loads configuration screen or the simulation or supervision screens of the installation The available options in Options menu are 2 2 1 Parameters Appears a window with several options to configure the program operation Portege nem ton ps bagra parod 5 rere atc tg T Erj palra 1 3 Ea probis a Com Sorel a Pood Ma E wie C Sahay E E Parameters Integration period Time in minutes where the values will be integrated KWh by pulse Consumed energy value by pulse External synchrony pulse Indicates what kind of pulse we want External pulse or controlled for CA 4 pulse Window type Indicates the type of work mode The type of window we can select can be Fixed When there is a synchrony pulse the control period will reboot INTEGRATION TIME Sliding It will give to each integration window a synchrony pulse ac
11. cording to the last control period POWER CONTROL MANUAL INTEGRATION TIME INTEGRATION PERIOD Control It will select the parameter we want to control in the installation KW Active power KVA Aparent power Sliding window parameters It will be enabled if we select sliding as type of window Integration time It s the period where the programmed value will be integrated Exceed It s the value percentage that increases the allowed consumption in each integration window 0 30 Simulation parameters They are the parameters that will be used in a simulation of the installation No controlled load It s the power consumption value that the controller doesn t control Variation factor Its the value percentage that modifies the power consumption to obtain a no constant consumption in the simulation 0 20 Clock It reads the internal clock of CA 4 that is connected to the PC Then a screen appears there we can modify date and time and send them to the device If we check Syncrhonize clock with synchrony pulse option the internal clock will be synchronized with the external pulse Config clock Date time lunes 2001 g5 17 __ Sendtocas Send PC time J 1 I SERIE UT E wf Ok 3 Cancel POWER CONTROL MANUAL Historics A s
12. creen where we can select the parameters that will be saved to historics file appears Power Lontrol Save events Me CAd start up Controler connect by lime I power fal I Controler connect by timetable v Lost communicacton with Mr3 Iv Controler inactive by timetable v Establish communication vath Mrs v User connect Synchrony v User inactive v Controler inactive User force connect Controler connect Iv User force disconnect V Controler disconnect 7 iLiser hee wf Ok Cancel Calendar It allows configuring the maximum contracted power calendar We can configure maximum 8 types of days with eight types of different target values Day types IBI gt 00 02 03 04 05 06 07 0 10 11 12 13 14 15 16 177 18 19 0 2 22 23 00 01 02 04 05 06 07 08 10 12 13 14 15 16 17 18 19 20 21 2 23 ME 2 00 01 02 03 06 07 0 10 11 12 13 14 15 16 17 18 19 20 21 22 23 A a ANY JL E UL 00 01 02 03 04 05 06 07 08 10 11 12 13 14 15 15 12 18 19 2 22 23 00 01 02 03 04 05 06 07 08 10 1 12 13 14 15 16 17 18 19 20 21 22 23 MHIL AA M DUE UE UE UE 00 01 02 03 04 05 06 07 08 09 10 11 12 13 14 15 16 17 18 19 20 21 22
13. ed The initial and final date of the file is displayed In the graph there are the simulation consumption KWh the target value and the average power of the simulation KW avg The time representation in the graph is about one day If we click over the graph will appear a cursor that we can use with the keyboard arrows to move for each graph value and we can display what each graph point means On the right side of the graph there are the values of the graph and they are stored in STD file Buttons 2007 mi wu i Select the day we want to show in the graph or events table Go back a day in the file 15 POWER CONTROL MANUAL Go forward a day in the file 1 Events Show the events screen of the selected day See Power Control buttons section for more information Upload the data with the new data of the file 5 CF z Export the data to text data base format See Power Control buttons section for more information Consumption Show the energy consumption See Power Control buttons section for more information Events The events of the simulated installation will be displayed The following screen will appear when we click over Events folder ee rFiririririririr t n ILTLTLTLTLTLTLTLTLTLTL When we do the simulation the program creates a STD file where it saves the simulation values that it registers This file
14. fy existing groups delete previous groups Moreover we ll be able to add or delete loads from a group POWER CONTROL MANUAL Groups list with configured groups appears The actions will be able to do are Add It allows creating a new group Add new group Name Word to identify the loads group Disconnection sequence FIFO First in first out The order of the loads doesn t influence the first time later it depends on the load we have to disconnect Last in first out normal stack Disconnection order There is an order to disconnect the loads Modify We can modify the data of selected group To confirm the changes we have to click over Accept button To cancel the changes we have to click over Cancel Delete Selected group will be deleted A message to confirm the group removal will appear If we press Yes the group will be deleted from the list Group loads list with all the loads of selected group appears The actions will be able to do over the loads are Add A window with all the loads isn t of the selected group but they can be in other groups appears We can select and change the group clicking over Accept 10 POWER CONTROL MANUAL E Add load to group Group 2 1200 00 4200 00 2 zz 5200 00 i 500 00 Delete It allows deleting loads from the group that we have selected previously A message to confirm the
15. in the STD file Buttons julio de 2007 Select the day you want to display in the Go back a day in the file Go forward a day in the file 20 POWER CONTROL MANUAL O Display the events screen of the selected day See Power Control buttons section for more information __ Upload the data with the new data of the file _ Bim Export the data to a text file or a data base format See Power Control buttons section for more information __ Display the energy consumption See Power Control buttons section for more information Events The installation events will be displayed in real time The following screen will appear if we click over Events folder When we do the program supervision the program creates a SID file where it saves the values are registering This file saves the data each month The graph and events representation are data that this file contains In the previous screen there is the file name where the data is stored The initial and final date of the file is displayed In the graph there are the data connection and disconnection that we have selected previously The time graph representation is a two hours period If we click over the graph will appear a cursor that we can use with 21 POWER CONTROL MANUAL keyboard arrows to move for each graph point and also we can use it to show the time of this point Buttons 11 12 13 14 15 1
16. ion in this period for each tariff The following screen will appear Lonsumption Buttons _ Upload the displayed data It will be enabled when we modify the period we want to display 28 POWER CONTROL MANUAL 3 5 Export button It allows exporting the data in the selected period to text or data base format The following screen will appear Histonc export Type of file Text TXT MDB Microsoft Access Data Base file If we select text format this field will be enabled Fixed length register The registers fields will have the same length Variable length register The registers fields will have variable length and we ll specify the fields and registers dividers Period We ll specify the period of the data we want to export 29
17. loads removal will appear If we press Yes the selected loads will be deleted from the list a Loads We ll be able to add new loads modify existing loads or delete previous loads The following screen will appear 11 POWER CONTROL MANUAL Add It allows adding new loads to the installation The following screen will appear wad Treas J bis re Ae co coe Pom s ves inn LS Pinter J i aE arara s mi a Hornak D H rana Loads Name Load name Identification Name to identify the load in the installation Power Maximum power of the load Variation factor Value percentage that modifies the power consumption to obtain a no constant consumption in the simulation 096 20 Time Maximum disconnected Maximum time that the controller may has a load disconnected Minimum disconnected Minimum time that the controller Should has a load disconnected Minimum connected Minimum time that the controller should has a load connected Input CA 4 and Mr 3 inputs allowed software to know load status The input function is to know if load 15 activated or stopped Output Software use CA 4 and Mr 3 outputs to active or stop loads Group Group selection where we can find a load Order Load priority in the loads group to verify the load and unload times
18. of the file 2 2 4 Installation supervision It allows doing real time supervision with configured groups loads and parameters of the program It checks the controller configuration with the software configuration when we click over supervise mode a Installation A list appears with all configured loads taken parameters in real time and the consumption evolution in real time graphically The supervision will start when the screen appears we have communicated with the controller previously and the communications with the program are correct If doesn t exist communication with the controller we won t be able to supervise the installation in real time brer orbel gt l Frapan LI slbi a Geh p gt gt Tin mmm SS cmm 5 Loue leger Ht Supervision parameters Date and Time The date and time of the supervision will appear in real time We can modify and introduce other date and time Maximum power The target value will be the calendar target value we have assigned in the configuration Average power It s the value of the average power of the installation 18 POWER CONTROL MANUAL Send configuration It sends the configuration to the controller If we right click over the list where the configured loads are displayed or if we click over the Filter button a menu will appear where we ll be able to select the loads we want to show NP
19. raph we must keep pressing the left button of the mouse and then we must drag the mouse then a square will appear Once we have selected the area we have to keep out the left button of the mouse and the zoom will be done This option will display the graph to its initial status again Print The displayed area of the graph is printed Plotting method The graph can be displayed in three different modes Line default Point Point and line Grid lines It will be selected if the graph is displayed with separation lines There are four options Both Horizontal Vertical 23 POWER CONTROL MANUAL None default Grid in front It must be selected if we want to show the separation lines in front of or behind the graph 2 4 Information In the Information menu option there is information about the device and program The following menu will appear Device Device window with controller information and serial number will appear type and version Device infomation Device infcemation Power Cemtial Versi n 1 02 Serial number 324030008 x Ok About The presentation screen will appear m CIRCUTOR CIRCUTOR Vial Sant Jordi s n 08232 Viladecavalls Barcelona SPAIN Tel 44 93 74529 00 Fax 34 93 745 29 14 e mail centrall circutor es web waw circutor com 24 POWER CONTROL MANUAL
20. saves the data each month The graph and events representation are data that it saves into this file In the previous screen appears the name of the file where the data is stored The initial and final date of the file is displayed In the graph there are the data connection and disconnection that we have selected previously The time representation is a two hours period If 16 POWER CONTROL MANUAL we click over the graph will appear a cursor that we can use with the keyboard arrows to move for each graph value and we can display the time of this point On the right of the graph there are the values of the graph and they are stored in STD file Buttons julio de 2001 lun mar jue wi 25 2 7 28 729 30 1 4 11 12 13 14 18 13 20 2 zh 26 z7 26 1 Select the day we want to show in the graph Go back a day in the file Go forward a day in the file eee Select the period time we want to show in the graph or events table O Go back in the time period O I Go forward in the time period Selection Display the data selection screen we want to show in the graph See Power Control buttons section for more information t Display the load throughput screen 17 POWER CONTROL MANUAL E Events Display the selected day events and time period See Power Control buttons section for more information _ Upload the data with the new data