1. Bizehip com enquiry bizchip com SMOKE SENSOR FT 573 Smoke Alarm User s Manual Please read and save this manual 1 Specification 1 110V 240VAC mains power supply 2 Supply voltage DC12 to 30 volts 3 Interconnect up to alarms 4 Photoelectric sensor 5 Two red LED one of button indicate alarm 6 Hush feature to silence nuisance alarm 7 Test button 8 Relay contacts volt free with normally open and normally closed options and rated to 24 volts 1amper resistive 9 High sensitivity 10 Alarm supplied with connector plug for ease of installation built in sounder to give a minimum sound of 85db at 3m smoldering smoke test button simulates smoke use to check performance at least monthly option current 10uUA alarm current 30mA 11 3 years guarantee limited IMPORTANT SAFETY INFORMATION 1 This smoke alarm requires constant 12 30V DC power AC power 110 240 volt This smoke alarm WILL NOT work if the AC power is not connected or has failed or been interrupted for any reason DO NOT connect this smoke alarm to any other type of smoke alarm or auxiliary device except those listed in this manual The test button accurately tests all smoke alarm functions DO NOT use any other test method The smoke alarm weekly to ensure proper operation DO NOT turn off AC power to quiet unwanted alarms This will remove your protection Open windows or fan the air around smoke alarm silence it This smoke alarm should be installed only by licensed q
2. Using the soft brush or wand attachment to a vacuum cleaner vacuum all sides and over of smoke alarm Be sure all vents free debris If necessary turn off power and use a damp cloth to clean the smoke alarm cover IMPORTANT Do not attempt to remove the cover to clean the inside of smoke alarm This will avoid warranty REPAIR CAUTION Do not attempt to repair this smoke alarm Doing this will avoid your warranty If smoke alarm is not operating properly and is still under warranty return smoke alarm to our company Pack it in well padded carton shipping prepaid to If the smoke alarm is not longer under warranty Have a licensed electrician replace the smoke alarm immediately with a comparable our brand smoke alarm PRACTICE FIRE SAFETY If the smoke alarm sounds its alarm horn and you have not pushed the test button it is warning of dangerous situation your immediate response it necessary To prepare for such occurrences develop family escape plans discuss with all household members and practice them regularly 1 Expose everyone to the sound of a smoke alarm and explain what the sound means 2 Determine two exits from each room and an escape route to the outside from each exit 3 Teach all household member to touch the floor to and use an alternate exit if the door is hot instruct them not to open the door is hot 4 Teach all household members to crawl along the floor to stay below dangerous smoke fumes and gases 5 Determine a
3. l smoke alarm with lights or vibrating device to alert occupants 8 Smoke alarm can only sound their alarm when they detect smoke or fire Smoke alarms detect combustion particles or heat in the air They do not sense flame or gas This smoke alarm is designed to give audible warming of a developing fire However many fire area are fast burning explosive or intentional Others are caused by carelessness or safety hazards Smoke may not reach the smoke alarm quickly enough to ensure safe escape 9 Smoke alarm has limitations This smoke alarm is not foolproof and is not warranted to protect lives property from fire Smoke alarms are not a substitute for insurance Homeowners and renters should insure their lives and property In addition it s possible for the smoke alarm to fall at any time for this reason you must test the smoke alarm weekly and replace every 5 years FOR THE BEST PROTECTION WE RECOMMEND THAT YOU INSTALL A SMOKE ALARM IN EVERY ROOM Typical single storey dwelling with recommended Protection see figure1 interconnect sensors see figure 3 Install a smoke alarm on ceiling of wall inside each bedroom and in the hallway out side each separate sleeping area If a bedroom area hallway is more than 30 feet long install a smoke alarm at each end If there a basement install a smoke alarm on the basement ceiling at the button of the stairwell Typical multi storey dwelling with recommended protection Install a smoke alarm o
4. n the ceiling of the wall inside each bedroom and in the hallway outside each separate sleeping area If a bedroom area hallway is more than 30 feet long install a smoke alarm at the top of the first to second floor stairwell Bizchip com enquiry bizchip com IMPORTANT MOKE ALARM PALCEMENT AND EXCEPTION INFORMATION 1 Install a smoke alarm as close to the center of the ceiling as possible If this is no practical mount no closer than 4 inches from a wall or corner Also if local code sallow install smoke alarm on alls between and 12 inches from ceiling wall intersection 2 Install a minimum of two smoke alarms in every home No matter how small the home New construction codes require a minimum of two interconnected smoke alarm in newly build homes Install a smoke alarm in each room that is divided by a partial wall either coming down from then ceiling at least 8 inches or coming up from floor Install a smoke alarm in lived in attics which house electrical equipment like furnaces air conditioners or heaters oo DO NOT INSTALL SMOKE SENSOR ALARMNS Near the appliances or area where normal combustion regularly occurs kitchens near furnaces hot water heaters Use specialized smoke alarm with unwanted alarm control for this area In area with high humidity like bathrooms or areas near dishwashers or washing machines Install all least10 feet away from these areas Near air returns of heating and cooling supply ven
5. safe meeting place for the entire member outside the building WHAT TO DO IN CASE OF FIRE 1 Do not be panic stay calm 2 Leave the building as quickly as possible Touch doors to feel if they are not before opening them Use and alternate exit if necessary Crawl along the floor and do not stop to collect anything 3 Meet at a prearranged meeting place outside the building 4 Call the fire department from outside the building 5 Do not go back to burning building Wait for the fire department to arrive These guidelines will assist you in the event of fire However to reduce the chance that fire safety rules and prevent hazardous situations Bizehip com enquiry bizchip com TROUBLESHOOTING DANGER Always turn off the power at main fuse box or circuit breaker before taking troubleshooting action PROBLEMS SOLUTION Smoke alarm does not sound when tested NOTE Push test button for at least five seconds while testing Remove smoke sensor from mounting plate and check the connector plug is securely attached 2 clean the smoke alarm Smoke alarm beeps about once a minute Re connect the power and clean section Smoke alarm sounds unwanted alarms intermittently or when residents are cooking taking showers heats 1 clean smoke sensor alarm see cleaning in the maintenance and cleaning section The smoke alarm sounds different than it is used to it starts and stops This alarm is opera
6. ting correctly This alarm features the internationally recognized horn signal for evacuation The horn pattern is 3 short Beeps followed by 2 seconds pause and then repeat WARRANTY INFORMATION 3 year limited smoke alarm warranty Company warrants to the original consumer Purchase each new smoke alarm to be free from defects in material and workmanship under normal use and service for a period of 3 years from the date of purchasing This warranty does not cover damage resulting from accident misuse abuse or lack of reasonable care of product In no case shall company be liable for any incidental or consequential damages for breach of this or any other warranty express or implied whatsoever The bad product can be mailed to the following address with a detail explanation of problem There is a jumper at background of smoke sensor that has two functions 1 For closed circuit systems 2 For opened circuit systems Default function is for the closed circuit systems The back of smoke sensor showed above that has four connection pin 1 Signal 2 Signal 3 Negative voltage 4 Positive voltage
7. ts Install at lease 3 feet away from these areas The air could from the detector interrupting its alarm In room where temperatures may fall below 40 F or rise above 100 In extremely dusty dirty or insect infested areas ollse particles interfere with smoke alarm operation _ w oo Se TESTING THE SMOKE ALARM The each smoke alarm to make sure it is installed correctly and operating properly 1 The push to test button accurately tests function Do not uses flame to test this smoke alarm you may ignite and damage the smoke alarm or your house Test smoke alarms weekly and upon returning from vacation or when no one has been in the household for several days Stand at alarm s length from the smoke alarm when resting 2 x 3 x TEST ALL THE SMOKE ALARM WEEKLY BY DOING THE FOLLOWING Firmly depress the push to test button for at least 5 second The smoke alarm will sounds 3 short deeps followed by 2 seconds pause and then repeats The alarm may sound for up it a few of sounds after releasing the push to test button _ DANGER If alarm horn sounds and smoke alarm is not being tested the smoke alarm is sensing smoke or heat THE SOUNDS OF THE ALARM HORN REQURES YOUR IMMEDDIATE ATTENTION AND ACTION TEST ALL THE SMOKE Bizehip com enquiry bizchip com CLEANING Clean the smoke alarm at least once a month to remove dust dirt or debris always turn off the power to smoke alarm before cleaning
8. ualified electrician observe and follow all local and national electrical and building codes for installation This smoke alarm is designed to be used inside a single family or office only in multifamily building each individual living unit should have its own smoke alarm SO NOT install in non residential building And this smoke alarm is not a substitute for a complete alarm system SS o a 2 Bizehip com enquiry bizchip com 6 Install a smoke alarm in every room and on every level of the home Smoke may not reach the smoke alarm for many reasons For example if a fire starts in remote part of the home on another level in a chimney wall roof or on the other side of a closed door smoke many not reach the smoke alarm in time to alert household members A smoke alarm will not promptly detect a fire except in the area or room in which it is installed 7 Smoke alarm may not alert every household member every time The alarm horn is loud in order to alert individuals to a potential danger However there may be limiting circumstances where household members may not hear the alarm i e outdoor or indoor noise sound sleepers drug or alcohol usage the hard to bearing etc if you suspect that this smoke alarm may not alert a household member must hear the alarm s warning sounds and quickly Respond to it to reduce the risk of damage injury or death that may result from fire If a household member is hard of hearing install specia

Download Pdf Manuals

image

Related Search

Datasheet datasheet datasheets 360 datasheet pdf datasheet archive datasheet catalog datasheet esp32 datasheet or data sheet datasheet lm35 datasheet gps module datasheet raspberry pi pico datasheet led datasheet ne555 datasheet dht11 datasheet meaning datasheet 7404 datasheet arduino uno datasheet 2n3904 datasheets for datasets datasheet atmega328p datasheet view access datasheet pic16f877a datasheet hc sr04 datasheet 1n4001 datasheet download datasheet rt6917 circuit diagram