1. www scintex com au sales scintex com au Model SNADFM03 Auto Shut Off Nozzle with Digital Meter User s Manual A N WARNING Read carefully and understand all INSTRUCTIONS before operating Failure to follow the safety rules and other basic safety precautions may result in serious personal injury Save these instructions in a safe place and on hand so that they can be read when required 1 INTRODUCTION 1 1 Technical Data 1 1 1 The liquids compatible with Auto shut off digital nozzle must be at low viscosity namely as below Model No SNADFM03 Up to 6 OLPM 16GPM Operating 50psi 3 5bar pressure Max Operatin j 3 10C 50 C 14 F 122 F temperature Fluid type Diesel amp kerosene 7 Digit non resettable total 1 9999999 Unit Liter Gallon Pint Quart Inlet and outlet 3 4 1 3Kgs 2 7 Ibs Power supply 2 X AAA 5 Digit present total 0 01 999 99 1 2 LCD DISPLAY The LCD of the meter features two numerical Registers and various indications displayed to the user only when the applicable function so requires KEY Partial register 5 figures with moving comma from 0 1 to 99999 Indicating the volume dispensed since the reset button was last pressed Indication of battery charge Indication of calibration mode Indication of resetting present total to Zero Total register Indication of flow rate mode Indication of unit of measurement of part
2. h lala ai to paragraph 3 3 amp 3 4 measurement check the FACTOR meter works below Increase the flow rate until an acceptable minimum acceptable flow rate flow rate range has been achieved Reduced or zero Turbine blocked Clean the turbine ee The meter does Incorrect installation of turbine Repeat the reassembly process not count but the flow rate is correct Possible electronic card Contact the dealers or manufactures problems 5 DIAGRAM AND PARTS LIST Weis bea Te Seow a eo Spout
3. ht press the MENU key Keep it pressed until quit calibration mode the factor is saved The meter goes to standby again Press the MENU key Keep it pressed until similar with the image showed the digit flash in L zone it 3 4 MODIFY THE CORRECTION FACTOR IN FIELD PLEASE CAREFULLY FOLLOW THE PROCEDURE INDICATED BELOW Wait for the meter to go to standby IILE hott ih RESET TOTAL Reset the resettable total 3 Start dispensing into a measuring glass Por Stop dispensing when over 5 Litres of volume is reached read out the actual value The volume that is displayed on the LCD is the Display Value not the Actual Value which may be slightly higher For example in the figure on the right the Display Value is 18 96 while the Actual Value is 20 75 E Press the MENU key Keep it pressed until showed as the right fig the digit flash in L zone Press the RESET key to choose the right digit from 0 to 9 n Press the MENU keyt the th t digit so that sale ye e the next digit so tha 1D TUCE the Actual Value can be input Make sure the correction factor is right and then press the MENU key Keep it pressed until calibration l l is finished and the factor is save The meter will then ILI E RESET TOTAL return to standby 17 J 7 CF 7 4 MALFUNCTIONS Problem Possible Cause Corrective Action LCD no indication Bad battery contact Check Check battery contacts contacts Imprecise Wrong FACTOR Wit
4. ial L Litres 2 GAL Gallons l PT Pints QT Quarts 1 3 USER BUTTONS The turbine digital meter features two buttons MENU and RESET which individually perform two main functions and together other secondary functions The main functions performed are For the reset key resetting the partial Register and reset table total reset total For the menu key entering instrument calibration mode Used together the two keys permit entering configuration mode 1 4 BATTERY REPLACEMENT When replacing the battery please open the cover remove the plug and replace the battery 2 INSTALLATION This nozzle is designed to dispensing diesel fuel under 0 5 3 5bar 7 50psi pressure system 2 1 Connect the nozzle directly with the delivery hose Please be ensured the thread is sealed 2 2 Turn on the dispenser open the trigger of nozzle to start dispensing For first time using it is necessary to turn the trigger on and off 2 3 times to discharge the air inside 2 3 After dispensing turn off the nozzle and take back to nozzle holder 3 METER SETTING 3 1 BUTTON USAGE CALIBRATION AND MEASUREMENT UNIT CHANGE Reset the present total See Fig 2 1 When the meter is on standby press the RESET key 2 The display shows all the segments 3 The meter resets the present total already Fig 2 UE Tage a Da hs 123458 Show current correction facto
5. r and general total See Fig 3 Press MENU and RESET together and hold for two seconds Lol HT fi Value 1 4000 is the correction factor which can be reset LI LI LI 1234567 is the general total which cannot be reset M as Fig 3 Measurement unit change See Fig 4 Press MENU and RESET together and hold for five seconds Zone on the display is the current unit Press RESET to chose a different measurement unit and then press MENU to confirm Fig 4 3 2 RESET THE RESETTABLE TOTAL See Fig 5 When the meter is on standby press the RESET key for 2 seconds to reset the present total first Fig 5 nooo nooog B88888 3 3 PROCEDURE FOR ENTER THE CORRECTION FACTOR DIRECTLY Carefully follow the procedure indicated below FORMULA Proper correction factor current correction factorx actual value display value Example Actual value 20 75 Display value 18 96 Current correction factor 1 000 Proper correction factor 1 000x 20 75 18 96 1 000x1 094 1 094 Wait for the meter to go to standby IIU Ltt i RESET TOTAL 45D Reset the resettable total means the meter is in correction factor modification mode Press the RESET key to choose the right digit from 0 to 9 Press the MENU key to start the next digit So the digit of correction factor can be changed one by one Make sure the correction factor is rig
Download Pdf Manuals
Related Search
Related Contents
USER MANUAL LM-THF104 HDMI Fiber Optic Transmission 024129-F Applikator A Primer of 联 创 电 器 - Mconfort TIMS 301 User Manual OPERATION & SERVICE MANUAL F2000 CUTTING SYSTEM Unidad 2 - Facultad de Trabajo Social Nikon S4200 Digital Camera User Manual How to Install and Use the Model 1154A Signal StreetTrek™ User Manual - Comtran Associates Inc. Copyright © All rights reserved.