Home
LINEAR BEAM PIXEL SI-043 User Manual
Contents
1. Should you need any spare parts please order genuine parts from your local dealer PLL CE LINEAR BEAM PIXEL SI 043 User Manual KEEP THIS MANUAL FOR FUTURE NEEDS 1 Unpacking Thank you for choosing Color Imagination s LINEAR BEAM PIXEL For your own safety please read this manual before installing the device This manual covers the important information on installation and applications Please install and operate the fixture with following instructions Meanwhile please keep this manual well for future needs Color Imagination s LINEAR BEAM PIXEL is made of a new type of high temperature strength of engineering plastics and cast aluminum casing with nice outlook The fixture is designed and manufactured strictly following CE standards complying with international standard DMX512 protocol It s available independently controlled and linkable with each other for operation And it is applicable for small to medium live performances theater studio nightclubs and discos SI 043 adopts 8PCS high power 8W White LEDs which features high brightness and stability Please carefully unpack it when you receive the fixture and check whether it is damaged during the transportation And please check whether the following items are included inside the box LINEAR BEAM PIXEL One Signal Cable One Omega Clamp Two Power Cable One Safety Chain One User Manual One 9 Key Fea
2. 11 Maintenance and Cleaning The following points have to be considered during the inspection 1 All screws for installing the devices or parts of the device have to be tightly connected and must not be corroded 2 There must not be any deformations on the housing color lenses fixations and installation spots ceiling suspension trussing 3 Mechanically moved parts must not show any traces of wearing and must not rotate with unbalances 4 The electric power supply cables must not show any damage material fatigue or sediments Further instructions depending on the installation spot and usage have to be adhered by a skilled installer and any safety problems have to be removed CAUTION Disconnect from mains before starting maintenance operation In order to make the lights in good condition and extend the life time we suggest a regular cleaning to the lights 1 Clean the inside and outside lens each week to avoid the weakneness of the lights due to accumulation of dust 2 Clean the fan each week 3 Adetailed electric check by approved electrical engineer each three month make sure that the circuit contacts are in good condition prevent the poor contact of circuit from overheating We recommend a frequent cleaning of the device Please use a moist lint free cloth Never use alcohol or solvents There are no serviceable parts inside the device Please refer to the instructions under Installation instructions
3. X address setting ADDR SLAV ON OFF SLAV Set to slave ALON AU A Running built in program alone AUTO IP1 8 MAST AU M Set to master Auto running ALON SO A Set to sound control alone SOUN IP1 8 w fw o MIC LODA ON OFF V 1 0 V 9 9 a 14 DMX channel mode REST ON OFF All reset
4. able materials decoration etc Always use and install the supplied safety cable as a safety measure to prevent accidental damage and or injury in the event the clamp fails Mounting points Overhead mounting requires extensive experience including amongst others calculating working load limits a fine knowledge of the installation material being used and periodic safety inspection of all installation material and the fixture If you lack these qualifications do not attempt the installation yourself Improper installation can result in bodily injury Be sure to complete all rigging and installation procedures before connecting the main power cord to the appropriate wall outlet Clamp Mounting The LINEAR BEAM PIXEL provides two unique mounting brackets assembly that integrates the bottom of the base the included Omega Bracket and the safety cable rigging point in one unit see the illustration below When mounting this fixture to truss be sure to secure an appropriately rated clamp to the included omega bracket using a M10 screw fitted through the center hole of the omega bracket As an added safety measure be sure to attached at least one properly rated safety cable to the fixture using on of the safety cable rigging point integrated in the base assembly Regardless of the rigging option you choose for your LINEAR BEAM PIXEL always be sure to secure your fixture with a safety cable The fixture provides a built in rigging point
5. ctions and warning notes written in this user manual Ze Important Damages caused by the disregard of this user manual are not subject to warranty The dealer will not accept liability for any resulting defects or problems If the device has been exposed to temperature changes due to environmental changes do not switch it on immediately The arising condensation could damage the device Leave the device switched off until it has reached room temperature This device falls under protection class Therefore it is essential that the device be earthed The electric connection must carry out by qualified person The device shall only be used with rate voltage and frequency Make sure that the available voltage is not higher than stated at the end of this manual Make sure the power cord is never crimped or damaged by sharp edges If this would be the case replacement of the cable must be done by an authorized dealer Always disconnect from the mains when the device is not in use or before cleaning it Only handle the power cord by the plug Never pull out the plug by tugging the power cord During initial start up some smoke or smell may arise This is a normal process and does not necessarily mean that the device is defective it should decrease gradually Please don t project the beam onto combustible substances Fixtures cannot be installed on combustible substances keep more than 50cm distance with wall for smooth air flow so there
6. ent is needed Don t try to change the fixtures without any instruction by the manufacturer or the appointed repairing agencies lt is not in warranty range if there are any malfunctions from not following the user manual to operate or any illegal operation like shock short circuit electronic shock lamp broke etc 4 Mounting and Installation Cautions For added protection mount the fixtures in areas outside walking paths seating areas or in areas were the fixture might be reached by unauthorized personnel Before mounting the fixture to any surface make sure that the installation area can hold a minimum point load of 10 times the device s weight Fixture installation must always be secured with a secondary safety attachment such as an appropriate safety cable Never stand directly below the device when mounting removing or servicing the fixture 8 DMX Channels Freon ewe Deep MOD1 MOD 2 1 2 Po ate ir arenes Stet ae ae Pixel 1 saturation control Pixel 1 saturation control 0 100 100 e o maa oas reorononoo o e mas oas renon o o mea ozs nerona 7 Photometric Data Photometric Beam Angle Data 2 Beam Angle LUX x 0 0929 FC 1LED 6968FC 75000LUX 920FC 9900LUX 307FC 3300LUX 165FC 1770LUX 22 96 ft 2 Beam Angle from a ceiling or set on a flat level surface see illustration below Be sure this fixture is kept at least 0 5m 1 5 ft away from any flamm
7. for a safety cable on the hanging bracket as illustrated above Be sure to only use the designated rigging point for the safety cable and never secure a safety cable to a carrying handle 5 DMX 512 control connections Connect the provided XLR cable to the female 3 pin XLR output of your controller and the other side to the male 3 pin XLR input of the moving head You can chain multiple Moving head together through serial linking The cable needed should be two core screened cable with XLR input and output connectors Please refer to the diagram below DMX 512 connection with DMX terminator xy 120 ohm CONTROLLER AC 90 260V 50 60Hz DMX Output DMX Input 3 Pin XLR Socket 3 Pin XLR Socket COMMON 2 Data DMX512 OUT DMX512 IN 3 Data 3PIN XLR J we N 3 PIN XLA For installations where the DMX cable has to run a long distance or is in an electrically noisy environment such as in a discotheque it is recommended to use a DMX terminator This helps in preventing corruption of the digital control signal by electrical noise The DMX terminator is simply an XLR plug with a 120 Q resistor connected between pins 2 and 3 which is then plugged into the output XLR socket of the last fixture in the chain Please see illustrations below 120 2 3 1 PIN3 PIN 2 6 Menu Operations VALU A001 AXXX AXXX DM
8. should be no shelter for fans and ventilation for heat radiation If the external flexible cable or cord of this luminaire is damaged it shall be exclusively replaced by the manufacturer or his service agent or a similar qualified person in order to avoid a hazard 3 Operation Instructions The LINEAR BEAM PIXEL is for beam effect for on site decoration purpose Don t turn on the fixture if it s been through severe temperature difference like after transportation because it might damage the light due to the environment changes So make sure to operate the fixture until it is in normal temperature This light should be keep away from strong shaking during any transportation or movement Don t pull up the light by only the head or it might cause damages to the mechanical parts Don t expose the fixture in overheat moisture or environment with too much dust when installing it And don t lay any power cables on the floor Or it might cause electronic shock to the people Make sure the installation place is in good safety condition before installing the fixture Make sure to put the safety chain and check whether the screws are screwed properly when installing the fixture Make sure the lens are in good condition It s recommended to replace the units if there are any damages or severe scratch Make sure the fixture is operated by qualified personnel who knows the fixture before using Keep the original packages if any second shipm
9. tures 8PCS 8W high power WHITE LEDs 100 000 hours lifespan and low power consumption 8 pixels each LED is a pixel controllable individually Outstanding white BEAM effect Specific optic system High light output with 4870LUX 7M for 8 BEAMs 1770LUX 7M for 1 BEAM High efficiency LED shutter Strobe effect with 18 flashes per second and pulse effect 0 100 smooth linear dimmer Amazing streaming effect 8 built in default programs for easy performance 12 default pixel macros effect 14 15 DMX channels DMX512 master slave and sound activated controllable or auto operation LED display Efficient Noise free aluminum cooling system Powercon IN OUT as default 3 pin XLR connectors Two 1 4 turn fastening Omega Clamps 10 Technical Specifications Input Voltage AC90 260V 50 60Hz LED Quantities 8PCS 8W WHITE LEDs Control Signal DMX512 master slave and sound activated or auto operation Control Channel 14 15 DMX Channels switchable Power Consumption 120W Dimensions 84 D x1064 W x180 H mm Packing Dimensions 165 D x1165 W x220 H mm Net Weight 7 5kg Gross Weight 10kg 2 Safety Instructions l CAUTION Be careful with your operations With a dangerous voltage you can Suffer a dangerous electric shock when touching wires This device has left the factory in perfect condition In order to maintain this condition and to ensure a safe operation it is absolutely necessary for the user to follow the safety instru
Download Pdf Manuals
Related Search
Related Contents
Manual de Usuario UPO33PF365 MAQUINAD EHUMO - CLOUD 1000 MANUAL DE INSTRUCCIONES RCC de Delta Tau PMAC2 User's Manual Copyright © All rights reserved.