Home

Safety User Manual

image

Contents

1. Certificate No Sira O8ATEX1293X Certificate Type 0518 CEG x 0518 CE IM2 Ex Ex d IIC T4 Gb Ex d IM b Ambient Temperature Tamb 20 C to 50 C Power Supply 1x CorDEX Instruments XP Battery pack Part Number CDX 2341 801 EC DECLARATION OF CONFORMITY We hereby confirm the conformity of the equipment listed below with the directives of the Council of the European Community The safety and installation instructions of the product documentation must be observed European Standardsand Directives ATEX CERTIFICATE sira CERTIFICATION EC TYPE EXAMINATION CERTIFICATE Equipment intended for use in Potentially Explosive Atmospheres Directive 94 9 EC Certificate Number Sira 08ATEX1293X Issue 0 Equipment Centurion XP flameproof digital camera Applicant CorDEX Instruments Limited Address Unit 6 Farfield Main Road Wykeham Scarborough YO13 9QD UK This equipment and any acceptable variation thereto is specified in the schedule to this certificate and the documents therein referred to Sira Certification Service notified body number 0518 in accordance with Article 9 of Directive 94 9 EC of 23 March 1994 certifies that this equipment has been found to comply with the Essential Health and Safety Requirements relating to the design and construction of equipment intended for use in potentially explosive atmospheres given in Annex II to the Directive The examination and test results are recorded in the con
2. pack is secured using the screws provided If the screws are lost only replace with screws of the correct size and type If in doubt contact your nearest CorDEX Instruments representative e The Centurion XP Series digital camera is manufactured from aluminium alloy with less than 7 magnesium by weight and incorporates toughened glass windows This should be taken into account when considering the end use application e The Centurion XP Series digital camera cannot be maintained in the field and must be returned to the manufacturer should repair or maintenance be required e USB communications with the Centurion XP Series digital camera must only occur within the non hazardous area The cautions contained in this section do not relate specifically to safe use in hazardous area applications but should be followed to help prevent damage to the camera or personnel e Do not fire the flash close to anyone s eyes This might cause damage to the person s eyesight e Keep out of the reach of children e Acamera is a precision instrument Do not drop it strike it or use excessive force when handling the camera This might cause damage to the camera e Donot wrap the camera or place in cloth blankets e Use the camera in a well ventilated place e Before you move the camera disconnect the cords and cables MAINTENANCE For safety critical maintenance please refer to EN60079 17 4 CERTIFICATION Model Centurion XPG XPM2
3. CONTENTS 1 READ THIS FIRST 1 READ THIS FIRST Liability Trademark Information Product Information 2 SPECIAL CONDITIONS OF SAFE USE 3 OPERATIONAL CAUTIONS 4 CERTIFICATION EC Declaration of Conformity ATEX Certificate A A WWW OND A The Centurion XP is a flameproof digital camera suitable for use in hazardous areas Ex zones potentially explosive environments Read and understand all Warnings and Cautions before using this product LIABILITY The technical specification of the camera complies with relevant European EEx standards EN 60079 0 and EN60079 1 The user is solely responsible for ensuring the equipment is suitable for the intended purpose and environments CorDEX Instruments will not be liable for any injury or damage resulting from unauthorized adjustments to or dismantling of the camera or for use with inappropriate applications or environments TRADEMARK INFORMATION Microsoft and Windows are U S registered trademarks of Microsoft Corporation Pentium is a registered trademark of Intel Corporation Macintosh is a trademark of Apple Computer Inc SD is a trademark Other names and products may be trademarks or registered trademarks of their respective owners DEMARK INFORMATION Product design and specifications are subject to change without notice This includes primary specifications software software drivers and user s manual The User Manual is a general reference gui
4. de for the product The manufacturer assumes no liability for any errors or discrepancies in the user manual 2 SPECIAL CONDITIONS OF SAFE USE as defined by clause 29 2 1 of EN 60079 0 3 OPERATIONAL CAUTIONS The conditions referenced in this section relate specifically to hazardous area applications and must be followed In accordance with clause 5 1 of EN 60079 1 the critical dimensions of the flamepaths are Flamepath Maximum Gap mm Minimum L mm Rear catriage tront carriage Front carriage battery pack LOD Window rear carriage Lense window front carriage Operating rod rear and front carriage e This equipment must only be used where there is a low risk of mechanical impact e The equipment is manufactured in aluminium alloy in Group applications this equipment must not be utilised where there is a risk of thermite reaction frictional ignition e The Centurion XP Series digital camera must only be recharged in a non hazardous area e Extreme Care should be taken to ensure that no damage is caused on flamepath between battery and camera Ensure dowel location pins are engaged fully before tightening locking screws e Centurion XP Series digital camera incorporates a protected battery system with a replaceable fuse This Fuse is only to be replaced with CorDEX Instruments Type CDX2341 201 fuse Failure to do so will void the certification e Ensure that the Centurion XP series digital camera battery
5. fidential reports listed in Section 14 2 Compliance with the Essential Health and Safety Requirements with the exception of those listed in the schedule to this certificate has been assured by compliance with the following documents EN 60079 0 2006 EN 60079 1 2007 IEC 60079 0 2007 was used as guidance in respect of marking If the sign X is placed after the certificate number it indicates that the equipment is subject to special conditions for safe use specified in the schedule to this certificate This EC type examination certificate relates only to the design and construction of the specified equipment If applicable further requirements of this Directive apply to the manufacture and supply of this equipment The marking of the equipment shall include the following amp II 2G I M2 Ex d IIC T4 Gb Ex d I Mb Ta 20 C to 50 C Ta 20 C to 50 C Project Number 51A18791 D R Stubbings BA MIET C Index 23 Certification Manager This certificate and its schedules may only be reproduced in its entirety and without change Sira Certification Service Rake Lane Eccleston Chester CH4 9JN England 44 0 1244 670900 Fax 44 0 1244 681330 Email info siracertification com Web www siracertification com

Download Pdf Manuals

image

Related Search

Related Contents

Manuel d`installation et d`utilisation  Samsung T260 Hướng dẫn sử dụng  T'nB USPOP mobile phone case  Supermicro MBD-H8QM8-2+-O  Rexel T70625 folder  Jet Tools JWBS-20 User's Manual  NMDH504_8_16 Manuale Italiano v02  CH-300 製品カタログ  Velleman DCM330 multimeter  Etude de M* ROUCHAS, avoué à Vienne, rue Neuve. PURGE D  